1 NRR-PMDAPEm Resource From:

Thomas.N.Weber@aps.com Sent:

Wednesday, April 15, 2015 12:14 PM To:

Watford, Margaret Cc:

Delbert.Elkinton@aps.com; George.Andrews@aps.com; Carl.Stephenson@aps.com; Ken.House@aps.com

Subject:

File for NRC Phone Call Attachments:

Agenda for Phone Call 4-15-15.pdf

Maggie, Attached please find the agenda and two figures that we plan to use today on the phone call. Can you distribute to the participants on the call.
Thanks, TN Weber Department Leader Regulatory Affairs PVNGS

Hearing Identifier:

NRR_PMDA Email Number:

2010 Mail Envelope Properties (EB0C94E90ED2EF409E17260ECE38B14E0692FCFB)

Subject:

File for NRC Phone Call Sent Date:

4/15/2015 12:13:55 PM Received Date:

4/15/2015 12:14:11 PM From:

Thomas.N.Weber@aps.com Created By:

Thomas.N.Weber@aps.com Recipients:

"Delbert.Elkinton@aps.com" <Delbert.Elkinton@aps.com>

Tracking Status: None "George.Andrews@aps.com" <George.Andrews@aps.com>

Tracking Status: None "Carl.Stephenson@aps.com" <Carl.Stephenson@aps.com>

Tracking Status: None "Ken.House@aps.com" <Ken.House@aps.com>

Tracking Status: None "Watford, Margaret" <Margaret.Watford@nrc.gov>

Tracking Status: None Post Office:

ntm211.apsc.com Files Size Date & Time MESSAGE 251 4/15/2015 12:14:11 PM Agenda for Phone Call 4-15-15.pdf 2120674 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Agenda for NRC Phone Call April 15, 2015 RCP 2A Nozzle Relief Request

1. Introductions
2. Original Design of RCP 2A Nozzle
3. Recap of Discovery of Condition
a. Results of visual inspection of RCP 2A nozzle
b. Visual inspection of remaining nozzles (EOC)
c. Results of dye penetrant supplemental inspection
d. Results of straight beam UT supplemental inspection of original nozzle
4. Half-Nozzle Design of RCP 2A Nozzle
5. Actions Completed
6. Relief Request
a. Summary Description
b. Supporting Analysis
c. Timeframe
7. Summary/Overview of RAI received Tuesday (4-14-15)
8. Questions/Comments

RCP 2A Original Nozzle Arrangement

Enclosure

  • NPS -nominal pipe size Item Description Dimensions (inches)

Material Note A

Safe-end Clad and Butter 309 Stainless, 82 or 182 inconel B

Remnant Nozzle Orifice 1 NPS* x 0.190 diameter Outlet end (removed) was former Class 1 code break C

Remnant J-groove Weld 82 or 182 inconel Former RCS pressure boundary D

Safe-end Pipe Wall 3 thick Carbon Steel E

Remnant Nozzle-half 1 NPS x 1.5 Alloy 600 F

Replacement Nozzle 1 NPS Alloy 690 G

Replacement Nozzle Orifice 0.190 diameter Outlet end is new Class 1 code break H

Replacement J-groove Weld 0.5 ERNiCrFe-7A (filler)

New RCS pressure boundary A

B C

D E

F G

H Figure 1 RCP 2A Suction Safe-end Repaired Instrument Nozzle