Letter Sequence Other |
|---|
|
Results
Other: ML092120136, ML103340090, ML110480046, ML111020032, ML120180027, ML120180030, ML13162A662, ML14084A515, ML14148A240, ML15307A055, ML15313A308, ML15313A309, ML16074A153, ML16120A471, ML16153A207
|
MONTHYEARML0921201362009-01-0505 January 2009 United States Geological Survey - Redacted Revised Safety Analysis Report, Technical Specifications, and Environmental Report to Support License Renewal (ME1593) Project stage: Other ML1013302092010-05-19019 May 2010 United States Geological Survey - Request for Additional Information Regarding Financial Qualifications for License Renewal, Triga Reactor Project stage: RAI ML1020907012010-07-15015 July 2010 USGS Request for a 60-Day Extension to Respond to the Financial RAIs Project stage: Request ML1024400032010-09-0909 September 2010 United States Geological Survey - Request for an Additional 60 Days to Complete the Response to the NRC Request for Additional Information on the License Renewal Review (Tac ME1593) Project stage: RAI ML1025100772010-09-29029 September 2010 U.S. Geological Survey - Request for Additional Information on the License Renewal Review Project stage: RAI ML1033400902010-11-24024 November 2010 Us Geological Survey Triga Reactor Response to the RAI Concerning R-113 License Renewal Project stage: Other ML11027A0012011-02-0101 February 2011 United States Geological Survey - NRC Response to USGS Letter Request for Extension of NRC Request for Additional Information on the USGS License Renewal Application Project stage: RAI ML1104800462011-02-11011 February 2011 Response to Letter of February 1, 2011 Concerning R-113 License Renewal Project stage: Other ML1110200322011-04-13013 April 2011 U.S. Geological Survey - Response to USGS Letter - Request for an 18-Month Extension to Provide Additional Information for the License Renewal (Tac No. ME1593) Project stage: Other ML1134600142011-11-30030 November 2011 United States Geological Survey - *Redacted* Licensee Response to NRC Request for Additional Information Questions 7 and 8 License Renewal Project stage: Response to RAI ML1202400032012-01-0303 January 2012 United States Geological Survey - *Redacted* Licensee Response to NRC Request for Additional Information Question 15.3 (ME1593) Project stage: Response to RAI ML1201800272012-01-17017 January 2012 United States Geological Survey, E-mail from T. Debey, USGS to G. Wertz, NRC Project Manager December Progress Report Supporting the Relicensing Project stage: Other ML1201800302012-01-17017 January 2012 Unites States Geological Survey, December 2011 Progress Report Supporting the Relicensing Prepared by Colorado School of Mines Project stage: Other ML12075A0012012-03-21021 March 2012 United States Geological Survey - NRC Request for Additional Information Ar-41 Dose Calculations Relating to the License Renewal (Tac No. ME1593) Project stage: RAI ML12270A4152012-10-0202 October 2012 United States Geological Survey - Additional Clarification Requested Responses to NRC Request for Additional Information Dated September 29, 2010 (Tac No. ME1593) Project stage: RAI ML12334A0012012-11-16016 November 2012 United States Geological Survey - *Redacted* Response to NRC Request for Additional Information Dated October 2, 2012 (Tac No. ME1593) Project stage: Response to RAI ML13052A1922012-12-20020 December 2012 United States Geological Survey - Teleconference Between G. Wertz, NRC Project Manager and T. Debey, Reactor Supervisor NRC Request for Additional Information Dated October 2, 2012 and Licensee Responses Dated November 16, 2012 Project stage: RAI ML13052A1792013-02-0808 February 2013 United States Geological Survey - *Redacted* - Response to NRC Request for Additional Information Dated October 2, 2012 and Telephone Conference Dated December 20, 2012 Project stage: Response to RAI ML13059A0272013-03-0707 March 2013 United States Geological Survey - Additional Clarification Requested Responses to NRC Request for Additional Information Dated September 29, 2010 Project stage: RAI ML13162A6622013-05-17017 May 2013 Redacted USGS RAI Clarification Information Needed to Support the USGS License Renewal SAR Project stage: Other ML13190A0522013-07-15015 July 2013 United States Geological Survey - Additional Clarification Requested Responses to the U.S. Nuclear Regulatory Commission Request for Additional Information Dated September 29, 2010 Project stage: RAI ML14014A1232014-01-22022 January 2014 U.S. Geological Survey - Request for Additional Information Review of the Operator Requalification Program for the License Renewal for the Geological Triga Reactor Project stage: RAI ML14023A7952014-01-28028 January 2014 U.S. Geological Survey - Request for Additional Information Review of the Emergency Plan for the License Renewal for the Geological Survey Triga Reactor Project stage: RAI ML14070A0402014-02-19019 February 2014 U.S. Geological Survey Triga Reactor (Gstr), Responses to Reactor Operator Requalification Questions Project stage: Request ML14084A5152014-03-27027 March 2014 U.S. Geological Survey - Approval of the U.S. Geological Survey Operator Requalification Program Project stage: Other ML14148A2402014-05-15015 May 2014 USGS Emergency Plan: Response to Emergency Plan Question for License Renewal Review-Redacted Version Project stage: Other ML16090A1642014-05-30030 May 2014 USGS (Redacted) Emergency Plan, Revision 14, May 31, 2014 Project stage: Request ML14183A4252014-07-0909 July 2014 U.S. Geological Survey Review of the Emergency Plan for License Renewal Project stage: Approval ML14211A5862014-08-25025 August 2014 U.S. Geological Survey - Request for Additional Information and Clarification to Previous Responses to the U.S. Nuclear Regulatory Commission Request for Additional Information Project stage: RAI ML15252A0092015-09-10010 September 2015 Us Geological Survey Request for Additional Information Regarding the Therma-Hydraulic Analysis of the USGS Triga Research Reactor to Support the License Renewal Review Project stage: RAI ML15313A3082016-01-12012 January 2016 Letter: U.S. Geological Survey - Determination of Acceptability and Sufficiency for Docketing and Opportunity for Hearing Regarding the Application from the U.S. Geological Survey Project stage: Other ML16042A5752016-01-22022 January 2016 U.S. Geological Survey - Responses to RAI Questions La, Lb, and Lc Project stage: Request ML15313A3092016-02-0101 February 2016 Federal Register Notice on License Renewal Application; Opportunity to Request a Hearing and to Petition for Leave to Intervene; Order on U.S. Geological Survey Triga Research Reactor Project stage: Other ML16027A1342016-02-0808 February 2016 Us Geological Survey - Request for Additional Information Regarding the Review of the License Renewal of the Us Geological Survey Triga Research Reactor Draft 1.27.16 Project stage: Draft RAI ML16110A0082016-04-0101 April 2016 U.S. Dept. of the Interior, Geological Survey, Response to NRC Staff Request for Additional Information for License Renewal Review April 1, 2016 Project stage: Request ML16112A0032016-04-25025 April 2016 U.S. Geological Survey - Request for Additional Information for the Review of the Physical Security Plan Regarding the License Renewal of the U.S. Geological Survey Triga Research Reactor Project stage: RAI ML16120A4712016-04-29029 April 2016 USGS Training, Research, Isotope Production, General Atomics Research Reactor License Renewal Ipac Trust Resources Report Project stage: Other ML16153A2072016-05-27027 May 2016 E-mail U.S. Geological Survey Triga Research Reactor Environmental Assessment Review Project stage: Other ML15307A0552016-06-0101 June 2016 U.S. Geological Survey Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-113 for the U.S. Geological Survey Training, Research, Isotope Production, General Atomics Research R Project stage: Other ML15307A0252016-06-0606 June 2016 FRN - USGS EA Draft Rev 4 Gaw 11.2.15 Project stage: Draft Other ML16147A6422016-06-28028 June 2016 U.S. Geological Survey - Request for Additional Information Regarding the Review of the License Renewal of the U.S. Geological Survey Triga Research Reactor Project stage: RAI ML16277A2162016-09-12012 September 2016 USGS Response to Request for Additional Information Dated 06/28/2016 Project stage: Response to RAI ML16273A3042016-09-22022 September 2016 Us Department of the Interior, Geological Survey, Responses to E-Mail Questions Project stage: Request ML16074A1512016-10-17017 October 2016 U.S. Geological Survey (USGS) - Issuance of Renewed Facility Operating License No. R-113 for the USGS Triga Research Reactor Project stage: Approval ML16074A1542016-10-17017 October 2016 FRN - USGS FRN Issuance of Renewal License Project stage: Approval ML16074A1532016-10-17017 October 2016 TS - U.S. Geological Survey - Technical Specifications, Appendix a, for the USGS Renewed Facility Operating License, R-113 Project stage: Other 2014-01-28
[Table View] |
Text
From:
Opila - CDPHE, Jennifer To:
Wertz, Geoffrey
Subject:
[External_Sender] Re: U.S. Geological Survey Research Reactor RE: State of Colorado Review of the draft Environmental Assessment Supporting License Renewal Date:
Friday, May 27, 2016 11:13:20 AM Mr. Wertz, The contact information you have for me is correct. Thank you for the opportunity to review this document. I have no comments and agree with the NRC's determination that there are no significant environmental impacts from the proposed action, and the proposed action will not have a significant effect on the quality of the human environment.
Jennifer T. Opila, MPA Radiation Program Manager P 303-692-3403 l F 303-691-7841 l C 720-666-4074 4300 Cherry Creek Drive South,Denver, CO 80246-1530 jennifer.opila@state.co.usl www.colorado.gov/cdphe/radiation On Wed, May 25, 2016 at 2:08 PM, Wertz, Geoffrey <Geoffrey.Wertz@nrc.gov> wrote:
Hello Ms. Jennifer Opila, This email is a follow-up to the voice message I left earlier today:
The U.S. Nuclear Regulatory Commission (NRC) is nearing the completion of our review of the license renewal application (LRA) for the U.S. Geological Survey TRIGA Research Reactor (GSTR) located on the property of the U.S. Denver Federal Center in Lakewood, Colorado. The NRC review of the GSTR LRA includes the issuance of an Environmental Assessment (EA), which involves a radiological review of the proposed continued operation of the GSTR facility for an additional 20 years from issuance of the renewed license (which is anticipated later this year).
One of the final steps in the EA development process is an opportunity for a review of the draft EA by the facilitys state. Please review the attached draft EA and contact me with any comments, questions or concerns. We will attempt to resolve any issues to your satisfaction in order obtain your acknowledgement that our EA is acceptable. We request an email response within 30-days in order to maintain our review schedule. Please note that your email response will be referenced in the final EA and a copy of the email will be publicly-available in our document management system in accordance with the NRC policy for openness.
Since the EA is pre-decisional (i.e., in draft form), we request that you do not release it to public. A public version of the final EA will be noticed in the Federal Register prior to the issuance of the renewed license.
Finally, for our records, please confirm the accuracy of the information below:
Jennifer Opila, Program Manager Hazardous Materials & Waste Management Division Department of Public Health and Environment HMWM-RAD-B2 4300 Cherry Creek Drive South Denver, CO 80246-1530 PH (303)692-3403 FX (303)759-5355 Jennifer.opila@state.co.us Thanks in advance for your support.
Geoffrey A. Wertz, P.E.
Project Manager Research and Test Reactors U.S. Nuclear Regulatory Commission (301) 415-0893 geoffrey.wertz@nrc.gov