ML16154A692

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-269/94-28,50-270/94-28 & 50-287/94-28 on 940828-0924 & Notice of Violation.Violation of Concern Because Failure to Follow Procedure During Mod Endangered Plant Personnel & Resulted in Loss of Radiation Monitors
ML16154A692
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 10/20/1994
From: Sinkule M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Hampton J
DUKE POWER CO.
Shared Package
ML16154A693 List:
References
NUDOCS 9411070179
Download: ML16154A692 (4)


See also: IR 05000269/1994028

Text

PRICORITY 2

REGULATOR

WMTNUTION SYSTEM (RIDS)

ACCESSION NBR:9411070179

DOC.DATE: 94/10/20 NOTARIZED: NO

DOCKET #

ACIL:50-269 Oconee Nuclear Station, Unit 1, Duke Power Co.

05000269

is

50-270 Oconee Nuclear Station, Unit 2, Duke Power Co.

05000270

50-287 Oconee Nuclear Station, Unit 3, Duke Power Co.

05000287

AUTH.NAME

AUTHOR AFFILIATION

SINKULE,M.V.

Region 2 (Post 820201)

RECIP.NAME

RECIPIENT AFFILIATION

P

HAMPTON,J.W.

Duke Power Co.

SUBJECT: Forwards insp repts 50-269/94-28,50-270/94-28 & 50-287/94-28

R

on 940828-0924 & notice of violation.Violation of concern

because failure to follow procedure during mod endangered

I

plant personnel & resulted in loss of radiation monitors.

DISTRIBUTION CODE: IE01D

COPIES RECEIVED:LTR

ENCL

SIZE: 3416 0

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response

R

NOTES:

RECIPIENT

COPIES

RECIPIENT

COPIES

ID CODE/NAME

LTTR ENCL

ID CODE/NAME

LTTR ENCL

PD2-3 PD

1

1

WIENS,L

1

1

T

INTERNAL:

ACRS

2

2

AEOD/DEIB

1

1

Y

AEOD/SPD/RAB

1

1

AEOD/SPD/RRAB

1

1

AEQD TTC

1

1

DEDRO

1

1

IEE CE

02

1

1

NRR/DORS/OEAB

1

1

NRR/DRCH/HHFB

1

1

NRR/PMAS/IRCB-E

1

1

2

NUDOCS-ABSTRACT

1

1

OE DIR

1

1

OGC/HDS2

1

1

RGN2

FILE

01

1

1

D

EXTERNAL: LITCO BRYCE,J H

1

1

NOAC

1

1

NRC PDR

1

1

0

C

U

M

E

N

T

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL

DESK, ROOM PI-37 (EXT 504-2083 ) TO ELIMINATE YOUR NAME FROM

DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR

20

ENCL

20

October 20, 1994

Duke Power Company

ATTN: Mr. J. W. Hampton

Vice President, Oconee Site

P. 0. Box 1439

Seneca, SC 29679

SUBJECT: NOTICE OF VIOLATION

(NRC INSPECTION REPORT NOS. 50-269/94-28, 50-270/94-28 AND

50-287/94-28)

Gentlemen:

This refers to the inspection conducted by P. E. Harmon of this office on

August 28 - September 24, 1994. The inspection included a review of

activities authorized for your Oconee facility. At the conclusion of the

inspection, the findings were discussed with those members of your staff

identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

Based on the results of this inspection, certain activities appeared to be in

violation of NRC requirements, as specified in the enclosed Notice of

Violation (Notice). The first violation is of concern because the failure to

follow procedure during a modification activity endangered plant personnel and

resulted in the loss of the majority of the Unit 1 radiation monitors. The

second violation is of concern because an important limit for steam generator

integrity was not incorporated into procedures, which resulted in this limit

being exceeded for the 3B Steam Generator. The third violation is of concern

because the dry out of the 3B steam generator could have been prevented had

adequate and timely corrective action been pursued for turbine bypass valves

randomly repositioning following restoration of power.

You are required to respond to this letter and should follow the instructions

specified in the enclosed Notice when preparing your response. In your

response, you should document the specific actions and any additional actions

you plan to prevent recurrence. After reviewing your response to this Notice,

including your proposed corrective actions and the results of future

inspections, the NRC will determine whether further NRC enforcement action is

necessary to ensure compliance with the NRC regulatory requirements.

In accordance with 10 CFR 2.970 of the NRC's "Rules of Practice", a copy of

this letter and its enclosures will be placed in the NRC Public Document Room.

The responses directed by this letter and the enclosed Notice are not subject

to the clearance procedures of the Office of Management and Budget as required

by the Paperwork Reduction Act of 1980, Pub. L.

No.96-511.

9411070179 941020

OFFICIAL COPY

PDR

ADOCK 05000269

PDR

DPC

2

Should you have any questions concerning this letter, please contact us.

Sincerely,

Original signed by

Marvin V. Sinkule, Chief

Reactor Projects Branch 3

Division of Reactor Projects

Docket Nos. 50-269, 50-270, 50-287 and 72-4

License Nos. DPR-38, DPR-47, DPR-55 and SNM-2503

Enclosures:

1. Notice of Violation

2. NRC inspection Report

cc w/encls:

Mr. J. E. Burchfield

Compliance

.Duke

Power Company

P. 0. Box 1439

Seneca, SC 29679

Mr. A. V. Carr, Esq.

Duke Power Company

422 South Church Street

Charlotte, NC 28242-0001

Mr. Robert P. Gruber

Executive Director

Public Staff - NCUC

P. 0. Box 29520

Raleigh, NC 27626-0520

Mr. Robert B. Borsum

Babcock and Wilcox Company

Nuclear Power Generation Division

1700 Rockville Pike, Suite 525

Rockville, MD 20852

Mr. J. Michael McGarry, III, Esq.

Winston and Strawn

1400 L Street, NW

Washington, D. C. 20005

cc w/encls cont'd:

(See page 3)

DPC

3

cc w/encls cont'd:

Office of Intergovernmental Relations

116 West Jones Street

Raleigh, NC 27603

Mr. Max Batavia, Chief

Bureau of Radiological Health

South Carolina Department of Health

and Environmental Control

2600 Bull Street

Columbia, SC 29201

Manager, LIS

NUS Corporation

2650 McCormick Drive

Clearwater, FL 34619-1035

Mr. G. A. Copp

Licensing - ECO50

Duke Power Company

P. 0. Box 1006

Charlotte, NC 28201-1006

OMs.

Karen E.

Long

Assistant Attorney General

N. C. Department of Justice

P. 0. Box 629

Raleigh, NC 27602

Distribution w/encls:

L. A. Wiens, NRR

R. Carroll, RII

M. V. Sinkule, RH

G. A. Hallstrom, RH

PUBLIC

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

Route 2, Box 610

Seneca, SC 29672

SEND

OFC

RII:DRP

TO

NAME

RCarroll

PDR?

DATE

10/

-/94

/

/94

/

/94

/

/94

/

/

94

Yes

No COPY?

es

No

Yes

No

Yes

No

Yes

No

Yes

No

OFFICIAL

CORD COPY

DOCUMENT NAME:

G:\\0NS94-28.RPT