Oct.

15, 2015 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSHITTAL 2015-41364 USER INFORMATION:

GERLACH*ROSEY N EMPL# :028401 CA# :

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY M 10/15/2 015 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no T0C will be issued with the updated material.

TRMl TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 10/05/2015 ADD MANUAL TABLE OF CONTENTS DATE: 10/14/2015 CATEGORY:

DOCUMENTS TYPE: TRM1 pt0t

'V

Oct.

15, 2015 Page 2

of 2

ID:

TEXT 3.3.4 REMOVE:

REV:7 ADD:

REV:

8 CATEGORY:

DOCUMENTS TYPE: TRM1 ID:

TEXT B3.3.4 ADD:

REV:

5 REMOVE:

REV: 4 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE: TRMI LOES REV: 82 ADD:

REV:

83 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
  • SES MANUAL Manual an~e:

TEMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:

10/ 14/2 015 Procedure Name Rev Issue Date TEXT LOES 83 10/14/2015

Title:

LIST OF EFFECTIVE SECTIONS Change ID Change Number TEXT TOC

Title:

25 04/28/2015 TABLE OF CONTENTS TEXT 1.1 1

01/31/2014 Til:USE AND APPLICATION DEFINITIONS TEXT 2.1 2

04/28/2015

Title:

PLANT PROGRAMS AND SETPOINTS PLANT-PROGRAMS° TEXT 2.2 10 7 °°0!/31/2014*

Title:

PLANT PROGRAMS AND SETP0ONTS ILNSTRUMENT TRIP SETPOINT TABLE TEXT 3.0

Title:

-**5*,

03705/2015 TECHNICAL REQUIREMENT F9R OPERATION (TRO) APPLICABILITY & SURVEILLANCE (TRS)

APPLICABILITY TET.11-1 11/09/2007 Title : REACTIVITY iCONqTROLh SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION I*ATWS-ARI )

INSTRUMENTATION TEXT 3.1.2 i

"*0 11/18/2002

Title:

REACTIVITY*ICONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3 5

04/16/2009

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0

11/18/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &

CHECK VALVE TEXT 3.2.1 15 04/28/2015

Title:

CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 16 Report Date: 10/15/15 Page !

of 16 Report Date: 10/15/15

SSES MANTJAT Manual Name:*

TRM1

  • iManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1 0

11/18/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4

Title:

INSTRUMENTATION 8

10/14/2015 TEN POST-ACCIDENT MONITORING INSTRUMENTATION LDCN 4552 TEXT 3.3.5 0

11/18/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3.3.6 4

04/29/2014

Title:

INSTRUMENTATION TEN ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 1

11/09/2007

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1

10/22/2003

Title:

INSTRUMENTATION TRM RPS INSTRUMENTATION TEXT 3.3.9 3

04/17/2008

Title:

OPEN INSTRUMENTATION CONFIGURATION TEXT 3.3.10 1

12/14/2004

Title:

INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015 S

Title:

WATER MONITORING INSTRUMENTATION 0

Page 2 of 16 Report Date: 10/15/15 Page 2 of 16 Report Date: 10/15/15

RSES MANUqAL Manual Namne:

TRMIl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.4.1

Title:

REACTOR TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.5.1 1

04/26/2006 COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM STRUCTURAL INTEGRITY 1

11/09/2007 COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS 2

04/17/2008 COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 1

04/26/2006 COOLANT SYSTEM REACTOR VESSEL MATERIALS 2

04/25/2013 RECIRCULATION SINGLE LOOP OPERATION SLO FLoW RATE RESTRICTION 1

02/04/2005

Title:

EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/18/2002

Title:

EMERGENCy CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/18/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3..6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/18/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page.3 of 16 Report Date: 10/15/15 Page.3 of i_66 Report Date: 10/15/15

SSES MANUJAIL Manual Name:*

TRMI

  • .Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.6.4 0

11/18/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1

Title:

PLANT TEXT 3.7.2

Title:

PLANT TEXT 3.7.3.1

Title:

PLANT TEXT 3.7.3.2

Title:

PLANT TEXT 3.7.3.3

Title:

PLANT TEXT 3.7.3.4

Title:

PLANT 0

11/18/2002 SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN 0

11/18/2002 SYSTEMS ULTIMATE HEAT SINK CUBS)

AND GROUND WATER LEVEL 2

04/16/2009 SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM 3

04/16/2009 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 04/16/2009 0

3 SYSTEMS C02 SYSTEMS 2

04/16/2009 SYSTEMS HALON SYSTEMS TEXT 3.7.3.5 2

04/16/2009

Title:

PLANT SYSTEMS FIRE HOSE STATIONS TEXT 3.7.3.6

Title:

PLANT TEXT 3.7.3.7

Title:

PLANT 2

04/16/2009 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 1

04/26/2006 SYSTEMS FIRE RATED ASSEMBLIES TEXT 3.7.3.8 10 09/27/2012

Title:

PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION TEXT 3.7.4 1

04/26/2006

Title:

PLANT SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 16 Report Date: 10/15/15 Page 4 of 16 Report Date* 10/15/15

M..i*

  • anual Name:

TRM1 SManual

Title:

TECHNICAL REQUIREMENTS MANU~IAL UNIT 1 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/18/2002

Title:

PLANT SYSTEMS MAIN CONDENSEROFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING S.TEXT 3.7.8 5

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 2

01/31/2014

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 1

12/14/2004 Ti~le: PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.11 0

04/16/2009

Title:

STRUCTURAL INTEGRITY TEXT 3.8.1 2

04/05/2010

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION CONTINUOUS h

TEXT 3.8.2.2 2

12/14/2004 F.

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMVAL OVERLOAD PROTECTION AUTOMATIC Pae/o 6RprtDt:1/51 Page

  • of 16 Report Date: 1,0/15/15

SSES MANTTAI Manual N~ame:

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANU]TAL UNIT 1 TEXT 3.8.3 Title : ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7 2

03/05,/20*15 POWER DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/18/2002 POWER 24 VTDC ELECTRICAL POWER SUBSYSTEM 1 '

11/14/2013 POWER DEGRADED VOLTAGE PROTECTION

  • 1 12/08/2011 POWER EMERGENCY SWITCHGEAR ROOM COOLING
  • 1 06/15/2009

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9.1 0

11/18/20026

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/18/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/18/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006

Title:

MISCELLANEOUS SEAL SOURCE CONTAMINATION

'TEXT 3.10.2 2

08/08/2006

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 2

04/17/2008

  • Title: MISCELLANEOUS LEADING EDGE FLOW M~ETER (LEFM)6 Page 6 of i_66 Report Date: 10/15/15

SSES MANUAL*

O *Manual Name:

TRM1 W:*

Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.1

Title:

RADIOACTIVE TEXT 3.11.1.2

Title:

RADIOACTIVE TEXT 3.11.1.3

Title:

RADIOACTIVE TEXT 3.11.1.4

Title:

RADIOACTIVE TEXT 3.11.1.5

Title:

RADIOACTIVE TEXT 3.11.2.1

Title:

RADIOACTIVE TEXT 3.11.2.2

Title:

RADIOACTIVE TEXT 3.11.2.3

Title:

RADIOACTIVE FORM TEXT 3.11.2.4

Title:

RADIOACTIVE.

TEXT 3.11.2.5

Title:

RADIOACTIVE TEXT 3.11.2.6

Title:

RADIOACTIVE TEXT 3.11.3

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1

04/26/2006 LIQUID EFFLUENTS CONCENTRATION 1

04/26/2006 LIQUID EFFLUENTS DOSE 1

04/26/2006 LIQUID WASTE TREATMENT SYSTEM 2

10/09/2012 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION

.3 03/05/2015 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 3

04/26/2006 DOSE RATE 1

04/26/2006 DOSE -

NOBLE GASES 1

04/26/2006 DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE 0

11/18/2002 GASEOUS RADWASTE TREATMENT SYSTEM 4

07/03/2013 VENTILATION EXHAUST TREATMENT SYSTEM 5

04/28/2015 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION 1

04/26/2006 TOTAL DOSE Page 2 of 16 Report Date: 10/15/15 Page 7--

of i__66 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRMI i Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.4.1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1 0

11-/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT 4.1

Title:

TEXT 4.2

Title:

TEXT 4.3

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

0 08/31/1998 ADMINISTRATIVE CONTROLS ORGANIZATION ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

08/31/1998 CONTROLS REPORTABLE EVENT ACTION 0

08/31/1998 CONTROLS SAFETY LIMIT VIOLATION 1

12/18/2008 CONTROLS PROCEDURES & PROGRAMS 0

08/31/1998 CONTROLS REPORTING REQUIREMENTS 0

08/31/1998 CONTROLS RADIATION PROTECTION PROGRAM Page 8 of 16 Report Date: 10/15/15 Page of 16 Report Date: 10/15/15

SSES M~ANUAL Manual Name :

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4.7 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS TRAINING TEXT B3.0 5

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION CTRO)

APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT B3.1.3 3

03/31/2006

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.1 0

11/19/2002

Title:

CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)

TEXT B3.3.1

Title:

INSTRUMENTATION TEXT B3.3.2

Title:

INSTRUMENTATION TEXT B3.3.3

Title:

INSTRUMENTATION TEXT B3.3.4

Title:

INSTRUMENTATION TEXT B3.3.5

Title:

INSTRUMENTATION 1

01/31/2014 BASES RADIATION MONITORING INSTRUMENTATION 2

03/31/2011 BASES SEISMIC MONITORING INSTRUMENTATION 3

12/18/2008 BASES METEOROLOGICAL MONITORING INSTRUMENTATION 5

10/14/2015 BASES TRN POST ACCIDENT MONITORING (PAN)

INSTRUMENTATION LDCN 4552 2

11/09/2007 BASES THIS PAGE INTENTIONALLY LEFT BLANK Pages of 16 Report Date: 10/15/15 Page 9--

of 166 Report Date: 10/15/15

SSES MA1~1TJAL Manual Name :

TRMI

-Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.3.6

Title:

INSTRUMENTATION BASES 5

01/31/2014 TRN ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7 1

11/09/2007

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22./2003

Title:

INSTRUMENTATION BASES TEN REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION TEXT B3.3.9

Title:

OPEN INSTRUMIENTATION TEXT B3o3.10

Title:

INSTRUMENTATION BASES STEXT B3.3.11

Title:

INSTRUMENTATION BASES TEXT B3.3.12 3

04/17/2008 3

08/09/2010 REACTOR RECIRCULATION PUMP MG SET STOPS 1

10/22/2003 MVP ISOLATION INSTRUMENTATION 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1

Title:

REACTOR TEXT B3.4.2

Title:

REACTOR TEXT B3o4.3

Title:

REACTOR TEXT B3.4.4

Title:

REACTOR TEXT B3.4.5

Title:

REACTOR 0

11/19/2002 COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM BASES STRUCTURAL INTEGRITY 1

11/09/2007 COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR 0

11/19/2002 COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 0

11/19/2002 COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 10 of 16 Report Date: 10/15/15 Page 100 of 16 Report Date: 10/15/15

S~ES MANUAL Manual Name:

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.4.6 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW PATE RESTRICTION TEXT B3.5.1 0

11/19/2002

Title:

ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 1*

11/09/2007

Title:

ECCS AND RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMETATION TEXT B3.5.3 1

11/09/2007

Title:

ECCS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2

04/17/2008

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1 0

11/19/2002

Title:

PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)

TEXT B3.7.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UIES)

GROUND WATER LEVEL TEXT B3.7.3.1 3

06/15/2010

Title:

PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM STEXT B3.7.3.2 2

04/26/2006 i

Title:

PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS Page i!i of 16 Report Date: 10/15/15

SSES MANUJAI Manual flame:

TRMI

'- Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 0

TEXT B3.7.3.3

Title:

PLANT TEXT B3.7.3.4

Title:

PLANT TEXT B3..7.3.5 Title : PLANT TEXT B3.7.3.6 Title : PLANT TEXT B3.7.3.7 Title :

PLANT TEXT B3 7.3.8 Title : PLANT TEXT B3.7.4 Title :

PLANT TEXT B3.7.5.1 Title :

PLANT TEXT B3.7.5.2 Title : PLANT TEXT B3.7.5.3 Title : PLANT TEXT B3.7.6

Title:

PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0

11/19/2002 C02 SYSTEMS 3

04/29/2014 HALON SYSTEMS 1

04/26/2006 FIRE HOSE STATIONS 1

04/26/2006 YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 FIRE RATED ASSEMBLIES 3

09/27/2012 FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SOLID RADWASTE SYSTEM 0

11/19/2002 MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/19/2002 MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002 LIQUID HOLDUP TANKS 4

06/04/2013 ESSW PUMPHOUSE VENTILATION 2

01/31/2008 TEXT B3.7.7

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION-MONITORING INSTRUMENTATION Page 12 of 16 Report Date: 10/15/15

SSES MAAL Manual Name:

TEdKI I: Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.8

Title:

PLANT TEXT B3.7.9

Title:

PLANT TEXT B3.7.10

Title:

PLANT 4

SNUBBERS 01/3 1/2 014 SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 2

12/08/2011 CONTROL STRUCTURE HVAC 1

12/14/2004 SPENT FUEL STORAGE POOLS TEXT B3.7.11

Title:

STRUCTURAL INTEGRITY 1

04/14/2010 TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL TEXT B3.8.5

Title:

ELECTRICAL TEXT B3.8.6

Title:

ELECTRICAL TEXT B3.8.7 2

03/10/2010 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 1

09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 0

11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 1

11/14/2013 POWER BASES DEGRADED VOLTAGE PROTECTION 2

12/08/2011 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 2

06/04/2013 PROTECTION -

PROTECTION -

Titles BATTERY MAINTENANCE AND MONITORING PROGRAM Page 13 of 16 Report Date: 10/15/15 Page i__33 of 16 Report Date: 10/15/15

SSES MANTJAI Manual Name :

TRMI

  • Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1

03/31/2006

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.10.4 1

04/17/2008

Title:

MISCELLANEOUS BASES LEADING EDGE FLOW METER (LEFM)

TEXT B3

.11.1.

Title:

RADIOACTIVE TEXT B3.11.1.2

Title:

RADIOACTIVE TEXT B3.11.1.3

Title:

RADIOACTIVE TEXT B3.11.1.4

Title:

RADIOACTIVE 0

11/19/2002 BASES LIQUID EFFLUENTS CONCENTRATION EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 0

BASES 11/19/2 002 LIQUID EFFLUENTS DOSE 0

11/19/2002 BASES LIQUID WASTE TREATMENT SYSTEM 0

11/19/2002 BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION Page 14 of 16 Report Date: 10/15/15 Page IA4 of 16 Report Date: 10/15/15

SSE~S MANUAL O ~iManual Name:

TRMI W**

Manual

Title:

TECHNICAL REQUIRETMENTS MANUAL UNIT 1 TEXT B3.11.2.1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

NOBLE GASES TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM TEXT B3.11.2.4

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.12.1

Title:

LOADS CONTROL PROGRAM TEXT B3.12.2

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 BASES DOSE -IODINE,

TRITIUM, AND RADIONUCLIDES IN 0

11/19/2002 BASES GASEOUS RADWASTE TREATMENT SYSTEM 5

07/03/2013 BASES VENTILATION EXHAUST 1

01/27/2004 BASES RADIOACTIVE GASEOUS TREATMNT SYSTEM EFFLUENT MONITORING 0

11/19/2002 BASES TOTAL DOSE 5

03/05/2015 BASES MONITORING PROGRAM 0

11/19/2002 BASES LAND USE CENSUS 0

11/19/2002 BASES INTERLABORATORY COMPARISON PROGRAM 1

10/04/2007 BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL 1

12/03/2010 BASES HEAVY LOADS REQUIREMENTS Page i5~

of 16 Report Date: 10/15/15 Page 15 of 16 Report Date: 10/15/15

SSES MANAL Manual Name :

TRMI SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS Page 16 of 16 Report Date: 10/15/15 Page 16 of 16 Report Date: 10/15/15

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC 1.0 TABLE OF CONTENTS USE AND APPLICATION Page TRM / 1.0-1 Page TRM / 1.0-2 Page TRM / 1.0-3 2.0 3.0 PLANT PROGRAMS Page TRM / 2.0-1 Pages TRM / 2.0-2 and TRM / 2.0-3 Page TRM / 2.0-4 Page TRM / 2.0-5 Page TRM / 2.0-6 Page TRM / 2.0-7 Pages TRM / 2.0-8 and TRM / 2.0-9 Page TRM / 2.0-10 Page TRM / 2.0-11 Page TRM /2.0-12 Pages TRM / 2.0-13 and TRM / 2.0-14"\\,

Page TRM / 2.0-15

/,

\\

\\

-\\

O 3.1 3.2 3.3 APPLICABILITY

Y' Pages TRM / 3.0-1 and TR

/3.0-2 Page TRM /3.0-3

/..**,

Page TRM / 3.0-4

' '7/

REACTIVITY CONTROL SYSTEMS Page TRM / 3.i-1,

\\

Pages TRM /'3~.'1,2 anid Tl*M / 3.1-3 Pages 3.1-4 an*d,31-,5 \\

Page TRMI 3.-1-6,,

Page-TRM / 3.11*

Page TRM /'3.'1-8 Pages RM / 3.1-9 and TRM / 3.1-9a

/,P a~geTRM/'3.1-10

\\CORgE OPERATING LIMITS REPORT

',Page TRM / 3.2-1 Pages TRM / 3.2-2 through TRM / 3.2-54 INSTRUMENTATION Pages TRM / 3.3-1 through TRM / 3.3-3 Page TRM / 3.3-4 and TRM / 3.3-5 Page TRM / 3.3-6 04/2312015 10/04/2002 01/21/2014 10/04/2002 04/23/2015 0 1/28/2005 06/25/2002 01/21/2014 03/27/2008 05/15/2008 01/07/2011 02/02/2010 11/15/2004 03/27/2008 11/15/2004 11/15/2005 02/19/2015 03/15/2002 02/19/2015 10/31/2007 08/31/1998 08/31/1998 03/22/2006 04/07/2009 03/27/2008 02/18/1999 02/18181999 07/07/1999 04/21/2015 07/16/1 999 10/31/2007 03/10/2011 SUSQUEHANNA

- UNIT I TRM/LOES-1 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-1 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM / 3.3-7 Page TRM / 3.3-8 Page TRM / 3.3-9 Page TRM I 3.3-9a Page TRM / 3.3-10 Page TRMI/3.3-11 Page TRM / 3.3-11a Page TRM / 3.3-12 Page TRM / 3.3-13 Page TRM / 3.3-14 Page TRM I 3.3-15 Page TRM I 3.3-16 Page TRM / 3.3-17 Page TRM / 3.3-18 Pages TRM / 3.3-19 through TRM / 3.3-21 Page TRM / 3.3-22 Page TRM / 3.3-22a Pages TRM / 3.3-22b through TRM / 3.3-22d Page TRM / 3.3-23 Pages TRM / 3.3-24 and TRM / 3.3-25 Page TRM / 3.3-26 Page TRM / 3.3-27 Page TRM / 3.3-28 REACTOR COOLANT SYSTEM Page TRM / 3.4-1 Pages TRM / 3.4-2 through TRM / 3.4-5 Pages TRM / 3.4-6 through TRM / 3.4-8 Page TRM / 3.4-9 Page TRM / 3.4-10 Page TRM / 3.4-11 Page TRM / 3.4-12 Page TRM I 3.4-13 Pages TRM / 3.4-14 and TRM I 3.4-15 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 Pages TRM I 3.5-2 and TRM / 3.5-3 Pages TRM / 3.5-4 and TRM / 3.5-5 Pages 3.5-6 and 3.5-7 10/31/2007 08/31/1998 10/07/2015 06130/2010 10/31/2007 10/07/2015 10/07/2015 03/30/2001 01/07/2011 12/14/1 998 04/11/2014 01/07/2011 06/14/2002 10/31/2007 10/22/2003 03/27/2008 11/15/2004 03/22/2006 12/03/2004 05/16/2003 10/22/2003 02/19/2015 04/07/2009 03/31/2006 10/23/1998 04/01/2009 08/31/1998 10/31/2007 08/31/1998 03/27/2008 03/31/2006 04/25/2013 01/28/2005 08/31/1998 10/31/2007 08/31/1998 3.4 3.5 SUSQUEHANNA,- UNIT 1 TRM / LOES-2 SUSQEHANA-UITITRM LOS-2 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.6 3.7 CONTAINMENT Page 3.6-1 Pages TRM / 3.6-2 and TRM / 3.6-2a Page 3.6-3 Page TRM / 3.6-4 Page 3.6-5 Pages TRM / 3.6-6 through TRM I 3.6-8 PLANT SYSTEMS Pages 3.7-1 through 3.7-3 Page TRM / 3.7-4 Pages TRM / 3.7-5 Pages TRM / 3.7-6 through TRM I 3.7-8 Pages TRM / 3.7-9 and TRM / 3.7-10 Page TRM / 3.7-11 Page TRM / 3.7-12 Page TRM / 3.7.13 Page T.RM / 3.7-14 Pages TRM / 3.7-15 and TRM / 3.7-16 Page TRM / 3.7-17 Page TRM / 3.7-18 Page TRM / 3.7-19 Pages TRM / 3.7-20 through TRM / 3.7-22 Page TRM / 3.7-23 Page TRM / 3.7-24 Page TRM / 3.7-25 Page TRM / 3.7-26 Page TRM I 3.7-27 Pages TRM / 3.7-28 through TRM I 3.7-34a Page TRM / 3.7-35 Pages TRM / 3.7-36 and TRM / 3.7-37 Page TRM / 3.7-38 Page TRM / 3.7-39 Page TRM / 3.7-40 Page TRM / 3.7-41 Pages TRM I 3.7-41a through TRM / 3.7-41c Page TRM / 3.7-42 Page TRM / 3.7-43 Page TRM / 3.7-44 Pages TRM / 3.7-45 and TRM / 3.7-46 Page TRM / 3.7-47 08/31/1998 04/16/2014 08/31/1998 01/07/2002 08/31/1998 12/31/2002 08/31/1998 03/31/2006 04/07/2009 08/02/1999 04/07/2009 12/29/1999 08/02/1999 04/07/2009 08/09/2005 08/02/1999 04/07/2009 08/02/1999 04/07/2009 08/02/1999 04/07/2009 03/31/2006 08/02/1999 09/25/2012 11/24/2011 09/25/2012 03/31/2006 02/01/1999 02/19/2015 08/31/1998 03/31/2006 05/24/2012 05/24/2012 09/04/2008 08/31/1998 02/19/2015 10/05/2006 06/07/2007 SUSQUEHANNA

- UNIT I TRM / LOES-3 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-3 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECH NICAL REQUIREM ENTS MAN UAL)

Section Title Effective Date 3.8 Page TRM / 3.7-48 Page TRM / 3.7-49 Pages TRM / 3.7-49a and TRM / 3.7-49b Page TRM / 3.7-50 Page TRM I 3.7-51 Page TRM / 3.7-52 Page TRM / 3.7-53 Page TRM / 3.7-54 Pages TRM / 3.7-55 through TRM / 3.7-57 ELECTRICAL POWER Page TRM / 3.8-1 Page TRM / 3.8-2 Pages TRM / 3.8-3 and TRM /3.8-4 Pages TRM / 3.8-5 and TRM / 3.8-6 Page TRM / 3.8-7 Pages TRM / 3.8-8 through TRM I 3.8-10 Page TRM / 3.8-11 Page TRM / 3.8-12 Page TRM / 3.8-13 Page TRM / 3.8-14 Pages TRM / 3.8-15 through TRM ! 3.8-17 Page 3.8-18 Page TRM I 3.8-19 Page 3.8-20 Pages TRM / 3.8-21 and TRM / 3.8-22 Page TRM / 3.8-23 Pages TRM / 3.8-24 and TRM / 3.8-25 Page TRM / 3.8-26 Page TRM / 3.8-27 Pages TRM / 3.8-28 and TRM I 3.8-29 10/05/2006 06/07/2007 10/05/2006 01/21/2014 08/16/2006

  • 12103/2004 04/15/2003 07/29/1999 04/01/2009 04/02/2002 01/28/2005 03/25/2010 04/02/2002 10/31/2007 12/03/2004 09/03/2004 12/03/2004 02/19/2015 08/31/1998 04/02/2002 08/31/1998 04/02/2002 08/31/1998 06/06/1999 11/07/2013 11/30/2011 05/28/2009 11/29/2006 05/28/2009 08/31/1998 03/31/2006 08/31/1998 08/01/2006 03/22/2006 06/10/2010 03/27/2008 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 M ISCELLANEOUS Page TRM / 3.10-1 Pages TRM / 3.10-2 and TRM / 3.10-3 Page TRM / 3.10-4 Pages TRM / 3.10-5 and TRM / 3.10-6 Page TRM / 3.10-7 Page TRM / 3.10-8 SUSQUEHANNA

- UNIT I TRM / LOES-4 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-4 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.11 RADIOACTIVE EFFLUENTS Page TRM / 3.11-1 Pages TRM / 3.11-2 and TRM / 3.11-3, Page TRM / 3.11-4 Page TRM / 3.11-5 Page TRM / 3.11-6 Pages TRM / 3.11-7 and TRM I 3.11I-8 Pages TRM / 3.11-9 and TRM / 3.11-10 Pages TRM /3.11-11 and TRM /3.11-12 Page TRM / 3.11-13 Page TRM / 3.11-14 Pages 3.11-15 and 3.11-16 Page TRM /3.11-17 Page 3.11-18 Page TRM / 3.11-19 Pages TRM / 3.11-20 and TRM / 3.11-21 Page TRM / 3.11-22 Page TRM / 3.11-23 Page TRM / 3.11-24 Page TRM / 3.11-25 Pages TRM / 3.11-26 and TRM / 3.11-27 Page TRM / 3.11-28 Page TRM / 3.11-29 Pages TRM / 3.11.30 and TRM /3.11.31 Page TRM / 3.11.32 Page TRM / 3.11-33 Page TRM / 3.11-34 Page TRM / 3.11-35 Pages TRM / 3.11-36 through TRM / 3.11-39 Page TRM I 3.11-40 Pages TRM / 3.11-41 through TRM / 3.11-43 Page TRM / 3.1,1-44 Page TRM / 3.11-45 Page 3.11-46 Page TRM / 3.11 LOADS CONTROL PROGRAM Pages TRM / 3.12-1 through TRM / 3.12-3 Page TRM / 3.12-4 Page TRM / 3.12-5 03/31/2006 08/31/1998 03/31/2006 08/31/1998 03/31/2006 08/31/1998 10/09/2012 08/31/1998 02/19/2015 12/03/2004 09/01/1998 03/31/2006 08/31/1998 08/15/2005 03/31/2006 04/02/2002 11i/14/2006 06/18/2013 04/12/2007 01/21/2004 09/08/2009 12/03/2004 01/21/2004 04/23/2015 03/31/2006 08/31/1998 03/31/2006 11/30/2005 02/19/2015 08/31/1998 08/01/2006 03/31/2006 08/31/1998 03/31/2006 02/05/1999 03/14/2008 02/05/1999 08/31/1998 12/11/2008 08/31/1998 3.12 4.0 ADMINISTRATIVE CON~TROLS Pages 4.0-1 through 4.0-3 Page TRM / 4.0-4 Pages 4.0-5 through 4.0-8 SUSQUEHANNA - UNIT I TRM / LOES-5 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-5 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MAN UAL)

Section Title B 3.0 APPLICABILITY BASES Pages TRM / B 3.0-1 through TRM / B 3.0-3 Page TRM / B 3.0-4 Page TRM / B 3.0-4a and TRM I B 3.0-4b Page TRM / B 3.0-5 Page TRM / B] 3.0-6 Page TRM / B 3.0-7 Pages TRM / B 3.0-8 through TRM / B 3.0-10 Pages TRM / B 3.0-11 and TRM / B] 3.0-12 Pages TRM / B 3.0-13 through TRM / B] 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Page TRM / B 3.1-1 Page TRM / B 3.1-2 Page TRM / B 3.1-3 Page B] 3.1-4 Page TRM / B 3.1-5 Pages TRM / B] 3.1-6 and TRM / B 3.1-7 Page TRM / B 3.1-8 Effective Date 08/31/1998 02/19/2015 02/19/2015 02/19/2015 08/31/1998 04/12/2007 08/31/1998 03/15/2002 02/19/2015 B 3.1 B 3.2 B 3.3' CORE OPERATING LIMITS BASES Page B 3.2-1 INSTRUMENTATION BASES Page TRM / B] 3.3-1 Page TRM / B 3.3-2 Page TRM / B 3.3-2a Page TRM / B 3.3-3 Page TRM / B 3.3-3a Page TRM / B 3.3-4 Page TRM / B 3.3-5 Page TRM / B 3.3-6 Page TRM / B 3.3-7 Page TRM / B. 3.3-8 Page TRM / B 3.3-9 Pages TRM / B 3.3-10 through TRM / B 3.3-12 Page TRM /B 3.3-13 Page TRM / B 3.3-14 Page TRM / B 3.3-14a Page TRM / B 3.3-14b Pages TRM / B 3.3-15 and TRM / B 3.3-16 Page TRM / B 3.3-17 Pages TRM / B 3.3-17a through TRM / B 3.3-17c Page TRM / B] 3.3-17d 07/1 3/1 999 04/16/2014 10/31/2007 08/31/1998 11/15/2005 03/22/2006 02/18/1999 08/31/1998 01/21/2014 03/10/2011 10/31/2.007 12/11/2008 10/31/2007 06/30/2010 10/07/2015 06/30/2010 10/07/2015 06/30/2010 10/31/2007 01/07/2011 01/21/2014 06/25/2002 10/31/2007 10/31/2007 10/22/2003 03/22/2006 03/22/2006 03/27/2008 SUSQUEHANNA

- UNIT 1 TRM / LOES-6 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-6 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.4 B 3.5 B 3.6 B 3.7 Pages TRM / B 3.3-17e and TRM / B 3.3-17f Pages TRM / B 3.3-18 and TRM / B 3.3-19 Page TRM / B 3.3-20 Page TRM / B 3.3-2 1 Pages TRM / B 3.3-22 and TRM/IB 3.3-23 REACTOR COOLANT SYSTEM BASES Page B 3.4-1 Pages TRM / B 3.4-2 and TRM I B 3.4-3 Pages TRM / B 3.4-4 and TRM / B 3.4-4a Page TRM /B 3.4-5 Page B 3.4-6 Pages TRM / B 3.4-7 and TRM / B 3.4-8 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 Pages TRM / B 3.5-3 through TRM / B 3.5-5 CONTAINMENT BASES Page TRM / B 3.6-1 Page TRM / B 3.6-2 Page B 3.6-3 Page TRM / B 3.6-4 Page TRM / B 3.6-5 Page TRM / B 3.6-6 Pages TRM / B.3.6-7 through TRM / B 3.6-11 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Page TRM / B 3.7-3 Page TRM / B 3.7-3a Page TRM / B 3.7-4 Page TRM / B 3.7-5 Page TRM / B 3.7-6 Pages TRM / B 3.7-7 and TRM / B 3.7-7a Page TRM / B 3.7-8 Page TRM / B 3.7-9 Page TRM / B 3.7-10 Page TRM I B 3.7-I0a Page TRM / B 3.7-11 Page TRM / B 3.7-1 a Pages TRM / B 3.7-12 and TRM / B 3.7-13 Pages TRM / B 3.7-14 and TRM / B 3.7-14a 03/22/2006 08/03/2010 10/22/2003 05/16/2003 04/07/2009 08/31/1998 04/01/2009 10/31/2007 10/15/1999 08/31/1998 04/25/.2013 08/31/1998 10/31/2007 07/26/2001 02/01/1999 08/31/1998 03/27/2008 04/04/2007 12/03/2004 12/31/2002 08/31/1998 06/1 0/2010 12/27/2007 03/31/2006 08/02/1999 03/31/2006 08/02/1999 05/29/2013 04/11/2014 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 09/25/2012 SUSQUEHANNA - UNIT I TRM / LOES-7 EFFECTIVE DATE 10/07/2015 TRM / LOES-7

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM / B 3.7-14b Pages TRM / B 3.7-15 and TRM / B 3.7-16 Pages B 3.7-17 through B 3.7-20 Page TRM / B 3.7-21 Pages TRM / B 3.7-21a through TRM / B 3.7-21d Pages TRM / B 3.7-21e through TRM / B 3.7-21g Page TRM / B 3.7-22 and TRM / B 3.7-23 Page TRM / B 3.7-24 Page TRM / B 3.7-25 Pages TRM / B 3.7-26 through TRM / B 3.7-28 Pages TRM / B 3.7-29 and TRM / B 3.7-30 Page TRM / B 3.7-30a Page TRM / B 3.7-30b Page TRM / B 3.7-31 Page TRM / B 3.7-32 Page TRM / B 3.7-33 Page TRM / B 3.7-34 Page TRM / B 3.7-35 Pages TRM / B 3.7-36 through TRM / B 3.7-39 Page TRM / B 3.7-40 ELECTRICAL POWER BASES Page TRM / B 3.8-1 Page TRM 1 B 3.8-2 Page TRM / B 3.8-2a Page TRM / B 3.8-3 Page TRM / B 3.8-3a Page TRM / B 3.8-4 Page TRM / B 3.8-4a Page B 3.8-5 Pages TRM / B 3.8-6 through TRM / B 3.8-15 Page TRM / B 3.8-16 Page TRM / B 3.8-17 Pages TRM / B 3.8-17a and TRM / B 3.8-17b Pages TRM / B 3.8-18 through TRM / B 3.8-20 Pages TRM / B] 3.8-21 and TRM / B] 3.8-22 Page TRM / B] 3.8-23 Page TRM / B] 3.8-24 REFUELING OPERATIONS BASES Pages B 3.9-1 through B] 3.9-7 11/24/2011 02/01/1999 08/31/1998 05/29/2013 05/24/2012 05/29/2013 01/30/2008 10/05/2006 01/21/2014 10/05/2006 06/07/2007 10/05/2006 01/21/2014 11/30/2011 03/09/2001 04/15/2003 12/03/2004 07/05/2000 04101/2009 04/08/2010 04/02/2002 01/28/2005 03/01/20.10 04/02/2002 04/02/2002 09/03/2004 04/02/2002 08/31/1998 04/02/2002 11/07/2013 11/30/2011 11/30/2011 05/29/2013 05/28/2009 05/29/2013 05/28/2009 08/31/1998 B 3.8 B.3.9 SUSQUEHANNA

- UNIT I TRM / LOES-8 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-8 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.10 MISCELLANEOUS BASES Page B 3.10-1 Pages TRM / B 3.10-2 and TRM / B 3.10-3 Pages TRM / B 3.10-4 and TRM / B 3.10-5 Page TRM /B 3.10-6 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B 3.11-1 through B 3.11-9 Page TRM /B 3.11-10 Pages TRM/B 3.11-11 and TRM/B 3.11-11a Pages TRM/B 3.11-12 and TRM/B 3.11-13 Page TRM / B 3.11-14 Page TRM / B3.11-15 Pages B] 3.11-16 through B] 3.11-19 Page TRM/B[]3.11-20 Page TRM/ []3.11-20a Page TRM/B3.11-21 Pages TRM / B] 3.11-22 and TRM / B] 3.11-23 Pages TRM / B] 3.11-23a and TRM / B] 3.11-23b Pages TRM / B] 3.11-24 and TRM / B] 3.11-25 Pages B] 3.11-26 and B] 3.11-27 Page TRM/B[]3.11-28 Page TRM / B] 3.11-29 Pages TRM / B] 3.11-30 and TRM / B] 3.11-31 Page TRM / B] 3.11-32 Page TRM / [3.11-33 Pages B] 3.11-34 and B] 3.1 1-35 Page TRM / B] 3.11-36 B.3.12 LOADS CONTROL PROGRAM BASES Page TRM / B] 3.12-1 Page TRM / B] 3.12-2 Page TRM / B] 3.12-3 08/31/1998 03/22/2006 08/23/1999 03/27/2008 08/30/1998 02/01/1999 04/07/2000 02/01/1999 12/03/2004 02/01/1999 08/30/1998 04/02/2002 04/02/2002 05/13/2005 11/14/2006 06/18/2013 01/21/2004 08/30/1998 11/30/2005 02/19/2015 05/29/2013 08/30/1998 06/30/2010 08/30/1998 02/12/1999 09/19/2007 11/29/2010 02/05/1999 TRM1 text LOES I10/7/2015 SUSQUEHANNA-UNIT1 TRM / LOES-9 SUSQEHANA UNT I RM LOS-9EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 3.3 Instrumentation 3.3.4 TRM Post-Accident Monitoring Instrumentation TRO 3.3.4 The TRM post-accident monitoring instrumentation channels shown in Table 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.4-1 ACTIONS NiOTES.

1. Separate condition entry is allowed for each Function.
2. The provisions of TRO 3.0.6 are not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Enter the Condition referenced Immediately channel inoperable, in Table 3.3.4-1 for the channel.

B.

As required by Required B.1 Initiate the preplanned 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Action A.1 and referenced alternate method of monitoring in Table 3.3.4-1.

the appropriate parameter(s).

AND B.2 Restore the required channel 7 days / 30 days (*

to OPERABLE status.

C.

As required by Required C.1 Restore the required 30 days Action A.1 and referenced channel(s) to OPERABLE in Table 3.3.4-1 status.

D. As required by Required 0.1 Verify a minimum 14 of the Immediately Action A.1 and referenced in associated acoustic monitor Table 3.3.4-1 channels and 5 of the ADS AND SRV acoustic monitor channels are operable.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter (C) COMPLETION TIME for REQUIRED ACTION B.2 is extended from 7 to 30 days during construction activities associated with the replacement of SPING equipment with VERMS equipment.

SUSQUEHANNA - UNIT 1 TRM / 3.3-9 SUSQEHANA

- NITI TR

/ 33-9EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME OR D.2 Verify SRV tailpipe temperature indication and alarm are available for the tailpipe associated with the inoperable acoustic monitor.

OR D.3 Verify that the following alternate monitoring methods in TS Table 3.3.3.1-1 are OPERABLE:

Function 1 Function 2 Function 3 Function 10 AND D.4 Restore the required channel(s) to OPERABLE status.

Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter 30 days OR At next outage with containment entry, not to exceed the next refueling outage for in-accessible containment components.

SUSQUEHANNA-UNIT1 TRM / 3.3-9a SUSQEHANA UNT I RM 3.-9aEFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 TECHNICAL REQUIREMENT SURVEILLANCE NOTES---------------

1.

Refer to Table 3.3.4-1 to determine which TRSs apply for each Post Accident Monitoring Function.

2.

When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or an associated function is available.

SURVEILLANCE FREQUENCY TRS 3.3.4.1 Perform CHANNEL CHECK 31 days TRS 3.3.4.2 "Perform CHANNEL FuNcTIONAL TEST 92 days TRS 3.3.4.3 Perform a CHANNEL CALIBRATION. The Trip 24 months Setpoint shall be less than or equal to 0.25 of the full open nloise level.

TRS 3.3.4.4.

Perform CHANNEL CALIBRATION 24 months TRS 3.3.4.5 Perform CHANNEL CALIBRATION of the 92 days Primary Containment H2 and 02 Analyzers.

SUSQUEHANNA-UNIT1 TRM / 3.3-10 SUSQEHANA UNT 1 RM 3.-10EFFECTIVE DATE 10/31/2007

Rev. 8 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE

1. Suppression Chamber Air Temperature
2.

Main Steam Safety/Relief Valve Position Indicator (Acoustic Monitor)

3.

Reactor Building Vent Noble Gas Monitor

a. Mid Range(b)
b. High Range(b)
4.

Standby Gas Treatment System Vent Noble Gas Monitor 1,2 1,2 1/valve C

TRS 3.3.4.1 TRS 3.3.4.4 D

TRS 3.3.4.1 TRS 3.3.4.2 TRS 3.3.4.3 1,2, (a) 1,2, (a)

I 1

B TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4

a. Mid Range~b)
b. High Range(b) 1,2, (a) 1,2, (a) 1 I

B TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4

5.

Turbine Building Vent Noble Gas Monitor

a. Mid Range(b)
b. High Range(b) 1,2 1,2 1

1 B

TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4 (continued)

SUSQUEHANNA-UNIT1 TRM / 3.3-11 SUSQEHANA-UITITRM 3.-11EFFECTIVE DATE 10107/2015

Rev. 8 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 (continued)

TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE

6.

Standby Gas Treatment System Vent Stack Sampling System Flow

a.

Effluent System flow rate monitor(b) 1,2, (a)

IC TRS 3.3.4.1 TRS 3.3.4.4

b.

Sampler flow rate monitorcb) 1,2, (a)

IC TRS 3.3.4.1 TRS 3.3.4.4

7. Turbine Building Vent Stack Sampling System Flow
a.

Effluent System flow rate monitor(b) 1,2 1C TRS 3.3.4.1 TRS 3.3.4.4

b.

Sampler flow rate monitor(b)

TRS 3.3.4.1 1,2 1

C TRS 3.3.4.4

8. Containment H2 and 02 Analyzer(b) 1,2 2

C TRS 3.3.4.1 TRS 3.3.4.5 (a)

(b)

When moving irradiated fuel in the secondary containment.

TRO 3.0.4.c is applicable.

SUSQUEHANNA-UNIT 1 TRM / 3.3-1 la SUSQEHANA

-UNI I TM

/3.3-IaEFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The primary purpose of the TRM PAM instrumentation is to display plant variables that provide information required by the control room operators during accident situations. The OPERABILITY of the TRM PAM instrumentation ensures that the identified information is available on selected plant parameters to monitor and assess important variables following an accident. This capability is consistent with the recommendations of Regulatory Guide 1.97 Revision 2, "Instrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant Conditions During and following an Accident," NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations" and NEDO-33160-A Revision 1, "Regulatory Relaxation For The Post Accident SRV Position Indication System" (Reference 6). It should be noted that the Technical Specifications LCO 3.3.3.1 contains all Category 1, non-type A instruments and Regulatory Guide 1.97 Type A instrument (References 1 and 2). This TRO requires instruments outside of these criteria.

Table 3.3.4-1 identifies the following required Functions. Suppression Chamber Air Temperature provides a post accident indication of problems with the primary containment pressure suppression system. The Suppression Chamber Air Temperature loops are comprised of the following instruments for the purpose of this TRM. The recorders are the primary method of indication used by the operator during an accident; therefore, the PAM specification deals specifically with this portion of the instrument.

LOOP A LOOP B

  • TE-15703 TE-1 5725
  • TT-15703 TT-15725
  • TR-15795A TR-15795B Main Steam Safety/Relief Valve Position Indicators (Acoustic Monitors) provide indication when the valves are functioning. Alternate methods for monitoring SRV position include SRV Tailpipe Temperature and the following Functions from Technical Specification Table 3.3.3.1-1:

Suppression Chamber Water Level (Function 3)

Suppression Chamber Water Temperature (Function 10)

Reactor Vessel Water Level (Function 2)

Reactor Steam Dome Pressure (Function 1)

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.3-4 SUSQEHANA

-UNITI TM/B33-4EFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The required channels for REACTOR BUILDING VENT Noble Gas Monitor, (continued)

Standby Gas Treatment System Vent Noble Gas Monitor, and Turbine Building Vent Noble Gas Monitor provide information regarding the release of radioactive materials to allow for early indication of the need to initiate action necessary to protect the public and for an estimate of the magnitude of any impending threat. For the Noble Gas Monitors the only required channels are the mid range and high range.

The drywell and suppression chamber hydrogen and oxygen concentrations gas analyzers monitor hydrogen and oxygen concentration to detect combustible gas levels in primary containment. The analyzers are capable of determining hydrogen concentration in the range of 0 to 30% by volume and oxygen concentration in the range of 0 to 10% by volume, and each provide control room indication and output to a control room recorder. Each gas analyzer must be capable of sampling either the drywell or the suppression chamber. The recorders are the primary method of indication available for use by the operator during an accident, therefore the PAM Specification deals specifically with this portion of the instrument channel. The gas analyzer piping is provided with heat tracing to reduce the buildup of condensation in the system. H202 Analyzers can be considered OPERABLE for accident monitoring for up to 100 days with their heat tracing INOPERABLE.

ACTIONS The Actions are defined to ensure proper corrective measures are taken in response to the inoperable components.

During construction activities that replace existing SPING equipment with new VERMS equipment, the Vent Noble Gas Monitor for each release path is anticipated to be inoperable for longer than 7 days. Restoration completion time to return the affected channel to OPERABLE status to support construction activities is extended to 30 days. This condition is compensated for by the enhanced Preplanned Alternate Monitoring Plan per REQUIRED ACTION B.1.

(continued)

SUSQUEHANNA-UNIT1 TRM / B 3.3-5 SUSQEHANA

-UNI I RM

/B 33-5EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES ACTIONS (continued)

Action 0 requirements were determined by balancing the safety significance of the system with the impact of the actions on the operating unit. The loss of the acoustic monitors is not safety significant providing the diverse and redundant alternate methods of determining SRV position are available.

System components in the control room are restorable within 30 days without unit operation impact. Components located in containment require a unit shutdown to gain access to individual components. The sYstem channels shall be restored to operable condition at earliest opportunity.

Noble gas monitoring may be interrupted for up to 30 minutes to perform particulate filter/iodine cartridge changeout required by TRM Table 3.11.2-1 without entering the TRO ACTIONS.

Components of alternate SRV position systems may be taken inoperable for routine surveillances and periodic maintenance providing the appropriate LCO requirements are met during this action statement. Tailpipe temperature is the direct process monitoring, alternate method and is not covered by Technical Specification LCO's as are the other alternative methods.

TRS The Technical Requirement Surveillances (TRS) are modified by two Notes.

Note 1 states that the TRSs for each Post Accident Monitoring instrumentation Function are located in the SR column of Table 3.3.4-1.

Note 2 modifies the Surveillances to indicate that when a channel is placed in a inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or associated Function are available. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken.

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.3-6 SUSQEHANA

-UNI I RM

/B 33-6EFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS (continued)

The alternate means of monitoring the parameter or the associated function are:

Parameter Alternate Means/Associated Function Suppression Chamber Air Temperature Main Steam Safety/Relief Valve Position Indicator Containment H2 and 02 Analyzer One channel of Suppression Chamber Air Temperature Suppression Pool level Suppression Pool Temperature RPV level RPV pressure SRV Tailpipe Temperature One channel of Containment H2 and 02 The TRSs are defined to be performed at the specified Frequency to ensure that the TRM PAM Function is maintained OPERABLE.

TRS 3.3.4.1 Performance of the CHANNEL CHECK once every 31 days ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel against a similar parameter on other-channels. It is based on the assumption that (continued)

SUSQUEHANNA-UNiT1 TRM / B 3.3-7 SUSQEHANA

-UNI I RM

/B 33-7EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS TRS 3.3.4.1 (continued) instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.

Agreement criteria, which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit and does not necessarily indicate the channel is inoperable.

REFERENCES

1.

Regulatory Guide 1.97 Revision 2, "Instrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident."

2.

NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations."

3.

Technical Specification Amendment No. 100 to License No. NPF-22 for failed Unit 2 "5" acoustic monitor.

4.

Technical Specification Amendment No. 169 to License No. NPF-14 for failed Unit 1 "5" acoustic monitor.

5.

Proposed amendment No. 183 to License No. NPF-22 failed Unit 2 "J" acoustic monitor.

6.

NEDO-33160-A, Revision 1, "Regulatory Relaxation For The Post Accident SRV Position Indication System," dated October 2006.

7.

NRC letter, "Final Safety Evaluation For Boiling Water Reactor Owners' Group (BWROG) Topical Report (TR) NEDO-33160, Regulatory Relaxation For The Post Accident SRV [Safety Relief Valve] Position Indication System (TAC No. MC5446)," dated September 26, 2006.

SUSQUEHANNA-UNIT1 TRM / B 3.3-8 SUSQEHANA

-UNI I RM

/B 33-8EFFECTIVE DATE 06/30/2010

Oct.

15, 2015 Page 1

of 2

MANIJAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2015-41310 USER INFORMATION:

GERLACH*ROSEY N EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY N 10/15/2 015 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TRM2 TECHNICAL REQUIREMENTS MANUAL UNIT 2 REMOVE MANUAL TABLE OF CONTENTS DATE: 10/05/2015 ADD MANUAL TABLE OF CONTENTS DATE: 10/14/2015 CATEGORY:

DOCUMENTS TYPE: TRM2

Oct.

15, 2015 Page 2

of 2

ID:

TEXT 3.3.4 ADD:

REV:

8 REMOVE:

REV: 7 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT B3.3.4 ADD:

REV:

5 REMOVE:

REV:4 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT LOES ADD:

REV:

86 REMOVE:

REV:85 ANJY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INB0X.

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 Table Of Contents Issue Date:

10/14/2 015 Procedure Name TEXT LOES

Title:

LIST OF EF:

Rev Issue Date 86 10/14/2015 F'ECTIVE SECTIONS Change ID Change Number TEXT TOC

Title:

24 04/28/2015 TABLE OF CONTENTS TEXT 1.1 0

11/19/2002

Title:

use AND APPLICATION DEFINITIONS TEXT 2.1 1

02/04/2005

Title:

PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS TEXT 2.2 11 01/31/2014

Title:

PLANT PROGRAMS AND SETPOINTS INSTRUMENT TRIP SETPOINT TABLE TEXT 3.0

Title:

6 03/05/2015 APPLICABILITY TECHNICAL REQUIREMENT FOR OPERATION (TRO)

APPLICABILITY TEXT 3.1.1

-1 11/09/2007

Title:

REACTIVITY CONTROL SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT 3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3 4

05/14/2009

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT 3.2.1 11 04/28/2015

Title:

CORE OPERATING LIMITS CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 15 Report Date: 10/15/15 Page !

of 15 Report Date: 10/15/15

SSES MANTJAI~

Manual Name :

TRM2 ii*Manual

Title:

TECHNICAL REQUIREMENTS MANUJAL UNIT 2 TEXT 3,3.1 0

11/19/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUM4ENTATION TEXT 3,3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3,3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4

Title:

INSTRUMENTATION 8

10/14/2015 TRM POST-ACCIDENT MONITORING INSTRUMENTATION LDCN 4553 TEXT 3.3.5 0

11/19/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3,3.6 4

04/29/2014

Title:

INSTRUMENTATION TEN ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 1

11/09/2007

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3,3.8 1

10/22/2003

Title:

INSTRUMENTATION TEN RPS INSTRUMENTATION TEXT 3.3.9

Title:

INSTRUMENTATION TEXT 3.3.10

Title:

INSTRUMENTATION 3

05/14/2009 LPRM UPSCALE ALARM INSTRUMENTATION 1

12/14/2004 REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015

Title:

WATER MONITORING INSTRUMENTATION Page 2 of 15 Report Date: 10/15/15 Page !

of 15 Report Date: 10/15/15

SSES MANUJAI Manual Names TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.4.1

Title:

REACTOR TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.5.1 1

04/26/2006 COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM STRUCTURAL INTEGRITY 1*

11/09/2007 COOLANT SYSTEM REACTOR COOLANT SYSTEM (RCS) 2 05/14/2009 COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 1

04/26/2006 COOLANT SYSTEM REACTOR VESSEL MATERIALS 1

04/25/2013 RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION 1

02/04/2005

Title:

ECCS AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

ECCS AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/19/2002

Title:

ECCS AND RCIC LONG TERN NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/19/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/19/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page 3~

of 15 Report Date: 10/15/15 Page of 15 Report Date: 10/15/15

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.6.4 0

11/19/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1

Title:

PLANT TEXT 3.7.2 Title : PLANT TEXT 3.7.3,1 Title : PLANT TEXT 3.7.3.2 Title : PLANT

  • TEXT 3.7.3,3 Title : PLANT TEXT 3.7.3.4

Title:

PLANT TEXT 3.7.3.5

Title:

PLANT TEXT 3.7.3.6 Title : PLANT TEXT 3.7.3.7 Title : PLANT TEXT 3.7.3.8

Title:

PLANT TEXT 3.7.4

Title:

PLANT 0

11/19/2002 SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN 0

11/19/2002 SYSTEMS ULTIMATE HEAT SINK CURS) AND GROUND WATER LEVEL 2

04/16/2009 SYSTEMS FIRE SUPPRESSION WATER sUPPLY SYSTEM 3

04/16/2009 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 3

04/16/2009 SYSTEMS C02 SYSTEMS 2

04/16/2009 SYSTEMS HALON SYSTEMS 2

04/16/2009 SYSTEMS FIRE HOSE STATIONS 2

04/16/2009 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 1

04/26/2006 SYSTEMS FIRE RATED ASSEMBLIES 11 09/27/2012 SYSTEMS FIRE DETECTION INSTRUMENTATION 1

04/26/2006 SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 15 Report Date: 10/15/15 Page 4 of i_55 Report Date: 10/15/15

SSES MANUJAI

    • I Manual Name :

TRN2

... Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER 0FFGAS PRETREATMENT LOGARITHMIC RADIATION S

  • MONITORING INSTRUMENTATION
TEXT 3.7.8 9

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 1

08/28/2006

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 2

04/29/2014

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.1 1

10/02/2009

Title:

PLANT SYSTEMS TEXT 3.8.1 3

06/20/2012

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THEEMAJL OVERLOAD PROTECTION -

CONTINUOUS

£ TEXT 3.8.2.2 2

12/14/2004 WTitle: ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION AUTOMATIC Page !

of i_55 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRM2 i*

Manual

Title:

TECHNICAL REQUIREMENTS MANAL UNIT 2 TEXT 3.8,3 Title 2 ELECTRICAL TEXT 3.8,4 Title 2, ELECTRICAL TEXT 3.8,5 Title,, ELECTRICAL TEXT 3.8,6 Title 2 ELECTRICAL TEXT 3.8,7 2

06/20/2012 POWER DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 1

02/04/2005 POWER 24 VDC ELECTRICAL SUBSYSTEM 1

11/14/2013 POWER DEGRADED VOLTAGE PROTECTION 2

12/14/2006 POWER EMERGENCY SWITCHGEAR ROOM COOLING 2

10/22/2009 Title 2 BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9,1 0

11/19/2002 Title 2 REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/19/2002 Title 2 REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/19/2002 Title 2 REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006 Title 2 MISCELLANEOUS SEALED SOURCE CONTAMINATION TEXT 3.10.2 1

04/09/2007 Title 2 MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.11.1.1 1

04/26/2006 Title 2 RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION Page 6 of 15 Report Date: 10/15/15 Page h of 15 Report Date: 10/15/15

SSES MANTJI*

Manual Name :

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.1.2

Title:

RADIOACTIVE TEXT 3.11.1.3

Title:

RADIOACTIVE TEXT 3.11.1.4

Title:

RADIOACTIVE TEXT 3.11.1.5

Title:

RADIOACTIVE TEXT 3.11.2.1

Title:

RADIOACTIVE TEXT 3.11.2.2

Title:

RADIOACTIVE TEXT 3.11.2.3

Title:

RADIOAdTIVE FORM TEXT 3.11.2.4

Title:

RADIOACTIVE TEXT 3.11.2.5

Title:

RADIOACTIVE TEXT 3.11.2.6

Title:

RADIOACTIVE TEXT 3.11.3

Title:

RADIOACTIVE TEXT 3.11.4.1

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1

04/26/2006 LIQUID EFFLUENTS DOSE 1

04/26/2006 LIQUID WASTE TREATMENT SYSTEM 2

10/09/2012 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 3

03/05/2015 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 3

04/26/2006 DOSE RATE 1

04/26/2006 DOSE NOBLE GASES 1

04/26/2006 DOSE

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE 0

11/19/2002 GASEOUS RADWASTE TREATMENT SYSTEM 4

07/03/2013 VENTILATION EXHAUST TREATMENT SYSTEM 5

03/05/2015 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION 1

04/26/2006 TOTAL DOSE 4

03/05/2015 MONITORING PROGRAM Page 2 of 15 Report Date: 10/15/15 Page 7 of 15 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRM2

  • Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 LIGHT LOADS REQUIREMENTS TEXT 4.1

Title:

TEXT 4.2

Title:

TEXT 4.3

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

TEXT 4.7

Title:

0 09/27/2003 ADMINISTRATIVE CONTROLS ORGANIZATION ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

09/27/2003 CONTROLS REPORTABLE EVENT ACTION 0

09/27/2003 CONTROLS SAFETY LIMIT VIOLATION 1

12/18/2008 CONTROLS PROCEDURES & PROGRAMS 0

09/27/2003 CONTROLS REPORTING REQUIREMENTS 0

09/27/2003 CONTROLS RADIATION PROTECTION PROGRAM 0

09/27/2003 CONTROLS TRAINING Page 8 of 15 Report Date: 10/15/15 Page 8 of 15 Report Date: 10/15/15

SSES M.ANUJAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.0 6

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION CTRO)

APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEM BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT B3.1.3 3

04/10/2007

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION A.

AND CHECK VALVE TEXT B3.2.1

Title:

CORE OPERATING L TEXT B3.3.1

Title:

INSTRUMENTATION TEXT B3.3.2

Title:

INSTRUMENTATION TEXT B3.3.3

Title:

INSTRUMENTATION TEXT B3.3.4

Title:

INSTRUMENTATION TEXT B3.3.5

Title:

INSTRUMENTATION TEXT B3.3.6

Title:

INSTRUMENTATION

,IMITS 0

11/19/2002 BASES CORE OPERATING LIMITS REPORT (COLR) 1 01/31/2014 BASES RADIATION MONITORING INSTRUM]ENTATION 2

03/31/2011 BASES SEISMIC MONITORING INSTRUMENTATION 2

11/09/2007 BASES METEOROLOGICAL MONITORING INSTRUMENTATION-5 10/14/2015 BASES TEN POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION LDCN 2

11/09/2007 BASES THIS PAGE INTENTIONALLY LEFT BLANK 5

01/31/2014 BASES TEN ISOLATION ACTUATION INSTRUMENTATION 4553 Page ~

of 15 Report Date: 10/15/15 Page 9 of i_55 Report Date: 10/15/15

SSES MANUJAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MAMATJAL UNIT 2 TEXT B3.3.7

Title:

INSTRUMENTATION 1

11/09/2007 BASES MAIN TURBINE 0VERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22/2003

Title:

INSTRUMENTATION BASES TRM RPS INSTRUMENTATION TEXT B3.3.9

Title:

INSTRUMENTATION 3

05/.14/2009 BASES. LPRM UPSCALE ALARM INSTRUMENTATION TEXT B3.3.10 3

02/22/2012

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS TEXT B3.3.11 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.3.12 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2

Title:

REACTOR COOLANT TEXT B3.4.3

Title:

REACTOR COOLANT TEXT B3.4.4

Title:

REACTOR COOLANT TEXT B3.4.5

Title:

REACTOR COOLANT TEXT B3.4.6 1

04/16/2009 SYSTEM BASES STRUCTURAL INTEGRITY 1

11/09/2007 SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR 0

11/19/2002 SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 0

11/19/2002 SYSTEM BASESREACTOR VESSEL MATERIALS 1

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION Page i~.

of 15 Report Date: 10/15/15 Page i0 of 15 Report Date: 10/15/15

SSES MANUAL q

Manual Name :

TRM2 SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.5.1

Title:

EGGS AND RCIG 0

11/19/2002 BASES ADS MANUAL INHIBIT TEXT B3.5.2 1

11/09/2007

Title:

EGGS AND RCIG BASES EGGS AND RGIG SYSTEM MONITORING INSTRUMENTATION TEXT B3.5.3 1

11/09/2007

Title:

EGGS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION GRAMBER-TO-DRYWELL VACUUJMBREAKER POSITION INDICATION TEXT B3.6.3 1

04/19/2007

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1

Title:

PLANT TEXT B3.7.2

Title:

PLANT TEXT B3.7.3.1

Title:

PLANT TEXT B3.7.3.2

Title:

PLANT TEXT B3.7.3.3

Title:

PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0

11/19/2002 EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN) 0 11/19/2002 ULTIMATE HEAT SINK (URS)

GROUND WATER LEVEL 3

06/15/2010 FIRE SUPPRESSION WATER SUPPLY SYSTEM 2

04/26/2006 SPRAY AND SPRINKLER SYSTEMS 0

11/19/2002 C02 SYSTEMS Page 12.

of 15 Report Date: 10/15/15 Page i!l of 15 Report Date: 10/15/15

SSES MANUAL Manual Name:

TRM2 SManual Title-TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.3.4

Title:

- PLANT TEXT B3.7.3.5 Title : PLANT TEXT B3.7.3.6

Title:

PLANT TEXT B3.7.3.7 Title : PLANT TEXT B3.7.3.8

Title:

PLANT TEXT B3.7.4 Title : PLANT TEXT B3.7.5.1 Title : PLANT TEXT B3.7.5.2 Title : PLANT TEXT B3.7.5.3 Title : PLANT TEXT B3.7.6 Title : PLANT 2

04/29/2014 HALON SYSTEMS SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 1

04/26/2006 FIRE HOSE STATIONS 1

04/26/2006 YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 FIRE RATED ASSEMBLIES 3

09/27/2012 FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SOLID RADWASTE SYSTEM 0

11/19/2002 MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/19/2002 MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002 LIQUID HOLDUP TANKS 4

06/04/2013 ESSW PUMPHOUSE VENTILATION 2

01/31/2008 TEXT B3.7.7

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFOAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION TEXT B3.7.8 4

Title:

PLANT SYSTEMS BASES SNUBBERS 01/31/2 014 Page 12 of 15 Report Date: 10/15/15 Page 1/2 of i_55 Report Date: 10/15/15

SSES MANUJAI a

i Manual Name:

TRJA2 W-Manual

Title:

TECHNJICAL REQUIREMENTS MAMAL UNIT 2 TEXT B3.7.9 2

12/08/2011

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE IDVAC TEXT B3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.7.11

Title:

STRUCTURAL TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL TEXT B3.8.5

Title:

ELECTRICAL TEXT B3.8.6

Title:

ELECTRICAL TEXT B3.8.7 2

04/14/2010 INTEGRITY 2

03/10/2010 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 1

09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

PROTECTION -

0 11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE 0

11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 1

11/14/2013 POWER BASES DEGRADED VOLTAGE PROTECTION 3

06/20/2012 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 2

06/04/2013 ACTIVITIES

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME Page 23.

of 15 Report Date: 10/15/15 Page 13 of 15 Report Date: 10/15/15

SSES MANTJAL Manual Name:

TRM2 SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COJYUIUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

Title:

MISCELLANEOUS BASES SEALED 11/19 /2 002 SOURCE CONTAMINATION TEXT B3.10.2 1

04/10/2007

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.11i.1.

Title:

RADIOACTIVE TEXT B3.11.1.2

Title:

RADIOACTIVE TEXT B3.11.1.3

Title:

RADIOACTIVE TEXT B3.11.1.4

Title:

RADIOACTIVE 0

11/19/2002 EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION 0

11/19/2002 EFFLUENTS BASES LIQUID EFFLUENTS DOSE 0

11/19/2002 EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM 0

11/19/2002 EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5 U

Title:

RADIOACTIVE EFFLUENTS BASES 11/19/2 002 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT B3.11.2.1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2

Title:

RADIOACTIVE EFFLUENTS 0

11/19/2002 BASES DOSE NOBLE GASES Page 14 of 15 Report Date: 10/15/15 Page 1__{4 of 15 Report Date: 10/15/15

SSES MAi*TA Q

Manual Name:*

TRM2 W:i Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM 0

BASES 11/19/2002 DOSE

IODINE, TRITIUM, AND RADIONUCLIDES IN TEXT B3.11.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT 33.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.12.1

Title:

LOADS CONTROL PROGRAM TEXT B3.12.2

Title:

LOADS CONTROL PROGRAM TEXT B3.12.3

Title:

LOADS CONTROL PROGRAM 5

.07/03/2013 BASES VENTILATION EXHAUST 1

01/27/2004 BASES RADIOACTIVE GASEOUS 0

11/19/2002 BASES TOTAL DOSE 5

03/05/2015 BASES MONITORING PROGRAM 0

11/19/2002 BASES LADUSE CENSUS TREATMENT SYSTEM EFFLUENT MONITORING 0

BASES 11/19/2 002 INTERLABORATORY COMPARISON PROGRAM 1

10/04/2007 BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL 1

12/03/2010 BASES HEAVY LOADS REQUIREMENTS 0

11/19/2002 BASES LIGHT LOADS REQUIREMENTS Page i~.

of 15 Report Date: 10/15/15 Page 15 of i__55 Report Date: 10/15/15

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LUST OF EFFEC TIVYE SECTIONS (TIECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC 1.0 2.0 3.0 TABLE OF CONTENTS USE AND APPLICATION Page TRM / 1.0-1 Page TRM 1 1.0-2 Page TRM 1/1.0-3 04/23/2015 08/31/1998 10/04/2002 08/31/1998 PL.ANT PROGRAMS Page 2.0-1 Pages TRM 1 2.0-2 and TRM 2.0-3 Page TRM I 2.0-4 Page TRM / 2.0-5 Page TRM / 2.0-6 Page TRM 1 2.0-7 Pages TRM /2.0-8 and TRM / 2.0-9 Page TRM / 2.0-10 Page TRM / 2.0-11 Page TRM / 2.0-12 Pages TRM /2.0-13 and TRM / 2.0-14 Page TRM /2.0-15 APPLICABILITY Pages TRM / 3.0-1 and TRM, / 3.0-2 Page TRM /13.0-3, Page TRM I 3.0-4 REACTIVITY cONTROL sYSTEMS Page TRMI /3.i1-1 Pages TRM /]3.1-2 through TRM / 3.1-5

.Page-TRM / 3.1-6 Page-TRM 1 31-7 Page TRM / 3.1-8 S-Pages TRM / 3.1-9 and TRM 1 3.1-9a "Page TRM /3.1-10

  • CORE OPERATING.LIMITS :REPORT

...Page TRM /3.2-1 Pages TRM / 3.2-2 through TRM /3.2-54 INSTRUMENTATION Pages TRM 1 3.3-1 through TRM / 3.3-3 Pages TRM / 3.3-4 and TRM /13.3-5 Page TRM / 3.3-6 Page TRM 3.3-7 Page 3.3-8 08/31 /1998

.... 01/28/2005 06/25/2002 01./2.1/2014

  • ,04,/15/2009 05/15/2008 01/07/2011 02/02/2010 11/15/2004 04/15/2009 11/15/2004 11/15/2005 3.1 02/19/2015 03/15/2002 02/19/2015 10/31/2007 08/31/1995 03/27/2007 04/15/2009 03/27/2007 02/18/1999 02/18/1999 08/31/1998 04/21/2015 07/16/1999 10/31/2007 03/10/2011 10/31/2007 08/31/1998 3.2 3.3 SUSQUEHANNA - UNIT 2 TRM 1,/OES-1 SUSQEHANA UNT 2 RM LOS-1EFFECTIVE DATE 10/07/2015

I7 ii O

I SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Page TRM / 3.3-9 Page T]RM / 3.3-9a Page TRM /3.3-10 Page TRM / 3.3-11 Page TRM / 3.3-lia Page "TRM / 3.3-12 Page TRM / 3.3-13 Page TRM 1 3.3-14 Page TRM / 3.3-15 Page TRM / 3.3-16 Page TRM / 3.3-17 Page TRM I 3.3-18 Pages TRM 1 3.3-19 and TRM 13.3-20 Page TRM / 3.3-21 Page TRM / 3.3-21a Pages T]RM /3.3-21b through TRM I 3.3-21d Page TRM /3.3-22 Pages TRM / 3.3-23 and TRM / 3.3-24 Page TRM /3.3-25 Page TRM /3.3-26 Page TRM / 3.3-27 3.4 REACTOR COOLANT SYSTEM Page TRM / 3.4-1 Pages 3.4-2 through 3.4-5 Pages TRM / 3.4-6 through TRM t 3.4-8 Page 3.4-9 Page 3.4-10 Page 3.4-11 Page TRM / 3.4-12 Page TRM / 3.4-13 Page TRM / 3.4-14 3.5 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 Pages 3.5-2 and 3.5-3 Page TRM / 3.5-4 Pages 3.5-5 through 3.5-7 3.6 CONTAINMENT Pages 3.6-1 and 3.6-2 Pages TRM,/3.6-3 and TRM / 3.6-3a Page 3.6-4 Page TRM / 3.6-5 Page 3.6-6 Pages TRM / 3.6-7 through TRM I 3.8-9 Effective Date 10/0"7/2015 06/3012010 10/3112007 10/07/2015 101071/2015 03/30/2001 01,/0712011 12/14/1998 04111/2014 01/07/2011 06114/2002 10/311/2007 10/22/2003 04115/2009 11,/15/2004 03/27,/2007 12/03/2004 05/16/2003 10,/22/2003 02119/2015 "04t07,/2009 03/31/2006 10/23/1998 04/01/2009 08/31,/1998 10/31/2007 08/31/1998 04117/2009 03/31/12006 04/25/2013 01/28/2.005 08/31/1998 10/31/2007 08/31/1998 08/31/1998 04/16/2014 08/31/1998 01/07/2002 08/31/1998 12/31/2002 SUSQUEHANNA

- UNIT 2 TRM / LOES-2 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM / LEES-2 EFFECTIVE DATE 10107/2015

SUSQUEHANNA STEAM ELECTRIC STATION -Rev.

86 UIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.7 O_*,.

PLANT SYSTEMS Pages TRM I 3.7-1 and TRM I 3.7-2, Page 3.7--3 Page TRM 1 3.7-4 Page TRM 1 3.7-5 Pages TRM 1]3.7-6 through TRM 1 3.7-8 Pages TRM 1 3.7-9 and TRM / 3.7-10 Page TRM 1 3.7-i11 Page TRM 1 3.7-12 Page TRM !/3.7-13 Page TRM 1 3.7-14 Pages TRM / 3.7-15 and TRM / 3.7-16 Page TRM 1 3.7-17 Page TRM 1 3.7-18 Page TRM 1 3.7-19 Pages TRM 1 3.7-20 through TRM / 3.7-22 Page TRM / 3.7-23 Page TRM 13.7-24 Page TRM / 3.7-25 Page TRM /3.7-26 Page TRM 13.7-27 Pages TRM 1 3.7-28 through TRM /3.7-32a Page TRM / 3.7-33 Page TRM /3.7-34 Pages TRM 1 3.7-35 and TRM / 3.7-36 Page TRM 1 3.7-37 Page TRM /3.7-3.8 Page TRM / 3.7-39 Page TRM !/3.7-40 Pages TRM 1 3.7-40a through TRM / 3.7-40c Page TRM / 3.7-41 Page TRM / 3.7-42 Pages TRM / 3.7-43 Pages TRM 1 3.7-44 and TRM / 3.7-45 Page TRM /3.7-46 Page TRM / 3.7-47 Page TRM / 3.7-48 Page TRM ! 3.7-49 Page TRM / 3.7-50 Page TRM / 3.7-51 Page TRM / 3.7-52 Page TRM / 3.7-53 Page TRM /3.7-54 Page TRM /3.7-55 Page TRM /3.7-56 0712911999 08/31/i1998 03/31/2006 04/07/2009 08102/1999 04/07/2009 01/2112.000 08/0211999 04/07/2009 08/09/2005 08/0211999 04/07/2009 08/02/1 999 04/07/2009 08/02/1999 04/07/2009 03/31/2006 08/02/1999 09/25/2012 11/24/2011 09/25/2012 09/25/2012 03/31/2006 02/01/1999 02/19/2015 08/31/1998 03/31/2006 05/24/2012 05/24/2012 09104/2008 08/31/1998 02/19/2015 10/05/2006 06/07/2007 09/05/2012 06/07/2007 03/09/2001 08/16/2006 12/03/2004 04/15/2003 07/29/1999 04/01/2009 09/25/2009 04/01/2009 SUSQUEHANNA - UNIT 2 TRM /LOES-3 EFFECTiVE DATE 10/07/2015 SUSQUEHANNA - UNIT 2 TRM/LOES-3 EFFECTlVE DATE 10/07/2015

SUSQUEH-ANNA STEAM ELECTRIC STATION Rev. 86" LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.8 ELECTRICAL POWER Page TRM /3.8-1 Page TRM / 3.8-2 Pages TRM / 3.8-3 and TRM I 3.8-4 Pages TRM / 3.8-5 and TR 1 3.8-6 Pages TR

/ 3.8-7 through TRM / 3.8-10 Page TRM 1 3.,8-11 Page TRMJ]3..8-12 Page TRM /3.8-13 Page TRM 1 3.8-14 Page TRM / 3.8-15 Pages TRM /3.8-16 and TRM 1 3.8-17 Page 3.8-18 Page TRM / 3.8-19 Page TRM 1 3.8-20 Pages TRM / 3.8-21 and TRM /3.8-22 Page TRM / 3.8-23 Page TRM / 3.8-24 Page TRM 1 3.8-25 Pages TRM / 3.8-25a and TRM I 3.8-25b Page TRM / 3.8-26 Page TRM / 3.8-27 Page TRM 1 3.8-28 Page TRM 1 3.8-29 04/02/,2002 0112812005 06/11/2012 04/0212002 10/31/2007 0910312004 1210312004 06/1212012 0'8131/1998 01/28/2005 04/02/2002 021,0111999 04./0212.002 02101/'1999 06106/1999 1110,7/2013 11/30/2,011 06/11/2012 I1/1301201.1 05/28/2009 11/29/2006 05/28/2009 10120/2009 08/3111998 03/31/2006 08/30/1998 03/27/2 007 06/10/2010 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 3.11 MISCELLANEOUS Page TRM / 3.10-1 Pages 3.10-2 through 3.1.0-4 Pages TRM / 3.10-5 and TRM /3.10-6 Page TRM / 3.10-7 RADIOACTIVE EFFLUENTS Page TRM 1 3.11-1 Pages 3.11-2 through 3.11-3 Page TRM / 3.11-4 Page 3.11-5 Page TRM / 3.11-5 Pages 3.11-7 and TRM /3.11-8 Pages TRM / 3.11-9 and TRM / 3.11-10 Pages TRM / 3.11-11 and TRM / 3.11-12 103131/2006 08/31/1 998 03/31/2005 08/31/1998 03/31/2006 08/31/1998 10/09/2012 08/31/1998 SUSQUEHANNA-UNIT 2 TRM / LOES-4 EFFECTIVE DATE 10/07/2015 SUSQU*5*NNA - 'UNIT 2 TRM ! LOES-4 EFFE'CTI* DATE 10t07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 UIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM 1 3.11-13 Page TRM I 3.11-14 Pages 3.11-15 and 3.11-16 Page TRM 1 3.11-17 Page 3.11-18 Page TRM/]3.11-19 Pages TRM 1 3.11-20 and TRM / 3.11-21 Page TRM 1 3.1-22 Page TRM ]13.11-23 Page TRM 1 3.11-24 Page T']RM 13.11-25 Pages TRM 1 3.11-26 and T'IRM 1 3.11-27 Page TRM 1 3.11-,28 Page TRM / 3.11-29 Pages TRM 3.11--30 and TRM 1 3.11-31 Page TRM 1 3.11-32 Page TRM / 3.11-33 Page 3.11-34 Page TRW / 3.11-35 Pages TRM ] 3.11-36 through TRM 1 3.11-39 Page T]RM / 3.11-40 Pages TRM 1 3.11-41 through TRM 1 3.11-44 Page TRM 1 3.11-45 Page 3.11-46 Page TRW / 3.11-47 LOADS CONTROL PROGRAM Pages TRM 1 3.12-1 through TRM / 3.12-3 Page TRM 1 3.12-4 Page TRM / 3.12-5 ADMiNISTRAT]IVE CONTROLS Pages TRM / 4.0-1 through TRM / 4.0-3 Page TRM 1]4.0-4 Pages TRM / 4.0-5 through TRM / 4.0-8

_02/1 912015 1210312004 09/01/1998 03131/2006 08/3111998 08115/2,005 03/31/20106

'04/02/2002 11/14/2006 06/18/2,013 04/1212007 01/21/2004 09/08/'2009 1.2/03/2004 01121/2004 02/19/2015 03/31/2006 08/31/1998 03/31/2006 11/30/2005 02/19/2015

'08/31/1998 03/31/2006 08/31/1998 03/31/2006 02/05/1999 03/14/2008 02/05/1999 08131/1998 12/11/2008 08/.31/1998 3.12 4.0 SUSQUEHANNA - UNiT 2 TRM / 'LOES-5 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - 'UNlT 2 TRM / LOES-5 EFFECTIVE DATE 10107t2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LIST OF EFFECTIVE SECiTIONS (TECHNICAL REQUIREMENTS MANUAL)

I.

Section Tlitle 8 3.0 APPUCAB~iLITY BASES Pages TRM 1 B 3.0-1 through TRM I B 3.0-3 Page TRM I B 3.0-4 Pages TRM I B 3.0-4a and TRM 1 B 3.O-4b Page -TRM 1 B 3.0-5 Pages T]RM / B 3.0-6 and TRM I B 3.0-7 Pages TRM I B 3.0-8 through TRM I1B 3.0-10 Pages TRM / B 3.0-11 and TRM / B 3.0-12 Pages TRM I B 3.0-13 through TRM I B 3.0-15 B 3.1 REACTIV*IIY CONTROL SYSTEMS BASES Page TRM I B 3.1-1 Page TRM I B 3.1-2 Page TRM /B 3.1-3 Page B 3.1-4 Pages TRM 1 B 3.1-5 through TRM /8B3.1-7 Page TRM I B 3.1-8 B 3.2 CORE OPERATING UMITS BASES Page B 3.2-1 B 3.3 INSTRUMENTATION BASES Page TRM I B 3.3-1 Page TRM I B 3.3-2 Page TRM I B-3.3-2a Pages T RM 1 B 3.3-3 and TRM / B 3.3-3a Page TRM /8B 3.3-4 Pages TRM / B 3.3-5 through TRM / B 3.3-7 Page TRM 1 B 3.3-8 Page TRM 18B3.3-9 Page TRM /8B3.3-10 Page TRM 18B3.3-11 Pages TRM /8 3.3-12 and TRM /8B3.3-13 Page TRM /8B3.3-14 Page TRM ! B 3.3-14a Page TRM /8 3.3-14b Pages TRM / B 3.3-15 through TRM ! B 3.3-17 Pages TRM I B 3.3-18 and TRM /8B3.3-19 Pages TRM I B 3.3-19a and TRM /8B 3.3-19Sb Page TRM /8B3.3-19Sc Effective Date 08/31/1998 02119/2015 02/19/2015 02/1912015

'06/1 2/2012 08/31/1998 03/1512002 02/19/2015 07/13/1999 0411612014 10/31/2007 08/31/1598 03/27/2007 02/1 811999 05/31]1 998 01/21/2014 03/10/2011 10/31/2007 10/31/2007 06/30/2010 10/07/2015 06/30/2010 10/31/2007 01/07/2011 02/21/2014 01/07./2,011 06/25/2002 10/31/2007 06/14/2002 10/22/2003 03/27/2007 03/27/2007 04/17/2009 SUSQUEHANNA - UNIT 2 TRM I LOES-6 SUSQEHANA-UNI 2 RM LOS-6EFFECTIVE DATE 10/07/2,01!5

SUSQUEHANNA STEAM ELECTRIC STATiON Rev. 86 LIST OFEFFECTIVSECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title B 3.4 B 3.5 Pages TRM 1 B 3.3-19d and TRM I B 3.3-19e Page TRM I B 3.3-2,0 Page TRM I B 3.3-21 Page TR I B 3.3-22 Page TRM I B 3.3-23 Pages TRM I B 3.3-24 and TRM I B 3.3-25 REACTOR COOLANT SYSTEM BASES Page TRM I B 3.4-1 Pages TRM 1 B 3.4-2 and TRM 1 B3.4-3 Pages TRM / B 3.4-4 and T3RM I B 3.4-4a Page TRM I B 3.4-5 Page B 3.4-6 Page TRM / B 3.4-7 ECCS AND RC1C BASES Pages B 3.5-1 and B 3.5-2 Pages TRM ] B 3.5-3 and TR I B 3.5-3a Page B 3.5-4 Page TRM / B 3.5-5 CONTAINMENT BASES Page TRM I B 3.6-1 Page TRM I B 3.6-2 Page B 3.6-3 Page TRM I B 3.8-4 Page TRM I B 3.6-5 Page TRM I B 3.6-6 Pages TRM /' B 3.6-7 through TRM / B 3.8-11 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Page TRM I B 3.7-3 Page TRM I B 3.7-3a Page TRM I B 3.7-4 Page TRM I B 3.7-5 Pages TRM / B 3.7-6 and TRM I B 3.7-6a Pages T'RM I B 3.7-7 and TRM I B 3.7-7a Page TRM / 'B 3,.7-8 Page TRM / B 3.7-9 Page TRM I B 3.7-10 8 3.6 Effective Date 03127/2007.

0211,612012 08103/2010 10/22/2003 05/1612003 04/07/2009 0813111998 0410112009 1013112007 10/15/1999 0813111998 04/25/2013 08/31/11998 10/31/2007 083/3111998 10/3112007 07/26./2001 02101/1999 08/31/]1998 0312912007 04/04/2007 12/03/2004 12/31/2002 08/3111998 06/1012010 12/27/2007 03/31/2006 08/0211999 03/31/2006 08/02/1 999 08/02/1.999.

04/11/2014 08/02/1999 B 3.7 SUSQUEHANNA -UNIT 2 TRM ] LOES-7 SUSQEHANA UNT 2 RM LOS-7EFFECTIVE DATE 10/07/2015

SUSQUEH-ANNA STEAM ELECTRIC STATION Re i*..

UST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL).=v. 86 Section Title Effective Date Pages TRM I B 3.7-10Ca through TRM I B 3.7-1 Ia Pages TRM I B 3.7-12 and TRM I B 3.7-13 Pages TRM I B 3.7-14 through TRM I B 3.7-14b Pages TRM I B 3.7-15 and TRM I B 3.7-16 Pages B 3.7-17 through B 3.7-2,0 Page TRM I B 3.7-21 Pages TRM I B 3.7-21a through TRM I B 3.7-21d Pages TRM I B 3.7-21e through TRM I B 3.7-21g Pages TRM I B 3.7-22 and TRM ! B 3.7-23 Page TRIM! B 3.7-24 Page TRM I B 3.7-25 Pages TRM I B 3.7-26 through TRM I B 3.7-29 Page TRM I B 3.7-30 Page TRM / B 3.7-30a Page TRM I B 3.7-30b Page TRM I B 3.7-31 Page TRM I B 3.7-32 Page TRM I B 3.7-33 Page TRM I B 3.7-34 Page TRM / B 3.7-35 Pages TRM I B 3.7-36 and TRM I B 3.7-37 Page TRM I B 3.7-38 Page TRM I B 3.7-39 Page TRM I B 3.7-40 ELECTRICAL POWER BASES Page TRM I B 3.8-1 Pages TRM I B 3.8-2 Page TRM I B 3.8-2a Pages TRM I B 3.8-3 and TRM I B 3.8-3a Page TRM I B 3.8-4 Page TRM I B 3.8-4a Page TRM I B 3.8-5 Pages TRM l B 3.8-6 through TRM I B 3.8-15 Page TRM 18B3.8-16 Page TRM / B 3.8-17 Page TRM I B 3.8-17a Page TRM / B 3.8-17b Pages TRM 18B3.8-18 through TRM I B 3.8-20 Pages TRM /8B3.8-21 and TRM / B 3.8-22 Page TRM I B 3.8-23 Page TRM 18B3.8-24 03/3112006 08/02/1999 0912512012 0210111999 08/3111998 05/29/2013 051.2412012 05/29/2013 01J30]2008 10105/2006 01/2112014 10/0512006 06/07/2007 10/05/2006 01121']2014 11/30/2011 03/09/2001 04/15/2003 12/0312004 07/]05/2.000 04/0112009 09/25/2009 04/01/2009 04/08/2010 04/02/2002 01/28/2005 03/01/2010 04/02/2002 09/03/2004 04/0212002 08/31/1998 04/02/2002 11/07/2013 11/30/2011 06111/2012 11/30/2011 05/29/2013 05/28/2009 05/29/2013

,05/2812009 B 3.8 e

SUSQUEHANNA - UNIT 2 TRM / LQES-8 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM / LOES-8 EFFECTIVE DATE 10f07/2015

J.

I 9 "

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LISTOF EFFECTIV E SECTIONS (]TECHNIlCAL REQUIREMENTS MANUAL)

Section Title Effective Date B.3.9 REFUELING OPERATIONS BASES Pages B 3.9-i and B 3.9-2 Pages B 3.9-3 through B 3.9-7 B 3.10 MISCELLANEOUS BASES Page B 3.10-i Pages TRM I B 3.10-2 and TiRM I B 3.10-3 Pages TRM I B 3.10-4 and TRM I B 3.10-5 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B 3.11-1 through B 3.11-9 Page TRM I B 3.11-10 Pages T-IRM / B 3.1 1-11 and TRM / B 3.1 1-11a Pages TRM I B 3.11-12 and TRMI B 3.11-13 Page TRM I B 3.11-14 Page TRM 18B3.11-15 Pages B 3.11-16 through B 3.11-19 Pages TRM I B 3.11-20 and TRM I B 3.1 1-20a Page TRM / B 3.11-21 Pages TRM /B 3.11-'22 and TRM I B 3.11-23 Pages TRM /B 3.1 1-23a and TRM I B 3.1 1-23b Pages TRM /8B3.11-24 and TRMI]B 3.11-25 Pages B 3.11-26 through B 3.11-27 Page TRM / B 3.1 1-28 Page TRM I B 3.11-29 Pages TRM / B 3.11-30 and TRM l B 3.11-31 Page TRM 18B3.11-32 Page TRM /8B3.11-33 Pages TRM / B 3.11-34 and TRM I B 3.11-35 Page TRM 18B3.11-36 8.3.12 LOADS CONTROL PROGRAM BASES Page TRM I B 3.12-1 Page TRM /B 3.12-2 Page TRM I B 3.12-3 08131./1998 10/23/1998 08/31/1998 03/27/2007 08123/1999 08/31/1998 02/01/1999 04/07/2000 02101/1999 12/03/2004 02/01/1999 08/31/1998 04/0212002 05/13/2005 11114/2006 06/18/2013 01/21/2004 08/31/1998 11/30/2005 02/19/2015 05/29/2013 08/31/1998 06/30/2010 08/31/1998 02/1 2/1 999 09/19/2007 11/29/2010 02/05/1999 I.:?

TRM2 text LOES.doa 11JA3712015 SUSQUEHANNA - UNIT 2 TRM / LOES-9 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM ] :LOES-9 EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring instrumentation Rev. 8 3.3.4 3.3 'Instr'umentation 3.3.4 I]RM Post-Accident Monitoring Instrumentation TFRO 3.3.4 The TRM post-accidant monitoring instrumentation channels shown in T]able 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.4-i ACTi3ONS NOTES

1. Separate condition entry is allowed for each Function.
2. The provisions of TRO 3.05 are not applicable.

,CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Enter the Condition Immediately channel inoperable, referenced in Table 3.3.4-1 for the channel.

B3.

As required by Required 8].1 Initiate the preplanned 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Action A.1 and referenced alternate method of in Table 3.3.4-1.

monitoring the appropriate parameter(s).

AND 8.2 Restore the required channel 7 days / 30 days (*

to OPERABLE status.

C. As required by Required C.1 Restore the required 3D days Action A.1 and referenced channel(s) to OPERABLE in Table 3.3.4-1 status.

D.

As required by Required DA1 Verify a minimum 14 of the immediately Action A.1 and referenced associated acoustic monitor in Table 3.3.4-1 channels and 5 of the ADS AND SRV acoustic monitor channels are operable.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter (c),COMPLETION TIME for REQUIRED ACTION 8.2 is extended from 7 days to 30 days during construction activities associated with the replacement of SPING equipment with VERMS equipment.

SUSQUEHANNA-UNIT2 TRM / 3.3-9 SUSQEHANA

-UNIT2 TM 133-9EFFECTIVE DATE 10/0712015

TRM Post Accident Monitoring instrumentation 3.3.4 Rev. 8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME OR D.2 Verify SRV tailpipe Immrediately temperature indication and alarm are available for the AND tailpipe associated with the inoperable acoustic monitor.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter OR D.3 Verify that the following Immediately alternate mnonitoring methods in TS Table 3.3.3.1-1 are OPERABLE:

AND o Function 1 S

Function 2 Function 3 Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />

  • Function 10 thereafter AND 0.4.

Restore the required 30 days channel(s) to OPERABLE status.

OR_

At next outage with containment entry, not to exceed the next refueling outage for in-accessible containment components.

SUSQUEHANNA - UNIT 2 T*

! 3.3-9a SUSQEHANA UNT 2 RM 3.-9aEFFECTIVE DATE 061.3012010

TRM Post Accident Monitoring instrumentation 3.3.4 Rev. 8 TECHNICAL REQUIREMENT SURVEILLANCE

1.

Refer to Table 3.3.4-1 to determine which TR*s apply for each Post Accident Monitoring Function.

2.

W~hen a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or an associated function is available.

1 SURVEILLANCE FREQUENCY TRS 3.3.4.1 Perform CHANNEL CHECK 31 days TRS 3.3.42.

Perform CHANNEL FUNCTIONAL TEST 92 days TRS 3.3.4.3 Perform a CHANNEL CALIBRATION. The Trip 24 months Setpoint shall be less than or equal to 0.25 of the full open noise level.

TRS 3.3.4A4 Perform CHANNEL CALUBRATION 24 months TRS 3.3.4.5 Perform CHANNEL CALIBRATION of the Primary 92 days Containment H2 and 02 Analyzers.

.9P I

TRM ! 3.3-10 SUSQEHANA UNT 2 RM 3.-10EFFECTIVE DATE 1013112007

TRM Post Accident !Monitoring Instrumentation

,Q.Rev.

8 3.3.4 TABLE 3.3.4-1 TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OThER REFERENCED SPECIFIED REQUIRED

FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE
1.

Suppression Chamber Air 1.2 2

C TRS 3.3.4.1 Temperature TRS 3.3.4.4

2.

Main Steam Safety/Relief Valve 1,2 1/valve D

TRS 3.3.4.1 Position Indicator (Acoustic TRS 3.3.4.2 Monitor)

TRS 3.3.4.3

3. Reactor Building Vent Noble Gas Monitor
a. Mid Ranger°

.1,2, (a) 1 B

TRS 3.3.4.1 TRS 3.3.4.4 Sb.

High Range* 1 1,2, (a) 1 B

TRS 3.3.4.1

~TRS 3.3.4.4

4. Standby 'Gas Treatment System Vent Noble Gas Monitor
a. Mid Range(b) 1,2, (a) 1 B

TRS 3.3.4.1 TRS 3.3.4..4

b. High Range(b) 1,2, (a)

I B

TRS 3.3.4.1 TRS 3.3.4.4

5.

Turbine Building Vent Noble Gas Monitor

a. Mid Range(b) 1,2 1

B TRS 3.3.4.1

"]'RS 3.3.4.4

b. High Range'(b) 1,2 1

B TRS 3.3.4.1 TRS 3.3.4.4 (continued)

SUSQUEHANNA - UNIT 2 TRM 1 3.3-11 EFFECTIVE DATE 1010712015

I Rev. 8 TIRM Post Accident Monitoring instrumentation 3.3.4 TABLE 3.3.4-1 (conhinued)

TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECiFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITlONS

'CHANNELS ACTION A.1 SURVE]LI_.ANCE

6. Standby Gas Treatment System Vent Stack Sampling System Flow I
a. Effluent System 1,2,,(a) 1 C

TRS 3.3.,4.1 flow rate monitor~b TRS 3.3.4.4

b. Sampler flow rate 1,2, (a)

IC TRS 3.3.4.1 monitor~b TRS 3.3.4.4

7. Turbine Building Vent Stack Sampling System Flow
a. Effluent System flow rate monitor(b) 1,2 1C TRS 3.3.4.1 TRS 3.3.4.4
b. Sampler flow rate monitor~b 1,2 1C TFRS 3.3.4.1.

T[RS 3.3.4.4

8.

Containment H2 and 02 1,2 2

C T[RS 3.3.4.1 Analyzer(b)

TRS 3.3.4.5 (a) When moving irradiated fuel in the secondary containment.

(b) TRO 3.0.4.c is applicable.

SUSQUEHANNA - UNIT 2 TRM 1 3.3-11a SUSQEHANA UNT 2 RM 3.-haEFFECT IVE DATE 1010712015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The primary purpose of the TRM PAM instrumentation is to.display plant variables that provide information required by the control room operators during accident situations. The OPERABIL ITY of the TRM PAM instrumentation ensures that the identified information is available on selected plant parameters to monitor and assess important variables ;following an accident_ This capability is,consistent with the recommendations of Regulatory Guide 1.97 Revision 2, i]nstrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant Conditions During and following an Accidentf NUREG-0578, 'qTMl-2 Lessons i.eamed Task Force Status Report and Short-Term Recommendations= and NEDO-331 60-A Revision 1, *Regulatory Relaxation For The Post Accident SRV Position Indication System= (Reference 6). It should be noted that the Technical Specificatio~ns LCO 3.3.3.1 contains all,Category 1, non-type A instruments and Regulatory Guide 1.97 Type A instrument (References 1 and 2). This TRO requires instruments outside of these criteria.

Table 3.3.4-1 identifies the following required Functions. Suppression Chamber Air Temperature provides a post accident indication of problems with the primary containment pr:essure suppre.ssion system. The Suppression Chamber Air Temperature loops are comprised of the following instruments for the purposes of this TRM. The recorders are the primary method of indicaton used by operator during an accident; therefore, the PAM specification deals specifically with this portion of the instrument.

LOOPA.

LOOP B TE-25703 TE-25725 TT-25703 TT-25725 TR-25795A TR-25795B Main Steam SafetylRelief Valve Positon lndicators (Acoustic Monitors) provide indication when the valves are functioning. Alternate methods for monitoring SRV position include SRV Tailpipe TemPerature and the following Functions from Technical Specification Table 3.3.3.1-1:

Suppression Chamber Water Level (Function 3)]

Suppression,Chamber Water Temperature (Function 10)

Reactor Vessel Water Level (Function 2)

Reactor Steam Dome Pressure (Function 1)]

,(continued)

SUSQUEHANNA - UNIT 2 TRM ] B 3.3-4 SUSQEHANA

-UNI 2 RM IB 33-4EFFECTIVE DATE 06130/2010

TRM Post Accident Monitoring Instrumentation B 3.3A Rev. 5 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES I

TRO (continued)

The required channels for REACTOR BUILDING VENT Noble Gas Monitor, Standby Gas Treatment System Vent Noble Gas Monitor. and Turbine Building Vent Noble Gas Monitor provide information regarding the release of radioactive materials to allow for early indication,of the need ;to initiate action necessary to protect the public and for an estimate of the magnitude of any impending threat.

For the Noble Gas Monitors the,only required channels are the mid range and high range.

The drywell and suppression,chamber hydrogen and oxygen concentrations gas analyzers monitor hydrogen and oxygen concentration to detect combustible gas levels in primary containment The analyzers are capable of determining hydrogen concentration in the range of 0 to 30% by volume and oxygen concentration in the range of 0 to 10% by volume, and each provide control room indication and output to a control room recorder. Each gas analyzer mus~t be capable of sampling either the drywell or the suppression chamber. The recorders are the primary method of indication available for use by the operator during an accident2 therefore the PAM Specification deals specifically with this portion of the instrument channel. The gas analyzer piping is provided with heat tracing to reduce the buildup of condensatidn in the system. 1H202 Aihalyzers can be considered OPERABLE for accident monitoring for up to 100 days with their heat tracing INOPERABLE.

0 ACTIONS The Actions are defined to ensure proper corrective measures are taken in response to the inoperable components.

During construction activities that replace existing SPING equipment with new VERMS equipment, the Vent Noble Gas Monitor for each release path is anticipated to be inoperable for longer than 7 days. Restoration completion time to return the affected channel to OPERABLE status to support,construction activities is extended to 30 days. This condition is compensated for by the enhanced Preplanned Alternate Monitoring Plan per REQUIRED ACTION B3.1.

(continued)

SUSQUEHANNA - UNIT 2 TRM /:B 3.3-5 SUSQEHANA

-UNI 2 RM IB 33-5EFFECTIVE DATE "1010712015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES ACTIONS (continued)

Action D :requirements were determined by balancing the safety significance of the system with the impact of the actions on the operating unit_ The 'loss of the acoustic monitors is not safety significant providing the diverse and redundant alternate methods of determining SRV position are available. System components in the control room are restorable witin 30 days without unit operation impact. Components located in containment require a unit shutdown to gain access to individual components.,The system channels shall be restored to operable condition at eaiiiest opportunity.

Noble gas monitoring may be interrupted for up to 30 minutes to perform particulate filter/iodine cartridge changeout required by TRM Table 3.11.2-1 without entering,the TRO ACT*IONS.

Components,of alternate SRV position systems may be taken inoperable for routine surveillances and periodic maintenance providing the appropriate LCO requirements are met during this action statement. Tailpipe temperature is the direct process monitoring, alternate method and is not covered by Technical Specification LCO's as are the other alternative methods.

TRS The Technical Requirement Surveillances (TRS) are :modified by two Notes.

Note I states that the TRSs for each Post Accident Monitoring instrumentation Function are located in the SR column of Table 3.3.4-1.

Note 2 modifies the Surveillances to indicate that when a channel is placed in a inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or associated Function are available. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B 3.3-6 SUSQEHANA

-UNI 2 RM IB 33-8EFiFECTIVE DATE 10/0712015

TRM Post Accident Monitoring ilnstrumentation Rev. 5 B 3.3.A B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS (continued)

The alternate means of monitoring the parameter or The associated function are:

P~r'nmtf*r Suppression Chamber Air Temperature Main Steam SafetylRellief Valve Position 1Indilcator Containment IH2 and 02 Analyzer One channell of Suppressioen Cihamber Air Temperature Suppression Pool levell Suppression [Pooll Temperature RPV 1level RPV pressure SRV Tailpilpe Temaperature One channel of Containment 1-1 and '02 The TRSs are defined to be peif~ormed at the specified Frequency to ensure that the TRM PAM Function is maintained OPERABLE

((continued)

SUSQUEHANNA - UNIT 2 TRM/B &3*

SUSUEHNNA-UIT TR I 3~-7EFFECTIVE DATE 101.0,712015

F i

~TRM :Post Accident Monitoring Instrumentation SRev.

5 B 3.3.4 O :-

B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS TRS 3.3.4.1 (continued)

Performance of the CHANNEL CHECK once every 31 days ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel against a similar parameter on other channels. it is based.on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations be tween instrument channels could be an indication of excessive instrument drift in one of the :channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to opefate properly between each CHANNEL CALIBRATION.

Agreement criteria, which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability..

If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit and does not necessarily indicate the channel is inoperable.

O ':-REFERENCES

1.

Regulatory Guide 1.97 Revision 2, "instrumentation for Light Water Cooled Nuclear 'Power Plants to Assess Plant and Environs Conditions During and Following an Accident.)'

2.

NUREG-0578, "iTMi-2 Lessons Learned Task Force Status Report and Short-Term Recommendations.=

3.

Technical Specification Amendment No. 100 to License No. NPF-22. for failed Unit 2 "S" acoustic monitor.

4.

Technical Specification Amendment No. 169 to License No. NPF-14 for failed Unit I US" acoustic monitor.

5.

Proposed amendment No. 183 to License No. NPF-22 failed Unit 2 "Jo acoustic monitor.

6.

NEDO-33160-A, Revision 1, ='Regulatory Relaxation For The Post Accident SRV Position Indication System,= dated October 2006.1

7.

NRC letter, "Final Safety Evaluation For Boiling Water Reactor Owners' Group (BWROG) Topical Report (TR) NEDO-33160, Regulatory Relaxation For The Post Accident SRV [Safety Relief Valve] Position

~Indication System.(TAG No. MC5446)," dated September 26, 2005.

SUSQUEHANNA - UNIT 2 TRM/B3.3*

SUSQEHANA-UIT TRMlB 33-8EFFECTIVE DATE 0613012010

Oct.

15, 2015 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSHITTAL 2015-41364 USER INFORMATION:

GERLACH*ROSEY N EMPL# :028401 CA# :

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY M 10/15/2 015 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no T0C will be issued with the updated material.

TRMl TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 10/05/2015 ADD MANUAL TABLE OF CONTENTS DATE: 10/14/2015 CATEGORY:

DOCUMENTS TYPE: TRM1 pt0t

'V

Oct.

15, 2015 Page 2

of 2

ID:

TEXT 3.3.4 REMOVE:

REV:7 ADD:

REV:

8 CATEGORY:

DOCUMENTS TYPE: TRM1 ID:

TEXT B3.3.4 ADD:

REV:

5 REMOVE:

REV: 4 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE: TRMI LOES REV: 82 ADD:

REV:

83 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
  • SES MANUAL Manual an~e:

TEMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:

10/ 14/2 015 Procedure Name Rev Issue Date TEXT LOES 83 10/14/2015

Title:

LIST OF EFFECTIVE SECTIONS Change ID Change Number TEXT TOC

Title:

25 04/28/2015 TABLE OF CONTENTS TEXT 1.1 1

01/31/2014 Til:USE AND APPLICATION DEFINITIONS TEXT 2.1 2

04/28/2015

Title:

PLANT PROGRAMS AND SETPOINTS PLANT-PROGRAMS° TEXT 2.2 10 7 °°0!/31/2014*

Title:

PLANT PROGRAMS AND SETP0ONTS ILNSTRUMENT TRIP SETPOINT TABLE TEXT 3.0

Title:

-**5*,

03705/2015 TECHNICAL REQUIREMENT F9R OPERATION (TRO) APPLICABILITY & SURVEILLANCE (TRS)

APPLICABILITY TET.11-1 11/09/2007 Title : REACTIVITY iCONqTROLh SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION I*ATWS-ARI )

INSTRUMENTATION TEXT 3.1.2 i

"*0 11/18/2002

Title:

REACTIVITY*ICONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3 5

04/16/2009

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0

11/18/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &

CHECK VALVE TEXT 3.2.1 15 04/28/2015

Title:

CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 16 Report Date: 10/15/15 Page !

of 16 Report Date: 10/15/15

SSES MANTJAT Manual Name:*

TRM1

  • iManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1 0

11/18/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4

Title:

INSTRUMENTATION 8

10/14/2015 TEN POST-ACCIDENT MONITORING INSTRUMENTATION LDCN 4552 TEXT 3.3.5 0

11/18/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3.3.6 4

04/29/2014

Title:

INSTRUMENTATION TEN ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 1

11/09/2007

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1

10/22/2003

Title:

INSTRUMENTATION TRM RPS INSTRUMENTATION TEXT 3.3.9 3

04/17/2008

Title:

OPEN INSTRUMENTATION CONFIGURATION TEXT 3.3.10 1

12/14/2004

Title:

INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015 S

Title:

WATER MONITORING INSTRUMENTATION 0

Page 2 of 16 Report Date: 10/15/15 Page 2 of 16 Report Date: 10/15/15

RSES MANUqAL Manual Namne:

TRMIl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.4.1

Title:

REACTOR TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.5.1 1

04/26/2006 COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM STRUCTURAL INTEGRITY 1

11/09/2007 COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS 2

04/17/2008 COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 1

04/26/2006 COOLANT SYSTEM REACTOR VESSEL MATERIALS 2

04/25/2013 RECIRCULATION SINGLE LOOP OPERATION SLO FLoW RATE RESTRICTION 1

02/04/2005

Title:

EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/18/2002

Title:

EMERGENCy CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/18/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3..6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/18/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page.3 of 16 Report Date: 10/15/15 Page.3 of i_66 Report Date: 10/15/15

SSES MANUJAIL Manual Name:*

TRMI

  • .Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.6.4 0

11/18/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1

Title:

PLANT TEXT 3.7.2

Title:

PLANT TEXT 3.7.3.1

Title:

PLANT TEXT 3.7.3.2

Title:

PLANT TEXT 3.7.3.3

Title:

PLANT TEXT 3.7.3.4

Title:

PLANT 0

11/18/2002 SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN 0

11/18/2002 SYSTEMS ULTIMATE HEAT SINK CUBS)

AND GROUND WATER LEVEL 2

04/16/2009 SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM 3

04/16/2009 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 04/16/2009 0

3 SYSTEMS C02 SYSTEMS 2

04/16/2009 SYSTEMS HALON SYSTEMS TEXT 3.7.3.5 2

04/16/2009

Title:

PLANT SYSTEMS FIRE HOSE STATIONS TEXT 3.7.3.6

Title:

PLANT TEXT 3.7.3.7

Title:

PLANT 2

04/16/2009 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 1

04/26/2006 SYSTEMS FIRE RATED ASSEMBLIES TEXT 3.7.3.8 10 09/27/2012

Title:

PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION TEXT 3.7.4 1

04/26/2006

Title:

PLANT SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 16 Report Date: 10/15/15 Page 4 of 16 Report Date* 10/15/15

M..i*

  • anual Name:

TRM1 SManual

Title:

TECHNICAL REQUIREMENTS MANU~IAL UNIT 1 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/18/2002

Title:

PLANT SYSTEMS MAIN CONDENSEROFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING S.TEXT 3.7.8 5

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 2

01/31/2014

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 1

12/14/2004 Ti~le: PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.11 0

04/16/2009

Title:

STRUCTURAL INTEGRITY TEXT 3.8.1 2

04/05/2010

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION CONTINUOUS h

TEXT 3.8.2.2 2

12/14/2004 F.

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMVAL OVERLOAD PROTECTION AUTOMATIC Pae/o 6RprtDt:1/51 Page

  • of 16 Report Date: 1,0/15/15

SSES MANTTAI Manual N~ame:

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANU]TAL UNIT 1 TEXT 3.8.3 Title : ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7 2

03/05,/20*15 POWER DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/18/2002 POWER 24 VTDC ELECTRICAL POWER SUBSYSTEM 1 '

11/14/2013 POWER DEGRADED VOLTAGE PROTECTION

  • 1 12/08/2011 POWER EMERGENCY SWITCHGEAR ROOM COOLING
  • 1 06/15/2009

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9.1 0

11/18/20026

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/18/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/18/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006

Title:

MISCELLANEOUS SEAL SOURCE CONTAMINATION

'TEXT 3.10.2 2

08/08/2006

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 2

04/17/2008

  • Title: MISCELLANEOUS LEADING EDGE FLOW M~ETER (LEFM)6 Page 6 of i_66 Report Date: 10/15/15

SSES MANUAL*

O *Manual Name:

TRM1 W:*

Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.1

Title:

RADIOACTIVE TEXT 3.11.1.2

Title:

RADIOACTIVE TEXT 3.11.1.3

Title:

RADIOACTIVE TEXT 3.11.1.4

Title:

RADIOACTIVE TEXT 3.11.1.5

Title:

RADIOACTIVE TEXT 3.11.2.1

Title:

RADIOACTIVE TEXT 3.11.2.2

Title:

RADIOACTIVE TEXT 3.11.2.3

Title:

RADIOACTIVE FORM TEXT 3.11.2.4

Title:

RADIOACTIVE.

TEXT 3.11.2.5

Title:

RADIOACTIVE TEXT 3.11.2.6

Title:

RADIOACTIVE TEXT 3.11.3

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1

04/26/2006 LIQUID EFFLUENTS CONCENTRATION 1

04/26/2006 LIQUID EFFLUENTS DOSE 1

04/26/2006 LIQUID WASTE TREATMENT SYSTEM 2

10/09/2012 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION

.3 03/05/2015 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 3

04/26/2006 DOSE RATE 1

04/26/2006 DOSE -

NOBLE GASES 1

04/26/2006 DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE 0

11/18/2002 GASEOUS RADWASTE TREATMENT SYSTEM 4

07/03/2013 VENTILATION EXHAUST TREATMENT SYSTEM 5

04/28/2015 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION 1

04/26/2006 TOTAL DOSE Page 2 of 16 Report Date: 10/15/15 Page 7--

of i__66 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRMI i Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.4.1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1 0

11-/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT 4.1

Title:

TEXT 4.2

Title:

TEXT 4.3

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

0 08/31/1998 ADMINISTRATIVE CONTROLS ORGANIZATION ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

08/31/1998 CONTROLS REPORTABLE EVENT ACTION 0

08/31/1998 CONTROLS SAFETY LIMIT VIOLATION 1

12/18/2008 CONTROLS PROCEDURES & PROGRAMS 0

08/31/1998 CONTROLS REPORTING REQUIREMENTS 0

08/31/1998 CONTROLS RADIATION PROTECTION PROGRAM Page 8 of 16 Report Date: 10/15/15 Page of 16 Report Date: 10/15/15

SSES M~ANUAL Manual Name :

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4.7 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS TRAINING TEXT B3.0 5

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION CTRO)

APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT B3.1.3 3

03/31/2006

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.1 0

11/19/2002

Title:

CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)

TEXT B3.3.1

Title:

INSTRUMENTATION TEXT B3.3.2

Title:

INSTRUMENTATION TEXT B3.3.3

Title:

INSTRUMENTATION TEXT B3.3.4

Title:

INSTRUMENTATION TEXT B3.3.5

Title:

INSTRUMENTATION 1

01/31/2014 BASES RADIATION MONITORING INSTRUMENTATION 2

03/31/2011 BASES SEISMIC MONITORING INSTRUMENTATION 3

12/18/2008 BASES METEOROLOGICAL MONITORING INSTRUMENTATION 5

10/14/2015 BASES TRN POST ACCIDENT MONITORING (PAN)

INSTRUMENTATION LDCN 4552 2

11/09/2007 BASES THIS PAGE INTENTIONALLY LEFT BLANK Pages of 16 Report Date: 10/15/15 Page 9--

of 166 Report Date: 10/15/15

SSES MA1~1TJAL Manual Name :

TRMI

-Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.3.6

Title:

INSTRUMENTATION BASES 5

01/31/2014 TRN ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7 1

11/09/2007

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22./2003

Title:

INSTRUMENTATION BASES TEN REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION TEXT B3.3.9

Title:

OPEN INSTRUMIENTATION TEXT B3o3.10

Title:

INSTRUMENTATION BASES STEXT B3.3.11

Title:

INSTRUMENTATION BASES TEXT B3.3.12 3

04/17/2008 3

08/09/2010 REACTOR RECIRCULATION PUMP MG SET STOPS 1

10/22/2003 MVP ISOLATION INSTRUMENTATION 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1

Title:

REACTOR TEXT B3.4.2

Title:

REACTOR TEXT B3o4.3

Title:

REACTOR TEXT B3.4.4

Title:

REACTOR TEXT B3.4.5

Title:

REACTOR 0

11/19/2002 COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM BASES STRUCTURAL INTEGRITY 1

11/09/2007 COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR 0

11/19/2002 COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 0

11/19/2002 COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 10 of 16 Report Date: 10/15/15 Page 100 of 16 Report Date: 10/15/15

S~ES MANUAL Manual Name:

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.4.6 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW PATE RESTRICTION TEXT B3.5.1 0

11/19/2002

Title:

ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 1*

11/09/2007

Title:

ECCS AND RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMETATION TEXT B3.5.3 1

11/09/2007

Title:

ECCS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2

04/17/2008

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1 0

11/19/2002

Title:

PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)

TEXT B3.7.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UIES)

GROUND WATER LEVEL TEXT B3.7.3.1 3

06/15/2010

Title:

PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM STEXT B3.7.3.2 2

04/26/2006 i

Title:

PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS Page i!i of 16 Report Date: 10/15/15

SSES MANUJAI Manual flame:

TRMI

'- Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 0

TEXT B3.7.3.3

Title:

PLANT TEXT B3.7.3.4

Title:

PLANT TEXT B3..7.3.5 Title : PLANT TEXT B3.7.3.6 Title : PLANT TEXT B3.7.3.7 Title :

PLANT TEXT B3 7.3.8 Title : PLANT TEXT B3.7.4 Title :

PLANT TEXT B3.7.5.1 Title :

PLANT TEXT B3.7.5.2 Title : PLANT TEXT B3.7.5.3 Title : PLANT TEXT B3.7.6

Title:

PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0

11/19/2002 C02 SYSTEMS 3

04/29/2014 HALON SYSTEMS 1

04/26/2006 FIRE HOSE STATIONS 1

04/26/2006 YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 FIRE RATED ASSEMBLIES 3

09/27/2012 FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SOLID RADWASTE SYSTEM 0

11/19/2002 MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/19/2002 MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002 LIQUID HOLDUP TANKS 4

06/04/2013 ESSW PUMPHOUSE VENTILATION 2

01/31/2008 TEXT B3.7.7

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION-MONITORING INSTRUMENTATION Page 12 of 16 Report Date: 10/15/15

SSES MAAL Manual Name:

TEdKI I: Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.8

Title:

PLANT TEXT B3.7.9

Title:

PLANT TEXT B3.7.10

Title:

PLANT 4

SNUBBERS 01/3 1/2 014 SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 2

12/08/2011 CONTROL STRUCTURE HVAC 1

12/14/2004 SPENT FUEL STORAGE POOLS TEXT B3.7.11

Title:

STRUCTURAL INTEGRITY 1

04/14/2010 TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL TEXT B3.8.5

Title:

ELECTRICAL TEXT B3.8.6

Title:

ELECTRICAL TEXT B3.8.7 2

03/10/2010 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 1

09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 0

11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 1

11/14/2013 POWER BASES DEGRADED VOLTAGE PROTECTION 2

12/08/2011 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 2

06/04/2013 PROTECTION -

PROTECTION -

Titles BATTERY MAINTENANCE AND MONITORING PROGRAM Page 13 of 16 Report Date: 10/15/15 Page i__33 of 16 Report Date: 10/15/15

SSES MANTJAI Manual Name :

TRMI

  • Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1

03/31/2006

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.10.4 1

04/17/2008

Title:

MISCELLANEOUS BASES LEADING EDGE FLOW METER (LEFM)

TEXT B3

.11.1.

Title:

RADIOACTIVE TEXT B3.11.1.2

Title:

RADIOACTIVE TEXT B3.11.1.3

Title:

RADIOACTIVE TEXT B3.11.1.4

Title:

RADIOACTIVE 0

11/19/2002 BASES LIQUID EFFLUENTS CONCENTRATION EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 0

BASES 11/19/2 002 LIQUID EFFLUENTS DOSE 0

11/19/2002 BASES LIQUID WASTE TREATMENT SYSTEM 0

11/19/2002 BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION Page 14 of 16 Report Date: 10/15/15 Page IA4 of 16 Report Date: 10/15/15

SSE~S MANUAL O ~iManual Name:

TRMI W**

Manual

Title:

TECHNICAL REQUIRETMENTS MANUAL UNIT 1 TEXT B3.11.2.1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

NOBLE GASES TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM TEXT B3.11.2.4

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.12.1

Title:

LOADS CONTROL PROGRAM TEXT B3.12.2

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 BASES DOSE -IODINE,

TRITIUM, AND RADIONUCLIDES IN 0

11/19/2002 BASES GASEOUS RADWASTE TREATMENT SYSTEM 5

07/03/2013 BASES VENTILATION EXHAUST 1

01/27/2004 BASES RADIOACTIVE GASEOUS TREATMNT SYSTEM EFFLUENT MONITORING 0

11/19/2002 BASES TOTAL DOSE 5

03/05/2015 BASES MONITORING PROGRAM 0

11/19/2002 BASES LAND USE CENSUS 0

11/19/2002 BASES INTERLABORATORY COMPARISON PROGRAM 1

10/04/2007 BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL 1

12/03/2010 BASES HEAVY LOADS REQUIREMENTS Page i5~

of 16 Report Date: 10/15/15 Page 15 of 16 Report Date: 10/15/15

SSES MANAL Manual Name :

TRMI SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS Page 16 of 16 Report Date: 10/15/15 Page 16 of 16 Report Date: 10/15/15

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC 1.0 TABLE OF CONTENTS USE AND APPLICATION Page TRM / 1.0-1 Page TRM / 1.0-2 Page TRM / 1.0-3 2.0 3.0 PLANT PROGRAMS Page TRM / 2.0-1 Pages TRM / 2.0-2 and TRM / 2.0-3 Page TRM / 2.0-4 Page TRM / 2.0-5 Page TRM / 2.0-6 Page TRM / 2.0-7 Pages TRM / 2.0-8 and TRM / 2.0-9 Page TRM / 2.0-10 Page TRM / 2.0-11 Page TRM /2.0-12 Pages TRM / 2.0-13 and TRM / 2.0-14"\\,

Page TRM / 2.0-15

/,

\\

\\

-\\

O 3.1 3.2 3.3 APPLICABILITY

Y' Pages TRM / 3.0-1 and TR

/3.0-2 Page TRM /3.0-3

/..**,

Page TRM / 3.0-4

' '7/

REACTIVITY CONTROL SYSTEMS Page TRM / 3.i-1,

\\

Pages TRM /'3~.'1,2 anid Tl*M / 3.1-3 Pages 3.1-4 an*d,31-,5 \\

Page TRMI 3.-1-6,,

Page-TRM / 3.11*

Page TRM /'3.'1-8 Pages RM / 3.1-9 and TRM / 3.1-9a

/,P a~geTRM/'3.1-10

\\CORgE OPERATING LIMITS REPORT

',Page TRM / 3.2-1 Pages TRM / 3.2-2 through TRM / 3.2-54 INSTRUMENTATION Pages TRM / 3.3-1 through TRM / 3.3-3 Page TRM / 3.3-4 and TRM / 3.3-5 Page TRM / 3.3-6 04/2312015 10/04/2002 01/21/2014 10/04/2002 04/23/2015 0 1/28/2005 06/25/2002 01/21/2014 03/27/2008 05/15/2008 01/07/2011 02/02/2010 11/15/2004 03/27/2008 11/15/2004 11/15/2005 02/19/2015 03/15/2002 02/19/2015 10/31/2007 08/31/1998 08/31/1998 03/22/2006 04/07/2009 03/27/2008 02/18/1999 02/18181999 07/07/1999 04/21/2015 07/16/1 999 10/31/2007 03/10/2011 SUSQUEHANNA

- UNIT I TRM/LOES-1 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-1 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM / 3.3-7 Page TRM / 3.3-8 Page TRM / 3.3-9 Page TRM I 3.3-9a Page TRM / 3.3-10 Page TRMI/3.3-11 Page TRM / 3.3-11a Page TRM / 3.3-12 Page TRM / 3.3-13 Page TRM / 3.3-14 Page TRM I 3.3-15 Page TRM I 3.3-16 Page TRM / 3.3-17 Page TRM / 3.3-18 Pages TRM / 3.3-19 through TRM / 3.3-21 Page TRM / 3.3-22 Page TRM / 3.3-22a Pages TRM / 3.3-22b through TRM / 3.3-22d Page TRM / 3.3-23 Pages TRM / 3.3-24 and TRM / 3.3-25 Page TRM / 3.3-26 Page TRM / 3.3-27 Page TRM / 3.3-28 REACTOR COOLANT SYSTEM Page TRM / 3.4-1 Pages TRM / 3.4-2 through TRM / 3.4-5 Pages TRM / 3.4-6 through TRM / 3.4-8 Page TRM / 3.4-9 Page TRM / 3.4-10 Page TRM / 3.4-11 Page TRM / 3.4-12 Page TRM I 3.4-13 Pages TRM / 3.4-14 and TRM I 3.4-15 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 Pages TRM I 3.5-2 and TRM / 3.5-3 Pages TRM / 3.5-4 and TRM / 3.5-5 Pages 3.5-6 and 3.5-7 10/31/2007 08/31/1998 10/07/2015 06130/2010 10/31/2007 10/07/2015 10/07/2015 03/30/2001 01/07/2011 12/14/1 998 04/11/2014 01/07/2011 06/14/2002 10/31/2007 10/22/2003 03/27/2008 11/15/2004 03/22/2006 12/03/2004 05/16/2003 10/22/2003 02/19/2015 04/07/2009 03/31/2006 10/23/1998 04/01/2009 08/31/1998 10/31/2007 08/31/1998 03/27/2008 03/31/2006 04/25/2013 01/28/2005 08/31/1998 10/31/2007 08/31/1998 3.4 3.5 SUSQUEHANNA,- UNIT 1 TRM / LOES-2 SUSQEHANA-UITITRM LOS-2 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.6 3.7 CONTAINMENT Page 3.6-1 Pages TRM / 3.6-2 and TRM / 3.6-2a Page 3.6-3 Page TRM / 3.6-4 Page 3.6-5 Pages TRM / 3.6-6 through TRM I 3.6-8 PLANT SYSTEMS Pages 3.7-1 through 3.7-3 Page TRM / 3.7-4 Pages TRM / 3.7-5 Pages TRM / 3.7-6 through TRM I 3.7-8 Pages TRM / 3.7-9 and TRM / 3.7-10 Page TRM / 3.7-11 Page TRM / 3.7-12 Page TRM / 3.7.13 Page T.RM / 3.7-14 Pages TRM / 3.7-15 and TRM / 3.7-16 Page TRM / 3.7-17 Page TRM / 3.7-18 Page TRM / 3.7-19 Pages TRM / 3.7-20 through TRM / 3.7-22 Page TRM / 3.7-23 Page TRM / 3.7-24 Page TRM / 3.7-25 Page TRM / 3.7-26 Page TRM I 3.7-27 Pages TRM / 3.7-28 through TRM I 3.7-34a Page TRM / 3.7-35 Pages TRM / 3.7-36 and TRM / 3.7-37 Page TRM / 3.7-38 Page TRM / 3.7-39 Page TRM / 3.7-40 Page TRM / 3.7-41 Pages TRM I 3.7-41a through TRM / 3.7-41c Page TRM / 3.7-42 Page TRM / 3.7-43 Page TRM / 3.7-44 Pages TRM / 3.7-45 and TRM / 3.7-46 Page TRM / 3.7-47 08/31/1998 04/16/2014 08/31/1998 01/07/2002 08/31/1998 12/31/2002 08/31/1998 03/31/2006 04/07/2009 08/02/1999 04/07/2009 12/29/1999 08/02/1999 04/07/2009 08/09/2005 08/02/1999 04/07/2009 08/02/1999 04/07/2009 08/02/1999 04/07/2009 03/31/2006 08/02/1999 09/25/2012 11/24/2011 09/25/2012 03/31/2006 02/01/1999 02/19/2015 08/31/1998 03/31/2006 05/24/2012 05/24/2012 09/04/2008 08/31/1998 02/19/2015 10/05/2006 06/07/2007 SUSQUEHANNA

- UNIT I TRM / LOES-3 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-3 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECH NICAL REQUIREM ENTS MAN UAL)

Section Title Effective Date 3.8 Page TRM / 3.7-48 Page TRM / 3.7-49 Pages TRM / 3.7-49a and TRM / 3.7-49b Page TRM / 3.7-50 Page TRM I 3.7-51 Page TRM / 3.7-52 Page TRM / 3.7-53 Page TRM / 3.7-54 Pages TRM / 3.7-55 through TRM / 3.7-57 ELECTRICAL POWER Page TRM / 3.8-1 Page TRM / 3.8-2 Pages TRM / 3.8-3 and TRM /3.8-4 Pages TRM / 3.8-5 and TRM / 3.8-6 Page TRM / 3.8-7 Pages TRM / 3.8-8 through TRM I 3.8-10 Page TRM / 3.8-11 Page TRM / 3.8-12 Page TRM / 3.8-13 Page TRM / 3.8-14 Pages TRM / 3.8-15 through TRM ! 3.8-17 Page 3.8-18 Page TRM I 3.8-19 Page 3.8-20 Pages TRM / 3.8-21 and TRM / 3.8-22 Page TRM / 3.8-23 Pages TRM / 3.8-24 and TRM / 3.8-25 Page TRM / 3.8-26 Page TRM / 3.8-27 Pages TRM / 3.8-28 and TRM I 3.8-29 10/05/2006 06/07/2007 10/05/2006 01/21/2014 08/16/2006

  • 12103/2004 04/15/2003 07/29/1999 04/01/2009 04/02/2002 01/28/2005 03/25/2010 04/02/2002 10/31/2007 12/03/2004 09/03/2004 12/03/2004 02/19/2015 08/31/1998 04/02/2002 08/31/1998 04/02/2002 08/31/1998 06/06/1999 11/07/2013 11/30/2011 05/28/2009 11/29/2006 05/28/2009 08/31/1998 03/31/2006 08/31/1998 08/01/2006 03/22/2006 06/10/2010 03/27/2008 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 M ISCELLANEOUS Page TRM / 3.10-1 Pages TRM / 3.10-2 and TRM / 3.10-3 Page TRM / 3.10-4 Pages TRM / 3.10-5 and TRM / 3.10-6 Page TRM / 3.10-7 Page TRM / 3.10-8 SUSQUEHANNA

- UNIT I TRM / LOES-4 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-4 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.11 RADIOACTIVE EFFLUENTS Page TRM / 3.11-1 Pages TRM / 3.11-2 and TRM / 3.11-3, Page TRM / 3.11-4 Page TRM / 3.11-5 Page TRM / 3.11-6 Pages TRM / 3.11-7 and TRM I 3.11I-8 Pages TRM / 3.11-9 and TRM / 3.11-10 Pages TRM /3.11-11 and TRM /3.11-12 Page TRM / 3.11-13 Page TRM / 3.11-14 Pages 3.11-15 and 3.11-16 Page TRM /3.11-17 Page 3.11-18 Page TRM / 3.11-19 Pages TRM / 3.11-20 and TRM / 3.11-21 Page TRM / 3.11-22 Page TRM / 3.11-23 Page TRM / 3.11-24 Page TRM / 3.11-25 Pages TRM / 3.11-26 and TRM / 3.11-27 Page TRM / 3.11-28 Page TRM / 3.11-29 Pages TRM / 3.11.30 and TRM /3.11.31 Page TRM / 3.11.32 Page TRM / 3.11-33 Page TRM / 3.11-34 Page TRM / 3.11-35 Pages TRM / 3.11-36 through TRM / 3.11-39 Page TRM I 3.11-40 Pages TRM / 3.11-41 through TRM / 3.11-43 Page TRM / 3.1,1-44 Page TRM / 3.11-45 Page 3.11-46 Page TRM / 3.11 LOADS CONTROL PROGRAM Pages TRM / 3.12-1 through TRM / 3.12-3 Page TRM / 3.12-4 Page TRM / 3.12-5 03/31/2006 08/31/1998 03/31/2006 08/31/1998 03/31/2006 08/31/1998 10/09/2012 08/31/1998 02/19/2015 12/03/2004 09/01/1998 03/31/2006 08/31/1998 08/15/2005 03/31/2006 04/02/2002 11i/14/2006 06/18/2013 04/12/2007 01/21/2004 09/08/2009 12/03/2004 01/21/2004 04/23/2015 03/31/2006 08/31/1998 03/31/2006 11/30/2005 02/19/2015 08/31/1998 08/01/2006 03/31/2006 08/31/1998 03/31/2006 02/05/1999 03/14/2008 02/05/1999 08/31/1998 12/11/2008 08/31/1998 3.12 4.0 ADMINISTRATIVE CON~TROLS Pages 4.0-1 through 4.0-3 Page TRM / 4.0-4 Pages 4.0-5 through 4.0-8 SUSQUEHANNA - UNIT I TRM / LOES-5 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-5 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MAN UAL)

Section Title B 3.0 APPLICABILITY BASES Pages TRM / B 3.0-1 through TRM / B 3.0-3 Page TRM / B 3.0-4 Page TRM / B 3.0-4a and TRM I B 3.0-4b Page TRM / B 3.0-5 Page TRM / B] 3.0-6 Page TRM / B 3.0-7 Pages TRM / B 3.0-8 through TRM / B 3.0-10 Pages TRM / B 3.0-11 and TRM / B] 3.0-12 Pages TRM / B 3.0-13 through TRM / B] 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Page TRM / B 3.1-1 Page TRM / B 3.1-2 Page TRM / B 3.1-3 Page B] 3.1-4 Page TRM / B 3.1-5 Pages TRM / B] 3.1-6 and TRM / B 3.1-7 Page TRM / B 3.1-8 Effective Date 08/31/1998 02/19/2015 02/19/2015 02/19/2015 08/31/1998 04/12/2007 08/31/1998 03/15/2002 02/19/2015 B 3.1 B 3.2 B 3.3' CORE OPERATING LIMITS BASES Page B 3.2-1 INSTRUMENTATION BASES Page TRM / B] 3.3-1 Page TRM / B 3.3-2 Page TRM / B 3.3-2a Page TRM / B 3.3-3 Page TRM / B 3.3-3a Page TRM / B 3.3-4 Page TRM / B 3.3-5 Page TRM / B 3.3-6 Page TRM / B 3.3-7 Page TRM / B. 3.3-8 Page TRM / B 3.3-9 Pages TRM / B 3.3-10 through TRM / B 3.3-12 Page TRM /B 3.3-13 Page TRM / B 3.3-14 Page TRM / B 3.3-14a Page TRM / B 3.3-14b Pages TRM / B 3.3-15 and TRM / B 3.3-16 Page TRM / B 3.3-17 Pages TRM / B 3.3-17a through TRM / B 3.3-17c Page TRM / B] 3.3-17d 07/1 3/1 999 04/16/2014 10/31/2007 08/31/1998 11/15/2005 03/22/2006 02/18/1999 08/31/1998 01/21/2014 03/10/2011 10/31/2.007 12/11/2008 10/31/2007 06/30/2010 10/07/2015 06/30/2010 10/07/2015 06/30/2010 10/31/2007 01/07/2011 01/21/2014 06/25/2002 10/31/2007 10/31/2007 10/22/2003 03/22/2006 03/22/2006 03/27/2008 SUSQUEHANNA

- UNIT 1 TRM / LOES-6 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT1 TRM / LOES-6 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.4 B 3.5 B 3.6 B 3.7 Pages TRM / B 3.3-17e and TRM / B 3.3-17f Pages TRM / B 3.3-18 and TRM / B 3.3-19 Page TRM / B 3.3-20 Page TRM / B 3.3-2 1 Pages TRM / B 3.3-22 and TRM/IB 3.3-23 REACTOR COOLANT SYSTEM BASES Page B 3.4-1 Pages TRM / B 3.4-2 and TRM I B 3.4-3 Pages TRM / B 3.4-4 and TRM / B 3.4-4a Page TRM /B 3.4-5 Page B 3.4-6 Pages TRM / B 3.4-7 and TRM / B 3.4-8 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 Pages TRM / B 3.5-3 through TRM / B 3.5-5 CONTAINMENT BASES Page TRM / B 3.6-1 Page TRM / B 3.6-2 Page B 3.6-3 Page TRM / B 3.6-4 Page TRM / B 3.6-5 Page TRM / B 3.6-6 Pages TRM / B.3.6-7 through TRM / B 3.6-11 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Page TRM / B 3.7-3 Page TRM / B 3.7-3a Page TRM / B 3.7-4 Page TRM / B 3.7-5 Page TRM / B 3.7-6 Pages TRM / B 3.7-7 and TRM / B 3.7-7a Page TRM / B 3.7-8 Page TRM / B 3.7-9 Page TRM / B 3.7-10 Page TRM I B 3.7-I0a Page TRM / B 3.7-11 Page TRM / B 3.7-1 a Pages TRM / B 3.7-12 and TRM / B 3.7-13 Pages TRM / B 3.7-14 and TRM / B 3.7-14a 03/22/2006 08/03/2010 10/22/2003 05/16/2003 04/07/2009 08/31/1998 04/01/2009 10/31/2007 10/15/1999 08/31/1998 04/25/.2013 08/31/1998 10/31/2007 07/26/2001 02/01/1999 08/31/1998 03/27/2008 04/04/2007 12/03/2004 12/31/2002 08/31/1998 06/1 0/2010 12/27/2007 03/31/2006 08/02/1999 03/31/2006 08/02/1999 05/29/2013 04/11/2014 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 09/25/2012 SUSQUEHANNA - UNIT I TRM / LOES-7 EFFECTIVE DATE 10/07/2015 TRM / LOES-7

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM / B 3.7-14b Pages TRM / B 3.7-15 and TRM / B 3.7-16 Pages B 3.7-17 through B 3.7-20 Page TRM / B 3.7-21 Pages TRM / B 3.7-21a through TRM / B 3.7-21d Pages TRM / B 3.7-21e through TRM / B 3.7-21g Page TRM / B 3.7-22 and TRM / B 3.7-23 Page TRM / B 3.7-24 Page TRM / B 3.7-25 Pages TRM / B 3.7-26 through TRM / B 3.7-28 Pages TRM / B 3.7-29 and TRM / B 3.7-30 Page TRM / B 3.7-30a Page TRM / B 3.7-30b Page TRM / B 3.7-31 Page TRM / B 3.7-32 Page TRM / B 3.7-33 Page TRM / B 3.7-34 Page TRM / B 3.7-35 Pages TRM / B 3.7-36 through TRM / B 3.7-39 Page TRM / B 3.7-40 ELECTRICAL POWER BASES Page TRM / B 3.8-1 Page TRM 1 B 3.8-2 Page TRM / B 3.8-2a Page TRM / B 3.8-3 Page TRM / B 3.8-3a Page TRM / B 3.8-4 Page TRM / B 3.8-4a Page B 3.8-5 Pages TRM / B 3.8-6 through TRM / B 3.8-15 Page TRM / B 3.8-16 Page TRM / B 3.8-17 Pages TRM / B 3.8-17a and TRM / B 3.8-17b Pages TRM / B 3.8-18 through TRM / B 3.8-20 Pages TRM / B] 3.8-21 and TRM / B] 3.8-22 Page TRM / B] 3.8-23 Page TRM / B] 3.8-24 REFUELING OPERATIONS BASES Pages B 3.9-1 through B] 3.9-7 11/24/2011 02/01/1999 08/31/1998 05/29/2013 05/24/2012 05/29/2013 01/30/2008 10/05/2006 01/21/2014 10/05/2006 06/07/2007 10/05/2006 01/21/2014 11/30/2011 03/09/2001 04/15/2003 12/03/2004 07/05/2000 04101/2009 04/08/2010 04/02/2002 01/28/2005 03/01/20.10 04/02/2002 04/02/2002 09/03/2004 04/02/2002 08/31/1998 04/02/2002 11/07/2013 11/30/2011 11/30/2011 05/29/2013 05/28/2009 05/29/2013 05/28/2009 08/31/1998 B 3.8 B.3.9 SUSQUEHANNA

- UNIT I TRM / LOES-8 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - UNIT 1 TRM / LOES-8 EFFECTIVE DATE 10/07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 83 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.10 MISCELLANEOUS BASES Page B 3.10-1 Pages TRM / B 3.10-2 and TRM / B 3.10-3 Pages TRM / B 3.10-4 and TRM / B 3.10-5 Page TRM /B 3.10-6 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B 3.11-1 through B 3.11-9 Page TRM /B 3.11-10 Pages TRM/B 3.11-11 and TRM/B 3.11-11a Pages TRM/B 3.11-12 and TRM/B 3.11-13 Page TRM / B 3.11-14 Page TRM / B3.11-15 Pages B] 3.11-16 through B] 3.11-19 Page TRM/B[]3.11-20 Page TRM/ []3.11-20a Page TRM/B3.11-21 Pages TRM / B] 3.11-22 and TRM / B] 3.11-23 Pages TRM / B] 3.11-23a and TRM / B] 3.11-23b Pages TRM / B] 3.11-24 and TRM / B] 3.11-25 Pages B] 3.11-26 and B] 3.11-27 Page TRM/B[]3.11-28 Page TRM / B] 3.11-29 Pages TRM / B] 3.11-30 and TRM / B] 3.11-31 Page TRM / B] 3.11-32 Page TRM / [3.11-33 Pages B] 3.11-34 and B] 3.1 1-35 Page TRM / B] 3.11-36 B.3.12 LOADS CONTROL PROGRAM BASES Page TRM / B] 3.12-1 Page TRM / B] 3.12-2 Page TRM / B] 3.12-3 08/31/1998 03/22/2006 08/23/1999 03/27/2008 08/30/1998 02/01/1999 04/07/2000 02/01/1999 12/03/2004 02/01/1999 08/30/1998 04/02/2002 04/02/2002 05/13/2005 11/14/2006 06/18/2013 01/21/2004 08/30/1998 11/30/2005 02/19/2015 05/29/2013 08/30/1998 06/30/2010 08/30/1998 02/12/1999 09/19/2007 11/29/2010 02/05/1999 TRM1 text LOES I10/7/2015 SUSQUEHANNA-UNIT1 TRM / LOES-9 SUSQEHANA UNT I RM LOS-9EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 3.3 Instrumentation 3.3.4 TRM Post-Accident Monitoring Instrumentation TRO 3.3.4 The TRM post-accident monitoring instrumentation channels shown in Table 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.4-1 ACTIONS NiOTES.

1. Separate condition entry is allowed for each Function.
2. The provisions of TRO 3.0.6 are not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Enter the Condition referenced Immediately channel inoperable, in Table 3.3.4-1 for the channel.

B.

As required by Required B.1 Initiate the preplanned 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Action A.1 and referenced alternate method of monitoring in Table 3.3.4-1.

the appropriate parameter(s).

AND B.2 Restore the required channel 7 days / 30 days (*

to OPERABLE status.

C.

As required by Required C.1 Restore the required 30 days Action A.1 and referenced channel(s) to OPERABLE in Table 3.3.4-1 status.

D. As required by Required 0.1 Verify a minimum 14 of the Immediately Action A.1 and referenced in associated acoustic monitor Table 3.3.4-1 channels and 5 of the ADS AND SRV acoustic monitor channels are operable.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter (C) COMPLETION TIME for REQUIRED ACTION B.2 is extended from 7 to 30 days during construction activities associated with the replacement of SPING equipment with VERMS equipment.

SUSQUEHANNA - UNIT 1 TRM / 3.3-9 SUSQEHANA

- NITI TR

/ 33-9EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME OR D.2 Verify SRV tailpipe temperature indication and alarm are available for the tailpipe associated with the inoperable acoustic monitor.

OR D.3 Verify that the following alternate monitoring methods in TS Table 3.3.3.1-1 are OPERABLE:

Function 1 Function 2 Function 3 Function 10 AND D.4 Restore the required channel(s) to OPERABLE status.

Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter 30 days OR At next outage with containment entry, not to exceed the next refueling outage for in-accessible containment components.

SUSQUEHANNA-UNIT1 TRM / 3.3-9a SUSQEHANA UNT I RM 3.-9aEFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 8 3.3.4 TECHNICAL REQUIREMENT SURVEILLANCE NOTES---------------

1.

Refer to Table 3.3.4-1 to determine which TRSs apply for each Post Accident Monitoring Function.

2.

When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or an associated function is available.

SURVEILLANCE FREQUENCY TRS 3.3.4.1 Perform CHANNEL CHECK 31 days TRS 3.3.4.2 "Perform CHANNEL FuNcTIONAL TEST 92 days TRS 3.3.4.3 Perform a CHANNEL CALIBRATION. The Trip 24 months Setpoint shall be less than or equal to 0.25 of the full open nloise level.

TRS 3.3.4.4.

Perform CHANNEL CALIBRATION 24 months TRS 3.3.4.5 Perform CHANNEL CALIBRATION of the 92 days Primary Containment H2 and 02 Analyzers.

SUSQUEHANNA-UNIT1 TRM / 3.3-10 SUSQEHANA UNT 1 RM 3.-10EFFECTIVE DATE 10/31/2007

Rev. 8 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE

1. Suppression Chamber Air Temperature
2.

Main Steam Safety/Relief Valve Position Indicator (Acoustic Monitor)

3.

Reactor Building Vent Noble Gas Monitor

a. Mid Range(b)
b. High Range(b)
4.

Standby Gas Treatment System Vent Noble Gas Monitor 1,2 1,2 1/valve C

TRS 3.3.4.1 TRS 3.3.4.4 D

TRS 3.3.4.1 TRS 3.3.4.2 TRS 3.3.4.3 1,2, (a) 1,2, (a)

I 1

B TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4

a. Mid Range~b)
b. High Range(b) 1,2, (a) 1,2, (a) 1 I

B TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4

5.

Turbine Building Vent Noble Gas Monitor

a. Mid Range(b)
b. High Range(b) 1,2 1,2 1

1 B

TRS 3.3.4.1 TRS 3.3.4.4 B

TRS 3.3.4.1 TRS 3.3.4.4 (continued)

SUSQUEHANNA-UNIT1 TRM / 3.3-11 SUSQEHANA-UITITRM 3.-11EFFECTIVE DATE 10107/2015

Rev. 8 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 (continued)

TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE

6.

Standby Gas Treatment System Vent Stack Sampling System Flow

a.

Effluent System flow rate monitor(b) 1,2, (a)

IC TRS 3.3.4.1 TRS 3.3.4.4

b.

Sampler flow rate monitorcb) 1,2, (a)

IC TRS 3.3.4.1 TRS 3.3.4.4

7. Turbine Building Vent Stack Sampling System Flow
a.

Effluent System flow rate monitor(b) 1,2 1C TRS 3.3.4.1 TRS 3.3.4.4

b.

Sampler flow rate monitor(b)

TRS 3.3.4.1 1,2 1

C TRS 3.3.4.4

8. Containment H2 and 02 Analyzer(b) 1,2 2

C TRS 3.3.4.1 TRS 3.3.4.5 (a)

(b)

When moving irradiated fuel in the secondary containment.

TRO 3.0.4.c is applicable.

SUSQUEHANNA-UNIT 1 TRM / 3.3-1 la SUSQEHANA

-UNI I TM

/3.3-IaEFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The primary purpose of the TRM PAM instrumentation is to display plant variables that provide information required by the control room operators during accident situations. The OPERABILITY of the TRM PAM instrumentation ensures that the identified information is available on selected plant parameters to monitor and assess important variables following an accident. This capability is consistent with the recommendations of Regulatory Guide 1.97 Revision 2, "Instrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant Conditions During and following an Accident," NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations" and NEDO-33160-A Revision 1, "Regulatory Relaxation For The Post Accident SRV Position Indication System" (Reference 6). It should be noted that the Technical Specifications LCO 3.3.3.1 contains all Category 1, non-type A instruments and Regulatory Guide 1.97 Type A instrument (References 1 and 2). This TRO requires instruments outside of these criteria.

Table 3.3.4-1 identifies the following required Functions. Suppression Chamber Air Temperature provides a post accident indication of problems with the primary containment pressure suppression system. The Suppression Chamber Air Temperature loops are comprised of the following instruments for the purpose of this TRM. The recorders are the primary method of indication used by the operator during an accident; therefore, the PAM specification deals specifically with this portion of the instrument.

LOOP A LOOP B

  • TE-15703 TE-1 5725
  • TT-15703 TT-15725
  • TR-15795A TR-15795B Main Steam Safety/Relief Valve Position Indicators (Acoustic Monitors) provide indication when the valves are functioning. Alternate methods for monitoring SRV position include SRV Tailpipe Temperature and the following Functions from Technical Specification Table 3.3.3.1-1:

Suppression Chamber Water Level (Function 3)

Suppression Chamber Water Temperature (Function 10)

Reactor Vessel Water Level (Function 2)

Reactor Steam Dome Pressure (Function 1)

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.3-4 SUSQEHANA

-UNITI TM/B33-4EFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The required channels for REACTOR BUILDING VENT Noble Gas Monitor, (continued)

Standby Gas Treatment System Vent Noble Gas Monitor, and Turbine Building Vent Noble Gas Monitor provide information regarding the release of radioactive materials to allow for early indication of the need to initiate action necessary to protect the public and for an estimate of the magnitude of any impending threat. For the Noble Gas Monitors the only required channels are the mid range and high range.

The drywell and suppression chamber hydrogen and oxygen concentrations gas analyzers monitor hydrogen and oxygen concentration to detect combustible gas levels in primary containment. The analyzers are capable of determining hydrogen concentration in the range of 0 to 30% by volume and oxygen concentration in the range of 0 to 10% by volume, and each provide control room indication and output to a control room recorder. Each gas analyzer must be capable of sampling either the drywell or the suppression chamber. The recorders are the primary method of indication available for use by the operator during an accident, therefore the PAM Specification deals specifically with this portion of the instrument channel. The gas analyzer piping is provided with heat tracing to reduce the buildup of condensation in the system. H202 Analyzers can be considered OPERABLE for accident monitoring for up to 100 days with their heat tracing INOPERABLE.

ACTIONS The Actions are defined to ensure proper corrective measures are taken in response to the inoperable components.

During construction activities that replace existing SPING equipment with new VERMS equipment, the Vent Noble Gas Monitor for each release path is anticipated to be inoperable for longer than 7 days. Restoration completion time to return the affected channel to OPERABLE status to support construction activities is extended to 30 days. This condition is compensated for by the enhanced Preplanned Alternate Monitoring Plan per REQUIRED ACTION B.1.

(continued)

SUSQUEHANNA-UNIT1 TRM / B 3.3-5 SUSQEHANA

-UNI I RM

/B 33-5EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES ACTIONS (continued)

Action 0 requirements were determined by balancing the safety significance of the system with the impact of the actions on the operating unit. The loss of the acoustic monitors is not safety significant providing the diverse and redundant alternate methods of determining SRV position are available.

System components in the control room are restorable within 30 days without unit operation impact. Components located in containment require a unit shutdown to gain access to individual components. The sYstem channels shall be restored to operable condition at earliest opportunity.

Noble gas monitoring may be interrupted for up to 30 minutes to perform particulate filter/iodine cartridge changeout required by TRM Table 3.11.2-1 without entering the TRO ACTIONS.

Components of alternate SRV position systems may be taken inoperable for routine surveillances and periodic maintenance providing the appropriate LCO requirements are met during this action statement. Tailpipe temperature is the direct process monitoring, alternate method and is not covered by Technical Specification LCO's as are the other alternative methods.

TRS The Technical Requirement Surveillances (TRS) are modified by two Notes.

Note 1 states that the TRSs for each Post Accident Monitoring instrumentation Function are located in the SR column of Table 3.3.4-1.

Note 2 modifies the Surveillances to indicate that when a channel is placed in a inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or associated Function are available. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken.

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.3-6 SUSQEHANA

-UNI I RM

/B 33-6EFFECTIVE DATE 06/30/2010

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS (continued)

The alternate means of monitoring the parameter or the associated function are:

Parameter Alternate Means/Associated Function Suppression Chamber Air Temperature Main Steam Safety/Relief Valve Position Indicator Containment H2 and 02 Analyzer One channel of Suppression Chamber Air Temperature Suppression Pool level Suppression Pool Temperature RPV level RPV pressure SRV Tailpipe Temperature One channel of Containment H2 and 02 The TRSs are defined to be performed at the specified Frequency to ensure that the TRM PAM Function is maintained OPERABLE.

TRS 3.3.4.1 Performance of the CHANNEL CHECK once every 31 days ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel against a similar parameter on other-channels. It is based on the assumption that (continued)

SUSQUEHANNA-UNiT1 TRM / B 3.3-7 SUSQEHANA

-UNI I RM

/B 33-7EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS TRS 3.3.4.1 (continued) instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.

Agreement criteria, which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit and does not necessarily indicate the channel is inoperable.

REFERENCES

1.

Regulatory Guide 1.97 Revision 2, "Instrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident."

2.

NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations."

3.

Technical Specification Amendment No. 100 to License No. NPF-22 for failed Unit 2 "5" acoustic monitor.

4.

Technical Specification Amendment No. 169 to License No. NPF-14 for failed Unit 1 "5" acoustic monitor.

5.

Proposed amendment No. 183 to License No. NPF-22 failed Unit 2 "J" acoustic monitor.

6.

NEDO-33160-A, Revision 1, "Regulatory Relaxation For The Post Accident SRV Position Indication System," dated October 2006.

7.

NRC letter, "Final Safety Evaluation For Boiling Water Reactor Owners' Group (BWROG) Topical Report (TR) NEDO-33160, Regulatory Relaxation For The Post Accident SRV [Safety Relief Valve] Position Indication System (TAC No. MC5446)," dated September 26, 2006.

SUSQUEHANNA-UNIT1 TRM / B 3.3-8 SUSQEHANA

-UNI I RM

/B 33-8EFFECTIVE DATE 06/30/2010

Oct.

15, 2015 Page 1

of 2

MANIJAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2015-41310 USER INFORMATION:

GERLACH*ROSEY N EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY N 10/15/2 015 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TRM2 TECHNICAL REQUIREMENTS MANUAL UNIT 2 REMOVE MANUAL TABLE OF CONTENTS DATE: 10/05/2015 ADD MANUAL TABLE OF CONTENTS DATE: 10/14/2015 CATEGORY:

DOCUMENTS TYPE: TRM2

Oct.

15, 2015 Page 2

of 2

ID:

TEXT 3.3.4 ADD:

REV:

8 REMOVE:

REV: 7 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT B3.3.4 ADD:

REV:

5 REMOVE:

REV:4 CATEGORY:

DOCUMENTS TYPE: TRM2 ID:

TEXT LOES ADD:

REV:

86 REMOVE:

REV:85 ANJY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INB0X.

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 Table Of Contents Issue Date:

10/14/2 015 Procedure Name TEXT LOES

Title:

LIST OF EF:

Rev Issue Date 86 10/14/2015 F'ECTIVE SECTIONS Change ID Change Number TEXT TOC

Title:

24 04/28/2015 TABLE OF CONTENTS TEXT 1.1 0

11/19/2002

Title:

use AND APPLICATION DEFINITIONS TEXT 2.1 1

02/04/2005

Title:

PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS TEXT 2.2 11 01/31/2014

Title:

PLANT PROGRAMS AND SETPOINTS INSTRUMENT TRIP SETPOINT TABLE TEXT 3.0

Title:

6 03/05/2015 APPLICABILITY TECHNICAL REQUIREMENT FOR OPERATION (TRO)

APPLICABILITY TEXT 3.1.1

-1 11/09/2007

Title:

REACTIVITY CONTROL SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT 3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3 4

05/14/2009

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT 3.2.1 11 04/28/2015

Title:

CORE OPERATING LIMITS CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 15 Report Date: 10/15/15 Page !

of 15 Report Date: 10/15/15

SSES MANTJAI~

Manual Name :

TRM2 ii*Manual

Title:

TECHNICAL REQUIREMENTS MANUJAL UNIT 2 TEXT 3,3.1 0

11/19/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUM4ENTATION TEXT 3,3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3,3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4

Title:

INSTRUMENTATION 8

10/14/2015 TRM POST-ACCIDENT MONITORING INSTRUMENTATION LDCN 4553 TEXT 3.3.5 0

11/19/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3,3.6 4

04/29/2014

Title:

INSTRUMENTATION TEN ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 1

11/09/2007

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3,3.8 1

10/22/2003

Title:

INSTRUMENTATION TEN RPS INSTRUMENTATION TEXT 3.3.9

Title:

INSTRUMENTATION TEXT 3.3.10

Title:

INSTRUMENTATION 3

05/14/2009 LPRM UPSCALE ALARM INSTRUMENTATION 1

12/14/2004 REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015

Title:

WATER MONITORING INSTRUMENTATION Page 2 of 15 Report Date: 10/15/15 Page !

of 15 Report Date: 10/15/15

SSES MANUJAI Manual Names TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.4.1

Title:

REACTOR TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.5.1 1

04/26/2006 COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY 1

04/16/2009 COOLANT SYSTEM STRUCTURAL INTEGRITY 1*

11/09/2007 COOLANT SYSTEM REACTOR COOLANT SYSTEM (RCS) 2 05/14/2009 COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 1

04/26/2006 COOLANT SYSTEM REACTOR VESSEL MATERIALS 1

04/25/2013 RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION 1

02/04/2005

Title:

ECCS AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

ECCS AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/19/2002

Title:

ECCS AND RCIC LONG TERN NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/19/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/19/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page 3~

of 15 Report Date: 10/15/15 Page of 15 Report Date: 10/15/15

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.6.4 0

11/19/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1

Title:

PLANT TEXT 3.7.2 Title : PLANT TEXT 3.7.3,1 Title : PLANT TEXT 3.7.3.2 Title : PLANT

  • TEXT 3.7.3,3 Title : PLANT TEXT 3.7.3.4

Title:

PLANT TEXT 3.7.3.5

Title:

PLANT TEXT 3.7.3.6 Title : PLANT TEXT 3.7.3.7 Title : PLANT TEXT 3.7.3.8

Title:

PLANT TEXT 3.7.4

Title:

PLANT 0

11/19/2002 SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN 0

11/19/2002 SYSTEMS ULTIMATE HEAT SINK CURS) AND GROUND WATER LEVEL 2

04/16/2009 SYSTEMS FIRE SUPPRESSION WATER sUPPLY SYSTEM 3

04/16/2009 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 3

04/16/2009 SYSTEMS C02 SYSTEMS 2

04/16/2009 SYSTEMS HALON SYSTEMS 2

04/16/2009 SYSTEMS FIRE HOSE STATIONS 2

04/16/2009 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 1

04/26/2006 SYSTEMS FIRE RATED ASSEMBLIES 11 09/27/2012 SYSTEMS FIRE DETECTION INSTRUMENTATION 1

04/26/2006 SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 15 Report Date: 10/15/15 Page 4 of i_55 Report Date: 10/15/15

SSES MANUJAI

    • I Manual Name :

TRN2

... Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER 0FFGAS PRETREATMENT LOGARITHMIC RADIATION S

  • MONITORING INSTRUMENTATION
TEXT 3.7.8 9

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 1

08/28/2006

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 2

04/29/2014

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.1 1

10/02/2009

Title:

PLANT SYSTEMS TEXT 3.8.1 3

06/20/2012

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THEEMAJL OVERLOAD PROTECTION -

CONTINUOUS

£ TEXT 3.8.2.2 2

12/14/2004 WTitle: ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION AUTOMATIC Page !

of i_55 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRM2 i*

Manual

Title:

TECHNICAL REQUIREMENTS MANAL UNIT 2 TEXT 3.8,3 Title 2 ELECTRICAL TEXT 3.8,4 Title 2, ELECTRICAL TEXT 3.8,5 Title,, ELECTRICAL TEXT 3.8,6 Title 2 ELECTRICAL TEXT 3.8,7 2

06/20/2012 POWER DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 1

02/04/2005 POWER 24 VDC ELECTRICAL SUBSYSTEM 1

11/14/2013 POWER DEGRADED VOLTAGE PROTECTION 2

12/14/2006 POWER EMERGENCY SWITCHGEAR ROOM COOLING 2

10/22/2009 Title 2 BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9,1 0

11/19/2002 Title 2 REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/19/2002 Title 2 REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/19/2002 Title 2 REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006 Title 2 MISCELLANEOUS SEALED SOURCE CONTAMINATION TEXT 3.10.2 1

04/09/2007 Title 2 MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.11.1.1 1

04/26/2006 Title 2 RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION Page 6 of 15 Report Date: 10/15/15 Page h of 15 Report Date: 10/15/15

SSES MANTJI*

Manual Name :

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.1.2

Title:

RADIOACTIVE TEXT 3.11.1.3

Title:

RADIOACTIVE TEXT 3.11.1.4

Title:

RADIOACTIVE TEXT 3.11.1.5

Title:

RADIOACTIVE TEXT 3.11.2.1

Title:

RADIOACTIVE TEXT 3.11.2.2

Title:

RADIOACTIVE TEXT 3.11.2.3

Title:

RADIOAdTIVE FORM TEXT 3.11.2.4

Title:

RADIOACTIVE TEXT 3.11.2.5

Title:

RADIOACTIVE TEXT 3.11.2.6

Title:

RADIOACTIVE TEXT 3.11.3

Title:

RADIOACTIVE TEXT 3.11.4.1

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1

04/26/2006 LIQUID EFFLUENTS DOSE 1

04/26/2006 LIQUID WASTE TREATMENT SYSTEM 2

10/09/2012 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 3

03/05/2015 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 3

04/26/2006 DOSE RATE 1

04/26/2006 DOSE NOBLE GASES 1

04/26/2006 DOSE

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE 0

11/19/2002 GASEOUS RADWASTE TREATMENT SYSTEM 4

07/03/2013 VENTILATION EXHAUST TREATMENT SYSTEM 5

03/05/2015 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION 1

04/26/2006 TOTAL DOSE 4

03/05/2015 MONITORING PROGRAM Page 2 of 15 Report Date: 10/15/15 Page 7 of 15 Report Date: 10/15/15

SSES MANUAL Manual Name :

TRM2

  • Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3

Title:

LOADS CONTROL PROGRAM 0

11/19/2002 LIGHT LOADS REQUIREMENTS TEXT 4.1

Title:

TEXT 4.2

Title:

TEXT 4.3

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

TEXT 4.7

Title:

0 09/27/2003 ADMINISTRATIVE CONTROLS ORGANIZATION ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

09/27/2003 CONTROLS REPORTABLE EVENT ACTION 0

09/27/2003 CONTROLS SAFETY LIMIT VIOLATION 1

12/18/2008 CONTROLS PROCEDURES & PROGRAMS 0

09/27/2003 CONTROLS REPORTING REQUIREMENTS 0

09/27/2003 CONTROLS RADIATION PROTECTION PROGRAM 0

09/27/2003 CONTROLS TRAINING Page 8 of 15 Report Date: 10/15/15 Page 8 of 15 Report Date: 10/15/15

SSES M.ANUJAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.0 6

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION CTRO)

APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEM BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT B3.1.3 3

04/10/2007

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION A.

AND CHECK VALVE TEXT B3.2.1

Title:

CORE OPERATING L TEXT B3.3.1

Title:

INSTRUMENTATION TEXT B3.3.2

Title:

INSTRUMENTATION TEXT B3.3.3

Title:

INSTRUMENTATION TEXT B3.3.4

Title:

INSTRUMENTATION TEXT B3.3.5

Title:

INSTRUMENTATION TEXT B3.3.6

Title:

INSTRUMENTATION

,IMITS 0

11/19/2002 BASES CORE OPERATING LIMITS REPORT (COLR) 1 01/31/2014 BASES RADIATION MONITORING INSTRUM]ENTATION 2

03/31/2011 BASES SEISMIC MONITORING INSTRUMENTATION 2

11/09/2007 BASES METEOROLOGICAL MONITORING INSTRUMENTATION-5 10/14/2015 BASES TEN POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION LDCN 2

11/09/2007 BASES THIS PAGE INTENTIONALLY LEFT BLANK 5

01/31/2014 BASES TEN ISOLATION ACTUATION INSTRUMENTATION 4553 Page ~

of 15 Report Date: 10/15/15 Page 9 of i_55 Report Date: 10/15/15

SSES MANUJAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MAMATJAL UNIT 2 TEXT B3.3.7

Title:

INSTRUMENTATION 1

11/09/2007 BASES MAIN TURBINE 0VERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22/2003

Title:

INSTRUMENTATION BASES TRM RPS INSTRUMENTATION TEXT B3.3.9

Title:

INSTRUMENTATION 3

05/.14/2009 BASES. LPRM UPSCALE ALARM INSTRUMENTATION TEXT B3.3.10 3

02/22/2012

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS TEXT B3.3.11 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.3.12 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2

Title:

REACTOR COOLANT TEXT B3.4.3

Title:

REACTOR COOLANT TEXT B3.4.4

Title:

REACTOR COOLANT TEXT B3.4.5

Title:

REACTOR COOLANT TEXT B3.4.6 1

04/16/2009 SYSTEM BASES STRUCTURAL INTEGRITY 1

11/09/2007 SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR 0

11/19/2002 SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 0

11/19/2002 SYSTEM BASESREACTOR VESSEL MATERIALS 1

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION Page i~.

of 15 Report Date: 10/15/15 Page i0 of 15 Report Date: 10/15/15

SSES MANUAL q

Manual Name :

TRM2 SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.5.1

Title:

EGGS AND RCIG 0

11/19/2002 BASES ADS MANUAL INHIBIT TEXT B3.5.2 1

11/09/2007

Title:

EGGS AND RCIG BASES EGGS AND RGIG SYSTEM MONITORING INSTRUMENTATION TEXT B3.5.3 1

11/09/2007

Title:

EGGS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION GRAMBER-TO-DRYWELL VACUUJMBREAKER POSITION INDICATION TEXT B3.6.3 1

04/19/2007

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1

Title:

PLANT TEXT B3.7.2

Title:

PLANT TEXT B3.7.3.1

Title:

PLANT TEXT B3.7.3.2

Title:

PLANT TEXT B3.7.3.3

Title:

PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0

11/19/2002 EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN) 0 11/19/2002 ULTIMATE HEAT SINK (URS)

GROUND WATER LEVEL 3

06/15/2010 FIRE SUPPRESSION WATER SUPPLY SYSTEM 2

04/26/2006 SPRAY AND SPRINKLER SYSTEMS 0

11/19/2002 C02 SYSTEMS Page 12.

of 15 Report Date: 10/15/15 Page i!l of 15 Report Date: 10/15/15

SSES MANUAL Manual Name:

TRM2 SManual Title-TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.3.4

Title:

- PLANT TEXT B3.7.3.5 Title : PLANT TEXT B3.7.3.6

Title:

PLANT TEXT B3.7.3.7 Title : PLANT TEXT B3.7.3.8

Title:

PLANT TEXT B3.7.4 Title : PLANT TEXT B3.7.5.1 Title : PLANT TEXT B3.7.5.2 Title : PLANT TEXT B3.7.5.3 Title : PLANT TEXT B3.7.6 Title : PLANT 2

04/29/2014 HALON SYSTEMS SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 1

04/26/2006 FIRE HOSE STATIONS 1

04/26/2006 YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 FIRE RATED ASSEMBLIES 3

09/27/2012 FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SOLID RADWASTE SYSTEM 0

11/19/2002 MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/19/2002 MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002 LIQUID HOLDUP TANKS 4

06/04/2013 ESSW PUMPHOUSE VENTILATION 2

01/31/2008 TEXT B3.7.7

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFOAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION TEXT B3.7.8 4

Title:

PLANT SYSTEMS BASES SNUBBERS 01/31/2 014 Page 12 of 15 Report Date: 10/15/15 Page 1/2 of i_55 Report Date: 10/15/15

SSES MANUJAI a

i Manual Name:

TRJA2 W-Manual

Title:

TECHNJICAL REQUIREMENTS MAMAL UNIT 2 TEXT B3.7.9 2

12/08/2011

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE IDVAC TEXT B3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.7.11

Title:

STRUCTURAL TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL TEXT B3.8.5

Title:

ELECTRICAL TEXT B3.8.6

Title:

ELECTRICAL TEXT B3.8.7 2

04/14/2010 INTEGRITY 2

03/10/2010 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 1

09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

PROTECTION -

0 11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE 0

11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 1

11/14/2013 POWER BASES DEGRADED VOLTAGE PROTECTION 3

06/20/2012 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 2

06/04/2013 ACTIVITIES

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME Page 23.

of 15 Report Date: 10/15/15 Page 13 of 15 Report Date: 10/15/15

SSES MANTJAL Manual Name:

TRM2 SManual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COJYUIUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

Title:

MISCELLANEOUS BASES SEALED 11/19 /2 002 SOURCE CONTAMINATION TEXT B3.10.2 1

04/10/2007

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.11i.1.

Title:

RADIOACTIVE TEXT B3.11.1.2

Title:

RADIOACTIVE TEXT B3.11.1.3

Title:

RADIOACTIVE TEXT B3.11.1.4

Title:

RADIOACTIVE 0

11/19/2002 EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION 0

11/19/2002 EFFLUENTS BASES LIQUID EFFLUENTS DOSE 0

11/19/2002 EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM 0

11/19/2002 EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5 U

Title:

RADIOACTIVE EFFLUENTS BASES 11/19/2 002 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT B3.11.2.1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2

Title:

RADIOACTIVE EFFLUENTS 0

11/19/2002 BASES DOSE NOBLE GASES Page 14 of 15 Report Date: 10/15/15 Page 1__{4 of 15 Report Date: 10/15/15

SSES MAi*TA Q

Manual Name:*

TRM2 W:i Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM 0

BASES 11/19/2002 DOSE

IODINE, TRITIUM, AND RADIONUCLIDES IN TEXT B3.11.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT 33.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.12.1

Title:

LOADS CONTROL PROGRAM TEXT B3.12.2

Title:

LOADS CONTROL PROGRAM TEXT B3.12.3

Title:

LOADS CONTROL PROGRAM 5

.07/03/2013 BASES VENTILATION EXHAUST 1

01/27/2004 BASES RADIOACTIVE GASEOUS 0

11/19/2002 BASES TOTAL DOSE 5

03/05/2015 BASES MONITORING PROGRAM 0

11/19/2002 BASES LADUSE CENSUS TREATMENT SYSTEM EFFLUENT MONITORING 0

BASES 11/19/2 002 INTERLABORATORY COMPARISON PROGRAM 1

10/04/2007 BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL 1

12/03/2010 BASES HEAVY LOADS REQUIREMENTS 0

11/19/2002 BASES LIGHT LOADS REQUIREMENTS Page i~.

of 15 Report Date: 10/15/15 Page 15 of i__55 Report Date: 10/15/15

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LUST OF EFFEC TIVYE SECTIONS (TIECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC 1.0 2.0 3.0 TABLE OF CONTENTS USE AND APPLICATION Page TRM / 1.0-1 Page TRM 1 1.0-2 Page TRM 1/1.0-3 04/23/2015 08/31/1998 10/04/2002 08/31/1998 PL.ANT PROGRAMS Page 2.0-1 Pages TRM 1 2.0-2 and TRM 2.0-3 Page TRM I 2.0-4 Page TRM / 2.0-5 Page TRM / 2.0-6 Page TRM 1 2.0-7 Pages TRM /2.0-8 and TRM / 2.0-9 Page TRM / 2.0-10 Page TRM / 2.0-11 Page TRM / 2.0-12 Pages TRM /2.0-13 and TRM / 2.0-14 Page TRM /2.0-15 APPLICABILITY Pages TRM / 3.0-1 and TRM, / 3.0-2 Page TRM /13.0-3, Page TRM I 3.0-4 REACTIVITY cONTROL sYSTEMS Page TRMI /3.i1-1 Pages TRM /]3.1-2 through TRM / 3.1-5

.Page-TRM / 3.1-6 Page-TRM 1 31-7 Page TRM / 3.1-8 S-Pages TRM / 3.1-9 and TRM 1 3.1-9a "Page TRM /3.1-10

  • CORE OPERATING.LIMITS :REPORT

...Page TRM /3.2-1 Pages TRM / 3.2-2 through TRM /3.2-54 INSTRUMENTATION Pages TRM 1 3.3-1 through TRM / 3.3-3 Pages TRM / 3.3-4 and TRM /13.3-5 Page TRM / 3.3-6 Page TRM 3.3-7 Page 3.3-8 08/31 /1998

.... 01/28/2005 06/25/2002 01./2.1/2014

  • ,04,/15/2009 05/15/2008 01/07/2011 02/02/2010 11/15/2004 04/15/2009 11/15/2004 11/15/2005 3.1 02/19/2015 03/15/2002 02/19/2015 10/31/2007 08/31/1995 03/27/2007 04/15/2009 03/27/2007 02/18/1999 02/18/1999 08/31/1998 04/21/2015 07/16/1999 10/31/2007 03/10/2011 10/31/2007 08/31/1998 3.2 3.3 SUSQUEHANNA - UNIT 2 TRM 1,/OES-1 SUSQEHANA UNT 2 RM LOS-1EFFECTIVE DATE 10/07/2015

I7 ii O

I SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Page TRM / 3.3-9 Page T]RM / 3.3-9a Page TRM /3.3-10 Page TRM / 3.3-11 Page TRM / 3.3-lia Page "TRM / 3.3-12 Page TRM / 3.3-13 Page TRM 1 3.3-14 Page TRM / 3.3-15 Page TRM / 3.3-16 Page TRM / 3.3-17 Page TRM I 3.3-18 Pages TRM 1 3.3-19 and TRM 13.3-20 Page TRM / 3.3-21 Page TRM / 3.3-21a Pages T]RM /3.3-21b through TRM I 3.3-21d Page TRM /3.3-22 Pages TRM / 3.3-23 and TRM / 3.3-24 Page TRM /3.3-25 Page TRM /3.3-26 Page TRM / 3.3-27 3.4 REACTOR COOLANT SYSTEM Page TRM / 3.4-1 Pages 3.4-2 through 3.4-5 Pages TRM / 3.4-6 through TRM t 3.4-8 Page 3.4-9 Page 3.4-10 Page 3.4-11 Page TRM / 3.4-12 Page TRM / 3.4-13 Page TRM / 3.4-14 3.5 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 Pages 3.5-2 and 3.5-3 Page TRM / 3.5-4 Pages 3.5-5 through 3.5-7 3.6 CONTAINMENT Pages 3.6-1 and 3.6-2 Pages TRM,/3.6-3 and TRM / 3.6-3a Page 3.6-4 Page TRM / 3.6-5 Page 3.6-6 Pages TRM / 3.6-7 through TRM I 3.8-9 Effective Date 10/0"7/2015 06/3012010 10/3112007 10/07/2015 101071/2015 03/30/2001 01,/0712011 12/14/1998 04111/2014 01/07/2011 06114/2002 10/311/2007 10/22/2003 04115/2009 11,/15/2004 03/27,/2007 12/03/2004 05/16/2003 10,/22/2003 02119/2015 "04t07,/2009 03/31/2006 10/23/1998 04/01/2009 08/31,/1998 10/31/2007 08/31/1998 04117/2009 03/31/12006 04/25/2013 01/28/2.005 08/31/1998 10/31/2007 08/31/1998 08/31/1998 04/16/2014 08/31/1998 01/07/2002 08/31/1998 12/31/2002 SUSQUEHANNA

- UNIT 2 TRM / LOES-2 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM / LEES-2 EFFECTIVE DATE 10107/2015

SUSQUEHANNA STEAM ELECTRIC STATION -Rev.

86 UIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.7 O_*,.

PLANT SYSTEMS Pages TRM I 3.7-1 and TRM I 3.7-2, Page 3.7--3 Page TRM 1 3.7-4 Page TRM 1 3.7-5 Pages TRM 1]3.7-6 through TRM 1 3.7-8 Pages TRM 1 3.7-9 and TRM / 3.7-10 Page TRM 1 3.7-i11 Page TRM 1 3.7-12 Page TRM !/3.7-13 Page TRM 1 3.7-14 Pages TRM / 3.7-15 and TRM / 3.7-16 Page TRM 1 3.7-17 Page TRM 1 3.7-18 Page TRM 1 3.7-19 Pages TRM 1 3.7-20 through TRM / 3.7-22 Page TRM / 3.7-23 Page TRM 13.7-24 Page TRM / 3.7-25 Page TRM /3.7-26 Page TRM 13.7-27 Pages TRM 1 3.7-28 through TRM /3.7-32a Page TRM / 3.7-33 Page TRM /3.7-34 Pages TRM 1 3.7-35 and TRM / 3.7-36 Page TRM 1 3.7-37 Page TRM /3.7-3.8 Page TRM / 3.7-39 Page TRM !/3.7-40 Pages TRM 1 3.7-40a through TRM / 3.7-40c Page TRM / 3.7-41 Page TRM / 3.7-42 Pages TRM / 3.7-43 Pages TRM 1 3.7-44 and TRM / 3.7-45 Page TRM /3.7-46 Page TRM / 3.7-47 Page TRM / 3.7-48 Page TRM ! 3.7-49 Page TRM / 3.7-50 Page TRM / 3.7-51 Page TRM / 3.7-52 Page TRM / 3.7-53 Page TRM /3.7-54 Page TRM /3.7-55 Page TRM /3.7-56 0712911999 08/31/i1998 03/31/2006 04/07/2009 08102/1999 04/07/2009 01/2112.000 08/0211999 04/07/2009 08/09/2005 08/0211999 04/07/2009 08/02/1 999 04/07/2009 08/02/1999 04/07/2009 03/31/2006 08/02/1999 09/25/2012 11/24/2011 09/25/2012 09/25/2012 03/31/2006 02/01/1999 02/19/2015 08/31/1998 03/31/2006 05/24/2012 05/24/2012 09104/2008 08/31/1998 02/19/2015 10/05/2006 06/07/2007 09/05/2012 06/07/2007 03/09/2001 08/16/2006 12/03/2004 04/15/2003 07/29/1999 04/01/2009 09/25/2009 04/01/2009 SUSQUEHANNA - UNIT 2 TRM /LOES-3 EFFECTiVE DATE 10/07/2015 SUSQUEHANNA - UNIT 2 TRM/LOES-3 EFFECTlVE DATE 10/07/2015

SUSQUEH-ANNA STEAM ELECTRIC STATION Rev. 86" LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.8 ELECTRICAL POWER Page TRM /3.8-1 Page TRM / 3.8-2 Pages TRM / 3.8-3 and TRM I 3.8-4 Pages TRM / 3.8-5 and TR 1 3.8-6 Pages TR

/ 3.8-7 through TRM / 3.8-10 Page TRM 1 3.,8-11 Page TRMJ]3..8-12 Page TRM /3.8-13 Page TRM 1 3.8-14 Page TRM / 3.8-15 Pages TRM /3.8-16 and TRM 1 3.8-17 Page 3.8-18 Page TRM / 3.8-19 Page TRM 1 3.8-20 Pages TRM / 3.8-21 and TRM /3.8-22 Page TRM / 3.8-23 Page TRM / 3.8-24 Page TRM 1 3.8-25 Pages TRM / 3.8-25a and TRM I 3.8-25b Page TRM / 3.8-26 Page TRM / 3.8-27 Page TRM 1 3.8-28 Page TRM 1 3.8-29 04/02/,2002 0112812005 06/11/2012 04/0212002 10/31/2007 0910312004 1210312004 06/1212012 0'8131/1998 01/28/2005 04/02/2002 021,0111999 04./0212.002 02101/'1999 06106/1999 1110,7/2013 11/30/2,011 06/11/2012 I1/1301201.1 05/28/2009 11/29/2006 05/28/2009 10120/2009 08/3111998 03/31/2006 08/30/1998 03/27/2 007 06/10/2010 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 3.11 MISCELLANEOUS Page TRM / 3.10-1 Pages 3.10-2 through 3.1.0-4 Pages TRM / 3.10-5 and TRM /3.10-6 Page TRM / 3.10-7 RADIOACTIVE EFFLUENTS Page TRM 1 3.11-1 Pages 3.11-2 through 3.11-3 Page TRM / 3.11-4 Page 3.11-5 Page TRM / 3.11-5 Pages 3.11-7 and TRM /3.11-8 Pages TRM / 3.11-9 and TRM / 3.11-10 Pages TRM / 3.11-11 and TRM / 3.11-12 103131/2006 08/31/1 998 03/31/2005 08/31/1998 03/31/2006 08/31/1998 10/09/2012 08/31/1998 SUSQUEHANNA-UNIT 2 TRM / LOES-4 EFFECTIVE DATE 10/07/2015 SUSQU*5*NNA - 'UNIT 2 TRM ! LOES-4 EFFE'CTI* DATE 10t07/2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 UIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM 1 3.11-13 Page TRM I 3.11-14 Pages 3.11-15 and 3.11-16 Page TRM 1 3.11-17 Page 3.11-18 Page TRM/]3.11-19 Pages TRM 1 3.11-20 and TRM / 3.11-21 Page TRM 1 3.1-22 Page TRM ]13.11-23 Page TRM 1 3.11-24 Page T']RM 13.11-25 Pages TRM 1 3.11-26 and T'IRM 1 3.11-27 Page TRM 1 3.11-,28 Page TRM / 3.11-29 Pages TRM 3.11--30 and TRM 1 3.11-31 Page TRM 1 3.11-32 Page TRM / 3.11-33 Page 3.11-34 Page TRW / 3.11-35 Pages TRM ] 3.11-36 through TRM 1 3.11-39 Page T]RM / 3.11-40 Pages TRM 1 3.11-41 through TRM 1 3.11-44 Page TRM 1 3.11-45 Page 3.11-46 Page TRW / 3.11-47 LOADS CONTROL PROGRAM Pages TRM 1 3.12-1 through TRM / 3.12-3 Page TRM 1 3.12-4 Page TRM / 3.12-5 ADMiNISTRAT]IVE CONTROLS Pages TRM / 4.0-1 through TRM / 4.0-3 Page TRM 1]4.0-4 Pages TRM / 4.0-5 through TRM / 4.0-8

_02/1 912015 1210312004 09/01/1998 03131/2006 08/3111998 08115/2,005 03/31/20106

'04/02/2002 11/14/2006 06/18/2,013 04/1212007 01/21/2004 09/08/'2009 1.2/03/2004 01121/2004 02/19/2015 03/31/2006 08/31/1998 03/31/2006 11/30/2005 02/19/2015

'08/31/1998 03/31/2006 08/31/1998 03/31/2006 02/05/1999 03/14/2008 02/05/1999 08131/1998 12/11/2008 08/.31/1998 3.12 4.0 SUSQUEHANNA - UNiT 2 TRM / 'LOES-5 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA - 'UNlT 2 TRM / LOES-5 EFFECTIVE DATE 10107t2015

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LIST OF EFFECTIVE SECiTIONS (TECHNICAL REQUIREMENTS MANUAL)

I.

Section Tlitle 8 3.0 APPUCAB~iLITY BASES Pages TRM 1 B 3.0-1 through TRM I B 3.0-3 Page TRM I B 3.0-4 Pages TRM I B 3.0-4a and TRM 1 B 3.O-4b Page -TRM 1 B 3.0-5 Pages T]RM / B 3.0-6 and TRM I B 3.0-7 Pages TRM I B 3.0-8 through TRM I1B 3.0-10 Pages TRM / B 3.0-11 and TRM / B 3.0-12 Pages TRM I B 3.0-13 through TRM I B 3.0-15 B 3.1 REACTIV*IIY CONTROL SYSTEMS BASES Page TRM I B 3.1-1 Page TRM I B 3.1-2 Page TRM /B 3.1-3 Page B 3.1-4 Pages TRM 1 B 3.1-5 through TRM /8B3.1-7 Page TRM I B 3.1-8 B 3.2 CORE OPERATING UMITS BASES Page B 3.2-1 B 3.3 INSTRUMENTATION BASES Page TRM I B 3.3-1 Page TRM I B 3.3-2 Page TRM I B-3.3-2a Pages T RM 1 B 3.3-3 and TRM / B 3.3-3a Page TRM /8B 3.3-4 Pages TRM / B 3.3-5 through TRM / B 3.3-7 Page TRM 1 B 3.3-8 Page TRM 18B3.3-9 Page TRM /8B3.3-10 Page TRM 18B3.3-11 Pages TRM /8 3.3-12 and TRM /8B3.3-13 Page TRM /8B3.3-14 Page TRM ! B 3.3-14a Page TRM /8 3.3-14b Pages TRM / B 3.3-15 through TRM ! B 3.3-17 Pages TRM I B 3.3-18 and TRM /8B3.3-19 Pages TRM I B 3.3-19a and TRM /8B 3.3-19Sb Page TRM /8B3.3-19Sc Effective Date 08/31/1998 02119/2015 02/19/2015 02/1912015

'06/1 2/2012 08/31/1998 03/1512002 02/19/2015 07/13/1999 0411612014 10/31/2007 08/31/1598 03/27/2007 02/1 811999 05/31]1 998 01/21/2014 03/10/2011 10/31/2007 10/31/2007 06/30/2010 10/07/2015 06/30/2010 10/31/2007 01/07/2011 02/21/2014 01/07./2,011 06/25/2002 10/31/2007 06/14/2002 10/22/2003 03/27/2007 03/27/2007 04/17/2009 SUSQUEHANNA - UNIT 2 TRM I LOES-6 SUSQEHANA-UNI 2 RM LOS-6EFFECTIVE DATE 10/07/2,01!5

SUSQUEHANNA STEAM ELECTRIC STATiON Rev. 86 LIST OFEFFECTIVSECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title B 3.4 B 3.5 Pages TRM 1 B 3.3-19d and TRM I B 3.3-19e Page TRM I B 3.3-2,0 Page TRM I B 3.3-21 Page TR I B 3.3-22 Page TRM I B 3.3-23 Pages TRM I B 3.3-24 and TRM I B 3.3-25 REACTOR COOLANT SYSTEM BASES Page TRM I B 3.4-1 Pages TRM 1 B 3.4-2 and TRM 1 B3.4-3 Pages TRM / B 3.4-4 and T3RM I B 3.4-4a Page TRM I B 3.4-5 Page B 3.4-6 Page TRM / B 3.4-7 ECCS AND RC1C BASES Pages B 3.5-1 and B 3.5-2 Pages TRM ] B 3.5-3 and TR I B 3.5-3a Page B 3.5-4 Page TRM / B 3.5-5 CONTAINMENT BASES Page TRM I B 3.6-1 Page TRM I B 3.6-2 Page B 3.6-3 Page TRM I B 3.8-4 Page TRM I B 3.6-5 Page TRM I B 3.6-6 Pages TRM /' B 3.6-7 through TRM / B 3.8-11 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Page TRM I B 3.7-3 Page TRM I B 3.7-3a Page TRM I B 3.7-4 Page TRM I B 3.7-5 Pages TRM / B 3.7-6 and TRM I B 3.7-6a Pages T'RM I B 3.7-7 and TRM I B 3.7-7a Page TRM / 'B 3,.7-8 Page TRM / B 3.7-9 Page TRM I B 3.7-10 8 3.6 Effective Date 03127/2007.

0211,612012 08103/2010 10/22/2003 05/1612003 04/07/2009 0813111998 0410112009 1013112007 10/15/1999 0813111998 04/25/2013 08/31/11998 10/31/2007 083/3111998 10/3112007 07/26./2001 02101/1999 08/31/]1998 0312912007 04/04/2007 12/03/2004 12/31/2002 08/3111998 06/1012010 12/27/2007 03/31/2006 08/0211999 03/31/2006 08/02/1 999 08/02/1.999.

04/11/2014 08/02/1999 B 3.7 SUSQUEHANNA -UNIT 2 TRM ] LOES-7 SUSQEHANA UNT 2 RM LOS-7EFFECTIVE DATE 10/07/2015

SUSQUEH-ANNA STEAM ELECTRIC STATION Re i*..

UST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL).=v. 86 Section Title Effective Date Pages TRM I B 3.7-10Ca through TRM I B 3.7-1 Ia Pages TRM I B 3.7-12 and TRM I B 3.7-13 Pages TRM I B 3.7-14 through TRM I B 3.7-14b Pages TRM I B 3.7-15 and TRM I B 3.7-16 Pages B 3.7-17 through B 3.7-2,0 Page TRM I B 3.7-21 Pages TRM I B 3.7-21a through TRM I B 3.7-21d Pages TRM I B 3.7-21e through TRM I B 3.7-21g Pages TRM I B 3.7-22 and TRM ! B 3.7-23 Page TRIM! B 3.7-24 Page TRM I B 3.7-25 Pages TRM I B 3.7-26 through TRM I B 3.7-29 Page TRM I B 3.7-30 Page TRM / B 3.7-30a Page TRM I B 3.7-30b Page TRM I B 3.7-31 Page TRM I B 3.7-32 Page TRM I B 3.7-33 Page TRM I B 3.7-34 Page TRM / B 3.7-35 Pages TRM I B 3.7-36 and TRM I B 3.7-37 Page TRM I B 3.7-38 Page TRM I B 3.7-39 Page TRM I B 3.7-40 ELECTRICAL POWER BASES Page TRM I B 3.8-1 Pages TRM I B 3.8-2 Page TRM I B 3.8-2a Pages TRM I B 3.8-3 and TRM I B 3.8-3a Page TRM I B 3.8-4 Page TRM I B 3.8-4a Page TRM I B 3.8-5 Pages TRM l B 3.8-6 through TRM I B 3.8-15 Page TRM 18B3.8-16 Page TRM / B 3.8-17 Page TRM I B 3.8-17a Page TRM / B 3.8-17b Pages TRM 18B3.8-18 through TRM I B 3.8-20 Pages TRM /8B3.8-21 and TRM / B 3.8-22 Page TRM I B 3.8-23 Page TRM 18B3.8-24 03/3112006 08/02/1999 0912512012 0210111999 08/3111998 05/29/2013 051.2412012 05/29/2013 01J30]2008 10105/2006 01/2112014 10/0512006 06/07/2007 10/05/2006 01121']2014 11/30/2011 03/09/2001 04/15/2003 12/0312004 07/]05/2.000 04/0112009 09/25/2009 04/01/2009 04/08/2010 04/02/2002 01/28/2005 03/01/2010 04/02/2002 09/03/2004 04/0212002 08/31/1998 04/02/2002 11/07/2013 11/30/2011 06111/2012 11/30/2011 05/29/2013 05/28/2009 05/29/2013

,05/2812009 B 3.8 e

SUSQUEHANNA - UNIT 2 TRM / LQES-8 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM / LOES-8 EFFECTIVE DATE 10f07/2015

J.

I 9 "

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 86 LISTOF EFFECTIV E SECTIONS (]TECHNIlCAL REQUIREMENTS MANUAL)

Section Title Effective Date B.3.9 REFUELING OPERATIONS BASES Pages B 3.9-i and B 3.9-2 Pages B 3.9-3 through B 3.9-7 B 3.10 MISCELLANEOUS BASES Page B 3.10-i Pages TRM I B 3.10-2 and TiRM I B 3.10-3 Pages TRM I B 3.10-4 and TRM I B 3.10-5 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B 3.11-1 through B 3.11-9 Page TRM I B 3.11-10 Pages T-IRM / B 3.1 1-11 and TRM / B 3.1 1-11a Pages TRM I B 3.11-12 and TRMI B 3.11-13 Page TRM I B 3.11-14 Page TRM 18B3.11-15 Pages B 3.11-16 through B 3.11-19 Pages TRM I B 3.11-20 and TRM I B 3.1 1-20a Page TRM / B 3.11-21 Pages TRM /B 3.11-'22 and TRM I B 3.11-23 Pages TRM /B 3.1 1-23a and TRM I B 3.1 1-23b Pages TRM /8B3.11-24 and TRMI]B 3.11-25 Pages B 3.11-26 through B 3.11-27 Page TRM / B 3.1 1-28 Page TRM I B 3.11-29 Pages TRM / B 3.11-30 and TRM l B 3.11-31 Page TRM 18B3.11-32 Page TRM /8B3.11-33 Pages TRM / B 3.11-34 and TRM I B 3.11-35 Page TRM 18B3.11-36 8.3.12 LOADS CONTROL PROGRAM BASES Page TRM I B 3.12-1 Page TRM /B 3.12-2 Page TRM I B 3.12-3 08131./1998 10/23/1998 08/31/1998 03/27/2007 08123/1999 08/31/1998 02/01/1999 04/07/2000 02101/1999 12/03/2004 02/01/1999 08/31/1998 04/0212002 05/13/2005 11114/2006 06/18/2013 01/21/2004 08/31/1998 11/30/2005 02/19/2015 05/29/2013 08/31/1998 06/30/2010 08/31/1998 02/1 2/1 999 09/19/2007 11/29/2010 02/05/1999 I.:?

TRM2 text LOES.doa 11JA3712015 SUSQUEHANNA - UNIT 2 TRM / LOES-9 EFFECTIVE DATE 10/07/2015 SUSQUEHANNA-UNIT2 TRM ] :LOES-9 EFFECTIVE DATE 10/07/2015

TRM Post Accident Monitoring instrumentation Rev. 8 3.3.4 3.3 'Instr'umentation 3.3.4 I]RM Post-Accident Monitoring Instrumentation TFRO 3.3.4 The TRM post-accidant monitoring instrumentation channels shown in T]able 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.4-i ACTi3ONS NOTES

1. Separate condition entry is allowed for each Function.
2. The provisions of TRO 3.05 are not applicable.

,CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Enter the Condition Immediately channel inoperable, referenced in Table 3.3.4-1 for the channel.

B3.

As required by Required 8].1 Initiate the preplanned 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Action A.1 and referenced alternate method of in Table 3.3.4-1.

monitoring the appropriate parameter(s).

AND 8.2 Restore the required channel 7 days / 30 days (*

to OPERABLE status.

C. As required by Required C.1 Restore the required 3D days Action A.1 and referenced channel(s) to OPERABLE in Table 3.3.4-1 status.

D.

As required by Required DA1 Verify a minimum 14 of the immediately Action A.1 and referenced associated acoustic monitor in Table 3.3.4-1 channels and 5 of the ADS AND SRV acoustic monitor channels are operable.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter (c),COMPLETION TIME for REQUIRED ACTION 8.2 is extended from 7 days to 30 days during construction activities associated with the replacement of SPING equipment with VERMS equipment.

SUSQUEHANNA-UNIT2 TRM / 3.3-9 SUSQEHANA

-UNIT2 TM 133-9EFFECTIVE DATE 10/0712015

TRM Post Accident Monitoring instrumentation 3.3.4 Rev. 8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME OR D.2 Verify SRV tailpipe Immrediately temperature indication and alarm are available for the AND tailpipe associated with the inoperable acoustic monitor.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter OR D.3 Verify that the following Immediately alternate mnonitoring methods in TS Table 3.3.3.1-1 are OPERABLE:

AND o Function 1 S

Function 2 Function 3 Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />

  • Function 10 thereafter AND 0.4.

Restore the required 30 days channel(s) to OPERABLE status.

OR_

At next outage with containment entry, not to exceed the next refueling outage for in-accessible containment components.

SUSQUEHANNA - UNIT 2 T*

! 3.3-9a SUSQEHANA UNT 2 RM 3.-9aEFFECTIVE DATE 061.3012010

TRM Post Accident Monitoring instrumentation 3.3.4 Rev. 8 TECHNICAL REQUIREMENT SURVEILLANCE

1.

Refer to Table 3.3.4-1 to determine which TR*s apply for each Post Accident Monitoring Function.

2.

W~hen a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or an associated function is available.

1 SURVEILLANCE FREQUENCY TRS 3.3.4.1 Perform CHANNEL CHECK 31 days TRS 3.3.42.

Perform CHANNEL FUNCTIONAL TEST 92 days TRS 3.3.4.3 Perform a CHANNEL CALIBRATION. The Trip 24 months Setpoint shall be less than or equal to 0.25 of the full open noise level.

TRS 3.3.4A4 Perform CHANNEL CALUBRATION 24 months TRS 3.3.4.5 Perform CHANNEL CALIBRATION of the Primary 92 days Containment H2 and 02 Analyzers.

.9P I

TRM ! 3.3-10 SUSQEHANA UNT 2 RM 3.-10EFFECTIVE DATE 1013112007

TRM Post Accident !Monitoring Instrumentation

,Q.Rev.

8 3.3.4 TABLE 3.3.4-1 TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OThER REFERENCED SPECIFIED REQUIRED

FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE
1.

Suppression Chamber Air 1.2 2

C TRS 3.3.4.1 Temperature TRS 3.3.4.4

2.

Main Steam Safety/Relief Valve 1,2 1/valve D

TRS 3.3.4.1 Position Indicator (Acoustic TRS 3.3.4.2 Monitor)

TRS 3.3.4.3

3. Reactor Building Vent Noble Gas Monitor
a. Mid Ranger°

.1,2, (a) 1 B

TRS 3.3.4.1 TRS 3.3.4.4 Sb.

High Range* 1 1,2, (a) 1 B

TRS 3.3.4.1

~TRS 3.3.4.4

4. Standby 'Gas Treatment System Vent Noble Gas Monitor
a. Mid Range(b) 1,2, (a) 1 B

TRS 3.3.4.1 TRS 3.3.4..4

b. High Range(b) 1,2, (a)

I B

TRS 3.3.4.1 TRS 3.3.4.4

5.

Turbine Building Vent Noble Gas Monitor

a. Mid Range(b) 1,2 1

B TRS 3.3.4.1

"]'RS 3.3.4.4

b. High Range'(b) 1,2 1

B TRS 3.3.4.1 TRS 3.3.4.4 (continued)

SUSQUEHANNA - UNIT 2 TRM 1 3.3-11 EFFECTIVE DATE 1010712015

I Rev. 8 TIRM Post Accident Monitoring instrumentation 3.3.4 TABLE 3.3.4-1 (conhinued)

TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECiFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITlONS

'CHANNELS ACTION A.1 SURVE]LI_.ANCE

6. Standby Gas Treatment System Vent Stack Sampling System Flow I
a. Effluent System 1,2,,(a) 1 C

TRS 3.3.,4.1 flow rate monitor~b TRS 3.3.4.4

b. Sampler flow rate 1,2, (a)

IC TRS 3.3.4.1 monitor~b TRS 3.3.4.4

7. Turbine Building Vent Stack Sampling System Flow
a. Effluent System flow rate monitor(b) 1,2 1C TRS 3.3.4.1 TRS 3.3.4.4
b. Sampler flow rate monitor~b 1,2 1C TFRS 3.3.4.1.

T[RS 3.3.4.4

8.

Containment H2 and 02 1,2 2

C T[RS 3.3.4.1 Analyzer(b)

TRS 3.3.4.5 (a) When moving irradiated fuel in the secondary containment.

(b) TRO 3.0.4.c is applicable.

SUSQUEHANNA - UNIT 2 TRM 1 3.3-11a SUSQEHANA UNT 2 RM 3.-haEFFECT IVE DATE 1010712015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRO The primary purpose of the TRM PAM instrumentation is to.display plant variables that provide information required by the control room operators during accident situations. The OPERABIL ITY of the TRM PAM instrumentation ensures that the identified information is available on selected plant parameters to monitor and assess important variables ;following an accident_ This capability is,consistent with the recommendations of Regulatory Guide 1.97 Revision 2, i]nstrumentation for Light Water Cooled Nuclear Power Plants to Assess Plant Conditions During and following an Accidentf NUREG-0578, 'qTMl-2 Lessons i.eamed Task Force Status Report and Short-Term Recommendations= and NEDO-331 60-A Revision 1, *Regulatory Relaxation For The Post Accident SRV Position Indication System= (Reference 6). It should be noted that the Technical Specificatio~ns LCO 3.3.3.1 contains all,Category 1, non-type A instruments and Regulatory Guide 1.97 Type A instrument (References 1 and 2). This TRO requires instruments outside of these criteria.

Table 3.3.4-1 identifies the following required Functions. Suppression Chamber Air Temperature provides a post accident indication of problems with the primary containment pr:essure suppre.ssion system. The Suppression Chamber Air Temperature loops are comprised of the following instruments for the purposes of this TRM. The recorders are the primary method of indicaton used by operator during an accident; therefore, the PAM specification deals specifically with this portion of the instrument.

LOOPA.

LOOP B TE-25703 TE-25725 TT-25703 TT-25725 TR-25795A TR-25795B Main Steam SafetylRelief Valve Positon lndicators (Acoustic Monitors) provide indication when the valves are functioning. Alternate methods for monitoring SRV position include SRV Tailpipe TemPerature and the following Functions from Technical Specification Table 3.3.3.1-1:

Suppression Chamber Water Level (Function 3)]

Suppression,Chamber Water Temperature (Function 10)

Reactor Vessel Water Level (Function 2)

Reactor Steam Dome Pressure (Function 1)]

,(continued)

SUSQUEHANNA - UNIT 2 TRM ] B 3.3-4 SUSQEHANA

-UNI 2 RM IB 33-4EFFECTIVE DATE 06130/2010

TRM Post Accident Monitoring Instrumentation B 3.3A Rev. 5 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES I

TRO (continued)

The required channels for REACTOR BUILDING VENT Noble Gas Monitor, Standby Gas Treatment System Vent Noble Gas Monitor. and Turbine Building Vent Noble Gas Monitor provide information regarding the release of radioactive materials to allow for early indication,of the need ;to initiate action necessary to protect the public and for an estimate of the magnitude of any impending threat.

For the Noble Gas Monitors the,only required channels are the mid range and high range.

The drywell and suppression,chamber hydrogen and oxygen concentrations gas analyzers monitor hydrogen and oxygen concentration to detect combustible gas levels in primary containment The analyzers are capable of determining hydrogen concentration in the range of 0 to 30% by volume and oxygen concentration in the range of 0 to 10% by volume, and each provide control room indication and output to a control room recorder. Each gas analyzer mus~t be capable of sampling either the drywell or the suppression chamber. The recorders are the primary method of indication available for use by the operator during an accident2 therefore the PAM Specification deals specifically with this portion of the instrument channel. The gas analyzer piping is provided with heat tracing to reduce the buildup of condensatidn in the system. 1H202 Aihalyzers can be considered OPERABLE for accident monitoring for up to 100 days with their heat tracing INOPERABLE.

0 ACTIONS The Actions are defined to ensure proper corrective measures are taken in response to the inoperable components.

During construction activities that replace existing SPING equipment with new VERMS equipment, the Vent Noble Gas Monitor for each release path is anticipated to be inoperable for longer than 7 days. Restoration completion time to return the affected channel to OPERABLE status to support,construction activities is extended to 30 days. This condition is compensated for by the enhanced Preplanned Alternate Monitoring Plan per REQUIRED ACTION B3.1.

(continued)

SUSQUEHANNA - UNIT 2 TRM /:B 3.3-5 SUSQEHANA

-UNI 2 RM IB 33-5EFFECTIVE DATE "1010712015

TRM Post Accident Monitoring Instrumentation Rev. 5 B 3.3.4 B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES ACTIONS (continued)

Action D :requirements were determined by balancing the safety significance of the system with the impact of the actions on the operating unit_ The 'loss of the acoustic monitors is not safety significant providing the diverse and redundant alternate methods of determining SRV position are available. System components in the control room are restorable witin 30 days without unit operation impact. Components located in containment require a unit shutdown to gain access to individual components.,The system channels shall be restored to operable condition at eaiiiest opportunity.

Noble gas monitoring may be interrupted for up to 30 minutes to perform particulate filter/iodine cartridge changeout required by TRM Table 3.11.2-1 without entering,the TRO ACT*IONS.

Components,of alternate SRV position systems may be taken inoperable for routine surveillances and periodic maintenance providing the appropriate LCO requirements are met during this action statement. Tailpipe temperature is the direct process monitoring, alternate method and is not covered by Technical Specification LCO's as are the other alternative methods.

TRS The Technical Requirement Surveillances (TRS) are :modified by two Notes.

Note I states that the TRSs for each Post Accident Monitoring instrumentation Function are located in the SR column of Table 3.3.4-1.

Note 2 modifies the Surveillances to indicate that when a channel is placed in a inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or associated Function are available. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken.

(continued)

SUSQUEHANNA - UNIT 2 TRM / B 3.3-6 SUSQEHANA

-UNI 2 RM IB 33-8EFiFECTIVE DATE 10/0712015

TRM Post Accident Monitoring ilnstrumentation Rev. 5 B 3.3.A B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS (continued)

The alternate means of monitoring the parameter or The associated function are:

P~r'nmtf*r Suppression Chamber Air Temperature Main Steam SafetylRellief Valve Position 1Indilcator Containment IH2 and 02 Analyzer One channell of Suppressioen Cihamber Air Temperature Suppression Pool levell Suppression [Pooll Temperature RPV 1level RPV pressure SRV Tailpilpe Temaperature One channel of Containment 1-1 and '02 The TRSs are defined to be peif~ormed at the specified Frequency to ensure that the TRM PAM Function is maintained OPERABLE

((continued)

SUSQUEHANNA - UNIT 2 TRM/B &3*

SUSUEHNNA-UIT TR I 3~-7EFFECTIVE DATE 101.0,712015

F i

~TRM :Post Accident Monitoring Instrumentation SRev.

5 B 3.3.4 O :-

B 3.3.4 TRM Post Accident Monitoring (PAM) Instrumentation BASES TRS TRS 3.3.4.1 (continued)

Performance of the CHANNEL CHECK once every 31 days ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel against a similar parameter on other channels. it is based.on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations be tween instrument channels could be an indication of excessive instrument drift in one of the :channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to opefate properly between each CHANNEL CALIBRATION.

Agreement criteria, which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability..

If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit and does not necessarily indicate the channel is inoperable.

O ':-REFERENCES

1.

Regulatory Guide 1.97 Revision 2, "instrumentation for Light Water Cooled Nuclear 'Power Plants to Assess Plant and Environs Conditions During and Following an Accident.)'

2.

NUREG-0578, "iTMi-2 Lessons Learned Task Force Status Report and Short-Term Recommendations.=

3.

Technical Specification Amendment No. 100 to License No. NPF-22. for failed Unit 2 "S" acoustic monitor.

4.

Technical Specification Amendment No. 169 to License No. NPF-14 for failed Unit I US" acoustic monitor.

5.

Proposed amendment No. 183 to License No. NPF-22 failed Unit 2 "Jo acoustic monitor.

6.

NEDO-33160-A, Revision 1, ='Regulatory Relaxation For The Post Accident SRV Position Indication System,= dated October 2006.1

7.

NRC letter, "Final Safety Evaluation For Boiling Water Reactor Owners' Group (BWROG) Topical Report (TR) NEDO-33160, Regulatory Relaxation For The Post Accident SRV [Safety Relief Valve] Position

~Indication System.(TAG No. MC5446)," dated September 26, 2005.

SUSQUEHANNA - UNIT 2 TRM/B3.3*

SUSQEHANA-UIT TRMlB 33-8EFFECTIVE DATE 0613012010