ML17037C759
| ML17037C759 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 02/06/2017 |
| From: | Niagara Mohawk Power Corp |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML17037C759 (1) | |
Text
NMPNS-2 TABLE 7,2-1 (CONT'D)
DES 13.
Abbreviations used in table:
AO Air operated MO Motor operated SO
- Solenoid operated RHR
- Residual Heat Removal System LPCI - Low Pressure Coolant Injection System RCIC - Reactor Core Isolation Cooling System LPCS - Low Pressure Core Spray System HPCS High Pressure Core Spray System
~inal DDDt
'eactor vessel low water level (A scram will occur at this level also.
This is the higher of the two low water level signals)
Reactor vessel low water level (The reactor core isolation cooling system willbe initiated at this, level s1so.
This ie the lower of the two low water level signals.)
High radiation - main steam line Line break main steam line (high steam flow)
Line break main steam line (steam line high space temperature)
High dry well pressure Reactor vessel low water level or high dry well pressure (core standby cooling systems will be-started)
High reactor water level in startup mode Line break in cleanup system high space temperature; high.differential flow N
Line break in reactor core isolation cooling system steam line to turbine (high steam line space temperature, high steam flow, or low steam line pressure)
Line break in residual heat removal system shutdown and head cooling (high space temperature)
Reactor high water level p+
R S
Low main steam line pressure at inlet to turbine (RUN mode only)
Low condenser vacuum Low dry well pressure U
High reactor vessel pressure
- close residual heat removal shutdown cooling valves and head cooling valves High temperature at outlet of cleanup system nonregenerative heat exchanger, high differential flow, high area temperatureS Standby liquid. control system actuated High radiation, Refueling floor exhaust, Remote manual switch from control room.
(All regular Group A and Group B isolation valves will be capable of remote manual operation from the control room.)
These are the isolation functions of the primary containment and reactor vessel rsolation control system; other functions are given for information only.
6of6