ML15238A584
| ML15238A584 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 05/11/1982 |
| From: | Novak T Office of Nuclear Reactor Regulation |
| To: | Dail L DUKE POWER CO. |
| References | |
| NUDOCS 8205200331 | |
| Download: ML15238A584 (3) | |
Text
Sg p
AY 1 1 199 Docket File Dockets Nos. 50-269/270/287 ocal PDR i9Rs 319z I:1 RB #4 Rdg Eisenhut Mr. L.
C. Dail O
OELD Vice President -
Design Engineer OI&E (1)
Duke Power Company 4
PCWagner P. 0. Box 33189 RIngram 422 South Church Street NSIC J
4.
(
Charlotte, North Carolina 28242 ACRS (10)
JHeltRmes
Dear Mr. Dail:
(
I have discussed your March 29, 1982 letter to me with members of the Office of Nuclear Reactor Regulation (NRR) staff and have determined that a formal response to the acceptability, on a generic basis, of your pro posal is within the purview of the Office of Nuclear Regulatory Research (RES) rather than NRR. I have, therefore, forwarded your letter to the Division of Engineering Technology, RES, for response.
The Division of Licensing, NRR, plans no further action on your March 29, 1982 request, but would review a plant specific proposal related to any of the nuclear plants licensed, or being constructed, by Duke Power Company.
Such a request should be docketed through your normal licensing process and contain sufficient bases for the staff to make an evaluation of its acceptability. In addition, there appears to be a misinterpretation of the agreements reached during our staff's February 9, 1982 meeting and subsequent March 1, 1982 telephone conferences for which the following clarification is provided:
Item 1 The ALARA concept is used to assess the economic feasibility of augmented waste treatment equipment or systems based on expected reduction in off-site collective dose during normal operation and estimated cost of the equipment
($1000 per man-rem).
It has not been used in the evaluation of structural design nor in the consideration of accident consequences.
Item 2 As specified in our Standard Review Plan, Section 15.7.3, credit for liquid retention by unlined building foundations will not be given regardless of the building seismic category because of the potential for cracks. However, we limit our assumption to the loss of the contents of a single tank rather than the total liquid contents of the building.
8205200331 820511 PDR ADOCK 05000269 P
PDR OFFICE)
SURNAME)
DATEb.....................................................................................................................................
NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960
Mr. L. C. Dail
- 2 Item 5 The staff addressed the need for a graded QA program which takes into consideration the relative importance to safety of each aspect of facility design. This seemed to be consistent with Duke's application of an ALARA concept with respect to QA. However, at no time did we agree that this "excludes all portions of the structure, including the seismically designed
'bathtub',....".
If you have any questions on this matter, please contact the NRC's Project Manager for Oconee - P. C. Wagner at (301) 492-8213.
Sincerely, Thomas M. Novak, Assistant Director for Operating Reactors Division of Licensing cc: See next page OFI DL:0RB#4 1 RB#4 SURNAMEb.........
- ......I.... K..............
PCWagner:mE J
TMNovak sURNAME NRc FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960
Duke Power Company cc w/enclosure(s):
Mr. William L. Porter Duke Power Company P. 0. Box 33189 422 South Church Street Office of Intergovernmental Relations Charlotte, North Carolina 28242 116 West Jones Street Raleigh,.North Carolina 27603 Oconee County Library 501 West Southbroad Street Walhalla, South Carolina 29691 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621 Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission, Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Mr. William 0. Parker, Jr.
Vice President -
Steam Production Duke Power Company P. 0. Box 33189 Regional Radiation Representative 422 South Church Street EPA Region IV Charlotte, North Carolina 28242
.345 Courtland Street, N.E.
Atlanta, Georgia 30308 William T. Orders Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Mr. Robert B. Borsum
.Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Manager, LIS NUS Corporation 2536 Countryside BoulevardP Clearwater, Florida 33515 J. Michael McGarry, III, Esq.
DeBevoise & Liberman 1200 17th Street, N.W.
- h.