CONVERSATION RECORD NRC FORM 699 (05-2012)

U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 699 (05-2012)

DATE TIME TYPE OF CONVERSATION NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU TELEPHONE NO.

ORGANIZATION IN-PERSON E-MAIL TELEPHONE INCOMING OUTGOING SUBJECT

SUMMARY

ACTION REQUIRED NAME OF PERSON DOCUMENTING CONVERSATION SIGNATURE DATE ACTION TAKEN TITLE OF PERSON TAKING ACTION SIGNATURE OF PERSON TAKING ACTION DATE Page 1 Continue on Page 2 E-MAIL ADDRESS PM AM 12/20/2012 (303) 236-4726 USGS TRIGA Reactor Discussion of RAI Responses from USGS letter dated Nov. 16, 2012 The teleconference included NRC staff Al Adams, Patrick Boyle, and Linh Tran, and ERI staff Morgan Libby. Mr. Tim Debey had several of the Colorado School of Mines staff and students attend. The discussion was to obtain clarifications on the RAI responses submitted by USGS letter dated Nov. 16, 2012, in response to NRC RAI letter dated October 2, 2012.

Specific points included (RAI numbers referenced from the NRC October 2, 2012 letter):

1. RAI 9 - please identify the 8 vs 12 wt. percent fuel for both OC and LCC. Please provide dimensions of the fuel, control rods and components. Please provide the delayed neutron fraction, all rods out keff, and control rod worths. Please provide a power distribution profile for the OC and LCC.
2. RAI 10 - please provide the fuel temperature coefficient for the OC and LCC.
3. RAI 12 - please provide the dimensions of the unit cell, pressure drops, and a diagram of the RELAP model. Please provide the RELAP model assumptions. Please provide the response to a pulse and uncontrolled rod withdraw.
4. RAI 15.3 - please explain the use of 22 kw/fuel element and provide the results.
5. RAI 24.9 - please explain how the use of COMPLY, and the results.
6. RAI 26 d & e - please explain entire response.

As discussed above, clarifications to the RAI Responses will be provided by the end of January, 2013.

RAI Response Clarifications provided by letter dated Feb. 8, 2013 (ML13045A481) Redacted version submitted to ADAMS Feb.

19, 2013 Geoffrey Wertz NRC Project Manager



Mr. Tim Debey, Reactor Supervisor tdebey@usgs.gov



00 9

CONVERSATION RECORD (Continued)

SUMMARY