10 CFR 50.55a Saps Palo Verde Nuclear Generating Station 102-07077-TNW/DCE P.O. Box 52034 July 15, 2015 Phoenix, AZ 85072 Mail Station 7636 Tel 623 393 5764 A-TN: Document Control Desk 11555 Rockville Pike Rockville, MD 20852
References:
- 1.
Arizona Public Service Company (APS) letter number 102-07037, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, Transmittal of Proprietary Documents for Relief Request 53, dated April 17, 2015, Agencywide Documents Access and Management System [ADAMS] Accession Number ML15111A289
- 2.
APS letter number 102-07034, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, American Society of Mechanical Engineers (ASME)
Code,Section XI, Request for Approval of an Alternative to Flaw Removal -
Relief Request 53, dated April 17, 2015, ADAMS Accession Number ML15111A429
- 3. APS letter number 102-07085, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, Transmittal of Updated Proprietary Documents for Relief Request 53, dated July 15, 2015
Dear Sir:
Subject:
Palo Verde Nuclear Generating Station (PVNGS) Unit 3 Docket No. 50-530 Transmittal of Non-Proprietary Documents for Relief Request 53 On April 17, 2015, pursuant to 10 CFR 50.55a(z)(1), Arizona Public Service Company (APS) submitted References 1 and 2 for Nuclear Regulatory Commission (NRC) approval of Relief Request 53. The letters provided proprietary documents and non-proprietary documents, respectively. Reference 3 provides five updated proprietary versions of the proprietary documents provided in Reference 1.
This letter transmits non-proprietary versions of the documents contained in the Enclosures to References 1 and 3.
There are no commitments made to the NRC by this letter.
A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Pc Callaway - Di-ablo Canyon - Palo Verde - Wolf Creek
102-07077-TNW/DCE ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Transmittal of Non-Proprietary Documents for Relief Request 53 Page 2 If you have any questions or require additional information, please contact Michael D. Dilorenzo, Nuclear Regulatory Affairs Department Leader, at (623) 393-3495.
Sincerely, Thomas N. Weber Nuclear Regulatory Affairs Department Leader TNW/DCE/akf
Enclosure:
Non-Proprietary Documents for Relief Request 53 cc (w/ enclosure):
M. L. Dapas M. M. Watford C. A. Peabody NRC Region IV Regional Administrator NRC NRR Project Manager NRC Senior Resident Inspector for PVNGS
ENCLOSURE Non-Proprietary Documents for Relief Request 53
Enclosure Non-proprietary Documents for Relief Request 53 On April 17, 2015, pursuant to 10 CFR 50.55a(z)(1), Arizona Public Service Company (APS) submitted References 1 and 2 for Nuclear Regulatory Commission (NRC) approval of Relief Request 53. The letters provided proprietary documents and non-proprietary documents, respectively. Reference 3 provides five updated proprietary versions of the proprietary documents provided in Reference 1.
The attachments to this Enclosure provide non-proprietary documents provided in References 1 and 3. The updated proprietary documents in Reference 3 identify the proprietary content portions of the documents that have been removed in Attachments 2 through 6 of this Enclosure. This identification was not provided in the original transmittal of the documents in Reference 1..
The attachment numbers used in this Enclosure correlate to those provided in the enclosures to References 1 and 3. Attachment 1 of this enclosure is a placeholder to preserve the attachment number correlation among the attachments. The original document listed in Attachment 1 was provided in Reference 2 as a non-proprietary version. - Westinghouse Document DAR-MRCDA-1 5-6-NP, Rev. 1, Palo Verde Unit 3 RCS Cold Leg Alloy 600 Small Bore Nozzle Repair - Westinghouse Calculation CN-MRCDA-1 5-13-NP, Rev. 0, Qualification of Palo Verde Unit 3 Reactor Coolant Pump Replacement Instrumentation Nozzle - Westinghouse Calculation CN-PAFM-1 5-20-NP, Rev. 2, Palo Verde Unit 3 RCS Cold Leg Alloy 600 Small Bore Nozzle Repair Transient Stress and Fracture Mechanics Evaluation for One Cycle Operation - Westinghouse Calculation TR-FSE-1 5-2-NP, Rev. 1, Palo Verde Nuclear Generating Station Unit 3 Evaluation of Potential Loose Part - Reactor Coolant Pump Instrument Nozzle Weld Fragment - Westinghouse Letter, LTR-ME-1 5-30-NP, Rev. 2, ASME Code Section X1 Reconciliation for Arizona Public Service (APS), Palo Verde Nuclear Generating Station (PVNGS) Unit 3 Replacement Instrument Nozzle - Westinghouse Calculation CN-NPE-06-XXXX-03-NP, Rev. 1, Plant X - Structural Evaluations of the RCP Pressure Tap Nozzles - Drawings Referenced in Responses to NRC Questions C-8000-101-2017-NP, Rev 2, Wall Static Pressure Suction STD-009-0009-NP, Rev. 2, Coolant Pumps Weld Joint Identification and Fabrication Requirements 1
Enclosure Non-proprietary Documents for Relief Request 53
" C-14473-220-002-NP, Rev. 0, Replacement Pressure Tap Nozzle
" E-14473-220-001 -NP, Rev. 0, Pump Casing -A Pressure Tap Nozzle Modification Assembly
" SE-1 4473-220-003-NP, Rev. 0, Pressure Tap Nozzle Replacement Palo Verde Unit 3
References:
- 1. Arizona Public Service Company (APS) letter number 102-07037, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, Transmittal of Proprietary Documents for Relief Request 53, dated April 17, 2015, Agencywide Documents Access and Management System
[ADAMS] Accession Number ML15111A289
- 2. APS letter number 102-07034, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, American Society of Mechanical Engineers (ASME) Code, Section Xl, Request for Approval of an Alternative to Flaw Removal-- Relief Request 53, dated April 17, 2015, ADAMS Accession Number ML15111A429
- 3. APS letter number 102-07085, Palo Verde Nuclear Generating Station Unit 3, Docket No. STN 50-530, Transmittal of Updated Documents for Relief Request 53, dated July 15, 2015 2
Enclosure Non-proprietary Documents for Relief Request 53 Westinghouse Document DAR-MRCDA-15-6-NP, Rev. 1, Palo Verde Unit 3 RCS Cold Leg Alloy 600 Small Bore Nozzle Repair Note:
This attachment was inserted for the sake of preserving the correlation between the attachment numbers of this Enclosure and those of the referenced letters. No document is attached.