Correction to Amendment No. 207, Request for Changing Five Technical Specifications Allowable Levels
ML16132A194
Person / Time
Site: Grand Gulf 
Issue date: 05/26/2016
From: James Kim
Plant Licensing Branch IV
To:
Entergy Operations
Kim J
References
CAC MF4693
Download: ML16132A194 (7)


Text

Vice President, Operations Entergy Operations, Inc.

Grand Gulf Nuclear Station P.O. Box 756 Port Gibson, MS 39150 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 26, 2016

SUBJECT:

GRAND GULF NUCLEAR STATION, UNIT 1 - CORRECTION TO AMENDMENT NO. 207, RE: REQUEST FOR CHANGING FIVE TECHNICAL SPECIFICATIONS ALLOWABLE VALUES (CAC NO. MF4693)

Dear Sir or Madam:

By letter dated August 31, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15195A355), the U.S. Nuclear Regulatory Commission issued Amendment No. 207 to Facility Operating License No. NPF-29 for the Grand Gulf Nuclear Station, Unit 1 (GGNS). This amendment consisted of changes to the Technical Specifications (TS) in response to Entergy Operations, lnc.'s application dated August 1, 2014 (ADAMS Accession No. ML14216A383), as supplemented by letters dated March 3, 2015, and June 30, 2015 (ADAMS Accession Nos. ML15063A279 and ML15181A152, respectively).

The amendment revised the following five non-conservative Technical Specification Allowable Values (AVs) in the GGNS TSs:

Automatic Depressurization System Initiation Timer (TS Table 3.3.5.1-1)

System A and B Containment Spray Timers (TS Table 3.3.6.3-1)

Division 1and2 Degraded 4.16 kiloVolt (kV) Bus Voltage (TS Table 3.3.8.1-1)

Division 3 Degraded 4.16 kV Bus Voltage (TS Table 3.3.8.1-1)

Division 3 Degraded 4.16 kV Bus Voltage Time Delay-LOCA (Loss of Coolant Accident)

(TS Table 3.3.8.1-1)

Subsequent to issuance of the amendment, typographical errors were discovered on TS pages 3.3-42, 3.3-43, 3.3-66, and 3.3-79 of the amendment. The footnote (d), under the "Applicable Modes or Other Specified Conditions" title, was not superscripted on TS pages 3.3-42 and 3.3-43, and the letter "c" needs to be replaced with "-" in several places under the "Function" title. On TS pages 3.3-66 and 3.3-79, the letter "c" needs to be replaced with "-"

in several places under the "FUNCTION" title. These corrections are editorial in nature and do not affect the previously issued safety evaluation of the amendment.

In addition, TS page 3.3-79, regarding Division 3-4.16 kV Emergency Bus Undervoltage, Degraded Voltage - Time Delay, LOCA (TS Table 3.3.8.1-1 (Item 2.e)), new AV of 3.68 seconds was not revised on the Table 3.3.8.1-1 (Item 2.e). In the safety evaluation of the amendment, the NRC staff evaluated and confirmed a proposed AV of 3.68 seconds for the Division 3 Degraded 4.16 kV Bus Voltage time delay.

Enclosed are the revised TS pages 3.3-42, 3.3-43, 3.3-66, and 3.3-79. If you have any questions regarding this matter, please contact me at 301-415-4125 or by e-mail at James.Kim@nrc.gov.

Docket No. 50-416

Enclosure:

Corrected TS pages 3.3-42, 3.3-43, 3.3-66 3.3-79 for Amendment No. 207 cc w/encl: Distribution via Listserv Sincerely, James Kim, Project Manager Plant Licensing IV-2 and Decommissioning Transition Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 4 of 5)

Emergency Core Cooling System Instrumentation FUNCTION

4. Automatic Depressurization System (ADS)

Trip System A APPLICABLE MODES OR OTHER SPECIFIED CONDITIONS REQUIRED CHANNELS PER FUNCTION

a. Reactor Vessel l,2(d),3(d) 2 Water Level -

Low Low Low, Level 1

b. Drywell 1,2(d),3(d) 2 Pressure - High
c. ADS Initiation 1,2(d),3(d) 1 Timer
d. Reactor Vessel 1,2(d),3(d) 1 Water Level -

Low, Level 3 (Confirmatory)

e. LPCS Pump l,2(d),3(d) 2 Discharge Pressure - High
f. LPCI Pump A l,2(d),3(d) 2 Discharge Pressure - High
g. ADS Bypass l,2(d),3(d) 2 Timer (High Drywell Pressure)
h. Manual l,2(d),3(d) 2/system Initiation CONDITIONS REFERENCED FROM REQUIRED ACTION A.1 F

F G

F G

G G

G (d) With reactor steam dome pressure > 150 psig.

GRAND GULF 3.3-42 SURVEILLANCE REQUIREMENTS ALLOWABLE VALUE SR 3.3.5.1.1 2 -152.5 inches SR 3.3.5.1.2 SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6 SR 3.3.5.1.1 s 1.44 psig SR 3.3.5.1.2 SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6 SR 3.3.5.1.2 s 115 seconds SR 3.3.5.1.4 SR 3.3.5.1.6 SR 3. 3. 5. 1. 1 2 10. 8 inches SR 3.3.5.1.2 SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6 SR

3. 3. 5. 1. 1 2 125 psig and SR 3.3.5.1.2 s 165 psig SR 3. 3. 5. 1. 3 SR 3.3.5.1.5 SR 3.3.5.1.6 SR 3.3.5.1.1 2 115 psig and SR 3.3.5.1.2 s 135 psig SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6 SR
3. 3. 5. 1. 2 s 9. 4 minutes SR 3.3.5.1.4 SR 3.3.5.1.6 SR
3. 3. 5. 1. 6 NA (continued)

Amendment No. ~. 207

ECCS Instrumentation 3.3.5. I Table 3.3.5.1-1 (page 5 of 5)

Emergency Core Cooling System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS FUNCTION ACTION A.1 REQUIREMENTS VALUE

5. ADS Trip System B
a. Reactor Vessel 1,2(d),3(d) 2 F

SR 3.3.5.1.1 2 -152.5 Water Level - Low SR 3.3.5.1.2 inches Low Low, Level 1 SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6

b. Drywell Pressure -

1,2(d),3(d) 2 F

SR 3.3.5.1.1

1. 44 psig High SR 3.3.5.1.2 SR 3.3.5.1.3 SR 3.3.5.1.5 SR 3.3.5.1.6
c. ADS Initiation 1,2(d),3(d) 1 G

SR 3.3.5.1.2

115 seconds!

Timer SR 3.3.5.1.4 SR 3.3.5.1.6

d. Reactor Vessel 1,2(d),3(d) 1 F

SR 3.3.5.1.1 2 10.8 inches Water Level -

SR 3.3.5.1.2 Low, Level 3 SR 3.3.5.1.3 (Confirmatory)

SR 3.3.5.1.5 SR 3.3.5.1.6

e. LPCI Pumps B & c 1,2(d),3(d) 2 per G

SR 3.3.5.1.1 2 115 psig Discharge pump SR 3.3.5.1.2 and Pressure -High SR 3.3.5.1.3

135 psig SR 3.3.5.1.5 SR 3.3.5.1.6
f. ADS Bygass Timer 1,2(d),3(d) 2 G

SR 3.3.5.1.2

9. 4 minutes (High rywell SR 3.3.5.1.4 Pressure SR 3.3.5.1.6
g. Manual Initiation 1,2(d),3(d) 2/system G

SR 3.3.5.1.6 NA (d) With reactor steam dome pressure > 150 psig.

GRAND GULF 3.3-43 Amendment No. ~. 207

RHR Containment Spray System Instrumentation 3.3.6.3 Table 3.3.6.3-1 (page 1 of 1)

RHR Containment Spray System Instrumentation FUNCTION

1. Drywell Pressure -

High

2. Containment Pressure-High
3. Reactor Vessel Water Level-Low Low Low, Level 1
4. System A and System B Timers GRAND GULF REQUIRED CHANNELS PER TRIP SYSTEM 2

1 2

CONDITIONS REFERENCED FROM REQUIRED ACTION A.1 B

c B

1 c

SURVEILLANCE REQUIREMENTS SR 3.3.6.3.1 SR 3.3.6.3.2 SR 3.3.6.3.3 SR 3.3.6.3.5 SR 3.3.6.3.6 SR 3.3.6.3.1 SR 3.3.6.3.2 SR 3.3.6.3.3 SR 3.3.6.3.5 SR 3.3.6.3.6 SR 3.3.6.3.1 SR 3.3.6.3.2 SR 3.3.6.3.3 SR 3.3.6.3.5 SR 3.3.6.3.6 SR 3.3.6.3.2 SR 3.3.6.3.4 SR 3.3.6.3.6 ALLOWABLE VALUE 1.44 psig 8.34 psig

-152.5 inches 10.6 minutes

11. 1 minutes and 3.3-66 Amendment No. ~. 207
1.
2.

Table 3.3.8.1-1 (page 1 of 1)

Loss of Power Instrumentation FUNCTION Divisions 1 and 2 -

4.16 kV Emergency Bus Undervoltage

a. Loss of Voltage - 4.16 kV basis
b. Loss of Voltage - Time Delay
c. Degraded Voltage - 4.16 kV basis
d. Degraded Voltage - Time Delay Division 3 - 4.16 kV Emergency Bus Undervoltage
a. Loss of Voltage - 4.16 kV basis
b. Loss of Voltage -

Time Delay

c. Degraded Voltage - 4.16 kV basis
d. Degraded Voltage - Time Delay, No LOCA
e. Degraded Voltage - Time Delay, LOCA REQUIRED CHANNELS PER DIVISION 4

2 4

2 4

2 4

2 4

SURVEILLANCE REQUIREMENTS SR 3.3.8.1.1 SR 3.3.8.1.2 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.1 SR 3.3.8.1.2 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 SR 3.3.8.1.3 SR 3.3.8.1.4 GRAND GULF 3.3-79 LOP Instrumentation 3.3.8.1 ALLOWABLE VALUE

2621 V and 5 2912 v
0.4 seconds and 51.0 seconds
3764.25 V and 53837.6 V
8.5 seconds and 59.5 seconds
2984 V and 53106 V
2.0 seconds and 52.5 seconds
3605 V and 53763.5 v
4. 5 minutes and 55.5 minutes
3.68 seconds and 54.4 seconds Amendment No. H-B-,

-3:-9--9--;- 207 Enclosed are the revised TS pages 3.3-42, 3.3-43, 3.3-66, and 3.3-79. If you have any questions regarding this matter, please contact me at 301-415-4125 or by e-mail at James.Kim@nrc.gov.

Docket No. 50-416

Enclosure:

Corrected TS pages 3.3-42, 3.3-43, 3.3-66 3.3-79 for Amendment No. 207 cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL4-2 R/F RidsACRS_MailCenter Resource RidsNrrDorlDpr Resource RidsNrrDorllpl4-2 Resource RidsNrrLAPBlechman Resource RidsNrrPMGrandGulf Resource RidsRgn4MailCenter Resource ADAMS Accession No.: ML16132A194 Sincerely, IRA/

James Kim, Project Manager Plant Licensing IV-2 and Decommissioning Transition Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation OFFICE DORL/LPL4-2/PM DORL/LPL4-2/LA DORL/LPL4-2/BC DORL/LPL4-2/PM NAME JKim PBlechman MKhanna JKim DATE 5/25/2016 5/25/2016 5/25/2016 5/26/2016 OFFICIAL AGENCY RECORD