MONTHYEARML23271A1542023-09-28028 September 2023 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of License Amendment Request to Revise TS 5.5.17, Pre-Stressed Concrete Containment Tendon Surveillance Program ML23208A3072023-07-27027 July 2023 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of Relief Requests Regarding I6-RR-1, I6-RR-2, and I6-RR-3 (EPIDs L-2023-LLR-0030, L-2023-LLR-0031, L-2023-LLR-0032) ML23173A1522023-06-22022 June 2023 Request for Additional Information NextEra Fleet Emergency Plan Amendment Request ML23136A2782023-05-0505 May 2023 Email to R Coffey Point Beach SLRA Second Annual Update - Request for Additional Information Set 1 ML23122A0132023-05-0101 May 2023 NRR E-mail Capture - Point Beach 1 & 2 - Final RAI - License Amendment Request Regarding Risk-Informed Approach to Address GSI-191 ML23109A1862023-04-19019 April 2023 and Turkey Point Acceptance of Requested Licensing Action Proposed Alternative to Asme Section XI Authorizing Implementation of Asme Code Case N-752-1 ML23033A0292023-01-31031 January 2023 NRR E-mail Capture - Point Beach 1 & 2 - Final RAI (Volume 2) - License Amendment Request Regarding TSTS-505 ML22354A1612022-12-20020 December 2022 NRR E-mail Capture - Point Beach 1 & 2 - Final RAI - License Amendment Request Regarding TSTS-505 ML22291A3692022-10-18018 October 2022 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of License Amendment Request to Use Beacon Power Distribution Monitoring System ML22249A0052022-09-0202 September 2022 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of License Amendment and Exemptions Regarding Risk-Informed Approach to Address GSI-191 ML22229A1052022-08-17017 August 2022 Response to Questions Regarding Point Beach Nuclear Power Plant with Attachment ML22229A1022022-07-18018 July 2022 Original Request - Questions Regarding Point Beach Nuclear Power Plant ML22196A0062022-07-15015 July 2022 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of Requested Licensing Action TSTF-505, Revision 2, Provide Risk Informed Extended Completion Times - RITSTF Initiative 4b ML22094A0802022-04-0404 April 2022 NRR E-mail Capture - Point Beach Nuclear Plant, Units 1 and 2 - Acceptance of Requested Licensing Action License Amendment Request to Adopt TSTF-366 ML22006A2762022-01-0606 January 2022 SLR - FW: Subsequent License Renewal of Point Beach Nuclear Plant Unit Numbers 1 and 2, Manitowoc County, Wisconsin ML22006A1952022-01-0606 January 2022 SLR - FW: (External_Sender) 3 Additional Organizations Endorsing the Coalition (Now 50 Organizations, and 27 Individuals) Public Comments NRCs Dsgeis on NextEra Point Beach Nuclear Power Plant Subsequent License Renewal, D ML22006A2012022-01-0606 January 2022 SLR - FW: Comments of Michael J Keegan on Dseis Point Beach ML22004A1672022-01-0404 January 2022 SLR - Ref: Point Beach ML22004A3192022-01-0404 January 2022 SLR - FW: Point Beach ML22004A0012022-01-0404 January 2022 SLR - FW: Comments of Michael J Keegan on Dseis Point Beach ML22006A1942022-01-0404 January 2022 SLR - (External_Sender) 3 Additional Organizations Endorsing the Coalition (Now 50 Organizations, and 27 Individuals) Public Comments NRCs Dsgeis on NextEra Point Beach Nuclear Power Plant Subsequent License Renewal, Docke ML22004A3212022-01-0404 January 2022 SLR - FW: Comments of Michael J Keegan on Dseis Point Beach ML22004A3202022-01-0404 January 2022 SLR - FW: (External_Sender) 3 Additional Organizations Endorsing the Coalition (Now 50 Organizations, and 27 Individuals) Public Comments NRCs Dsgeis on NextEra Point Beach Nuclear Power Plant Subsequent License Renewal, D ML22004A1732022-01-0404 January 2022 SLR - FW: (External_Sender) 3 Additional Organizations Endorsing the Coalition (Now 50 Organizations, and 27 Individuals) Public Comments NRCs Dsgeis on NextEra Point Beach Nuclear Power Plant Subsequent License Renewal, D ML22004A3182022-01-0404 January 2022 SLR - FW: EPA Comment Letter - Point Beach SEIS ML22006A1992022-01-0303 January 2022 SLR - (External_Sender) Comments of Michael J Keegan on Dseis Point Beach ML22004A3172021-12-21021 December 2021 SLR - (External_Sender) EPA Comment Letter - Point Beach SEIS ML21362A6822021-12-17017 December 2021 SLRA Safety RAIs Set 14 Final Email ML21362A6712021-12-15015 December 2021 SLRA Safety RAIs Set 13 Final Email ML22006A2752021-12-0202 December 2021 SLR - (External_Sender) Subsequent License Renewal of Point Beach Nuclear Plant Unit Numbers 1 and 2, Manitowoc County, Wisconsin ML21341A6102021-11-16016 November 2021 SLRA Safety RAI Set 12 Final Email ML21314A4212021-11-10010 November 2021 Fws to NRC, Concurrence with ESA Determination for Point Beach Subsequent License Renewal ML21307A1522021-11-0909 November 2021 NRC to Fws, Request for Concurrence with Endangered Species Act Determinations for Point Beach Subsequent License Renewal ML21287A0852021-10-14014 October 2021 SLRA Safety RAI Set 11 Final Email ML21279A1202021-10-0505 October 2021 Email: Wi Shpo Review Point Beach Nuclear Plant SLR ML21286A6032021-10-0505 October 2021 SLRA Safety RAIs Set 10 Final Email ML21273A0232021-09-0202 September 2021 SLRA Safety RAI Set 9 Final Email ML21242A2282021-08-27027 August 2021 SLRA Draft Safety RAI Set 9 ML21242A2292021-08-27027 August 2021 SLRA Draft Safety RAI Set 9 Email ML21242A2462021-08-26026 August 2021 SLRA Safety RAIs Set 8 Final Email ML21242A2222021-08-23023 August 2021 SLRA Draft Safety RAI Set 8 ML21242A2232021-08-23023 August 2021 SLRA Draft Safety RAI Set 8 Email ML21242A2192021-08-20020 August 2021 SLRA Safety RAI Set 7 Final Email ML21242A2132021-08-13013 August 2021 SLRA Safety RAIs Set 7 Draft Email ML21242A2142021-08-13013 August 2021 SLRA Safety RAIs Set 7 Draft ML21242A2042021-08-12012 August 2021 SLRA Safety RAIs Set 5 Final Email ML21224A2042021-08-12012 August 2021 LTR-21-0225-1-RIII. Time Sensitive: Request for Further Inspection ML21242A0142021-08-12012 August 2021 SLRA Safety RAIs Set 6 Final Email ML21242A2382021-08-12012 August 2021 SLRA Safety RAIs Set 6 Final Email ML21242A0112021-08-0909 August 2021 SLRA Draft Safety RAIs Set 6 Email 2023-09-28
[Table view] |
Text
NRR-PMDAPEm Resource From: Chawla, Mahesh Sent: Tuesday, October 04, 2016 3:51 PM To: Manthei, Scott; Woyak, Bryan (Bryan.Woyak@nexteraenergy.com);
michael.millen@nexteraenergy.com; Locke, Kim (Kim.Locke@nexteraenergy.com);
Catron, Steve (Steve.Catron@fpl.com); Kilby, Gary Cc: Zimmerman, Jacob; Edmonds, Shavon; Mathew, Roy; Nold, David; Sweat, Tarico; Parillo, John; West, Khadijah; Wrona, David
Subject:
Request for Additional Information - Point Beach Nuclear Plant, Units 1 and 2 - LAR 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program - MF7352/53 By letter dated February 12, 2016 (Agencywide Document Access and Management System (ADAMS)
Accession No. ML16043A217), as supplemented by letter dated July 11, 2016 (ML16194A440), NextEra Energy Point Beach, LLC (NextEra), the licensee for Point Beach Nuclear Plant (PBNP), Units 1 and 2, requested to revise the PBNP facility operating licenses and the Technical Specifications (TS). The proposed revisions would remove license conditions that have been completed and are no longer in effect.
The NRC staff has reviewed this information and determined that the following additional information is needed to complete the review of the subject license amendment request.
REQUEST FOR ADDITIONAL INFORMATION In LAR Section 3.1 entitled Change to Operating Licenses, the licensee requests the following license conditions to be removed:
- 1) Amendment 240/Amendment 244, Emergency Diesel Generator Loading License condition states:
NextEra Energy Point Beach, LLC shall perform Train B Emergency Diesel Generator load testing over a range of 2877 to 2950 kW at rated power factor. This license condition will remain in effect until implementation of LAR 261 for Unit 2.
Amendment 238/Amendment 242, Modifications to Reduce Emergency Diesel Generator Loading License condition states:
NextEra Energy Point Beach, LLC shall implement modifications to reduce emergency diesel generator (EDG) loading such that the maximum loading will not exceed the 2000-hour rating of the EDGs.
Please confirm and provide a summary of the calculations and modifications performed to conclude that the EDG maximum loading is now within the 2000-hour rating of the EDGs. Also, confirm that EDG maximum loading considers loads added from the alternate source term (AST) modifications documented in letter dated April 14, 2011 (ADAMS Accession Number ML110240054), and the new auxiliary feedwater (AFW) pump motor modifications, and the AST control room (CR) modifications to automatically start the CR emergency fans.
- 2) Amendment 240 / Amendment 244, Mitigating Filtration Unit Motors License condition states:
NextEra Energy Point Beach, LLC shall procure mitigating filtration unit motors equivalent to W-14A/B (equivalent HP, efficiency, power factor, and voltage requirements).
1
Please provide a comparison of the mitigating filtration unit motors that are procured and installed at PBNP Units 1 and 2 with W-14A/B motors to conclude that the electrical power requirements for these motors are the same (HP, efficiency, power factor, and voltage requirements) and they did not increase loading on the EDGs.
Please arrange a teleconference with the NRC staff to discuss the requested information.
Thanks Mahesh Chawla Project Manager Phone: 301-415-8371 Fax: 301-415-1222 mahesh.chawla@nrc.gov 2
Hearing Identifier: NRR_PMDA Email Number: 3090 Mail Envelope Properties (Mahesh.Chawla@nrc.gov20161004155100)
Subject:
Request for Additional Information - Point Beach Nuclear Plant, Units 1 and 2 -
LAR 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program - MF7352/53 Sent Date: 10/4/2016 3:51:17 PM Received Date: 10/4/2016 3:51:00 PM From: Chawla, Mahesh Created By: Mahesh.Chawla@nrc.gov Recipients:
"Zimmerman, Jacob" <Jacob.Zimmerman@nrc.gov>
Tracking Status: None "Edmonds, Shavon" <Shavon.Edmonds@nrc.gov>
Tracking Status: None "Mathew, Roy" <Roy.Mathew@nrc.gov>
Tracking Status: None "Nold, David" <David.Nold@nrc.gov>
Tracking Status: None "Sweat, Tarico" <Tarico.Sweat@nrc.gov>
Tracking Status: None "Parillo, John" <John.Parillo@nrc.gov>
Tracking Status: None "West, Khadijah" <Khadijah.West@nrc.gov>
Tracking Status: None "Wrona, David" <David.Wrona@nrc.gov>
Tracking Status: None "Manthei, Scott" <Scott.Manthei@nexteraenergy.com>
Tracking Status: None "Woyak, Bryan (Bryan.Woyak@nexteraenergy.com)" <Bryan.Woyak@nexteraenergy.com>
Tracking Status: None "michael.millen@nexteraenergy.com" <michael.millen@nexteraenergy.com>
Tracking Status: None "Locke, Kim (Kim.Locke@nexteraenergy.com)" <Kim.Locke@nexteraenergy.com>
Tracking Status: None "Catron, Steve (Steve.Catron@fpl.com)" <Steve.Catron@fpl.com>
Tracking Status: None "Kilby, Gary" <Gary.Kilby@fpl.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 2826 10/4/2016 3:51:00 PM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal
Expiration Date:
Recipients Received: