ZOC"Sp14REG&<
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 DUKE POWER COMPANY DOCKET NO. 50-269 OCONEE NUCLEAR STATION, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.
221 License No. DPR-38
- 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A. The application for amendment to the Oconee Nuclear Station, Unit I (the facility) Facility Operating License No. DPR-38 filed by the Duke Power Company (the licensee) dated February 20, 1996, as supplemented by letter dated October 16, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations as set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
9702250276 970219 PDR ADOCK 05000269 P
-2
- 2.
Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 3.B of Facility Operating License No. DPR-38 is hereby amended to read as follows:
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 221, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
- 3.
This license amendment is effective as of its date of issuance and shall be implemented within 30 days from the date of issuance.
Implementation shall include concurrent revision of the Selected Licensee Commitment Manual in accordance with the application for this amendment.
FOR THE NUCLEAR REGULATORY COMMISSION Herbert N. Berkow, Direct Project Directorate 11-2 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation
Attachment:
Technical Specification Changes Date of Issuance:
February 19, 1997
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 DUKE POWER COMPANY DOCKET NO. 50-270.
OCONEE NUCLEAR STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 221 License No. DPR-47
- 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A. The application for amendment to the Oconee Nuclear Station, Unit 2 (the facility) Facility Operating License No. DPR-47 filed by the Duke Power Company (the licensee) dated February 20, 1996, as supplemented by letter dated October 16, 1996, complies with the standards and requirements of the Atomic Energy Act of.1954, as amended (the Act), and the Commission's rules and regulations as set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
-2
- 2.
Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 3.B of Facility Operating License No. DPR-47 is hereby amended to read as follows:
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 221, are-hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
- 3.
This license amendment is effective as of its date of issuance and shall be implemented within 30 days from the date of issuance. Implementation shall include concurrent revision of the Selected Licensee Commitment Manual in accordance with the application for this amendment.
FOR THE NUCLEAR REGULATORY COMMISSION SHerertN. Berk Directo Project Directorate 11-2 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation
Attachment:
Technical Specification Changes Date of Issuance:
February 19, 1997
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2055-)001 DUKE POWER COMPANY DOCKET NO. 50-287 OCONEE NUCLEAR STATION. UNIT 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.
218 License No. DPR-55
- 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A. The application for amendment to the Oconee Nuclear Station, Unit 3 (the facility) Facility Operating License No. DPR-55 filed by the Duke Power Company (the licensee) dated February 20, 1996, as supplemented by letter dated October 16, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations as set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
-2
- 2.
Accordingly, the license is hereby amended by.page changes to the.
Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 3.B of Facility Operating License No. DPR-55 is hereby amended to read as follows:
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.218, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
- 3.
This license amendment is effective as of its date of issuance and shall be implemented within 30 days from the date of issuance.
Implementation shall include concurrent revision of the Selected Licensee Commitment Manual in accordance with the application for this amendment.
FOR THE NUCLEAR REGULATORY COMMISSION Herbert N. Berkow, Dire Project Directorate II-2 Division of Reactor.Projects -
I/II Office of Nuclear Reactor Regulation
Attachment:
Technical Specification Changes Date of Issuance:
February 19, 1997
ATTACHMENT TO LICENSE AMENDMENT NO.221 FACILITY OPERATING LICENSE NO. DPR-38 DOCKET NO. 50-269 AND TO LICENSE AMENDMENT NO. 221 FACILITY OPERATING LICENSE NO. DPR-47 DOCKET NO. 50-270 AND TO LICENSE AMENDMENT NO. 218 FACILITY OPERATING LICENSE NO. DPR-55 DOCKET NO. 50-287 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the areas of change.
Remove Pages Insert Pages 4.1-10 4.1-10 4.1-12 4.1-12 3.1-12 3.1-12 3.1-13 3.1-13 3.1-21 3.1-21 3.1-22 3.1-22
Table 4.1-3 Minimum Sampling Frequency And Analysis Proaram Item Check Frequency
- 1.
- a. Gamma Isotopic Analysis
- a. 3 times/week*
- b. Boron Concentration
- b. 2 times/week**
- c. rDetermination (2)
- c. Semi-annually
- 2.
Borated Water Storage Boron Concentration Weekly* and after each Tank Water Sample makeup
- 3.
Core Flooding Tank Boron Concentration Monthly* and after each makeup
- 4.
Spent Fuel Pool Water Boron Concentration Monthly and after each Sample makeup
- 5.
OTSG or Final Feedwater Gamma Isotopic Analysis Weekly*
- 6.
Concentrated Boric Acid Boron Concentration Weekly*
I Tank Not applicable if reactor is in a cold shutdown condition for a period exceeding the sampling frequency.
Applicable only when fuel is in the reactor.
Amendment No. 221 (Unit 1)
OCONEE - UNITS 1, 2, & 3 4.1-10 AedetN.21(nt2 Amendment No. 221 (Unit 2)
Amendment No..218 (Unit 3)
TABLE 4.1-3 NOTES (1) (Not Used)
(2) E determination will be started when gross gamma activity analysis indicates greater than 10pCi/ml and will be determined for each 10gCi/ml increase in gross gamma activity analysis thereafter. A radiochemical analysis for this purpose shall consist of a quantitative measurement of 95 percent of the radionuclides in the reactor coolant with half lives greater than 30 minutes..
(3) (Not Used)
(4) (Not Used)
(5) (Not Used)
(6) (Not Used)
(7) (Not Used)
(8) (Not Used)
(9) (Not Used)
(10) (Not Used)
(11) (Not Used)
OCONEE -UNITS 1,
2, 3
4.1-12 Amendment No. 221 (Unit 1)
Amendment No. 221 (Unit 2)
Amendment No. 218 (Unit 3)
0 g
INTENTIONALLY BLANK Amendment No. 221 (Unit 1)
OCONEE -
UNITS 1, 2, & 3 3.1-12 Amendment No. 221 (Unit 2)
Amendment No. 218 (Unit 3)
INTENTIONALLY BLANK Amendment No. 221 (Unit 1)
OCONEE -
UNITS 1, 2, & 3 3.1-13 Amendment No. 221 (Unit 2)
Amendment No. 218 (Unit3)
INTENTIONALLY BLANK Amendment No. 221 (Unit 1)
OCONEE UNITS 1, 2, & 3 3.121 Amendment No. 221 (Unit 2)
Amendment No. 218 (Unit 3)
INTENTIONALLY BLANK Amendment No. 221 (Unit 1)