June 7, 1989 Docket Nos.: 50-269, 50-270 and 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242
Dear Mr. Tucker:
SUBJECT:
SAFETY EVALUATION FOR GENERIC LETTER 83-28, ITEM 4.5.3, REACTOR TRIP RELIABILITY - ON-LINE FUNCTIONAL TESTING OF THE REACTOR TRIP SYSTEM (TACS 54005/54006/54007)
Generic Letter 83-28, Item 4.5.3, required confirmation from all licensees and applicants that on-line functional testing of the reactor trip system, including independent.testing of the diverse trip feature, was being performed.
By letter dated August 9, 1985, you submitted your response to Generic Letter 83-28, Item 4.5.3.. Therein you indicated your endorsement of the B&W Owners' Groups Report 1CAN048504, as being applicable to Oconee Nuclear Station, Units 1, 2 and 3. The NRC staff, with the assistance of our contractor, Idaho National Engineering Laboratory, has reviewed your response and the B&W Owners'Group's report. We conclude that the existing intervals for on-line functional testing at Oconee are consistent with achieving high reactor trip system availability.
The enclosed safety evaluation and contractor's report (EGG-NTA 8341) provide the details and basis for our conclusion. Therefore, we consider Generic Letter 83-28, Item 4.5.3 to be-completed.
This completes all staff activities related to TAC Nos. 54005/54006/54007.
Sincerely, Leonard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -
I/Il Office of Nuclear Reactor Regulation
Enclosures:
As stated cc w/enclosures:
See next page DISTRIBUTION Docket File L. Wiens 0 1 NRC & Local PDRs OGC (for info. only)
Coo 1 PDII-3 Reading E. Jordan, 3302 MNBB S. Varga, 14/E/4 B. Grimes, 9/A/2 G. Lainas, 14/H/3 ACRS (10)
D. Matthews Oconee Gray File M. Rood B. Mozafari, 14/B/
LA' 1-3 PRPII-3 D:P DII-3 oo LWiens:bd
/,Matthews
~/O89 573o/89 U
3/31/89
Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:
Mr. A. V. Carr, Esq.
Mr. Paul Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.
Bishop, Cook, Purcell & Reynolds Mr. Alan R. Herdt, Chief 1400 L Street, N.W.
Project Branch #3 Washington, D.C. 20005 U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Mr. Robert B. Borsum Atlanta, Georgia 30323 Babcock & Wilcox Nuclear Power Division Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike N. C. Department of Justice Rockville, Maryland 20852 P.O. Box 629 Raleigh, North Carolina 27602 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 34623-1693 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621