ML16336A388

From kanterella
Jump to navigation Jump to search
Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 2, Table 2.2-12, Control Room Atmospheric Dispersion Factors
ML16336A388
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16336A388 (3)


Text

I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T T Revision: 23Table: 2.2-12 Page: 1 of 3 CONTROL ROOM ATMOSPHERIC DISPERSION FACTORS Radioactivity Release Location Control Room Intake 0 - 2 hr /Q (sec/m 3) 2 - 8 hr /Q (sec/m 3) 8 - 24 hr /Q (sec/m 3) 1 - 4 day /Q (sec/m 3) 4 - 30 day /Q (sec/m 3) Unit 1 Unit Vent Unit 1 Emergency Intake 2.39E-03 1.54E-03 5.67E-04 4.30E-04 3.03E-04 Unit 2 Unit Vent Unit 2 Emergency Intake 2.50E-03 1.74E-03 6.33E-04 4.78E-04 3.65E-04 Unit 1 Unit Vent Unit 1 Normal Intake 2.23E-03 1.47E-03 5.39E-04 4.10E-04 2.90E-04 Unit 2 Unit Vent Unit 2 Normal Intake 2.33E-03 1.65E-03 5.95E-04 4.45E-04 3.40E-04 Unit 1 Containment Penetration Unit 1 Emergency Intake 1.06E-02 7.16E-03 2.46E-03 2.10E-03 1.55E-03 Unit 2 Containment Penetration Unit 2 Emergency Intake 1.21E-02 9.59E-03 3.12E-03 3.03E-03 2.76E-03 Unit 1 Containment Penetration Unit 1 Normal Intake 8.98E-03 6.10E-03 2.12E-03 1.82E-03 1.38E-03 Unit 2 Containment Penetration Unit 2 Normal Intake 1.01E-02 8.00E-03 2.60E-03 2.53E-03 2.30E-03 Unit 1 Containment Surface Unit 1 Emergency Intake 1.62E-03 1.09E-03 4.10E-04 3.44E-04 2.25E-04 Unit 2 Containment Surface Unit 2 Emergency Intake 1.54E-03 1.04E-03 4.11E-04 3.62E-04 3.13E-04 Unit 1 Containment Surface Unit 1 Normal Intake 1.53E-03 1.04E-03 3.93E-04 3.33E-04 2.22E-04 Unit 2 Containment Surface Unit 2 Normal Intake 1.46E-03 9.98E-04 3.87E-04 3.51E-04 3.02E-04 Unit 1 Refueling Water Storage Tank Vent Unit 1 Emergency Intake 1.20E-03 8.35E-04 4.45E-04 4.53E-04 2.98E-04 I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T T Revision: 23Table: 2.2-12 Page: 2 of 3 CONTROL ROOM ATMOSPHERIC DISPERSION FACTORS Radioactivity Release Location Control Room Intake 0 - 2 hr /Q (sec/m 3) 2 - 8 hr /Q (sec/m 3) 8 - 24 hr /Q (sec/m 3) 1 - 4 day /Q (sec/m 3) 4 - 30 day /Q (sec/m 3) Unit 2 Refueling Water Storage Tank Vent Unit 2 Emergency Intake 1.60E-03 1.30E-03 4.86E-04 4.06E-04 3.42E-04 Unit 1 Refueling Water Storage Tank Vent Unit 1 Normal Intake 1.13E-03 7.82E-04 4.02E-04 4.09E-04 2.78E-04 Unit 2 Refueling Water Storage Tank Vent Unit 2 Normal Intake 1.53E-03 1.25E-03 4.59E-04 3.91E-04 3.38E-04 Unit 1 SG PORVs/MSSVs Unit 1 Emergency Intake 9.26E-03 5.76E-03 2.80E-03 2.02E-03 1.93E-03 Unit 2 SG PORVs/MSSVs Unit 2 Emergency Intake 1.31E-02 1.01E-02 3.48E-03 3.25E-03 2.84E-03 Unit 1 SG PORVs/MSSVs Unit 1 Normal Intake 7.81E-03 4.48E-03 1.86E-03 1.35E-03 1.05E-03 Unit 2 SG PORVs/MSSVs Unit 2 Normal Intake 1.15E-02 9.00E-03 2.97E-03 2.91E-03 2.56E-03 Unit 1 West Main Steam Enclosure Unit 1 Emergency Intake 1.65E-02 1.10E-02 5.60E-03 5.35E-03 4.00E-03 Unit 2 West Main Steam Enclosure Unit 2 Emergency Intake 2.39E-02 1.89E-02 6.66E-03 6.00E-03 5.30E-03 Unit 1 West Main Steam Enclosure Unit 1 Normal Intake 1.23E-02 7.24E-03 3.26E-03 2.27E-03 2.02E-03 Unit 2 West Main Steam Enclosure Unit 2 Normal Intake 1.90E-02 1.54E-02 5.23E-03 4.88E-03 4.35E-03 Auxiliary Building Unit 1 or Unit 2 Emergency Intake 3.22E-02 2.59E-02 8.57E-03 7.96E-03 7.13E-03 I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T T Revision: 23Table: 2.2-12 Page: 3 of 3 CONTROL ROOM ATMOSPHERIC DISPERSION FACTORS Radioactivity Release Location Control Room Intake 0 - 2 hr /Q (sec/m 3) 2 - 8 hr /Q (sec/m 3) 8 - 24 hr /Q (sec/m 3) 1 - 4 day /Q (sec/m 3) 4 - 30 day /Q (sec/m 3) Auxiliary Building Unit 1 or Unit 2 Normal Intake 4.90E-02 3.85E-02 1.25E-02 1.17E-02 1.08E-02 Turbine Building Unit 1 or Unit 2 Emergency Intake 3.22E-02 2.59E-02 8.57E-03 7.96E-03 7.13E-03 Turbine Building Unit 1 or Unit 2 Normal Intake 4.90E-02 3.85E-02 1.25E-02 1.17E-02 1.08E-02