ML16106A219
| ML16106A219 | |
| Person / Time | |
|---|---|
| Site: | Byron, Braidwood (NPF-037, NPF-066, NPF-072, NPF-077) |
| Issue date: | 04/15/2016 |
| From: | Gullott D Exelon Generation Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| GL-04-002, RS-16-081 | |
| Download: ML16106A219 (94) | |
Text
RS-16-081 April 15, 2016 10 CFR 50.54(f)
U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Braidwood Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457 Byron Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455 Revision to Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)
References:
(1)
Letter from D. M. Gullatt (Exelon Generation Company, LLC) to US NRC, "Plant-Specific Path and Schedule for Resolution of Generic Letter 2004-02,"
dated May 14, 2013 (2)
Letter from S. Bahadur (NRC) to W. A. Nowinowski (PWR Owners Group),
"Final Safety Evaluation for Pressurized Water Reactor Owners Group Topical Report WCAP-16793-NP, Revision 2, 'Evaluation of Long-Term Cooling Considering Particulate Fibrous and Chemical Debris in the Recirculating Fluid,"' dated April 8, 2013 (3)
Letter from D. M. Gullatt (Exelon Generation Company, LLC) to US NRC, "Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)," dated October 30, 2015 In Reference 1, Exelon Generation Company, LLC (EGC) stated that the only remaining open issue related to the resolution of GSl-191 was in-vessel downstream effects; and presented a resolution plan to close this issue. In-vessel downstream effects refers to post-accident debris in the recirculated water in containment, bypassing the recirculation sump strainers, and accumulating at the bottom of the fuel assemblies, having potential to reduce cooling flow to the core and degrading long term core cooling.
As noted in Reference 1, to address in-vessel downstream effects, Braidwood Station and Byron Station would use the acceptance criteria of 15 grams of fiber per fuel assembly specified in WCAP-16793-NP Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid." WCAP-16793 documents the results of industry debris head loss testing on a typical Westinghouse fuel assembly and sets acceptance criteria for debris loading to ensure long term core cooling is maintained.
April 15, 2015 U.S. Nuclear Regulatory Commission Page2 EGC committed to completing the resolution plan by documenting the quantity of fibrous debris that reaches the sump strainers; and verifying compliance with the limitations and conditions specified in the NRC Safety Evaluation (Reference 2) associated with WCAP-16793-NP Revision 2. This information was provided to the NRC in Reference 3.
During the subsequent review of Reference 3, the NRC inquired into the basis for the fiber bypass value used to determine the in-vessel fiber loading (i.e., grams of fiber per fuel assembly). EGC explained that the fiber bypass value was based on the Byron and Braidwood Stations' specific testing that utilized grab samples to determine strainer bypass. Subsequently, due to questions regarding the reliability of this method, EGC elected to utilize a different method to determine a new design basis fiber bypass fraction for Byron and Braidwood Stations.
Based on the similarities in strainer design, debris load, and penetration velocity between Byron, Braidwood, Salem and Palo Verde Stations; bypass testing data for Salem and Palo Verde Stations were used to determine a revised conservative bypass fraction for Byron and Braidwood Stations of 30%. The in-vessel fiber loading was calculated to be 11.9 grams/fuel assembly using a 30% bypass fraction and a transport fraction to the strainer of 75%, meeting the acceptance criteria of 15 grams/fuel assembly specified in WCAP-16793-NP Revision 2. The details of the methodology used to calculate the in-vessel fiber loading are provided in Attachment A, "Fiber Bypass Fraction and Grams of Fiber per Fuel Assembly," of Attachment 1, Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 1, "Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP." Note that attached Design Analysis 2014-04466, Revision 1, supersedes Design Analysis 2014-04466, Revision 0, submitted with Reference 3, in its entirety.
If you have any questions or require additional information regarding this submittal, please contact Joseph A. Bauer at (630) 657-2804.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 15th day of April 2016.
Respectfully, David M. Gullett Manager - Licensing Exelon Generation Company, LLC
Attachment:
Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 1, Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP cc:
USNRC Region Ill, Regional Administrator USN RC Senior Resident Inspector, Braidwood Station USNRC Senior Resident Inspector, Byron Station
ATTACHMENT 1 Braidwood Station and Byron Station Design Analysis 2014-04466, Revision 1 Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)
Exelon~
Ce-AA40940U1 Revision 8 Design Analysis Analysis No.: 1 Nuclear ATfA~MeNT1 Design Analysis Major Revision Cover She-1 Pagel Last Page No. 8 15, Attachment D! f)a(JQ 028 2014-04466 Revision:*
1 Major 181 MlnorO
Title:
3 Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793--NP ECIECFl No.: 4 405352 (Braidwood), 405357(Byron)
Revision: 5 0,0
- station(s)i 7
- Byron/Braidwood Qomponent(a):
Unit No.: 8 1 and2 NIA Discipline: 9 MEDC Descrip. Code/Keyword: 10 M03 Safety/QA Class: 11 SA System Code: 12 SI Structure: 13 N/A CONTAC::>~ ~rm:t=EllEMCES 15
, Document No.:
Fromrro Document No.:
FromfTo WCAP-16793-NP From CN*SEE-1-07-38 From CN..CRA* 10-54 From BRW-06-0016-M From WCAP-17057 From BYAOS-029 From Js this Design Analysis Safeguards ~fot"maCion't&
YesQ No.21 If yes, see SY-AA-101-106 Does this Dfffgn Aril(pfS. contilfi'I Unverified AHumptfoJQl?17
~""'"~-
YeeQ tlo fgJ If~. ATl/AA#:
This o **.,.,.yaitt$UPE.RCEDES:14 NIA in its~~
. Qesc:tiptlOn ofRevisi011'(1lst chat'lged pages When ar pages at original analysis were notchang9(1}:...
Revlslon 1 changes the method for calculating the fiber bypass fraction. The fiber load is calculated to be below the limit of 15 glfuel assembly. Revision 1 also references the results of Revision 3 to design analysis CN-SEE-1-07-38.
Preparer: 1111 H.Kopk~
See Satfl!'flt, & lttnciY'Document
~-Prfrtt~
,Signtlam*
Data M81hod of Review: 21 'netaled Riivrew a Al...
¢.1oufatioits(attached)0 Testing t:'J ReVhiwer:.,.
E. Decristofaro, S. Paartberg See Sargent & Lundy Document Print Name Sign Name
.Dl1tlt RBvlew Notes: a:i Independent review 1&1 Peer review D
(~Ellltft'll!!~ung; E"'8maf Approver:;. 20 A.Peterson See Sargent & Lundy Document Print Name Sign Name Dale See Owner Exetan ReViewarr 25 See Owner Review Record, Review Record, page II See Owner Aevlew'Rec;ottf, p~e II
.Paga II
- ~*
., ~rlnt Name Signt.lama
- oate lntt.-CJ,mt31117Party ~evifW Reqd?'26 Yes[J Nol fl_._
f.f!N/)bl'
~011 Approver: 21 J.Cunzeman PJ:fr}t~
(
'/
llP'ililame
~*
Calculation #2014-04466 Revision 1 Page II Exelon Owner Review Record Design Analysis: 2014-044§6 Revision 1 Design Analysis
Title:
Assessment of the NRC:: Safety Evajµation Limitations and Conditions Associated with WC::AP-16793-NP 1
Exelon Reviewers:
Giovanni Panici <Braid wood)
Print Name Kevin Dhaese <Byron)
Print Name
~Name Sign Name
'-1. 14. ~6 Date
DESIGN ANALYSIS TABLE OF CONTENTS Analysis No. 2014-04466 Rev. No. 1 Page No. HA SECTION:
PAGE NO.
SUB-PAGE NO.
Design Analysis Cover Sheet I
Owner Acceptance Review Record II Table of Contents llA Owner Acceptance Review (Not included in this document as these pages are proprietary to Exelon Generation llB II B, !IC, llD Company)
External Analysis 2014-04466 Revision 1 1
1-15 Attachment A - Fiber Bypass Fraction and Grams of Fiber per A1 A1-A.2-12 Fuel Assembly Calculation Attachment B - Available Driving Head Calculation B1 B1-B3 Attachment C - Maximum Flow Rate per Fuel Assembly C1 C1 Calculation Attachment D - Exelon Power lab Report-Sump Strainer D1 01-028 Particle Loading.
Lundy***
DESIGN CONTROL
SUMMARY
CLIENT:
Exelon UNIT:
1&2 PAGE NO.:
l PROJECT NAME:
Byron/Braidwood S&L NUCLEAR QA PROGRAM PROJECT NO.:
11332-194 APPLICABLE 181 YES 0 NO CALC. NO.. :
2014-04466 SAFETY RELATED 181 YES 0 NO TITLE:
Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP EQUIPMENT NO.:
IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD Initial issue (47 pages). This calculation supplements Calculation Note INPUTS/ ASSUMPTIONS CN-SEE-I-07-38.
181 VERIFIED 0
UNVERIFIED REVIEW METHOD:
Detailed Review REV.:
0 STATUS:
181 APPROVED 0 SUPERSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
07/14/2015 PREPARER:
Eric R. DeCristofaro (Signature on file)
DATE:
12/05/2014 REVIEWER:
Matthew M. Ross (Signature on file)
DATE:
12/05/2014 REVIEWER:
Helmut R. Kopke (Signature on file)
DATE:
12/05/2014 (Client Comment Incorporation)
APPROVER:
Robert J. Peterson (Signature on file)
DATE:
07/1412015 IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD Calculation revised to update the design basis fiber bypass, and hence the in-vessel fiber loading (grams of fiber per fuel assembly or g/FA).
Changes to main body tracked with revision bars. Attachment A revised in Its entirety. Attachments B, C, and Dare INPUTS/ ASSUMPTIONS unchanged.
181 VERIFIED 88 Total Pages.
0 UNVERIFIED REVIEW METHOD:
Detailed Review REV.:
1 STATUS:
.MAPPROVED 0 SUPEflSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
'1~l5.-Lb PREPARER:
Helmut R. Kopke 71#£.!t--
DATE: q._-t3-2..0l6 REVIEWER:
Eric R. DeCristofaro c
~,/,/.., _.-
DATE: !:J.- IS -;},p/6 REVIEWER:
Stephen J. Paarlberg (2nd Round OAR Comments Only)
~_:; --
1/
DATE: *-W. I b APPROVER:
Robert J. Peterson M\\h-:..1 tL~.~
{./
DATE:
_ M IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD INPUTS/ ASSUMPTIONS 0
VERIFIED 0
UNVERIFIED REVIEW METHOD:
REV.:
STATUS:
0APPROVED 0 SUPERSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
PREPARER:
DATE:
REVIEWER:
DATE:
APPROVER:
DATE:
Calculation 2014-04466 Revision 1 Table of Contents Page 2of15 Page Cover Page........................................................................................................................... 1 Table of Contents................................................................................................................. 2 1.0 Background and Purpose.............................................................................................. 3 2.0 References..................................................................................................................... 4 3.0 Limitations and Conditions to the use ofWCAP-16793-NP, Rev. 2........................... 7 4.0 Conclusions................................................................................................................. 15
- of Pages Attachment A: Fiber Bypass Fraction and Grams of Fiber Per Fuel Assembly Calculation................................................................................................ 41 Attachment B: Available Driving Head...............................................................................3 Attachment C: Maximum Flow Rate Per Fuel Assembly................................................... 1 Attachment D: Exelon Power Labs Report (Ref. 2.19)..................................................... 28 List of Affected Sections Main body (all pages)
Attachment A (all pages)
Attachment B Attachment C Attachment D Revision 1 Revision 1 Revision 0 Revision 0 Revision 0
Calculation 2014-04466 Revision 1
1.0 BACKGROUND
AND PURPOSE Page 3 of15 The current Byron and Braidwood in-vessel effects analysis is documented in Westinghouse Calculation Note CN-SEE-1-07-38, Revision 3, "LOCADM Analysis." This calculation is based on Revision 2 of WCAP-16793-NP, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid." The calculation presents the results of the LOCADM analysis (maximum deposition thickness and fuel cladding temperature),
but does not address the limitations and conditions presented in Section 4.0 of the NRC Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2. Also, Appendix B of Calculation Note CN-SEE-1-07-38 contains an assessment of fuel blockage due to fibrous debris which is "no longer applicable" per the verbiage in the appendix.
The purpose of this calculation is to addresses the fourteen limitations and conditions presented in Section 4.0 of the NRC Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2, for Byron and Braidwood. These limitations and conditions are to be addressed by licensees as part of their response to the NRC to in-vessel long term core cooling concerns. As a part of addressing these limitations the following additional information is determined:
Attachment A calculates the fiber bypass fraction and grams of fiber per fuel assembly.
Attachment B calculates the available driving head.
Attachment C calculates the maximum flow rate per fuel assembly.
Revision 1 of this calculation updates the method used to determine the design basis fiber bypass quantity. The revised fiber bypass results in a change to the in-vessel fiber quantity (grams of fiber per fuel assembly).
Calculation 2014-04466 Revision 1
2.0 REFERENCES
Page 4of15 2.1 Safety Evaluation by the Office of Nuclear Reactor Regulation to WCAP-16793-NP, Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," October 2011 (ADAMS Accession No. ML12084A154). Transmitted via Jetter from Sher Bahadur (NRC) to Anthony Nowinowski (PWR Owners Group), on April 8, 2013, (ADAMS Accession No. ML13084A152)).
2.2 Drawing 113E977 2.2.1 Braidwood Units 1 & 2, Sheet 1, Rev. 5, "4 Loop Reactor Vessel Units 1 &
2."
2.2.2 Byron Units 1 & 2, Sheet 1, Rev. 5, "4-Loop 173.000 I.D. Reactor Vessel."
2.3 Drawing M-196 2.3.1 Byron Unit 1, Sheet 1, Rev. M, "Reactor Coolant Loop Piping Arrangement and Weld Details."
2.3.2 Byron Unit 2, Sheet 2, Rev H, "Reactor Coolant Loop Piping Arrangement" 2.3.3 Braidwood Unit 1, Sheet 1, Rev. N, "Reactor Coolant Loop Piping Arrangement Unit 1" 2.3.4 Braidwood Unit 2, Sheet 2, Rev. H, "Reactor Coolant Loop Piping Arrangement" 2.4 Calculation Note Number CN-CRA-10-54, Rev. 2 (Braidwood), Rev. 1 (Byron),
"Byron/Braidwood Units 1 and 2 LOCA Long-Term M&E and Containment Re-Analysis for IR Issues Identified in 2010."
2.5 ASME Steam Tables, 1967.
2.6 WCAP-17057-P, Rev. 1, "GSI-191 Fuel Assembly Test Report for PWROG."
2.7 Pressurized Water Reactor Owners Group (PWROG), Topical Report (TR) WCAP-16793-NP, Rev. 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," Dated July, 2013.
2.8 Arey, M., PWROG letter to Document Control Desk, NRC, "PWROG Response to Request for Additional Information Regarding Topical Report WCAP-16793-NP, Revision 1, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," (PA-SEE-0312)," August 9, 2010 (ADAMS Accession No. ML102230031).
2.9 Byron/Braidwood UFSAR, Revision 15, Tables 4.1-1 and 5.4-5.
2.10 Steam Generator Support Pad Elevation 2.10.l Braidwood Unit 2 Drawing 2SG-Ol, Rev. A, "Spec L-2907, Inspection Identification Drawing For Inservice Inspection of Steam Generator No.
2RC01BA Loop #1, Unit 2."
2.10.2 Braidwood Unit 2 Drawing 2SG-02, Rev. A, "Spec L-2907, Inspection Identification Dwg. For lnservice Inspection of Steam Generator No.
2RC01BB Loop #2, Unit 2."
2.10.3 Braidwood Unit 2 Drawing 2SG-03, Rev. A, "Spec L-2907, Inspection Identification Dwg. For lnservice Inspection of Steam Generator No.
2RC01BC Loop #3, Unit 2."
2.10.4 Braidwood Unit 2 Drawing 2SG-04, Rev. B, "Spec L-2907, Inspection Identification Dwg. For Inservice Inspection of Steam Generator No.
Calculation 2014-04466 Revision 1 2RC01BD Loop #4, Unit 2."
Page S of lS 2.10.S Byron Unit 2 Drawing 2SG-l-ISI, Rev. B, Sheet 1, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BA."
2.10.6 Byron Unit 2 Drawing 2SG-1-ISI, Rev. A, Sheet 3, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BB."
2.10.7 Byron Unit 2 Drawing 2SG-l-ISI, Rev. C, Sheet 2, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BC."
2.10.8 Byron Unit 2 Drawing 2SG-l-ISI, Rev. A, Sheet 4, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BD."
2.10.9 Byron and Braidwood Unit 2, "Vertical Steam Generator Instructions,"
January 1980.
2.10.10 Drawing 7720E001, Rev. 6, "Steam Generator Arrangement" 2.11 Calculation No. BYR06-029 I BRW-06-0016-M, Rev. S, "SI/RHR/CS/CV System Hydraulic Analysis in Support of GSI-191." Byron currently uses Rev. S, and Braidwood uses Revs.Sand SA. The information used herein is from Rev.Sand is not impacted by Rev. SA.
2.12 Braidwood EC 38960S, Rev. 1, "Westinghouse 17Xl 7 OFA Fuel Changes; Robust P-Grid and Standardized Debris Filter Bottom Nozzle."
2.13 Byron EC 388707, Rev. 0, "Westinghouse 17Xl 7 OFA Fuel Changes; Robust P-Grid and Standardized Debris Filter Bottom Nozzle."
2.14 CCI Test Specification Q.003.84 748, Revision 3, "Containment Sump Strainer Replacement: Large Size Filter Performance Test."
2.lS TODI NF12002S7, Rev. 0, "Byron Unit 2 Cycle 18 Non-MUR Reload Design Initialization."
2.16 TODI NFll 0040S, Rev. 1, "Byron Unit 1 Cycle 19 Reload Design Initialization."
2.17 TODI NF1300006, Rev 0, "Braidwood Unit 1 Cycle 18 Reload Design Initialization" 2.18 TODI NF1300169, Rev. 0, "Braidwood Unit 2 Cycle 18 Reload Design Initialization."
2.19 Exelon Power Labs Report, "Sump Strainer Particle Loading," 02/01/2006. (see Attachment D) 2.20 CCI Report 680/41134, Rev. 3, "Large Size Filter Performance Test."
2.21 Letter from J. Butler (NEI) to S. Bailey (NRC),
Subject:
Fibrous Debris Preparation Procedure for ECCS Recirculation Sump Strainer Testing, Revision 1, dated January 30, 2012 (ADAMS Accession No. ML1204810S2), including Attachment entitled, "ZOI Fibrous Debris Preparation: Processing, Storage and Handling,"
Revision 1, January 2012, (ADAMS Accession No. ML1204810S7).
2.22 Calculation Note Number CN-SEE-1-07-38, Rev. 3, "LOCADM Analysis for Byron/Braidwood Units 1 and 2."
2.23 Calculation No. BRW-OS-OOS9-M I BYROS-041, Rev. 2, "GSl-191 Post-LOCA Debris Generation."
Calculation 2014-04466 Revision 1 Page 6of15 2.24 PSEG Letter No. LR-N13-0091 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Responses to NRC Questions Regarding Salem Bypass Testing, dated April 22, 2013. ADAMS Accession No. ML13114A048.
2.25 NRC Letter (John G. Lamb) to PSEG (Thomas Joyce),
Subject:
Salem Nuclear Generating Station, Units 1 and 2 - Close-out of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors" (TAC Nos. MC4712 and MC4713),
dated April 30, 2014. ADAMS Accession No. ML14113A202.
2.26 U.S. Nuclear Regulatory Commission Staff Review of the Documentation Provided by PSEG Nuclear, LLC, for Salem Nuclear Generating Station, Units 1 and 2, Concerning Resolution of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors." ADAMS Accession No. ML14113A221.
The following Byron/Braidwood drawing and calculation References were verified as current in PASSPORT on 2/10/2016: 2.2, 2.3, 2.4, 2.10, 2.11, and 2.23.
Calculation 2014-04466 Revision 1 Page 7of15 3.0 Limitations and Conditions to the use ofWCAP-16793-NP, Rev. 2 Section 4.0 of the SER for WCAP-16793 [Ref. 2.1] lists fourteen limitations and conditions that are to be addressed by licensees as part of their response to in-vessel long term core cooling concerns. These limitations are addressed individually in Sections 3.1 through 3.14 of this calculation.
3.1 Limitation 1 Limitation 1 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should corifirm that their plants are covered by the PWROG sponsored fuel assembly tests by confirming that the plant available hot-leg break driving head is equal to or greater than that determined as limiting in the proprietary fuel assembly tests and that flow rate is bounded by the testing. Licensees should validate that the fuel types and inlet filters in use at the plant are covered by the test program (with the exception of LTAs).
Licensees should limit the amount of fibrous debris reaching the fuel inlet to that stated in Section JO of the WCAP (I 5 grams per fuel assembly for a hot-leg break scenario).
Alternately, licensees may perform plant specific testing and/or evaluations to increase the debris limits on a site-specific basis. The available driving head should be calculated based on the core exit void fraction and loop flow resistance values contained in their plant design basis calculations, considering clean loop flow resistance and a range of break locations.
Calculations of available driving head should account for the potential for voiding in the steam generator tubes. These tests shall evaluate the effects of increased fiber on flow to the core, and precipitation of boron during a postulated cold-leg break, and the effect ofplfratios below 1:1. The NRC staff will review plant specific evaluations, including hot-and cold-leg break scenarios, to ensure that acceptable justification for higher debris limits is provided. (Sections 3.1.2 (c), 3.1.2 (e), 3.3.1, 3.4.2, 3.8, 3.9 and 3.10 of this SE)."
It is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. In addition, the available hot-leg break driving head is calculated in Attachment B to be between 13.2 and 14.2 psi for Byron and Braidwood Units 1 and 2. This is much greater than the maximum measured debris head loss during PWROG fuel assembly testing of 2.7 psi [Bullet 1 on page 6-51 of Ref. 2.6].
The maximum flow rate per fuel assembly during cold-leg injection at Byron and Braidwood is 43.6 gpm (see Attachment C). This flow rate is bounded by the maximum flow rate of 44.7 gpm per fuel assembly used in the Westinghouse and Areva testing [Table G-2 and G-3 of Ref. 2.7]. Thus, the hot-leg break available
Calculation 2014-04466 Revision 1 Page 8of15 driving head is greater than the debris head loss measured during the fuel assembly blockage test which is the basis for the 15 gram per fuel assembly limit.
In addition, Byron/Braidwood has Westinghouse fuel with a Robust P-grid design
[Refs. 2.15, 2.16, 2.17 and 2.18]. The Robust P-grid design was evaluated in Braidwood EC 389605 [page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
Per the above discussion, Limitation 1 is met.
3.2 Limitation 2 Limitation 2 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Each licensee's GL 2004-02 submittal to the NRC should state the available driving head used in the evaluation of the hot-leg break scenario, the ECCS flow rates, and the results of the LOCADM calculations.
Licensees should provide the type(s) of fuel and inlet filters installed in their plants, as well as the amount of fiber (gram per fuel assembly) that reaches the core. (Section 3. 3.1 and 3.10 of this SE) "
The available hot-leg break driving head is calculated in Attachment B to be between 13.2 and 14.2 psi for Byron and Braidwood Units 1 and 2. This is much greater than the maximum measured debris head loss during PWROG fuel assembly testing of 2.7 psi [Bullet 1 on page 6-51 of Ref. 2.6]. The maximum flow rate per fuel assembly at Byron and Braidwood is 43.6 gpm (See Attachment C). This flow rate is bounded by the maximum flow rate of 44. 7 gpm per fuel assembly used in the Westinghouse and Areva testing [Table G-2 and G-3 of Ref. 2.7]. Thus, the hot-leg break available driving head at Byron I Braidwood is greater than the debris head loss measured during the fuel assembly blockage test which is the basis for the 15 gram per fuel assembly limit.
Byron/Braidwood has Westinghouse fuel with a Robust P-grid design [Refs. 2.15, 2.16, 2.17 and 2.18]. The Robust P-grid design was evaluated in Braidwood EC 389605 [page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris
Calculation 2014-04466 Revision 1 Page 9of15 Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
It is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. The results of the LOCADM calculations are provided in Calculation Note Number CN-SEE-I-07-38 [Ref. 2.22] and are repeated in Table 3.1.
T bl 3 1 LOCADM R I S a e. :
esu ts ummarv Parameter Value Acceptance Criteria Maximum Cladding Temperature
< 620°F
< 800°F Maximum Total Deposition Thickness
< 18 mil
< 50 mil Per the above discussion, Limitation 2 is met.
3.3 Limitation 3 Limitation 3 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Section 3.1.4.3 of the WCAP states that alternate flow paths in the RPV were not credited The section also states that plants may be able to credit alternate flow paths for demonstrating adequate LTCC. If a licensee chooses to take credit for alternate flow paths, such as core baffle plate holes, to justify greater than 15 grams of bypassed fiber per fuel assembly, the licensee should demonstrate, by testing or analysis, that the flow paths would be effective, that the flow holes will not become blocked with debris during a LOCA, that boron precipitation is considered, and that debris will not deposit in other locations after passing through the alternate flow path such that LTCC would be jeopardized (Sections 3.3.1 and 3.4.2 of this SE)"
Limitation 3 is met because no alternative flow paths through the core are credited.
3.4 Limitation 4 Limitation 4 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Sections 3.2 and 3.3 of the WCAP provide evaluations to show that even with large blockages at the core inlet, adequate flow will enter the core to maintain LTCC. The staff recognizes that these calculations show that significant head loss can occur while maintaining adequate flow. However, the analyses have not been correlated with debris amounts. Therefore, the analyses cannot be relied upon to demonstrate adequate LTCC. (Sections 3.3. 3 and 3.4 of this SE) "
Calculation 2014-04466 Revision 1 Page 10of15 Limitation 4 is met because it is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. In addition, the evaluations provided in Sections 3.2 and 3.3 ofWCAP-16793 are not used.
3.5 Limitation 5 Limitation 5 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"In RAJ Response number 18 in Reference 13, the PWROG states that numerical analyses demonstrated that, even if a large blockage occurs, decay heat removal will continue. The NRC staff's position is that a plant must maintain its debris load within the limits defined by the testing (e.g.,
15 grams per assembly). Any debris amounts greater than those justified by generic testing in this WCAP must be justified on a plant-specific basis.
(Sections 3.4.2 and 3.10 of this SE)"
Limitation 5 is met because it is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly.
3.6 Limitation 6 Limitation 6 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"The fibrous debris acceptance criteria contained in the WCAP may be applied to fuel designs evaluated in the WCAP. Because new or evolving fuel designs may have different inlet fittings or grid straps that could exhibit different debris capture characteristics, licensees should evaluate fuel design changes in accordance with 10 CFR 50.59 to ensure that new designs do not impact adequate long term core cooling following a LOCA.
(Section 3.4.2 of this SE)"
Limitation 6 is met because the Byron/Braidwood Westinghouse fuel with Robust P-grid design [Refs. 2.15, 2.16, 2.17, 2.18] is evaluated in Braidwood EC 389605
[page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
Calculation 2014-04466 Revision 1
- 3. 7 Limitation 7 Page 11 of15 Limitation 7 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Sections 2 and 4.3 of the WCAP establish 800 degrees Fahrenheit as the acceptance limit for fuel cladding temperature qfter the core has been re-flooded. The NRC staff accepts a cladding temperature limit of 800 degrees Fahrenheit as the long-term cooling acceptance basis for GSl-191 considerations. Each licensee's GL 2004-02 submittal to the NRC should state the peak cladding temperature predicted by the LOCADM analysis. If a licensee calculates a temperature that exceeds 800 degrees Fahrenheit, the licensee must submit data to justify the acceptability of the higher clad temperature. (Sections 3.2, 3.4.3, 3.4.4, and 3.10 of this SE)"
Limitation 7 is met since the LOCADM spreadsheet was used in the Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22] to show that the maximum fuel cladding temperature does not exceed 800 °F. The peak cladding temperature was found using the LOCADM spreadsheet to be less than 620°F [Ref. 2.22].
3.8 Limitation 8 Limitation 8 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"As described in the Limitations and Conditions for WCAP-16530-NP (ADAMS Accession No. ML073520891) (Reference 21), the aluminum release rate equation used in TR WCAP-16530-NP provides a reasonable fit to the total aluminum release for the 30-day ICET tests but under-predicts the aluminum concentrations during the initial active corrosion portion of the test. Actual corrosion of aluminum coupons during the ICET 1 test, which used sodium hydroxide (NaOH), appeared to occur in two stages; active corrosion for the first half of the test followed by passivation of the aluminum during the second half of the test. Therefore, while the 30-day fit to the ICET data is reasonable, the WCAP-16530-NP-A model under-predicts aluminum release by about a factor of two during the active corrosion phase of ICET 1. This is important since the incore LOCADM chemical deposition rates can be much greater during the initial period following a LOCA, if local conditions predict boiling. As stated in WCAP-16530-NP-A, to account for potentially greater amounts of aluminum during the initial days following a LOCA, a licensee 's LOCADM input should apply a factor of 2 increase to the WCAP-16530-NP-A spreadsheet predicted aluminum release, not to exceed the total amount of aluminum predicted by the WCAP-16530-NP-A spreadsheet for 30 days. In other words, the total amount of aluminum released equals that predicted by the WCAP-16530-NP-A spreadsheet, but the timing of the release is accelerated. Alternately, licensees may choose to use a different method for determining aluminum release but licensees should not use an aluminum
Calculation 2014-04466 Revision 1 Page 12of15 release rate equation that, when aqjusted to the ICET 1 pH, under-predicts the aluminum concentrations measured during the initial 15 days of ICET
- 1. (Section 3. 7 of this SE) "
Consistent with the procedure described in Limitation 8, a factor of 2 increase on the surface area of aluminum is used in this analysis (see Section 5.2.1 in Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22]). Therefore, Limitation 8 is met.
3.9 Limitation 9 Limitation 9 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Jn the response to NRC staff RA!s, the PWROG indicated that if plant-specific refinements are made to the WCAP LOCADM base model to reduce conservatisms, the user should demonstrate that the results still adequately bound chemical product generation. If a licensee uses plant-specific refinements to the WCAP-16530-NP-A base model that reduces the chemical source term considered in the downstream analysis, the licensee should provide a technical justification that demonstrates that the refined chemical source term adequately bounds chemical product generation.
This will provide the basis that the reactor vessel deposition calculations are also bounding. (Section 3. 7 of this SE)"
Limitation 9 is met since an unmodified version of the LOCADM spreadsheet was used in Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22] to compute the maximum fuel cladding temperature and the total debris deposition on the fuel rods.
3.10 Limitation 10 Limitation 10 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"The WCAP states that the material with the highest insulating value that could deposit from post-LOCA coolant impurities would be sodium aluminum silicate. The WCAP recommends that a thermal conductivity of 0.11 BTUl(h-ft-°F) be used/or the sodium aluminum silicate scale and/or bounding calculations when there is uncertainty in the type of scale that may form. If plant-specific calculations use a less conservative thermal conductivity value for scale (i.e., greater than 0.11 BTU/(h-ft-°F)), the licensee should provide a technical justification for the plant-specific thermal conductivity value. This justification should demonstrate why it is not possible to form sodium aluminum silicate or other scales with thermal conductivities less than the selected value. (Section 3. 7 of this SE) "
Limitation 10 is met since an unmodified version of the LOCADM spreadsheet with the default thermal conductivity of 0.11 BTU I (h-ft-°F) was used in
Calculation 2014-04466 Revision 1 Page 13of15 Calculation Note Number CN-SEE-I-07-38 [Ref. 2.22] to compute the maximum fuel cladding temperature and the total debris deposition on the fuel rods.
3.11 Limitation 11 Limitation 11 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should demonstrate that the quantity of fibrous debris transported to the fael inlet is less than or equal to the fibrous debris limit specified in the proprietary fuel assembly test reports and approved by this SE. Fiber quantities in excess of 15 grams per fuel assembly must be justified by the licensee. Licensees may determine the quantity of debris that passes through their strainers by (1) performing strainer bypass testing using the plant strainer design, plant-specific debris loads, and plant-specific flow velocities, (2) relying on strainer bypass values developed through strainer bypass testing of the same vendor and same perforation size, prorated to the licensee's plant specific strainer area,*
approach velocity; debris types, and debris quantities, or (3) assuming that the entire quantity of fiber transported to the sump strainer passes through the sump strainer. The licensee's submittals should include the means used to determine the amount of debris that bypasses the ECCS strainer and the fiber loading expected, per fuel assembly, for the cold-leg and hot-leg break scenarios. Licensees of all operating PWRs should provide the debris loads, calculated on a fuel assembly basis, for both the hot-leg and cold-leg break cases in their GL 2004-02 responses. (Section 3.10 of this SE)"
At Byron/Braidwood the fibrous debris generated due to a cold-leg break is the same as for a hot-leg break since the only fiber from both breaks is 100% latent fiber
[Ref. 2.23]. The fiber bypass is determined using testing performed by CCI (the strainer vendor) for other utilities with a CCI strainer with the same perforation size as Byron/Braidwood, as described in Attachment A. The fiber calculated to bypass the strainers and reach the fuel assembly is 11.9 grams per fuel assembly (See Attachment A). This quantity is less than the WCAP-16793-NP acceptance criteria of 15 grams per fuel assembly and therefore Limitation 11 is met.
3.12 Limitation 12 Limitation 12 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Plants that can qualifY a higher fiber load based on the absence of chemical deposits should ensure that tests for their conditions determine limiting head losses using particulate and fiber loads that maximize the head loss with no chemical precipitates included in the tests. (Section 3.3.1 of this SE) Note that in this case, licensees must also evaluate the other considerations discussed in Item 1 above."
Calculation 2014-04466 Revision 1 Page 14of15 Limitation 12 is met because Byron/Braidwood does not utilize a fiber debris limit greater than 15 grams per fuel assembly (See Attachment A).
3.13 Limitation 13 Limitation 13 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should verifY that the size distribution of fibrous debris used in the fuel assembly testing referenced by their plant is representative of the size distribution of fibrous debris expected downstream of the plant's ECCS strainer(s). (Section 3.4.2. J of this SE) "
CCI Report Q.003.83 748 [Ref. 2.14] states the following about fiber preparation "The fibers used in the test should be identical (as far as practical) to that used at Byron/Braidwood Unit 1. The fibers will be decomposed by first cutting with a leaf shredder, manually tearing the shredded fibers into smaller pieces and then soaking the pieces in a water bucket. A water jet is used to separate the fiber in the bucket after it is shredded by the leaf shredder." This fiber preparation method is consistent with CCI's standard method which was found to be substantially consistent with NEI 's recommended fiber preparation procedure [Ref. 2.21].
The results of the Byron I Braidwood specific fiber bypass testing show that the fiber size distribution at Byron I Braidwood ranged from 0.1 mm to greater than 21 mm in length, but were generally in the 0.1 mm to 1 mm range [page 6 of Ref. 2.19]. This is consistent with the fiber size distribution in WCAP-16793-NP
[Ref. 2. 7] which is presented in the table below.
Table 3.2: Fiber B ass Size Cate o (a) 0-0.5 mm 0.5-1 mm
> 1 mm 67-87%
8-28%
0-15%
(a) From page G-8 ofWCAP-16793-NP, Revision 2 [Ref. 2.7]
Therefore, Limitation 13 is met.
Note: Although the NRC had concerns with the total fiber bypass quantity determined in the Byron/Braidwood specific tests due to the bypass quantity being based on grab samples, it is acceptable and common to use grab samples when determining downstream debris size distributions. The NRC accepted the use of grab samples for determining the downstream size distribution of fiber for another utility [Refs. 2.24, 2.25, and 2.26]. Therefore, the use of the Byron/Braidwood specific fiber bypass testing in the response to this limitation is acceptable.
3.14 Limitation 14 Limitation 14 in Section 4.0 of the SER to WCAP-16793 is repeated below:
Calculation 2014-04466 Revision 1 Page 15of15 "The "Margin Calculator," referenced in References 11 and 12, has not been submitted to the NRC under formal letter, and NRC staff has not performed a detailed review of the document. Therefore, NRC staff expects licensees to base their GL 2004-02 invessel effects evaluations on the information provided in the proprietary test reports and associated RAJ responses (References 8, 16, 17, 11 and 12), including the conditions and limitations stated in this SE, and existing plant design-basis calculations and analyses. "
Limitation 14 is met because the "Margin Calculator" is not used.
4.0 CONCLUSION
S Section 4.0 of the SER to WCAP-16793 lists fourteen limitations and conditions that are to be addressed by licensees as part of their response to in-vessel long term core cooling concerns. This calculation addresses each limitation and shows that Byron and Braidwood meet each limitation.
I
Calculation 2014-04466 Revision 1 Attachment A Page Al of Al 7 ATTACHMENT A: FIBER BYPASS FRACTION AND GRAMS OF FIBER PER FUEL ASSEMBLY CALCULATION Note: This attachment contains its own Reference section. Therefore, References in this attachment do not refer to the main body Reference section unless otherwise stated.
1.0 Background I Purpose In October 2015, Exelon submitted Revision 0 of this calculation (2014-04466) to the NRC as part of the closure documentation for GSI-191 [Ref. 16]. Subsequent to this submittal, the NRC inquired into the basis for the fiber bypass value used to determine the in-vessel fiber loading (grams of fiber per fuel assembly). Exelon explained that the fiber bypass value was based upon Byron/Braidwood specific testing that utilized grab samples to determine strainer bypass [Refs. 2.14, 2.19, and 2.20 of main body]. The NRC expressed concern with this method, as it has been established since the time of the Byron/Braidwood testing (2005) that the use of grab samples to determine fiber bypass fraction/quantity can be inaccurate. For this reason, Exelon elected to determine a new design basis fiber bypass fraction for Byron/Braidwood.
The purpose of this attachment is to document the design basis fiber bypass fraction and quantity as well as the resulting in-vessel fiber loading (grams of fiber per fuel assembly).
2.0 Methodology One of the primary reasons that the strainer fiber bypass fraction is important is that it is used to determine the grams of fiber per fuel assembly. The grams of fiber per fuel assembly is required to address the Limitations and Conditions in Section 4.0 of the Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2 [Ref. 3].
These conditions limit the amount of fiber reaching the fuel to 15 grams per fuel assembly for a hot leg break.
The grams of fiber per fuel assembly is calculated using Equation 1. This equation accounts for the only fiber debris source term at the strainer being latent debris
[Refs. 12 and 17].
__L=M*F*T*CF*B FA N
(Eq. 1)
Where:
g/F A grams of fiber per fuel assembly M
mass oflatent debris, 150 lbm [Refs. 12 and 17]
F fraction of latent debris that is fiber, 0.15 [Section 3.5.2.3 of Ref. 8]
N number of fuel assemblies, 193 assemblies [Ref. 7]
Calculation 2014-04466 Revision 1 Attachment A T
transport :fraction to strainer CF conversion from lbm to grams, 453.6 grams I lbm B
strainer fiber bypass fraction Equation I is simplified to Equation 2 by inserting known values.
__g__= 150*0.15*453.6 *T*B= 52.SS*T*B FA 193 Page A2 of Al 7 (Eq. 2)
It should be noted that the use of 150 lbm of latent debris is conservative relative to the amounts measured in containment as it exceeds the maximum measured amount by more than 20% [Refs. 12 and 17].
2.1 Clean Plant Criteria On December 22, 2011, a letter containing a simple set of resolution criteria (clean plant criteria) to address GSI-191 PWR sump performance for low fiber plants was issued by NEI [Ref. 1]. The NRC responded to these criteria in a letter dated May 2, 2012 [Ref. 2]. In the response, the NRC clarified the Staff's understanding of the criteria and concluded that "... the criteria, as clarified, provide an acceptable method of closing GSI-191 for operating PWRs."
The clean plant criteria, as applied to in-vessel effects, utilize a fiber bypass :fraction of 45% and a debris transport fraction of 75% [Ref. 1]. These values are acceptable to the NRC as demonstrated in the following excerpts :from Reference 2.
The highest bypass percentage observed by the staff for a fiber only test conducted for a low fiber plant with a typical complex geometry strainer under relatively conservative conditions is approximately 40%... the staff considers a bypass fraction of 45% to be conservative for most typical perforated plate strainer installations where flow patterns do not result in fragmentation of debris.
The staff concluded that an assumption of 7 5% transport to the strainer, as used in NEI's calculation, to be reasonable based on the following:
- 1. Inactive volumes: Plants may take credit for debris transport to inactive volumes. NRC staff guidance is that this value be limited to 15% regardless of the actual total inactive volume available for a specific plant. The 15%
limit is intended to account for delayed washdown of some debris which may not reach the holdup area before it is filled.
- 2. Fine debris capture: NUREGICR-6808 noted that there are several methods for fine debris capture. These are inertial impaction, diffusiophoresis, diffusion, settling, and spray washout. For latent debris it is unlikely that inertial impaction, diffusiophoresis, or diffusion would have a significant effect on debris capture. Settling and spray washout are likely to contribute
Calculation 2014-04466 Revision 1 Attachment A Page A3 of Al 7 to capture of latent debris. Capture by these mechanisms has been evaluated as likely for latent debris, but the effectiveness of the mechanisms has not been demonstrated and is plant specific. It is likely that some latent debris at all plants would be captured by these mechanisms.
- 3. Fine debris retention: NUREG/CR-6808 concluded that condensation drainage would leave a majority of fine debris in place, surfaces directly sprayed by containment sprays would have a majority of the fine debris removed, and that the retention of fine debris on surfaces experiencing spray drainage is uncertain.
The NRC then provided further justification for a 75% transport fraction [Ref. 2].
The staff concluded that the use of a lower [transport fraction] (e.g., 75%
transport fraction instead of at least 85% based on the SE to NEI-04-07) to calculate in-vessel limits for a clean plant is bolstered by the following unquantified conservatisms: I) some debris will not transport due to inactive holdup volumes and surface deposition, 2) in-vessel debris limits are determined using conservative test methodology, 3) in-vessel debris limits are determined at limiting values of flow and particulate to fiber ratio, 4) internal currents within the reactor vessel will likely result in nonuniform deposition of debris which is associated with reduced head loss, 5) most plants assume I 5%
of latent debris is fiber, based on an industry upper bound, but most low fiber plants have reported a significantly lower fraction of fiber in latent debris samples.
Based on the clean plant criteria values for debris transport fraction to the strainer (T) and strainer fiber bypass fraction (B), the following Byron I Braidwood specific in-vessel debris load is computed using Equation 2:
L = 52.88* T* B = 52.88* 0.75*0.45=17.8 g/FA FA This value exceeds the 15 grams per fuel assembly acceptance criterion. Therefore, the clean plant criteria cannot be used without modification. In order to use these criteria, a more appropriate fiber bypass fraction is determined based on the conditions expected for Byron/Braidwood.
2.2 Design Basis Fiber Bypass As discussed in Section 1.0, the NRC had concerns with the Byron/Braidwood plant specific fiber bypass testing. Therefore, the design basis is based on fiber bypass testing perfonned by CCI for other CCI strainers with the same size perforations
[2.1 mm or 1112 (0.083) inch per Refs. 21 and 22]. This approach is acceptable per Limitation 11 in Section 4.0 of the SER for WCAP-16793-NP, Revision 2 [Ref. 3],
which states the following:
Calculation 2014-04466 Revision 1 Attachment A Page A4 of Al 7 Licensees may determine the quantity of debris that passes through their strainers by... relying on strainer bypass values developed through strainer bypass testing of the same vendor and same perforation size, prorated to the licensee's plant specific strainer area; approach velocity; debris types, and debris quantities...
2.2.1 Industry Fiber Bypass Comparison A review of U.S. PWRs that installed CCI strainers was performed to determine an appropriate strainer bypass fraction for Byron/Braidwood. A summary of some of the pertinent information is provided below.
Salem [Refs. 4 and 5]: Strainers have the same perforation size. In 2006 (Bypass Test 9b) and 2008 (Bypass Test 3), CCI performed fiber bypass tests using only latent debris for Salem. These latent debris only tests are representative of some of the post-LOCA conditions expected at Byron and Braidwood (see summary in Table 2.1).
Palo Verde [Ref. 6]: Strainers have the same perforation size. Fiber bypass tests for Palo Verde, a low fiber plant, closely match limiting Byron I Braidwood conditions (see summary in Table 2.1 ).
D. C. Cook: Fiber bypass of 1.2% was measured and an assumed value of 5%
was used by Cook [Table 3n-1 in Attachment 4 to Ref. 10]. Additional details on bypass testing are not publicly available.
Oconee: Oconee credits the testing and results of Salem Nuclear Station for strainer bypass data [Item 13 in Enclosure to Ref. 9].
Calvert Cliffs: Strainers have a different perforation size [1/16 inch per Response to Issue 3jl in Attachment 1 to Ref. 11].
ANO 1 & 2: Strainers have a different perforation size [1/16 inch per Section A12 of Attachment 1 and Section B18 of Attachment 2 to Ref. 18].
R. E. Ginna: Strainer has a different perforation size [1116 inch per Section 3f.1.3 of Attachment 1 to Ref. 19].
Beaver Valley 1: Strainer has a different perforation size [1/16 inch per Section 3.j.1 of Attachment 1 to Ref. 20].
Based on the similarities in strainer design, debris load, and penetration velocity between Byron, Braidwood, Salem and Palo Verde, bypass testing data for Salem and Palo Verde are used to determine a conservative bypass fraction for Byron and Braidwood. Table 2.1 provides a comparison of strainer characteristics for Salem, Palo Verde, and Byron I Braidwood.
Calculation 2014-04466 Revision 1 Attachment A T bl 21 C a e. :
omparison o f S tram er Ch aracterist1cs Parameter Salem Palo Verde
[Refs. 4 and 5]
[Ref. 6]
Strainer 1112 inch 1/12 inch Perforation Size (0.083 inch)
Penetration Test 9b: 0.0041 ft/s 0.0094 ft/s Velocity (a)
Test 3: 0.0047 ft/s Effective Strainer Test 9b: 4,845 ft2 2,742 ft2 Area Test 3: 4,156 ff Flow Rate Test 9b: 9,000 gpm Max. flow rate through Single Test 3: 8,850 gpm of 11,600 gpm Strainer Train Latent fiber only Nukon fiber (c)
Debris Type and (both tests used 12.5 ft3 (Quantity not Quantity of Nukon fiber) available)
Theoretical Bed Test 9b: 0.031 in Not available Thickness (e)
Test 3: 0.036 in Page AS of Al 7 Byron I Braidwood 1112 inch
[2.1 mm; Refs. 21 & 22]
0.0047 ft/s before CS switchover; 0.0094 ft/s after CS switchover 2 160 ff (b)
Max. before CS (t) switchover: 4,557 gpm Max. after CS (g) switchover: 9,115 gpm Latent fiber only
[9.375 ft3 (d)]
0.052 in a) Penetration velocity = maximum flow rate through single strainer I effective strainer area [Vpen (ft/s) = Q (gpm)*(l min/60 sec)*(l ft3/7.48 gal) I Aettective ff].
b) Installed area (3059.5 ft2) less the sacrificial area (900 ft2) [Ref. 23].
c) Nukon is the only fiber type referred to in Reference 6.
d) Latent fiber as-fabricated volume (ft3) = latent debris mass [150 Ihm, Ref. 17]
- latent fiber fraction [0.15; Refs. 8 and 17] I latent fiber as-fabricated density
[2.4 lbm/ft3; p. 52 of Ref. 8]
e) Theoretical bed thickness (in) latent fiber as-fabricated volume (ft3) I effective strainer area (ff) * (12 in/ft) t) Maximum strainer flow prior to CS switchover is taken from Case 4 7B of Reference 14 which maximizes the residual heat removal (RH) pump flow during recirculation. The RH pump flow equals the strainer flow for this case.
Case 4 7B models one RH pump as operating; i.e. there is only flow through one strainer.
g) Maximum strainer flow is taken from Case 7B of Reference 14 [ 4640 gpm containment spray (CS) flow + 4475 gpm RH flow] which maximizes sump flow during recirculation. Case 7B models a one RH and one CS pump as operating; i.e. there is only flow through one strainer.
Calculation 2014-04466 Revision 1 Attachment A 2.2.2 Staggered RH and CS Pump Switchover Page A6 of Al 7 At Byron and Braidwood, the RH pump suction switchover (referred to as RH switchover herein) from the RWST to the Containment Recirculation Sump (referred to as "sump" herein) begins once the L0-2 level is reached in the RWST while CS pump suction switchover from the RWST to the Containment Recirculation Sump begins once the L0-3 level is reached in the RWST [Ref. 14].
The staggered switchover results in a period of time where the total flow through the Emergency Core Cooling System (ECCS) strainers is not the maximum strainer flow (which occurs following CS switchover). Since fiber bypass is impacted by penetration velocity, it is reasonable to model different fiber bypass fractions during recirculation for the times before and after CS switchover.
To analyze fiber bypass during staggered switchover, the fraction of fiber in the containment sump pool that reaches the strainers between RH and CS switchover is required. The fiber removed from the sump pool is estimated based on the fiber bypass fraction and the assumption that the debris is uniformly distributed in the pool. A uniform distribution of fiber is appropriate for Byron and Braidwood since the only fibrous debris is latent. By modeling the debris as being uniformly distributed throughout the pool, the amount of fiber in the pool at any time after recirculation can be related to pool turnovers. This method conservatively models all fiber that bypasses the strainer as immediately returning to the sump pool (i.e. no debris is retained downstream of the strainer). The equations and method used to determine the transient fiber concentration in the pool are provided below.
The mass of fiber in the pool (m) initially (i=O) is equal to the total mass of fiber (m101). This results in an initial fiber fraction (fo) of 1.
mo= mrot f;
m;lmror:fo I
(Eq. 3)
(Eq. 4)
The concentration of fiber in the pool (C) is based on the mass of fiber in the pool (m) and the pool volume (Vpoo1). Since the CS pumps continue to drawdown the RWST and supply the spray header in containment following RH switchover, the pool volume increases between RH and CS switchover. For this calculation, the average pool volume during this time is used.
(Eq. 5)
The volume of water flowing through the strainer (Vs1r) during a given time step is computed using the strainer flow rate (Q) and time step duration from i to i+ 1 (~t).
Vstr,itoi~J =Q *(fH1-tJ (Eq. 6)
Calculation 2014-04466 Revision 1 Attachment A Page A7 of Al 7 The number of pool turnovers flowing through the strainer during a time step (nro) is computed by dividing Equation 6 by the pool volume.
nro,;+1-nro,; = Vs1r,itoi+1 I Vpoot (Eq. 7a)
Vstr.i to;+ 1 = (nro,;+ 1 - nro,J
- Vpool (Eq. 7b)
The fiber quantity retained on the strainer (removed from the pool) (mr) in a given time step is computed using the fiber concentration, the water volume flowing through the strainer, and the fiber bypass fraction (fbypas5).
mr,; = C;
- Vstr,i to ;+1 * (1-fiypass)
(Eq. 8)
By substituting the definitions for fiber concentration (Eq. 4) and flow through the strainer (Eq. 7b) into Equation 8 and dividing by the total fiber mass, an equation for the fraction of fiber removed (fr) based on the fraction of total fiber in the pool (f), pool turnovers, and fiber bypass fraction is obtained.
mr,i I mtot = (m1 I VpooJ * [(nro,;+ J - nro,J
- VpooU * (1 - fiypass) I mtot fr.; = f; * (nro,;+ 1 - nro,J * (1 - fiypassJ (Eq. 9)
(Eq. 10)
The total mass of fiber in the pool for subsequent time steps (i ~ 1) is based on the fiber mass in the pool in the previous time step and the fiber removed during the previous time step.
m; = m;_J - mr,i-1 (Eq. 11)
Dividing by the total fiber mass results in an equation based on fiber fractions.
f; = /; fr.i-1 The cumulative amount of :fiber removed (%fiber,removed) is:
i
%fiber.removed = L fr,i i=O (Eq. 12)
(Eq. 13)
The transient fiber fraction in the pool as a function of pool turnovers is determined using Equations 4, 10, 12, and 13 in Attachment A.l and presented in Figure 2.1. A strainer bypass fraction of 15% (i.e. 85% of debris that transports to the strainer is captured) is used in the computation, consistent with the :findings in Section 2.2.5 for the time prior to CS switchover (see Figure 2.2). For the time prior to CS switchover, a bypass fraction of 15% is conservative as it greatly exceeds the expected fiber bypass based on bypass test data for other CCI strainers with a similar configuration to Byron/Braidwood.
Calculation 2014-04466 Revision 1 Attachment A 2.2.3 Pool Turnovers between RH and CS Switchover Page A8 of Al 7 To determine the maximum amount of fiber subject to the higher strainer velocities after CS switchover, the minimum amount of fiber retained on the strainer between RH and CS switchover is determined using Figure 2.1 and the number of pool turnovers between RH and CS switchover. The number of turnovers is determined as follows.
(Eq. 14)
Where:
nro number of pool turnovers between RH and CS switchover Q
recirculation flow rate between RH and CS switchover (for either 1 or 2 train operation)
Lit time between RH and CS switchover Vpool average pool volume between RH and CS switchover The number of turnovers between RH and CS switchover is determined based on the cases presented in the minimum and maximum flood level calculations
[Refs. 24 & 25, respectively] since these design basis documents contain all required information (modeled flow rates, switchover times, and pool volumes) and assess the limiting pool volumes. The minimum flood level calculation includes both 1 and 2 train operation cases, while the maximum flood level calculation includes only 2 train operation cases. Thus, the number of turnovers computed encompasses both 1 and 2 train operation.
Attachment A.2 computes the number of turnovers between RH and CS switchover for each case analyzed in the flood level calculations. Note, Reference 24 refers to ECCS switchover, which includes all ECCS pumps (CV, SI, RH), not just the RH pumps. The timing ofECCS switchover is the same as RH switchover since the RH pumps are part of the Emergency Core Cooling System. The discussion herein refers to RH switchover since the RH pumps are the only ECCS pumps to take suction from the sump following switchover.
The computed number of turnovers for the maximum flood scenarios is based on ATD-0111 [Ref. 25]. However, the maximum flood level analysis models one RH suction valve from the RWST as failing to close at RH switchover which results in an RH pump assisting in the drawdown of the RWST (following RH switchover) and direct gravity feed from the RWST to the sump, both of which reduce the time between RH and CS switchover. Furthermore, the maximum flood level analysis predicts the sump water level assuming that the entire RWST empties, which increases the time between RH and CS switchover. To determine a reasonable number of turnovers, the results from Reference 25 are adjusted in Attachment A.2
Calculation 2014-04466 Revision 1 Attachment A Page A9 of Al 7 as described below to reflect more realistic conditions and to determine the sump volume at CS switchover initiation. Three main adjustments are made.
- 1) RWST Outflow: The turnovers for the maximum flood scenarios are computed in Attachment A.2 assuming the RWST to RH pump isolation valves both close properly, which results in less RWST outflow following the completion of RH switchover than modeled in Reference 25. This adjustment also results in two RH pumps drawing from the sump following RH switchover. The revised RWST outflow consists of two trains CS, CV, and SI flow and is modeled as continuing until the point of CS switchover initiation [Design Input 4.3 of Ref. 25]. Since the time between RH switchover completion and CS switchover initiation is less than 412 seconds, SI switchover is not complete prior to CS switchover initiation. Thus, the RWST outflow is modeled as constant between RH switchover completion and CS switchover initiation.
- 2) Sump Volume at CS Switchover: To determine the sump volume at CS switchover, first the RWST volume at CS switchover is determined using the RWST level at CS switchover initiation (L0-3, 12%) and corresponding RWST volume at this point from Reference 26. Once the RWST volume at CS switchover initiation and RH switchover completion (from Ref. 25) are known, the total RWST volume injected between RH switchover completion and CS switchover initiation is computed along with the time to inject this volume using the flow rate from Adjustment 1 above. The sump volume at CS switchover initiation is then computed by subtracting the volume of water remaining in the RWST at CS switchover initiation from the computed sump volume in Reference 25 at a time approximately equal to the time of CS switchover initiation (~1560 seconds). The sump volume at this time in Reference 25 is based on the entire RWST having been injected into the sump (i.e. empty RWST).
- 3) Sump Flow Rate: The flow rate out of the sump is based on two train operation (i.e. two RH pumps) to be consistent with Adjustment 1 above. For two train operation prior to CS switchover initiation, one RH pump draws from each ECCS sump strainer.
The number of turnovers between RH and CS switchover ranges from 0.26 (for maximum flood scenarios) to 1.0 (for minimum flood scenarios), as shown in Attachment A.2. Given the conservatisms already being used in this assessment (e.g. design latent debris mass and latent fiber fraction) as well as the conservatisms employed in the flood level calculations, the median value of 0.63 turnovers between RH and CS switchover is used. This is consistent with the NRC guidance to treat GSI-191 holistically [Ref. 13]. It should also be noted that the use of 15 grams of fiber per fuel assembly as an in-vessel fiber acceptance criterion is conservative, as acknowledged by the NRC in the SER for WCAP-16793 [p. 36 of Ref. 3], which states:
Calculation 2014-04466 Revision 1 Attachment A PageA10ofA17 The NRC staff finds that a 15 gram fiber limit is a conservative value for all plant types included in the WCAP...
Finally, the bypass fractions chosen for design in Section 2.2.5 below are also conservative and include significant margin over the expected values.
2.2.4 Fiber Retained on Strainer Prior to CS Switchover Figure 2.1 shows that after 0.63 turnovers a minimum of 42% of the fibrous debris has been removed from the active pool. Note, the fraction of fiber on the screen prior to CS switchover would be slightly higher ifthe debris transported during pool fill-up were accounted for since some debris reaches the strainer prior to recirculation. Both recirculation sump pits would be filled during pool fill-up regardless of whether one or two ECCS/CS trains are in operation.
100%
90%
~
~
80%
s..
~ 70%
=
e'iS s..
60%
ff.)
=
0 50%
s..
40%
~
.c...
~ 30%
e'iS 20%
~
10%
0%
0 0.5 1.5 2
2.5 3
Sump Pool Turnovers Figure 2.1: Fiber Capture on Strainer To be conservative, only 40% fiber capture prior to CS switchover is assumed for this analysis. This is conservative as slightly more fiber is subjected to a higher bypass. The plant flow rate, screen penetration velocity and fraction of debris reaching the strainer are provided in Table 2.2 for the time before and after CS recirculation switchover.
Calculation 2014-04466 Revision 1 T bl 2 2 B a e. : iyron Before CS Switchover After CS Switchover Attachment A
/B "d
ra1 woo dP arameters Byron/Braidwood Plant Flow Rate<a>
4,557 gpm 9,115 gpm a) See Table 2.1 for basis.
2.2.5 Overall Fiber Bypass Fraction Page All of Al 7 Penetration Fraction of Debris Velocity(a)
Reachin2 Strainer 0.0047 ft/s 40%
0.0094 ft/s 60%
Once the fraction of debris reaching the strainer prior to CS recirculation switchover is determined, an overall fiber bypass fraction (B) can be calculated.
B = XEees
- BEees + Xes *Bes = 0.40
- BEees + 0.60 *Bes (Eq. 15)
Where:
XEccs fraction of debris reaching strainer before CS switchover Xcs fraction of debris reaching strainer after CS switchover BEccs fiber bypass fraction for debris reaching strainer before CS switchover Bes fiber bypass fraction for debris reaching strainer after CS switchover To determine the appropriate fiber bypass fractions for before and after CS switchover, data from Salem and Palo Verde is utilized.
Table 2.3 and Figure 2.2 present the Salem and Palo Verde fiber bypass test data as bypass percentage versus penetration velocity. The Salem fiber bypass data is computed based on the information presented in References 4 and 5, as explained below. The Palo Verde fiber bypass data (without bump-up) is taken from p. 3-155 of Reference 6.
The fiber bypass for Salem Test 9b in 2006 is 0.25 Ihm per 1000 ft2 [Figure 3f.4.2.2.2-2 of Attachment 1 to Ref. 4]. Given the tested plant strainer area of 4845 ft2 [Section 3f.4.1.3.2 of Attachment 1 to Ref. 4], this corresponds to 1.21 lbm
[=0.25*4845/1000] of fiber bypass. To compute the total fiber added to the test loop for this test, the scale factor (180.8) and added fiber mass (0.0623 kg) are used
[Section 3f.4.1.3.4 of Attachment 1 to Ref. 4]. The total fiber added to the test loop for this test was equivalent to 24.83 Ihm in the plant [=180.8*0.0623*2.2046].
- Thus, the measured fiber bypass percentage for this test is 4.87%
[=1.21124.83* 100].
The reason 12.5 ft3 of latent fiber is not equal to 30 Ihm for Salem Test 9b in 2006 is that the measured Nukon density (1.94 lbm/ft3) was used for the conversion from as-fabricated volume to mass in this test series as explained on p. 10 of to Reference 5. The measured density is less than the typically used
Calculation 2014-04466 Revision 1 Attachment A Page A12 of Al 7 density of 2.4 lbm/ft3 [p. 52 of Ref. 8]. It is also recognized that 12.5 ft3 of 1.94 lbm/ft3 fiber yields 24.25 Ihm; the difference between this value and the computed value above (24.83 lbm) is presumably due to truncation errors in the computation (original density was probably in kg/m3 and then converted to lbm/ft3).
The fiber bypass for Salem Test 3 in 2008 is 0.68 Ihm per 1000 ft2 [p. 10 of to Ref. 5]. Given the tested plant strainer area of 4156 ft2 [Sections 3f.4.l.5.4 and 3f.4.1.6.2 of Attachment 1 to Ref. 4], this corresponds to 2.83 lbm
[=0.68*4156/1000] of fiber bypass. The total fiber added to the test loop for this test was equivalent to 30 lbm in the plant [p. 141 of Attachment 1 to Ref. 4]. Thus, the measured fiber bypass percentage for this test is 9.43% [=2.83/30*100].
The amount of bypassed fibers for Salem and Palo Verde is increased by 9% to account for NRC concerns with the fiber bypass capture screen used in the CCI fiber bypass tests [Attachment 1 of Ref. 5]. Specifically, the NRC was concerned that some fiber that bypassed the strainer would then pass through the fiber capture screen due to the capture screen hole size of 0.31 mm [0.012 inch in Ref 6]. To account for potential capture screen bypass during the tests, an increase factor was developed by Salem and accepted by the NRC [Refs. 27 and 28].
T bl 2 3 S I a e.. a em an dP I V d F'b B
ao er e 1 er iypass T tD t es aa Test Data Penetration Fiber Bypass Fiber Bypass Velocity with Bump-Up (ft/s)
(%)
(%)
Salem (2006 Test 9b) 0.0041 4.87 5.3 Salem (2008 Test 3) 0.0047 9.43 10.3 Palo Verde (Test 02) 0.0094 8.1 8.8 Palo Verde (Test 03) 0.0094 12.3 13.4 Two points are added to Figure 2.2 to represent the bypass fractions used for Byron and Braidwood before and after CS recirculation switchover. Note that these points are based on the maximum penetration velocities during recirculation before and after CS switchover. This is conservative, as most operating scenarios will experience lower penetration velocities. As noted in Notes '-f and 'g' to Table 2.1, these penetration velocities are based on single train operation, even though two train operation would be expected [Ref. 15] and two train operation would have lower strainer flow rates/penetration velocities. Two train operation would result in higher flow rates and pressure drop through shared portions of the system (e.g. RCS legs), resulting in less flow rate per pump (and hence per sump strainer) than for single train operation. This is consistent with Section 6.1.5.1 of Reference 14 which describes the system line-up (i.e. single train) for maximum sump flow.
Before CS recirculation switchover a fiber bypass fraction of 15% is used. This conservatively bounds the bypass data at similar penetration velocities with approximately 50% margin.
Calculation 2014-04466 Revision 1 Attachment A Page Al3 of Al 7 The maximum penetration velocity after CS recirculation switchover is equal to that used in the Palo Verde fiber bypass tests. To be conservative, a bypass fraction of 40% is used for fiber that reaches the strainer after CS recirculation switchover.
This value is consistent with the highest bypass percentage observed by the Staff for a fiber only test for a low fiber plant with a complex geometry strainer [Ref. 2]. As can be seen in Figure 2.2, this value is very conservative relative to the Salem and Palo Verde data.
50%
I 45%
I NRC Clean Plant Bypass Fraction I
40%
~
35%
!.... 30%
I i
- Salem Fiber Bypass Data
- Palo Verde Fiber Bypass Data T
IA Values Used for BYR/BRW
('I 25%
- g.
.... =
i..
20%
41
Penetration Velocity Before CS Switchover
- Penetration Velocity After CS Switchover I
.c I
~ 15%
10%
5%
.l t
I -
T T
I I
I I
0%
I 0
0.002 0.004 0.006 0.008 0.01 Penetration Velocity [ft/s]
Figure 2.2: Fiber Bypass versus Penetration Velocity Based on the data in Figure 2.2, the following overall bypass fraction is calculated for Byron and Braidwood using Equation 15.
B = XEccs
- BEccs +Xcs *Bes= 0.40
- 0.15 + 0.60
- 0.40 = 0.300 = 30.0%
2.3 In-Vessel Fiber Loading The quantity of fiber per fuel assembly is calculated below using Equation 2 with a bypass fraction (B) of 30%. The transport fraction to the strainer (T) is maintained at the clean plant criteria value (75%).
__L = 52.88
- T
- B = 52.88
- 0.75*0.30=11.9 g/ FA FA This value is less than the 15 grams per fuel assembly acceptance criterion.
Calculation 2014-04466 Revision 1 3.0 Conclusions Attachment A Page A14 of Al 7 This attachment determines that an appropriate fiber bypass fraction to use for the CCI strainers at Byron and Braidwood is 30%. This value is based on both testing of other CCI strainers as well as a recognized conservative fiber bypass fraction through complex, perforated plate strainers.
Using the fiber bypass value above, the in-vessel fiber loading is 11.9 grams per fuel assembly.
The in-vessel fiber loading is computed using the clean plant criteria, but with the more appropriate fiber bypass fraction determined herein. This is the only difference between the approach for Byron/Braidwood and the clean plant criteria.
The reduced fiber bypass fraction is justified due to the lower penetration velocity before CS recirculation switchover and by adding significant margin to available industry fiber bypass data.
4.0 References
- 1.
Letter from J. Butler (NEI) to S. Bailey (NRC) dated December 22, 2011, "Transmittal of GSI-191 Resolution Criteria for "Low Fiber" Plants." ADAMS Accession No. MLl 13570229.
- 2.
Letter from W. Ruland (NRC) to J. Butler (NEI) dated May 2, 2012, "NRC Review of Nuclear Energy Institute Clean Plant Acceptance Criteria for Emergency Core Cooling Systems." ADAMS Accession No. ML120730181.
- 3.
Safety Evaluation by the Office of Nuclear Reactor Regulation to WCAP-16793-NP, Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," October 2011 (ADAMS Accession No. ML12084Al54). Transmitted via letter from Sher Bahadur (NRC) to Anthony Nowinowski (PWR Owners Group), on April 8, 2013, (ADAMS Accession No. ML13084A152)).
- 4.
PSEG Letter No. LR-N12-0124 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Supplemental Response to Generic Letter 2004-02, Including Attachment 1, "Salem Nuclear Generating Station Units 1 and 2 Docket Nos. 50-272 and 50-311 Generic Letter 2004-02 Updated Supplemental Response for Salem," dated April 27, 2012. ADAMS Accession Nos. ML12129A389 & ML12129A390.
- 5.
PSEG Letter No. LR-N13-0091 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Responses to NRC Questions Regarding Salem Bypass Testing, dated April 22, 2013. ADAMS Accession No. ML13114A048.
- 6.
APS Letter No. 102-06805-DCMIRKR from John J. Cadogan (Palo Verde) to USNRC,
Subject:
Palo Verde Nuclear Generating Station (PVNGS) Units 1, 2, and 3 Docket Nos. STN 50-528, 50-529, and 50-530 Revision 2 to Supplemental
Calculation 2014-04466 Revision 1 Attachment A Page A15 of Al 7 Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors, dated December 18, 2013. ADAMS Accession No. ML13357A218.
- 7.
Byron/Braidwood UFSAR, Revision 15, Table 4.1-1.
- 8.
Safety Evaluation by the Office of Nuclear Reactor Regulation Related to NRC Generic Letter 2004-02, Nuclear Energy Institute Guidance Report (Proposed Document Number NEI 04-07), "Pressurized Water Reactor Sump Performance Evaluation Methodology." ADAMS Accession No. ML043280641.
- 9.
Duke Energy Letter No. ONS-2014-024 from Scott L. Batson (Oconee) to USNRC,
Subject:
Oconee Closure Option 1 Response for Generic Safety Issue (GSI)-191, "Assessment of Debris Accumulation on Pressurized-Water Reactor Sump Performance" in Resolution of Final Issues Related to Generic Letter (GL) 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated February 27, 2014. ADAMS Accession No. ML14065A040.
- 10.
AEP Letter No. AEP-NRC-2010-39 from Joel P. Gebbie (AEP) to USNRC,
Subject:
Updated Final Response to Nuclear Regulatory Commission Generic Letter 2004-02: Potential impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors and a June 2009 Request for Additional Information, dated May 26, 2010. ADAMS Accession No. ML101540527.
- 11.
Constellation Energy Nuclear Generation Group (James A. Spina I Calvert Cliffs)
Letter to the USNRC,
Subject:
Calvert Cliffs Nuclear Power Plant Unit Nos. 1 & 2; Docket Nos. 50-317 & 50-318, Supplemental Response to Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized Water Reactors," dated February 29, 2008. ADAMS Accession No. ML080640751.
- 12.
Exelon Letter No. RS-07-161 from Patrick R. Simpson (Exelon) to USNRC, "Supplemental Response to NRC Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated December 31, 2007. ADAMS Accession No. ML080280562.
- 13.
NRC Staff Memorandum from A. L. Bates to L. A. Reyes,
Subject:
Staff Requirements -
Briefing on Resolution of GSI-191, Assessment of Debris Accumulation on PWR Sump Performance, 1 :30 P.M., Wednesday, October 25, 2006, Commissioners' Conference Room, One White Flint North, Rockville, Maryland (Open to Public Attendance), dated November 16, 2006, M061025C.
ADAMS Accession No. ML063200471.
Calculation 2014-04466 Revision 1 Attachment A Page A16 of Al 7
- 14.
Calculation BYR06-029 I BRW-06-0016-M, Rev. S, "SI/RHR/CS/CV System Hydraulic Analysis in Support of GSI-191." Byron currently uses Rev. S, and Braidwood uses Revs.Sand SA. The information used herein is from Rev.Sand is not impacted by Rev. SA.
1 S.
Byron I Braidwood Procedures lS.1 lBEP ES-1.3, Rev. 206, "Transfer to Cold Leg Recirculation Unit 1."
lS.2 2BEP ES-1.3, Rev. 206, "Transfer to Cold Leg Recirculation Unit 2."
lS.3 lBwEP ES-1.3, Rev. 203, "Transfer to Cold Leg Recirculation Unit l."
lS.4 2BwEP ES-1.3, Rev. 203, "Transfer to Cold Leg Recirculation Unit 2."
- 16.
Exelon Letter RS-lS-283 from David M. Gullott (Exelon) to USNRC,
Subject:
Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSI)-191), dated October 30, 201S, Including Attachment "Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 0, Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-1 6793-NP." ADAMS Accession No. ML1S303A408.
- 17.
Calculation No. BRW-OS-OOS9-M I BYROS-041, Rev. 2, "GSI-191 Post-LOCA Debris Generation."
- 18.
Entergy Letter No. OCAN090901 from Kevin T. Walsh (ANO) to USNRC,
Subject:
Generic Letter 2004-02 Final Supplemental Response Request for Additional Information Arkansas Nuclear One - Units 1 and 2 Docket Nos. S0-313 and S0-368 License Nos. DPR-Sl and NPF-6, dated September 24, 2009. ADAMS Accession No. ML092720684.
- 19.
Constellation Energy Nuclear Generation Group (John Carlin IR. E. Ginna) Letter to the USNRC,
Subject:
Supplementary Response to Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated February 29, 2008. ADAMS Accession No. ML080710041.
- 20.
FirstEnergy Nuclear Operating Company (FENOC) Letter No. L-09-1S2 from Peter P. Sena III (Beaver Valley) to USNRC,
Subject:
Supplemental Response to Generic Letter 2004-02 (TAC Nos. MC466S and MC4666), dated June 30, 2009. ADAMS Accession No. ML091830390.
- 21.
CCI Drawing 103.132.173.SOO, Revision 0, "Side Wall Long Version Seitenwand Lange Version Type 4."
- 22.
CCI Drawing 103.132.174.SOO, Revision 0, "Pocket Long Version Tasche Lange Version."
- 23.
CCI Report 3 SA-096.018, Revisions 8 (Byron) and 9 (Braidwood), "Head Loss Calculation." The information used herein is the same in Revisions 8 and 9.
Calculation 2014-04466 Revision 1 Attachment A Page A 1 7 of A 1 7
- 24.
Calculation SI-90-01, Revision 11, "Minimum Containment Flood Level."
- 25.
Calculation ATD-0111, Revision 15, "Maximum Containment Flood Level."
- 26.
Calculation SITH-1, Revision 8, "Refueling Water Storage Tank (RWST) Level Setpoints."
- 27.
NRC Letter (John G. Lamb) to PSEG (Thomas Joyce),
Subject:
Salem Nuclear Generating Station, Units 1 and 2 - Close-out of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors" (TAC Nos. MC4712 and MC4713),
dated April 30, 2014. ADAMS Accession No. ML14113A202.
- 28.
U.S. Nuclear Regulatory Commission Staff Review of the Documentation Provided by PSEG Nuclear, LLC, for Salem Nuclear Generating Station, Units 1 and 2, Concerning Resolution of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors." ADAMS Accession No. ML14113A221.
The following Byron/Braidwood drawing and calculation References were verified as current in PASSPORT on 3/14/2016: 7, 14, 15, 17, 24, 25, and 26.
5.0 Attachments (to Attachment A of2014-04466)
Attachment A.1: Transient Fiber Fraction in Sump Pool (12 pages)
Attachment A.2: Pool Turnovers Between ECCS and CS Switchover (12 pages)
Calculation 2014-04466 Revision 1 A
8 1 Strainer Bypass Fraction, fbypass 2
Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 = 1.0 3
nro f; =f1..1 *f*L* (i?:.1) 4 0.00 1.00 5
0.01 0.99 6
0.02 0.98 7
0.03 0.97 8
0.04 0.97 9
0.05 0.96 10 0.06 0.95 11 0.07 0.94 12 0.08 0.93 13 0.09 0.93 14 0.10 0.92 15 0.11 0.91 16 0.12 0.90 17 0.13 0.89 18 0.14 0.89 19 0.15 0.88 20 0.16 0.87 21 0.17 0.86 22 0.18 0.86 23 0.19 0.85 24 0.20 0.84 25 0.21 0.84 26 0.22 0.83 27 0.23 0.82 28 0.24 0.81 29 0.25 0.81 30 0.26 0.80 31 0.27 0.79 32 0.28 0.79 33 0.29 0.78 34 0.30 0.77 35 0.31 0.77 36 0.32 0.76 37 0.33 0.75 38 0.34 0.75 39 0.35 0.74 40 0.36 0.74 Attachment A.1 Page A. 1-1 of A. 1-12 c
D 0.15 Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,1 = f1 * (n ro,1+1
- n ro,1) * (1*f bypass)
% f/ber,removed = If r,I from i=O to i 0.0085 0.9%
0.0084 1.7%
0.0084 2.5%
0.0083 3.4%
0.0082 4.2%
0.0081 5.0%
0.0081 5.8%
0.0080 6.6%
0.0079 7.4%
0.0079 8.2%
0.0078 9.0%
0.0077 9.7%
0.0077 10.5%
0.0076 11.3%
0.0075 12.0%
0.0075 12.8%
0.0074 13.5%
0.0074 14.2%
0.0073 15.0%
0.0072 15.7%
0.0072 16.4%
0.0071 17.1%
0.0070 17.8%
0.0070 18.5%
0.0069 19.2%
0.0069 19.9%
0.0068 20.6%
0.0068 21.3%
0.0067 21.9%
0.0066 22.6%
0.0066 23.3%
0.0065 23.9%
0.0065 24.5%
0.0064 25.2%
0.0064 25.8%
0.0063 26.5%
0.0063 27.1%
Att A.1
Calculation 2014-04466 Revision 1 A
8 Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f1 =f1..1 *f.u {i~1) 41 0.37 0.73 42 0.38 0.72 43 0.39 0.72 44 0.40 0.71 45 0.41 0.70 46 0.42 0.70 47 0.43 0.69 48 0.44 0.69 49 0.45 0.68 50 0.46 0.68 51 0.47 0.67 52 0.48 0.66 53 0.49 0.66 54 0.50 0.65 55 0.51 0.65 56 0.52 0.64 57 0.53 0.64 58 0.54 0.63 59 0.55 0.63 60 0.56 0.62 61 0.57 0.61 62 0.58 0.61 63 0.59 0.60 64 0.60 0.60 65 0.61 0.59 66 0.62 0.59 67 0.63 0.58 68 0.64 0.58 69 0.65 0.57 70 0.66 0.57 71 0.67 0.56 72 0.68 0.56 73 0.69 0.55 74 0.70 0.55 75 0.71 0.55 76 0.72 0.54 77 0.73 0.54 78 0.74 0.53 Attachment A.1 Page A. 1-2 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed From Pool (Eq.13)
Removed from Pool (Eq. 10)
% fiber,removed = If r,i f r,i : f; * (n TO,i+1
- n TO,;) * (1-f bypass) from i=O to i 0.0062 27.7%
0.0061 28.3%
0.0061 28.9%
0.0060 29.5%
0.0060 30.1%
0.0059 30.7%
0.0059 31.3%
0.0058 31.9%
0.0058 32.5%
0.0057 33.0%
0.0057 33.6%
0.0056 34.2%
0.0056 34.7%
0.0055 35.3%
0.0055 35.8%
0.0055 36.4%
0.0054 36.9%
0.0054 37.5%
0.0053 38.0%
0.0053 38.5%
0.0052 39.0%
0.0052 39.6%
0.0051 40.1%
0.0051 40.6%
0.0050 41.1%
0.0050 41.6%
0.0050 42.1%
0.0049 42.6%
0.0049 43.1%
0.0048 43.6%
0.0048 44.0%
0.0048 44.5%
0.0047 45.0%
0.0047 45.5%
0.0046 45.9%
0.0046 46.4%
0.0046 46.8%
0.0045 47.3%
Att A.1
Calculation 2014-04466 Revision 1 A
8 Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f1 = f 1.1 - f.** (i ~ 1) 79 0.75 0.53 80 0.76 0.52 81 0.77 0.52 82 0.78 0.51 83 0.79 0.51 84 0.80 0.51 85 0.81 0.50 86 0.82 0.50 87 0.83 0.49 88 0.84 0.49 89 0.85 0.48 90 0.86 0.48 91 0.87 0.48 92 0.88 0.47 93 0.89 0.47 94 0.90 0.46 95 0.91 0.46 96 0.92 0.46 97 0.93 0.45 98 0.94 0.45 99 0.95 0.44 100 0.96 0.44 101 0.97 0.44 102 0.98 0.43 103 0.99 0.43 104 1.00 0.43 105 1.01 0.42 106 1.02 0.42 107 1.03 0.42 108 1.04 0.41 109 1.05 0.41 110 1.06 0.40 111 1.07 0.40 112 1.08 0.40 113 1.09 0.39 114 1.10 0.39 115 1.11 0.39 116 1.12 0.38 Attachment A.1 Page A.1-3 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,i : f1 * (n T0,1+1 "n TO,/) * (1-f bypass)
% fiber,removad = I:f r,/
from i=O to i 0.0045 47.7%
0.0044 48.2%
0.0044 48.6%
0.0044 49.1%
0.0043 49.5%
0.0043 49.9%
0.0043 50.3%
0.0042 50.8%
0.0042 51.2%
0.0041 51.6%
0.0041 52.0%
0.0041 52.4%
0.0040 52.8%
0.0040 53.2%
0.0040 53.6%
0.0039 54.0%
0.0039 54.4%
0.0039 54.8%
0.0038 55.2%
0.0038 55.6%
0.0038 55.9%
0.0037 56.3%
0.0037 56.7%
0.0037 57.0%
0.0037 57.4%
0.0036 57.8%
0.0036 58.1%
0.0036 58.5%
0.0035 58.8%
0.0035 59.2%
0.0035 59.5%
0.0034 59.9%
0.0034 60.2%
0.0034 60.6%
0.0034 60.9%
0.0033 61.2%
0.0033 61.6%
0.0033 61.9%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f, = fu
- frL* (i~ 1) 117 1.13 0.38 118 1.14 0.38 119 1.15 0.37 120 1.16 0.37 121 1.17 0.37 122 1.18 0.37 123 1.19 0.36 124 1.20 0.36 125 1.21 0.36 126 1.22 0.35 127 1.23 0.35 128 1.24 0.35 129 1.25 0.34 130 1.26 0.34 131 1.27 0.34 132 1.28 0.34 133 1.29 0.33 134 1.30 0.33 135 1.31 0.33 136 1.32 0.32 137 1.33 0.32 138 1.34 0.32 139 1.35 0.32 140 1.36 0.31 141 1.37 0.31 142 1.38 0.31 143 1.39 0.31 144 1.40 0.30 145 1.41 0.30 146 1.42 0.30 147 1.43 0.30 148 1.44 0.29 149 1.45 0.29 150 1.46 0.29 151 1.47 0.29 152 1.48 0.28 153 1.49 0.28 154 1.50 0.28 Attachment A.1 Page A.1-4 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed From Pool (Eq. 13)
Removed from Pool (Eq. 10)
% fiber.removed= If r,i f r,i : f; * (n TO,i+1
- n TO,;) * (1*f bypess) from i=O to i 0.0032 62.2%
0.0032 62.5%
0.0032 62.9%
0.0032 63.2%
0.0031 63.5%
0.0031 63.8%
0.0031 64.1%
0.0031 64.4%
0.0030 64.7%
0.0030 65.0%
0.0030 65.3%
0.0029 65.6%
0.0029 65.9%
0.0029 66.2%
0.0029 66.5%
0.0029 66.8%
0.0028 67.0%
0.0028 67.3%
0.0028 67.6%
0.0028 67.9%
0.0027 68.1%
0.0027 68.4%
0.0027 68.7%
0.0027 68.9%
0.0026 69.2%
0.0026 69.5%
0.0026 69.7%
0.0026 70.0%
0.0026 70.2%
0.0025 70.5%
0.0025 70.7%
0.0025 71.0%
0.0025 71.2%
0.0024 71.5%
0.0024 71.7%
0.0024 72.0%
0.0024 72.2%
0.0047 72.7%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro
- f. =f1.1.f_. (i~1) 155 1.52 0.27 156 1.54 0.27 157 1.56 0.26 158 1.58 0.26 159 1.60 0.26 160 1.62 0.25 161 1.64 0.25 162 1.66 0.24 163 1.68 0.24 164 1.70 0.23 165 1.72 0.23 166 1.74 0.23 167 1.76 0.22 168 1.78 0.22 169 1.80 0.21 170 1.82 0.21 171 1.84 0.21 172 1.86 0.20 173 1.88 0.20 174 1.90 0.20 175 1.92 0.19 176 1.94 0.19 177 1.96 0.19 178 1.98 0.18 179 2.00 0.18 180 2.02 0.18 181 2.04 0.17 182 2.06 0.17 183 2.08 0.17 184 2.10 0.17 185 2.12 0.16 186 2.14 0.16 187 2.16 0.16 188 2.18 0.16 189 2.20 0.15 190 2.22 0.15 191 2.24 0.15 192 2.26 0.14 Attachment A.1 Page A.1-5 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq.13) f r,I = f1 * (n T0,1+1 "n TO,I) * (1*f bypass)
% fiber.removed=,Ef r,I from i=O to i 0.0046 73.1%
0.0046 73.6%
0.0045 74.1%
0.0044 74.5%
0.0043 74.9%
0.0043 75.4%
0.0042 75.8%
0.0041 76.2%
0.0040 76.6%
0.0040 77.0%
0.0039 77.4%
0.0038 77.8%
0.0038 78.1%
0.0037 78.5%
0.0037 78.9%
0.0036 79.2%
0.0035 79.6%
0.0035 79.9%
0.0034 80.3%
0.0034 80.6%
0.0033 80.9%
0.0032 81.3%
0.0032 81.6%
0.0031 81.9%
0.0031 82.2%
0.0030 82.5%
0.0030 82.8%
0.0029 83.1%
0.0029 83.4%
0.0028 83.7%
0.0028 83.9%
0.0027 84.2%
0.0027 84.5%
0.0026 84.7%
0.0026 85.0%
0.0025 85.3%
0.0025 85.5%
0.0025 85.8%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f/ = fi..1 "f.L4 (i?.1) 193 2.28 0.14 194 2.30 0.14 195 2.32 0.14 196 2.34 0.14 197 2.36 0.13 198 2.38 0.13 199 2.40 0.13 200 2.42 0.13 201 2.44 0.12 202 2.46 0.12 203 2.48 0.12 204 2.50 0.12 205 2.52 0.12 206 2.54 0.11 207 2.56 0.11 208 2.58 0.11 209 2.60 0.11 210 2.62 0.11 211 2.64 0.10 212 2.66 0.10 213 2.68 0.10 214 2.70 0.10 215 2.72 0.10 216 2.74 0.10 217 2.76 0.09 218 2.78 0.09 219 2.80 0.09 220 2.82 0.09 221 2.84 0.09 222 2.86 0.09 223 2.88 0.09 224 2.90 0.08 225 2.92 0.08 226 2.94 0.08 227 2.96 0.08 228 2.98 0.08 229 3.00 0.08 230 3.02 Attachment A.1 Page A. 1-6 of A. 1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq.13) f r,I : f1 * (n T0,1+1 "n TO,I) * (1*f bypass)
% f/ber,removed = l:f r,i from i=O to i 0.0024 86.0%
0.0024 86.2%
0.0023 86.5%
0.0023 86.7%
0.0023 86.9%
0.0022 87.2%
0.0022 87.4%
0.0021 87.6%
0.0021 87.8%
0.0021 88.0%
0.0020 88.2%
0.0020 88.4%
0.0020 88.6%
0.0019 88.8%
0.0019 89.0%
0.0019 89.2%
0.0018 89.4%
0.0018 89.5%
0.0018 89.7%
0.0017 89.9%
0.0017 90.1%
0.0017 90.2%
0.0017 90.4%
0.0016 90.6%
0.0016 90.7%
0.0016 90.9%
0.0016 91.0%
0.0015 91.2%
0.0015 91.3%
0.0015 91.5%
0.0014 91.6%
0.0014 91.8%
0.0014 91.9%
0.0014 92.1%
0.0014 92.2%
0.0013 92.3%
0.0013 92.4%
AttA.1
Calculation 2014-04466 Revision 1 A
B 1 Strainer Bypass Fraction, fbypass 2
Number of Pool Fraction of Fiber Mass in Turnovers Pool (Eq. 4 & 12) nro f 0 = 1.0 3
f1 =
f1 fr,1-1 (i ~ 1) 4 0 1
5 =A4+0.01
=B4-C4 6 =A5+0.01
=B5-C5 7 =A6+0.01
=B6-C6 8 =A7+0.01
=B7-C7 9 =A8+0.01
=88-C8 10 =A9+0.01
=B9-C9 11 =A10+0.01
=810-C10 12 =A11+0.01
=B11-C11 13 =A12+0.01
=B12-C12 14 =A13+0.01
=813-C13 15 =A14+0.01
=B14-C14 16 =A15+0.01
=B15-C15 17 =A16+0.01
=816-C16 18 =A17+0.01
=B17-C17 19 =A18+0.01
=818-C18 20 =A19+0.01
=B19-C19 21 =A20+0.01
=B20-C20 22 =A21+0.01
=B21-C21 23 =A22+0.01
=B22-C22 24 =A23+0.01
=B23-C23 25 =A24+0.01
=B24-C24 26 =A25+0.01
=825-C25 27 =A26+0.01
=826-C26 28 =A27+0.01
=B27-C27 29 =A28+0.01
=B28-C28 30 =A29+0.01
=829-C29 31 =A30+0.01
=830-C30 32 =A31+0.01
=831-C31 33 =A32+0.01
=B32-C32 34 =A33+0.01
=833-C33 35 =A34+0.01
=B34-C34 36 =A35+0.01
=835-C35 37 =A36+0.01
=836-C36 38 =A37+0.01
=837-C37 39 =A38+0.01
=838-C38 40 =A39+0.01
=B39-C39 Attachment A.1 Page A.1-7 of A.1-12 c
D 0.15 Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,t = f1 * (n ro,1+1 - n ro,1) * (1-f bypass)
% flber,removed = If r,l from i=O to i
={(A5-A4))*84*(1-$C$1)
=SUM($C$4:C4)
=((A6-A5))*85*(1-$C$1)
=SUM($C$4:C5)
=((A7-A6))*86*(1-$C$1)
=SUM($C$4:C6)
=((A8-A7))*87*(1-$C$1)
=SUM($C$4:C7)
=((A9-A8))*88*(1-$C$1)
=SUM($C$4:C8)
=((A1 O-A9))*89*(1-$C$1)
=SUM($C$4:C9)
=((A11-A10))*810*(1-$C$1)
=SUM($C$4:C10)
=((A12-A 11 ))*811 *(1-$C$1)
=SUM($C$4:C11)
=((A13-A12))*812*(1-$C$1)
=SUM($C$4:C12)
=((A14-A13))*813*(1-$C$1)
=SUM($C$4:C13)
=((A15-A14))*814*(1-$C$1)
=SUM($C$4:C14)
=((A 16-A15))*815*(1-$C$1)
=SUM($C$4:C15)
=((A17-A 16))*816*(1-$C$1)
=SUM($C$4:C16)
=((A18-A17))*817*(1-$C$1)
=SUM($C$4:C17)
=((A 19-A 18))*818*(1-$C$1)
=SUM($C$4:C18)
=((A20-A 19))*819*(1-$C$1)
=SUM($C$4:C19)
=((A21-A20))*820*(1-$C$1)
=SUM($C$4:C20)
=((A22-A21 ))*821 *(1-$C$1)
=SUM($C$4:C21)
=((A23-A22))*822*( 1-$C$1)
=SUM($C$4:C22)
=((A24-A23))*823*(1-$C$1)
=SUM($C$4:C23)
=((A25-A24))*824*(1-$C$1)
=SUM($C$4:C24)
=((A26-A25))*825*(1-$C$1)
=SUM($C$4:C25)
=((A27-A26))*826*(1-$C$1)
=SUM($C$4:C26)
=((A28-A27H*B27*(1-$C$1)
=SUM($C$4:C27)
=((A29-A28))*828*(1-$C$1)
=SUM($C$4:C28)
=( (A30-A29))*829*( 1-$C$1)
=SUM($C$4:C29)
=((A31-A30))*830*(1-$C$1)
=SUM($C$4:C30)
=((A32-A31 ))*831 *(1-$C$1)
=SUM($C$4:C31)
=((A33-A32))*832*(1-$C$1)
=SUM($C$4:C32)
=((A34-A33))*833*(1-$C$1)
=SUM($C$4:C33)
=((A35-A34))*834*(1-$C$1)
=SUM($C$4:C34)
=((A36-A35))*835*(1-$C$1)
=SUM($C$4:C35)
=((A37-A36))*836*( 1-$C$1)
=SUM($C$4:C36)
=((A38-A37))*837*(1-$C$1)
=SUM($C$4:C37)
=((A39-A38))*838*(1-$C$1)
=SUM($C$4:C38)
=((A40-A39))*839*(1-$C$1)
=SUM($C$4:C39)
=UA41-A40))*840*(1-$C$1)
=SUM($C$4:C40)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
41 =A40+0.01 42 =A41+0.01 43 =A42+0.01 44 =A43+0.01 45 =A44+0.01 46 =A45+0.01 47 =A46+0.01 48 =A47+0.01 49 =A48+0.01 50 =A49+0.01 51 =A50+0.01 52 =A51+0.01 53 =A52+0.01 54 =A53+0.01 55 =A54+0.01 56 =A55+0.01 57 =A56+0.01 58 =A57+0.01 59 =A58+0.01 60 =A59+0.01 61 =A60+0.01 62 =A61+0.01 63 =A62+0.01 64 =A63+0.01 65 =A64+0.01 66 =A65+0.01 67 =A66+0.01 68 =A67+0.01 69 =A68+0.01 70 =A69+0.01 71 =A70+0.01 72 =A71+0.01 73 =A72+0.01 74 =A73+0.01 75 =A74+0.01 76 =A75+0.01 77 =A76+0.01 78 =A77+0.01 79 =A78+0.01 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f I : f 1*1
- f r,1*1 (i ~ 1)
=840-C40
=841-C41
=842-C42
=843-C43
=844-C44
=845-C45
=846-C46
=847-C47
=848-C48
=849-C49
=850-C50
=851-C51
=852-C52
=853-C53
=854-C54
=855-C55
=856-C56
=857-C57
=858-C58
=859-C59
=860-C60
=861-C61
=862-C62
=863-C63
=864-C64
=865-C65
=866-C66
=867-C67
=868-C68
=869-C69
=870-C70
=871-C71
=872-C72
=873-C73
=874-C74
=875-C75
=876-C76
=877-C77
=878-C78 Attachment A.1 Page A.1-8 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) fr,1 =f1 *(nro,1+1 -nro,1) *(1-fbypass)
% flber,removed = J:f r,I from i=O to i
=UA42-A41 ))*841 *(1-$C$1 l
=SUM($C$4:C41)
=((A43-A42))*842*(1-$C$1)
=SUM($C$4:C42)
=((A44-A43))*843*(1-$C$1)
=SUM($C$4:C43)
=((A45-A44 ))*844*(1-$C$1)
=SUM($C$4:C44)
=( (A46-A45) )*845*( 1-$C$1 )
=SUM($C$4:C45)
=UA47-A46))*846*(1-$C$1)
=SUM($C$4:C46)
=((A48-A47))*847*(1-$C$1)
=SUM($C$4:C47)
=((A49-A48))*848*(1-$C$1)
=SUM($C$4:C48)
=((A50-A49))*849*(1-$C$1)
=SUM($C$4:C49)
=((A51-A50))*850*(1-$C$1)
=SUM($C$4:C50)
=UA52-A51 ))*851 *(1-$C$1)
=SUM($C$4:C51)
=((A53-A52))*852*(1-$C$1)
=SUM($C$4:C52)
=((A54-A53))*853*(1-$C$1)
=SUM($C$4:C53)
=UA55-A54))*854*(1-$C$1)
=SUM($C$4:C54 l
=((A56-A55))*855*(1-$C$1)
=SUM($C$4:C55)
=UA57-A56))*856*(1-$C$1 l
=SUM($C$4:C56)
=((A58-A57))*857*{1-$C$1)
=SUM($C$4:C57)
=((A59-A58))*858*(1-$C$1)
=SUM{$C$4:C58)
=( (A60-A59) )*859*( 1-$C$1 )
=SUM($C$4:C59)
=((A61-A60))*860*{1-$C$1)
=SUM($C$4:C60)
=((A62-A61 ))*861 *(1-$C$1)
=SUM($C$4:C61)
=((A63-A62)}*862*(1-$C$1)
=SUM($C$4:C62)
=((A64-A63))*863*(1-$C$1)
=SUM($C$4:C63)
=((A65-A64))*864*(1-$C$1)
=SUM1$C$4:C64)
=((A66-A65)}*865*(1-$C$1)
=SUM($C$4:C65)
=((A67-A66))*866*( 1-$C$1)
=SUM($C$4:C66)
=((A68-A67))*867*(1-$C$1)
=SUM($C$4:C67)
=((A69-A68))*868*(1-$C$1)
=SUM($C$4:C68)
=((A70-A69)}*869*(1-$C$1)
=SUM($C$4:C69)
=((A71-A70))*870*(1-$C$1)
=SUM($C$4:C70)
=((A72-A71 ))*871 *(1-$C$1)
=SUM{$C$4:C71)
=((A73-A72))*872*(1-$C$1)
=SUM($C$4:C72)
=((A7 4-A73))*873*(1-$C$1)
=SUM($C$4:C73)
=((A75-A7 4))*874*(1-$C$1)
=SUM($C$4:C74)
=((A76-A75))*875*(1-$C$1)
=SUM($C$4:C75)
=((A77-A76))*876*(1-$C$1)
=SUM($C$4:C76)
=((A78-A77))*877*(1-$C$1)
=SUM($C$4:C77l
=((A79-A78))*878*(1-$C$1)
=SUM($C$4:C78)
=((A80-A79ll*B79*(1-$C$1 l
=SUM($C$4:C79)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
80 =A79+0.01 81 =A80+0.01 82 =A81+0.01 83 =A82+0.01 84 =A83+0.01 85 =A84+0.01 86 =A85+0.01 87 =A86+0.01 88 =A87+0.01 89 =A88+0.01 90 =A89+0.01 91 =A90+0.01 92 =A91+0.01 93 =A92+0.01 94 =A93+0.01 95 =A94+0.01 96 =A95+0.01 97 =A96+0.01 98 =A97+0.01 99 =A98+0.01 100 =A99+0.01 101 =A100+0.01 102 =A101+0.01 103 =A102+0.01 104 =A103+0.01 105 =A104+0.01 106 =A105+0.01 107 =A106+0.01 108 =A107+0.01 109 =A108+0.01 110 =A109+0.01 111 =A110+0.01 112 =A111+0.01 113 =A112+0.01 114 =A113+0.01 115 =A114+0.01 116 =A115+0.01 117 =A116+0.01 118 =A117+0.01 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) fo = 1.0 f, = f1.1 - f r,/*1 (i 2?: 1)
=879-C79
=880-C80
=881-C81
=882-C82
=883-C83
=884-C84
=885-C85
=886-C86
=887-C87
=888-C88
=889-C89
=890-C90
=891-C91
=892-C92
=893-C93
=894-C94
=895-C95
=896-C96
=897-C97
=898-C98
=899-C99
=8100-C100
=8101-C101
=8102-C102
=8103-C103
=8104-C104
=8105-C105
=8106-C106
=8107-C107
=8108-C108
=8109-C109
=8110-C110
=8111-C111
=8112-C112
=8113-C113
=8114-C114
=8115-C115
=8116-C116
=8117-C117 Attachment A. 1 Page A.1-9 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,I = f, * (n ro,1+1 - n ro,1) * (1-f bypass)
% nber,removed =,Ef r,I from i=O to i
=((A81-A80))*880*(1-$C$1)
=SUM($C$4:C80)
=((A82-A81 ))*881 *(1-$C$1)
=SUM($C$4:C81)
=((A83-A82))*882*(1-$C$1)
=SUM($C$4:C82)
=((A84-A83))*883*(1-$C$1)
=SUM($C$4:C83)
=((A85-A84))*884*(1-$C$1)
=SUM($C$4:C84)
=((A86-A85))*885*(1-$C$1)
=SUM($C$4:C85)
=((A87-A86))*886*(1-$C$1)
=SUM($C$4:C86)
=((A88-A87))*887*(1-$C$1)
=SUM($C$4:C87)
=((A89-A88))*888*(1-$C$1)
=SUM($C$4:C88)
=((A90-A89))*889*{1-$C$1)
=SUM($C$4:C89)
=((A91-A90))*890*(1-$C$1)
=SUM($C$4:C90)
=((A92-A91 ))*891 *(1-$C$1)
=SUM($C$4:C91)
=((A93-A92))*892*(1-$C$1)
=SUM($C$4:C92)
=((A94-A93))*893*(1-$C$1)
=SUM($C$4:C93)
=((A95-A94))*894*(1-$C$1)
=SUM($C$4:C94)
=((A96-A95))*895*(1-$C$1)
=SUM($C$4:C95)
=((A97-A96))*896*(1-$C$1)
=SUM($C$4:C96)
=((A98-A97))*897*(1-$C$1)
=SUM($C$4:C97)
=( (A99-A98) )*898*( 1-$C$1)
=SUM($C$4:C98)
=((A 1 OO-A99) )*899*(1-$C$1)
=SUM($C$4:C99)
=((A101-A 100))*8100*(1-$C$1)
=SUM($C$4:C100)
=((A102-A101))*8101 *(1-$C$1)
=SUM($C$4:C101)
=((A 103-A 102))*8102*(1-$C$1)
=SUM($C$4:C102)
=((A104-A103))*8103*(1-$C$1)
=SUMf$C$4:C103)
=((A105-A104))*8104*(1-$C$1)
=SUM($C$4:C104)
=((A 106-A 105))*8105*(1-$C$1)
=SUM($C$4:C105)
=((A107-A 106))*8106*(1-$C$1)
=SUM($C$4:C106)
=((A 108-A107))*8107*(1-$C$1)
=SUM($C$4:C107)
=((A 109-A 108))*8108*(1-$C$1)
=SUM($C$4:C108)
=((A 110-A 109))*8109*(1-$C$1)
=SUM($C$4:C109)
=((A111-A110))*8110*(1-$C$1)
=SUM($C$4:C110)
=((A112-A111))*8111*(1-$C$1)
=SUM($C$4:C 111)
=((A113-A112))*8112*(1-$C$1)
=SUM($C$4:C112)
=((A 114-A113))*8113*(1-$C$1)
=SUM($C$4:C113)
=((A115-A114))*8114*(1-$C$1)
=SUM($C$4:C114)
=((A116-A115))*8115*(1-$C$1)
=SUM($C$4:C115)
=((A117-A116))*8116*(1-$C$1)
=SUMf$C$4:C116)
=((A 118-A 117))*8117*(1-$C$1)
=SUM($C$4:C117)
=((A119-A118))*8118*(1-$C$1)
=SUM($C$4:C118)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers Oro 3
119 =A118+0.01 120 =A119+0.01 121 =A120+0.01 122 =A121+0.01 123 =A122+0.01 124 =A123+0.01 125 =A124+0.01 126 =A125+0.01 127 =A126+0.01 128 =A127+0.01 129 =A128+0.01 130 =A129+0.01 131 =A130+0.01 132 =A131+0.01 133 =A132+0.01 134 =A133+0.01 135 =A134+0.01 136 =A135+0.01 137 =A136+0.01 138 =A137+0.01 139 =A138+0.01 140 =A139+0.01 141 =A140+0.01 142 =A141+0.01 143 =A142+0.01 144 =A143+0.01 145 =A144+0.01 146 =A145+0.01 147 =A146+0.01 148 =A147+0.01 149 =A148+0.01 150 =A149+0.01 151 =A150+0.01 152 =A151+0.01 153 =A152+0.01 154 =A153+0.01 155 =A154+0.02 156 =A155+0.02 157 =A156+0.02 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f I : f 1-1
- f r,1-1 (i i2:: 1)
=8118-C118
=8119-C119
=8120-C120
=8121-C121
=8122-C122
=8123-C123
=8124-C124
=8125-C125
=8126-C126
=8127-C127
=8128-C128
=8129-C129
=8130-C130
=8131-C131
=8132-C132
=8133-C133
=8134-C134
=8135-C135
=8136-C136
=8137-C137
=8138-C138
=8139-C139
=8140-C140
=8141-C141
=8142-C142
=8143-C143
=8144-C144
=8145-C145
=8146-C146
=8147-C147
=8148-C148
=8149-C149
=8150-C150
=8151-C151
=8152-C152
=8153-C153
=8154-C154
=8155-C155
=8156-C156 Attachment A.1 Page A.1-1 O of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) fr,1 =f1 "(nro,1+1 -nro,1)"(1-fbypassJ
% nber,removed = If r,t from i=O to i
=<<A120-A119))*8119*(1-$C$1 l
=SUM($C$4:C119)
=((A 121-A 120) )*8120*(1-$C$1)
=SUM($C$4:C120)
=((A 122-A121))*8121 *(1-$C$1)
=SUM($C$4:C121)
=((A 123-A122))*8122*(1-$C$1 l
=SUM($C$4:C122)
=((A 124-A123))*8123*(1-$C$1)
=SUM($C$4:C123)
=((A125-A 124))*8124*(1-$C$1)
=SUM($C$4:C124)
=((A 126-A125))*8125*(1-$C$1 l
=SUM($C$4:C125)
=((A127-A 126))*8126*(1-$C$1)
=SUM($C$4:C126)
=((A128-A 127))*8127*(1-$C$1 l
=SUM($C$4:C127)
=((A129-A 128))*8128*(1-$C$1)
=SUM($C$4:C128)
=<<A130-A129))*8129*(1-$C$1)
=SUM($C$4:C129)
=((A 131-A 130))*8130*(1-$C$1)
=SUM($C$4:C130)
=((A 132-A 131))*8131 *(1-$C$1)
=SUM($C$4:C131)
=((A 133-A 132))*8132*( 1-$C$1 l
=SUM($C$4:C132)
=((A134-A133))*8133*(1-$C$1)
=SUM($C$4:C133)
=<<A135-A 134))*8134*(1-$C$1)
=SUM($C$4:C134)
=((A 136-A 135))*8135*(1-$C$1)
=SUM($C$4: C 135)
=((A 137-A 136))*8136*(1-$C$1)
=SUM($C$4:C136)
=((A138-A 137))*8137*(1-$C$1)
=SUM($C$4:C137)
=((A139-A 138))*8138*(1-$C$1)
=SUM($C$4:C138)
=((A 140-A139))*8139*(1-$C$1)
=SUM($C$4:C139)
=((A 141-A 140))*8140*(1-$C$1)
=SUM($C$4:C140)
=((A 142-A 141))*8141*(1-$C$1)
=SUM($C$4:C141)
=((A 143-A142))*8142*(1-$C$1)
=SUM($C$4:C142)
=((A144-A 143))*8143*(1-$C$1)
=SUM($C$4:C143)
=<<A 145-A144))*8144*(1-$C$1)
=SUM($C$4:C144)
=((A 146-A 145))*8145*(1-$C$1 l
=SUM($C$4:C145)
=((A 147-A 146))*8146*(1-$C$1)
=SUM($C$4:C146)
=((A 148-A147))*8147*(1-$C$1)
=SUM($C$4:C147)
=((A149-A148))*8148*(1-$C$1 l
=SUM($C$4:C148)
=((A150-A149))*8149*(1-$C$1)
=SUM($C$4:C149)
=((A 151-A150))*8150*(1-$C$1 l
=SUM($C$4:C150)
=((A 152-A 151))*8151 *(1-$C$1)
=SUM($C$4:C151)
=((A153-A152))*8152*(1-$C$1)
=SUM($C$4:C152)
=((A 154-A153))*8153*(1-$C$1 l
=SUM($C$4:C153)
=((A155-A 154))*8154*(1-$C$1)
=SUM($C$4:C154)
=((A156-A155))*8155*(1-$C$1 l
=SUM($C$4:C155)
=((A157-A 156))*8156*(1-$C$1)
=SUM($C$4:C156)
=<<A 158-A 157))*8157*(1-$C$1)
=SUM($C$4:C157)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
158 =A157+0.02 159 =A158+0.02 160 =A159+0.02 161 =A160+0.02 162 =A161+0.02 163 =A162+0.02 164 =A163+0.02 165 =A164+0.02 166 =A165+0.02 167 =A166+0.02 168 =A167+0.02 169 =A168+0.02 170 =A169+0.02 171 =A170+0.02 172 =A171+0.02 173 =A172+0.02 174 =A173+0.02 175 =A174+0.02 176 =A175+0.02 177 =A176+0.02 178 =A177+0.02 179 =A178+0.02 180 =A179+0.02 181 =A180+0.02 182 =A181+0.02 183 =A182+0.02 184 =A183+0.02 185 =A184+0.02 186 =A185+0.02 187 =A186+0.02 188 =A187+0.02 189 =A188+0.02 190 =A189+0.02 191 =A190+0.02 192 =A191+0.02 193 =A192+0.02 194 =A193+0.02 195 =A194+0.02 196 =A195+0.02 8
Fraction of Fiber Mass In Pool (Eq. 4 & 12) f 0 = 1.0 f, = f1.1 - f r,1-1 (i ~ 1)
=8157-C157
=8158-C158
=8159-C159
=8160-C160
=8161-C161
=8162-C162
=8163-C163
=8164-C164
=8165-C165
=8166-C166
=8167-C167
=8168-C168
=8169-C169
=8170-C170
=8171-C171
=8172-C172
=8173-C173
=8174-C174
=8175-C175
=8176-C176
=8177-C177
=8178-C178
=8179-C179
=8180-C180
=8181-C181
=8182-C182
=8183-C183
=8184-C184
=8185-C185
=8186-C186
=8187-C187
=8188-C188
=8189-C189
=8190-C190
=8191-C191
=8192-C192
=8193-C193
=8194-C194
=8195-C195 Attachment A.1 PageA.1-11 ofA.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,1 = f1 * (n ro,1+1
- n ro,iJ * (1-f bypass)
% nber,removed = J:f r,I from i=O to i
=((A 159-A158))*8158*(1-$C$1)
=SUM($C$4:C158)
=((A 160-A159))*8159*(1-$C$1)
=SUM($C$4:C159)
=<<A 161-A 160))*8160*(1-$C$1)
=SUM($C$4:C160)
=((A 162-A161 ))*8161*(1-$C$1)
=SUM($C$4:C161)
=((A 163-A 162))*8162*(1-$C$1)
=SUM($C$4:C162)
=((A 164-A163))*8163*(1-$C$1)
=SUM($C$4:C163)
=((A 165-A164))*8164*(1-$C$1)
=SUM($C$4:C164)
=((A 166-A165))*8165*(1-$C$1)
=SUM($C$4:C165)
=((A 167-A 166))*8166*(1-$C$1)
=SUM($C$4:C166)
=((A 168-A167))*8167*(1-$C$1)
=SUM($C$4:C167)
=((A 169-A168))*8168*(1-$C$1)
=SUM($C$4:C168)
=((A 170-A 169))*8169*(1-$C$1)
=SUM($C$4:C169)
=<<A 171-A 170))*8170*(1-$C$1)
=SUM($C$4:C170)
=((A 172-A 171))*8171*(1-$C$1)
=SUM($C$4:C171)
=((A 173-A172))*8172*(1-$C$1)
=SUM($C$4:C172)
=((A 174-A 173))*8173*(1-$C$1)
=SUM($C$4:C173)
=((A 175-A 174))*8174*(1-$C$1)
=SUM($C$4:C174)
=<<A176-A175))*8175*(1-$C$1)
=SUM($C$4:C175)
=((A 177-A 176))*8176*(1-$C$1)
=SUM($C$4:C176)
=((A 178-A 177))*8177*(1-$C$1)
=SUM($C$4:C177)
=((A 179-A 178))*8178*(1-$C$1)
=SUM($C$4:C178)
=((A 180-A 179))*8179*(1-$C$1)
=SUM($C$4:C179)
=((A 181-A 180))*8180*(1-$C$1)
=SUMC$C$4:C180)
=((A 182-A181))*8181*(1-$C$1)
=SUM($C$4:C181)
=((A 183-A 182))*8182*(1-$C$1)
=SUM($C$4:C182)
=((A 184-A 183))*8183*(1-$C$1)
=SUM($C$4:C183)
=((A 185-A 184))*8184*(1-$C$1)
=SUM($C$4:C184)
=((A 186-A 185))*8185*(1-$C$1)
=SUM($C$4:C185)
=((A 187-A 186))*8186*(1-$C$1)
=SUM($C$4:C186)
=((A 188-A 187))*8187*(1-$C$1)
=SUM($C$4:C187)
=((A 189-A 188))*8188*(1-$C$1)
=SUMC$C$4:C188)
=((A 190-A 189))*8189*(1-$C$1)
=SUM($C$4:C189)
=((A 191-A 190))*8190*11-$C$1)
=SUM($C$4:C190)
=((A192-A191))*8191*(1-$C$1)
=SUM($C$4:C191)
=((A 193-A 192))*8192*(1-$C$1)
=SUM($C$4:C192)
=((A 194-A193))*8193*(1-$C$1)
=SUM($C$4:C193)
=((A 195-A 194))*8194*(1-$C$1)
=SUM($C$4:C194)
=((A 196-A195))*8195*(1-$C$1)
=SUM($C$4:C195)
=((A 197-A 196))*8196*(1-$C$1)
=SUM($C$4:C196)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
197 =A196+0.02 198 =A197+0.02 199 =A198+0.02 200 =A199+0.02 201 =A200+0.02 202 =A201+0.02 203 =A202+0.02 204 =A203+0.02 205 =A204+0.02 206 =A205+0.02 207 =A206+0.02 208 =A207+0.02 209 =A208+0.02 210 =A209+0.02 211 =A210+0.02 212 =A211+0.02 213 =A212+0.02 214 =A213+0.02 215 =A214+0.02 216 =A215+0.02 217 =A216+0.02 218 =A217+0.02 219 =A218+0.02 220 =A219+0.02 221 =A220+0.02 222 =A221+0.02 223 =A222+0.02 224 =A223+0.02 225 =A224+0.02 226 =A225+0.02 227 =A226+0.02 228 =A227+0.02 229 =A228+0.02 230 =A229+0.02 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f1 = f1.1
- fr,1-1 (i 01!: 1)
=8196-C196
=8197-C197
=8198-C198
=8199-C199
=8200-C200
=8201-C201
=B202-C202
=8203-C203
=8204-C204
=8205-C205
=8206-C206
=8207-C207
=8208-C208
=8209-C209
=8210-C210
=8211-C211
=8212-C212
=8213-C213
=8214-C214
=8215-C215
=8216-C216
=8217-C217
=8218-C218
=8219-C219
=8220-C220
=8221-C221
=8222-C222
=8223-C223
=8224-C224
=B225-C225
=8226-C226
=8227-C227
=8228-C228 Attachment A.1 Page A.1-12 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 1 O)
From Pool (Eq. 13) f,,, = f, *(nro,1+1
- nro,1) * (1-fbypassJ
% nber,removed =,Ef r,I from i=O to i
=((A 198-A 197))*8197*(1-$C$1)
=SUM($C$4:C197)
=((A 199-A 198))*8198*(1-$C$1)
=SUM{$C$4:C198)
=((A200-A 199))*8199*(1-$C$1)
=SUM($C$4:C199)
=< (A201-A200))*8200*(1-$C$1)
=SUM($C$4:C200)
=((A202-A201 ))*8201 *(1-$C$1)
=SUM($C$4:C201)
=((A203-A202))*8202*(1-$C$1)
=SUM($C$4:C202)
=((A204-A203))*8203*(1-$C$1)
=SUM($C$4:C203)
=( (A205-A204) )*8204*(1-$C$1)
=SUM($C$4:C204)
=( (A206-A205) )*8205*(1-$C$1)
=SUM($C$4:C205)
=((A207-A206))*8206*(1-$C$1)
=SUM($C$4:C206)
=( (A208-A207))*8207*( 1-$C$1)
=SUM($C$4:C207)
=( (A209-A208) )*8208*( 1-$C$1 l
=SUM($C$4:C208)
=((A21 O-A209) )*8209*{1-$C$1)
=SUM($C$4:C209)
=((A211-A210))*8210*(1-$C$1)
=SUM($C$4:C210)
=((A212-A211 ))*8211 *(1-$C$1 l
=SUM($C$4:C211)
=((A213-A212))*8212*(1-$C$1)
=SUM($C$4:C212)
=((A214-A213))*8213*(1-$C$1)
=SUM($C$4:C213}
=((A215-A214})*8214*(1-$C$1)
=SUM($C$4:C214)
=({A216-A215))*8215*(1-$C$1)
=SUM($C$4:C215)
=((A217-A216))*B216*(1-$C$1)
=SUM($C$4:C216l
=((A218-A217))*8217*(1-$C$1}
=SUM($C$4:C217)
=((A219-A218))*8218*(1-$C$1)
=SUM($C$4:C218}
=((A220-A219))*8219*(1-$C$1)
=SUM($C$4:C219l
=((A221-A220))*8220*(1-$C$1)
=SUM($C$4:C220)
=((A222-A221 ))*8221 *(1-$C$1 l
=SUM($C$4:C221)
=((A223-A222))*8222*(1-$C$1)
=SUM($C$4:C222)
=((A224-A223))*8223*(1-$C$1)
=SUM($C$4:C223)
=((A225-A224))*8224*(1-$C$1)
=SUM($C$4:C224l
=( (A226-A225))*8225*( 1-$C$1)
=SUM($C$4:C225)
=((A227-A226))*8226*(1-$C$1l
=SUM($C$4:C226l
=((A228-A227}}*8227*(1-$C$1)
=SUM($C$4:C227)
=((A229-A228) )*8228*(1-$C$1)
=SUM($C$4:C228}
=( (A230-A229))*8229*(1-$C$1 l
=SUM($C$4:C229l Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 ECCS Switchover Time 3 CS Switchover Time 4 ics - tECCS 5 RH Flow= Recirc Flow 6 Number of Trains 7 Flow per Strainer 8 Volume on Floor at ~ccs 9 Volume on Floor at tcs 10 Average Volume on Floor 11 Average Volume on Floor 12 Number of Turnovers 13 14 Calculation I Case 15 ECCS Switchover Time 16 CS Switchover Time 17 tcs - tEccs 18 RH Flow = Recirc Flow 19 Number of Trains 20 Flow per Strainer 21 Volume on Floor at tEccs 22 Volume on Floor at tcs 23 Average Volume on Floor 24 Average Volume on Floor 25 Number of Turnovers 26 B
c D
Sl-90-01 Att. B Case 1 OSG tEccs 999 sec tcs 2,736 sec
.1.t 1,737 sec QRH 4,557 gpm ntrain 1
Ostr 4,557 gpm VEccs 9,769 ft3 Vcs 25,787 ft3 Vavg 17,778 ft3 Vavg 132,997 gal nro 0.99 Sl-90-01 Att. B Case 2 OSG tEccs 1, 112 sec tcs 2,849 sec
.1.t 1,737 sec QRH 1,663 gpm ntrain 1
Ostr 1,663 gpm VEccs 9,874 ft3 Vcs 25,601 ft3 Vavg 17,738 ft3 Vavg 132,694 gal nro 0.36 Attachment A.2 Page A.2-1 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01 Att. B. Case 1 RSG
---~"""
ECCS Switchover Time tECCS 999 sec CS Switchover Time tcs 2,736 sec tcs - tEccs
.1.t 1,737 sec RH Flow = Recirc Flow QRH 4,557 gpm Number of Trains n1rain 1
Flow per Strainer Ostr 4,557 gpm Volume on Floor at tEccs VECCS 9,823 ft3 Volume on Floor at tcs Vcs 26,350 ft3 Average Volume on Floor Vavg 18,087 ft3 Average Volume on Floor Vavg 135,305 gal Number of Turnovers nro 0.98 Calculation I Case Sl-90-01. Att. B. Case 2 RSG ECCS Switchover Time tECCS 1, 112 sec CS Switchover Time tcs 2,849 sec ics - tECCS Lit 1,737 sec RH Flow = Recirc Flow QRH 1,663 gpm Number of Trains ntrain 1
Flow per Strainer Ostr 1,663 gpm Volume on Floor at tEccs VECCS 9,865 ft3 Volume on Floor at tcs Vcs 26,188 ft3 Average Volume on Floor Vavg 18,027 ft3 Average Volume on Floor Vavg 134,856 gal Number of Turnovers nro 0.36 TOs Sl-90-01
Calculation 2014-04466 Revision 1 A
27 Calculation I Case 28 ECCS Switchover Time 29 CS Switchover Time 30 tes - tEees 31 RH Flow = Recirc Flow 32 Number of Trains 33 Flow per Strainer 34 Volume on Floor at tEees 35 Volume on Floor at tcs 36 Average Volume on Floor 37 Average Volume on Floor 38 Number of Turnovers 39 40 Calculation I Case 41 ECCS Switchover Time 42 CS Switchover Time 43 ics - tEees 44 RH Flow = Recirc Flow 45 Number of Trains 46 Flow per Strainer 47 Volume on Floor at tEees 48 Volume on Floor at tcs 49 Average Volume on Floor 50 Average Volume on Floor 51 Number of Turnovers B
c D
Sl-90-01 Att. B Case 3 OSG tEees 1,029 sec tes 2,766 sec At 1,737 sec QRH 4,557 gpm ntrain 1
Ostr 4,557 gpm VEees 9,676 ft3 Yes 25,739 ft3 Vavg 17,708 ft3 Vavg 132,470 gal nrn 1.00 Sl-90-01 Att. B. Case 4 OSG tEees 574 sec tes 1,490 sec At 916 sec QRH 7,797 gpm ntrain 2
Ostr 3,899 gpm VEees 11, 125 ft3 Yes 24, 109 ft3 Vavg 17,617 ft3 Vavg 131,793 gal nrn 0.90 Attachment A.2 Page A.2-2 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01 Att. B. Case 3 RSG ECCS Switchover Time tEees 1,029 sec CS Switchover Time tes 2,766 sec ics - tEees At 1,737 sec RH Flow= Recirc Flow QRH 4,557 gpm Number of Trains n1rain 1
Flow per Strainer Qstr 4,557 gpm Volume on Floor at tEees VEees 9,728 ft3 Volume on Floor at tes Yes 26,308 ft3 Average Volume on Floor Vavg 18,018 ft3 Average Volume on Floor Vavg 134,793 gal Number of Turnovers nrn 0.98 Calculation I Case Sl-90-01. Att. B. Case 4 RSG ECCS Switchover Time tEees 574 sec CS Switchover Time tes 1,490 sec ics - tEees At 916 sec RH Flow = Recirc Flow QRH 7,797 gpm Number of Trains ntrain 2
Flow per Strainer Ostr 3,899 gpm Volume on Floor at tEees VEees 11,317 ft3 Volume on Floor at tes Yes 25,338 ft3 Average Volume on Floor Vavg 18,328 ft3 Average Volume on Floor Vavg 137,108 gal Number of Turnovers nrn 0.87 TOs Sl-90-01
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 ECCS Switchover Time 3 CS Switchover Time 4 tcs - tEccs 5 RH Flow = Recirc Flow 6 Number of Trains 7 Flow per Strainer 8 Volume on Floor at tEccs 9 Volume on Floor at tcs 10 Average Volume on Floor 11 Average Volume on Floor 12 Number of Turnovers 13 14 Calculation I Case 15 ECCS Switchover Time 16 CS Switchover Time 17 ics - tEccs 18 RH Flow= Recirc Flow 19 Number of Trains 20 Flow per Strainer 21 Volume on Floor at ~ccs 22 Volume on Floor at tcs 23 Average Volume on Floor 24 Average Volume on Floor 25 Number of Turnovers 26 B
c D
Sl-90-01, Att. B, Case 1 OSG tEccs 999 sec tcs 2736 sec Lit
=C3-C2 sec QRH 4557 gpm ntrain 1
Ostr
=C5/C6 gpm VEccs 9769 ft3 Vcs 25787 ft3 Vavg
=(C8+C9)/2 ft3 Vavg
=C10*7.481 gal nm
=C5*C4/60/C 11 Sl-90-01 Att. B, Case 2 OSG tEccs 1112 sec ics 2849 sec Lit
=C16-C15 sec QRH 1663 gpm ntrain 1
Ostr
=C18/C19 gpm VECCS 9874 ft3 Vcs 25601 ft3 Vavg
=(C21 +C22)/2 ft3 Vavg
=C23*7.481 gal nm
=C18*C17/60/C24 Attachment A.2 Page A.2-3 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01, Att. B, Case 1 RSG ECCS Switchover Time tEccs 999 sec CS Switchover Time tcs 2736 sec tcs - tEccs Lit
=H3-H2 sec RH Flow= Recirc Flow QRH 4557 gpm Number of Trains ntrain 1
Flow per Strainer Ostr
=H5/H6 gpm Volume on Floor at tEccs VECCS 9823 ft3 Volume on Floor at tcs Vcs 26350 ft3 Average Volume on Floor Vavg
=(H8+H9)/2 ft3 Average Volume on Floor Vavg
=H10*7.481 gal Number of Turnovers nTo
=H5*H4/60/H 11 Calculation I Case Sl-90-01, Att. B, Case 2 RSG ECCS Switchover Time tEccs 1112 sec CS Switchover Time tcs 2849 sec tcs - tECCS Lit
=H16-H15 sec RH Flow = Recirc Flow QRH 1663 gpm Number of Trains ntrain 1
Flow per Strainer Ostr
=H18/H19 gpm Volume on Floor at tEccs VECCS 9865 ft3 Volume on Floor at tcs Vcs 26188 ft3 Average Volume on Floor Vavg
=(H21 +H22)/2 ft3 Average Volume on Floor Vavg
=H23*7.481 gal Number of Turnovers nm
=H18*H17/60/H24 TOs Sl-90-01 (Eqs)
Calculation 2014-04466 Revision 1 A
27 Calculation I Case 28 ECCS Switchover Time 29 CS Switchover Time 30 tcs - tECCS 31 RH Flow = Recirc Flow 32 Number of Trains 33 Flow per Strainer 34 Volume on Floor at ~ccs 35 Volume on Floor at tcs 36 Average Volume on Floor 37 Average Volume on Floor 38 Number of Turnovers 39 40 Calculation I Case 41 ECCS Switchover Time 42 CS Switchover Time 43 tcs - tEccs 44 RH Flow = Recirc Flow 45 Number of Trains 46 Flow per Strainer 47 Volume on Floor at tEccs 48 Volume on Floor at tcs 49 Average Volume on Floor 50 Average Volume on Floor 51 Number of Turnovers B
c D
Sl-90-01, Att. B, Case 3 OSG tEccs 1029 sec tcs 2766 sec
.!lt
=C29-C28 sec QRH 4557 gpm ntrain 1
Os1r
=C31/C32 gpm VECCS 9676 ft3 Vcs 25739 ft3 Vavg
=(C34+C35)/2 ft3 Vavg
=C36*7.481 gal nro
=C31 *C30/60/C37 Sl-90-01, Att. B Case 4 OSG tEccs 574 sec tcs 1490 sec dt
=C42-C41 sec QRH 7797 gpm ntrain 2
Os1r
=C44/C45 gpm VEccs 11125 ft3 Vcs 24109 ft3 Vavg
=(C47+C48)/2 ft3 Vavg
=C49*7.481 gal nro
=C44*C43/60/C50 Attachment A.2 Page A.2-4 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01, Att. B, Case 3 RSG ECCS Switchover Time tEccs 1029 sec CS Switchover Time tcs 2766 sec tcs - tEccs dt
=H29-H28 sec RH Flow= Recirc Flow QRH 4557 gpm Number of Trains ntrain 1
Flow per Strainer Qstr
=H31/H32 gpm Volume on Floor at tEccs VECCS 9728 ft3 Volume on Floor at tcs Vcs 26308 ft3 Average Volume on Floor Vavg
=(H34+H35)/2 ft3 Average Volume on Floor Vavg
=H36*7.481 gal Number of Turnovers nro
=H31 *H30/60/H37 Calculation I Case Sl-90-01, Att. B, Case 4 RSG ECCS Switchover Time tECCS 574 sec CS Switchover Time tcs 1490 sec tcs - tECCS
.!lt
=H42-H41 sec RH Flow= Recirc Flow QRH 7797 gpm Number of Trains ntrain 2
Flow per Strainer Ostr
=H44/H45 gpm Volume on Floor at tEccs VECCS 11317 ft3 Volume on Floor at tcs Vcs 25338 ft3 Average Volume on Floor Vavg
=(H47+H48)/2 ft3 Average Volume on Floor Vavg
=H49*7.481 gal Number of Turnovers nro
=H44*H43/60/H50 TOs Sl-90-01 (Eqs)
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 EGGS Switchover Initiation Time 3 RH Pumps Switched Over 4 RWST Volume Remaining at IRH,f RWST Outflow fort <': tRH.f Assuming RWST to RH 5 Pump Suction Isolation Valves Close 6 RWST Level at CS Switchover Initiation 7 RWST Feet oer % Level 8 RWST Gallons oer Foot 9 RWST Volume at CS Switchover Initiation 10 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 11 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 12 Switchover Initiation 13 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 14 Switchover Initiation 15 RH Pump Flow 16 Number of Trains in Recirc 17 Flow per Strainer 18 Volume on Floor at 4:ccs 19 Volume on Floor at -1560 sec in ATD-0111 20 Approximate Volume on Floor at tcs.;
21 Average Volume on Floor 22 Average Volume on Floor 23 Number of Turnovers 24 Attachment A.2 Page A.2-5 of A.2-12 B
c D
E ATD-0111 Ac 1>. H. BRW 1 RSG 4:ccs 928.7 sec Sht 1 of ATD-0111 Appendix H IRH,f 1,156.7 sec Sht 1 of ATD-0111 Appendix H VRWST,tRH,f 114,151 gal Sht 1 of ATD-0111 Appendix H QRWST,tRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FoP 0.54833 ttl°lo SITH-1, P. 11 GpF 8,351.6,Qal/ft SITH-1, p.14 VRWST,!CS,i 54,953.2 gal
= L0-3
- FpP
- GpF VRWST,!CS,i '
7,346.7 ft3
= V RWST.tCS.i / 7.48 galfft3 VtRH,f-tCS,i 59,197.8 gal
= VRWST.tRH,f - VRWST,tCS,i imH,f-ICS,i 405.8 sec
= (V1RH.r-1cs,; I QRwsT,tRH,t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion ics,;
1,562.5 sec
= tRH,f + tRH,f-!CS,i L\\t 633.8 sec
= ics,; - tEccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix H Ostr 3,899 gpm
= QRH I ntrain VECCS 32,589 ft3 Sht 12 of A TD-0111 Appendix H V1550 59,798 ft3 Sht 12 of ATD-0111 Appendix H Vcs 52,451 ft3
= V156o - VRwsT.tes;'
Vavg 42,520 ft3
= (VEccs + Vcs) / 2 Vavg '
318,051 gal
= Va\\/O
- 7.48 gal/ft3 nro 0.26
= QRH
- L\\tl (60 sec/min
- V avg')
TOs ATD-0111
Calculation 2014-04466 Revision 1 A
25 Calculation I Case 26 ECCS Switchover Initiation Time 27 RH Pumps Switched Over 28 RWST Volume Remaining at tRH.f RWST Outflow fort ~ tRH,f Assuming RWST to RH 29 Pump Suction Isolation Valves Close 30 RWST Level at CS Switchover Initiation 31 RWST Feet per % Level 32 RWST Gallons per Foot 33 RWST Volume at CS Switchover Initiation 34 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 35 Comoletion and CS Switchover Initiation Time between RH Switchover Completion and CS 36 Switchover Initiation 37 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 38 Switchover Initiation 39 RH Pump Flow 40 Number of Trains in Recirc 41 Flow per Strainer 42 Volume on Floor at ~ccs 43 Volume on Floor at -1560 sec in ATD-0111 44 Approximate Volume on Floor at tcs,;
45 Average Volume on Floor 46 Average Volume on Floor 47 Number of Turnovers 48 Attachment A.2 Page A.2-6 of A.2-12 B
c D
~ccs 928.7 sec Sht 1 of ATD-0111 Appendix I
~H,f 1,156.7 sec Sht 1 of ATD-0111 Appendix I VRwsT.tRH.f 114,151 gal Sht 1 of ATD-0111 Appendix I QRWST,IRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, o. 11 GpF 8,351.6 Qallft SITH-1, p. 14 VRWST,tCS,i 54,953.2 gal
= L0-3
- FpP
- GpF v
RWST,tCS,i 7,346.7 ft3
= V Rwsr.tcs ; I 7.48 gallft3 VtRH,f-tCS,i 59,197.8 gal
= VRWST,tRH,f - VRWST,tCS,i ftRH. f-tCS,i 405.8 sec
= <V1RH,t-1cs,i I ORwsr.tRH,t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.;
1,562.5 sec
= tRH,f + ~H,f-tCS,i At 633.8 sec
= tcs,; - teccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix I Ostr 3,899 gpm
= QRH I ntrain Veccs 32,655 ft3 Sht 12 of ATD-0111 Appendix I V1550 59,927 ft3 Sht 12 of A TD-0111 Appendix I Vcs 52,580 ft3
= V1560 - VRWST,tCSi '
Vavg 42,618 ft3
= <Veccs + Vcs) / 2 Vavg '
318,780 gal
= V_,
- 7.48 gallft3 nro 0.26
= QRH *At I (60 sec/min
- Vavg')
TOsATD-0111
Calculation 2014-04466 Revision 1 A
49 Calculation I Case 50 ECCS Switchover Initiation Time 51 RH Pumps Switched Over 52 RWST Volume Remaining at ~H.t RWST Outflow fort ;:: tRH.f Assuming RWST to RH 53 Pump Suction Isolation Valves Close 54 RWST Level at CS Switchover Initiation 55 RWST Feet per% Level 56 RWST Gallons oer Foot 57 RWST Volume at CS Switchover Initiation 58 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 59 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 60 Switchover Initiation 61 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 62 Switchover Initiation 63 RH Pump Flow 64 Number of Trains in Recirc 65 Flow per Strainer 66 Volume on Floor at fi=ccs 67 Volume on Floor at -1560 sec in ATD-0111 68 Approximate Volume on Floor at tcs.i 69 Average Volume on Floor 70 Average Volume on Floor 71 Number of Turnovers 72 Attachment A.2 Page A.2-7 of A.2-12 B
c D
E ATD-0111 Ar 11. J BRW 2 OSG fi=ccs 928.7 sec Sht 1 of ATD-0111 Appendix J
~H.f 1,156.7 sec Sht 1 of ATD-0111 Appendix J VRWST,IRH,f 114,151 gal Sht 1 of ATD-0111 Appendix J QRWST,IRH,f 8,752 gpm
= Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, P. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GoF 8,351.6 1aal/ft SITH-1, P. 14 VRwsr.tes.i 54,953.2 gal
= L0-3
- FpP
- GpF VRwsr.tes.i I
7,346.7 ft3
= VRwsrtcs.i I 7.48 gal/ft3 VtRH.f-tCS,i 59,197.8 gal
= VRwsr.tRH,t - VRwsr.tcs.i
!tRH,f-tCS,i 405.8 sec
= CVtRH.t-tcs.i I ORwsr.tRH.r)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.i 1,562.5 sec
= tRH,f + tRH.f-tCS,i i1t 633.8 sec
= tcs.i - tEccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix J Ostr 3,899 gpm
= QRH I ntrain VEccs 32,144 ft3 Sht 12 of ATD-0111 Appendix J V156o 59,188 ft3 Sht 12 of ATD-0111 Appendix J Vcs 51,841 ft3
= V15so - VRwsr.1csi 1
Vavg 41,993 ft3
= <VEccs + Vcs) / 2 Vavg 1
314,105 gal
= Vava
- 7.48 gal/ft3 nro 0.26
= QRH
- i1t I (60 sec/min
- V avg')
TOs ATD-0111
Calculation 2014-04466 Revision 1 A
13 Calculation I Case 74 ECCS Switchover Initiation Time 75 RH Pumps Switched Over 76 RWST Volume Remaining at ~H.t RWST Outflow fort ~ ~H.t Assuming RWST to RH 77 Pump Suction Isolation Valves Close 78 RWST Level at CS Switchover Initiation 79 RWST Feet oer % Level 80 RWST Gallons nAr Foot 81 RWST Volume at CS Switchover Initiation 82 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 83 Comoletion and CS Switchover Initiation nme between RH Switchover Completion and CS 84 Switchover Initiation 85 nme at CS Switchover Initiation Time between RH Switchover Initiation and CS 86 Switchover Initiation 87 RH Pump Flow 88 Number of Trains in Recirc 89 Flow per Strainer 90 Volume on Floor at feces 91 Volume on Floor at -1560 sec in ATD-0111 92 Approximate Volume on Floor at tcs.1 93 Average Volume on Floor 94 Average Volume on Floor 95 Number of Turnovers Attachment A.2 Page A.2-8 of A.2-12 B
c D
E ATD-0111 Ac :i. K. BYR 2 OSG feces 928.7 sec Sht 1 of ATD-0111 Appendix K
~H.f 1,156.7 sec Sht 1 of ATD-0111 Appendix K VRwsT.tRH.t 114,151 gal Sht 1 of A TD-0111 Appendix K QRWST.tRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FoP 0.54833 ft!Olo SITH-1 o. 11 GpF 8,351.6 IQallft SITH-1, p. 14 V RWST,ICS,I 54,953.2 gal
= L0-3
- FpP
- GpF v
= VRWSrtes i / 7.48 gallft3 V1RH,f-tCS,I 59,197.8 gal
= VRWST,IRH,f - VRWST,ICS.I
~RH,1-tCS,i 405.8 sec
= (VtRH,f..tCS,i I ORwsr.tRH.t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.1 1,562.5 sec
=
~H.f + ~H,f-tCS,I 6t 633.8 sec
= tcs.i - tECCS QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix K Ostr 3,899 gpm
= QRH / 11tra1n VECCS 32,091 ft3 Sht 12 of A TD-0111 Appendix K V1560 59,185 ft3 Sht 12 of A TD-0111 Appendix K Vcs 51,838 ft3
= V1sso - VRWSr.tes1 I
Vavg 41,965 ft3
= <VEccs + Vcs) / 2 Vavg' 313,896 gal
= V~
- 7.48 gal/ft3 nro 0.26
= QRH
- 6t I (60 sec/min
- V avg')
TOsATD-0111
Calculation 2014-04466 Revision 1 I
A 1 Calculation I Case 2 ECCS Switchover Initiation Time 3 RH Pumps Switched Over 4 RWST Volume Remaining at tRH.f RWST Outflow fort ::: tRH,t Assuming RWST to RH 5 Pump Suction Isolation Valves Close 6 RWST Level at CS Switchover Initiation RWST Feet per% Level 7
RWST Gallons per Foot 8
RWST Volume at CS Switchover Initiation 9
RWST Volume at CS Switchover Initiation 10 RWST Volume Injected between RH Switchover 11 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 12 Switchover Initiation Time at CS Switchover Initiation 13 Time between RH Switchover Initiation and CS 14 Switchover Initiation RH Pump Flow 15 16 Number of Trains in Recirc 17 Flow per Strainer 18 Volume on Floor at ~ccs 19 Volume on Floor at -1560 sec in ATD-0111 20 Approximate Volume on Floor at ics,;
21 Average Volume on Floor 22 Average Volume on Floor 23 Number of Turnovers 24 Attachment A.2 Page A.2-9 of A.2-12 B
c D
E A TD-0111. AD il. H BRW 1 RSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix H tRH.f 1156.7 sec Sht 1 of ATD-0111 Appendix H VRWST,IRH.f 114151 gal Sht 1 of ATD-0111 Appendix H QRWST,tRH.f gpm = Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP ft!Olo SITH-1, p. 11 0.54833 GpF gal/ft SITH-1, p. 14 8351.6 VRWST,tCS,i gal
= L0-3
- FpP
- GpF
=C6*C7*C8 v
ft3
= VRwsT.tes,i / 7.48 gal/ft3 RWST,tCS,i
=C9/7.48 VtRH,f-tCS,i gal
= VR\\/VST,tRH,f - VRWST,tCS,i
=C4-C9
~H,f-tCS,i sec
= (VtRH,t-1cs,; I ORwsT,tRH,t)
- 60 sec/min; since this is less than 412
=C11/C5*60 sec, CS switchover begins prior to SI switchover completion tcs,;
sec
= ~H,f + tRH,f-tCS,i
=C3+C12 8t sec
= tcs,i - tECCS
=C13-C2 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix H Os1r
=C15/C16 gpm = QRH I n1ra;n VECCS 32589 ft3 Sht 12 of ATD-0111 Appendix H V1seo 59798 ft3 Sht 12 of A TD-0111 Appendix H Vcs
=C19-C10 ft3
= V1550 - VRWST,tesi Vavg
=(C18+C20)12 ft3
= (VEccs + Vcs) I 2 Vavg'
=C21*7.48 gal
= V avn
- 7.48 gal/ft3 n10
=C 15*C 14/60/C22
= QRH
- 8t I (60 sec/min* Vav9')
TOsATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
25 Calculation I Case 26 ECCS Switchover Initiation Time 27 RH Pumps Switched Over 28 RWST Volume Remaining at tRH,f RWST Outflow fort 2: tRH,f Assuming RWST to RH 29 Pump Suction Isolation Valves Close 30 RWST Level at CS Switchover Initiation 31 RWST Feet per % Level 32 RWST Gallons per Foot 33 RWST Volume at CS Switchover Initiation 34 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 35 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 36 Switchover Initiation 37 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 38 Switchover Initiation RH Pump Flow 39 40 Number of Trains in Recirc 41 Flow per Strainer 42 Volume on Floor at ~ccs 43 Volume on Floor at -1560 sec in ATD-0111 44 Approximate Volume on Floor at fcs,;
45 Average Volume on Floor 46 Average Volume on Floor 47 Number of Turnovers 48 Attachment A.2 Page A.2-10 of A.2-12 B
c D
E ATD-0111. Aa rl. I BYR 1 RSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix I tRH,f 1156.7 sec Sht 1 of ATD-0111 Appendix I VRwsT,tRH,f 114151 gal Sht 1 of ATD-0111 Appendix I QRWST,tRH,f gpm = Ocs + Ocv + 0 81 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 V RWST,tCS,i
=C30*C31*C32 gal
= L0-3
- FpP
- GpF v
I RWST,tCS,i
=C33/7.48 ft3
= VR'""'TtCS; / 7.48 gallft3 VtRH,f-tCS,i gal
= VRwsT,tRHJ - VRWST,tcs,;
=C28-C33 ttRH,1-tCS,i sec
= (VtRH,t-tcs,; I ORwsT,tRH,1)
- 60 sec/min; since this is less than 412
=C35/C29*60 sec, CS switchover begins prior to SI switchover completion ics,;
=C27+C36 sec
= tRH,f + tRH,f-tCS,i
~t sec
= ics,; - tECCS
=C37-C26 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close rltrain 2
Sht 1 of ATD-0111 Appendix I Os tr
=C39/C40 gpm = QRH I rltrain VEccs 32655 ft3 Sht 12 of ATD-0111 Appendix I V1550 59927 ft3 Sht 12 of ATD-0111 Appendix I Vcs
=C43-C34 ft3
= V1550 - VRwsT.tcs; I
Vavg
=(C42+C44)/2 ft3
= (VEccs + Vcs) I 2 Vavg I
=C45*7.48 gal
= Vavo
- 7.48 gallft3 nTo
=C39*C38/60/C46
= QRH * ~t I (60 sec/min* Vav9')
TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
49 Calculation I Case 50 EGGS Switchover Initiation Time 51 RH Pumps Switched Over 52 RWST Volume Remaining at tRH,t RWST Outflow fort <! tRH.f Assuming RWST to RH 53 Pump Suction Isolation Valves Close 54 RWST Level at CS Switchover Initiation 55 RWST Feet per % Level 56 RWST Gallons per Foot 57 RWST Volume at CS Switchover Initiation 58 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 59 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 60 Switchover Initiation 61 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 62 Switchover Initiation RH Pump Flow 63 64 Number of Trains in Recirc 65 Flow per Strainer 66 Volume on Floor at ~ccs 67 Volume on Floor at -1560 sec in ATD-0111 68 Approximate Volume on Floor at tcs.;
69 Average Volume on Floor 70 Average Volume on Floor Number of Turnovers 71 72 Attachment A.2 Page A.2-11 of A.2-12 B
c D
E ATD-0111 A111. J BRW 2 OSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix J
~H,f 1156.7 sec Sht 1 of ATD-0111 Appendix J VRWST,tRH,f 114151 gal Sht 1 of A TD-0111 Appendix J QRWST,tRH,f gpm = Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 VRWST,tCS,i
=C54 *C55*C56 gal
= L0-3
- FpP
- GpF V RWST,tCS,i I
=C57/7.48 ft3
= VRwsr.tes.i / 7.48 gal/ft3 V tRH,f-tCS,i gal
= VRWST,tRH,f - VRWST,tCS,i
=C52-C57 ttRH,f-tCS,i sec
= (VtRH.t-tes,; I ORwsT,tRH,t)
- 60 sec/min ; since this is less than 412
=C59/C53*60 sec, CS switchover begins prior to SI switchover completion tcs,;
=C51+C60 sec
= ~H,f + tRH,f-tCS,i 6t sec
= fcs,; - tECCS
=C61-C50 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix J Ostr
=C63/C64 gpm = QRH I lltrain VECCS 32144 ft3 Sht 12 of A TD-0111 Appendix J V15e0 59188 ft3 Sht 12 of ATD-0111 Appendix J Vcs
=C67-C58 ft3
= V15e0 - VRWST,tCSi '
Vavg
=(C66+C68)/2 ft3
= (VEccs + Vcs) / 2 Vavg '
=C69*7.48 gal
= Vava
- 7.48 gallft3 nro
= QRH
- 6t I (60 sec/min* Vav9')
=C63*C62/60/C70 TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
73 Calculation I Case 74 ECCS Switchover Initiation Time 75 RH Pumps Switched Over 76 RWST Volume Remaining at tRH.f RWST Outflow fort ;:: tRH,t Assuming RWST to RH 77 Pump Suction Isolation Valves Close 78 RWST Level at CS Switchover Initiation 79 RWST Feet per % Level 80 RWST Gallons per Foot 81 RWST Volume at CS Switchover Initiation 82 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 83 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 84 Switchover Initiation 85 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 86 Switchover Initiation RH Pump Flow 87 88 Number of Trains in Recirc 89 Flow per Strainer 90 Volume on Floor at ~ccs 91 Volume on Floor at -1560 sec in ATD-0111 92 Approximate Volume on Floor at tcs.i 93 Average Volume on Floor 94 Average Volume on Floor 95 Number of Turnovers Attachment A.2 Page A.2-12 of A.2-12 B
c D
E ATD-0111 All o. K BYR 2 OSG tECCS 928.7 sec Sht 1 of ATD-0111 Appendix K tRH.f 1156.7 sec Sht 1 of ATD-0111 Appendix K VRWST,tRH.f 114151 gal Sht 1 of ATD-0111 Appendix K QRWST,tRH,f gpm = Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 VRWST,tCS,i
=C78*C79*C80 gal
= L0-3
- FpP
- GpF v
RWST,tCS,i
=C81/7.48 ft3
= V Rwsr 1cs i I 7. 48 gallft3 V tRH.f-tCS,i gal
= VRwsT.tRH.t - VRwsT.tCS,i
=C76-C81 ttRH.f-tCS,i sec
= (VtRH.t-tes.i I ORwsT,tRH,t)
- 60 sec/min; since this is less than 412
=C83/C77*60 sec, CS switchover begins prior to SI switchover completion tcs,i
=C75+C84 sec
= ~H.f + tRH,f-tCS,i 8t sec
= ics.; - tEccs
=C85-C74 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close r\\rain 2
Sht 1 of ATD-0111 Appendix K Ostr
=C87/C88 gpm = QRH I Otrain VEccs 32091 ft3 Sht 12 of ATD-0111 Appendix K V1560 59185 ft3 Sht 12 of A TD-0111 Appendix K Vcs
=C91-C82 ft3
= V1560 - VRWST,teSi' Vavg
=(C90+C92)/2 ft3
= (VEccs + Vcs) I 2 Vavg'
=C93*7.48 gal
= Vavn
- 7.48 gal/ft3 nro
=C87*C86/60/C94
= QRH
- 8t I (60 sec/min* Vav9')
TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 0 Attachment B ATTACHMENT B: AVAILABLE DRIVING HEAD 1.0 Purpose Page Bl ofB3 Per Limitation 1 in Section 4.0 of the Safety Evaluation to WCAP-16793 [Ref. 2.1]
"Licensees should confirm that their plants are covered by the PWROG sponsored fuel assembly tests by confirming that the plant available hot-leg break driving head is equal to or greater than that determined as limiting in the proprietary fuel assembly tests." Therefore, the purpose of this attachment is to calculate the hot-leg break available driving head and compare it to the proprietary fuel assembly tests.
2.0 Design Input 2.1 Hot-Leg Centerline Elevation Per Drawing M-196 [Ref. 2.3] the hot-leg centerline is at an elevation of393 feet for Byron Units 1 and 2 and Braidwood Units 1 & 2.
2.2 Elevation of the Bottom of the Core Per Drawing 113E977 [Ref. 2.2] for Byron Units 1 & 2 and Braidwood Units 1 & 2 the bottom of the active core is 206.625 inches (62.625"+144")
below the center of the hot-leg (393 feet, Design Input 2.1 ). Therefore, the elevation of the bottom of the active core is 375.78 feet (393 - 206.625/12).
2.3 Elevation of Bottom of the Hot-Leg The hot-leg centerline is at an elevation of 393 feet (Design Input 2.1 ). The hot-leg piping has an inner diameter of 29 inches [Table 5.4-5 of Ref. 2.9].
Therefore, the elevation of the bottom of the hot-leg is equal to the hot-leg centerline elevation minus half the inner diameter of the hot-leg which is equal to 391.79 feet (393-29/12/2).
2.4 Steam Generator Tube Spillover Elevation The minimum steam generator tube spillover elevation for Byron and Braidwood Unit 1 is 431.8 feet [Ref. 2.10.10]. The minimum steam generator tube spillover elevation for Byron and Braidwood Unit 2 is determined by adding the elevation of the top of the steam generator pedestals [396.5 feet, Refs. 2.10.1-2.10.8] to the distance from the steam generator pedestal to the spillover elevation of the lowest tube [greater than 28.5 feet, Ref. 2.10.9]. This results in a steam generator tube spillover elevation of 425 feet for Byron and Braidwood Unit 2. Very minor differences in dimensions were noted across all of the steam generators across each station; however, the numbers used were selected to bias the steam generator tube spillover elevation lower which is conservative. For
Calculation 2014-04466 Revision 0 Attachment B Page B2 ofB3 conservatism the lowest steam generator tube spillover elevation is used for all units.
2.5 Maximum Core Temperature Analyzed The maximum core temperature does not have a significant impact on the available driving head; therefore, a bounding temperature of 300°F is used for this analysis. The saturation pressure at a temperature of 300°F is 67 psia which bounds the computed post-LOCA containment pressures in CN-CRA-10-54 [Ref. 2.4].
2.6 Minimum Core Temperature Analyzed A minimum Post-LOCA sump temperature of 120°F is used which is consistent with WCAP-17057-P [Section 6.7.1 of Ref. 2.6]. The use of a lower sump temperature (i.e. 60°F) would not change the conclusions of this analysis.
3.0 Methodology The hot-leg break available driving head is calculated using the methodology in Section 10.3.2.3 of Attachment 1 to LTR-SEE-1-10-23, Rev. 1, which is included as Attachment K to WCAP-16793-NP, Rev. 2 [Ref. 2.7]. The methodology is provided in response to RAJ # 18 in the PWROG Response to Request for Additional Information Regarding Topical Report WCAP-16793-NP [Ref. 2.8].
According to the SE to WCAP-16793, "if licensees maintain the 15 gram debris limit established for hot-leg breaks, the cold-leg break may be bounded by the hot-leg break," [page 15 of Ref. 2.1]. Therefore, because Byron/Braidwood meets the 15 gram per fuel assembly debris limit (see Attachment A) the cold-leg break driving head is not calculated herein.
The available hot-leg break driving head equals the elevation head in the downcomer and steam generator tubes up to the spillover elevation minus the elevation head in the core.
Where:
dP. = (zso - Zcore-tn )Pnc (zbrk - Zcore-1n )Pcore avml 144 144 dP avail = Available driving head (psi)
Zso =Steam Generator tube spillover elevation (ft)
Zcore-in Elevation of the bottom of the core (ft)
Zbrk Elevation of the bottom of the hot-leg (ft) poc = density in downcomer and steam generator (lbm/ft3)
Peare= density in core (lbm/ft3)
Calculation 2014-04466 Revision 0 Attachment B Page B3 ofB3 Since it is expected that the lowest density, hottest water would be in the core, it is conservatively assumed that the density in the core is equal to the density in the downcomer and steam generator tubes (i.e. Pnc = Peare).
The post-LOCA water temperature in the core can range from 120°F (Design Input 2.6) to 300°F (Design Input 2.5). The density of water at the minimum and maximum analyzed temperatures is 61.7 1bm/ft3 and 57.3 1bm/ft3, respectively [Ref.
2.5].
4.0 Results The available hot-leg break driving head therefore ranges from 13.2 to 14.2 psi.
dP. = (425-375.45 )* 57.3 _ (391.79-375.45 )* 57.3= 13.2 sid at 300oF avail 144 144 p
dP. = (425-375.45)* 61. 7 _ (391.79-375.45)* 61. 7 = 142 sid at 120oF avail 144 144 p
The above calculation is conservative since the core density is less than the downcomer density.
5.0 Conclusions Regarding Available Driving Head According to WCAP-17057-P [Bullet 1 on page 6-51 of Ref. 2.6], the testing with 15 grams of fiber per fuel assembly resulted in a maximum debris head loss of 2. 7 psi. Therefore, Byron/Braidwood, which has less than 15 grams of fiber per fuel assembly (see Attachment A) will have an available driving head that is greater than the debris head loss.
In addition, Section 10.2 of Reference 2. 7 states the following: "The AREVA testing conducted in support of this program demonstrated that 15 g of fiber/FA does not cause a blockage that will challenge LTCC, the maximum pressure drop due to debris ( dP debris) was very small and all plants have an available driving head (dPavaiI) that is considerably greater. Therefore, all PWROG plants can demonstrate LTCC is not impeded ifthe plant-specific fibrous debris load is less than or equal to 15 g of fiber/FA."
Calculation 2014-04466 Revision 0 Attachment C Page Cl of Cl ATTACHMENT C: MAXIMUM FLOW RATE PER FUEL ASSEMBLY The maximum cold-leg recirculation flow is 4,212 gpm per Section 8.3 and Table 6.2 of Calculation No. BYR06-029 I BRW-06-0016-M [Ref. 2.11]. Based on 2 train operation the maximum flow rate would be 8,424 gpm (=4,212*2). The maximum flow rate per fuel assembly is calculated to be 43.6 gpm I fuel assembly and is found by dividing the maximum cold-leg recirculation flow (8,424 gpm) by the number of fuel assemblies [193 fuel assemblies, Ref. 2.9].
Note, the hot-leg recirculation flow rate in Calculation No. BYR06-029 I BRW-06-0016-M
[Ref. 2.11] is slightly higher than the cold-leg recirculation flow rate. However, per page 64 of the SE for WCAP-16793-NP, Rev. 2, the potential for core blockage during hot-leg recirculation is bounded by cold-leg recirculation; therefore, using the maximum flow rate during cold-leg recirculation is appropriate. Also, the cold-leg recirculation flow is based on non-erosion cases since the erosion cases are representative of times further into the LOCA transient beyond hot leg switchover.
Calculation 2014-04466 Revision O Exelon Powerlabs, LLC.
Technical Services West 36400 S. Essex Road Wilmington, IL 60481-9500 www.exelonpowerlabs.com 815-458-7640 815-458-7851 fax To:
From:
Project Number:
Subject:
B. Davenport Mechanical/Structural Engineering Cantera William Treasurer (815)458-7654 william. treasurer@ExelonCorp.com EXE-82632 Sump Strainer Particle Loading Page 01 of 028 Exelon Powerlabs Water samples taken during Tests 3 and 6 of Control Components Inc.
(CCI) Large-Scale Performance Testing of Containment Sump Strainers November, 2005
Reference:
CCI specification Q.003.84748, Rev. 2, dated 11/10/05.
Date:
02/0l/2006DRAFf Exelon is involved with purchasing new strainers for the containment sumps at the Exelon PWRs.
This is being driven by an NRC Generic Safety Issue (GSI) 191, which involves post-LOCA debris blockage of the containment sump screens. For Byron & Braidwood the strainer manufacturer is Control Components Inc. (CCI).
Part of the testing of the replacement strainers involves determining the amount of fibrous &
particulate debris which can get through the sump strainer as these contaminants can impact analysis for components downstream of the strainer (e.g. reactor fuel). This has been referred to as "strainer bypass" or efficiency. During CCI large scale strainer testing, provisions were made to take water samples of the downstream flow to assist in determining the strainer bypass efficiency for various debris constituents.
Water samples of the flow stream were shipped to the Exelon Power Labs at Wilmington, IL for assistance with determining the amount of fibers and particulate debris contained in samples of the water downstream of the new strainer. The samples were taken during performance of Tests 3 and 6 The Exelon Powerlabs Quality System meets 10CFR50 Appendix B, 10CFR21, ANSI N45.2, ANSl/NCSL Z540-1, and NQA-1.
Calculation 2014-04466 Revision O Page 02 of 028 of the referenced CCI large-scale performance tests in November 2005. CCI also took downstream samples concurrently during all of the test cases. The results of this Exelon determination of fiber and particulate bypass will be used for further analysis input and as a comparison to the CCI test data.
- 1. The mg/L solids data found in Tables 1 & 2 were reported on December 2, 2005.
- 2. None of the material in all the Test 3 water samples was classified as large (greater than 0.083 inches).
- 3. Most of the particulates present in Tests 3 and 6 were non-fibrous based upon visual examination of the filters.
- 4. The fiber mass calculated from the estimated total fiber volume of the selected Test 6 samples indicated that most of the solids reported in Table 1 are due to non-fibrous material.
- 1. Measure the mass per volume of material on the water samples submitted. There are two sets; a fiber only set (Test# 6) and a fiber plus particulate set (Test# 3). Provide preliminary results on the first twenty samples from each set by December 8th (depending on the sample receipt date). Provide preliminary results on the first twenty samples within 1 week after receipt. The balance of the results within 2 weeks.
- 2. Measure the fiber dimensions from selected Test 6 filter samples, so that an estimate of the mass of the fibers can be calculated.
- 3. Take representative photographs from the feed stock material used for Test 3, all Test 3 Filters, and selected Test 6 Filters.
TEST PLAN ON MEASURING THE AMOUNT OF DEBRIS IN STRAINER WATER SAMPLES I.
Scope: Measure the mass per volume of debris in the downstream water samples passing through the strainer.
- 1.
Rinse all glassware with DI water before proceeding with each filtration.
- 2.
Shake each bottle vigorously just before filtering to suspend all fiber and debris that may have settled.
- 3.
Using a matched weight Millipore 0.8-micron filter, assemble the filtering apparatus.
- 4.
Filter an appropriate volume of water. Record the sample bottle's weight before transferring to the filter apparatus and after filtering. The difference of the sample bottle weighings is the volume of water filtered. For very lightly loaded water, this volume might be the complete 500 ml sample.
- 5.
If the entire bottle contents are used, rinse the bottle with DI water and add that to the filtering apparatus to be filtered.
- 6.
Rinse the filter assembly with DI water.
Project Number: EXE-82632 Page 2 of 28
Calculation 2014-04466 Revision O Page 03 of 028
- 7.
Carefully removed each of the matched weight filters and transfer each set to glass Petri dishes.
- 8.
Dry in an oven at 95 C (+/-3 C) for 30 minutes (ref: ASTM D2276).
- 9.
Allow the filters to cool in a desiccator.
- 10.
Weight both the blank filter and the sample filter on an analytical balance to 0.0001 g.
- 11.
Calculate the PPM (mg/l) as follows:
PPM (MG/L) =(W2-Wl)N Where W2 =Sample Weighting Wl= Blank Weighting V= Volume Used in mL (assumes density of water= 1.00 g/mL)
II.
Scope: Estimate the Relative Size of the Fibers on the filters from the Fiber Set (Test# 6).
Note that this will be a visual volume estimate under a stereoscope. The longest dimension of the fiber (bundle) will be used. Use this data to calculate the mass of fiber present.
- 1.
Verify the reticule markings with a secondary standard of known dimensions at various magnifications.
- 2.
Photograph typical fields as necessary.
- 3.
The particulate population consists of fiberglass, and possibly "stone flour, typically greater than 60 microns" particulate and "zinc powder, approximately 30 to 40 micron" particulate, and glass.
- 4.
On selected samples (based on discussions with Mr. Davenport) perform length measurements of the fiberglass on the filter membrane. Verify the fiberglass fibers' diameter.
- 5.
Under a stereoscope, examine fields of view and classify the fiberglass fiber dimensions.
Measure the length of the fibers. For the purpose of this study particles are classified as follows:
Large: >/= 0.083 inches+ 10 %
(0.0913 "= 2320 microns, 0.083" = 2110 microns)
Small: < 0.083 inches.
Note: Because of the magnifications used, particulate/fibers under approximately 20 microns are excluded.
- 6.
After the total sum the numbers of fiberglass fibers and their lengths are known, their mass can be calculated using the fiberglass's density of 159-lbs/cubic foot, the measured lengths, and the measured diameters.
- 7.
Enter the data from the fiber counting I sizing in an Excel spreadsheet for final calculations.
Project Number: EXE-82632 Page 3of28
Calculation 2014-04466 Revision 0 AMOUNT OF DEBRIS IN STRAINER WATER SAMPLES Page 04 of 028 Tables 1 & 2 summarize the gravimetric determination of the total mass in the submitted water samples. The total volume of the submitted water samples (ranged from 450 to 480 mL) was used for these measurements to maximize the test's sensitivity. It should be noted that the number of filter sets per sample varied from 1 to 8 depending on the particulate density. All the Test 6 samples and Nos. 13-30 Test 3 samples were weighed on single sets of filters. Test 3 Nos. 7-12 was weighed on 2 filter sets, Nos. 5 & 6 used 3, No. 4 used 4, No. 3 used 5, No. 2 used 7 and Test 3 No. 1 used 8 filter sets. This sub sampling was performed to provide an opportunity for subsequent visual particle counting.
Time Number 16:30:00 1
16:32:30 2
16:35:00 3
16:37:30 4
16:40:00 5
16:42:30 6
16:45:00 7
16:47:30 8
16:50:00 9
16:52:30 10 16:55:00 11 16:57:30 12 17:00:00 13 17:02:30 14 17:05:00 15 Table 1 Test 6, November 15, 2005 Solids Time mWL 9
17:07:30 37 17:10:00 12 17:12:30 36 17:15:00 6
17:17:30 13 17:20:00 7
17:22:30 6
17:25:00 4
17:27:30 5
17:30:00 4
17:32:30 2
17:35:00 2
17:37:30
<1 17:40:00 1
17:42:30 Number Solids mg/L 16
<1 17 2
18 3
19 4
20 4
21 4
22 6
23 4
24 4
25 5
26 5
27 5
28 4
29 5
30 5
Project Number: EXE-82632 Page 4 of 28
Calculation 2014-04466 Revision O Time 8:45:00 8:50:00 8:55:00 9:00:00 9:05:00 NA 9:15:00 9:20:00 9:25:00 9:30:00 9:35:00 9:40:00 9:45:00 9:50:00 9:55:00 Number 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 Table 2 Test 3, November 17, 2005 Solids Time mWL 852 10:00:00 356 10:05:00 262 10:10:00 137 10:15:00 84 10:20:00 65 10:25:00 53 10:30:00 39 10:35:00 28 10:40:00 21 10:45:00 19 10:50:00 23 10:55:00 17 11:00:00 14 11:05:00 12 11:10:00 Page 05 of 028 Number Solids m~/L 16 10 17 7
18 5
19 6
20 4
21 5
22 2
23 3
24 2
25 1
26 1
27 3
28 4
29 1
30
<1 CALCULATION OF MASS OF FIBERGLASS FIBERS IN TEST 6 SAMPLES Based on the reported values in Table 1, it was agreed to calculate the mass of fiberglass fibers in Samples 1, 2, 3, 5, 8, 11 and 14 from Test 6.
Determination of Fiberglass Fiber Diameter Fifteen random fibers were measured (from filters 6-8, 6-11, & 6-14) on the scanning electron microscope (SEM) for their diameters. The diameters ranged from 4.99 to 13.l microns, with an average diameter of 8.45 microns. There were also some fibers coated with a zinc crystalline compound. This phenomenon was only on the fibers from the actual test samples. The sample of fiberglass used in Tests 3 and 6 did not have the zinc coating.
The following are samples of photographs taken on the SEM of various fibers (see Photographs 1-5 and Spectrum 1 & 2). The average diameter of 8.45 microns and maximum diameter of 13.1 were both used to calculate the estimated mass of fiberglass present.
Project Number: EXE-82632 Page 5of28
Calculation 2014-04466 Revision O Attachment O Counting and Measuring Fiberglass Fibers Page 06 of 028 The counting and measuring of the fiberglass fibers was performed with a stereomicroscope at 11 OX.
One hundred percent of the fibers were counted for all the selected Set 6 samples except for Sample
- 1. For Sample 1 the uniform fiber distribution and density permitted that random fields of views could be used. The fibers were long rods, varying from straight to curved. Individual fibers lengths were measured. Many fibers bundled (typically bundles of 2 to 5 fibers). In these cases an effort was made to measure each fiber of the bundle. When the fibers were curved the lengths were a best estimate.
It should be noted that there were many more non-fibrous particles than the fiberglass.
Photograph 6 is of a graticle at the 11 OX magnification. Each division is 10 microns longs. The fibers counted ranged from 100 to greater than 21,000 microns in length, but were generally in the 100 to 1000 micron range.
Calculation of the Estimated Mass of Fiberglass Fibers in Test 6 Samples Table 3 summarizes the calculated mg/L density based on the provided fiberglass density (159 # I ft3), the measured fiber lengths, and the average fiber diameter or the maximum fiber diameter. Test 6 was performed on 11/15/2005.
In performing this type of testing various errors are possible. There is an uncertainty due to the variability of the fiberglass fiber's diameter. Because of this the mass calculation based on the mean and maximum fiber diameter was provided. There are also inaccuracies in determining fiber lengths due to the non-linear nature of many of the fibers, and miss-counting fibers due to that are hidden under other solids. There is a potential of missing or double counting fibers as the filter surface is scanned.
Table 3-Calculated Mass from Estimated Fiber Volume Measurements Test# 6 (11-15-05) 6-1 6-2 6-3 6-5 6-8 6-11 6-14 Time 1630 1632:30 1635 1640 1647:30 1655 1702:30
- of Fibers Counted 98*
1158 261 233 88 93 35 mg/L Fiberglass, 1.0 0.71 0.14 0.13 0.06 0.06 0.01 using average diameter mg/L Fiberglass, 2.5 1.7 0.34 0.31 0.14 0.13 0.05 using maximum diameter Total Suspended Solids 9
37 12 6
6 4
<1 from gravimetric (9.1)
(36.7)
(11.6)
(5.8)
(5.5)
(3.6)
(0.4) measurements, mg/L
- Because of uniform distribution and high fiber density, only ten areas of view (approximately one thirtieth of the total filter area) were counted. The factor of 29.7 was then used to calculate the fiber concentration.
Project Number: EXE-82632 Page 6 of 28
Calculation 2014-04466 Revision O Page 07 of 028 PHOTOGRAPHS OF FEED STOCK MATERIAL and FILTERS Fields of view of selected Test 6 and all Test 3 filters were taken.
Photographs 7 to 22 are of the Test 6 samples that were counted in Table 3. All Photographs were taken at 11 OX. What should be noted in these pictures is that with the exception of Sample 6-1, there are many more non-fibrous particles present than the fiberglass fibers.
Photographs 23 to 26 were taken at 1 lOX of the feedstock that was used for Test 3. The feedstock was fiberglass, pieces of glass, zinc powder (IOZ) and stone flour.
Photographs 27 through 89 were taken to document the material collected on the filters for Test 3.
There are photographs at both 18 and 110 X of each filter.
Data was provided to Mr. Davenport as it became available.
Testing was performed with standards and/or equipment that have accuracies traceable to nationally recognized standards or to physical constants, by qualified personnel, and in accordance with the Exelon PowerLabs Quality Assurance Program revision 17 dated 08/30/2005.
Technician(s): W. Treasurer Prepared by:
(signed original in file)
Approved by:
(signed original in file)
Title xx/xx/2005 cc:
J. Panici, Mod Design, Braidwood K. Dhaese, Mod Design, Byron.
I. Garza, Sargent Lundy B. Davenport, Mechanical/Structural Engineering, Cantera Project Number: EXE-82632 Page 7 of 28
Calculation 2014-04466 Revision O
- 1 i
u
- .OJO Page 08 of 028 Fiber Diameter Characterization Photograph 1 Fiberglass Feedstock used in Test 6.
The diameters varied from 5 to almost 10 microns. No zinc deposition was seen. The length to width ratio was in excess of 10:1.
Spectrum 1 Typical EDXA spectrum of fiberglass; it is primarily silicon with lesser amounts of sodium, calcium, oxygen, aluminum, magnesium and potassium. There is a small gold peak because the fibers were gold-coated as part of the SEM re aration.
Photograph 2 Some fibers from 6-11 Project Number: EXE-82632 Page 8 of28
Calculation 2014-04466 Revision o Attachment O Page 09 of 028 Photograph 3 More fibers from 6-11, note that they are joined (bundled) along the axis Photograph 4 Close-up of a fiber that has been coated with a zinc compound from 6-11 Project Number: EXE-82632 Page 9of28
Calculation 2014-04466 Revision O u*n Z11
- .o:io XJlt4lP,~ 1:1-?*.>
zn Ca Attachment O Page 010 of 028 10.:i90 Photograph 5 Coated fiber showing fiberglass core and zinc coating Spectrum 2 EDXA of the zinc coating on the fiber Photograph 6 This is a photograph of a graticle scale at approximately 110 X.
Each division is 10 microns; the entire length is 1000 micron.
Project Number: EXE-82632 Page 10 of 28
Calculation 2014-04466 Revision 0 Attachment O Page 011 of 028 Photographs of the Filters at llOX Photograph 7 Filter 6-1, View 1 Photograph 8 Filter 6-1, View 2
, Photograph 9 Filter 6-1, View 3 Project Number: EXE-82632 Page 11of28
Calculation 2014-04466 Revision o Page 012 of 028 Photograph 10 6-2, View 1 Photograph 11 6-2, View 2 Photograph 12 6-2, View 3 Project Number: EXE-82632 Page 12 of 28
Calculation 2014-04466 Revision O Page 013 of 028 J Photograph 13 1 Filter 6-3, View 1 Photograph 14 Filter 6-3, View 2 Photograph 15 Filter 6-5, View 1 Project Number: EXE-82632 Page 13 of 28
Calculation 2014-04466 Revision O
- *. l""'",
.~
~
- . f:
Page 014 of 028
,,.- - e -.
.~
Photograph 16 Filter 6-5, View 2
,, Photograph 17 Filter 6-5, View 3
~ "*
Photograph 18
- Filter 6-8, View 1 Project Number: EXE-82632 Page 14 of 28
Calculation 2014-04466 Revision 0 Attachment O
._F *t# **~*
~.....
- l>
Page 015 of 028 Photograph 19 1 Filter 6-8, View 2 Photograph 20
' Filter 6-11, View 1 Photograph 21 Filter 6-11, View 2 Project Number: EXE-82632 Page 15 of 28
Calculation 2014-04466 Revision O Attachment O Photograph 22 Filter 6-14, View 1 Photographs of the Feed Stock Materials at llOX Page 016 of 028 The following are photographs of the materials used for Test 3 taken with the stereomicroscope at llOX.
Photograph 23 Fiberglass Project Number: EXE-82632 Page 16 of 28
Calculation 2014-04466 Revision 0 Attachment O Page 017 of 028 Photograph 24 Glass, Much of the glass used were larger fragments than this one.
Photograph 25 Zinc Powder, IOZ Photograph 26 Stone Flour Project Number: EXE-82632 Page 17 of 28
Calculation 2014-04466 Revision o Page 018 of 028 Photographs from Test 3 mm Scale, at 18X, each division is 1000 microns (1 mm) 3-2, at 18X Photo ra h 31 Graticle scale at approximately 110 X.
Each division is 10 microns; the entire length is 1000 micron.
3-2, at llOX Photo ra h 32 Project Number: EXE-82632 Page 18 of 28
Calculation 2014-04466 Revision O 3-5, at 18X Photo ra h 37 Page 019 of 028 3-5, at llOX Photo ra h 38 Project Number: EXE-82632 Page 19 of 28
Calculation 2014-04466 Revision O 3-7, at 18X Photo ra h 41 3-8, at 18X Photo ra h 43 Attachment O Page 020 of 028 3-7, at llOX 3-8, at llOX Photo ra h 44 Project Number: EXE-82632 Page 20 of 28
Calculation 2014-04466 Revision O
- 5T~ :~*:.r.~:=:~[*::~~ ~*F~:*.:~:**:.:
A,'..
Photo ra h47..
3-11, at 18X Photo ra h 49 Page 021 of 028 3-11, at llOX Photo ra h 50 Project Number: EXE-82632 Page 21 of 28
Calculation 2014-04466 Revision 0 3-14, at 18X Photo ra h 55 Attachment O Page 022 of 028 3-14, at llOX Photo ra h 56 Project Number: EXE-82632 Page 22 of 28
Calculation 2014-04466 Revision 0 3-17, at 18X Photo ra h 61 Page 023 of 028 3-17, at llOX Photo ra h 62 Project Number: EXE-82632 Page 23of28
Calculation 2014-04466 Revision O 3-20, at 18X Photo ra h 67 Page 024 of 028 3-20, at llOX Photo ra h 68 Project Number: EXE-82632 Page 24 of 28
Calculation 2014-04466 Revision 0 3-23, at 18X Photo ra h 73 Attachment O Page 025 of 028 3-23, at llOX Photo ra h 74 Project Number: EXE-82632 Page 25 of 28
Calculation 2014-04466 Revision 0 3-26, at 18X Photo ra h 79 Page 026 of 028 3-26, at llOX Photo ra h 80 Project Number: EXE-82632 Page 26of28
Calculation 2014-04466 Revision O 3-29, at 18X Photo ra h 85 Attachment O Page 027 of 028 3-29, at llOX Photo ra h 86 Project Number: EXE-82632 Page 27of28
Calculation 2014-04466 Revision O 3-30, at 18X Photo ra h 88 Page 028 of 028 3-30, at llOX Photo ra h 89 Project Number: EXE-82632 Page 28of28
RS-16-081 April 15, 2016 10 CFR 50.54(f)
U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Braidwood Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457 Byron Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455 Revision to Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)
References:
(1)
Letter from D. M. Gullatt (Exelon Generation Company, LLC) to US NRC, "Plant-Specific Path and Schedule for Resolution of Generic Letter 2004-02,"
dated May 14, 2013 (2)
Letter from S. Bahadur (NRC) to W. A. Nowinowski (PWR Owners Group),
"Final Safety Evaluation for Pressurized Water Reactor Owners Group Topical Report WCAP-16793-NP, Revision 2, 'Evaluation of Long-Term Cooling Considering Particulate Fibrous and Chemical Debris in the Recirculating Fluid,"' dated April 8, 2013 (3)
Letter from D. M. Gullatt (Exelon Generation Company, LLC) to US NRC, "Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)," dated October 30, 2015 In Reference 1, Exelon Generation Company, LLC (EGC) stated that the only remaining open issue related to the resolution of GSl-191 was in-vessel downstream effects; and presented a resolution plan to close this issue. In-vessel downstream effects refers to post-accident debris in the recirculated water in containment, bypassing the recirculation sump strainers, and accumulating at the bottom of the fuel assemblies, having potential to reduce cooling flow to the core and degrading long term core cooling.
As noted in Reference 1, to address in-vessel downstream effects, Braidwood Station and Byron Station would use the acceptance criteria of 15 grams of fiber per fuel assembly specified in WCAP-16793-NP Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid." WCAP-16793 documents the results of industry debris head loss testing on a typical Westinghouse fuel assembly and sets acceptance criteria for debris loading to ensure long term core cooling is maintained.
April 15, 2015 U.S. Nuclear Regulatory Commission Page2 EGC committed to completing the resolution plan by documenting the quantity of fibrous debris that reaches the sump strainers; and verifying compliance with the limitations and conditions specified in the NRC Safety Evaluation (Reference 2) associated with WCAP-16793-NP Revision 2. This information was provided to the NRC in Reference 3.
During the subsequent review of Reference 3, the NRC inquired into the basis for the fiber bypass value used to determine the in-vessel fiber loading (i.e., grams of fiber per fuel assembly). EGC explained that the fiber bypass value was based on the Byron and Braidwood Stations' specific testing that utilized grab samples to determine strainer bypass. Subsequently, due to questions regarding the reliability of this method, EGC elected to utilize a different method to determine a new design basis fiber bypass fraction for Byron and Braidwood Stations.
Based on the similarities in strainer design, debris load, and penetration velocity between Byron, Braidwood, Salem and Palo Verde Stations; bypass testing data for Salem and Palo Verde Stations were used to determine a revised conservative bypass fraction for Byron and Braidwood Stations of 30%. The in-vessel fiber loading was calculated to be 11.9 grams/fuel assembly using a 30% bypass fraction and a transport fraction to the strainer of 75%, meeting the acceptance criteria of 15 grams/fuel assembly specified in WCAP-16793-NP Revision 2. The details of the methodology used to calculate the in-vessel fiber loading are provided in Attachment A, "Fiber Bypass Fraction and Grams of Fiber per Fuel Assembly," of Attachment 1, Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 1, "Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP." Note that attached Design Analysis 2014-04466, Revision 1, supersedes Design Analysis 2014-04466, Revision 0, submitted with Reference 3, in its entirety.
If you have any questions or require additional information regarding this submittal, please contact Joseph A. Bauer at (630) 657-2804.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 15th day of April 2016.
Respectfully, David M. Gullett Manager - Licensing Exelon Generation Company, LLC
Attachment:
Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 1, Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP cc:
USNRC Region Ill, Regional Administrator USN RC Senior Resident Inspector, Braidwood Station USNRC Senior Resident Inspector, Byron Station
ATTACHMENT 1 Braidwood Station and Byron Station Design Analysis 2014-04466, Revision 1 Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSl)-191)
Exelon~
Ce-AA40940U1 Revision 8 Design Analysis Analysis No.: 1 Nuclear ATfA~MeNT1 Design Analysis Major Revision Cover She-1 Pagel Last Page No. 8 15, Attachment D! f)a(JQ 028 2014-04466 Revision:*
1 Major 181 MlnorO
Title:
3 Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793--NP ECIECFl No.: 4 405352 (Braidwood), 405357(Byron)
Revision: 5 0,0
- station(s)i 7
- Byron/Braidwood Qomponent(a):
Unit No.: 8 1 and2 NIA Discipline: 9 MEDC Descrip. Code/Keyword: 10 M03 Safety/QA Class: 11 SA System Code: 12 SI Structure: 13 N/A CONTAC::>~ ~rm:t=EllEMCES 15
, Document No.:
Fromrro Document No.:
FromfTo WCAP-16793-NP From CN*SEE-1-07-38 From CN..CRA* 10-54 From BRW-06-0016-M From WCAP-17057 From BYAOS-029 From Js this Design Analysis Safeguards ~fot"maCion't&
YesQ No.21 If yes, see SY-AA-101-106 Does this Dfffgn Aril(pfS. contilfi'I Unverified AHumptfoJQl?17
~""'"~-
YeeQ tlo fgJ If~. ATl/AA#:
This o **.,.,.yaitt$UPE.RCEDES:14 NIA in its~~
. Qesc:tiptlOn ofRevisi011'(1lst chat'lged pages When ar pages at original analysis were notchang9(1}:...
Revlslon 1 changes the method for calculating the fiber bypass fraction. The fiber load is calculated to be below the limit of 15 glfuel assembly. Revision 1 also references the results of Revision 3 to design analysis CN-SEE-1-07-38.
Preparer: 1111 H.Kopk~
See Satfl!'flt, & lttnciY'Document
~-Prfrtt~
,Signtlam*
Data M81hod of Review: 21 'netaled Riivrew a Al...
¢.1oufatioits(attached)0 Testing t:'J ReVhiwer:.,.
E. Decristofaro, S. Paartberg See Sargent & Lundy Document Print Name Sign Name
.Dl1tlt RBvlew Notes: a:i Independent review 1&1 Peer review D
(~Ellltft'll!!~ung; E"'8maf Approver:;. 20 A.Peterson See Sargent & Lundy Document Print Name Sign Name Dale See Owner Exetan ReViewarr 25 See Owner Review Record, Review Record, page II See Owner Aevlew'Rec;ottf, p~e II
.Paga II
- ~*
., ~rlnt Name Signt.lama
- oate lntt.-CJ,mt31117Party ~evifW Reqd?'26 Yes[J Nol fl_._
f.f!N/)bl'
~011 Approver: 21 J.Cunzeman PJ:fr}t~
(
'/
llP'ililame
~*
Calculation #2014-04466 Revision 1 Page II Exelon Owner Review Record Design Analysis: 2014-044§6 Revision 1 Design Analysis
Title:
Assessment of the NRC:: Safety Evajµation Limitations and Conditions Associated with WC::AP-16793-NP 1
Exelon Reviewers:
Giovanni Panici <Braid wood)
Print Name Kevin Dhaese <Byron)
Print Name
~Name Sign Name
'-1. 14. ~6 Date
DESIGN ANALYSIS TABLE OF CONTENTS Analysis No. 2014-04466 Rev. No. 1 Page No. HA SECTION:
PAGE NO.
SUB-PAGE NO.
Design Analysis Cover Sheet I
Owner Acceptance Review Record II Table of Contents llA Owner Acceptance Review (Not included in this document as these pages are proprietary to Exelon Generation llB II B, !IC, llD Company)
External Analysis 2014-04466 Revision 1 1
1-15 Attachment A - Fiber Bypass Fraction and Grams of Fiber per A1 A1-A.2-12 Fuel Assembly Calculation Attachment B - Available Driving Head Calculation B1 B1-B3 Attachment C - Maximum Flow Rate per Fuel Assembly C1 C1 Calculation Attachment D - Exelon Power lab Report-Sump Strainer D1 01-028 Particle Loading.
Lundy***
DESIGN CONTROL
SUMMARY
CLIENT:
Exelon UNIT:
1&2 PAGE NO.:
l PROJECT NAME:
Byron/Braidwood S&L NUCLEAR QA PROGRAM PROJECT NO.:
11332-194 APPLICABLE 181 YES 0 NO CALC. NO.. :
2014-04466 SAFETY RELATED 181 YES 0 NO TITLE:
Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-16793-NP EQUIPMENT NO.:
IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD Initial issue (47 pages). This calculation supplements Calculation Note INPUTS/ ASSUMPTIONS CN-SEE-I-07-38.
181 VERIFIED 0
UNVERIFIED REVIEW METHOD:
Detailed Review REV.:
0 STATUS:
181 APPROVED 0 SUPERSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
07/14/2015 PREPARER:
Eric R. DeCristofaro (Signature on file)
DATE:
12/05/2014 REVIEWER:
Matthew M. Ross (Signature on file)
DATE:
12/05/2014 REVIEWER:
Helmut R. Kopke (Signature on file)
DATE:
12/05/2014 (Client Comment Incorporation)
APPROVER:
Robert J. Peterson (Signature on file)
DATE:
07/1412015 IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD Calculation revised to update the design basis fiber bypass, and hence the in-vessel fiber loading (grams of fiber per fuel assembly or g/FA).
Changes to main body tracked with revision bars. Attachment A revised in Its entirety. Attachments B, C, and Dare INPUTS/ ASSUMPTIONS unchanged.
181 VERIFIED 88 Total Pages.
0 UNVERIFIED REVIEW METHOD:
Detailed Review REV.:
1 STATUS:
.MAPPROVED 0 SUPEflSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
'1~l5.-Lb PREPARER:
Helmut R. Kopke 71#£.!t--
DATE: q._-t3-2..0l6 REVIEWER:
Eric R. DeCristofaro c
~,/,/.., _.-
DATE: !:J.- IS -;},p/6 REVIEWER:
Stephen J. Paarlberg (2nd Round OAR Comments Only)
~_:; --
1/
DATE: *-W. I b APPROVER:
Robert J. Peterson M\\h-:..1 tL~.~
{./
DATE:
_ M IDENTIFICATION OF PAGES ADDED/REVISED/SUPERSEDEDNOIDED & REVIEW METHOD INPUTS/ ASSUMPTIONS 0
VERIFIED 0
UNVERIFIED REVIEW METHOD:
REV.:
STATUS:
0APPROVED 0 SUPERSEDED BY CALCULATION NO.
OVOID DATE FOR REV.:
PREPARER:
DATE:
REVIEWER:
DATE:
APPROVER:
DATE:
Calculation 2014-04466 Revision 1 Table of Contents Page 2of15 Page Cover Page........................................................................................................................... 1 Table of Contents................................................................................................................. 2 1.0 Background and Purpose.............................................................................................. 3 2.0 References..................................................................................................................... 4 3.0 Limitations and Conditions to the use ofWCAP-16793-NP, Rev. 2........................... 7 4.0 Conclusions................................................................................................................. 15
- of Pages Attachment A: Fiber Bypass Fraction and Grams of Fiber Per Fuel Assembly Calculation................................................................................................ 41 Attachment B: Available Driving Head...............................................................................3 Attachment C: Maximum Flow Rate Per Fuel Assembly................................................... 1 Attachment D: Exelon Power Labs Report (Ref. 2.19)..................................................... 28 List of Affected Sections Main body (all pages)
Attachment A (all pages)
Attachment B Attachment C Attachment D Revision 1 Revision 1 Revision 0 Revision 0 Revision 0
Calculation 2014-04466 Revision 1
1.0 BACKGROUND
AND PURPOSE Page 3 of15 The current Byron and Braidwood in-vessel effects analysis is documented in Westinghouse Calculation Note CN-SEE-1-07-38, Revision 3, "LOCADM Analysis." This calculation is based on Revision 2 of WCAP-16793-NP, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid." The calculation presents the results of the LOCADM analysis (maximum deposition thickness and fuel cladding temperature),
but does not address the limitations and conditions presented in Section 4.0 of the NRC Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2. Also, Appendix B of Calculation Note CN-SEE-1-07-38 contains an assessment of fuel blockage due to fibrous debris which is "no longer applicable" per the verbiage in the appendix.
The purpose of this calculation is to addresses the fourteen limitations and conditions presented in Section 4.0 of the NRC Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2, for Byron and Braidwood. These limitations and conditions are to be addressed by licensees as part of their response to the NRC to in-vessel long term core cooling concerns. As a part of addressing these limitations the following additional information is determined:
Attachment A calculates the fiber bypass fraction and grams of fiber per fuel assembly.
Attachment B calculates the available driving head.
Attachment C calculates the maximum flow rate per fuel assembly.
Revision 1 of this calculation updates the method used to determine the design basis fiber bypass quantity. The revised fiber bypass results in a change to the in-vessel fiber quantity (grams of fiber per fuel assembly).
Calculation 2014-04466 Revision 1
2.0 REFERENCES
Page 4of15 2.1 Safety Evaluation by the Office of Nuclear Reactor Regulation to WCAP-16793-NP, Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," October 2011 (ADAMS Accession No. ML12084A154). Transmitted via Jetter from Sher Bahadur (NRC) to Anthony Nowinowski (PWR Owners Group), on April 8, 2013, (ADAMS Accession No. ML13084A152)).
2.2 Drawing 113E977 2.2.1 Braidwood Units 1 & 2, Sheet 1, Rev. 5, "4 Loop Reactor Vessel Units 1 &
2."
2.2.2 Byron Units 1 & 2, Sheet 1, Rev. 5, "4-Loop 173.000 I.D. Reactor Vessel."
2.3 Drawing M-196 2.3.1 Byron Unit 1, Sheet 1, Rev. M, "Reactor Coolant Loop Piping Arrangement and Weld Details."
2.3.2 Byron Unit 2, Sheet 2, Rev H, "Reactor Coolant Loop Piping Arrangement" 2.3.3 Braidwood Unit 1, Sheet 1, Rev. N, "Reactor Coolant Loop Piping Arrangement Unit 1" 2.3.4 Braidwood Unit 2, Sheet 2, Rev. H, "Reactor Coolant Loop Piping Arrangement" 2.4 Calculation Note Number CN-CRA-10-54, Rev. 2 (Braidwood), Rev. 1 (Byron),
"Byron/Braidwood Units 1 and 2 LOCA Long-Term M&E and Containment Re-Analysis for IR Issues Identified in 2010."
2.5 ASME Steam Tables, 1967.
2.6 WCAP-17057-P, Rev. 1, "GSI-191 Fuel Assembly Test Report for PWROG."
2.7 Pressurized Water Reactor Owners Group (PWROG), Topical Report (TR) WCAP-16793-NP, Rev. 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," Dated July, 2013.
2.8 Arey, M., PWROG letter to Document Control Desk, NRC, "PWROG Response to Request for Additional Information Regarding Topical Report WCAP-16793-NP, Revision 1, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," (PA-SEE-0312)," August 9, 2010 (ADAMS Accession No. ML102230031).
2.9 Byron/Braidwood UFSAR, Revision 15, Tables 4.1-1 and 5.4-5.
2.10 Steam Generator Support Pad Elevation 2.10.l Braidwood Unit 2 Drawing 2SG-Ol, Rev. A, "Spec L-2907, Inspection Identification Drawing For Inservice Inspection of Steam Generator No.
2RC01BA Loop #1, Unit 2."
2.10.2 Braidwood Unit 2 Drawing 2SG-02, Rev. A, "Spec L-2907, Inspection Identification Dwg. For lnservice Inspection of Steam Generator No.
2RC01BB Loop #2, Unit 2."
2.10.3 Braidwood Unit 2 Drawing 2SG-03, Rev. A, "Spec L-2907, Inspection Identification Dwg. For lnservice Inspection of Steam Generator No.
2RC01BC Loop #3, Unit 2."
2.10.4 Braidwood Unit 2 Drawing 2SG-04, Rev. B, "Spec L-2907, Inspection Identification Dwg. For Inservice Inspection of Steam Generator No.
Calculation 2014-04466 Revision 1 2RC01BD Loop #4, Unit 2."
Page S of lS 2.10.S Byron Unit 2 Drawing 2SG-l-ISI, Rev. B, Sheet 1, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BA."
2.10.6 Byron Unit 2 Drawing 2SG-1-ISI, Rev. A, Sheet 3, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BB."
2.10.7 Byron Unit 2 Drawing 2SG-l-ISI, Rev. C, Sheet 2, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BC."
2.10.8 Byron Unit 2 Drawing 2SG-l-ISI, Rev. A, Sheet 4, "Inspection Identification Dwg. For Inservice Inspection for Steam Generator No.
2RC01BD."
2.10.9 Byron and Braidwood Unit 2, "Vertical Steam Generator Instructions,"
January 1980.
2.10.10 Drawing 7720E001, Rev. 6, "Steam Generator Arrangement" 2.11 Calculation No. BYR06-029 I BRW-06-0016-M, Rev. S, "SI/RHR/CS/CV System Hydraulic Analysis in Support of GSI-191." Byron currently uses Rev. S, and Braidwood uses Revs.Sand SA. The information used herein is from Rev.Sand is not impacted by Rev. SA.
2.12 Braidwood EC 38960S, Rev. 1, "Westinghouse 17Xl 7 OFA Fuel Changes; Robust P-Grid and Standardized Debris Filter Bottom Nozzle."
2.13 Byron EC 388707, Rev. 0, "Westinghouse 17Xl 7 OFA Fuel Changes; Robust P-Grid and Standardized Debris Filter Bottom Nozzle."
2.14 CCI Test Specification Q.003.84 748, Revision 3, "Containment Sump Strainer Replacement: Large Size Filter Performance Test."
2.lS TODI NF12002S7, Rev. 0, "Byron Unit 2 Cycle 18 Non-MUR Reload Design Initialization."
2.16 TODI NFll 0040S, Rev. 1, "Byron Unit 1 Cycle 19 Reload Design Initialization."
2.17 TODI NF1300006, Rev 0, "Braidwood Unit 1 Cycle 18 Reload Design Initialization" 2.18 TODI NF1300169, Rev. 0, "Braidwood Unit 2 Cycle 18 Reload Design Initialization."
2.19 Exelon Power Labs Report, "Sump Strainer Particle Loading," 02/01/2006. (see Attachment D) 2.20 CCI Report 680/41134, Rev. 3, "Large Size Filter Performance Test."
2.21 Letter from J. Butler (NEI) to S. Bailey (NRC),
Subject:
Fibrous Debris Preparation Procedure for ECCS Recirculation Sump Strainer Testing, Revision 1, dated January 30, 2012 (ADAMS Accession No. ML1204810S2), including Attachment entitled, "ZOI Fibrous Debris Preparation: Processing, Storage and Handling,"
Revision 1, January 2012, (ADAMS Accession No. ML1204810S7).
2.22 Calculation Note Number CN-SEE-1-07-38, Rev. 3, "LOCADM Analysis for Byron/Braidwood Units 1 and 2."
2.23 Calculation No. BRW-OS-OOS9-M I BYROS-041, Rev. 2, "GSl-191 Post-LOCA Debris Generation."
Calculation 2014-04466 Revision 1 Page 6of15 2.24 PSEG Letter No. LR-N13-0091 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Responses to NRC Questions Regarding Salem Bypass Testing, dated April 22, 2013. ADAMS Accession No. ML13114A048.
2.25 NRC Letter (John G. Lamb) to PSEG (Thomas Joyce),
Subject:
Salem Nuclear Generating Station, Units 1 and 2 - Close-out of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors" (TAC Nos. MC4712 and MC4713),
dated April 30, 2014. ADAMS Accession No. ML14113A202.
2.26 U.S. Nuclear Regulatory Commission Staff Review of the Documentation Provided by PSEG Nuclear, LLC, for Salem Nuclear Generating Station, Units 1 and 2, Concerning Resolution of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors." ADAMS Accession No. ML14113A221.
The following Byron/Braidwood drawing and calculation References were verified as current in PASSPORT on 2/10/2016: 2.2, 2.3, 2.4, 2.10, 2.11, and 2.23.
Calculation 2014-04466 Revision 1 Page 7of15 3.0 Limitations and Conditions to the use ofWCAP-16793-NP, Rev. 2 Section 4.0 of the SER for WCAP-16793 [Ref. 2.1] lists fourteen limitations and conditions that are to be addressed by licensees as part of their response to in-vessel long term core cooling concerns. These limitations are addressed individually in Sections 3.1 through 3.14 of this calculation.
3.1 Limitation 1 Limitation 1 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should corifirm that their plants are covered by the PWROG sponsored fuel assembly tests by confirming that the plant available hot-leg break driving head is equal to or greater than that determined as limiting in the proprietary fuel assembly tests and that flow rate is bounded by the testing. Licensees should validate that the fuel types and inlet filters in use at the plant are covered by the test program (with the exception of LTAs).
Licensees should limit the amount of fibrous debris reaching the fuel inlet to that stated in Section JO of the WCAP (I 5 grams per fuel assembly for a hot-leg break scenario).
Alternately, licensees may perform plant specific testing and/or evaluations to increase the debris limits on a site-specific basis. The available driving head should be calculated based on the core exit void fraction and loop flow resistance values contained in their plant design basis calculations, considering clean loop flow resistance and a range of break locations.
Calculations of available driving head should account for the potential for voiding in the steam generator tubes. These tests shall evaluate the effects of increased fiber on flow to the core, and precipitation of boron during a postulated cold-leg break, and the effect ofplfratios below 1:1. The NRC staff will review plant specific evaluations, including hot-and cold-leg break scenarios, to ensure that acceptable justification for higher debris limits is provided. (Sections 3.1.2 (c), 3.1.2 (e), 3.3.1, 3.4.2, 3.8, 3.9 and 3.10 of this SE)."
It is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. In addition, the available hot-leg break driving head is calculated in Attachment B to be between 13.2 and 14.2 psi for Byron and Braidwood Units 1 and 2. This is much greater than the maximum measured debris head loss during PWROG fuel assembly testing of 2.7 psi [Bullet 1 on page 6-51 of Ref. 2.6].
The maximum flow rate per fuel assembly during cold-leg injection at Byron and Braidwood is 43.6 gpm (see Attachment C). This flow rate is bounded by the maximum flow rate of 44.7 gpm per fuel assembly used in the Westinghouse and Areva testing [Table G-2 and G-3 of Ref. 2.7]. Thus, the hot-leg break available
Calculation 2014-04466 Revision 1 Page 8of15 driving head is greater than the debris head loss measured during the fuel assembly blockage test which is the basis for the 15 gram per fuel assembly limit.
In addition, Byron/Braidwood has Westinghouse fuel with a Robust P-grid design
[Refs. 2.15, 2.16, 2.17 and 2.18]. The Robust P-grid design was evaluated in Braidwood EC 389605 [page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
Per the above discussion, Limitation 1 is met.
3.2 Limitation 2 Limitation 2 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Each licensee's GL 2004-02 submittal to the NRC should state the available driving head used in the evaluation of the hot-leg break scenario, the ECCS flow rates, and the results of the LOCADM calculations.
Licensees should provide the type(s) of fuel and inlet filters installed in their plants, as well as the amount of fiber (gram per fuel assembly) that reaches the core. (Section 3. 3.1 and 3.10 of this SE) "
The available hot-leg break driving head is calculated in Attachment B to be between 13.2 and 14.2 psi for Byron and Braidwood Units 1 and 2. This is much greater than the maximum measured debris head loss during PWROG fuel assembly testing of 2.7 psi [Bullet 1 on page 6-51 of Ref. 2.6]. The maximum flow rate per fuel assembly at Byron and Braidwood is 43.6 gpm (See Attachment C). This flow rate is bounded by the maximum flow rate of 44. 7 gpm per fuel assembly used in the Westinghouse and Areva testing [Table G-2 and G-3 of Ref. 2.7]. Thus, the hot-leg break available driving head at Byron I Braidwood is greater than the debris head loss measured during the fuel assembly blockage test which is the basis for the 15 gram per fuel assembly limit.
Byron/Braidwood has Westinghouse fuel with a Robust P-grid design [Refs. 2.15, 2.16, 2.17 and 2.18]. The Robust P-grid design was evaluated in Braidwood EC 389605 [page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris
Calculation 2014-04466 Revision 1 Page 9of15 Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
It is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. The results of the LOCADM calculations are provided in Calculation Note Number CN-SEE-I-07-38 [Ref. 2.22] and are repeated in Table 3.1.
T bl 3 1 LOCADM R I S a e. :
esu ts ummarv Parameter Value Acceptance Criteria Maximum Cladding Temperature
< 620°F
< 800°F Maximum Total Deposition Thickness
< 18 mil
< 50 mil Per the above discussion, Limitation 2 is met.
3.3 Limitation 3 Limitation 3 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Section 3.1.4.3 of the WCAP states that alternate flow paths in the RPV were not credited The section also states that plants may be able to credit alternate flow paths for demonstrating adequate LTCC. If a licensee chooses to take credit for alternate flow paths, such as core baffle plate holes, to justify greater than 15 grams of bypassed fiber per fuel assembly, the licensee should demonstrate, by testing or analysis, that the flow paths would be effective, that the flow holes will not become blocked with debris during a LOCA, that boron precipitation is considered, and that debris will not deposit in other locations after passing through the alternate flow path such that LTCC would be jeopardized (Sections 3.3.1 and 3.4.2 of this SE)"
Limitation 3 is met because no alternative flow paths through the core are credited.
3.4 Limitation 4 Limitation 4 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Sections 3.2 and 3.3 of the WCAP provide evaluations to show that even with large blockages at the core inlet, adequate flow will enter the core to maintain LTCC. The staff recognizes that these calculations show that significant head loss can occur while maintaining adequate flow. However, the analyses have not been correlated with debris amounts. Therefore, the analyses cannot be relied upon to demonstrate adequate LTCC. (Sections 3.3. 3 and 3.4 of this SE) "
Calculation 2014-04466 Revision 1 Page 10of15 Limitation 4 is met because it is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly. In addition, the evaluations provided in Sections 3.2 and 3.3 ofWCAP-16793 are not used.
3.5 Limitation 5 Limitation 5 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"In RAJ Response number 18 in Reference 13, the PWROG states that numerical analyses demonstrated that, even if a large blockage occurs, decay heat removal will continue. The NRC staff's position is that a plant must maintain its debris load within the limits defined by the testing (e.g.,
15 grams per assembly). Any debris amounts greater than those justified by generic testing in this WCAP must be justified on a plant-specific basis.
(Sections 3.4.2 and 3.10 of this SE)"
Limitation 5 is met because it is shown in Attachment A of this calculation that the quantity of fibrous debris that could bypass the ECCS screens and reach the core is less than 15 grams per fuel assembly.
3.6 Limitation 6 Limitation 6 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"The fibrous debris acceptance criteria contained in the WCAP may be applied to fuel designs evaluated in the WCAP. Because new or evolving fuel designs may have different inlet fittings or grid straps that could exhibit different debris capture characteristics, licensees should evaluate fuel design changes in accordance with 10 CFR 50.59 to ensure that new designs do not impact adequate long term core cooling following a LOCA.
(Section 3.4.2 of this SE)"
Limitation 6 is met because the Byron/Braidwood Westinghouse fuel with Robust P-grid design [Refs. 2.15, 2.16, 2.17, 2.18] is evaluated in Braidwood EC 389605
[page 14 of Ref. 2.12] and Byron EC 388707 [page 14 of Ref. 2.13] and found by Westinghouse to have similar debris mitigation effectiveness to the standard P-Grid design evaluated in WCAP-16793. In addition, per Braidwood EC 389605 [page 9 of Ref. 2.12] and Byron EC 388707 [page 9 of Ref. 2.13] changing from the current Debris Filter Bottom Nozzle (DFBN) to the Standardized Debris Filter Bottom Nozzle (SDFBN) has "no impact to the debris limits for the fuel assembly due to Generic Safety Issue 191 (GSI-191) Downstream Effects."
Calculation 2014-04466 Revision 1
- 3. 7 Limitation 7 Page 11 of15 Limitation 7 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Sections 2 and 4.3 of the WCAP establish 800 degrees Fahrenheit as the acceptance limit for fuel cladding temperature qfter the core has been re-flooded. The NRC staff accepts a cladding temperature limit of 800 degrees Fahrenheit as the long-term cooling acceptance basis for GSl-191 considerations. Each licensee's GL 2004-02 submittal to the NRC should state the peak cladding temperature predicted by the LOCADM analysis. If a licensee calculates a temperature that exceeds 800 degrees Fahrenheit, the licensee must submit data to justify the acceptability of the higher clad temperature. (Sections 3.2, 3.4.3, 3.4.4, and 3.10 of this SE)"
Limitation 7 is met since the LOCADM spreadsheet was used in the Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22] to show that the maximum fuel cladding temperature does not exceed 800 °F. The peak cladding temperature was found using the LOCADM spreadsheet to be less than 620°F [Ref. 2.22].
3.8 Limitation 8 Limitation 8 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"As described in the Limitations and Conditions for WCAP-16530-NP (ADAMS Accession No. ML073520891) (Reference 21), the aluminum release rate equation used in TR WCAP-16530-NP provides a reasonable fit to the total aluminum release for the 30-day ICET tests but under-predicts the aluminum concentrations during the initial active corrosion portion of the test. Actual corrosion of aluminum coupons during the ICET 1 test, which used sodium hydroxide (NaOH), appeared to occur in two stages; active corrosion for the first half of the test followed by passivation of the aluminum during the second half of the test. Therefore, while the 30-day fit to the ICET data is reasonable, the WCAP-16530-NP-A model under-predicts aluminum release by about a factor of two during the active corrosion phase of ICET 1. This is important since the incore LOCADM chemical deposition rates can be much greater during the initial period following a LOCA, if local conditions predict boiling. As stated in WCAP-16530-NP-A, to account for potentially greater amounts of aluminum during the initial days following a LOCA, a licensee 's LOCADM input should apply a factor of 2 increase to the WCAP-16530-NP-A spreadsheet predicted aluminum release, not to exceed the total amount of aluminum predicted by the WCAP-16530-NP-A spreadsheet for 30 days. In other words, the total amount of aluminum released equals that predicted by the WCAP-16530-NP-A spreadsheet, but the timing of the release is accelerated. Alternately, licensees may choose to use a different method for determining aluminum release but licensees should not use an aluminum
Calculation 2014-04466 Revision 1 Page 12of15 release rate equation that, when aqjusted to the ICET 1 pH, under-predicts the aluminum concentrations measured during the initial 15 days of ICET
- 1. (Section 3. 7 of this SE) "
Consistent with the procedure described in Limitation 8, a factor of 2 increase on the surface area of aluminum is used in this analysis (see Section 5.2.1 in Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22]). Therefore, Limitation 8 is met.
3.9 Limitation 9 Limitation 9 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Jn the response to NRC staff RA!s, the PWROG indicated that if plant-specific refinements are made to the WCAP LOCADM base model to reduce conservatisms, the user should demonstrate that the results still adequately bound chemical product generation. If a licensee uses plant-specific refinements to the WCAP-16530-NP-A base model that reduces the chemical source term considered in the downstream analysis, the licensee should provide a technical justification that demonstrates that the refined chemical source term adequately bounds chemical product generation.
This will provide the basis that the reactor vessel deposition calculations are also bounding. (Section 3. 7 of this SE)"
Limitation 9 is met since an unmodified version of the LOCADM spreadsheet was used in Calculation Note Number CN-SEE-1-07-38 [Ref. 2.22] to compute the maximum fuel cladding temperature and the total debris deposition on the fuel rods.
3.10 Limitation 10 Limitation 10 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"The WCAP states that the material with the highest insulating value that could deposit from post-LOCA coolant impurities would be sodium aluminum silicate. The WCAP recommends that a thermal conductivity of 0.11 BTUl(h-ft-°F) be used/or the sodium aluminum silicate scale and/or bounding calculations when there is uncertainty in the type of scale that may form. If plant-specific calculations use a less conservative thermal conductivity value for scale (i.e., greater than 0.11 BTU/(h-ft-°F)), the licensee should provide a technical justification for the plant-specific thermal conductivity value. This justification should demonstrate why it is not possible to form sodium aluminum silicate or other scales with thermal conductivities less than the selected value. (Section 3. 7 of this SE) "
Limitation 10 is met since an unmodified version of the LOCADM spreadsheet with the default thermal conductivity of 0.11 BTU I (h-ft-°F) was used in
Calculation 2014-04466 Revision 1 Page 13of15 Calculation Note Number CN-SEE-I-07-38 [Ref. 2.22] to compute the maximum fuel cladding temperature and the total debris deposition on the fuel rods.
3.11 Limitation 11 Limitation 11 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should demonstrate that the quantity of fibrous debris transported to the fael inlet is less than or equal to the fibrous debris limit specified in the proprietary fuel assembly test reports and approved by this SE. Fiber quantities in excess of 15 grams per fuel assembly must be justified by the licensee. Licensees may determine the quantity of debris that passes through their strainers by (1) performing strainer bypass testing using the plant strainer design, plant-specific debris loads, and plant-specific flow velocities, (2) relying on strainer bypass values developed through strainer bypass testing of the same vendor and same perforation size, prorated to the licensee's plant specific strainer area,*
approach velocity; debris types, and debris quantities, or (3) assuming that the entire quantity of fiber transported to the sump strainer passes through the sump strainer. The licensee's submittals should include the means used to determine the amount of debris that bypasses the ECCS strainer and the fiber loading expected, per fuel assembly, for the cold-leg and hot-leg break scenarios. Licensees of all operating PWRs should provide the debris loads, calculated on a fuel assembly basis, for both the hot-leg and cold-leg break cases in their GL 2004-02 responses. (Section 3.10 of this SE)"
At Byron/Braidwood the fibrous debris generated due to a cold-leg break is the same as for a hot-leg break since the only fiber from both breaks is 100% latent fiber
[Ref. 2.23]. The fiber bypass is determined using testing performed by CCI (the strainer vendor) for other utilities with a CCI strainer with the same perforation size as Byron/Braidwood, as described in Attachment A. The fiber calculated to bypass the strainers and reach the fuel assembly is 11.9 grams per fuel assembly (See Attachment A). This quantity is less than the WCAP-16793-NP acceptance criteria of 15 grams per fuel assembly and therefore Limitation 11 is met.
3.12 Limitation 12 Limitation 12 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Plants that can qualifY a higher fiber load based on the absence of chemical deposits should ensure that tests for their conditions determine limiting head losses using particulate and fiber loads that maximize the head loss with no chemical precipitates included in the tests. (Section 3.3.1 of this SE) Note that in this case, licensees must also evaluate the other considerations discussed in Item 1 above."
Calculation 2014-04466 Revision 1 Page 14of15 Limitation 12 is met because Byron/Braidwood does not utilize a fiber debris limit greater than 15 grams per fuel assembly (See Attachment A).
3.13 Limitation 13 Limitation 13 in Section 4.0 of the SER to WCAP-16793 is repeated below:
"Licensees should verifY that the size distribution of fibrous debris used in the fuel assembly testing referenced by their plant is representative of the size distribution of fibrous debris expected downstream of the plant's ECCS strainer(s). (Section 3.4.2. J of this SE) "
CCI Report Q.003.83 748 [Ref. 2.14] states the following about fiber preparation "The fibers used in the test should be identical (as far as practical) to that used at Byron/Braidwood Unit 1. The fibers will be decomposed by first cutting with a leaf shredder, manually tearing the shredded fibers into smaller pieces and then soaking the pieces in a water bucket. A water jet is used to separate the fiber in the bucket after it is shredded by the leaf shredder." This fiber preparation method is consistent with CCI's standard method which was found to be substantially consistent with NEI 's recommended fiber preparation procedure [Ref. 2.21].
The results of the Byron I Braidwood specific fiber bypass testing show that the fiber size distribution at Byron I Braidwood ranged from 0.1 mm to greater than 21 mm in length, but were generally in the 0.1 mm to 1 mm range [page 6 of Ref. 2.19]. This is consistent with the fiber size distribution in WCAP-16793-NP
[Ref. 2. 7] which is presented in the table below.
Table 3.2: Fiber B ass Size Cate o (a) 0-0.5 mm 0.5-1 mm
> 1 mm 67-87%
8-28%
0-15%
(a) From page G-8 ofWCAP-16793-NP, Revision 2 [Ref. 2.7]
Therefore, Limitation 13 is met.
Note: Although the NRC had concerns with the total fiber bypass quantity determined in the Byron/Braidwood specific tests due to the bypass quantity being based on grab samples, it is acceptable and common to use grab samples when determining downstream debris size distributions. The NRC accepted the use of grab samples for determining the downstream size distribution of fiber for another utility [Refs. 2.24, 2.25, and 2.26]. Therefore, the use of the Byron/Braidwood specific fiber bypass testing in the response to this limitation is acceptable.
3.14 Limitation 14 Limitation 14 in Section 4.0 of the SER to WCAP-16793 is repeated below:
Calculation 2014-04466 Revision 1 Page 15of15 "The "Margin Calculator," referenced in References 11 and 12, has not been submitted to the NRC under formal letter, and NRC staff has not performed a detailed review of the document. Therefore, NRC staff expects licensees to base their GL 2004-02 invessel effects evaluations on the information provided in the proprietary test reports and associated RAJ responses (References 8, 16, 17, 11 and 12), including the conditions and limitations stated in this SE, and existing plant design-basis calculations and analyses. "
Limitation 14 is met because the "Margin Calculator" is not used.
4.0 CONCLUSION
S Section 4.0 of the SER to WCAP-16793 lists fourteen limitations and conditions that are to be addressed by licensees as part of their response to in-vessel long term core cooling concerns. This calculation addresses each limitation and shows that Byron and Braidwood meet each limitation.
I
Calculation 2014-04466 Revision 1 Attachment A Page Al of Al 7 ATTACHMENT A: FIBER BYPASS FRACTION AND GRAMS OF FIBER PER FUEL ASSEMBLY CALCULATION Note: This attachment contains its own Reference section. Therefore, References in this attachment do not refer to the main body Reference section unless otherwise stated.
1.0 Background I Purpose In October 2015, Exelon submitted Revision 0 of this calculation (2014-04466) to the NRC as part of the closure documentation for GSI-191 [Ref. 16]. Subsequent to this submittal, the NRC inquired into the basis for the fiber bypass value used to determine the in-vessel fiber loading (grams of fiber per fuel assembly). Exelon explained that the fiber bypass value was based upon Byron/Braidwood specific testing that utilized grab samples to determine strainer bypass [Refs. 2.14, 2.19, and 2.20 of main body]. The NRC expressed concern with this method, as it has been established since the time of the Byron/Braidwood testing (2005) that the use of grab samples to determine fiber bypass fraction/quantity can be inaccurate. For this reason, Exelon elected to determine a new design basis fiber bypass fraction for Byron/Braidwood.
The purpose of this attachment is to document the design basis fiber bypass fraction and quantity as well as the resulting in-vessel fiber loading (grams of fiber per fuel assembly).
2.0 Methodology One of the primary reasons that the strainer fiber bypass fraction is important is that it is used to determine the grams of fiber per fuel assembly. The grams of fiber per fuel assembly is required to address the Limitations and Conditions in Section 4.0 of the Safety Evaluation Report (SER) for WCAP-16793-NP, Revision 2 [Ref. 3].
These conditions limit the amount of fiber reaching the fuel to 15 grams per fuel assembly for a hot leg break.
The grams of fiber per fuel assembly is calculated using Equation 1. This equation accounts for the only fiber debris source term at the strainer being latent debris
[Refs. 12 and 17].
__L=M*F*T*CF*B FA N
(Eq. 1)
Where:
g/F A grams of fiber per fuel assembly M
mass oflatent debris, 150 lbm [Refs. 12 and 17]
F fraction of latent debris that is fiber, 0.15 [Section 3.5.2.3 of Ref. 8]
N number of fuel assemblies, 193 assemblies [Ref. 7]
Calculation 2014-04466 Revision 1 Attachment A T
transport :fraction to strainer CF conversion from lbm to grams, 453.6 grams I lbm B
strainer fiber bypass fraction Equation I is simplified to Equation 2 by inserting known values.
__g__= 150*0.15*453.6 *T*B= 52.SS*T*B FA 193 Page A2 of Al 7 (Eq. 2)
It should be noted that the use of 150 lbm of latent debris is conservative relative to the amounts measured in containment as it exceeds the maximum measured amount by more than 20% [Refs. 12 and 17].
2.1 Clean Plant Criteria On December 22, 2011, a letter containing a simple set of resolution criteria (clean plant criteria) to address GSI-191 PWR sump performance for low fiber plants was issued by NEI [Ref. 1]. The NRC responded to these criteria in a letter dated May 2, 2012 [Ref. 2]. In the response, the NRC clarified the Staff's understanding of the criteria and concluded that "... the criteria, as clarified, provide an acceptable method of closing GSI-191 for operating PWRs."
The clean plant criteria, as applied to in-vessel effects, utilize a fiber bypass :fraction of 45% and a debris transport fraction of 75% [Ref. 1]. These values are acceptable to the NRC as demonstrated in the following excerpts :from Reference 2.
The highest bypass percentage observed by the staff for a fiber only test conducted for a low fiber plant with a typical complex geometry strainer under relatively conservative conditions is approximately 40%... the staff considers a bypass fraction of 45% to be conservative for most typical perforated plate strainer installations where flow patterns do not result in fragmentation of debris.
The staff concluded that an assumption of 7 5% transport to the strainer, as used in NEI's calculation, to be reasonable based on the following:
- 1. Inactive volumes: Plants may take credit for debris transport to inactive volumes. NRC staff guidance is that this value be limited to 15% regardless of the actual total inactive volume available for a specific plant. The 15%
limit is intended to account for delayed washdown of some debris which may not reach the holdup area before it is filled.
- 2. Fine debris capture: NUREGICR-6808 noted that there are several methods for fine debris capture. These are inertial impaction, diffusiophoresis, diffusion, settling, and spray washout. For latent debris it is unlikely that inertial impaction, diffusiophoresis, or diffusion would have a significant effect on debris capture. Settling and spray washout are likely to contribute
Calculation 2014-04466 Revision 1 Attachment A Page A3 of Al 7 to capture of latent debris. Capture by these mechanisms has been evaluated as likely for latent debris, but the effectiveness of the mechanisms has not been demonstrated and is plant specific. It is likely that some latent debris at all plants would be captured by these mechanisms.
- 3. Fine debris retention: NUREG/CR-6808 concluded that condensation drainage would leave a majority of fine debris in place, surfaces directly sprayed by containment sprays would have a majority of the fine debris removed, and that the retention of fine debris on surfaces experiencing spray drainage is uncertain.
The NRC then provided further justification for a 75% transport fraction [Ref. 2].
The staff concluded that the use of a lower [transport fraction] (e.g., 75%
transport fraction instead of at least 85% based on the SE to NEI-04-07) to calculate in-vessel limits for a clean plant is bolstered by the following unquantified conservatisms: I) some debris will not transport due to inactive holdup volumes and surface deposition, 2) in-vessel debris limits are determined using conservative test methodology, 3) in-vessel debris limits are determined at limiting values of flow and particulate to fiber ratio, 4) internal currents within the reactor vessel will likely result in nonuniform deposition of debris which is associated with reduced head loss, 5) most plants assume I 5%
of latent debris is fiber, based on an industry upper bound, but most low fiber plants have reported a significantly lower fraction of fiber in latent debris samples.
Based on the clean plant criteria values for debris transport fraction to the strainer (T) and strainer fiber bypass fraction (B), the following Byron I Braidwood specific in-vessel debris load is computed using Equation 2:
L = 52.88* T* B = 52.88* 0.75*0.45=17.8 g/FA FA This value exceeds the 15 grams per fuel assembly acceptance criterion. Therefore, the clean plant criteria cannot be used without modification. In order to use these criteria, a more appropriate fiber bypass fraction is determined based on the conditions expected for Byron/Braidwood.
2.2 Design Basis Fiber Bypass As discussed in Section 1.0, the NRC had concerns with the Byron/Braidwood plant specific fiber bypass testing. Therefore, the design basis is based on fiber bypass testing perfonned by CCI for other CCI strainers with the same size perforations
[2.1 mm or 1112 (0.083) inch per Refs. 21 and 22]. This approach is acceptable per Limitation 11 in Section 4.0 of the SER for WCAP-16793-NP, Revision 2 [Ref. 3],
which states the following:
Calculation 2014-04466 Revision 1 Attachment A Page A4 of Al 7 Licensees may determine the quantity of debris that passes through their strainers by... relying on strainer bypass values developed through strainer bypass testing of the same vendor and same perforation size, prorated to the licensee's plant specific strainer area; approach velocity; debris types, and debris quantities...
2.2.1 Industry Fiber Bypass Comparison A review of U.S. PWRs that installed CCI strainers was performed to determine an appropriate strainer bypass fraction for Byron/Braidwood. A summary of some of the pertinent information is provided below.
Salem [Refs. 4 and 5]: Strainers have the same perforation size. In 2006 (Bypass Test 9b) and 2008 (Bypass Test 3), CCI performed fiber bypass tests using only latent debris for Salem. These latent debris only tests are representative of some of the post-LOCA conditions expected at Byron and Braidwood (see summary in Table 2.1).
Palo Verde [Ref. 6]: Strainers have the same perforation size. Fiber bypass tests for Palo Verde, a low fiber plant, closely match limiting Byron I Braidwood conditions (see summary in Table 2.1 ).
D. C. Cook: Fiber bypass of 1.2% was measured and an assumed value of 5%
was used by Cook [Table 3n-1 in Attachment 4 to Ref. 10]. Additional details on bypass testing are not publicly available.
Oconee: Oconee credits the testing and results of Salem Nuclear Station for strainer bypass data [Item 13 in Enclosure to Ref. 9].
Calvert Cliffs: Strainers have a different perforation size [1/16 inch per Response to Issue 3jl in Attachment 1 to Ref. 11].
ANO 1 & 2: Strainers have a different perforation size [1/16 inch per Section A12 of Attachment 1 and Section B18 of Attachment 2 to Ref. 18].
R. E. Ginna: Strainer has a different perforation size [1116 inch per Section 3f.1.3 of Attachment 1 to Ref. 19].
Beaver Valley 1: Strainer has a different perforation size [1/16 inch per Section 3.j.1 of Attachment 1 to Ref. 20].
Based on the similarities in strainer design, debris load, and penetration velocity between Byron, Braidwood, Salem and Palo Verde, bypass testing data for Salem and Palo Verde are used to determine a conservative bypass fraction for Byron and Braidwood. Table 2.1 provides a comparison of strainer characteristics for Salem, Palo Verde, and Byron I Braidwood.
Calculation 2014-04466 Revision 1 Attachment A T bl 21 C a e. :
omparison o f S tram er Ch aracterist1cs Parameter Salem Palo Verde
[Refs. 4 and 5]
[Ref. 6]
Strainer 1112 inch 1/12 inch Perforation Size (0.083 inch)
Penetration Test 9b: 0.0041 ft/s 0.0094 ft/s Velocity (a)
Test 3: 0.0047 ft/s Effective Strainer Test 9b: 4,845 ft2 2,742 ft2 Area Test 3: 4,156 ff Flow Rate Test 9b: 9,000 gpm Max. flow rate through Single Test 3: 8,850 gpm of 11,600 gpm Strainer Train Latent fiber only Nukon fiber (c)
Debris Type and (both tests used 12.5 ft3 (Quantity not Quantity of Nukon fiber) available)
Theoretical Bed Test 9b: 0.031 in Not available Thickness (e)
Test 3: 0.036 in Page AS of Al 7 Byron I Braidwood 1112 inch
[2.1 mm; Refs. 21 & 22]
0.0047 ft/s before CS switchover; 0.0094 ft/s after CS switchover 2 160 ff (b)
Max. before CS (t) switchover: 4,557 gpm Max. after CS (g) switchover: 9,115 gpm Latent fiber only
[9.375 ft3 (d)]
0.052 in a) Penetration velocity = maximum flow rate through single strainer I effective strainer area [Vpen (ft/s) = Q (gpm)*(l min/60 sec)*(l ft3/7.48 gal) I Aettective ff].
b) Installed area (3059.5 ft2) less the sacrificial area (900 ft2) [Ref. 23].
c) Nukon is the only fiber type referred to in Reference 6.
d) Latent fiber as-fabricated volume (ft3) = latent debris mass [150 Ihm, Ref. 17]
- latent fiber fraction [0.15; Refs. 8 and 17] I latent fiber as-fabricated density
[2.4 lbm/ft3; p. 52 of Ref. 8]
e) Theoretical bed thickness (in) latent fiber as-fabricated volume (ft3) I effective strainer area (ff) * (12 in/ft) t) Maximum strainer flow prior to CS switchover is taken from Case 4 7B of Reference 14 which maximizes the residual heat removal (RH) pump flow during recirculation. The RH pump flow equals the strainer flow for this case.
Case 4 7B models one RH pump as operating; i.e. there is only flow through one strainer.
g) Maximum strainer flow is taken from Case 7B of Reference 14 [ 4640 gpm containment spray (CS) flow + 4475 gpm RH flow] which maximizes sump flow during recirculation. Case 7B models a one RH and one CS pump as operating; i.e. there is only flow through one strainer.
Calculation 2014-04466 Revision 1 Attachment A 2.2.2 Staggered RH and CS Pump Switchover Page A6 of Al 7 At Byron and Braidwood, the RH pump suction switchover (referred to as RH switchover herein) from the RWST to the Containment Recirculation Sump (referred to as "sump" herein) begins once the L0-2 level is reached in the RWST while CS pump suction switchover from the RWST to the Containment Recirculation Sump begins once the L0-3 level is reached in the RWST [Ref. 14].
The staggered switchover results in a period of time where the total flow through the Emergency Core Cooling System (ECCS) strainers is not the maximum strainer flow (which occurs following CS switchover). Since fiber bypass is impacted by penetration velocity, it is reasonable to model different fiber bypass fractions during recirculation for the times before and after CS switchover.
To analyze fiber bypass during staggered switchover, the fraction of fiber in the containment sump pool that reaches the strainers between RH and CS switchover is required. The fiber removed from the sump pool is estimated based on the fiber bypass fraction and the assumption that the debris is uniformly distributed in the pool. A uniform distribution of fiber is appropriate for Byron and Braidwood since the only fibrous debris is latent. By modeling the debris as being uniformly distributed throughout the pool, the amount of fiber in the pool at any time after recirculation can be related to pool turnovers. This method conservatively models all fiber that bypasses the strainer as immediately returning to the sump pool (i.e. no debris is retained downstream of the strainer). The equations and method used to determine the transient fiber concentration in the pool are provided below.
The mass of fiber in the pool (m) initially (i=O) is equal to the total mass of fiber (m101). This results in an initial fiber fraction (fo) of 1.
mo= mrot f;
m;lmror:fo I
(Eq. 3)
(Eq. 4)
The concentration of fiber in the pool (C) is based on the mass of fiber in the pool (m) and the pool volume (Vpoo1). Since the CS pumps continue to drawdown the RWST and supply the spray header in containment following RH switchover, the pool volume increases between RH and CS switchover. For this calculation, the average pool volume during this time is used.
(Eq. 5)
The volume of water flowing through the strainer (Vs1r) during a given time step is computed using the strainer flow rate (Q) and time step duration from i to i+ 1 (~t).
Vstr,itoi~J =Q *(fH1-tJ (Eq. 6)
Calculation 2014-04466 Revision 1 Attachment A Page A7 of Al 7 The number of pool turnovers flowing through the strainer during a time step (nro) is computed by dividing Equation 6 by the pool volume.
nro,;+1-nro,; = Vs1r,itoi+1 I Vpoot (Eq. 7a)
Vstr.i to;+ 1 = (nro,;+ 1 - nro,J
- Vpool (Eq. 7b)
The fiber quantity retained on the strainer (removed from the pool) (mr) in a given time step is computed using the fiber concentration, the water volume flowing through the strainer, and the fiber bypass fraction (fbypas5).
mr,; = C;
- Vstr,i to ;+1 * (1-fiypass)
(Eq. 8)
By substituting the definitions for fiber concentration (Eq. 4) and flow through the strainer (Eq. 7b) into Equation 8 and dividing by the total fiber mass, an equation for the fraction of fiber removed (fr) based on the fraction of total fiber in the pool (f), pool turnovers, and fiber bypass fraction is obtained.
mr,i I mtot = (m1 I VpooJ * [(nro,;+ J - nro,J
- VpooU * (1 - fiypass) I mtot fr.; = f; * (nro,;+ 1 - nro,J * (1 - fiypassJ (Eq. 9)
(Eq. 10)
The total mass of fiber in the pool for subsequent time steps (i ~ 1) is based on the fiber mass in the pool in the previous time step and the fiber removed during the previous time step.
m; = m;_J - mr,i-1 (Eq. 11)
Dividing by the total fiber mass results in an equation based on fiber fractions.
f; = /; fr.i-1 The cumulative amount of :fiber removed (%fiber,removed) is:
i
%fiber.removed = L fr,i i=O (Eq. 12)
(Eq. 13)
The transient fiber fraction in the pool as a function of pool turnovers is determined using Equations 4, 10, 12, and 13 in Attachment A.l and presented in Figure 2.1. A strainer bypass fraction of 15% (i.e. 85% of debris that transports to the strainer is captured) is used in the computation, consistent with the :findings in Section 2.2.5 for the time prior to CS switchover (see Figure 2.2). For the time prior to CS switchover, a bypass fraction of 15% is conservative as it greatly exceeds the expected fiber bypass based on bypass test data for other CCI strainers with a similar configuration to Byron/Braidwood.
Calculation 2014-04466 Revision 1 Attachment A 2.2.3 Pool Turnovers between RH and CS Switchover Page A8 of Al 7 To determine the maximum amount of fiber subject to the higher strainer velocities after CS switchover, the minimum amount of fiber retained on the strainer between RH and CS switchover is determined using Figure 2.1 and the number of pool turnovers between RH and CS switchover. The number of turnovers is determined as follows.
(Eq. 14)
Where:
nro number of pool turnovers between RH and CS switchover Q
recirculation flow rate between RH and CS switchover (for either 1 or 2 train operation)
Lit time between RH and CS switchover Vpool average pool volume between RH and CS switchover The number of turnovers between RH and CS switchover is determined based on the cases presented in the minimum and maximum flood level calculations
[Refs. 24 & 25, respectively] since these design basis documents contain all required information (modeled flow rates, switchover times, and pool volumes) and assess the limiting pool volumes. The minimum flood level calculation includes both 1 and 2 train operation cases, while the maximum flood level calculation includes only 2 train operation cases. Thus, the number of turnovers computed encompasses both 1 and 2 train operation.
Attachment A.2 computes the number of turnovers between RH and CS switchover for each case analyzed in the flood level calculations. Note, Reference 24 refers to ECCS switchover, which includes all ECCS pumps (CV, SI, RH), not just the RH pumps. The timing ofECCS switchover is the same as RH switchover since the RH pumps are part of the Emergency Core Cooling System. The discussion herein refers to RH switchover since the RH pumps are the only ECCS pumps to take suction from the sump following switchover.
The computed number of turnovers for the maximum flood scenarios is based on ATD-0111 [Ref. 25]. However, the maximum flood level analysis models one RH suction valve from the RWST as failing to close at RH switchover which results in an RH pump assisting in the drawdown of the RWST (following RH switchover) and direct gravity feed from the RWST to the sump, both of which reduce the time between RH and CS switchover. Furthermore, the maximum flood level analysis predicts the sump water level assuming that the entire RWST empties, which increases the time between RH and CS switchover. To determine a reasonable number of turnovers, the results from Reference 25 are adjusted in Attachment A.2
Calculation 2014-04466 Revision 1 Attachment A Page A9 of Al 7 as described below to reflect more realistic conditions and to determine the sump volume at CS switchover initiation. Three main adjustments are made.
- 1) RWST Outflow: The turnovers for the maximum flood scenarios are computed in Attachment A.2 assuming the RWST to RH pump isolation valves both close properly, which results in less RWST outflow following the completion of RH switchover than modeled in Reference 25. This adjustment also results in two RH pumps drawing from the sump following RH switchover. The revised RWST outflow consists of two trains CS, CV, and SI flow and is modeled as continuing until the point of CS switchover initiation [Design Input 4.3 of Ref. 25]. Since the time between RH switchover completion and CS switchover initiation is less than 412 seconds, SI switchover is not complete prior to CS switchover initiation. Thus, the RWST outflow is modeled as constant between RH switchover completion and CS switchover initiation.
- 2) Sump Volume at CS Switchover: To determine the sump volume at CS switchover, first the RWST volume at CS switchover is determined using the RWST level at CS switchover initiation (L0-3, 12%) and corresponding RWST volume at this point from Reference 26. Once the RWST volume at CS switchover initiation and RH switchover completion (from Ref. 25) are known, the total RWST volume injected between RH switchover completion and CS switchover initiation is computed along with the time to inject this volume using the flow rate from Adjustment 1 above. The sump volume at CS switchover initiation is then computed by subtracting the volume of water remaining in the RWST at CS switchover initiation from the computed sump volume in Reference 25 at a time approximately equal to the time of CS switchover initiation (~1560 seconds). The sump volume at this time in Reference 25 is based on the entire RWST having been injected into the sump (i.e. empty RWST).
- 3) Sump Flow Rate: The flow rate out of the sump is based on two train operation (i.e. two RH pumps) to be consistent with Adjustment 1 above. For two train operation prior to CS switchover initiation, one RH pump draws from each ECCS sump strainer.
The number of turnovers between RH and CS switchover ranges from 0.26 (for maximum flood scenarios) to 1.0 (for minimum flood scenarios), as shown in Attachment A.2. Given the conservatisms already being used in this assessment (e.g. design latent debris mass and latent fiber fraction) as well as the conservatisms employed in the flood level calculations, the median value of 0.63 turnovers between RH and CS switchover is used. This is consistent with the NRC guidance to treat GSI-191 holistically [Ref. 13]. It should also be noted that the use of 15 grams of fiber per fuel assembly as an in-vessel fiber acceptance criterion is conservative, as acknowledged by the NRC in the SER for WCAP-16793 [p. 36 of Ref. 3], which states:
Calculation 2014-04466 Revision 1 Attachment A PageA10ofA17 The NRC staff finds that a 15 gram fiber limit is a conservative value for all plant types included in the WCAP...
Finally, the bypass fractions chosen for design in Section 2.2.5 below are also conservative and include significant margin over the expected values.
2.2.4 Fiber Retained on Strainer Prior to CS Switchover Figure 2.1 shows that after 0.63 turnovers a minimum of 42% of the fibrous debris has been removed from the active pool. Note, the fraction of fiber on the screen prior to CS switchover would be slightly higher ifthe debris transported during pool fill-up were accounted for since some debris reaches the strainer prior to recirculation. Both recirculation sump pits would be filled during pool fill-up regardless of whether one or two ECCS/CS trains are in operation.
100%
90%
~
~
80%
s..
~ 70%
=
e'iS s..
60%
ff.)
=
0 50%
s..
40%
~
.c...
~ 30%
e'iS 20%
~
10%
0%
0 0.5 1.5 2
2.5 3
Sump Pool Turnovers Figure 2.1: Fiber Capture on Strainer To be conservative, only 40% fiber capture prior to CS switchover is assumed for this analysis. This is conservative as slightly more fiber is subjected to a higher bypass. The plant flow rate, screen penetration velocity and fraction of debris reaching the strainer are provided in Table 2.2 for the time before and after CS recirculation switchover.
Calculation 2014-04466 Revision 1 T bl 2 2 B a e. : iyron Before CS Switchover After CS Switchover Attachment A
/B "d
ra1 woo dP arameters Byron/Braidwood Plant Flow Rate<a>
4,557 gpm 9,115 gpm a) See Table 2.1 for basis.
2.2.5 Overall Fiber Bypass Fraction Page All of Al 7 Penetration Fraction of Debris Velocity(a)
Reachin2 Strainer 0.0047 ft/s 40%
0.0094 ft/s 60%
Once the fraction of debris reaching the strainer prior to CS recirculation switchover is determined, an overall fiber bypass fraction (B) can be calculated.
B = XEees
- BEees + Xes *Bes = 0.40
- BEees + 0.60 *Bes (Eq. 15)
Where:
XEccs fraction of debris reaching strainer before CS switchover Xcs fraction of debris reaching strainer after CS switchover BEccs fiber bypass fraction for debris reaching strainer before CS switchover Bes fiber bypass fraction for debris reaching strainer after CS switchover To determine the appropriate fiber bypass fractions for before and after CS switchover, data from Salem and Palo Verde is utilized.
Table 2.3 and Figure 2.2 present the Salem and Palo Verde fiber bypass test data as bypass percentage versus penetration velocity. The Salem fiber bypass data is computed based on the information presented in References 4 and 5, as explained below. The Palo Verde fiber bypass data (without bump-up) is taken from p. 3-155 of Reference 6.
The fiber bypass for Salem Test 9b in 2006 is 0.25 Ihm per 1000 ft2 [Figure 3f.4.2.2.2-2 of Attachment 1 to Ref. 4]. Given the tested plant strainer area of 4845 ft2 [Section 3f.4.1.3.2 of Attachment 1 to Ref. 4], this corresponds to 1.21 lbm
[=0.25*4845/1000] of fiber bypass. To compute the total fiber added to the test loop for this test, the scale factor (180.8) and added fiber mass (0.0623 kg) are used
[Section 3f.4.1.3.4 of Attachment 1 to Ref. 4]. The total fiber added to the test loop for this test was equivalent to 24.83 Ihm in the plant [=180.8*0.0623*2.2046].
- Thus, the measured fiber bypass percentage for this test is 4.87%
[=1.21124.83* 100].
The reason 12.5 ft3 of latent fiber is not equal to 30 Ihm for Salem Test 9b in 2006 is that the measured Nukon density (1.94 lbm/ft3) was used for the conversion from as-fabricated volume to mass in this test series as explained on p. 10 of to Reference 5. The measured density is less than the typically used
Calculation 2014-04466 Revision 1 Attachment A Page A12 of Al 7 density of 2.4 lbm/ft3 [p. 52 of Ref. 8]. It is also recognized that 12.5 ft3 of 1.94 lbm/ft3 fiber yields 24.25 Ihm; the difference between this value and the computed value above (24.83 lbm) is presumably due to truncation errors in the computation (original density was probably in kg/m3 and then converted to lbm/ft3).
The fiber bypass for Salem Test 3 in 2008 is 0.68 Ihm per 1000 ft2 [p. 10 of to Ref. 5]. Given the tested plant strainer area of 4156 ft2 [Sections 3f.4.l.5.4 and 3f.4.1.6.2 of Attachment 1 to Ref. 4], this corresponds to 2.83 lbm
[=0.68*4156/1000] of fiber bypass. The total fiber added to the test loop for this test was equivalent to 30 lbm in the plant [p. 141 of Attachment 1 to Ref. 4]. Thus, the measured fiber bypass percentage for this test is 9.43% [=2.83/30*100].
The amount of bypassed fibers for Salem and Palo Verde is increased by 9% to account for NRC concerns with the fiber bypass capture screen used in the CCI fiber bypass tests [Attachment 1 of Ref. 5]. Specifically, the NRC was concerned that some fiber that bypassed the strainer would then pass through the fiber capture screen due to the capture screen hole size of 0.31 mm [0.012 inch in Ref 6]. To account for potential capture screen bypass during the tests, an increase factor was developed by Salem and accepted by the NRC [Refs. 27 and 28].
T bl 2 3 S I a e.. a em an dP I V d F'b B
ao er e 1 er iypass T tD t es aa Test Data Penetration Fiber Bypass Fiber Bypass Velocity with Bump-Up (ft/s)
(%)
(%)
Salem (2006 Test 9b) 0.0041 4.87 5.3 Salem (2008 Test 3) 0.0047 9.43 10.3 Palo Verde (Test 02) 0.0094 8.1 8.8 Palo Verde (Test 03) 0.0094 12.3 13.4 Two points are added to Figure 2.2 to represent the bypass fractions used for Byron and Braidwood before and after CS recirculation switchover. Note that these points are based on the maximum penetration velocities during recirculation before and after CS switchover. This is conservative, as most operating scenarios will experience lower penetration velocities. As noted in Notes '-f and 'g' to Table 2.1, these penetration velocities are based on single train operation, even though two train operation would be expected [Ref. 15] and two train operation would have lower strainer flow rates/penetration velocities. Two train operation would result in higher flow rates and pressure drop through shared portions of the system (e.g. RCS legs), resulting in less flow rate per pump (and hence per sump strainer) than for single train operation. This is consistent with Section 6.1.5.1 of Reference 14 which describes the system line-up (i.e. single train) for maximum sump flow.
Before CS recirculation switchover a fiber bypass fraction of 15% is used. This conservatively bounds the bypass data at similar penetration velocities with approximately 50% margin.
Calculation 2014-04466 Revision 1 Attachment A Page Al3 of Al 7 The maximum penetration velocity after CS recirculation switchover is equal to that used in the Palo Verde fiber bypass tests. To be conservative, a bypass fraction of 40% is used for fiber that reaches the strainer after CS recirculation switchover.
This value is consistent with the highest bypass percentage observed by the Staff for a fiber only test for a low fiber plant with a complex geometry strainer [Ref. 2]. As can be seen in Figure 2.2, this value is very conservative relative to the Salem and Palo Verde data.
50%
I 45%
I NRC Clean Plant Bypass Fraction I
40%
~
35%
!.... 30%
I i
- Salem Fiber Bypass Data
- Palo Verde Fiber Bypass Data T
IA Values Used for BYR/BRW
('I 25%
- g.
.... =
i..
20%
41
Penetration Velocity Before CS Switchover
- Penetration Velocity After CS Switchover I
.c I
~ 15%
10%
5%
.l t
I -
T T
I I
I I
0%
I 0
0.002 0.004 0.006 0.008 0.01 Penetration Velocity [ft/s]
Figure 2.2: Fiber Bypass versus Penetration Velocity Based on the data in Figure 2.2, the following overall bypass fraction is calculated for Byron and Braidwood using Equation 15.
B = XEccs
- BEccs +Xcs *Bes= 0.40
- 0.15 + 0.60
- 0.40 = 0.300 = 30.0%
2.3 In-Vessel Fiber Loading The quantity of fiber per fuel assembly is calculated below using Equation 2 with a bypass fraction (B) of 30%. The transport fraction to the strainer (T) is maintained at the clean plant criteria value (75%).
__L = 52.88
- T
- B = 52.88
- 0.75*0.30=11.9 g/ FA FA This value is less than the 15 grams per fuel assembly acceptance criterion.
Calculation 2014-04466 Revision 1 3.0 Conclusions Attachment A Page A14 of Al 7 This attachment determines that an appropriate fiber bypass fraction to use for the CCI strainers at Byron and Braidwood is 30%. This value is based on both testing of other CCI strainers as well as a recognized conservative fiber bypass fraction through complex, perforated plate strainers.
Using the fiber bypass value above, the in-vessel fiber loading is 11.9 grams per fuel assembly.
The in-vessel fiber loading is computed using the clean plant criteria, but with the more appropriate fiber bypass fraction determined herein. This is the only difference between the approach for Byron/Braidwood and the clean plant criteria.
The reduced fiber bypass fraction is justified due to the lower penetration velocity before CS recirculation switchover and by adding significant margin to available industry fiber bypass data.
4.0 References
- 1.
Letter from J. Butler (NEI) to S. Bailey (NRC) dated December 22, 2011, "Transmittal of GSI-191 Resolution Criteria for "Low Fiber" Plants." ADAMS Accession No. MLl 13570229.
- 2.
Letter from W. Ruland (NRC) to J. Butler (NEI) dated May 2, 2012, "NRC Review of Nuclear Energy Institute Clean Plant Acceptance Criteria for Emergency Core Cooling Systems." ADAMS Accession No. ML120730181.
- 3.
Safety Evaluation by the Office of Nuclear Reactor Regulation to WCAP-16793-NP, Revision 2, "Evaluation of Long-Term Cooling Considering Particulate, Fibrous and Chemical Debris in the Recirculating Fluid," October 2011 (ADAMS Accession No. ML12084Al54). Transmitted via letter from Sher Bahadur (NRC) to Anthony Nowinowski (PWR Owners Group), on April 8, 2013, (ADAMS Accession No. ML13084A152)).
- 4.
PSEG Letter No. LR-N12-0124 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Supplemental Response to Generic Letter 2004-02, Including Attachment 1, "Salem Nuclear Generating Station Units 1 and 2 Docket Nos. 50-272 and 50-311 Generic Letter 2004-02 Updated Supplemental Response for Salem," dated April 27, 2012. ADAMS Accession Nos. ML12129A389 & ML12129A390.
- 5.
PSEG Letter No. LR-N13-0091 from Carl J. Fricker (Salem) to USNRC,
Subject:
Final Responses to NRC Questions Regarding Salem Bypass Testing, dated April 22, 2013. ADAMS Accession No. ML13114A048.
- 6.
APS Letter No. 102-06805-DCMIRKR from John J. Cadogan (Palo Verde) to USNRC,
Subject:
Palo Verde Nuclear Generating Station (PVNGS) Units 1, 2, and 3 Docket Nos. STN 50-528, 50-529, and 50-530 Revision 2 to Supplemental
Calculation 2014-04466 Revision 1 Attachment A Page A15 of Al 7 Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors, dated December 18, 2013. ADAMS Accession No. ML13357A218.
- 7.
Byron/Braidwood UFSAR, Revision 15, Table 4.1-1.
- 8.
Safety Evaluation by the Office of Nuclear Reactor Regulation Related to NRC Generic Letter 2004-02, Nuclear Energy Institute Guidance Report (Proposed Document Number NEI 04-07), "Pressurized Water Reactor Sump Performance Evaluation Methodology." ADAMS Accession No. ML043280641.
- 9.
Duke Energy Letter No. ONS-2014-024 from Scott L. Batson (Oconee) to USNRC,
Subject:
Oconee Closure Option 1 Response for Generic Safety Issue (GSI)-191, "Assessment of Debris Accumulation on Pressurized-Water Reactor Sump Performance" in Resolution of Final Issues Related to Generic Letter (GL) 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated February 27, 2014. ADAMS Accession No. ML14065A040.
- 10.
AEP Letter No. AEP-NRC-2010-39 from Joel P. Gebbie (AEP) to USNRC,
Subject:
Updated Final Response to Nuclear Regulatory Commission Generic Letter 2004-02: Potential impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors and a June 2009 Request for Additional Information, dated May 26, 2010. ADAMS Accession No. ML101540527.
- 11.
Constellation Energy Nuclear Generation Group (James A. Spina I Calvert Cliffs)
Letter to the USNRC,
Subject:
Calvert Cliffs Nuclear Power Plant Unit Nos. 1 & 2; Docket Nos. 50-317 & 50-318, Supplemental Response to Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized Water Reactors," dated February 29, 2008. ADAMS Accession No. ML080640751.
- 12.
Exelon Letter No. RS-07-161 from Patrick R. Simpson (Exelon) to USNRC, "Supplemental Response to NRC Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated December 31, 2007. ADAMS Accession No. ML080280562.
- 13.
NRC Staff Memorandum from A. L. Bates to L. A. Reyes,
Subject:
Staff Requirements -
Briefing on Resolution of GSI-191, Assessment of Debris Accumulation on PWR Sump Performance, 1 :30 P.M., Wednesday, October 25, 2006, Commissioners' Conference Room, One White Flint North, Rockville, Maryland (Open to Public Attendance), dated November 16, 2006, M061025C.
ADAMS Accession No. ML063200471.
Calculation 2014-04466 Revision 1 Attachment A Page A16 of Al 7
- 14.
Calculation BYR06-029 I BRW-06-0016-M, Rev. S, "SI/RHR/CS/CV System Hydraulic Analysis in Support of GSI-191." Byron currently uses Rev. S, and Braidwood uses Revs.Sand SA. The information used herein is from Rev.Sand is not impacted by Rev. SA.
1 S.
Byron I Braidwood Procedures lS.1 lBEP ES-1.3, Rev. 206, "Transfer to Cold Leg Recirculation Unit 1."
lS.2 2BEP ES-1.3, Rev. 206, "Transfer to Cold Leg Recirculation Unit 2."
lS.3 lBwEP ES-1.3, Rev. 203, "Transfer to Cold Leg Recirculation Unit l."
lS.4 2BwEP ES-1.3, Rev. 203, "Transfer to Cold Leg Recirculation Unit 2."
- 16.
Exelon Letter RS-lS-283 from David M. Gullott (Exelon) to USNRC,
Subject:
Closeout Documentation for Resolution of Generic Letter 2004-02 (Generic Safety Issue (GSI)-191), dated October 30, 201S, Including Attachment "Braidwood Station and Byron Station, Design Analysis 2014-04466, Revision 0, Assessment of the NRC Safety Evaluation Limitations and Conditions Associated with WCAP-1 6793-NP." ADAMS Accession No. ML1S303A408.
- 17.
Calculation No. BRW-OS-OOS9-M I BYROS-041, Rev. 2, "GSI-191 Post-LOCA Debris Generation."
- 18.
Entergy Letter No. OCAN090901 from Kevin T. Walsh (ANO) to USNRC,
Subject:
Generic Letter 2004-02 Final Supplemental Response Request for Additional Information Arkansas Nuclear One - Units 1 and 2 Docket Nos. S0-313 and S0-368 License Nos. DPR-Sl and NPF-6, dated September 24, 2009. ADAMS Accession No. ML092720684.
- 19.
Constellation Energy Nuclear Generation Group (John Carlin IR. E. Ginna) Letter to the USNRC,
Subject:
Supplementary Response to Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors," dated February 29, 2008. ADAMS Accession No. ML080710041.
- 20.
FirstEnergy Nuclear Operating Company (FENOC) Letter No. L-09-1S2 from Peter P. Sena III (Beaver Valley) to USNRC,
Subject:
Supplemental Response to Generic Letter 2004-02 (TAC Nos. MC466S and MC4666), dated June 30, 2009. ADAMS Accession No. ML091830390.
- 21.
CCI Drawing 103.132.173.SOO, Revision 0, "Side Wall Long Version Seitenwand Lange Version Type 4."
- 22.
CCI Drawing 103.132.174.SOO, Revision 0, "Pocket Long Version Tasche Lange Version."
- 23.
CCI Report 3 SA-096.018, Revisions 8 (Byron) and 9 (Braidwood), "Head Loss Calculation." The information used herein is the same in Revisions 8 and 9.
Calculation 2014-04466 Revision 1 Attachment A Page A 1 7 of A 1 7
- 24.
Calculation SI-90-01, Revision 11, "Minimum Containment Flood Level."
- 25.
Calculation ATD-0111, Revision 15, "Maximum Containment Flood Level."
- 26.
Calculation SITH-1, Revision 8, "Refueling Water Storage Tank (RWST) Level Setpoints."
- 27.
NRC Letter (John G. Lamb) to PSEG (Thomas Joyce),
Subject:
Salem Nuclear Generating Station, Units 1 and 2 - Close-out of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors" (TAC Nos. MC4712 and MC4713),
dated April 30, 2014. ADAMS Accession No. ML14113A202.
- 28.
U.S. Nuclear Regulatory Commission Staff Review of the Documentation Provided by PSEG Nuclear, LLC, for Salem Nuclear Generating Station, Units 1 and 2, Concerning Resolution of Generic Letter 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors." ADAMS Accession No. ML14113A221.
The following Byron/Braidwood drawing and calculation References were verified as current in PASSPORT on 3/14/2016: 7, 14, 15, 17, 24, 25, and 26.
5.0 Attachments (to Attachment A of2014-04466)
Attachment A.1: Transient Fiber Fraction in Sump Pool (12 pages)
Attachment A.2: Pool Turnovers Between ECCS and CS Switchover (12 pages)
Calculation 2014-04466 Revision 1 A
8 1 Strainer Bypass Fraction, fbypass 2
Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 = 1.0 3
nro f; =f1..1 *f*L* (i?:.1) 4 0.00 1.00 5
0.01 0.99 6
0.02 0.98 7
0.03 0.97 8
0.04 0.97 9
0.05 0.96 10 0.06 0.95 11 0.07 0.94 12 0.08 0.93 13 0.09 0.93 14 0.10 0.92 15 0.11 0.91 16 0.12 0.90 17 0.13 0.89 18 0.14 0.89 19 0.15 0.88 20 0.16 0.87 21 0.17 0.86 22 0.18 0.86 23 0.19 0.85 24 0.20 0.84 25 0.21 0.84 26 0.22 0.83 27 0.23 0.82 28 0.24 0.81 29 0.25 0.81 30 0.26 0.80 31 0.27 0.79 32 0.28 0.79 33 0.29 0.78 34 0.30 0.77 35 0.31 0.77 36 0.32 0.76 37 0.33 0.75 38 0.34 0.75 39 0.35 0.74 40 0.36 0.74 Attachment A.1 Page A. 1-1 of A. 1-12 c
D 0.15 Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,1 = f1 * (n ro,1+1
- n ro,1) * (1*f bypass)
% f/ber,removed = If r,I from i=O to i 0.0085 0.9%
0.0084 1.7%
0.0084 2.5%
0.0083 3.4%
0.0082 4.2%
0.0081 5.0%
0.0081 5.8%
0.0080 6.6%
0.0079 7.4%
0.0079 8.2%
0.0078 9.0%
0.0077 9.7%
0.0077 10.5%
0.0076 11.3%
0.0075 12.0%
0.0075 12.8%
0.0074 13.5%
0.0074 14.2%
0.0073 15.0%
0.0072 15.7%
0.0072 16.4%
0.0071 17.1%
0.0070 17.8%
0.0070 18.5%
0.0069 19.2%
0.0069 19.9%
0.0068 20.6%
0.0068 21.3%
0.0067 21.9%
0.0066 22.6%
0.0066 23.3%
0.0065 23.9%
0.0065 24.5%
0.0064 25.2%
0.0064 25.8%
0.0063 26.5%
0.0063 27.1%
Att A.1
Calculation 2014-04466 Revision 1 A
8 Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f1 =f1..1 *f.u {i~1) 41 0.37 0.73 42 0.38 0.72 43 0.39 0.72 44 0.40 0.71 45 0.41 0.70 46 0.42 0.70 47 0.43 0.69 48 0.44 0.69 49 0.45 0.68 50 0.46 0.68 51 0.47 0.67 52 0.48 0.66 53 0.49 0.66 54 0.50 0.65 55 0.51 0.65 56 0.52 0.64 57 0.53 0.64 58 0.54 0.63 59 0.55 0.63 60 0.56 0.62 61 0.57 0.61 62 0.58 0.61 63 0.59 0.60 64 0.60 0.60 65 0.61 0.59 66 0.62 0.59 67 0.63 0.58 68 0.64 0.58 69 0.65 0.57 70 0.66 0.57 71 0.67 0.56 72 0.68 0.56 73 0.69 0.55 74 0.70 0.55 75 0.71 0.55 76 0.72 0.54 77 0.73 0.54 78 0.74 0.53 Attachment A.1 Page A. 1-2 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed From Pool (Eq.13)
Removed from Pool (Eq. 10)
% fiber,removed = If r,i f r,i : f; * (n TO,i+1
- n TO,;) * (1-f bypass) from i=O to i 0.0062 27.7%
0.0061 28.3%
0.0061 28.9%
0.0060 29.5%
0.0060 30.1%
0.0059 30.7%
0.0059 31.3%
0.0058 31.9%
0.0058 32.5%
0.0057 33.0%
0.0057 33.6%
0.0056 34.2%
0.0056 34.7%
0.0055 35.3%
0.0055 35.8%
0.0055 36.4%
0.0054 36.9%
0.0054 37.5%
0.0053 38.0%
0.0053 38.5%
0.0052 39.0%
0.0052 39.6%
0.0051 40.1%
0.0051 40.6%
0.0050 41.1%
0.0050 41.6%
0.0050 42.1%
0.0049 42.6%
0.0049 43.1%
0.0048 43.6%
0.0048 44.0%
0.0048 44.5%
0.0047 45.0%
0.0047 45.5%
0.0046 45.9%
0.0046 46.4%
0.0046 46.8%
0.0045 47.3%
Att A.1
Calculation 2014-04466 Revision 1 A
8 Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f1 = f 1.1 - f.** (i ~ 1) 79 0.75 0.53 80 0.76 0.52 81 0.77 0.52 82 0.78 0.51 83 0.79 0.51 84 0.80 0.51 85 0.81 0.50 86 0.82 0.50 87 0.83 0.49 88 0.84 0.49 89 0.85 0.48 90 0.86 0.48 91 0.87 0.48 92 0.88 0.47 93 0.89 0.47 94 0.90 0.46 95 0.91 0.46 96 0.92 0.46 97 0.93 0.45 98 0.94 0.45 99 0.95 0.44 100 0.96 0.44 101 0.97 0.44 102 0.98 0.43 103 0.99 0.43 104 1.00 0.43 105 1.01 0.42 106 1.02 0.42 107 1.03 0.42 108 1.04 0.41 109 1.05 0.41 110 1.06 0.40 111 1.07 0.40 112 1.08 0.40 113 1.09 0.39 114 1.10 0.39 115 1.11 0.39 116 1.12 0.38 Attachment A.1 Page A.1-3 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,i : f1 * (n T0,1+1 "n TO,/) * (1-f bypass)
% fiber,removad = I:f r,/
from i=O to i 0.0045 47.7%
0.0044 48.2%
0.0044 48.6%
0.0044 49.1%
0.0043 49.5%
0.0043 49.9%
0.0043 50.3%
0.0042 50.8%
0.0042 51.2%
0.0041 51.6%
0.0041 52.0%
0.0041 52.4%
0.0040 52.8%
0.0040 53.2%
0.0040 53.6%
0.0039 54.0%
0.0039 54.4%
0.0039 54.8%
0.0038 55.2%
0.0038 55.6%
0.0038 55.9%
0.0037 56.3%
0.0037 56.7%
0.0037 57.0%
0.0037 57.4%
0.0036 57.8%
0.0036 58.1%
0.0036 58.5%
0.0035 58.8%
0.0035 59.2%
0.0035 59.5%
0.0034 59.9%
0.0034 60.2%
0.0034 60.6%
0.0034 60.9%
0.0033 61.2%
0.0033 61.6%
0.0033 61.9%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f, = fu
- frL* (i~ 1) 117 1.13 0.38 118 1.14 0.38 119 1.15 0.37 120 1.16 0.37 121 1.17 0.37 122 1.18 0.37 123 1.19 0.36 124 1.20 0.36 125 1.21 0.36 126 1.22 0.35 127 1.23 0.35 128 1.24 0.35 129 1.25 0.34 130 1.26 0.34 131 1.27 0.34 132 1.28 0.34 133 1.29 0.33 134 1.30 0.33 135 1.31 0.33 136 1.32 0.32 137 1.33 0.32 138 1.34 0.32 139 1.35 0.32 140 1.36 0.31 141 1.37 0.31 142 1.38 0.31 143 1.39 0.31 144 1.40 0.30 145 1.41 0.30 146 1.42 0.30 147 1.43 0.30 148 1.44 0.29 149 1.45 0.29 150 1.46 0.29 151 1.47 0.29 152 1.48 0.28 153 1.49 0.28 154 1.50 0.28 Attachment A.1 Page A.1-4 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed From Pool (Eq. 13)
Removed from Pool (Eq. 10)
% fiber.removed= If r,i f r,i : f; * (n TO,i+1
- n TO,;) * (1*f bypess) from i=O to i 0.0032 62.2%
0.0032 62.5%
0.0032 62.9%
0.0032 63.2%
0.0031 63.5%
0.0031 63.8%
0.0031 64.1%
0.0031 64.4%
0.0030 64.7%
0.0030 65.0%
0.0030 65.3%
0.0029 65.6%
0.0029 65.9%
0.0029 66.2%
0.0029 66.5%
0.0029 66.8%
0.0028 67.0%
0.0028 67.3%
0.0028 67.6%
0.0028 67.9%
0.0027 68.1%
0.0027 68.4%
0.0027 68.7%
0.0027 68.9%
0.0026 69.2%
0.0026 69.5%
0.0026 69.7%
0.0026 70.0%
0.0026 70.2%
0.0025 70.5%
0.0025 70.7%
0.0025 71.0%
0.0025 71.2%
0.0024 71.5%
0.0024 71.7%
0.0024 72.0%
0.0024 72.2%
0.0047 72.7%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro
- f. =f1.1.f_. (i~1) 155 1.52 0.27 156 1.54 0.27 157 1.56 0.26 158 1.58 0.26 159 1.60 0.26 160 1.62 0.25 161 1.64 0.25 162 1.66 0.24 163 1.68 0.24 164 1.70 0.23 165 1.72 0.23 166 1.74 0.23 167 1.76 0.22 168 1.78 0.22 169 1.80 0.21 170 1.82 0.21 171 1.84 0.21 172 1.86 0.20 173 1.88 0.20 174 1.90 0.20 175 1.92 0.19 176 1.94 0.19 177 1.96 0.19 178 1.98 0.18 179 2.00 0.18 180 2.02 0.18 181 2.04 0.17 182 2.06 0.17 183 2.08 0.17 184 2.10 0.17 185 2.12 0.16 186 2.14 0.16 187 2.16 0.16 188 2.18 0.16 189 2.20 0.15 190 2.22 0.15 191 2.24 0.15 192 2.26 0.14 Attachment A.1 Page A.1-5 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq.13) f r,I = f1 * (n T0,1+1 "n TO,I) * (1*f bypass)
% fiber.removed=,Ef r,I from i=O to i 0.0046 73.1%
0.0046 73.6%
0.0045 74.1%
0.0044 74.5%
0.0043 74.9%
0.0043 75.4%
0.0042 75.8%
0.0041 76.2%
0.0040 76.6%
0.0040 77.0%
0.0039 77.4%
0.0038 77.8%
0.0038 78.1%
0.0037 78.5%
0.0037 78.9%
0.0036 79.2%
0.0035 79.6%
0.0035 79.9%
0.0034 80.3%
0.0034 80.6%
0.0033 80.9%
0.0032 81.3%
0.0032 81.6%
0.0031 81.9%
0.0031 82.2%
0.0030 82.5%
0.0030 82.8%
0.0029 83.1%
0.0029 83.4%
0.0028 83.7%
0.0028 83.9%
0.0027 84.2%
0.0027 84.5%
0.0026 84.7%
0.0026 85.0%
0.0025 85.3%
0.0025 85.5%
0.0025 85.8%
Att A.1
Calculation 2014-04466 Revision 1 A
B Number of Fraction of Fiber Mass Pool in Pool (Eq. 4 & 12)
Turnovers f 0 =1.0 3
nro f/ = fi..1 "f.L4 (i?.1) 193 2.28 0.14 194 2.30 0.14 195 2.32 0.14 196 2.34 0.14 197 2.36 0.13 198 2.38 0.13 199 2.40 0.13 200 2.42 0.13 201 2.44 0.12 202 2.46 0.12 203 2.48 0.12 204 2.50 0.12 205 2.52 0.12 206 2.54 0.11 207 2.56 0.11 208 2.58 0.11 209 2.60 0.11 210 2.62 0.11 211 2.64 0.10 212 2.66 0.10 213 2.68 0.10 214 2.70 0.10 215 2.72 0.10 216 2.74 0.10 217 2.76 0.09 218 2.78 0.09 219 2.80 0.09 220 2.82 0.09 221 2.84 0.09 222 2.86 0.09 223 2.88 0.09 224 2.90 0.08 225 2.92 0.08 226 2.94 0.08 227 2.96 0.08 228 2.98 0.08 229 3.00 0.08 230 3.02 Attachment A.1 Page A. 1-6 of A. 1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq.13) f r,I : f1 * (n T0,1+1 "n TO,I) * (1*f bypass)
% f/ber,removed = l:f r,i from i=O to i 0.0024 86.0%
0.0024 86.2%
0.0023 86.5%
0.0023 86.7%
0.0023 86.9%
0.0022 87.2%
0.0022 87.4%
0.0021 87.6%
0.0021 87.8%
0.0021 88.0%
0.0020 88.2%
0.0020 88.4%
0.0020 88.6%
0.0019 88.8%
0.0019 89.0%
0.0019 89.2%
0.0018 89.4%
0.0018 89.5%
0.0018 89.7%
0.0017 89.9%
0.0017 90.1%
0.0017 90.2%
0.0017 90.4%
0.0016 90.6%
0.0016 90.7%
0.0016 90.9%
0.0016 91.0%
0.0015 91.2%
0.0015 91.3%
0.0015 91.5%
0.0014 91.6%
0.0014 91.8%
0.0014 91.9%
0.0014 92.1%
0.0014 92.2%
0.0013 92.3%
0.0013 92.4%
AttA.1
Calculation 2014-04466 Revision 1 A
B 1 Strainer Bypass Fraction, fbypass 2
Number of Pool Fraction of Fiber Mass in Turnovers Pool (Eq. 4 & 12) nro f 0 = 1.0 3
f1 =
f1 fr,1-1 (i ~ 1) 4 0 1
5 =A4+0.01
=B4-C4 6 =A5+0.01
=B5-C5 7 =A6+0.01
=B6-C6 8 =A7+0.01
=B7-C7 9 =A8+0.01
=88-C8 10 =A9+0.01
=B9-C9 11 =A10+0.01
=810-C10 12 =A11+0.01
=B11-C11 13 =A12+0.01
=B12-C12 14 =A13+0.01
=813-C13 15 =A14+0.01
=B14-C14 16 =A15+0.01
=B15-C15 17 =A16+0.01
=816-C16 18 =A17+0.01
=B17-C17 19 =A18+0.01
=818-C18 20 =A19+0.01
=B19-C19 21 =A20+0.01
=B20-C20 22 =A21+0.01
=B21-C21 23 =A22+0.01
=B22-C22 24 =A23+0.01
=B23-C23 25 =A24+0.01
=B24-C24 26 =A25+0.01
=825-C25 27 =A26+0.01
=826-C26 28 =A27+0.01
=B27-C27 29 =A28+0.01
=B28-C28 30 =A29+0.01
=829-C29 31 =A30+0.01
=830-C30 32 =A31+0.01
=831-C31 33 =A32+0.01
=B32-C32 34 =A33+0.01
=833-C33 35 =A34+0.01
=B34-C34 36 =A35+0.01
=835-C35 37 =A36+0.01
=836-C36 38 =A37+0.01
=837-C37 39 =A38+0.01
=838-C38 40 =A39+0.01
=B39-C39 Attachment A.1 Page A.1-7 of A.1-12 c
D 0.15 Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,t = f1 * (n ro,1+1 - n ro,1) * (1-f bypass)
% flber,removed = If r,l from i=O to i
={(A5-A4))*84*(1-$C$1)
=SUM($C$4:C4)
=((A6-A5))*85*(1-$C$1)
=SUM($C$4:C5)
=((A7-A6))*86*(1-$C$1)
=SUM($C$4:C6)
=((A8-A7))*87*(1-$C$1)
=SUM($C$4:C7)
=((A9-A8))*88*(1-$C$1)
=SUM($C$4:C8)
=((A1 O-A9))*89*(1-$C$1)
=SUM($C$4:C9)
=((A11-A10))*810*(1-$C$1)
=SUM($C$4:C10)
=((A12-A 11 ))*811 *(1-$C$1)
=SUM($C$4:C11)
=((A13-A12))*812*(1-$C$1)
=SUM($C$4:C12)
=((A14-A13))*813*(1-$C$1)
=SUM($C$4:C13)
=((A15-A14))*814*(1-$C$1)
=SUM($C$4:C14)
=((A 16-A15))*815*(1-$C$1)
=SUM($C$4:C15)
=((A17-A 16))*816*(1-$C$1)
=SUM($C$4:C16)
=((A18-A17))*817*(1-$C$1)
=SUM($C$4:C17)
=((A 19-A 18))*818*(1-$C$1)
=SUM($C$4:C18)
=((A20-A 19))*819*(1-$C$1)
=SUM($C$4:C19)
=((A21-A20))*820*(1-$C$1)
=SUM($C$4:C20)
=((A22-A21 ))*821 *(1-$C$1)
=SUM($C$4:C21)
=((A23-A22))*822*( 1-$C$1)
=SUM($C$4:C22)
=((A24-A23))*823*(1-$C$1)
=SUM($C$4:C23)
=((A25-A24))*824*(1-$C$1)
=SUM($C$4:C24)
=((A26-A25))*825*(1-$C$1)
=SUM($C$4:C25)
=((A27-A26))*826*(1-$C$1)
=SUM($C$4:C26)
=((A28-A27H*B27*(1-$C$1)
=SUM($C$4:C27)
=((A29-A28))*828*(1-$C$1)
=SUM($C$4:C28)
=( (A30-A29))*829*( 1-$C$1)
=SUM($C$4:C29)
=((A31-A30))*830*(1-$C$1)
=SUM($C$4:C30)
=((A32-A31 ))*831 *(1-$C$1)
=SUM($C$4:C31)
=((A33-A32))*832*(1-$C$1)
=SUM($C$4:C32)
=((A34-A33))*833*(1-$C$1)
=SUM($C$4:C33)
=((A35-A34))*834*(1-$C$1)
=SUM($C$4:C34)
=((A36-A35))*835*(1-$C$1)
=SUM($C$4:C35)
=((A37-A36))*836*( 1-$C$1)
=SUM($C$4:C36)
=((A38-A37))*837*(1-$C$1)
=SUM($C$4:C37)
=((A39-A38))*838*(1-$C$1)
=SUM($C$4:C38)
=((A40-A39))*839*(1-$C$1)
=SUM($C$4:C39)
=UA41-A40))*840*(1-$C$1)
=SUM($C$4:C40)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
41 =A40+0.01 42 =A41+0.01 43 =A42+0.01 44 =A43+0.01 45 =A44+0.01 46 =A45+0.01 47 =A46+0.01 48 =A47+0.01 49 =A48+0.01 50 =A49+0.01 51 =A50+0.01 52 =A51+0.01 53 =A52+0.01 54 =A53+0.01 55 =A54+0.01 56 =A55+0.01 57 =A56+0.01 58 =A57+0.01 59 =A58+0.01 60 =A59+0.01 61 =A60+0.01 62 =A61+0.01 63 =A62+0.01 64 =A63+0.01 65 =A64+0.01 66 =A65+0.01 67 =A66+0.01 68 =A67+0.01 69 =A68+0.01 70 =A69+0.01 71 =A70+0.01 72 =A71+0.01 73 =A72+0.01 74 =A73+0.01 75 =A74+0.01 76 =A75+0.01 77 =A76+0.01 78 =A77+0.01 79 =A78+0.01 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f I : f 1*1
- f r,1*1 (i ~ 1)
=840-C40
=841-C41
=842-C42
=843-C43
=844-C44
=845-C45
=846-C46
=847-C47
=848-C48
=849-C49
=850-C50
=851-C51
=852-C52
=853-C53
=854-C54
=855-C55
=856-C56
=857-C57
=858-C58
=859-C59
=860-C60
=861-C61
=862-C62
=863-C63
=864-C64
=865-C65
=866-C66
=867-C67
=868-C68
=869-C69
=870-C70
=871-C71
=872-C72
=873-C73
=874-C74
=875-C75
=876-C76
=877-C77
=878-C78 Attachment A.1 Page A.1-8 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) fr,1 =f1 *(nro,1+1 -nro,1) *(1-fbypass)
% flber,removed = J:f r,I from i=O to i
=UA42-A41 ))*841 *(1-$C$1 l
=SUM($C$4:C41)
=((A43-A42))*842*(1-$C$1)
=SUM($C$4:C42)
=((A44-A43))*843*(1-$C$1)
=SUM($C$4:C43)
=((A45-A44 ))*844*(1-$C$1)
=SUM($C$4:C44)
=( (A46-A45) )*845*( 1-$C$1 )
=SUM($C$4:C45)
=UA47-A46))*846*(1-$C$1)
=SUM($C$4:C46)
=((A48-A47))*847*(1-$C$1)
=SUM($C$4:C47)
=((A49-A48))*848*(1-$C$1)
=SUM($C$4:C48)
=((A50-A49))*849*(1-$C$1)
=SUM($C$4:C49)
=((A51-A50))*850*(1-$C$1)
=SUM($C$4:C50)
=UA52-A51 ))*851 *(1-$C$1)
=SUM($C$4:C51)
=((A53-A52))*852*(1-$C$1)
=SUM($C$4:C52)
=((A54-A53))*853*(1-$C$1)
=SUM($C$4:C53)
=UA55-A54))*854*(1-$C$1)
=SUM($C$4:C54 l
=((A56-A55))*855*(1-$C$1)
=SUM($C$4:C55)
=UA57-A56))*856*(1-$C$1 l
=SUM($C$4:C56)
=((A58-A57))*857*{1-$C$1)
=SUM($C$4:C57)
=((A59-A58))*858*(1-$C$1)
=SUM{$C$4:C58)
=( (A60-A59) )*859*( 1-$C$1 )
=SUM($C$4:C59)
=((A61-A60))*860*{1-$C$1)
=SUM($C$4:C60)
=((A62-A61 ))*861 *(1-$C$1)
=SUM($C$4:C61)
=((A63-A62)}*862*(1-$C$1)
=SUM($C$4:C62)
=((A64-A63))*863*(1-$C$1)
=SUM($C$4:C63)
=((A65-A64))*864*(1-$C$1)
=SUM1$C$4:C64)
=((A66-A65)}*865*(1-$C$1)
=SUM($C$4:C65)
=((A67-A66))*866*( 1-$C$1)
=SUM($C$4:C66)
=((A68-A67))*867*(1-$C$1)
=SUM($C$4:C67)
=((A69-A68))*868*(1-$C$1)
=SUM($C$4:C68)
=((A70-A69)}*869*(1-$C$1)
=SUM($C$4:C69)
=((A71-A70))*870*(1-$C$1)
=SUM($C$4:C70)
=((A72-A71 ))*871 *(1-$C$1)
=SUM{$C$4:C71)
=((A73-A72))*872*(1-$C$1)
=SUM($C$4:C72)
=((A7 4-A73))*873*(1-$C$1)
=SUM($C$4:C73)
=((A75-A7 4))*874*(1-$C$1)
=SUM($C$4:C74)
=((A76-A75))*875*(1-$C$1)
=SUM($C$4:C75)
=((A77-A76))*876*(1-$C$1)
=SUM($C$4:C76)
=((A78-A77))*877*(1-$C$1)
=SUM($C$4:C77l
=((A79-A78))*878*(1-$C$1)
=SUM($C$4:C78)
=((A80-A79ll*B79*(1-$C$1 l
=SUM($C$4:C79)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
80 =A79+0.01 81 =A80+0.01 82 =A81+0.01 83 =A82+0.01 84 =A83+0.01 85 =A84+0.01 86 =A85+0.01 87 =A86+0.01 88 =A87+0.01 89 =A88+0.01 90 =A89+0.01 91 =A90+0.01 92 =A91+0.01 93 =A92+0.01 94 =A93+0.01 95 =A94+0.01 96 =A95+0.01 97 =A96+0.01 98 =A97+0.01 99 =A98+0.01 100 =A99+0.01 101 =A100+0.01 102 =A101+0.01 103 =A102+0.01 104 =A103+0.01 105 =A104+0.01 106 =A105+0.01 107 =A106+0.01 108 =A107+0.01 109 =A108+0.01 110 =A109+0.01 111 =A110+0.01 112 =A111+0.01 113 =A112+0.01 114 =A113+0.01 115 =A114+0.01 116 =A115+0.01 117 =A116+0.01 118 =A117+0.01 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) fo = 1.0 f, = f1.1 - f r,/*1 (i 2?: 1)
=879-C79
=880-C80
=881-C81
=882-C82
=883-C83
=884-C84
=885-C85
=886-C86
=887-C87
=888-C88
=889-C89
=890-C90
=891-C91
=892-C92
=893-C93
=894-C94
=895-C95
=896-C96
=897-C97
=898-C98
=899-C99
=8100-C100
=8101-C101
=8102-C102
=8103-C103
=8104-C104
=8105-C105
=8106-C106
=8107-C107
=8108-C108
=8109-C109
=8110-C110
=8111-C111
=8112-C112
=8113-C113
=8114-C114
=8115-C115
=8116-C116
=8117-C117 Attachment A. 1 Page A.1-9 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,I = f, * (n ro,1+1 - n ro,1) * (1-f bypass)
% nber,removed =,Ef r,I from i=O to i
=((A81-A80))*880*(1-$C$1)
=SUM($C$4:C80)
=((A82-A81 ))*881 *(1-$C$1)
=SUM($C$4:C81)
=((A83-A82))*882*(1-$C$1)
=SUM($C$4:C82)
=((A84-A83))*883*(1-$C$1)
=SUM($C$4:C83)
=((A85-A84))*884*(1-$C$1)
=SUM($C$4:C84)
=((A86-A85))*885*(1-$C$1)
=SUM($C$4:C85)
=((A87-A86))*886*(1-$C$1)
=SUM($C$4:C86)
=((A88-A87))*887*(1-$C$1)
=SUM($C$4:C87)
=((A89-A88))*888*(1-$C$1)
=SUM($C$4:C88)
=((A90-A89))*889*{1-$C$1)
=SUM($C$4:C89)
=((A91-A90))*890*(1-$C$1)
=SUM($C$4:C90)
=((A92-A91 ))*891 *(1-$C$1)
=SUM($C$4:C91)
=((A93-A92))*892*(1-$C$1)
=SUM($C$4:C92)
=((A94-A93))*893*(1-$C$1)
=SUM($C$4:C93)
=((A95-A94))*894*(1-$C$1)
=SUM($C$4:C94)
=((A96-A95))*895*(1-$C$1)
=SUM($C$4:C95)
=((A97-A96))*896*(1-$C$1)
=SUM($C$4:C96)
=((A98-A97))*897*(1-$C$1)
=SUM($C$4:C97)
=( (A99-A98) )*898*( 1-$C$1)
=SUM($C$4:C98)
=((A 1 OO-A99) )*899*(1-$C$1)
=SUM($C$4:C99)
=((A101-A 100))*8100*(1-$C$1)
=SUM($C$4:C100)
=((A102-A101))*8101 *(1-$C$1)
=SUM($C$4:C101)
=((A 103-A 102))*8102*(1-$C$1)
=SUM($C$4:C102)
=((A104-A103))*8103*(1-$C$1)
=SUMf$C$4:C103)
=((A105-A104))*8104*(1-$C$1)
=SUM($C$4:C104)
=((A 106-A 105))*8105*(1-$C$1)
=SUM($C$4:C105)
=((A107-A 106))*8106*(1-$C$1)
=SUM($C$4:C106)
=((A 108-A107))*8107*(1-$C$1)
=SUM($C$4:C107)
=((A 109-A 108))*8108*(1-$C$1)
=SUM($C$4:C108)
=((A 110-A 109))*8109*(1-$C$1)
=SUM($C$4:C109)
=((A111-A110))*8110*(1-$C$1)
=SUM($C$4:C110)
=((A112-A111))*8111*(1-$C$1)
=SUM($C$4:C 111)
=((A113-A112))*8112*(1-$C$1)
=SUM($C$4:C112)
=((A 114-A113))*8113*(1-$C$1)
=SUM($C$4:C113)
=((A115-A114))*8114*(1-$C$1)
=SUM($C$4:C114)
=((A116-A115))*8115*(1-$C$1)
=SUM($C$4:C115)
=((A117-A116))*8116*(1-$C$1)
=SUMf$C$4:C116)
=((A 118-A 117))*8117*(1-$C$1)
=SUM($C$4:C117)
=((A119-A118))*8118*(1-$C$1)
=SUM($C$4:C118)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers Oro 3
119 =A118+0.01 120 =A119+0.01 121 =A120+0.01 122 =A121+0.01 123 =A122+0.01 124 =A123+0.01 125 =A124+0.01 126 =A125+0.01 127 =A126+0.01 128 =A127+0.01 129 =A128+0.01 130 =A129+0.01 131 =A130+0.01 132 =A131+0.01 133 =A132+0.01 134 =A133+0.01 135 =A134+0.01 136 =A135+0.01 137 =A136+0.01 138 =A137+0.01 139 =A138+0.01 140 =A139+0.01 141 =A140+0.01 142 =A141+0.01 143 =A142+0.01 144 =A143+0.01 145 =A144+0.01 146 =A145+0.01 147 =A146+0.01 148 =A147+0.01 149 =A148+0.01 150 =A149+0.01 151 =A150+0.01 152 =A151+0.01 153 =A152+0.01 154 =A153+0.01 155 =A154+0.02 156 =A155+0.02 157 =A156+0.02 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f I : f 1-1
- f r,1-1 (i i2:: 1)
=8118-C118
=8119-C119
=8120-C120
=8121-C121
=8122-C122
=8123-C123
=8124-C124
=8125-C125
=8126-C126
=8127-C127
=8128-C128
=8129-C129
=8130-C130
=8131-C131
=8132-C132
=8133-C133
=8134-C134
=8135-C135
=8136-C136
=8137-C137
=8138-C138
=8139-C139
=8140-C140
=8141-C141
=8142-C142
=8143-C143
=8144-C144
=8145-C145
=8146-C146
=8147-C147
=8148-C148
=8149-C149
=8150-C150
=8151-C151
=8152-C152
=8153-C153
=8154-C154
=8155-C155
=8156-C156 Attachment A.1 Page A.1-1 O of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) fr,1 =f1 "(nro,1+1 -nro,1)"(1-fbypassJ
% nber,removed = If r,t from i=O to i
=<<A120-A119))*8119*(1-$C$1 l
=SUM($C$4:C119)
=((A 121-A 120) )*8120*(1-$C$1)
=SUM($C$4:C120)
=((A 122-A121))*8121 *(1-$C$1)
=SUM($C$4:C121)
=((A 123-A122))*8122*(1-$C$1 l
=SUM($C$4:C122)
=((A 124-A123))*8123*(1-$C$1)
=SUM($C$4:C123)
=((A125-A 124))*8124*(1-$C$1)
=SUM($C$4:C124)
=((A 126-A125))*8125*(1-$C$1 l
=SUM($C$4:C125)
=((A127-A 126))*8126*(1-$C$1)
=SUM($C$4:C126)
=((A128-A 127))*8127*(1-$C$1 l
=SUM($C$4:C127)
=((A129-A 128))*8128*(1-$C$1)
=SUM($C$4:C128)
=<<A130-A129))*8129*(1-$C$1)
=SUM($C$4:C129)
=((A 131-A 130))*8130*(1-$C$1)
=SUM($C$4:C130)
=((A 132-A 131))*8131 *(1-$C$1)
=SUM($C$4:C131)
=((A 133-A 132))*8132*( 1-$C$1 l
=SUM($C$4:C132)
=((A134-A133))*8133*(1-$C$1)
=SUM($C$4:C133)
=<<A135-A 134))*8134*(1-$C$1)
=SUM($C$4:C134)
=((A 136-A 135))*8135*(1-$C$1)
=SUM($C$4: C 135)
=((A 137-A 136))*8136*(1-$C$1)
=SUM($C$4:C136)
=((A138-A 137))*8137*(1-$C$1)
=SUM($C$4:C137)
=((A139-A 138))*8138*(1-$C$1)
=SUM($C$4:C138)
=((A 140-A139))*8139*(1-$C$1)
=SUM($C$4:C139)
=((A 141-A 140))*8140*(1-$C$1)
=SUM($C$4:C140)
=((A 142-A 141))*8141*(1-$C$1)
=SUM($C$4:C141)
=((A 143-A142))*8142*(1-$C$1)
=SUM($C$4:C142)
=((A144-A 143))*8143*(1-$C$1)
=SUM($C$4:C143)
=<<A 145-A144))*8144*(1-$C$1)
=SUM($C$4:C144)
=((A 146-A 145))*8145*(1-$C$1 l
=SUM($C$4:C145)
=((A 147-A 146))*8146*(1-$C$1)
=SUM($C$4:C146)
=((A 148-A147))*8147*(1-$C$1)
=SUM($C$4:C147)
=((A149-A148))*8148*(1-$C$1 l
=SUM($C$4:C148)
=((A150-A149))*8149*(1-$C$1)
=SUM($C$4:C149)
=((A 151-A150))*8150*(1-$C$1 l
=SUM($C$4:C150)
=((A 152-A 151))*8151 *(1-$C$1)
=SUM($C$4:C151)
=((A153-A152))*8152*(1-$C$1)
=SUM($C$4:C152)
=((A 154-A153))*8153*(1-$C$1 l
=SUM($C$4:C153)
=((A155-A 154))*8154*(1-$C$1)
=SUM($C$4:C154)
=((A156-A155))*8155*(1-$C$1 l
=SUM($C$4:C155)
=((A157-A 156))*8156*(1-$C$1)
=SUM($C$4:C156)
=<<A 158-A 157))*8157*(1-$C$1)
=SUM($C$4:C157)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
158 =A157+0.02 159 =A158+0.02 160 =A159+0.02 161 =A160+0.02 162 =A161+0.02 163 =A162+0.02 164 =A163+0.02 165 =A164+0.02 166 =A165+0.02 167 =A166+0.02 168 =A167+0.02 169 =A168+0.02 170 =A169+0.02 171 =A170+0.02 172 =A171+0.02 173 =A172+0.02 174 =A173+0.02 175 =A174+0.02 176 =A175+0.02 177 =A176+0.02 178 =A177+0.02 179 =A178+0.02 180 =A179+0.02 181 =A180+0.02 182 =A181+0.02 183 =A182+0.02 184 =A183+0.02 185 =A184+0.02 186 =A185+0.02 187 =A186+0.02 188 =A187+0.02 189 =A188+0.02 190 =A189+0.02 191 =A190+0.02 192 =A191+0.02 193 =A192+0.02 194 =A193+0.02 195 =A194+0.02 196 =A195+0.02 8
Fraction of Fiber Mass In Pool (Eq. 4 & 12) f 0 = 1.0 f, = f1.1 - f r,1-1 (i ~ 1)
=8157-C157
=8158-C158
=8159-C159
=8160-C160
=8161-C161
=8162-C162
=8163-C163
=8164-C164
=8165-C165
=8166-C166
=8167-C167
=8168-C168
=8169-C169
=8170-C170
=8171-C171
=8172-C172
=8173-C173
=8174-C174
=8175-C175
=8176-C176
=8177-C177
=8178-C178
=8179-C179
=8180-C180
=8181-C181
=8182-C182
=8183-C183
=8184-C184
=8185-C185
=8186-C186
=8187-C187
=8188-C188
=8189-C189
=8190-C190
=8191-C191
=8192-C192
=8193-C193
=8194-C194
=8195-C195 Attachment A.1 PageA.1-11 ofA.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 10)
From Pool (Eq. 13) f r,1 = f1 * (n ro,1+1
- n ro,iJ * (1-f bypass)
% nber,removed = J:f r,I from i=O to i
=((A 159-A158))*8158*(1-$C$1)
=SUM($C$4:C158)
=((A 160-A159))*8159*(1-$C$1)
=SUM($C$4:C159)
=<<A 161-A 160))*8160*(1-$C$1)
=SUM($C$4:C160)
=((A 162-A161 ))*8161*(1-$C$1)
=SUM($C$4:C161)
=((A 163-A 162))*8162*(1-$C$1)
=SUM($C$4:C162)
=((A 164-A163))*8163*(1-$C$1)
=SUM($C$4:C163)
=((A 165-A164))*8164*(1-$C$1)
=SUM($C$4:C164)
=((A 166-A165))*8165*(1-$C$1)
=SUM($C$4:C165)
=((A 167-A 166))*8166*(1-$C$1)
=SUM($C$4:C166)
=((A 168-A167))*8167*(1-$C$1)
=SUM($C$4:C167)
=((A 169-A168))*8168*(1-$C$1)
=SUM($C$4:C168)
=((A 170-A 169))*8169*(1-$C$1)
=SUM($C$4:C169)
=<<A 171-A 170))*8170*(1-$C$1)
=SUM($C$4:C170)
=((A 172-A 171))*8171*(1-$C$1)
=SUM($C$4:C171)
=((A 173-A172))*8172*(1-$C$1)
=SUM($C$4:C172)
=((A 174-A 173))*8173*(1-$C$1)
=SUM($C$4:C173)
=((A 175-A 174))*8174*(1-$C$1)
=SUM($C$4:C174)
=<<A176-A175))*8175*(1-$C$1)
=SUM($C$4:C175)
=((A 177-A 176))*8176*(1-$C$1)
=SUM($C$4:C176)
=((A 178-A 177))*8177*(1-$C$1)
=SUM($C$4:C177)
=((A 179-A 178))*8178*(1-$C$1)
=SUM($C$4:C178)
=((A 180-A 179))*8179*(1-$C$1)
=SUM($C$4:C179)
=((A 181-A 180))*8180*(1-$C$1)
=SUMC$C$4:C180)
=((A 182-A181))*8181*(1-$C$1)
=SUM($C$4:C181)
=((A 183-A 182))*8182*(1-$C$1)
=SUM($C$4:C182)
=((A 184-A 183))*8183*(1-$C$1)
=SUM($C$4:C183)
=((A 185-A 184))*8184*(1-$C$1)
=SUM($C$4:C184)
=((A 186-A 185))*8185*(1-$C$1)
=SUM($C$4:C185)
=((A 187-A 186))*8186*(1-$C$1)
=SUM($C$4:C186)
=((A 188-A 187))*8187*(1-$C$1)
=SUM($C$4:C187)
=((A 189-A 188))*8188*(1-$C$1)
=SUMC$C$4:C188)
=((A 190-A 189))*8189*(1-$C$1)
=SUM($C$4:C189)
=((A 191-A 190))*8190*11-$C$1)
=SUM($C$4:C190)
=((A192-A191))*8191*(1-$C$1)
=SUM($C$4:C191)
=((A 193-A 192))*8192*(1-$C$1)
=SUM($C$4:C192)
=((A 194-A193))*8193*(1-$C$1)
=SUM($C$4:C193)
=((A 195-A 194))*8194*(1-$C$1)
=SUM($C$4:C194)
=((A 196-A195))*8195*(1-$C$1)
=SUM($C$4:C195)
=((A 197-A 196))*8196*(1-$C$1)
=SUM($C$4:C196)
Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
Number of Pool Turnovers nro 3
197 =A196+0.02 198 =A197+0.02 199 =A198+0.02 200 =A199+0.02 201 =A200+0.02 202 =A201+0.02 203 =A202+0.02 204 =A203+0.02 205 =A204+0.02 206 =A205+0.02 207 =A206+0.02 208 =A207+0.02 209 =A208+0.02 210 =A209+0.02 211 =A210+0.02 212 =A211+0.02 213 =A212+0.02 214 =A213+0.02 215 =A214+0.02 216 =A215+0.02 217 =A216+0.02 218 =A217+0.02 219 =A218+0.02 220 =A219+0.02 221 =A220+0.02 222 =A221+0.02 223 =A222+0.02 224 =A223+0.02 225 =A224+0.02 226 =A225+0.02 227 =A226+0.02 228 =A227+0.02 229 =A228+0.02 230 =A229+0.02 8
Fraction of Fiber Mass in Pool (Eq. 4 & 12) f 0 = 1.0 f1 = f1.1
- fr,1-1 (i 01!: 1)
=8196-C196
=8197-C197
=8198-C198
=8199-C199
=8200-C200
=8201-C201
=B202-C202
=8203-C203
=8204-C204
=8205-C205
=8206-C206
=8207-C207
=8208-C208
=8209-C209
=8210-C210
=8211-C211
=8212-C212
=8213-C213
=8214-C214
=8215-C215
=8216-C216
=8217-C217
=8218-C218
=8219-C219
=8220-C220
=8221-C221
=8222-C222
=8223-C223
=8224-C224
=B225-C225
=8226-C226
=8227-C227
=8228-C228 Attachment A.1 Page A.1-12 of A.1-12 c
D Fiber Mass Fraction Percent of Fiber Removed Removed from Pool (Eq. 1 O)
From Pool (Eq. 13) f,,, = f, *(nro,1+1
- nro,1) * (1-fbypassJ
% nber,removed =,Ef r,I from i=O to i
=((A 198-A 197))*8197*(1-$C$1)
=SUM($C$4:C197)
=((A 199-A 198))*8198*(1-$C$1)
=SUM{$C$4:C198)
=((A200-A 199))*8199*(1-$C$1)
=SUM($C$4:C199)
=< (A201-A200))*8200*(1-$C$1)
=SUM($C$4:C200)
=((A202-A201 ))*8201 *(1-$C$1)
=SUM($C$4:C201)
=((A203-A202))*8202*(1-$C$1)
=SUM($C$4:C202)
=((A204-A203))*8203*(1-$C$1)
=SUM($C$4:C203)
=( (A205-A204) )*8204*(1-$C$1)
=SUM($C$4:C204)
=( (A206-A205) )*8205*(1-$C$1)
=SUM($C$4:C205)
=((A207-A206))*8206*(1-$C$1)
=SUM($C$4:C206)
=( (A208-A207))*8207*( 1-$C$1)
=SUM($C$4:C207)
=( (A209-A208) )*8208*( 1-$C$1 l
=SUM($C$4:C208)
=((A21 O-A209) )*8209*{1-$C$1)
=SUM($C$4:C209)
=((A211-A210))*8210*(1-$C$1)
=SUM($C$4:C210)
=((A212-A211 ))*8211 *(1-$C$1 l
=SUM($C$4:C211)
=((A213-A212))*8212*(1-$C$1)
=SUM($C$4:C212)
=((A214-A213))*8213*(1-$C$1)
=SUM($C$4:C213}
=((A215-A214})*8214*(1-$C$1)
=SUM($C$4:C214)
=({A216-A215))*8215*(1-$C$1)
=SUM($C$4:C215)
=((A217-A216))*B216*(1-$C$1)
=SUM($C$4:C216l
=((A218-A217))*8217*(1-$C$1}
=SUM($C$4:C217)
=((A219-A218))*8218*(1-$C$1)
=SUM($C$4:C218}
=((A220-A219))*8219*(1-$C$1)
=SUM($C$4:C219l
=((A221-A220))*8220*(1-$C$1)
=SUM($C$4:C220)
=((A222-A221 ))*8221 *(1-$C$1 l
=SUM($C$4:C221)
=((A223-A222))*8222*(1-$C$1)
=SUM($C$4:C222)
=((A224-A223))*8223*(1-$C$1)
=SUM($C$4:C223)
=((A225-A224))*8224*(1-$C$1)
=SUM($C$4:C224l
=( (A226-A225))*8225*( 1-$C$1)
=SUM($C$4:C225)
=((A227-A226))*8226*(1-$C$1l
=SUM($C$4:C226l
=((A228-A227}}*8227*(1-$C$1)
=SUM($C$4:C227)
=((A229-A228) )*8228*(1-$C$1)
=SUM($C$4:C228}
=( (A230-A229))*8229*(1-$C$1 l
=SUM($C$4:C229l Att A.1 (Eqs)
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 ECCS Switchover Time 3 CS Switchover Time 4 ics - tECCS 5 RH Flow= Recirc Flow 6 Number of Trains 7 Flow per Strainer 8 Volume on Floor at ~ccs 9 Volume on Floor at tcs 10 Average Volume on Floor 11 Average Volume on Floor 12 Number of Turnovers 13 14 Calculation I Case 15 ECCS Switchover Time 16 CS Switchover Time 17 tcs - tEccs 18 RH Flow = Recirc Flow 19 Number of Trains 20 Flow per Strainer 21 Volume on Floor at tEccs 22 Volume on Floor at tcs 23 Average Volume on Floor 24 Average Volume on Floor 25 Number of Turnovers 26 B
c D
Sl-90-01 Att. B Case 1 OSG tEccs 999 sec tcs 2,736 sec
.1.t 1,737 sec QRH 4,557 gpm ntrain 1
Ostr 4,557 gpm VEccs 9,769 ft3 Vcs 25,787 ft3 Vavg 17,778 ft3 Vavg 132,997 gal nro 0.99 Sl-90-01 Att. B Case 2 OSG tEccs 1, 112 sec tcs 2,849 sec
.1.t 1,737 sec QRH 1,663 gpm ntrain 1
Ostr 1,663 gpm VEccs 9,874 ft3 Vcs 25,601 ft3 Vavg 17,738 ft3 Vavg 132,694 gal nro 0.36 Attachment A.2 Page A.2-1 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01 Att. B. Case 1 RSG
---~"""
ECCS Switchover Time tECCS 999 sec CS Switchover Time tcs 2,736 sec tcs - tEccs
.1.t 1,737 sec RH Flow = Recirc Flow QRH 4,557 gpm Number of Trains n1rain 1
Flow per Strainer Ostr 4,557 gpm Volume on Floor at tEccs VECCS 9,823 ft3 Volume on Floor at tcs Vcs 26,350 ft3 Average Volume on Floor Vavg 18,087 ft3 Average Volume on Floor Vavg 135,305 gal Number of Turnovers nro 0.98 Calculation I Case Sl-90-01. Att. B. Case 2 RSG ECCS Switchover Time tECCS 1, 112 sec CS Switchover Time tcs 2,849 sec ics - tECCS Lit 1,737 sec RH Flow = Recirc Flow QRH 1,663 gpm Number of Trains ntrain 1
Flow per Strainer Ostr 1,663 gpm Volume on Floor at tEccs VECCS 9,865 ft3 Volume on Floor at tcs Vcs 26,188 ft3 Average Volume on Floor Vavg 18,027 ft3 Average Volume on Floor Vavg 134,856 gal Number of Turnovers nro 0.36 TOs Sl-90-01
Calculation 2014-04466 Revision 1 A
27 Calculation I Case 28 ECCS Switchover Time 29 CS Switchover Time 30 tes - tEees 31 RH Flow = Recirc Flow 32 Number of Trains 33 Flow per Strainer 34 Volume on Floor at tEees 35 Volume on Floor at tcs 36 Average Volume on Floor 37 Average Volume on Floor 38 Number of Turnovers 39 40 Calculation I Case 41 ECCS Switchover Time 42 CS Switchover Time 43 ics - tEees 44 RH Flow = Recirc Flow 45 Number of Trains 46 Flow per Strainer 47 Volume on Floor at tEees 48 Volume on Floor at tcs 49 Average Volume on Floor 50 Average Volume on Floor 51 Number of Turnovers B
c D
Sl-90-01 Att. B Case 3 OSG tEees 1,029 sec tes 2,766 sec At 1,737 sec QRH 4,557 gpm ntrain 1
Ostr 4,557 gpm VEees 9,676 ft3 Yes 25,739 ft3 Vavg 17,708 ft3 Vavg 132,470 gal nrn 1.00 Sl-90-01 Att. B. Case 4 OSG tEees 574 sec tes 1,490 sec At 916 sec QRH 7,797 gpm ntrain 2
Ostr 3,899 gpm VEees 11, 125 ft3 Yes 24, 109 ft3 Vavg 17,617 ft3 Vavg 131,793 gal nrn 0.90 Attachment A.2 Page A.2-2 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01 Att. B. Case 3 RSG ECCS Switchover Time tEees 1,029 sec CS Switchover Time tes 2,766 sec ics - tEees At 1,737 sec RH Flow= Recirc Flow QRH 4,557 gpm Number of Trains n1rain 1
Flow per Strainer Qstr 4,557 gpm Volume on Floor at tEees VEees 9,728 ft3 Volume on Floor at tes Yes 26,308 ft3 Average Volume on Floor Vavg 18,018 ft3 Average Volume on Floor Vavg 134,793 gal Number of Turnovers nrn 0.98 Calculation I Case Sl-90-01. Att. B. Case 4 RSG ECCS Switchover Time tEees 574 sec CS Switchover Time tes 1,490 sec ics - tEees At 916 sec RH Flow = Recirc Flow QRH 7,797 gpm Number of Trains ntrain 2
Flow per Strainer Ostr 3,899 gpm Volume on Floor at tEees VEees 11,317 ft3 Volume on Floor at tes Yes 25,338 ft3 Average Volume on Floor Vavg 18,328 ft3 Average Volume on Floor Vavg 137,108 gal Number of Turnovers nrn 0.87 TOs Sl-90-01
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 ECCS Switchover Time 3 CS Switchover Time 4 tcs - tEccs 5 RH Flow = Recirc Flow 6 Number of Trains 7 Flow per Strainer 8 Volume on Floor at tEccs 9 Volume on Floor at tcs 10 Average Volume on Floor 11 Average Volume on Floor 12 Number of Turnovers 13 14 Calculation I Case 15 ECCS Switchover Time 16 CS Switchover Time 17 ics - tEccs 18 RH Flow= Recirc Flow 19 Number of Trains 20 Flow per Strainer 21 Volume on Floor at ~ccs 22 Volume on Floor at tcs 23 Average Volume on Floor 24 Average Volume on Floor 25 Number of Turnovers 26 B
c D
Sl-90-01, Att. B, Case 1 OSG tEccs 999 sec tcs 2736 sec Lit
=C3-C2 sec QRH 4557 gpm ntrain 1
Ostr
=C5/C6 gpm VEccs 9769 ft3 Vcs 25787 ft3 Vavg
=(C8+C9)/2 ft3 Vavg
=C10*7.481 gal nm
=C5*C4/60/C 11 Sl-90-01 Att. B, Case 2 OSG tEccs 1112 sec ics 2849 sec Lit
=C16-C15 sec QRH 1663 gpm ntrain 1
Ostr
=C18/C19 gpm VECCS 9874 ft3 Vcs 25601 ft3 Vavg
=(C21 +C22)/2 ft3 Vavg
=C23*7.481 gal nm
=C18*C17/60/C24 Attachment A.2 Page A.2-3 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01, Att. B, Case 1 RSG ECCS Switchover Time tEccs 999 sec CS Switchover Time tcs 2736 sec tcs - tEccs Lit
=H3-H2 sec RH Flow= Recirc Flow QRH 4557 gpm Number of Trains ntrain 1
Flow per Strainer Ostr
=H5/H6 gpm Volume on Floor at tEccs VECCS 9823 ft3 Volume on Floor at tcs Vcs 26350 ft3 Average Volume on Floor Vavg
=(H8+H9)/2 ft3 Average Volume on Floor Vavg
=H10*7.481 gal Number of Turnovers nTo
=H5*H4/60/H 11 Calculation I Case Sl-90-01, Att. B, Case 2 RSG ECCS Switchover Time tEccs 1112 sec CS Switchover Time tcs 2849 sec tcs - tECCS Lit
=H16-H15 sec RH Flow = Recirc Flow QRH 1663 gpm Number of Trains ntrain 1
Flow per Strainer Ostr
=H18/H19 gpm Volume on Floor at tEccs VECCS 9865 ft3 Volume on Floor at tcs Vcs 26188 ft3 Average Volume on Floor Vavg
=(H21 +H22)/2 ft3 Average Volume on Floor Vavg
=H23*7.481 gal Number of Turnovers nm
=H18*H17/60/H24 TOs Sl-90-01 (Eqs)
Calculation 2014-04466 Revision 1 A
27 Calculation I Case 28 ECCS Switchover Time 29 CS Switchover Time 30 tcs - tECCS 31 RH Flow = Recirc Flow 32 Number of Trains 33 Flow per Strainer 34 Volume on Floor at ~ccs 35 Volume on Floor at tcs 36 Average Volume on Floor 37 Average Volume on Floor 38 Number of Turnovers 39 40 Calculation I Case 41 ECCS Switchover Time 42 CS Switchover Time 43 tcs - tEccs 44 RH Flow = Recirc Flow 45 Number of Trains 46 Flow per Strainer 47 Volume on Floor at tEccs 48 Volume on Floor at tcs 49 Average Volume on Floor 50 Average Volume on Floor 51 Number of Turnovers B
c D
Sl-90-01, Att. B, Case 3 OSG tEccs 1029 sec tcs 2766 sec
.!lt
=C29-C28 sec QRH 4557 gpm ntrain 1
Os1r
=C31/C32 gpm VECCS 9676 ft3 Vcs 25739 ft3 Vavg
=(C34+C35)/2 ft3 Vavg
=C36*7.481 gal nro
=C31 *C30/60/C37 Sl-90-01, Att. B Case 4 OSG tEccs 574 sec tcs 1490 sec dt
=C42-C41 sec QRH 7797 gpm ntrain 2
Os1r
=C44/C45 gpm VEccs 11125 ft3 Vcs 24109 ft3 Vavg
=(C47+C48)/2 ft3 Vavg
=C49*7.481 gal nro
=C44*C43/60/C50 Attachment A.2 Page A.2-4 of A.2-12 E
F G
H I
Calculation I Case Sl-90-01, Att. B, Case 3 RSG ECCS Switchover Time tEccs 1029 sec CS Switchover Time tcs 2766 sec tcs - tEccs dt
=H29-H28 sec RH Flow= Recirc Flow QRH 4557 gpm Number of Trains ntrain 1
Flow per Strainer Qstr
=H31/H32 gpm Volume on Floor at tEccs VECCS 9728 ft3 Volume on Floor at tcs Vcs 26308 ft3 Average Volume on Floor Vavg
=(H34+H35)/2 ft3 Average Volume on Floor Vavg
=H36*7.481 gal Number of Turnovers nro
=H31 *H30/60/H37 Calculation I Case Sl-90-01, Att. B, Case 4 RSG ECCS Switchover Time tECCS 574 sec CS Switchover Time tcs 1490 sec tcs - tECCS
.!lt
=H42-H41 sec RH Flow= Recirc Flow QRH 7797 gpm Number of Trains ntrain 2
Flow per Strainer Ostr
=H44/H45 gpm Volume on Floor at tEccs VECCS 11317 ft3 Volume on Floor at tcs Vcs 25338 ft3 Average Volume on Floor Vavg
=(H47+H48)/2 ft3 Average Volume on Floor Vavg
=H49*7.481 gal Number of Turnovers nro
=H44*H43/60/H50 TOs Sl-90-01 (Eqs)
Calculation 2014-04466 Revision 1 A
1 Calculation I Case 2 EGGS Switchover Initiation Time 3 RH Pumps Switched Over 4 RWST Volume Remaining at IRH,f RWST Outflow fort <': tRH.f Assuming RWST to RH 5 Pump Suction Isolation Valves Close 6 RWST Level at CS Switchover Initiation 7 RWST Feet oer % Level 8 RWST Gallons oer Foot 9 RWST Volume at CS Switchover Initiation 10 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 11 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 12 Switchover Initiation 13 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 14 Switchover Initiation 15 RH Pump Flow 16 Number of Trains in Recirc 17 Flow per Strainer 18 Volume on Floor at 4:ccs 19 Volume on Floor at -1560 sec in ATD-0111 20 Approximate Volume on Floor at tcs.;
21 Average Volume on Floor 22 Average Volume on Floor 23 Number of Turnovers 24 Attachment A.2 Page A.2-5 of A.2-12 B
c D
E ATD-0111 Ac 1>. H. BRW 1 RSG 4:ccs 928.7 sec Sht 1 of ATD-0111 Appendix H IRH,f 1,156.7 sec Sht 1 of ATD-0111 Appendix H VRWST,tRH,f 114,151 gal Sht 1 of ATD-0111 Appendix H QRWST,tRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FoP 0.54833 ttl°lo SITH-1, P. 11 GpF 8,351.6,Qal/ft SITH-1, p.14 VRWST,!CS,i 54,953.2 gal
= L0-3
- FpP
- GpF VRWST,!CS,i '
7,346.7 ft3
= V RWST.tCS.i / 7.48 galfft3 VtRH,f-tCS,i 59,197.8 gal
= VRWST.tRH,f - VRWST,tCS,i imH,f-ICS,i 405.8 sec
= (V1RH.r-1cs,; I QRwsT,tRH,t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion ics,;
1,562.5 sec
= tRH,f + tRH,f-!CS,i L\\t 633.8 sec
= ics,; - tEccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix H Ostr 3,899 gpm
= QRH I ntrain VECCS 32,589 ft3 Sht 12 of A TD-0111 Appendix H V1550 59,798 ft3 Sht 12 of ATD-0111 Appendix H Vcs 52,451 ft3
= V156o - VRwsT.tes;'
Vavg 42,520 ft3
= (VEccs + Vcs) / 2 Vavg '
318,051 gal
= Va\\/O
- 7.48 gal/ft3 nro 0.26
= QRH
- L\\tl (60 sec/min
- V avg')
TOs ATD-0111
Calculation 2014-04466 Revision 1 A
25 Calculation I Case 26 ECCS Switchover Initiation Time 27 RH Pumps Switched Over 28 RWST Volume Remaining at tRH.f RWST Outflow fort ~ tRH,f Assuming RWST to RH 29 Pump Suction Isolation Valves Close 30 RWST Level at CS Switchover Initiation 31 RWST Feet per % Level 32 RWST Gallons per Foot 33 RWST Volume at CS Switchover Initiation 34 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 35 Comoletion and CS Switchover Initiation Time between RH Switchover Completion and CS 36 Switchover Initiation 37 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 38 Switchover Initiation 39 RH Pump Flow 40 Number of Trains in Recirc 41 Flow per Strainer 42 Volume on Floor at ~ccs 43 Volume on Floor at -1560 sec in ATD-0111 44 Approximate Volume on Floor at tcs,;
45 Average Volume on Floor 46 Average Volume on Floor 47 Number of Turnovers 48 Attachment A.2 Page A.2-6 of A.2-12 B
c D
~ccs 928.7 sec Sht 1 of ATD-0111 Appendix I
~H,f 1,156.7 sec Sht 1 of ATD-0111 Appendix I VRwsT.tRH.f 114,151 gal Sht 1 of ATD-0111 Appendix I QRWST,IRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, o. 11 GpF 8,351.6 Qallft SITH-1, p. 14 VRWST,tCS,i 54,953.2 gal
= L0-3
- FpP
- GpF v
RWST,tCS,i 7,346.7 ft3
= V Rwsr.tcs ; I 7.48 gallft3 VtRH,f-tCS,i 59,197.8 gal
= VRWST,tRH,f - VRWST,tCS,i ftRH. f-tCS,i 405.8 sec
= <V1RH,t-1cs,i I ORwsr.tRH,t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.;
1,562.5 sec
= tRH,f + ~H,f-tCS,i At 633.8 sec
= tcs,; - teccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix I Ostr 3,899 gpm
= QRH I ntrain Veccs 32,655 ft3 Sht 12 of ATD-0111 Appendix I V1550 59,927 ft3 Sht 12 of A TD-0111 Appendix I Vcs 52,580 ft3
= V1560 - VRWST,tCSi '
Vavg 42,618 ft3
= <Veccs + Vcs) / 2 Vavg '
318,780 gal
= V_,
- 7.48 gallft3 nro 0.26
= QRH *At I (60 sec/min
- Vavg')
TOsATD-0111
Calculation 2014-04466 Revision 1 A
49 Calculation I Case 50 ECCS Switchover Initiation Time 51 RH Pumps Switched Over 52 RWST Volume Remaining at ~H.t RWST Outflow fort ;:: tRH.f Assuming RWST to RH 53 Pump Suction Isolation Valves Close 54 RWST Level at CS Switchover Initiation 55 RWST Feet per% Level 56 RWST Gallons oer Foot 57 RWST Volume at CS Switchover Initiation 58 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 59 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 60 Switchover Initiation 61 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 62 Switchover Initiation 63 RH Pump Flow 64 Number of Trains in Recirc 65 Flow per Strainer 66 Volume on Floor at fi=ccs 67 Volume on Floor at -1560 sec in ATD-0111 68 Approximate Volume on Floor at tcs.i 69 Average Volume on Floor 70 Average Volume on Floor 71 Number of Turnovers 72 Attachment A.2 Page A.2-7 of A.2-12 B
c D
E ATD-0111 Ar 11. J BRW 2 OSG fi=ccs 928.7 sec Sht 1 of ATD-0111 Appendix J
~H.f 1,156.7 sec Sht 1 of ATD-0111 Appendix J VRWST,IRH,f 114,151 gal Sht 1 of ATD-0111 Appendix J QRWST,IRH,f 8,752 gpm
= Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, P. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GoF 8,351.6 1aal/ft SITH-1, P. 14 VRwsr.tes.i 54,953.2 gal
= L0-3
- FpP
- GpF VRwsr.tes.i I
7,346.7 ft3
= VRwsrtcs.i I 7.48 gal/ft3 VtRH.f-tCS,i 59,197.8 gal
= VRwsr.tRH,t - VRwsr.tcs.i
!tRH,f-tCS,i 405.8 sec
= CVtRH.t-tcs.i I ORwsr.tRH.r)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.i 1,562.5 sec
= tRH,f + tRH.f-tCS,i i1t 633.8 sec
= tcs.i - tEccs QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close ntrain 2
Sht 1 of ATD-0111 Appendix J Ostr 3,899 gpm
= QRH I ntrain VEccs 32,144 ft3 Sht 12 of ATD-0111 Appendix J V156o 59,188 ft3 Sht 12 of ATD-0111 Appendix J Vcs 51,841 ft3
= V15so - VRwsr.1csi 1
Vavg 41,993 ft3
= <VEccs + Vcs) / 2 Vavg 1
314,105 gal
= Vava
- 7.48 gal/ft3 nro 0.26
= QRH
- i1t I (60 sec/min
- V avg')
TOs ATD-0111
Calculation 2014-04466 Revision 1 A
13 Calculation I Case 74 ECCS Switchover Initiation Time 75 RH Pumps Switched Over 76 RWST Volume Remaining at ~H.t RWST Outflow fort ~ ~H.t Assuming RWST to RH 77 Pump Suction Isolation Valves Close 78 RWST Level at CS Switchover Initiation 79 RWST Feet oer % Level 80 RWST Gallons nAr Foot 81 RWST Volume at CS Switchover Initiation 82 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 83 Comoletion and CS Switchover Initiation nme between RH Switchover Completion and CS 84 Switchover Initiation 85 nme at CS Switchover Initiation Time between RH Switchover Initiation and CS 86 Switchover Initiation 87 RH Pump Flow 88 Number of Trains in Recirc 89 Flow per Strainer 90 Volume on Floor at feces 91 Volume on Floor at -1560 sec in ATD-0111 92 Approximate Volume on Floor at tcs.1 93 Average Volume on Floor 94 Average Volume on Floor 95 Number of Turnovers Attachment A.2 Page A.2-8 of A.2-12 B
c D
E ATD-0111 Ac :i. K. BYR 2 OSG feces 928.7 sec Sht 1 of ATD-0111 Appendix K
~H.f 1,156.7 sec Sht 1 of ATD-0111 Appendix K VRwsT.tRH.t 114,151 gal Sht 1 of A TD-0111 Appendix K QRWST.tRH,f 8,752 gpm
= Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FoP 0.54833 ft!Olo SITH-1 o. 11 GpF 8,351.6 IQallft SITH-1, p. 14 V RWST,ICS,I 54,953.2 gal
= L0-3
- FpP
- GpF v
= VRWSrtes i / 7.48 gallft3 V1RH,f-tCS,I 59,197.8 gal
= VRWST,IRH,f - VRWST,ICS.I
~RH,1-tCS,i 405.8 sec
= (VtRH,f..tCS,i I ORwsr.tRH.t)
- 60 sec/min ; since this is less than 412 sec, CS switchover begins prior to SI switchover completion tcs.1 1,562.5 sec
=
~H.f + ~H,f-tCS,I 6t 633.8 sec
= tcs.i - tECCS QRH 7,797 gpm Total flow to 2 RH pumps modeled since RWST to RH pump suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix K Ostr 3,899 gpm
= QRH / 11tra1n VECCS 32,091 ft3 Sht 12 of A TD-0111 Appendix K V1560 59,185 ft3 Sht 12 of A TD-0111 Appendix K Vcs 51,838 ft3
= V1sso - VRWSr.tes1 I
Vavg 41,965 ft3
= <VEccs + Vcs) / 2 Vavg' 313,896 gal
= V~
- 7.48 gal/ft3 nro 0.26
= QRH
- 6t I (60 sec/min
- V avg')
TOsATD-0111
Calculation 2014-04466 Revision 1 I
A 1 Calculation I Case 2 ECCS Switchover Initiation Time 3 RH Pumps Switched Over 4 RWST Volume Remaining at tRH.f RWST Outflow fort ::: tRH,t Assuming RWST to RH 5 Pump Suction Isolation Valves Close 6 RWST Level at CS Switchover Initiation RWST Feet per% Level 7
RWST Gallons per Foot 8
RWST Volume at CS Switchover Initiation 9
RWST Volume at CS Switchover Initiation 10 RWST Volume Injected between RH Switchover 11 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 12 Switchover Initiation Time at CS Switchover Initiation 13 Time between RH Switchover Initiation and CS 14 Switchover Initiation RH Pump Flow 15 16 Number of Trains in Recirc 17 Flow per Strainer 18 Volume on Floor at ~ccs 19 Volume on Floor at -1560 sec in ATD-0111 20 Approximate Volume on Floor at ics,;
21 Average Volume on Floor 22 Average Volume on Floor 23 Number of Turnovers 24 Attachment A.2 Page A.2-9 of A.2-12 B
c D
E A TD-0111. AD il. H BRW 1 RSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix H tRH.f 1156.7 sec Sht 1 of ATD-0111 Appendix H VRWST,IRH.f 114151 gal Sht 1 of ATD-0111 Appendix H QRWST,tRH.f gpm = Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP ft!Olo SITH-1, p. 11 0.54833 GpF gal/ft SITH-1, p. 14 8351.6 VRWST,tCS,i gal
= L0-3
- FpP
- GpF
=C6*C7*C8 v
ft3
= VRwsT.tes,i / 7.48 gal/ft3 RWST,tCS,i
=C9/7.48 VtRH,f-tCS,i gal
= VR\\/VST,tRH,f - VRWST,tCS,i
=C4-C9
~H,f-tCS,i sec
= (VtRH,t-1cs,; I ORwsT,tRH,t)
- 60 sec/min; since this is less than 412
=C11/C5*60 sec, CS switchover begins prior to SI switchover completion tcs,;
sec
= ~H,f + tRH,f-tCS,i
=C3+C12 8t sec
= tcs,i - tECCS
=C13-C2 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix H Os1r
=C15/C16 gpm = QRH I n1ra;n VECCS 32589 ft3 Sht 12 of ATD-0111 Appendix H V1seo 59798 ft3 Sht 12 of A TD-0111 Appendix H Vcs
=C19-C10 ft3
= V1550 - VRWST,tesi Vavg
=(C18+C20)12 ft3
= (VEccs + Vcs) I 2 Vavg'
=C21*7.48 gal
= V avn
- 7.48 gal/ft3 n10
=C 15*C 14/60/C22
= QRH
- 8t I (60 sec/min* Vav9')
TOsATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
25 Calculation I Case 26 ECCS Switchover Initiation Time 27 RH Pumps Switched Over 28 RWST Volume Remaining at tRH,f RWST Outflow fort 2: tRH,f Assuming RWST to RH 29 Pump Suction Isolation Valves Close 30 RWST Level at CS Switchover Initiation 31 RWST Feet per % Level 32 RWST Gallons per Foot 33 RWST Volume at CS Switchover Initiation 34 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 35 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 36 Switchover Initiation 37 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 38 Switchover Initiation RH Pump Flow 39 40 Number of Trains in Recirc 41 Flow per Strainer 42 Volume on Floor at ~ccs 43 Volume on Floor at -1560 sec in ATD-0111 44 Approximate Volume on Floor at fcs,;
45 Average Volume on Floor 46 Average Volume on Floor 47 Number of Turnovers 48 Attachment A.2 Page A.2-10 of A.2-12 B
c D
E ATD-0111. Aa rl. I BYR 1 RSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix I tRH,f 1156.7 sec Sht 1 of ATD-0111 Appendix I VRwsT,tRH,f 114151 gal Sht 1 of ATD-0111 Appendix I QRWST,tRH,f gpm = Ocs + Ocv + 0 81 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 V RWST,tCS,i
=C30*C31*C32 gal
= L0-3
- FpP
- GpF v
I RWST,tCS,i
=C33/7.48 ft3
= VR'""'TtCS; / 7.48 gallft3 VtRH,f-tCS,i gal
= VRwsT,tRHJ - VRWST,tcs,;
=C28-C33 ttRH,1-tCS,i sec
= (VtRH,t-tcs,; I ORwsT,tRH,1)
- 60 sec/min; since this is less than 412
=C35/C29*60 sec, CS switchover begins prior to SI switchover completion ics,;
=C27+C36 sec
= tRH,f + tRH,f-tCS,i
~t sec
= ics,; - tECCS
=C37-C26 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close rltrain 2
Sht 1 of ATD-0111 Appendix I Os tr
=C39/C40 gpm = QRH I rltrain VEccs 32655 ft3 Sht 12 of ATD-0111 Appendix I V1550 59927 ft3 Sht 12 of ATD-0111 Appendix I Vcs
=C43-C34 ft3
= V1550 - VRwsT.tcs; I
Vavg
=(C42+C44)/2 ft3
= (VEccs + Vcs) I 2 Vavg I
=C45*7.48 gal
= Vavo
- 7.48 gallft3 nTo
=C39*C38/60/C46
= QRH * ~t I (60 sec/min* Vav9')
TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
49 Calculation I Case 50 EGGS Switchover Initiation Time 51 RH Pumps Switched Over 52 RWST Volume Remaining at tRH,t RWST Outflow fort <! tRH.f Assuming RWST to RH 53 Pump Suction Isolation Valves Close 54 RWST Level at CS Switchover Initiation 55 RWST Feet per % Level 56 RWST Gallons per Foot 57 RWST Volume at CS Switchover Initiation 58 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 59 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 60 Switchover Initiation 61 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 62 Switchover Initiation RH Pump Flow 63 64 Number of Trains in Recirc 65 Flow per Strainer 66 Volume on Floor at ~ccs 67 Volume on Floor at -1560 sec in ATD-0111 68 Approximate Volume on Floor at tcs.;
69 Average Volume on Floor 70 Average Volume on Floor Number of Turnovers 71 72 Attachment A.2 Page A.2-11 of A.2-12 B
c D
E ATD-0111 A111. J BRW 2 OSG tEccs 928.7 sec Sht 1 of ATD-0111 Appendix J
~H,f 1156.7 sec Sht 1 of ATD-0111 Appendix J VRWST,tRH,f 114151 gal Sht 1 of A TD-0111 Appendix J QRWST,tRH,f gpm = Ocs + Ocv + Q81 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 VRWST,tCS,i
=C54 *C55*C56 gal
= L0-3
- FpP
- GpF V RWST,tCS,i I
=C57/7.48 ft3
= VRwsr.tes.i / 7.48 gal/ft3 V tRH,f-tCS,i gal
= VRWST,tRH,f - VRWST,tCS,i
=C52-C57 ttRH,f-tCS,i sec
= (VtRH.t-tes,; I ORwsT,tRH,t)
- 60 sec/min ; since this is less than 412
=C59/C53*60 sec, CS switchover begins prior to SI switchover completion tcs,;
=C51+C60 sec
= ~H,f + tRH,f-tCS,i 6t sec
= fcs,; - tECCS
=C61-C50 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close lltrain 2
Sht 1 of ATD-0111 Appendix J Ostr
=C63/C64 gpm = QRH I lltrain VECCS 32144 ft3 Sht 12 of A TD-0111 Appendix J V15e0 59188 ft3 Sht 12 of ATD-0111 Appendix J Vcs
=C67-C58 ft3
= V15e0 - VRWST,tCSi '
Vavg
=(C66+C68)/2 ft3
= (VEccs + Vcs) / 2 Vavg '
=C69*7.48 gal
= Vava
- 7.48 gallft3 nro
= QRH
- 6t I (60 sec/min* Vav9')
=C63*C62/60/C70 TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 1 A
73 Calculation I Case 74 ECCS Switchover Initiation Time 75 RH Pumps Switched Over 76 RWST Volume Remaining at tRH.f RWST Outflow fort ;:: tRH,t Assuming RWST to RH 77 Pump Suction Isolation Valves Close 78 RWST Level at CS Switchover Initiation 79 RWST Feet per % Level 80 RWST Gallons per Foot 81 RWST Volume at CS Switchover Initiation 82 RWST Volume at CS Switchover Initiation RWST Volume Injected between RH Switchover 83 Completion and CS Switchover Initiation Time between RH Switchover Completion and CS 84 Switchover Initiation 85 Time at CS Switchover Initiation Time between RH Switchover Initiation and CS 86 Switchover Initiation RH Pump Flow 87 88 Number of Trains in Recirc 89 Flow per Strainer 90 Volume on Floor at ~ccs 91 Volume on Floor at -1560 sec in ATD-0111 92 Approximate Volume on Floor at tcs.i 93 Average Volume on Floor 94 Average Volume on Floor 95 Number of Turnovers Attachment A.2 Page A.2-12 of A.2-12 B
c D
E ATD-0111 All o. K BYR 2 OSG tECCS 928.7 sec Sht 1 of ATD-0111 Appendix K tRH.f 1156.7 sec Sht 1 of ATD-0111 Appendix K VRWST,tRH.f 114151 gal Sht 1 of ATD-0111 Appendix K QRWST,tRH,f gpm = Ocs + Ocv + 0 51 ; Backflow and RH pump flow from RWST do
=7085+831+836 not occur if valves operate correctly.
L0-3 12 SITH-1, p. 20 FpP 0.54833 ft/%
SITH-1, p. 11 GpF 8351.6 gal/ft SITH-1, p. 14 VRWST,tCS,i
=C78*C79*C80 gal
= L0-3
- FpP
- GpF v
RWST,tCS,i
=C81/7.48 ft3
= V Rwsr 1cs i I 7. 48 gallft3 V tRH.f-tCS,i gal
= VRwsT.tRH.t - VRwsT.tCS,i
=C76-C81 ttRH.f-tCS,i sec
= (VtRH.t-tes.i I ORwsT,tRH,t)
- 60 sec/min; since this is less than 412
=C83/C77*60 sec, CS switchover begins prior to SI switchover completion tcs,i
=C75+C84 sec
= ~H.f + tRH,f-tCS,i 8t sec
= ics.; - tEccs
=C85-C74 QRH gpm Total flow to 2 RH pumps modeled since RWST to RH pump 7797 suction valves are assumed to close r\\rain 2
Sht 1 of ATD-0111 Appendix K Ostr
=C87/C88 gpm = QRH I Otrain VEccs 32091 ft3 Sht 12 of ATD-0111 Appendix K V1560 59185 ft3 Sht 12 of A TD-0111 Appendix K Vcs
=C91-C82 ft3
= V1560 - VRWST,teSi' Vavg
=(C90+C92)/2 ft3
= (VEccs + Vcs) I 2 Vavg'
=C93*7.48 gal
= Vavn
- 7.48 gal/ft3 nro
=C87*C86/60/C94
= QRH
- 8t I (60 sec/min* Vav9')
TOs ATD-0111 (Eqs)
Calculation 2014-04466 Revision 0 Attachment B ATTACHMENT B: AVAILABLE DRIVING HEAD 1.0 Purpose Page Bl ofB3 Per Limitation 1 in Section 4.0 of the Safety Evaluation to WCAP-16793 [Ref. 2.1]
"Licensees should confirm that their plants are covered by the PWROG sponsored fuel assembly tests by confirming that the plant available hot-leg break driving head is equal to or greater than that determined as limiting in the proprietary fuel assembly tests." Therefore, the purpose of this attachment is to calculate the hot-leg break available driving head and compare it to the proprietary fuel assembly tests.
2.0 Design Input 2.1 Hot-Leg Centerline Elevation Per Drawing M-196 [Ref. 2.3] the hot-leg centerline is at an elevation of393 feet for Byron Units 1 and 2 and Braidwood Units 1 & 2.
2.2 Elevation of the Bottom of the Core Per Drawing 113E977 [Ref. 2.2] for Byron Units 1 & 2 and Braidwood Units 1 & 2 the bottom of the active core is 206.625 inches (62.625"+144")
below the center of the hot-leg (393 feet, Design Input 2.1 ). Therefore, the elevation of the bottom of the active core is 375.78 feet (393 - 206.625/12).
2.3 Elevation of Bottom of the Hot-Leg The hot-leg centerline is at an elevation of 393 feet (Design Input 2.1 ). The hot-leg piping has an inner diameter of 29 inches [Table 5.4-5 of Ref. 2.9].
Therefore, the elevation of the bottom of the hot-leg is equal to the hot-leg centerline elevation minus half the inner diameter of the hot-leg which is equal to 391.79 feet (393-29/12/2).
2.4 Steam Generator Tube Spillover Elevation The minimum steam generator tube spillover elevation for Byron and Braidwood Unit 1 is 431.8 feet [Ref. 2.10.10]. The minimum steam generator tube spillover elevation for Byron and Braidwood Unit 2 is determined by adding the elevation of the top of the steam generator pedestals [396.5 feet, Refs. 2.10.1-2.10.8] to the distance from the steam generator pedestal to the spillover elevation of the lowest tube [greater than 28.5 feet, Ref. 2.10.9]. This results in a steam generator tube spillover elevation of 425 feet for Byron and Braidwood Unit 2. Very minor differences in dimensions were noted across all of the steam generators across each station; however, the numbers used were selected to bias the steam generator tube spillover elevation lower which is conservative. For
Calculation 2014-04466 Revision 0 Attachment B Page B2 ofB3 conservatism the lowest steam generator tube spillover elevation is used for all units.
2.5 Maximum Core Temperature Analyzed The maximum core temperature does not have a significant impact on the available driving head; therefore, a bounding temperature of 300°F is used for this analysis. The saturation pressure at a temperature of 300°F is 67 psia which bounds the computed post-LOCA containment pressures in CN-CRA-10-54 [Ref. 2.4].
2.6 Minimum Core Temperature Analyzed A minimum Post-LOCA sump temperature of 120°F is used which is consistent with WCAP-17057-P [Section 6.7.1 of Ref. 2.6]. The use of a lower sump temperature (i.e. 60°F) would not change the conclusions of this analysis.
3.0 Methodology The hot-leg break available driving head is calculated using the methodology in Section 10.3.2.3 of Attachment 1 to LTR-SEE-1-10-23, Rev. 1, which is included as Attachment K to WCAP-16793-NP, Rev. 2 [Ref. 2.7]. The methodology is provided in response to RAJ # 18 in the PWROG Response to Request for Additional Information Regarding Topical Report WCAP-16793-NP [Ref. 2.8].
According to the SE to WCAP-16793, "if licensees maintain the 15 gram debris limit established for hot-leg breaks, the cold-leg break may be bounded by the hot-leg break," [page 15 of Ref. 2.1]. Therefore, because Byron/Braidwood meets the 15 gram per fuel assembly debris limit (see Attachment A) the cold-leg break driving head is not calculated herein.
The available hot-leg break driving head equals the elevation head in the downcomer and steam generator tubes up to the spillover elevation minus the elevation head in the core.
Where:
dP. = (zso - Zcore-tn )Pnc (zbrk - Zcore-1n )Pcore avml 144 144 dP avail = Available driving head (psi)
Zso =Steam Generator tube spillover elevation (ft)
Zcore-in Elevation of the bottom of the core (ft)
Zbrk Elevation of the bottom of the hot-leg (ft) poc = density in downcomer and steam generator (lbm/ft3)
Peare= density in core (lbm/ft3)
Calculation 2014-04466 Revision 0 Attachment B Page B3 ofB3 Since it is expected that the lowest density, hottest water would be in the core, it is conservatively assumed that the density in the core is equal to the density in the downcomer and steam generator tubes (i.e. Pnc = Peare).
The post-LOCA water temperature in the core can range from 120°F (Design Input 2.6) to 300°F (Design Input 2.5). The density of water at the minimum and maximum analyzed temperatures is 61.7 1bm/ft3 and 57.3 1bm/ft3, respectively [Ref.
2.5].
4.0 Results The available hot-leg break driving head therefore ranges from 13.2 to 14.2 psi.
dP. = (425-375.45 )* 57.3 _ (391.79-375.45 )* 57.3= 13.2 sid at 300oF avail 144 144 p
dP. = (425-375.45)* 61. 7 _ (391.79-375.45)* 61. 7 = 142 sid at 120oF avail 144 144 p
The above calculation is conservative since the core density is less than the downcomer density.
5.0 Conclusions Regarding Available Driving Head According to WCAP-17057-P [Bullet 1 on page 6-51 of Ref. 2.6], the testing with 15 grams of fiber per fuel assembly resulted in a maximum debris head loss of 2. 7 psi. Therefore, Byron/Braidwood, which has less than 15 grams of fiber per fuel assembly (see Attachment A) will have an available driving head that is greater than the debris head loss.
In addition, Section 10.2 of Reference 2. 7 states the following: "The AREVA testing conducted in support of this program demonstrated that 15 g of fiber/FA does not cause a blockage that will challenge LTCC, the maximum pressure drop due to debris ( dP debris) was very small and all plants have an available driving head (dPavaiI) that is considerably greater. Therefore, all PWROG plants can demonstrate LTCC is not impeded ifthe plant-specific fibrous debris load is less than or equal to 15 g of fiber/FA."
Calculation 2014-04466 Revision 0 Attachment C Page Cl of Cl ATTACHMENT C: MAXIMUM FLOW RATE PER FUEL ASSEMBLY The maximum cold-leg recirculation flow is 4,212 gpm per Section 8.3 and Table 6.2 of Calculation No. BYR06-029 I BRW-06-0016-M [Ref. 2.11]. Based on 2 train operation the maximum flow rate would be 8,424 gpm (=4,212*2). The maximum flow rate per fuel assembly is calculated to be 43.6 gpm I fuel assembly and is found by dividing the maximum cold-leg recirculation flow (8,424 gpm) by the number of fuel assemblies [193 fuel assemblies, Ref. 2.9].
Note, the hot-leg recirculation flow rate in Calculation No. BYR06-029 I BRW-06-0016-M
[Ref. 2.11] is slightly higher than the cold-leg recirculation flow rate. However, per page 64 of the SE for WCAP-16793-NP, Rev. 2, the potential for core blockage during hot-leg recirculation is bounded by cold-leg recirculation; therefore, using the maximum flow rate during cold-leg recirculation is appropriate. Also, the cold-leg recirculation flow is based on non-erosion cases since the erosion cases are representative of times further into the LOCA transient beyond hot leg switchover.
Calculation 2014-04466 Revision O Exelon Powerlabs, LLC.
Technical Services West 36400 S. Essex Road Wilmington, IL 60481-9500 www.exelonpowerlabs.com 815-458-7640 815-458-7851 fax To:
From:
Project Number:
Subject:
B. Davenport Mechanical/Structural Engineering Cantera William Treasurer (815)458-7654 william. treasurer@ExelonCorp.com EXE-82632 Sump Strainer Particle Loading Page 01 of 028 Exelon Powerlabs Water samples taken during Tests 3 and 6 of Control Components Inc.
(CCI) Large-Scale Performance Testing of Containment Sump Strainers November, 2005
Reference:
CCI specification Q.003.84748, Rev. 2, dated 11/10/05.
Date:
02/0l/2006DRAFf Exelon is involved with purchasing new strainers for the containment sumps at the Exelon PWRs.
This is being driven by an NRC Generic Safety Issue (GSI) 191, which involves post-LOCA debris blockage of the containment sump screens. For Byron & Braidwood the strainer manufacturer is Control Components Inc. (CCI).
Part of the testing of the replacement strainers involves determining the amount of fibrous &
particulate debris which can get through the sump strainer as these contaminants can impact analysis for components downstream of the strainer (e.g. reactor fuel). This has been referred to as "strainer bypass" or efficiency. During CCI large scale strainer testing, provisions were made to take water samples of the downstream flow to assist in determining the strainer bypass efficiency for various debris constituents.
Water samples of the flow stream were shipped to the Exelon Power Labs at Wilmington, IL for assistance with determining the amount of fibers and particulate debris contained in samples of the water downstream of the new strainer. The samples were taken during performance of Tests 3 and 6 The Exelon Powerlabs Quality System meets 10CFR50 Appendix B, 10CFR21, ANSI N45.2, ANSl/NCSL Z540-1, and NQA-1.
Calculation 2014-04466 Revision O Page 02 of 028 of the referenced CCI large-scale performance tests in November 2005. CCI also took downstream samples concurrently during all of the test cases. The results of this Exelon determination of fiber and particulate bypass will be used for further analysis input and as a comparison to the CCI test data.
- 1. The mg/L solids data found in Tables 1 & 2 were reported on December 2, 2005.
- 2. None of the material in all the Test 3 water samples was classified as large (greater than 0.083 inches).
- 3. Most of the particulates present in Tests 3 and 6 were non-fibrous based upon visual examination of the filters.
- 4. The fiber mass calculated from the estimated total fiber volume of the selected Test 6 samples indicated that most of the solids reported in Table 1 are due to non-fibrous material.
- 1. Measure the mass per volume of material on the water samples submitted. There are two sets; a fiber only set (Test# 6) and a fiber plus particulate set (Test# 3). Provide preliminary results on the first twenty samples from each set by December 8th (depending on the sample receipt date). Provide preliminary results on the first twenty samples within 1 week after receipt. The balance of the results within 2 weeks.
- 2. Measure the fiber dimensions from selected Test 6 filter samples, so that an estimate of the mass of the fibers can be calculated.
- 3. Take representative photographs from the feed stock material used for Test 3, all Test 3 Filters, and selected Test 6 Filters.
TEST PLAN ON MEASURING THE AMOUNT OF DEBRIS IN STRAINER WATER SAMPLES I.
Scope: Measure the mass per volume of debris in the downstream water samples passing through the strainer.
- 1.
Rinse all glassware with DI water before proceeding with each filtration.
- 2.
Shake each bottle vigorously just before filtering to suspend all fiber and debris that may have settled.
- 3.
Using a matched weight Millipore 0.8-micron filter, assemble the filtering apparatus.
- 4.
Filter an appropriate volume of water. Record the sample bottle's weight before transferring to the filter apparatus and after filtering. The difference of the sample bottle weighings is the volume of water filtered. For very lightly loaded water, this volume might be the complete 500 ml sample.
- 5.
If the entire bottle contents are used, rinse the bottle with DI water and add that to the filtering apparatus to be filtered.
- 6.
Rinse the filter assembly with DI water.
Project Number: EXE-82632 Page 2 of 28
Calculation 2014-04466 Revision O Page 03 of 028
- 7.
Carefully removed each of the matched weight filters and transfer each set to glass Petri dishes.
- 8.
Dry in an oven at 95 C (+/-3 C) for 30 minutes (ref: ASTM D2276).
- 9.
Allow the filters to cool in a desiccator.
- 10.
Weight both the blank filter and the sample filter on an analytical balance to 0.0001 g.
- 11.
Calculate the PPM (mg/l) as follows:
PPM (MG/L) =(W2-Wl)N Where W2 =Sample Weighting Wl= Blank Weighting V= Volume Used in mL (assumes density of water= 1.00 g/mL)
II.
Scope: Estimate the Relative Size of the Fibers on the filters from the Fiber Set (Test# 6).
Note that this will be a visual volume estimate under a stereoscope. The longest dimension of the fiber (bundle) will be used. Use this data to calculate the mass of fiber present.
- 1.
Verify the reticule markings with a secondary standard of known dimensions at various magnifications.
- 2.
Photograph typical fields as necessary.
- 3.
The particulate population consists of fiberglass, and possibly "stone flour, typically greater than 60 microns" particulate and "zinc powder, approximately 30 to 40 micron" particulate, and glass.
- 4.
On selected samples (based on discussions with Mr. Davenport) perform length measurements of the fiberglass on the filter membrane. Verify the fiberglass fibers' diameter.
- 5.
Under a stereoscope, examine fields of view and classify the fiberglass fiber dimensions.
Measure the length of the fibers. For the purpose of this study particles are classified as follows:
Large: >/= 0.083 inches+ 10 %
(0.0913 "= 2320 microns, 0.083" = 2110 microns)
Small: < 0.083 inches.
Note: Because of the magnifications used, particulate/fibers under approximately 20 microns are excluded.
- 6.
After the total sum the numbers of fiberglass fibers and their lengths are known, their mass can be calculated using the fiberglass's density of 159-lbs/cubic foot, the measured lengths, and the measured diameters.
- 7.
Enter the data from the fiber counting I sizing in an Excel spreadsheet for final calculations.
Project Number: EXE-82632 Page 3of28
Calculation 2014-04466 Revision 0 AMOUNT OF DEBRIS IN STRAINER WATER SAMPLES Page 04 of 028 Tables 1 & 2 summarize the gravimetric determination of the total mass in the submitted water samples. The total volume of the submitted water samples (ranged from 450 to 480 mL) was used for these measurements to maximize the test's sensitivity. It should be noted that the number of filter sets per sample varied from 1 to 8 depending on the particulate density. All the Test 6 samples and Nos. 13-30 Test 3 samples were weighed on single sets of filters. Test 3 Nos. 7-12 was weighed on 2 filter sets, Nos. 5 & 6 used 3, No. 4 used 4, No. 3 used 5, No. 2 used 7 and Test 3 No. 1 used 8 filter sets. This sub sampling was performed to provide an opportunity for subsequent visual particle counting.
Time Number 16:30:00 1
16:32:30 2
16:35:00 3
16:37:30 4
16:40:00 5
16:42:30 6
16:45:00 7
16:47:30 8
16:50:00 9
16:52:30 10 16:55:00 11 16:57:30 12 17:00:00 13 17:02:30 14 17:05:00 15 Table 1 Test 6, November 15, 2005 Solids Time mWL 9
17:07:30 37 17:10:00 12 17:12:30 36 17:15:00 6
17:17:30 13 17:20:00 7
17:22:30 6
17:25:00 4
17:27:30 5
17:30:00 4
17:32:30 2
17:35:00 2
17:37:30
<1 17:40:00 1
17:42:30 Number Solids mg/L 16
<1 17 2
18 3
19 4
20 4
21 4
22 6
23 4
24 4
25 5
26 5
27 5
28 4
29 5
30 5
Project Number: EXE-82632 Page 4 of 28
Calculation 2014-04466 Revision O Time 8:45:00 8:50:00 8:55:00 9:00:00 9:05:00 NA 9:15:00 9:20:00 9:25:00 9:30:00 9:35:00 9:40:00 9:45:00 9:50:00 9:55:00 Number 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 Table 2 Test 3, November 17, 2005 Solids Time mWL 852 10:00:00 356 10:05:00 262 10:10:00 137 10:15:00 84 10:20:00 65 10:25:00 53 10:30:00 39 10:35:00 28 10:40:00 21 10:45:00 19 10:50:00 23 10:55:00 17 11:00:00 14 11:05:00 12 11:10:00 Page 05 of 028 Number Solids m~/L 16 10 17 7
18 5
19 6
20 4
21 5
22 2
23 3
24 2
25 1
26 1
27 3
28 4
29 1
30
<1 CALCULATION OF MASS OF FIBERGLASS FIBERS IN TEST 6 SAMPLES Based on the reported values in Table 1, it was agreed to calculate the mass of fiberglass fibers in Samples 1, 2, 3, 5, 8, 11 and 14 from Test 6.
Determination of Fiberglass Fiber Diameter Fifteen random fibers were measured (from filters 6-8, 6-11, & 6-14) on the scanning electron microscope (SEM) for their diameters. The diameters ranged from 4.99 to 13.l microns, with an average diameter of 8.45 microns. There were also some fibers coated with a zinc crystalline compound. This phenomenon was only on the fibers from the actual test samples. The sample of fiberglass used in Tests 3 and 6 did not have the zinc coating.
The following are samples of photographs taken on the SEM of various fibers (see Photographs 1-5 and Spectrum 1 & 2). The average diameter of 8.45 microns and maximum diameter of 13.1 were both used to calculate the estimated mass of fiberglass present.
Project Number: EXE-82632 Page 5of28
Calculation 2014-04466 Revision O Attachment O Counting and Measuring Fiberglass Fibers Page 06 of 028 The counting and measuring of the fiberglass fibers was performed with a stereomicroscope at 11 OX.
One hundred percent of the fibers were counted for all the selected Set 6 samples except for Sample
- 1. For Sample 1 the uniform fiber distribution and density permitted that random fields of views could be used. The fibers were long rods, varying from straight to curved. Individual fibers lengths were measured. Many fibers bundled (typically bundles of 2 to 5 fibers). In these cases an effort was made to measure each fiber of the bundle. When the fibers were curved the lengths were a best estimate.
It should be noted that there were many more non-fibrous particles than the fiberglass.
Photograph 6 is of a graticle at the 11 OX magnification. Each division is 10 microns longs. The fibers counted ranged from 100 to greater than 21,000 microns in length, but were generally in the 100 to 1000 micron range.
Calculation of the Estimated Mass of Fiberglass Fibers in Test 6 Samples Table 3 summarizes the calculated mg/L density based on the provided fiberglass density (159 # I ft3), the measured fiber lengths, and the average fiber diameter or the maximum fiber diameter. Test 6 was performed on 11/15/2005.
In performing this type of testing various errors are possible. There is an uncertainty due to the variability of the fiberglass fiber's diameter. Because of this the mass calculation based on the mean and maximum fiber diameter was provided. There are also inaccuracies in determining fiber lengths due to the non-linear nature of many of the fibers, and miss-counting fibers due to that are hidden under other solids. There is a potential of missing or double counting fibers as the filter surface is scanned.
Table 3-Calculated Mass from Estimated Fiber Volume Measurements Test# 6 (11-15-05) 6-1 6-2 6-3 6-5 6-8 6-11 6-14 Time 1630 1632:30 1635 1640 1647:30 1655 1702:30
- of Fibers Counted 98*
1158 261 233 88 93 35 mg/L Fiberglass, 1.0 0.71 0.14 0.13 0.06 0.06 0.01 using average diameter mg/L Fiberglass, 2.5 1.7 0.34 0.31 0.14 0.13 0.05 using maximum diameter Total Suspended Solids 9
37 12 6
6 4
<1 from gravimetric (9.1)
(36.7)
(11.6)
(5.8)
(5.5)
(3.6)
(0.4) measurements, mg/L
- Because of uniform distribution and high fiber density, only ten areas of view (approximately one thirtieth of the total filter area) were counted. The factor of 29.7 was then used to calculate the fiber concentration.
Project Number: EXE-82632 Page 6 of 28
Calculation 2014-04466 Revision O Page 07 of 028 PHOTOGRAPHS OF FEED STOCK MATERIAL and FILTERS Fields of view of selected Test 6 and all Test 3 filters were taken.
Photographs 7 to 22 are of the Test 6 samples that were counted in Table 3. All Photographs were taken at 11 OX. What should be noted in these pictures is that with the exception of Sample 6-1, there are many more non-fibrous particles present than the fiberglass fibers.
Photographs 23 to 26 were taken at 1 lOX of the feedstock that was used for Test 3. The feedstock was fiberglass, pieces of glass, zinc powder (IOZ) and stone flour.
Photographs 27 through 89 were taken to document the material collected on the filters for Test 3.
There are photographs at both 18 and 110 X of each filter.
Data was provided to Mr. Davenport as it became available.
Testing was performed with standards and/or equipment that have accuracies traceable to nationally recognized standards or to physical constants, by qualified personnel, and in accordance with the Exelon PowerLabs Quality Assurance Program revision 17 dated 08/30/2005.
Technician(s): W. Treasurer Prepared by:
(signed original in file)
Approved by:
(signed original in file)
Title xx/xx/2005 cc:
J. Panici, Mod Design, Braidwood K. Dhaese, Mod Design, Byron.
I. Garza, Sargent Lundy B. Davenport, Mechanical/Structural Engineering, Cantera Project Number: EXE-82632 Page 7 of 28
Calculation 2014-04466 Revision O
- 1 i
u
- .OJO Page 08 of 028 Fiber Diameter Characterization Photograph 1 Fiberglass Feedstock used in Test 6.
The diameters varied from 5 to almost 10 microns. No zinc deposition was seen. The length to width ratio was in excess of 10:1.
Spectrum 1 Typical EDXA spectrum of fiberglass; it is primarily silicon with lesser amounts of sodium, calcium, oxygen, aluminum, magnesium and potassium. There is a small gold peak because the fibers were gold-coated as part of the SEM re aration.
Photograph 2 Some fibers from 6-11 Project Number: EXE-82632 Page 8 of28
Calculation 2014-04466 Revision o Attachment O Page 09 of 028 Photograph 3 More fibers from 6-11, note that they are joined (bundled) along the axis Photograph 4 Close-up of a fiber that has been coated with a zinc compound from 6-11 Project Number: EXE-82632 Page 9of28
Calculation 2014-04466 Revision O u*n Z11
- .o:io XJlt4lP,~ 1:1-?*.>
zn Ca Attachment O Page 010 of 028 10.:i90 Photograph 5 Coated fiber showing fiberglass core and zinc coating Spectrum 2 EDXA of the zinc coating on the fiber Photograph 6 This is a photograph of a graticle scale at approximately 110 X.
Each division is 10 microns; the entire length is 1000 micron.
Project Number: EXE-82632 Page 10 of 28
Calculation 2014-04466 Revision 0 Attachment O Page 011 of 028 Photographs of the Filters at llOX Photograph 7 Filter 6-1, View 1 Photograph 8 Filter 6-1, View 2
, Photograph 9 Filter 6-1, View 3 Project Number: EXE-82632 Page 11of28
Calculation 2014-04466 Revision o Page 012 of 028 Photograph 10 6-2, View 1 Photograph 11 6-2, View 2 Photograph 12 6-2, View 3 Project Number: EXE-82632 Page 12 of 28
Calculation 2014-04466 Revision O Page 013 of 028 J Photograph 13 1 Filter 6-3, View 1 Photograph 14 Filter 6-3, View 2 Photograph 15 Filter 6-5, View 1 Project Number: EXE-82632 Page 13 of 28
Calculation 2014-04466 Revision O
- *. l""'",
.~
~
- . f:
Page 014 of 028
,,.- - e -.
.~
Photograph 16 Filter 6-5, View 2
,, Photograph 17 Filter 6-5, View 3
~ "*
Photograph 18
- Filter 6-8, View 1 Project Number: EXE-82632 Page 14 of 28
Calculation 2014-04466 Revision 0 Attachment O
._F *t# **~*
~.....
- l>
Page 015 of 028 Photograph 19 1 Filter 6-8, View 2 Photograph 20
' Filter 6-11, View 1 Photograph 21 Filter 6-11, View 2 Project Number: EXE-82632 Page 15 of 28
Calculation 2014-04466 Revision O Attachment O Photograph 22 Filter 6-14, View 1 Photographs of the Feed Stock Materials at llOX Page 016 of 028 The following are photographs of the materials used for Test 3 taken with the stereomicroscope at llOX.
Photograph 23 Fiberglass Project Number: EXE-82632 Page 16 of 28
Calculation 2014-04466 Revision 0 Attachment O Page 017 of 028 Photograph 24 Glass, Much of the glass used were larger fragments than this one.
Photograph 25 Zinc Powder, IOZ Photograph 26 Stone Flour Project Number: EXE-82632 Page 17 of 28
Calculation 2014-04466 Revision o Page 018 of 028 Photographs from Test 3 mm Scale, at 18X, each division is 1000 microns (1 mm) 3-2, at 18X Photo ra h 31 Graticle scale at approximately 110 X.
Each division is 10 microns; the entire length is 1000 micron.
3-2, at llOX Photo ra h 32 Project Number: EXE-82632 Page 18 of 28
Calculation 2014-04466 Revision O 3-5, at 18X Photo ra h 37 Page 019 of 028 3-5, at llOX Photo ra h 38 Project Number: EXE-82632 Page 19 of 28
Calculation 2014-04466 Revision O 3-7, at 18X Photo ra h 41 3-8, at 18X Photo ra h 43 Attachment O Page 020 of 028 3-7, at llOX 3-8, at llOX Photo ra h 44 Project Number: EXE-82632 Page 20 of 28
Calculation 2014-04466 Revision O
- 5T~ :~*:.r.~:=:~[*::~~ ~*F~:*.:~:**:.:
A,'..
Photo ra h47..
3-11, at 18X Photo ra h 49 Page 021 of 028 3-11, at llOX Photo ra h 50 Project Number: EXE-82632 Page 21 of 28
Calculation 2014-04466 Revision 0 3-14, at 18X Photo ra h 55 Attachment O Page 022 of 028 3-14, at llOX Photo ra h 56 Project Number: EXE-82632 Page 22 of 28
Calculation 2014-04466 Revision 0 3-17, at 18X Photo ra h 61 Page 023 of 028 3-17, at llOX Photo ra h 62 Project Number: EXE-82632 Page 23of28
Calculation 2014-04466 Revision O 3-20, at 18X Photo ra h 67 Page 024 of 028 3-20, at llOX Photo ra h 68 Project Number: EXE-82632 Page 24 of 28
Calculation 2014-04466 Revision 0 3-23, at 18X Photo ra h 73 Attachment O Page 025 of 028 3-23, at llOX Photo ra h 74 Project Number: EXE-82632 Page 25 of 28
Calculation 2014-04466 Revision 0 3-26, at 18X Photo ra h 79 Page 026 of 028 3-26, at llOX Photo ra h 80 Project Number: EXE-82632 Page 26of28
Calculation 2014-04466 Revision O 3-29, at 18X Photo ra h 85 Attachment O Page 027 of 028 3-29, at llOX Photo ra h 86 Project Number: EXE-82632 Page 27of28
Calculation 2014-04466 Revision O 3-30, at 18X Photo ra h 88 Page 028 of 028 3-30, at llOX Photo ra h 89 Project Number: EXE-82632 Page 28of28