May 30, 1986

  • b "NE 40 Dockets Nos. 50-269, 50-270 and 50-287 Mr.

Hal B. Tucker Vice President - Nuclear Production Duke Power Company P. 0. Box 33189 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

SUBJECT:

STEAM GENERATOR TUBE SLEEVING PROGRAM REQUEST FOR ADDITIONAL INFORMATION Re: Oconee Nuclear Station, Units 1, 2 and 3 We have been reviewing your January 16, 1986 request to use sleeving as a repair method for the steam generator tubes. To complete our review, we need the additional information identified in the enclosure.

We request that you respond to this request for additional information within thirty days of the date of this letter.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

John F. Stolz, Director PWR Project Directorate #6 Division of PWR Licensing-B

Enclosure:

Request for Additional Information cc w/enclosure:

See next page Distribution:

ket Filal.

NRC & L PDRs Branch 6 Files RIngram CMcCracken, JStolz HPastis JPartlow BGrimes OELD ACRS 10 FMiraglia PWR# 6 PWR#6 P

HPastis

-G+1ek e e JSt Y

/yy8 6 1 /O186

//

8606250419 860530 PDR ADOCK 05000269 P

PDR

Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:

Mr. William L. Porter Mr. Paul F. Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.

Bishop, Liberman, Cook, Purcell & Reynolds 1200 Seventeenth Street, N.W.

Washington, D.C. 20036 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621

REQUEST FOR ADDITIONAL INFORMATION STEAM GENERATOR TUBE SLEEVING PROGRAM OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 DOCKET NOS. 50-269, 50-270 AND 50-287

1. Provide the basis for the area dose rate estimates indicated in Section 4.4 of Exhibit B to your January 16, 1986 letter requesting an amendment to the Oconee Facility Operating License and revision to the Technical Specifica tions concerning the steam generator tube sleeving program.
2. Only "no contingency" steam generator tube sleeving operational dose esti mates are provided. Provide a table with the operational dose estimates including conservative estimates of contingencies expected in the sleeving operation.

Include the same detail provided on Page 4-6 of Exhibit B.

3. Provide a discussion of your training program to be provided to the workers involved in the steam generator tube sleeving operations utilizing the provisions of Regulatory Guide 8.27, 8.19 and 8.13 as guidance, or outline an equivalent training program.