Facility: Clinton Power Station IL T 14-1 NRC Scenario No.: _1_

Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 24%. Reactor startup is in progress.

Thunderstorms are expected in the area within the next hour.

Turbine Driven Reactor Feed Pump (TDRFP) 'B' is out of service for minor maintenance.

Restoration is expected prior to transferring RR Pumps 'A' and 'B' to fast speed.

Turnover:

Cross-tie 480V Buses 1 L & 1 M with 1 L supplying per CPS 3502.01 480 VAC Distribution.

Continue reactor startup. Raise reactor power to 29% in preparation for Reactor Recirculation (RR) pump shift to fast speed.

Even Malf. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Cross-tie Unit Sub 1 L & 1 M with 1 L supplying 2

¥P--X:Mi;m 50'1.t-.

+S SR9' L-Pes Roorn Fan trip-I~

3 YFFWPPSS_ 13 C-BOP/SRO MC Pump 1 B coupling failure 4

Ai1 _A05_S40_2 ON TS-SRO Loss of Control Power to Suppression Pool A11 _A02_07_4_TVM 2 Dump Valve 1 SM001 A A 11_A08_DS30_1 OFF 5

A11 _A02_03_7_TVM 2 C-BOP/SRO Low Flo~ CW Bearing Seal Water 6

N/A A-ATC/SRO Raise power with rods to 29%

7 ROD1641TFIA5 C-ATC/SRO Uncoupled Rod 8

Y AFWPPLB_ 15 C-ATC/SRO TDRFP 'A' High Bearing Temperature 9

YP _XMFTB_5082 M-PC-12 RPV Ref Leg Leak In Gas Control BOP/SRO/ATC Boundary 10 CAM1 PR006(NB/C/D)TV _

VALUE1 = 21-24 mr A11 _A03_01 _4_TVM 4 A 11_A03_02_3_ TVM 4 A 18_A03_S11 = 1 C-BOP/SRO Radiation Monitor fails to isolate VF/Startup VG A 18_A03_S10 = 1 A12_A01 _07 _6_TVM 2 A12_A02_07_6_TVM 2 (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 1 D-1 Rev 0 75 Day Submittal Page 1 of3

Scenario No.:

1 Operating Test No.: 2015-301 Narrative Summary Event#

Description

1.

Cross-tie Unit Sub 1 L & 1 M with 1 L supplying Following shift turnover, the SRO will direct the BOP Operator to cross-tie 480V Buses 1 L

& 1 M with 1 L supplying per CPS 3502.01 480 VAC Distribution section 8.1.4 Transferring a 480V Bus: Paralleling Method.

2.

LPCS Room Fan trip Annunciator 5050-1 C Not Available VY System Division 1 will be received. The BOP operator will determine that the LPCS Supply Fan 1 VY01 C has tripped. If the BOP attempts to restart the fan, the fan will fail to start. The crew will monitor LPCS Pump Room temperature and dispatch an Equipment Operator to determine the cause of the trip. The SRO will evaluate and enter ITS 3.5.1 ECCS - Operating Required Action A.1 Restore low pressure ECCS injection/spray subsystem to OPERABLE status within 7 days.

3.

MC Pump 1 B coupling failure Annunciator LOW PRESS MAKE-UP COND XFER PUMPS DISCH HOR (5014-2C) comes in due to the Make-Up Condensate Transfer Pump 1 B (OMC01 PB) shaft shear.

The BOP Operator will dispatch a field operator to investigate. Upon the report of a shaft shear, the BOP operator will stop the failed pump and start the standby pump per CPS 3208.01 Cycled/Makeup Condensate Section 8.1.1 (or 8.2.2).

4.

Loss of Control Power to Suppression Pool Dump Valve (SM001 A)

Annunciator NOT AVAILABLE SM SYSTEM DIVISION 1 (5041-70) comes in due to a blown control power fuse deenergizing relay 74-SM1A (1SM001A Bkr Overload relay).

The BOP operator will dispatch a field operator to investigate. Technical Specification LCO 3.6.2.4, Action C.1 will be evaluated requiring the restoration of the SPMU subsystem to operable status within 7 days.

5.

Low Flow CW Bearing Seal Water Annunciator 5041-3G LOW FLOW CW PUMP 1C BRG SEAL WATER comes in due to CW Pump 'C' seal water flow less than the setpoint (15 gpm). The BOP operator will dispatch an Equipment Operator to investigate. Seal water flow to Circulating Water (CW) Pump 1 C cannot be restored requiring the BOP operator to trip CW Pump 1 C and start CW Pump 1 A.

6.

Raise power with rods to 29%

The crew will raise Reactor power with Control Rods to achieve -29% Reactor Power IAW CPS 3004.01 TURBINE STARTUP AND GENERATOR SYNCHRONIZATION in preparation for transferring RR pumps to FAST speed.

7.

Uncoupled rod When the first in-sequence control rod reaches position 48, the ATC will perform a coupling check IAW CPS 3304.02 Rod Control And Information System (RC&IS) section 8.1.10 Coupling Check by applying a continuous withdraw to the rod at position 48.

Annunciator 5006-5G Rod Overtravel will be received, indicating that the control rod has become uncoupled from its drive mechanism. The operating crew will attempt to recouple the control rod IAW the annunciator response procedure. The SRO will evaluate and enter ITS 3.1.3 Condition C until the control rod is successfully recoupled.

8.

TDRFP 'A' High Bearing Temperature Annunciator 5002-2C HIGH TEMP RFPT 1 A BRG comes in due to a failed bearing in the

'A' RFPT. With the 'B' TDRFP tagged out, the crew will start the MDRFP and secure the

'A' TDRFP IAW CPS 3103.01 Feedwater (FW) section 8.3.6 High Temperature TDRFP Bearings.

9.

RPV Instrument Line leak Scenario 1 D-1 Rev 0 75 Day Submittal Page 2 of 3

An RPV instrument line will break resulting in a partial loss of RPV instrumentation, a steam leak in the secondary containment and EOP-8 entry. Two areas in secondary containment will exceed Maximum Safe temperature requiring blowdown. The crew may Anticipate Slowdown using bypass valves prior to two areas reaching max safe.

10. Radiation Monitor fails to isolate VF/Startup VG EOP 8, 1, 3 Due to the RPV instrument line leak in the secondary containment, the VF exhaust radiation monitors trend up to the trip isolation set point but fail to actuate VF system isolation and start of VG requiring BOP to manually perform.

Critical tasks:

SC-1.1 ATC inserts a manual Scram before area temperature reaches max safe in any one area.

SC-1.2 SRO enters EOP-3 and performs a blowdown when 2 or more areas are above the max safe value of the same parameter (Table T, U, W), and a Primary System is discharging into the Secondary Containment, which cannot be isolated. If the crew Anticipates Slowdown using bypass valves, and in doing so two areas do not reach a max safe condition, then this critical task is considered to be met. (PRA)

Scenario 1 D-1 Rev 0 75 Day Submittal Page 3 of 3

Facility: Clinton Power Station ILT 14-1 NRG Scenario No.: _L Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 97%.

Thunderstorms are expected in the area within the next hour.

Control Rod 12-25 is stuck at position 48 and has been hydraulically disarmed IAW CPS 3304.01 Control Rod Hydraulic and Control (RD) section 8.2.5.1 Hydraulically Disarming Stuck Withdrawn Control Rod.

Turnover:

Perform CPS 9064.01 Drywell Post-LOCA Vacuum Breaker Verification Test.

On the previous shift, the Drywell was vented per CPS 3316.01 Containment Combustible Gas Control (HG) to support performance of CPS 9064.01.

Maintain Rx Power at 97%.

Even Malt. No.

Event Type*

Event t No.

Description 1

A06_S12_ 1 Press N-BOP Drywell Vacuum Breaker Test TS-SRO 2

A01 - A01 - 02_5_TVM=2 C-ATC/SRO

'B' RWCU pump seal plate temperature high 3

YP _XMFTB_5010 c ~soP Train A Control Room Supply Fan (OVC03CA)

TS-SRO trips 4

A02_A05_01 _7 _ TVM=2 C-ATC/SRO CRD high temperature 5

N/A R-ATC/SRO EPR for Grid Load Reduction 6

YP _XMFTB_4102 I-BOP/SRO Spurious HPCS auto initiation 7

YPXMALSE_252 MSL 'D' Rupture in the Drywell/Drywell Failure I YPCTHOLE 25%

M-A TWS (Manual Scram PBs Successful) I Fig N SRO/ ATC/BOP A02_A12_S01 Run Slowdown 8

RHOVCE12F028AFP=0 C-BOP/SRO Div 1 Containment Spray Manual Initiation failure (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 2 D-1 Rev 1 75 Day Submittal Page 1 of 3

Scenario No.:....£_

Operating Test No.: 2015-301 Narrative Summary Event #

Description

1.

Drywell Vacuum Breaker Test Following shift turnover, the SRO will direct the BOP Operator to perform CPS 9064.01 Drywell Post-LOCA Vacuum Breaker Verification Test. When the BOP depresses the test pushbutton for 1 HG01 OD it will open but fail to reclose. The SRO will enter ITS 3.6.5.6 Drywell Post-LOCA Vacuum Relief System Action A.1 requiring 1 HG01 OD to be reclosed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

2.

'B' RWCU pump seal plate temperature high Annunciator CLEANUP PUMP SEAL GLAND PLATE TEMP HI (5000-2E) comes in due to RWCU Recirc Pump B (1 G33-C001 B) developing excessive seal leak requiring its removal from service. The ATC Operator will dispatch a field operator and coordinate/perform operations per CPS 3303.01 Reactor Water Cleanup (RT) Sections 8.1.3 System/Filter Demin Flow Control and 8.1.4 Removing RWCU Pump(s) From Service.

3. Train A Control Room Supply Fan (OVC03CA) trips Annunciator AUTO TRIP PUMP/FAN DIVISION 1 (5050-1A) comes in due to the Train A Control Room Supply Fan (OVC03CA) tripping. The BOP Operator will coordinate with the field operator to shift Control Room HVAC (VC) to Train B per CPS 3402.01 Section 8.1.7 Shifting Ventilation Trains. Technical Specification LCO 3.7.3 Actions A.1 will be evaluated requiring restoration of control room ventilation subsystem to an operable status within 7 days. Technical Specification LCO 3.7.4 Actions A.1 will also be evaluated requiring restoration of control room AC subsystem to an operable status within 30 days.
4.

CRD high temperature Annunciator CAD HYDR TEMP HI (5006-1G) is received. The ATC operator will dispatch a field operator to the local recorder on 1 H22-P007 to determine rod 52-25 is alarming. The ATC operator will note that rod 52-25 is currently at position 48 and IAW CPS 3304.01 CONTROL ROD HYDRAULIC & CONTROL (RD) perform an extended coupling check. The annunciator will clear for - 30 seconds and then alarm again. The ATC operator will then insert rod 52-25 to position 46 which will clear the high temperature condition.

5.

EPR for Grid Load Reduction The Transmission System Operator (TSO) will call the MCA and direct CPS to lower Generator output by 80 MWe to mitigate degraded grid conditions. IAW OP-CL-108-107-1002 Degraded Grid Actions, the SRO will direct performance of an Emergency Power Reduction. The ATC will lower power by 80 MWe within 15 minutes of the TSO request.

6.

Spurious HPCS auto initiation High Pressure Core Spray (HPCS) initiates with no operator action. IAW CPS 3309.01 HIGH PRESSURE CORE SPRAY (HPCS), the crew will verify by at least two independent indications that misoperation in automatic is confirmed or adequate core cooling is assured. Once confirmed, the SRO will direct the BOP operator to secure HPCS. Technical Specification LCO 3.5.1 Actions B.1 and B.2 will be evaluated requiring verification by administrative means that the RCIC system is operable when required AND the HPCS system is restored to operable status within 14 days.

Scenario 2 D-1 Rev I 75 Day Submittal Page 2 of 3

7.

MSL break in the Drywell / ATWS (Manual Scram PBs successful) I Fig N Slowdown The 'D' Main Steam Line will rupture inside the Drywell causing OW pressure to rise. The SRO will enter CPS 4100.01 Coolant Leakage off-normal and direct the reactor to be scrammed. When the ATC places the mode switch in shutdown, the reactor will fail to scram. The ATC will arm and depress the Manual Scram Pushbuttons and initiate ARI to successfully insert all control rods. The crew will evacuate the containment. The SRO will enter EOP-1A ATWS RPV Control. The SRO will enter EOP-6 Primary Containment Control and will direct the BOP operator to initiate containment spray when Containment pressure reaches the OK to Spray region of EOP-6 Figure 0 Containment Spray Initiation Limit. When Containment Pressure exceeds EOP-6 Figure N Pressure Suppression Pressure limit, the SRO will direct the crew to perform a reactor blowdown per EOP-3 Emergency Depressurization {Slowdown).

8.

Div 1 Containment Spray arm & depress failure EOP 1, 6, 3 When the BOP operator arms & depresses the manual pushbutton for CNMT SPRAY A MANUAL INITIATION, 1E12-F028A RHR 'A' To CNMT Spray 'A' Shutoff Viv will fail to open, requiring the BOP to manually align 1E12-F028A using the MCR control switch.

Critical tasks:

RPV-6.1 BOP/ ATC inserts control rods and/or start Standby Liquid Control Pumps to shutdown the reactor.

PC-7.1 Within 10 minutes of exceeding Figure N and containment pressure continuing to rise, the SRO will enter EOP-3 Emergency RPV Depressurization. If the crew Anticipates Slowdown using bypass valves, and in doing so Figure N is not exceeded, then this critical task is considered to be met. (PRA)

Scenario 2 D-1 Rev 1 75 Day Submittal Page 3of3

Facility: Clinton Power Station IL T 14-1 NRG Scenario No.: _L Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 97%.

Thunderstorms are expected in the area within the next hour.

MC Pump 'A' (OMC01 PA) is OOS for maintenance. Not expected back this shift.

Turnover:

Main EHC pump 1 Bis in service. Shift hydraulic pumps IAW CPS 3105.02 MAIN EHC HYDRAULIC POWER UNIT (EH) to support hanging a clearance order.

Maintain Rx Power at 97%.

Even Malt. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Shift Main EHC Pumps to support clearance order 2

A11 - A01_06_6_TVM 2 TS-SRO Inoperable ADS Accumulator Low Pressure Alarm 3

A04_A 18_A02_ 4 Manual C-BOP/SRO EHC Temperature Controller Failure A04_A 18_A02_7 Press 4

YPXMALSE_ 18 5%

R-ATC/SRO Loss of Main Generator H2 requiring power reduction 5

S_K603A 2 CLOSE SLOW C-ATC/SRO

'A' RR Flow Control Valve drifts shut 6

GSOASL V ALVE05 C-BOP/SRO Hi Pressure on the Steam Seal Header 7

ROD4413TFIA6 TS-SRO CRD HCU Accumulator Trouble (Rod 44-13) 8 YPXMALSE_528 C-ATC/SRO RR Pump 'A' Seal Failure I Emergency Loop YPXMALSE_529 Shutdown and Isolation 9

YP _XMFTB_ 4063 M-Generator Trip/ATWS BOP/SRO/ATC 10 YP _XREMT _737 C-BOP/SRO Reactor Water Cleanup System fails to isolate on SLC Pump start (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 3 D-1 Rev 0 75 Day Submittal Page 1 of 3

Scenario No.: ___1_

Operating Test No.: 2015-301 Narrative Summary Event #

Description

1. Shift Main EHC Pumps Following shift turnover, the SRO will direct the BOP operator to shift Main EHC Pumps IAW CPS 3105.02 MAIN EHC HYDRAULIC POWER UNIT (EH) section 8.1.2 Shitting Hydraulic Pumps to support hanging a clearance order.
2.

Inoperable ADS Accumulator Low Pressure Alarm Annunciator HIGH/LOW PRESS ADS IA SUPPLY DIV 1 OR 2 (5040-6F} comes in. BOP notes that Div 1/Div 2 ADS Instrument Air Hdr Press readings are normal. The SRO will evaluate Technical Specification ORM 2.2.13, Action 3.2.13.1 a) requiring verification that the ADS accumulator pressures are~ 140 psig at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and 3.2.13.1 b}

instrumentation channels are restored to OPERABLE status within 30 days and, if unsuccessful initiate a Condition Report.

3.

EHC Temperature Controller Failure Annunciator TROUBLE EHC FLUID (5017-3B) comes in due to low temperature caused by a failure in the auto portion of the EHC FLUID CLG WTR CONTROL controller. The BOP operator will diagnose the problem with the controller, place the controller in MANUAL, stabilize and restore EHC Fluid Temperature.

4.

Loss of Main Generator H2 requiring power reduction Annunciator TROUBLE GC SYSTEM LOCAL PNL 1PL1 OJ (5018-2A} comes in and an Equipment Operator (EO) is dispatched to investigate. It looked at, Main Generator H2 pressure will be slowly lowering. EO will report that Annunciators MACH GAS PRESSURE HIGH LOW (5021 -1A) and DIFF'L SEAL OIL PRESS LOW (due to a malfunction of the Delta Pressure Reg Valve/ H2 leak). The BOP will coordinate with the EO to bypass the Delta Pressure Reg Valve IAW CPS 3109.01 GENERATOR SEAL OIL (SO), stopping the leak. The loss of H2 pressure will also require the ATC to lower reactor power within the limits of CPS 3111.01 GENERATOR GAS (HY, CO) Appendix A GENERATOR ESTIMATED CAPABILITY CURVES.

5.

'A' RR Flow Control Valve (FCV) Drifts Shut The 'A' RR Flow Control Valve slowly drifts shut causing reactor power to lower, and requiring the ATC to perform an emergency shutdown of the 'A' RR Hydraulic Power Unit to stop further RR FCV movement. The crew will enter and execute CPS 4008.01 Abnormal Reactor Coolant Flow. The crew will evaluate core thermal limits by demanding a 3D Monicore Case to ensure core thermal limits are within TS limits. The crew will also evaluate RR loop flow mismatch to ensure operation within ITS 3.4.1 Recirculation Loops Operating limits.

6.

Hi Pressure on the Steam Seal Header Annunciator 5019-3D High/Low Press Stm Seal Hdr is received due to failure of valve 1 GS-SSFV Stm Seal Hdr Press Control Viv. The BOP will throttle open 1 GS-S2 Stm Seal Supply Bypass Viv and shut 1GS-S1 Stm Seal Supply Vlv*to isolate the tailed pressure control valve and restore GS Seal Header pressure to - 4 psig (2.2 psig - 4.3 psig).

7. CRD HCU Accumulator Trouble Annunciator ACCUMULATOR TROUBLE (5006-1H} is received. The ATC will determine which accumulator is alarming by depressing the ACCUM FAULT button. The ATC will then acknowledge the accumulator fault to clear the annunciator so another fault will cause an alarm. An Equipment Operator (EO) will be dispatched into the containment to determine the cause of the alarm (high level or low pressure). The EO will report that the accumulator tor rod 44-13 is at 1540 psig. IAW 5006-1 H, the SRO will declare the accumulator inoperable and will enter TS 3.1.5 Action A.1 or A.2. The CRS will consult with the RE to determine the number of control rods that are slow (O). The ATC/BOP will direct the Equipment Operator (EO) to recharge the accumulator tor control rod 44-13.

Scenario 3 D-1 Rev 0 75 Day Submittal Page 2 of 3

8.

RR Pump 'A' Seal Failure I Emergency Loop Shutdown and Isolation The inner and outer seals will fail on the 'A' RR Pump requiring the MGR crew to perform an Emergency Loop Shutdown and Isolation of the 'A' RR Loop.

9.

Generator Trip/ATWS Due to an unknown fault, the Main Generator trips. No control rod movement is observed when the ATC Operator places the mode switch in SHUTDOWN. The CRS will enter ATWS RPV Control (EOP-1A) and direct the actions of the ATC Operator and BOP Operator.

10. Reactor Water Cleanup (RWCU) System fails to isolate on SLC Pump start The RWCU system fails to automatically isolate when SLC is initiated in event 8 and the BOP will take manual actions to trip the RWCU Pumps and close 1 G33-F001 and F004.

EOP 1, 1A Critical tasks:

RPV-6.1 ATC/BOP inserts control rods and/or starts Standby Liquid Control Pumps to shutdown the reactor.

RPV-6.2 (Conditional} BOP Inhibits ADS (only if level challenges Level 1)

RPV-6.3 ATC/BOP terminates and prevents injection IAW Detail F1 to lower level to reduce subcooling or to lower level to decrease reactor power.

RPV-6.3 BOP terminates and prevents injection from HPCS.

RPV-6.4 ATC controls RPV level between TAF and -60" (PRA).

BOP trips RWCU pumps following SLC initiation.

Scenario 3 D-1 Rev 0 75 Day Submittal Page 3 of 3

Facility: Clinton Power Station IL T 14-1 NRG Scenario No.: Spare Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 83%. Power ascension is in progress.

Thunderstorms are expected in the area within the next hour.

Suppression Pool Cleanup and Transfer Pump 1 B (1 SF01 PB) is OOS for maintenance. Not expected back this shift.

Turnover:

RCIC Surveillance 9054.01 was completed last shift. RHR B is currently in Suppression Pool Cooling to support the RCIC surveillance and is no longer required. Secure Suppression Pool Cooling per CPS 3312.01 Residual Heat Removal (RHR) Section 8.1.10 - First Priority. NOTE:

RHR HX MC layup is being deferred.

Raise Reactor Power to 96% using flow.

Even Malt. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Secure from Suppression Pool Cooling 2

A05_A02_A 15DS55_ 1 = Off TS-SRO HPCS Water Leg Pump trip A05_A02_A 15DS54_ 1 = On AOS A02 A 15DS53 1 = On Aos_::-Ao2_::-Ao1 oa_3_ TvM = 2 3

N/A R-ATC/SRO Raise Power with flow to 96%

4 ROD3241 TFIA3 C-ATC Rod drifts outward TS-SRO 5

FC01BFC2PBFO C-BOP/SRO

'B' FC Pump trip 6

YP _XMFTB_ 4992 C-BOP/SRO Trip of MSOP I ESOP fails to auto start A04_A28_S23=2 7

YAFWL83 M-Feedwater Leak /RPV Leak to T AF/RCIC trips YPXMALSE_511 BOP/SRO/ATC on start-no reset YP _XMFTB_ 4960 8

YPXMALSE_76 (FV = 0)

M-During B/D, 3 SRVs fail to open YPXMALSE_87 (FV = 0)

BOP/SRO/ATC YPXMALSE_79 (FV = 0) 9 YP _XMFTB_ 4948 C-BOP/SRO RHR B Pump fails to auto start/Pump starts by handswitch manipulation (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario Spare D-1 Rev 0 75 Day Submittal Page 1of3

Scenario No.: _.1_

Operating Test No.: 2015-301 Narrative Summary Event#

Description

1.

Secure from Suppression Pool Cooling The BOP Operator will secure Suppression Pool Cooling per CPS 3312.01 Residual Heat Removal (RHR) Section 8.1.10 Suppression Pool Cooling - Shutdown.

2.

HPCS Water Leg Pump trip Annunciator HPCS WATER LEG PUMP AUTO TRIP (5062-8C) comes in due to the HPCS Water Leg Pump trip. The BOP Operator will dispatch a field operator to investigate. Upon the report of a breaker trip, the BOP operator will direct the field operator to pull the HPCS Pump Breaker control power fuses per CPS 3309.01 High Pressure Core Spray (HPCS) Precaution 4.3. Technical Specification LCO 3.5.1 Actions B.1 and 8.2 will be evaluated requiring verification by administrative means that the RCIC system is operable when required AND the HPCS system is restored to operable status within 14 days.

3.

Raise Power with flow to 96%

The crew will raise Reactor power with Recirc Flow to achieve 100% Flow Control Line IAW CPS 3005.01 Unit Power Changes.

4.

Rod drifts outward Annunciator ROD DRIFT (5006-4G) comes in due to rod 32-41 drifting outward. The ATC Operator will take the Immediate Actions and applicable Subsequent Actions as directed by the CRS tor an Inadvertent Rod Movement per CPS 4007.02 Inadvertent Rod Movement. Rod 32-41 will drift outward until individually scrammed at the Hydraulic Control Unit (HCU). Technical Specification LCO 3.1.3 Actions C.1 and C.2 will be evaluated requiring full insertion of the inoperable control rod in 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and disarming the associated CRD in 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Technical Specification LCO 3.1.6 Actions A.1 will also be evaluated and found not to apply.

5.

'B' FC Pump trip Annunciators AUTO TRIP PUMP/MOTOR DIVISION 2 (5040-1E) and TROUBLE FC SYSTEM LOCAL PNL OPL45J (5040-7D) comes in due to a trip of the 'B' Fuel Pool Cooling (FC) Pump 1 FC02PB. The BOP Operator will dispatch a field operator to investigate. Per Annunciator Response Procedure (ARP) CPS 5040.01, the BOP Operator will shut FC supply/return containment isolation valves 1 FC007, 1 FC008, 1 FC036 and 1 FC037.

6. Trip of MSOP/ESOP fails to auto start Annunciator 5017-1A AUTO TRIP TURBINE AUXILIARY PUMP/MOTOR is received due to a trip of the Main Seal Oil Pump (MSOP). Additionally the Emergency Seal Oil Pump (ESOP) will tail to auto start. The BOP Operator will review the ARP, recognize the failure of the ESOP to auto start and manually start the ESOP, and then take additional actions to align the Seal Oil system tor ESOP operation IAW CPS 3109.01 GENERATOR SEAL OIL (SO) section 8.2.1 Operation with Emergency Seal Oil Pump.
7.

Feedwater Leak /RPV Leak to TAF/RCIC trips on start-no reset An unisolable RPV leak in the lower plenum develops. The RCIC turbine will trip when started and cannot be reset. This failure completes a loss of all major high pressure teed sources. Reactor Pressure Vessel (RPV) water level will lower until it reaches Top of Active Fuel (T AF). At that time the CRS will enter EOP-3, blowdown, recover and restore RPV level per EOP-3.

8.

During BID, 3 SRVs fail to open Upon initiation of ADS, three ADS SRV's 41 F, 51 G and 47 A tail to open. The BOP operator will open three additional relief valves to complete the blow down.

9.

AHR B Pump fails to auto start/Pump starts by handswitch manipulation Scenario Spare D-1 Rev 0 75 Day Submittal Page 2 of 3

Facility: Clinton Power Station IL T 14-1 NRC Scenario No.: _1_

Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 24%. Reactor startup is in progress.

Thunderstorms are expected in the area within the next hour.

Turbine Driven Reactor Feed Pump (TDRFP) 'B' is out of service for minor maintenance.

Restoration is expected prior to transferring RR Pumps 'A' and 'B' to fast speed.

Turnover:

Cross-tie 480V Buses 1 L & 1 M with 1 L supplying per CPS 3502.01 480 VAC Distribution.

Continue reactor startup. Raise reactor power to 29% in preparation for Reactor Recirculation (RR) pump shift to fast speed.

Even Malf. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Cross-tie Unit Sub 1 L & 1 M with 1 L supplying 2

¥P--X:Mi;m 50'1.t-.

+S SR9' L-Pes Roorn Fan trip-I~

3 YFFWPPSS_ 13 C-BOP/SRO MC Pump 1 B coupling failure 4

Ai1 _A05_S40_2 ON TS-SRO Loss of Control Power to Suppression Pool A11 _A02_07_4_TVM 2 Dump Valve 1 SM001 A A 11_A08_DS30_1 OFF 5

A11 _A02_03_7_TVM 2 C-BOP/SRO Low Flo~ CW Bearing Seal Water 6

N/A A-ATC/SRO Raise power with rods to 29%

7 ROD1641TFIA5 C-ATC/SRO Uncoupled Rod 8

Y AFWPPLB_ 15 C-ATC/SRO TDRFP 'A' High Bearing Temperature 9

YP _XMFTB_5082 M-PC-12 RPV Ref Leg Leak In Gas Control BOP/SRO/ATC Boundary 10 CAM1 PR006(NB/C/D)TV _

VALUE1 = 21-24 mr A11 _A03_01 _4_TVM 4 A 11_A03_02_3_ TVM 4 A 18_A03_S11 = 1 C-BOP/SRO Radiation Monitor fails to isolate VF/Startup VG A 18_A03_S10 = 1 A12_A01 _07 _6_TVM 2 A12_A02_07_6_TVM 2 (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 1 D-1 Rev 0 75 Day Submittal Page 1 of3

Scenario No.:

1 Operating Test No.: 2015-301 Narrative Summary Event#

Description

1.

Cross-tie Unit Sub 1 L & 1 M with 1 L supplying Following shift turnover, the SRO will direct the BOP Operator to cross-tie 480V Buses 1 L

& 1 M with 1 L supplying per CPS 3502.01 480 VAC Distribution section 8.1.4 Transferring a 480V Bus: Paralleling Method.

2.

LPCS Room Fan trip Annunciator 5050-1 C Not Available VY System Division 1 will be received. The BOP operator will determine that the LPCS Supply Fan 1 VY01 C has tripped. If the BOP attempts to restart the fan, the fan will fail to start. The crew will monitor LPCS Pump Room temperature and dispatch an Equipment Operator to determine the cause of the trip. The SRO will evaluate and enter ITS 3.5.1 ECCS - Operating Required Action A.1 Restore low pressure ECCS injection/spray subsystem to OPERABLE status within 7 days.

3.

MC Pump 1 B coupling failure Annunciator LOW PRESS MAKE-UP COND XFER PUMPS DISCH HOR (5014-2C) comes in due to the Make-Up Condensate Transfer Pump 1 B (OMC01 PB) shaft shear.

The BOP Operator will dispatch a field operator to investigate. Upon the report of a shaft shear, the BOP operator will stop the failed pump and start the standby pump per CPS 3208.01 Cycled/Makeup Condensate Section 8.1.1 (or 8.2.2).

4.

Loss of Control Power to Suppression Pool Dump Valve (SM001 A)

Annunciator NOT AVAILABLE SM SYSTEM DIVISION 1 (5041-70) comes in due to a blown control power fuse deenergizing relay 74-SM1A (1SM001A Bkr Overload relay).

The BOP operator will dispatch a field operator to investigate. Technical Specification LCO 3.6.2.4, Action C.1 will be evaluated requiring the restoration of the SPMU subsystem to operable status within 7 days.

5.

Low Flow CW Bearing Seal Water Annunciator 5041-3G LOW FLOW CW PUMP 1C BRG SEAL WATER comes in due to CW Pump 'C' seal water flow less than the setpoint (15 gpm). The BOP operator will dispatch an Equipment Operator to investigate. Seal water flow to Circulating Water (CW) Pump 1 C cannot be restored requiring the BOP operator to trip CW Pump 1 C and start CW Pump 1 A.

6.

Raise power with rods to 29%

The crew will raise Reactor power with Control Rods to achieve -29% Reactor Power IAW CPS 3004.01 TURBINE STARTUP AND GENERATOR SYNCHRONIZATION in preparation for transferring RR pumps to FAST speed.

7.

Uncoupled rod When the first in-sequence control rod reaches position 48, the ATC will perform a coupling check IAW CPS 3304.02 Rod Control And Information System (RC&IS) section 8.1.10 Coupling Check by applying a continuous withdraw to the rod at position 48.

Annunciator 5006-5G Rod Overtravel will be received, indicating that the control rod has become uncoupled from its drive mechanism. The operating crew will attempt to recouple the control rod IAW the annunciator response procedure. The SRO will evaluate and enter ITS 3.1.3 Condition C until the control rod is successfully recoupled.

8.

TDRFP 'A' High Bearing Temperature Annunciator 5002-2C HIGH TEMP RFPT 1 A BRG comes in due to a failed bearing in the

'A' RFPT. With the 'B' TDRFP tagged out, the crew will start the MDRFP and secure the

'A' TDRFP IAW CPS 3103.01 Feedwater (FW) section 8.3.6 High Temperature TDRFP Bearings.

9.

RPV Instrument Line leak Scenario 1 D-1 Rev 0 75 Day Submittal Page 2 of 3

An RPV instrument line will break resulting in a partial loss of RPV instrumentation, a steam leak in the secondary containment and EOP-8 entry. Two areas in secondary containment will exceed Maximum Safe temperature requiring blowdown. The crew may Anticipate Slowdown using bypass valves prior to two areas reaching max safe.

10. Radiation Monitor fails to isolate VF/Startup VG EOP 8, 1, 3 Due to the RPV instrument line leak in the secondary containment, the VF exhaust radiation monitors trend up to the trip isolation set point but fail to actuate VF system isolation and start of VG requiring BOP to manually perform.

Critical tasks:

SC-1.1 ATC inserts a manual Scram before area temperature reaches max safe in any one area.

SC-1.2 SRO enters EOP-3 and performs a blowdown when 2 or more areas are above the max safe value of the same parameter (Table T, U, W), and a Primary System is discharging into the Secondary Containment, which cannot be isolated. If the crew Anticipates Slowdown using bypass valves, and in doing so two areas do not reach a max safe condition, then this critical task is considered to be met. (PRA)

Scenario 1 D-1 Rev 0 75 Day Submittal Page 3 of 3

Facility: Clinton Power Station ILT 14-1 NRG Scenario No.: _L Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 97%.

Thunderstorms are expected in the area within the next hour.

Control Rod 12-25 is stuck at position 48 and has been hydraulically disarmed IAW CPS 3304.01 Control Rod Hydraulic and Control (RD) section 8.2.5.1 Hydraulically Disarming Stuck Withdrawn Control Rod.

Turnover:

Perform CPS 9064.01 Drywell Post-LOCA Vacuum Breaker Verification Test.

On the previous shift, the Drywell was vented per CPS 3316.01 Containment Combustible Gas Control (HG) to support performance of CPS 9064.01.

Maintain Rx Power at 97%.

Even Malt. No.

Event Type*

Event t No.

Description 1

A06_S12_ 1 Press N-BOP Drywell Vacuum Breaker Test TS-SRO 2

A01 - A01 - 02_5_TVM=2 C-ATC/SRO

'B' RWCU pump seal plate temperature high 3

YP _XMFTB_5010 c ~soP Train A Control Room Supply Fan (OVC03CA)

TS-SRO trips 4

A02_A05_01 _7 _ TVM=2 C-ATC/SRO CRD high temperature 5

N/A R-ATC/SRO EPR for Grid Load Reduction 6

YP _XMFTB_4102 I-BOP/SRO Spurious HPCS auto initiation 7

YPXMALSE_252 MSL 'D' Rupture in the Drywell/Drywell Failure I YPCTHOLE 25%

M-A TWS (Manual Scram PBs Successful) I Fig N SRO/ ATC/BOP A02_A12_S01 Run Slowdown 8

RHOVCE12F028AFP=0 C-BOP/SRO Div 1 Containment Spray Manual Initiation failure (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 2 D-1 Rev 1 75 Day Submittal Page 1 of 3

Scenario No.:....£_

Operating Test No.: 2015-301 Narrative Summary Event #

Description

1.

Drywell Vacuum Breaker Test Following shift turnover, the SRO will direct the BOP Operator to perform CPS 9064.01 Drywell Post-LOCA Vacuum Breaker Verification Test. When the BOP depresses the test pushbutton for 1 HG01 OD it will open but fail to reclose. The SRO will enter ITS 3.6.5.6 Drywell Post-LOCA Vacuum Relief System Action A.1 requiring 1 HG01 OD to be reclosed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

2.

'B' RWCU pump seal plate temperature high Annunciator CLEANUP PUMP SEAL GLAND PLATE TEMP HI (5000-2E) comes in due to RWCU Recirc Pump B (1 G33-C001 B) developing excessive seal leak requiring its removal from service. The ATC Operator will dispatch a field operator and coordinate/perform operations per CPS 3303.01 Reactor Water Cleanup (RT) Sections 8.1.3 System/Filter Demin Flow Control and 8.1.4 Removing RWCU Pump(s) From Service.

3. Train A Control Room Supply Fan (OVC03CA) trips Annunciator AUTO TRIP PUMP/FAN DIVISION 1 (5050-1A) comes in due to the Train A Control Room Supply Fan (OVC03CA) tripping. The BOP Operator will coordinate with the field operator to shift Control Room HVAC (VC) to Train B per CPS 3402.01 Section 8.1.7 Shifting Ventilation Trains. Technical Specification LCO 3.7.3 Actions A.1 will be evaluated requiring restoration of control room ventilation subsystem to an operable status within 7 days. Technical Specification LCO 3.7.4 Actions A.1 will also be evaluated requiring restoration of control room AC subsystem to an operable status within 30 days.
4.

CRD high temperature Annunciator CAD HYDR TEMP HI (5006-1G) is received. The ATC operator will dispatch a field operator to the local recorder on 1 H22-P007 to determine rod 52-25 is alarming. The ATC operator will note that rod 52-25 is currently at position 48 and IAW CPS 3304.01 CONTROL ROD HYDRAULIC & CONTROL (RD) perform an extended coupling check. The annunciator will clear for - 30 seconds and then alarm again. The ATC operator will then insert rod 52-25 to position 46 which will clear the high temperature condition.

5.

EPR for Grid Load Reduction The Transmission System Operator (TSO) will call the MCA and direct CPS to lower Generator output by 80 MWe to mitigate degraded grid conditions. IAW OP-CL-108-107-1002 Degraded Grid Actions, the SRO will direct performance of an Emergency Power Reduction. The ATC will lower power by 80 MWe within 15 minutes of the TSO request.

6.

Spurious HPCS auto initiation High Pressure Core Spray (HPCS) initiates with no operator action. IAW CPS 3309.01 HIGH PRESSURE CORE SPRAY (HPCS), the crew will verify by at least two independent indications that misoperation in automatic is confirmed or adequate core cooling is assured. Once confirmed, the SRO will direct the BOP operator to secure HPCS. Technical Specification LCO 3.5.1 Actions B.1 and B.2 will be evaluated requiring verification by administrative means that the RCIC system is operable when required AND the HPCS system is restored to operable status within 14 days.

Scenario 2 D-1 Rev I 75 Day Submittal Page 2 of 3

7.

MSL break in the Drywell / ATWS (Manual Scram PBs successful) I Fig N Slowdown The 'D' Main Steam Line will rupture inside the Drywell causing OW pressure to rise. The SRO will enter CPS 4100.01 Coolant Leakage off-normal and direct the reactor to be scrammed. When the ATC places the mode switch in shutdown, the reactor will fail to scram. The ATC will arm and depress the Manual Scram Pushbuttons and initiate ARI to successfully insert all control rods. The crew will evacuate the containment. The SRO will enter EOP-1A ATWS RPV Control. The SRO will enter EOP-6 Primary Containment Control and will direct the BOP operator to initiate containment spray when Containment pressure reaches the OK to Spray region of EOP-6 Figure 0 Containment Spray Initiation Limit. When Containment Pressure exceeds EOP-6 Figure N Pressure Suppression Pressure limit, the SRO will direct the crew to perform a reactor blowdown per EOP-3 Emergency Depressurization {Slowdown).

8.

Div 1 Containment Spray arm & depress failure EOP 1, 6, 3 When the BOP operator arms & depresses the manual pushbutton for CNMT SPRAY A MANUAL INITIATION, 1E12-F028A RHR 'A' To CNMT Spray 'A' Shutoff Viv will fail to open, requiring the BOP to manually align 1E12-F028A using the MCR control switch.

Critical tasks:

RPV-6.1 BOP/ ATC inserts control rods and/or start Standby Liquid Control Pumps to shutdown the reactor.

PC-7.1 Within 10 minutes of exceeding Figure N and containment pressure continuing to rise, the SRO will enter EOP-3 Emergency RPV Depressurization. If the crew Anticipates Slowdown using bypass valves, and in doing so Figure N is not exceeded, then this critical task is considered to be met. (PRA)

Scenario 2 D-1 Rev 1 75 Day Submittal Page 3of3

Facility: Clinton Power Station IL T 14-1 NRG Scenario No.: _L Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 97%.

Thunderstorms are expected in the area within the next hour.

MC Pump 'A' (OMC01 PA) is OOS for maintenance. Not expected back this shift.

Turnover:

Main EHC pump 1 Bis in service. Shift hydraulic pumps IAW CPS 3105.02 MAIN EHC HYDRAULIC POWER UNIT (EH) to support hanging a clearance order.

Maintain Rx Power at 97%.

Even Malt. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Shift Main EHC Pumps to support clearance order 2

A11 - A01_06_6_TVM 2 TS-SRO Inoperable ADS Accumulator Low Pressure Alarm 3

A04_A 18_A02_ 4 Manual C-BOP/SRO EHC Temperature Controller Failure A04_A 18_A02_7 Press 4

YPXMALSE_ 18 5%

R-ATC/SRO Loss of Main Generator H2 requiring power reduction 5

S_K603A 2 CLOSE SLOW C-ATC/SRO

'A' RR Flow Control Valve drifts shut 6

GSOASL V ALVE05 C-BOP/SRO Hi Pressure on the Steam Seal Header 7

ROD4413TFIA6 TS-SRO CRD HCU Accumulator Trouble (Rod 44-13) 8 YPXMALSE_528 C-ATC/SRO RR Pump 'A' Seal Failure I Emergency Loop YPXMALSE_529 Shutdown and Isolation 9

YP _XMFTB_ 4063 M-Generator Trip/ATWS BOP/SRO/ATC 10 YP _XREMT _737 C-BOP/SRO Reactor Water Cleanup System fails to isolate on SLC Pump start (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario 3 D-1 Rev 0 75 Day Submittal Page 1 of 3

Scenario No.: ___1_

Operating Test No.: 2015-301 Narrative Summary Event #

Description

1. Shift Main EHC Pumps Following shift turnover, the SRO will direct the BOP operator to shift Main EHC Pumps IAW CPS 3105.02 MAIN EHC HYDRAULIC POWER UNIT (EH) section 8.1.2 Shitting Hydraulic Pumps to support hanging a clearance order.
2.

Inoperable ADS Accumulator Low Pressure Alarm Annunciator HIGH/LOW PRESS ADS IA SUPPLY DIV 1 OR 2 (5040-6F} comes in. BOP notes that Div 1/Div 2 ADS Instrument Air Hdr Press readings are normal. The SRO will evaluate Technical Specification ORM 2.2.13, Action 3.2.13.1 a) requiring verification that the ADS accumulator pressures are~ 140 psig at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and 3.2.13.1 b}

instrumentation channels are restored to OPERABLE status within 30 days and, if unsuccessful initiate a Condition Report.

3.

EHC Temperature Controller Failure Annunciator TROUBLE EHC FLUID (5017-3B) comes in due to low temperature caused by a failure in the auto portion of the EHC FLUID CLG WTR CONTROL controller. The BOP operator will diagnose the problem with the controller, place the controller in MANUAL, stabilize and restore EHC Fluid Temperature.

4.

Loss of Main Generator H2 requiring power reduction Annunciator TROUBLE GC SYSTEM LOCAL PNL 1PL1 OJ (5018-2A} comes in and an Equipment Operator (EO) is dispatched to investigate. It looked at, Main Generator H2 pressure will be slowly lowering. EO will report that Annunciators MACH GAS PRESSURE HIGH LOW (5021 -1A) and DIFF'L SEAL OIL PRESS LOW (due to a malfunction of the Delta Pressure Reg Valve/ H2 leak). The BOP will coordinate with the EO to bypass the Delta Pressure Reg Valve IAW CPS 3109.01 GENERATOR SEAL OIL (SO), stopping the leak. The loss of H2 pressure will also require the ATC to lower reactor power within the limits of CPS 3111.01 GENERATOR GAS (HY, CO) Appendix A GENERATOR ESTIMATED CAPABILITY CURVES.

5.

'A' RR Flow Control Valve (FCV) Drifts Shut The 'A' RR Flow Control Valve slowly drifts shut causing reactor power to lower, and requiring the ATC to perform an emergency shutdown of the 'A' RR Hydraulic Power Unit to stop further RR FCV movement. The crew will enter and execute CPS 4008.01 Abnormal Reactor Coolant Flow. The crew will evaluate core thermal limits by demanding a 3D Monicore Case to ensure core thermal limits are within TS limits. The crew will also evaluate RR loop flow mismatch to ensure operation within ITS 3.4.1 Recirculation Loops Operating limits.

6.

Hi Pressure on the Steam Seal Header Annunciator 5019-3D High/Low Press Stm Seal Hdr is received due to failure of valve 1 GS-SSFV Stm Seal Hdr Press Control Viv. The BOP will throttle open 1 GS-S2 Stm Seal Supply Bypass Viv and shut 1GS-S1 Stm Seal Supply Vlv*to isolate the tailed pressure control valve and restore GS Seal Header pressure to - 4 psig (2.2 psig - 4.3 psig).

7. CRD HCU Accumulator Trouble Annunciator ACCUMULATOR TROUBLE (5006-1H} is received. The ATC will determine which accumulator is alarming by depressing the ACCUM FAULT button. The ATC will then acknowledge the accumulator fault to clear the annunciator so another fault will cause an alarm. An Equipment Operator (EO) will be dispatched into the containment to determine the cause of the alarm (high level or low pressure). The EO will report that the accumulator tor rod 44-13 is at 1540 psig. IAW 5006-1 H, the SRO will declare the accumulator inoperable and will enter TS 3.1.5 Action A.1 or A.2. The CRS will consult with the RE to determine the number of control rods that are slow (O). The ATC/BOP will direct the Equipment Operator (EO) to recharge the accumulator tor control rod 44-13.

Scenario 3 D-1 Rev 0 75 Day Submittal Page 2 of 3

8.

RR Pump 'A' Seal Failure I Emergency Loop Shutdown and Isolation The inner and outer seals will fail on the 'A' RR Pump requiring the MGR crew to perform an Emergency Loop Shutdown and Isolation of the 'A' RR Loop.

9.

Generator Trip/ATWS Due to an unknown fault, the Main Generator trips. No control rod movement is observed when the ATC Operator places the mode switch in SHUTDOWN. The CRS will enter ATWS RPV Control (EOP-1A) and direct the actions of the ATC Operator and BOP Operator.

10. Reactor Water Cleanup (RWCU) System fails to isolate on SLC Pump start The RWCU system fails to automatically isolate when SLC is initiated in event 8 and the BOP will take manual actions to trip the RWCU Pumps and close 1 G33-F001 and F004.

EOP 1, 1A Critical tasks:

RPV-6.1 ATC/BOP inserts control rods and/or starts Standby Liquid Control Pumps to shutdown the reactor.

RPV-6.2 (Conditional} BOP Inhibits ADS (only if level challenges Level 1)

RPV-6.3 ATC/BOP terminates and prevents injection IAW Detail F1 to lower level to reduce subcooling or to lower level to decrease reactor power.

RPV-6.3 BOP terminates and prevents injection from HPCS.

RPV-6.4 ATC controls RPV level between TAF and -60" (PRA).

BOP trips RWCU pumps following SLC initiation.

Scenario 3 D-1 Rev 0 75 Day Submittal Page 3 of 3

Facility: Clinton Power Station IL T 14-1 NRG Scenario No.: Spare Operating Test No.: 2015-301 Examiners:

Operators:

Initial Conditions:

Mode 1 Rx Power at 83%. Power ascension is in progress.

Thunderstorms are expected in the area within the next hour.

Suppression Pool Cleanup and Transfer Pump 1 B (1 SF01 PB) is OOS for maintenance. Not expected back this shift.

Turnover:

RCIC Surveillance 9054.01 was completed last shift. RHR B is currently in Suppression Pool Cooling to support the RCIC surveillance and is no longer required. Secure Suppression Pool Cooling per CPS 3312.01 Residual Heat Removal (RHR) Section 8.1.10 - First Priority. NOTE:

RHR HX MC layup is being deferred.

Raise Reactor Power to 96% using flow.

Even Malt. No.

Event Type*

Event t No.

Description 1

N/A N-BOP/SRO Secure from Suppression Pool Cooling 2

A05_A02_A 15DS55_ 1 = Off TS-SRO HPCS Water Leg Pump trip A05_A02_A 15DS54_ 1 = On AOS A02 A 15DS53 1 = On Aos_::-Ao2_::-Ao1 oa_3_ TvM = 2 3

N/A R-ATC/SRO Raise Power with flow to 96%

4 ROD3241 TFIA3 C-ATC Rod drifts outward TS-SRO 5

FC01BFC2PBFO C-BOP/SRO

'B' FC Pump trip 6

YP _XMFTB_ 4992 C-BOP/SRO Trip of MSOP I ESOP fails to auto start A04_A28_S23=2 7

YAFWL83 M-Feedwater Leak /RPV Leak to T AF/RCIC trips YPXMALSE_511 BOP/SRO/ATC on start-no reset YP _XMFTB_ 4960 8

YPXMALSE_76 (FV = 0)

M-During B/D, 3 SRVs fail to open YPXMALSE_87 (FV = 0)

BOP/SRO/ATC YPXMALSE_79 (FV = 0) 9 YP _XMFTB_ 4948 C-BOP/SRO RHR B Pump fails to auto start/Pump starts by handswitch manipulation (N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor Scenario Spare D-1 Rev 0 75 Day Submittal Page 1of3

Scenario No.: _.1_

Operating Test No.: 2015-301 Narrative Summary Event#

Description

1.

Secure from Suppression Pool Cooling The BOP Operator will secure Suppression Pool Cooling per CPS 3312.01 Residual Heat Removal (RHR) Section 8.1.10 Suppression Pool Cooling - Shutdown.

2.

HPCS Water Leg Pump trip Annunciator HPCS WATER LEG PUMP AUTO TRIP (5062-8C) comes in due to the HPCS Water Leg Pump trip. The BOP Operator will dispatch a field operator to investigate. Upon the report of a breaker trip, the BOP operator will direct the field operator to pull the HPCS Pump Breaker control power fuses per CPS 3309.01 High Pressure Core Spray (HPCS) Precaution 4.3. Technical Specification LCO 3.5.1 Actions B.1 and 8.2 will be evaluated requiring verification by administrative means that the RCIC system is operable when required AND the HPCS system is restored to operable status within 14 days.

3.

Raise Power with flow to 96%

The crew will raise Reactor power with Recirc Flow to achieve 100% Flow Control Line IAW CPS 3005.01 Unit Power Changes.

4.

Rod drifts outward Annunciator ROD DRIFT (5006-4G) comes in due to rod 32-41 drifting outward. The ATC Operator will take the Immediate Actions and applicable Subsequent Actions as directed by the CRS tor an Inadvertent Rod Movement per CPS 4007.02 Inadvertent Rod Movement. Rod 32-41 will drift outward until individually scrammed at the Hydraulic Control Unit (HCU). Technical Specification LCO 3.1.3 Actions C.1 and C.2 will be evaluated requiring full insertion of the inoperable control rod in 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and disarming the associated CRD in 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Technical Specification LCO 3.1.6 Actions A.1 will also be evaluated and found not to apply.

5.

'B' FC Pump trip Annunciators AUTO TRIP PUMP/MOTOR DIVISION 2 (5040-1E) and TROUBLE FC SYSTEM LOCAL PNL OPL45J (5040-7D) comes in due to a trip of the 'B' Fuel Pool Cooling (FC) Pump 1 FC02PB. The BOP Operator will dispatch a field operator to investigate. Per Annunciator Response Procedure (ARP) CPS 5040.01, the BOP Operator will shut FC supply/return containment isolation valves 1 FC007, 1 FC008, 1 FC036 and 1 FC037.

6. Trip of MSOP/ESOP fails to auto start Annunciator 5017-1A AUTO TRIP TURBINE AUXILIARY PUMP/MOTOR is received due to a trip of the Main Seal Oil Pump (MSOP). Additionally the Emergency Seal Oil Pump (ESOP) will tail to auto start. The BOP Operator will review the ARP, recognize the failure of the ESOP to auto start and manually start the ESOP, and then take additional actions to align the Seal Oil system tor ESOP operation IAW CPS 3109.01 GENERATOR SEAL OIL (SO) section 8.2.1 Operation with Emergency Seal Oil Pump.
7.

Feedwater Leak /RPV Leak to TAF/RCIC trips on start-no reset An unisolable RPV leak in the lower plenum develops. The RCIC turbine will trip when started and cannot be reset. This failure completes a loss of all major high pressure teed sources. Reactor Pressure Vessel (RPV) water level will lower until it reaches Top of Active Fuel (T AF). At that time the CRS will enter EOP-3, blowdown, recover and restore RPV level per EOP-3.

8.

During BID, 3 SRVs fail to open Upon initiation of ADS, three ADS SRV's 41 F, 51 G and 47 A tail to open. The BOP operator will open three additional relief valves to complete the blow down.

9.

AHR B Pump fails to auto start/Pump starts by handswitch manipulation Scenario Spare D-1 Rev 0 75 Day Submittal Page 2 of 3