Forwards Safety Evaluation Granting one-time 60-day Extension for Performance of Visual Insp for Leakage on Containment Spray,Safety Injection,Nitrogen & Component Cooling Water Sys
ML16341F323
Person / Time
Site: Diablo Canyon 
Issue date: 09/07/1989
From: Knighton G
Office of Nuclear Reactor Regulation
To: Shiffer J
PACIFIC GAS & ELECTRIC CO.
Shared Package
ML16341F324 List:
References
NUDOCS 8909210069
Download: ML16341F323 (12)


Text

September 7,

1989 Docket Nos.

50-275 and 50-323 DISTRIBUTION navrrl ~

~NRC-5-LPDRs PD5 Reading MVirgilio JLee RBevan HRood OGC DHagan EJordan TMeek (8)

Wanda Jones JCalvo ACRS (10)

GPA/PA OC/LFMB Region V (4)

RHermann Mr. J.

D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Francisco, California 94106

Dear Mr. Shiffer:

SUBJECT:

SCHEDULAR RELIEF FROM CERTAIN INSERVICE INSPECTION RE(UIREMENTS-DIABLO CANYON POWER PLANT The staff has completed its review of your schedular relief request dated September 5

1989.

The request is for one-time relief for Diablo Canyon Power Plant (DCPP Unit 1, a 60-day extension for the performance of a visual inspection for leakage at maximum expected system pressure on the Containment Spray, Safety Injection, Nitrogen, and Component Cooling Water systems, as identified in Tables IWC-2500-1, Item C 7.20 and IWD-2500-1, Item D 3.1 of the ASME Code,Section XI, and the Inservice Inspection Program (ISIP) for DCPP.

The one-time schedular relief requested for inspection of the affected piping and welds is granted.

A copy of the related safety evaluation is enclosed.

S incerely,

/s/

Written relief may be granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i).

Our review has determined that the granting of relief is authorized by law, will not present an undue risk to the public health and safety, will not endanger life or property and is consistent with the common defense and security, and is otherwise in the public interest giving due consideration to the burden on the licensee that could result if the require-ments were imposed upon the facility.

Therefore, the visual inspections for leakage at maximum expected system pressure on the systems previously designated will be deferred for 60 days beyond September 7,

1989 and will be performed during the upcoming Unit 1 third refueling outage, currently scheduled to begin October 13, 1989, or whenever Unit 1 is brought to Mode 5 if that occurs before the refueling outage begins.

8909210069 8/0907 PDR ADOCK 0 000275 PDC

Enclosure:

Safety Evaluation cc:

See next page

  • See previous concurrence George W. Knighton, Director Project Directorate V

Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation 3%f l (

DRSP/PD5 JLee*

9/7/89 DRSP/PD5 RBevan:dr*

9/7/89 NRR/EMTB CYCheng*

9/7/89 DRSP/D:PD5 GKnighton*

9/7/89 OGC STurk" 9/7/89 (A)AD:DRSP35 MVirgi lio*

9/7/89

t It I

(

~

I (l I

(

l

(

I 4

~

'I I

HPKI>I

('II w

w w

I w

e 4

w

(

l,tl (,J Ma

'4.'t It w

~

(

~ k a

~ w 4

4 h I

'I I

a w ~

lk>K.

4 I w Ma'VMMl t

t fl l /I'I w

IC Ma w

y w

'w If

'I 4 I

W

>II 4 l

ttl N

4 w

I ll I

M a<<y kr ~

I ka44 4

w a

I a,

M>l wa w

4 4,

w HKM wl >>air a

,ft "I "'ll w

II> r lily l k ww'J, w

4 l(M 4 4

4 wk 4 I

'I 4

4

~

K,,a>i w

w f

aywM 4

I al tl a

w

,I, ~

W I It tt lw w

(l 4, '

Wrw la

~ HMwy 4

w

' r

~

Docket Nos.

50-275 and 50-323 Mr. J.

D. Shiffer, Vice President Nuclear Power Generation c/o Nuc1 ear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Francisco, California 94106

Dear Mr. Shiffer:

SUBJECT:

SCHEDULAR RELIEF FROM CERTAIN POWER PLANT DISTRIBUTION EJordan NRC 5 LPDRs TMeek (8)

PD5 Reading Wanda Jones MVirgilio JCalvo JLee ACRS (10)'Bevan GPA/PA HRood OC/LFMB OGC Region V (4)

DHagan RHermann INPSECTION REQUIREME TS - DIABLO CANYON The staff has completed its review of your schedular relief request dated September 5

1989.

The request is for one-time relic/ffor Diablo Canyon Power Plant (DCPP Unit 1, a 68-day extension for the performance of a visual inspection for leakage at maximum expected system pressure on the Containment Spray, Safety Injection, Nitrogen, and Component~Cooling Water systems, as identified in Tables IWC-2500-1, Item C 7.20 and IWD-2500-1, Item D 3.1 of the ASME Code,Section XI, and the Inservice Inspection Program (ISIP) for DCPP.

Written relief may be granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i).

Our review has determined that the granting of relief is authorized by law, will not present an undue risk to the public health and safety, will not endanger life or property and is consistent with the common defense and security, and is otherwise in the public interest giving due consideration to the burden on the 1'icensee that could result if the require-ments were imposed upon the facili>ty.

Therefore, the visual inspections for leakage at maximum expected system pressure on the systems previously designated will be deferred for 68 days bey'ond September 7,

1989 and wi'll be performed during the upcoming Unit I third refueling outage, currently scheduled to begin October 13, 1989, or whenever Unit I is brought to Mode 5 if that occurs before the refueling outage begins~

The one-time schedular re'lief requested for inspection of the affected piping and welds is granted.

A copy of the related safety evaluation is enclosed.

Sincerely, Enclosu e:

Safety Evaluation George W. Knighton, Director Project Directorate V

Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear 'Reactor Regulation 9

/89 cc:

See next page

  • See previous concurrence P/PD5 DRSP/PD5 RBevan:dr*

9/7/89 NRR/EMTB CYCheng*

9/7/89 DR

PD5 G

ton*

9/7/89 OGC STurk" 9/7/89 (A)AD:DRSP35 yw'Virgi 1 io "1"'

(g,ll H

Docket Nos. 50-275 and 50-323 Mr. J.

D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Franci sco, Ca 1 ifor nia 94106 DISTRIBUTION oce re NRC

& LPDRs PD5 Reading MVirgi 1 io JLee RBevan HRood OGC DHagan EJordan TMeek (8)

Wanda Jones JCalvo ACRS (10)

GPA/PA OC/LFMB Region V ('4)

RHerman

Dear Mr. Shiffer:

SUBJECT:

SCHEDULAR RELIEF FROM CERTAIN INPSECTION REQUIREMENTS - DIABLO CANYON POWER PLANT The staff has completed its review of your schedular relief rp uest dated September 5

1989.

The request is for one-time relief for Diablo Canyon Power Plant (DCPPI Unit 1, a 60-day extension for the performance of a visual inspection for leakage at maximum expected system pressure on the Containment Spray, Safety Injection, Nitrogen, and Component Cooliyg Water systems, as identified in Tables IWC-2500-1, Item C 7.20 and IWDQ500-1, Item D 3.1 of the ASME Code,Section XI, and the Inservice Inspectio

~program (ISIP) for DCPP.

In accordance with Technical Specification 4.0.$

written relief may be granted by the Coamission pursuant to 10 CFR 50.55a(g)(6 (I).

Our review has determined that the granting of relief is authorized bylaw, wi 11 not present an undue risk to the public health and safety, and js consistent with the common defense and security, giving due consideration to~the burden on the licensee that could result if the requirements were imposed/upon the facility Th.erefore, the visual inspections for leakage at maximum expected system pressure on the systems previously designated will bd deferred for 60 days beyond September 7,

1989 and will be performed during PIIe upcoming Unit I third refueling outage, currently scheduled to -begin Oct ber 13, 1989, or whenever Unit I is brought to Mode 5 if that occurs befor the refueling outage begins.

The one-time schedular relic requested for inspection of the affected piping and welds is granted.

A copy of the related safety evaluation is enclosed.

S incere ly, Enclosure.

Safety valuation cc: ~See next page

  • Se previous concurrence George W. Knighton, Director Project Directorate V

Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation

/PD5 9/

/89 DRSP/PD5 RBevan:dr*

9/7/89 NRR/EMTB CYCheng*

9/7/89 DRSP/D:PD5 GKnighton*

9/7/89

~0~

(A)AD:DRSP35 MVirgilio 9/

/89 9/

/89

Y

/

~

~

Docket Nos. 50-275 and 50-323 Hr. J.

D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Francisco, California 94106 DISTRIBUTION NRC 8

LPDRs PD5 Reading MVirgilio JLee RBevan HRood OGC DHagan EJordan THeek (8)

Wanda Jone JCalvo ACRS (10')

GPA/Pg OC/LCM B Region V (4)

H'ermann

Dear Hr. Shiffer:

SUBJECT:

RELIEF FROM INSERVICE INSPECTION RE UIREMENTS The staff has completed its review of your schedular relief request dated September 5

1989.

The request is for one-time relief for Oiablo Canyon Power Plant (OCPP Unit 1, a 60-day extension for the performance of a visual inspection for. leakage at maximum expected system pressure on the Containment Spray, Safety Injection, Nitrogen, and Component Cooling Water systems, as identified in Tables IWC-2500-1, Item C 7.20 and W0-2500-1, Item D 3.1 of the ASRE Code,Section XI, and the Inservice Inspection Program (ISIP) for OCPP.

In accordance with Technical Specification 4.9.5 written relief may be granted by the Commission pursuant to 10 CFR 50.55a(,i()(6I(1).

Our review has determined that the granting of relief is authorized P$'aw and will not endanger life or property or the common defense and securiPP, and is otherwise in the public interest, giving due consideration to t)e burden on the licensee that could result if the requirements were imposed upon the facility.

Therefore, the visual inspections for leakage at maximum expected system pressure on the systems previously designated wil! l(e deferred for 60 days beyond September 7,

1989 and will be performed during the upcoming Unit 1 third refueling outage, currently scheduled to begin October 13, 1989, or whenever Unit 1 is brought to Mode 5 if that occurs before'he refueling outage begins.

/'he one-time schedular relief requested for inspection of the affected piping and welds is granted.

A copy of the related safety evaluation is enclosed.

Sincerely, Enclosure.

Safety kaluation cc:

See next page George W. Knighton, Director Project Directorate V

Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation DRSP/PD5 p~SP/PD5 Zy JLee MHevan:dr 9/

/89 9/1 /89 EHTB 9/7 9

D

'PD5 A)AD:DRSP35 hton MVirgilio 9/,

/89 9/

/89 9/

/89

K

)f k

lt t'

r

gp,4 4606 C~

P~

ss i~..

vf o

s

~O sp*~*qs O

UNITED STATES NUCLEAR R EG ULATORY COMMISSION WASHINGTON, D. C. 20555 September 7,

1989 Docket No. 50-275 Mr. J.

D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Franci sco, California 94106

Dear Mr. Shiffer:

SUBJECT:

SCHEDULAR RELIEF FROM CERTAIN INSERVICE INSPECTION REQUIREMENTS-DIABLO CANYON POWER PLANT The staff has completed its review of your schedular relief request dated September 6

lggg.

The request is for one-time relief for Diablo Canyon Power Plant (DCPP Unit 1, a 60-day extension for the performance of a visual inspection for leakage at maximum expected system pressure on the Containment Spray, Safety Injection, Nitrogen, and Component Cooling Water systems, as identified in Tables IWC-2500-1, Item C 7.20 and IWD-2500-1, Item D 3.1 of the ASME Code,Section XI, and the Inservice Inspection Program (ISIP) for DCPP.

Written relief may be granted by the Comission pursuant to 10 CFR 50.55a(g)(6)(i).

Our review has determined that the granting of relief is authorized by law, will not present an undue risk to the public health and safety, will not endanger life or property and is consistent with the common defense and security, and is otherwise in the public interest giving due consideration to the burden on the licensee that could result if the require-ments were imposed upon the facility.

Therefore, the visual inspections for leakage at maximum expected system pressure on the systems previously designated will be deferred for 60 days beyond September 7,

1989 and will be performed during the upcoming Unit 1 third refueling outage, currently scheduled to begin October 13, 1989, or whenever Unit 1 is brought to Mode 5 if that occurs before the refueling outage begins.

The one-time schedular relief requested for inspection of the affected piping and welds is granted.

A copy of the related safety evaluation is enclosed.

S incere ly,

Enclosure:

Safety Evaluation George

. Knighton, irector Project Directorate V

Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc:

See next page

Mr. J.

D. Shiffer Paci fic Gas and E 1ectri c Company Diablo Canyon CC:

NRC Resident Inspector Diablo Canyon Nuclear Power Plant c/o U.S. Nuclear Regulatory Commission P. 0.

Box '369 Avila Beach, California 93424 Dr.

R.

B. Ferguson Sierra CLub - Santa Lucia Chapter Rocky Canyon Star Route Company Creston, California 93432 Ms. Sandra A. Silver 660 Granite Creek Road Santa Cruz, California 95065 Bruce Norton, Exq.

c/o Richard F. Locke, Esq.

P. 0.

Box 7442 San Franc isco, Ca liforni a 94120 Managing Editor The Count Tele ram Tribune 1321 Jo nson Avenue P. 0.

Box 112 San Luis Obispo, California 93406 Chairman San Luis Obispo County Board of Supervisors Room 270 County Government Center San Luis Obispo, California 93408 Richard F. Locke, Esq.

Pacif ic Gas 8

E 1 ectri c Company Post Office Box 7442 San Franci sco, Cal ifornia 94120 Hr. John Hickman Senior Kealth Physicist Environmental Radioactive Hgmt. Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Regional Adminstrator, Region Y

U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Hr. Peter H.

Kaufman Deputy Attorney General State of California 110 West A Street, Suite 700 San Diego, California 92101 Ms.

Nancy Culver 192 Luneta Street San Luis Obispo, California 93401 Michael M. Strumwasser, Esq.

Special Assistant Attorney General

'tate of California Department of Justice 3580 Wilshire Boulevard, Room 800 Los Angeles, California 90010