ES-301 Admi nistrative Topics Outl ine Form ES-301-1 Date of Examination: 4118/16 Operating Test Number: ILT 14-1 Facility: Ouad Cities Examination Level: RO X SnO n Administrative Topic (See Note)
Type Code*
Describe activity to be performed Conduct of Operations S,N Enter Substitute Value for RWCU Pump Flow KlA:2.1.19 Rating: 3.9 Ability to use plant computers to evaluate system or component status.
Conduct of Operations S,D Verification of SBGTS Lineup K/A:2.1.31 Rating: 4.6 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup.
Equipment Control S,D,P Print Reading Exercise KIA: 2.2.41 Rating: 3.5 Ability to obtain and interpret station electrical and mechanical drawings.
Radiation Control S,N ARM Trip Unit Set Point Check KA: 2.3.5 Rating: 2.9 Ability to use radiation monitoring systems, such as fixed radiation monitors and alarms, portable instruments, personnel monitorinq equipment, etc.
Emergency Procedures/Plan N/A N/A NOTE: All ítems (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (< 3 for ROs; < 4 for SROs & RO retakes)
(N)ew or (M)odified f rom bank (> 1)
(P)revious 2 exams (< 1; randomly selected)
- Type Codes & Critería:
- 301, e
ES-301 Administrative Topics Outl ine Form ES-301-1 Facility: Quad Cities Examination Level: RO n SRO X Date of Examination :411 8116 Operating Test Number: tLT 14-1 Administrative Topic (See Note)
Type Code*
Describe activity to be performed Conduct of Operations S,D Shift Staffing (SRO 26-l)
K/A: 2.1.5 Rating: 3.9 Ability to use procedures related to shift staffing, such as minimum crew complement, overtime limitations, etc.
Conduct of Operations S,D Pre Refueling Activities KA: 2.1.36 Rating: 4.1 Knowledge of procedures and limitations involved in core alterations.
Equipment Control S,M Fire lmpairment l(A: 2.2.14 Rating: 4.3 Knowledge of the process for controlling equipment configuration or status.
Radiation Control S,P Compensatory Measures for lnoperable Service Water Rad Monitor KA: 2.3.15 Rating: 3.1 Knowledge of radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitorinq equipment, etc.
Emergency Procedures/Plan S
N Determine Protective Action Recommendations (PARS)
K/A: 2.4.44 Rating: 4.4 Knowledge of emergency plan protective action recommendations.
NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (< 3 for ROs; < 4 for SROs & RO retakes)
(N)ew or (M)odified f rom bank (¿ 1)
(P)revious 2 exams (< 1; randomly selected)
ES 301, Page 22 o 27
ES-301 Control Room/ln-Plant Svstems Outline Form ES'301'2 Facility: Quad Cities Exam Level: RO X SRo-I T SRo-U T Date of Examination: 4118116 Operating Test No.: 14-1 Control Room Systems:'8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code.
Safety Function a.RMCS, SG 2.1.44 3.913.8 Perform One-Rod-Out I nterlock Surveillance S,D,L,P 1
- b. Reactor Condensate System, 256000 42.06 3.213.2 lnjecting Standby Coolant S, EN, N, A 2
- c. Main and Reheat Steam System, 239001 A4.02 3.213.2 Control Reactor Pressure using the Main Steam Line Drains S,N 3
- d. Reactor Core lsolation Cooling System, 217000 44.03 3.413.3 RCIC Manual lnitiation (Hard Card)with an lnadvertent lsolation S,D,A 4
- e. High Drywell Pressure, 295024 E41.14 3.4/3.5 Vent Containment lrrespective of Release Rates with APCV (Failure of Torus Valve to Open, Requiring Venting Through the Drywell)
S, D, EN, P, A
5 f, lnstrumentation, 216000 K1.01 3.9/4.1 lnstallOPRM Jumpers on RPS B S,N 7
- g. Component Cooling Water System,400000 44.01 3.1/3.0 Reverse RHRSW Heat Exchanger Flow S,N I
- h. A.C. Electrical Distribution, 262001 A4.01 3.4/3.7 Energize 480 VAC Bus 15 with a Failure of the Normal Feed S,D,A 6
ln-Plant Systems'(3 for RO); (3 for SRO-l); (3 or 2 for SRO-U)
- i. Partial or Complete Loss of D.C. Power,295004 4A1.01 3.313.4 Flex 125/250 VDC Operation N,E,R 6
- j. Control Room HVAC,290003 SG 2.1.20 4.614.6 Start the Control Room B Train HVAC with a Failure of the FCV N,A,R I
- k. Fire Protection System, 286000 SG 2.1 3A 4.4/4.0 Locally Start Up the Tz A Fire Diesel D
I All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U A)lternate path (C)ontrolroom (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)cA (S)imulator 4-61 4-612-3
<91<8134
>11¿11>1
>1 l>1/ 1 (control room system)
>1 />1 l>1
>21>21>1
< 3 / < 3/ < 2 (randomly selected)
>1t>1/>1
ES-301 Control Room/ln-Plant Svstems Outline Form ES-301'2 Facility: Quad Cities Exam Level: Ro I sRo-l x sno-u I Date of Examination: 4118116 Operating Test No.: 14-1 Control Room Systems:.8 for RO; 7 for SRO-I; 2 or Slor SRO-U System / JPM Title Type Code" Safety Function
- b. Reactor Condensate System, 256000 42.06 3.213.2 lnjecting Standby Coolant S, EN, N, A 2
- c. Main and Reheat Steam System,239001 A4.02 3.213.2 Control Reactor Pressure using the Main Steam Line Drains S,N 3
- d. Reactor Core lsolation Cooling System, 217000 44.03 3.4/3.3 RCIC Manual lnitiation (Hard Card) with an lnadvertent lsolation S,D,A 4
- e. High Drywell Pressure, 295024 E41.14 3.4/3.5 Vent Containment lrrespective of Release Rates with APCV (Failure of Torus Valve to Open, Requiring Venting Through the Drywell)
S, D, EN, P, A 5
- f. lnstrumentation, 216000 K1.01 3.9/4.1 lnstallOPRM Jumpers on RPS B S,N 7
g
- h. A.C. Electrical Distribution, 262001 A4.01 3.413.7 Energize 480 VAC Bus 15 with a Failure of the Normal Feed S,D,A 6
ln-Plant Systems'(3 for RO); (3 for SRO-I); (3 or 2 for SRO'U)
- i. Partial or Complete Loss of D.C. Power, 295004 A41.01 3.313.4 Flex 125/250 VDC Operation N,E,R 6
- j. Control Room HVAC, 290003 SG 2.1.20 4.614.6 Start the Control Room B Train HVAC with a Failure of the FCV N,A,R I
- k. Fire Protection System, 286000 SG 2.1.30 4.4/4.0 Locally Start Up lhe Vz A Fire Diesel D
I All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U A)lternate palh (C)ontrolroom (D)irect from bank (E)mergency or abnormal in-plant (EN) gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)cA (S)imulator 4-6 /4-6 /2-3
<91<81s4
>11>11>1
>1 l>1/ > 1 (control room system)
>1t>11>1
>2t>21>1 s 3 / < 3 / < 2 (randomly selected)
>'t l>11¿1