I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:16.1Table:3.2.1-1 Page:1 of 3INITIAL CORE MECHANICAL DESIGN PARAMETERS 1(ALL DIMENSIONS ARE FOR COLD CONDITIONS.)Active Portion of the CoreEquivalent Diameter, in.132.7Active Fuel Height, in.Region 1144.0Region 2 143.4Region 3142.8Length-to-Diameter Ratio 1.09Total Cross-Section Area, Ft 2 96.06Fuel AssembliesNumber193Rod Array15 x 15Rods per Assembly204 1Rod Pitch, in.
0.563Overall Dimensions8.426 x 8.426Fuel Weight, (as UO 2), pounds219,900Total Weight, pounds279,000Number of Grids per Assembly 7Number of Guide Thimbles20Diameter of Guide Thimbles (upper part), in.0.545 O.D. x 0.515 I.D.Diameter of Guide Thimbles (lower part), in.0.484 O.D. x 0.454 I.D.
1 Twenty-one rods are omitted: Twenty provide passage for control rods and one to certain in-core instrumentation.
I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:16.1Table:3.2.1-1 Page:2 of 3INITIAL CORE MECHANICAL DESIGN PARAMETERS 1(ALL DIMENSIONS ARE FOR COLD CONDITIONS.)Fuel RodsNumber39,372Outside Diameter, in.
0.422Diametral Gap, in.Regions 1, 2 & 30.0075Clad Thickness, in.0.0243Clad MaterialZircaloy-4Overall Length149.7Length of End Cap, overall, in.
0.688Length of End Cap, inserted in rod, in.0.250Fuel PelletsMaterialUO 2 sinteredDensity (% of Theoretical)Regions 1, 2 & 394/95/95Feed Enrichments w/oRegion 12.25Region 2 2.80Region 33.30Diameter, in.Regions 1, 2 & 30.3659Length, in.0.6000 I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:16.1Table:3.2.1-1 Page:3 of 3INITIAL CORE MECHANICAL DESIGN PARAMETERS 1(ALL DIMENSIONS ARE FOR COLD CONDITIONS.)Rod Cluster Control AssembliesNeutron Absorber5% Cd, 15% In. 80% AgCladding MaterialType 304 SS - Cold WorkedClad Thickness, in.0.019Number of ClustersFull Length53Part Length 0Number of Control Rods per Cluster20Length of Rod Control, in.158.45 (overall)150.57 (insertion length)Length of Absorber Section, in.142.00 (full length)Core StructureCore Barrel, in.
I.D.148.0O.D.152.5Thermal Shield, in.I.D.158.5 O.D.164.0Burnable Poison RodsNumber1434 MaterialBorosilicate GlassOutside Diameter, in.0.4395Inner Tube, O.D., in0.2365Clad MaterialS.S.Inner Tube Material S.S.Boron Loading, (natural), gm/cm of glass rod..0603