ML15260A279

From kanterella
Jump to navigation Jump to search

Advises That Response to NRC Bulletin 89-001,suppl 2, Failure of Westinghouse SG Tube Mechanical Plugs, Acceptable
ML15260A279
Person / Time
Site: Oconee  
Issue date: 03/20/1992
From: Wiens L
Office of Nuclear Reactor Regulation
To: Hampton J
DUKE POWER CO.
References
IEB-89-001, IEB-89-1, TAC-M81639, TAC-M81640, TAC-M81641, NUDOCS 9203260162
Download: ML15260A279 (4)


Text

March 20, 1992 Docket Nos. 50-269, 50-270 and 50-287 Mr. J. W. Hampton Vice President, Oconee Site Duke Power Company P. 0. Box 1439 Seneca, South Carolina 29679

Dear Mr. Hampton:

SUBJECT:

RESPONSE TO NRC BULLETIN 89-01, SUPPLEMENT 2, "FAILURE OF WESTINGHOUSE STEAM GENERATOR TUBE MECHANICAL PLUGS" -

OCONEE UNITS 1, 2, AND 3 (TACS M81639/M81640/M81641)

On June 28, 1991, NRC Bulletin 89-01, Supplement 2, was issued to all holders of operating licenses.or construction permits for pressurized water reactors (PWRs).

The supplement requested that actions similar to those requested in NRC Bulletin 89-01, "Fail ure of Westinghouse Steam Generator Tube Mechanical Plugs," be extended to include all Westinghouse mechanical plugs fabricated from thermally treated Inconel 600.

These actions were necessary to ensure that these plugs would continue to provide adequate assurance for reactor coolant system (RCS) pressure boundary integrity under normal operating, transient, and postulated accident conditions.

By letter dated August 9, 1991, you responded to Bulletin 89-01, Supplement 2, by providing the information addressed in the Actions Requested portion of that document. We have reviewed your response for Oconee, Units 1, 2, and 3 and find the informa tion and planned actions to be acceptable. Therefore, we are closing TAC Nos. M81639, M81640, and M81641.

Sincerely, L. A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation cc:

See next page Distribution:

See next page LA:PDII-I-3

'P I//

LBerry LWiens/rst DMatthews 5/-D/ 9 2

-) /;p / 92

//9 2

OFFICIAL RECORD COPY Document Name:

A:BULL8901 9203260162 920320 PDR AD0CC 05000269ZF

t~tREGO&,

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 205 o4 March 20, 1992 Docket Nos. 50-269, 50-270 and 50-287 Mr. J. W. Hampton Vice President, Oconee Site Duke Power Company P. 0. Box 1439 Seneca, South Carolina 29679

Dear Mr. Hampton:

SUBJECT:

RESPONSE TO NRC BULLETIN 89-01, SUPPLEMENT 2, "FAILURE OF WESTINGHOUSE STEAM GENERATOR TUBE MECHANICAL PLUGS" -

OCONEE UNITS 1, 2, AND 3 (TACS M81639/M81640/M81641)

On June 28, 1991, NRC Bulletin 89-01, Supplement 2, was issued to all holders of operating licenses or construction permits for pressurized water reactors (PWRs).

The supplement requested that actions similar to those requested in NRC Bulletin 89-01, "Fail ure of Westinghouse Steam Generator Tube Mechanical Plugs," be extended to include all Westinghouse mechanical plugs fabricated from thermally treated Inconel 600.

These actions were necessary to ensure that these plugs would continue to provide adequate assurance for reactor coolant system (RCS) pressure boundary integrity under normal operating, transient, and postulated accident conditions.

By letter dated August 9, 1991, you responded to Bulletin 89-01, Supplement 2, by providing the information addressed in the Actions Requested portion of that document. We have reviewed your response for Oconee, Units 1, 2, and 3 and find the informa tion and planned actions to be acceptable. Therefore, we are closing TAC Nos. M81639, M81640, and M81641.

Sincerely, L. A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation cc:

See next page

Mr. J. W. Hampton Duke Power Company Oconee Nuclear Station cc:

Mr. A. V. Carr, Esquire Mr. M. E. Patrick Duke Power Company Compiance 422 South Church Street Duke Power Company Charlotte, North Carolina 28242-0001 Oconee Nuclear Site P. 0. Box 1439 J. Michael McGarry, III, Esquire Seneca, South Carolina 29679 Winston and Strawn 1400 L Street, NW.

Mr. Alan R. Herdt, Chief Washington, DC 20005 Project Branch #3 U. S. Nuclear Regulatory Commission Mr. Robert B. Borsum 101 Marietta Street, NW. Suite 2900 Babcock & Wilcox Atlanta, Georgia 30323 Nuclear Power Division Suite 525 Ms. Karen E. Long 1700 Rockville Pike Assistant Attorney General Rockville, Maryland 20852 North Carolina Department of Justice Manager, LIS P. 0. Box 629 NUS Corporation Raleigh, North Carolina 27602 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Mr. R. L. Gill, Jr.

Licensing Senior Resident Inspector Duke Power Company U. S. Nuclear Regulatory Commission P. 0. Box 1007 Route 2, Box 610 Charlotte, North.Carolina 28201-1007 Seneca, South Carolina 29678 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, NW. Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 County Supervisor of Oconee County Walhalla, South Carolina 29621

March.20, 1992 Distribution (pocket File NRC & Local PDRs PDII-3 R/F Oconee R/F S. Varga G. Lainas D. Matthews L. Berry L. Wiens OGC ACRS (10)

L. Reyes, RII L. Engels E. Murphy