Text
NRC DIS RIBUTION FOR PART 50 DOCKET ERIAL (TEMPORARY FORM)
CONTROL NO:
FILE' ROM. LeBoeuf,Lamb,Leiby & MacR Washingtori, D
C LeBoruf Lamb Leib &MacRae 9>>2-75 9-2-75 DATE OF DOC DATE REC'D LTR XXX TWX RPT OTHER TO:
Ben C, Rusche ORIG 3 Signed CC OTHER SENTNRC PDR SENT LOCAL PDR CLASS UNCLASS PROPINFO XXXX DESCRIPTION:
INPUT NO CYS REC'D 3
ENCLOSURES DOCKET NOe 50-220 N otarized ltr. 8-29-75,
~ ~ trans the follow ingo. ~.e I
PLANT NAME:
Nine Mile Point '$.i Propos'ed Amdt.
to 0/L change to Tech Spec; con-sisting of Revisions to ChangeMinimum Critical P'ower Ratio, ~ ~.Attach."B"-Rod Withdrawal Error Transient Analysis. ~ ~,W/Pigs. ~,'
Certificate of Service "Application for Amdt to Opert. Lic." served yupon Mr, Robert P."Jones Supervisor, Town of Scriba,R,D.
(f4, Osewege,:N.Y.';>>
et al ~ ~ ~ ~ ~ ~
.( 40 cys, Rec'd).
/
FOR ACTION/INFORMATION VCR 9-4-75 BUTLER (L)
W/ Copies CLARK (L)
W/ Copies PARR (L)
W/ Copies KNIEL {L)
W/ Copies SCHWE NCE R (L)
Z I EMANN {L)
R EG AN (E)
W/ Copies W/ Copies W/ Copies STOLZ (L)
DICKER (E)
WEAR (L)
W/ Copies W/ Copies w//poppies KNOWLEDGED
)/ASSALLO (L)
KNIGHTON (E)
SPZES QC W/ Copies W/ Copies PURPLE (L)
YOUNGBLOOD (E)
LPM W/ Copies W/ Copies W/
op(es INTERNALDISTRIBUTION AlRC PDR
~GC, ROOM P-506A
~OSSI CK/STAF F CASE G IAMBUSSO BOYD MOORE (L)
DEYOUNG (L)
SKOVHOLT (L)
GOLLER {L) {Ltr)
P. COLLINS D NISE EG QPR FILE 5 REGION (2)
HIPC TECH REVIEW SCHROEDER MACCARY KNIG HT PAWLICKI SHAO STE LLO HOUSTON NOVAK ROSS IPPO LITO TEDESCO J,COLLINS LAINAS BENAROYA VOLI MER DENTON GRIMES CiAMM ILL KASTNER BALLARD SPANGLER ENVIRO MULLER DICKER KNIGHTON YOUNGBLOOD REGAN PR ECT DR HARLESS LIC ASST R. DIGGS (L)
H. GEARIN (L)
E. GOULBOURNE {L)
P. KR E UTZE R (E)
J. LEE (L)
M.RU3HBROOK(L)
S. REED {E)
M. SERVICE {L)
S. SHEPPARD (L)
M. SLATER (E)
H. SMITH {L)
~. TEETS {L)
G. WILLIAMS(E)
V. WILSON (L)
R. INGRAM (L)
M. DUNCAN A/T I ND
~
8 RAITMAN SALTZMAN MELTZ PLANS MCDONALD CHAPMAN DUBE (Ltr)
E. COUPE PETERSON HARTFIELD (2)
KLECKER EISENHUT WlGG INTON
/
rt EXTERNAL'DISTRIBUTION R LOCALPDR A TIC (ABERNATHY)
(
(2){10) ATIONALLABS v
1 NSIC (BUCHANAN) 1 W. PENNINGTON, Rm E-201 GT 1 ASLB CONSULTANTS 1 Newton Anderson NEWMARK/BLUME/AGBABIAN lk)- AORS See QS/SENT
/
1 PD R-SAN/LA/NY 1 BROOKHAVENNAT LAB 1 G. ULRIKSON ORNL
I E
E
~
~
~
~
~
~
~
~
4
~
~ 4
~
~
~
~
~ 4 4 4
~
~
'RaReatqrg ARVIN E. VIaTON LEONARD M. TROSTKN WILLIAMO. DOUB EUGENE B. THOMAStJR.
HARRY H ~ VOIGT L. MANNING MLINTZING LEX K. LARSON HENRY V. NICKEL WASHIHOTDH PARTHEHS September 2,
19.75 aalktwa a yg t la+
II 4HIIIa
~gnfTCB II; IIgp+
Mr. Ben C.
Rusche Director Office of Nuclear Reactor Regulation U.S; Nuclear Regulatory Commission Nashington, D.C.
20555 SM9II %et~
LAW orrICES or LEBOEUF, LAMB,LEIBY8 MACRAE l757 N STREET. N. W, WAsHINGTQN,D. C. 20036 I40 BROADWAY NEW YORK'.Y. IOOO5
- WASHINGTON TELEIaNDNE 202 872-8888 CABLE ADDRESS LALALU,WAS H IN GTO N D. C, TELEX: 440274 Re:
Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Unit No, 1
Dock'et No.
50'-'220'ear Mr. Rusche:
Transmitted herewith are three (3) signed originals and nineteen (19) copies of a document entitled "Application for Amendment to Operating License."
This Application seeks to amend Section 3.1.7c of the Technical Specifications set forth in Appendix A to Facility Operating License No, DPR-63 to change the Minimum Critical Power Ratio from 1.24 to 1.25.
Forty (40) copies of the proposed, change in Technical Speci-fications and safety evaluation accompany this Application.
A Certificate of Service showing service of these documents upon the persons listed therein is also enclosed.
Very truly yours,
- LeBoeuf, Lamb, Leiby NacRae Attorneys for Niagara Mohawk Power Corporati.on
~ t k
~
J
".)ae,& I <<{
W.)
a s
~e.
BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION
, Xn the Matter of
)
)
NIAGARA MOHAWK POWER CORPORATION
)
(Nine Mile Point Nuclear Station
)
Unit No.
1)
)
Docket No. 50-220 CERTIFICATE OF SERVICE I hereby certify that X have served.
a document entitled "Application for Amendment to Operating License" by mailing a copy thereof first class, postage
- prepaid, to the following persons this 2nd day of September, 1975.
Mr. Robert P. Jones Supervisor Town of Scriba R.
D.
54
- Oswego, New York 13126 Miss Juanita Kersey Librarian Oswego City Library 120 E.
Second Street
- Oswego, New York 13126 Dr. William E.
Seymour Staff Coordinator New York State Atomic Energy Council New York State Department of Commerce 99 Washington Avenue
- Albany, New York 12210 Hop M. Babcock
- LeBoeuf, Lamb, Leiby 6 MacRae Attorneys for Applicant
)
,I
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
NIAGARA MOHAWK POWER CORPORATION)
(Nine Mile Point Nuclear Station)
Unit No.
1)
)
Docket No. 50-220 J
APPLICATION FOR 'AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the Nuclear Regulatory Commission, Niagara Mohawk Power Corporation, holder of Facility Operating License No. DPR-63, hereby requests that Section 3.1.7c of the Technical Specifications set forth in Appendix A to that License be amended.
This change is provided in response to the August 14, 1975 letter of request from Hr.
George Lear to Mr. G.
K. Rhode.
This proposed change has been approved by the Site Operations Review Committee and Safety Review and Audit Board.
14 I
M
--2-"
The proposed technical specification change is set forth in Attachment A to this application.
The Licensee also transmits as Attachment B a document entitled, "Rod Withdrawal Error Transient Analysis."
The proposed change would not authorize any change in the types or any increase in the amounts of effluents or any increase in the authorized power level of the facility.
WHEREFORE, Appl icant respectfully requests that Appendix A to Facility Operating License No.
DPR-63 be amended in the form attached hereto as Attachment A.
NIAGARA MOHAWK POWER CORPORATION Gera ld K. Rhode Vice President-Engineering Subscribed and sworn to before me on this'-f day of August, 1975.
Nota y Publtc HAZEL 'J. CARRICK, Notary Pohiic in the Stato of Ncw York Qualified in Onon. Co. No. 4524460
.uy Co:<<<< I>> ion Expire>> MarCh 30,I9 7 to
0 l
C I
l
ATTACHMENT A Niagara Mohawk Power Corporation License No.
DPR"63 Docket No. 50"220 Proposed Change to Technical Specifications I tern Loca t ion"-
Chanche Limiting Condition for Operation 3.l.jc Page 64a Change Minimum Critical Power Ratio (MCPR) value for 8 x 8 fuel to "> 1.25"
<'he June 27, 1975 "Application of General Electric Thermal Analysis Basis (GETAB)"
submittal proposed the addition of page 64a to the Technical Specifications.
ATTACHMENT B Nine Mile Point Unit 1 Nuclear Power Station Rod Mithdrawal Error Transient Analysis (Supplement to "Application of General Electric Thermal Analysis Basis (GETAB)," June'975)
August 1975
I.
Introduction This report presents the results of an analysis of the rod withdrawal error transient for Cycle 3.
This information is provided in response to Reference 1 and supplements that in Reference 2.
II.
Anal sis of Rod Withdrawal Error Transient Discussion of the rod withdrawal error transient analysis, including assumptions, is presented in Sections 6.2.4 and 6.3.3.2 of Reference 3.
A description of input to this analysis is presented in Section IV of Attachment B to Reference 2.
With the rod block setting at
- 1054, the Cycle 3 rod block response is shown'in Figures 24 and 25 of Reference 4.
The worst case HCPR at rod block is determined from the attached Figures 1 and 2.
As a result of this analysis, it is necessary that the 8 x 8 HCPR operating limit be increased to 1.25, in order to avoid violating the HCPR Safety Limit during a postulated rod wlthdrawal error transient.
.10
.05 0.0 Bundle Location (19,34)
-.05
-.10 Bundle Location (11,34)
.15
-.20
-.25 NOTE:
0.0 corresponds to 8x8 MCPR operating limit
-. 30 12 16 20 NOTCH POSITION OF TRANSIENT ROD (OUT) 24 28 32 Figure 1.
NhP-1 Cycle 3 Notch Position of Transient Rod versus
~MCPR for 7x7 Fuel
~y
~.
.1
.05 0.0
-0.5 Bundle Location (13,34)
CC cl Bundle Location (17,34)
-.15 2
-.25 NOTE:
0.0 corresponds to 8x8 MCPR operating limit
-.30 0
8 12 16 20 24 28 32 NOTCH POSlTION OF TRANSIENT ROD (OUT)
Figure 2.
NMP-1 Cycle 3 Notch Position of Transient Rod versus hMCPR for 8x8 Fuel
fs
~ g
REFERENCES 1.
Letter from Mr. G. Lear (Nuclear Regulatory Commi ss ion) to Mr.
G.
K. Rhode (Niagara Mohawk), August 14, 1975.
2.
Niagara Mohawk Power Corporation to United States Nuclear Regulatory Commission, "Application for Amendment to Technical Specifications,"
June 27, 1975.
3.
GE/BWR Generic Reload Application for 8 x 8 Fuel, Supplement 2, May, 1975 (NED0-20360).
4.
Letter from Mr. P.
D.
Raymond (Niagara Mohawk) to Mr. A.
Giambusso (Atomic Energy Commission) dated October 15, 1973.
~-
E
~ ~
gl I