Attachment 2 Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation - 2014 (Non-Proprietary)

'Structural Integrity Associates, inc.

File No.: 1400734.301 Project No.: 1400734 CALCULATION PACKAGE Quality Program: [] Nuclear LI Commercial PROJECT NAME:

NIMPi Steam Dryer Support Bracket Flaw Evaluation CONTRACT NO.:

532400 CALCULATION TITLE:

Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation - 2014 Non-Proprietary Version Document Affected Project Manager Reiin PgsRevision Description Approval Preparer(s) & Checker(s)

Reison PaesSignature

& Date Signatures & Date 01

- 27 Initial Issue A-1 -A-27 Responsible Engineer:

D. Sommerville M. Walter 1/30/2015 1/28/2015 Responsible Verifier:

M. Qin 1/30/2015 Page 1 of 27 F0306-01R2

VStructural Integrity Associates, Inc.Y Table of Contents

1.0 INTRODUCTION

............................................................................. 5 2.0 OBJECTIVE.................................................................................

5..

3.0 METHODOLOGY........................................................................... 5 4.0 ASSUMPTIONS.............................................................................. 6 5.0 DESIGN INPUTS............................................................................ 6 6.0 CALCULATIONS............................................................................ 7 6.1 Flaw Characterization and Growth................................................. 7 6.2 LEFM Analysis for Flaw Stability................................................. 8 6.3 Limit Load Evaluation............................................................... 8 6.4 Comparison of Friction Coefficients............................................... 9 6.5 Computer Files.....................................

2...........................

r...... 9 7.0 CONSERVATISMS.......................................................................... 9

8.0 CONCLUSION

S............................................................................ 10

9.0 REFERENCES

.............................................................................. 11 Appendix A STEAM DRYER SUPPORT BRACKET LEFM EVALUATION..................... A-1 File No.: 1400734.30 1 Revision: 0 Page 2 of 27 F0306-01R2

VStructural Integrity Associates, Inc?

List of Tables Table 1: Summary of Steam Dryer Support Bracket Loads.............................................. 13 Table 2: LEFM Results for Crack Cases Identified in Figure 4......................................... 18 Table 3: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-5 87A, 1-5 87D, Service Level A.......................... 19 Table 4: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket l-587A, 1-587D, Service Level B........................... 20 Table 5: ASMIE B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket l-587B, Service Level A..................................... 21 Table 6: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587B, Service Level B..................................... 22 Table 7: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell,'

Steam Dryer Support Bracket 1-587C, Service Level A..................................... 23 Table 8: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587C, Service Level B..................................... 24 Table 9: Summary of Project Computer Files............................................................. 27 File No.: 1400734.301 Revision: 0 Page 3 of 27 F0306-01R2

Structural Integrity Associates, Inc.*

List of Figures Figure 1. RFO22 Inspection Photographs Showing Contact Locations on Top Surface of Support Brackets and Location of Load Application......................................... 12 Figure 2a. Overlay of RFO22 Inspection Data with NDE Uncertainty and 2 Cycles of SCC Growth............................................................................................ 14 Figure 2b. Overlay of RFO22 Inspection Data with NDE Uncertainty and 2 Cycles of SCC Growth............................................................................................ 15 Figure 3: End of Interval Flaw Configurations Considered for Limit Load Evaluation............... 16 Figure 4: Crack Cases Considered for LEFM Evaluation................................................. 17 Figure 5: Limit Load Results for Steam Dryer Support Bracket Crack Case 1 -

Service Level A - Bounds 1-587A, 1-587D - 2 Cycle SCC Growth....................... 19 Figure 6: Limit Load Results for Steam Dryer Support Bracket Crack Case 1 -

Service Level B - Bounds 1-587A, 1-587D - 2 Cycles SCC Growth...................... 20 Figure 7: Limit Load Results for Steam Dryer Support Bracket Crack Case 2 -

Service Level A - Bounds 1-587B - 2 Cycles SCC Growth................................ 21 Figure 8: Limit Load Results for Steam Dryer Support Bracket Crack Case 2 -

Service Level B - Bounds 1-587B - 2 Cycles SCC Growth................................. 22 Figure 9: Limit Load Results for Steam Dryer Support Bracket Crack Case 3 -

Service Level A - Bounds 1-587C - 2 Cycles SCC Growth................................ 23 Figure 10: Limit Load Results for Steam Dryer Support Bracket Crack Case 3 -

Service Level B - Bounds 1-587C - 2 Cycles SCC Growth................................. 24 Figure 11: Orientation of Paths to Extract Linearized Stresses in RPV Shell.......................... 25 Figure 12: Comparison of Strain for Crack Case 2, Service Level B................................... 26 File No.: 140)0734.301 Page 4 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, Inc.*

1.0 INTRODUCTION

Reportable indications have been observed in the steam dryer brackets at Nine Mile Point Unit 1 (NMP 1). Previous SI calculations [1 and 2] have shown acceptance of the indications for one fuel cycle (two years) using several conservative assumptions.

2.0 OBJECTIVE The objective of the current calculation is to remove some of the conservatism in the old calculations and determine whether the flawed NMP1 steam dryer support brackets can be left in-service, without repair, for two additional operating cycles.

3.0 METHODOLOGY The overall methodology for the current calculation is consistent with the methodology in References [1 and 2]. The following changes are made in the current calculation:

1. The coefficient of static friction is changed from 1.0 to 0.65 for all cases. This is considered to be an upper bound friction coefficient based on Reference [3]. A more mid-range value of 0.5 is also used in Section 6.4. This value is still a fairly conservative value since vibration can lower the coefficient of friction.
2. Different structural factors (SFs) for membrane and bending stress and service level A and service level B are used consistent with ASME Code Section XI, Appendix C [4] instead of a single, bounding structural factor. For the linear elastic fracture mechanics (LEFM) analysis, the SFs are applied to the stress terms and a KI, allowable of 150 ksiP/in is used.
3. The load application location is changed for each bracket to account for actual wear marks found on each bracket using photographs from Reference [5] instead of using a bounding location.

Figure 1 shows the inspection photographs for each bracket with the load application location overlaid on the picture.

4. Inspection uncertainty is removed, when applicable, based on EPRI Letter 2012-024 [6] and EPRI Letter 2012-051 [7]. The following uncertainties are determined as:

a) Ultrasonic Testing (UT) Depth Direction Uncertainty Per Reference [6], {f. The UT depth uncertainty identified in Reference [8] is 0.2 10" or 0.394"; therefore, UT depth uncertainty cannot be removed. b) UT Length Direction Uncertainty Per Reference [6], (( }}. The UT length uncertainty identified in Reference [8] is 0.210" or 0.394" (uncertainty multiplied by two to account for two sides); therefore, UT length uncertainty can be removed. c) Visual Testing (VT) Length Uncertainty Per Reference [6], (( 1}. The VT length uncertainty applied to measurements in Reference [9], based on BWRVIP-03 [10, Section 3.1], (( ,}}; therefore, VT length uncertainty can be removed.

5. A stress corrosion cracking (SCC) growth rate of ((.

}} in the depth direction is used for stainless steel in normal water chemistry (NWC), which is consistent with BWRVIP-14-A File No.: 1400734.301 Page 5 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, Inc? [11]. The UT data sheets report that the location of the flaw tips in all four brackets are well into the stainless steel side of the Inconel weld; the minimum distance between the weld fusion line and the crack tips varies between 0.58 inches and 0.88 inches [2, Section 6.1]. Considering the fabrication details for the lug and the location of the indications, crack growth is expected to remain in the stainless steel material.

6. Plant duty is considered to occur 355 days/year instead of 365.25 days/year. This accounts for outages and other times when the plant is shut down.
7. The reactor internal pressure difference (RlIPD) up-force is included in the limit load analysis.

This was conservatively neglected in the previous calculations since it counteracts the deadweight (DW) forces. A detailed description of all other aspects of the analysis methodology is provided in References [1, Section 4.0 and 2, Section 3.0]. 4.0 ASSUMPTIONS The same assumptions as used in the Reference [1, Section 5.0 and 2, Section 4.0] flaw evaluations are used for the present flaw evaluation with the following exception:

1. Plant duty is considered to occur 355 days/year instead of 365.25 days/year. This accounts for outages and other times when the plant is shut down.

5.0 DESIGN INPUTS The same design inputs as used in the Reference [1, Section 3.0 and 2, Section 5.0] flaw evaluation are used in the present flaw evaluation. Inspection results from the 2013 inspections are used [8 and 9] in this analysis. For the limit load analysis, forces are applied to the top of the bracket at a location consistent with actual wear marks found on each bracket using photographs from Reference [5] instead of using a bounding location as was done in Reference [2]. Figure 1 shows the inspection photographs for each bracket with the load application location overlaid on the picture. The reactor internal pressure difference (RIPD) up-force is included in the limit load analysis using the value calculated in Reference [1, Section 4.1]. This was conservatively neglected in the previous calculations since it counteracts the deadweight forces. For the LEFM analysis, the loads at the top of the bracket are applied conservatively at the outside corner, as was done in Reference [2]. RIPD loads are conservatively neglected in the LEFM analysis since they counteract the deadweight vertical loads. Lateral forces are applied to the side of the bracket as a uniform pressure acting on the side of the bracket, identical to Reference [2]. Flow induced vibration (FlV) loads are assumed negligible based upon inspection results from bracket surfaces [1, Section 5.0]. A summary of the applied loads, including load combinations and safety factors used, is given in Table 1. The boundary conditions applied to the finite element model (FEM) are identical to Reference [1, Section 7.4 and 2, Section 6.3]. The loads and boundary conditions are applied to the FEM identical to Reference [1, Figure 14 and 2, Figure 10] with the exception of the forces of the top of the bracket which are applied at locations shown in Figure 1. File No.: 1400734.301 Page 6 of 27 Revision: 0 F0306-01R2

~jStruotural Integrity Associates, Inc? 6.0 CALCULATIONS The calculations performed for the following aspects of the evaluation are documented in this section:

1. Flaw characterization and growth
2. LEFM evaluation for flaw stability
3. Limit Load analysis Since the remaining ligament for the bounding bracket (Bracket B) would be very small if an additional cycle (6 years total) of crack growth is considered, adding contact elements will not provide any benefit to this analysis and are therefore not considered.

6.1 Flaw Characterization and Growth The UT data sheets report that the location of the flaw tips in all four brackets are well into the stainless steel side of the Inconel weld; the minimum distance between the weld fusion line and the crack tips varies between 0.58 inches and 0.88 inches [2, Section 6.1]. Considering the fabrication details for the lug and the location of the indications, crack growth is expected to remain in the stainless steel material. The initial flaw sizes are increased to account for NDE uncertainty (when applicable) as well as crack growth from SCC. In References [1, Section 7.2 and 2, Section 6.1], it was shown that FCG from system cycling is negligible and is therefore not considered in the present calculation. The flaws in brackets 1-587A, 1-587B, and 1-587C are grown for two fuel cycles (4 years) using stainless steel crack growth rates (CGRs). Since the flaw in bracket 1-587A bounds the flaw in bracket 1-587D, bracket 1-587D is not evaluated. Similar to what was done in References [1, Section 7.2 and 2, Section 6.1], the depth of the visual indications that were not detected by UT are assumed to be the minimum detection limit of the UT method [8] equal to 0.2 inches; therefore, all visual indications that were not detected by UT are assumed to have a depth of 0.2 inches prior to crack growth. SCC growth is considered using the bounding, K-independent, NWC crack growth for the stainless steel base material reported in BWRVIP-14-A [11, Section 6.1.1]. The SCC CGRs are:

  • Length direction:

5.0 x 10.-5 in/hr

  • Depth direction:

((} The total SCC growth added to each flaw tip, for the evaluation interval, is: Length: 2 Cycle: Asc=355.4.24. 5.0x10-s = 1.704 in!/tip Det: 2 Cycle: Aascc = 355 *4 *24 * { } = 0.750 in!/ tip Figure 2 shows the inspection data from RFO22 with uncertainty and SCC growth added. This figure uses inspection data from References [8 and 9] and is similar to Reference [2, Figure 6] with the modifications of inspection uncertainty and two cycles of SCC growth instead of one cycle. Figure 3 File No.: 1400734.301 Page 7 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, /nc2 shows the crack cases used for the limit load analysis. These cases provide bounding dimensions based on Figure 2 end of interval dimensions. 6.2 LEFM Analysis for Flaw Stability Appendix A contains the MathCAD file listing used to perform the LEFM evaluation. The following two cases are chosen to bound all cracks in all four support brackets:

1. A 3.444 inch deep edge crack located across the short axis of the lug with a 0.95 inch deep edge crack located across the long axis of the lug. (A minimum crack depth of 0.95 inch is used since the uncertainty in the depth direction is 0.20 inch with 0.75 inch of SCC growth.) For the 3.444 inch edge crack case, the top 1.404 inches of the weld is considered to be removed to account for additional cracking on the top side of Bracket B. This configuration bounds Brackets A, B and D.
2. A 1.210 x 6/204 inch (a x c) corner crack with a 1.684 inch deep edge crack across the short axis of the lug. This configuration bounds Bracket C.

The effect of the two superposed cracks is treated by adding the Ki values calculated for each crack separately. Figure 4 shows the crack configurations for each case. Table 2 summarizes the calculated KJIEQ for each crack case and reports the allowable fracture toughness. All brackets are shown to possess sufficient structural margin for two cycles of operation as-is. 6.3 Limit Load Evaluation The limit load analysis is performed in the same manner as References [1, Section 7.7.1 and 2, Section 6.3]. The three crack cases analyzed, including which case corresponds to which bracket, are shown in Figure 3. The acceptance criteria used for this analysis are:

1. The ANSYS solution converges (meaning that the applied load can be supported by the net section and collapse does not occur),
2. The total strain does not exceed the minimum specified elongation at rupture of 40% [1, Section 4.6.5.1] for the bracket material,
3. The primary stress limits in the adjacent RPV shell are satisfied.

Figures 5 through 10 present contour plots of the Von Mises stress, Hydrostatic stress, and Von Mises Strain on the crack plane, for each crack case considered. Tables 2 through 7 present the maximum Primary Membrane plus Bending stress intensity in the RPV shell. Three paths were reviewed for each crack case and the membrane plus bending stress intensity reported in this calculation package is the largest of the three. The paths evaluated were located at the top of the bracket, the bottom of the bracket, and at the location where the stress intensity on the inside surface of the vessel, at the toe of the attachment weld, was the largest. Figure 11 shows the path locations for each crack case. Review of Figutres 5 through 10 reveals that all three crack cases for both service level A and service level B produced converged ANSYS solutions demonstrating that collapse did not occur. The elastic core remaining in the net section can be observed in each figure. Further, the maximum Von Mises strain for all cases is less than that the reported 40% elongation at rupture for this material [1]. Finally, File No.: 1400734.301 Page 8 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, Inc2 the results presented in Tables 3 through 8 reveal that the primary local membrane plus bending stress intensity in the RPV shell is less than the allowable limit for all crack cases. Thus, for the limit load analysis, all steam dryer support brackets are acceptable, as-is, for two additional cycles of operation. 6.4 Comparison of Friction Coefficients Since a friction factor of 0.65 is considered to be very conservative, a sensitivity run is performed to determine how much margin can be gained when a friction factor of 0.5 is used. Since the Case 2, service level B case produced the highest Von Mises strain, that case is re-analyzed using a friction factor of 0.5. Only a limit load analysis is performed since the limit load analysis is bounding over the LEFM analysis. As shown in Figure 12, the Von Mises strain is reduced from about 31% to about 14% using a friction factor of 0.5 instead of 0.65. This shows that there is additional margin to be gained for the current evaluation interval if a more realistic friction factor is used. However, an additional test run in ANSYS showed that when adding additional crack growth to the model, no significant amount of additional time could be added to the evaluation interval when a lower friction factor was used. Therefore, the factor of 0.65 is considered conservative but appropriate. 6.5 Computer Files Table 9 lists all computer files used for this analysis. All computer files are filed in the project files. 7.0 CONSERVATISMS Although the methodology utilized for this flaw evaluation is considered to be consistent with the guidance of ASME XI, IWB-3600 [4], it is acknowledged that the component evaluated in this analysis does not clearly fall under the existing flaw evaluation rules given in ASME XI, Appendix C. Further, there is currently lack of detailed data regarding the amplitude of the possible recirculation pump vane passing frequency (VPF) vibration at the steam dryer support brackets [2, Section 6.4]. Consequently, this section is included to clearly identify some of the conservatisms inherent in the methodology used for this evaluation.

1. The bounding, K-independent, NWC, SCC crack growth rate is applied for crack growth. This CGR was shown to predict an average crack growth larger than observed for the steam dryer support bracket indications between 2011 and 2013 by approximately a factor of 2 to 3 [2, Table 11].
2. A linear elastic fracture mechanics analysis is performed to assess the likelihood of unstable crack propagation in the bracket as opposed to a more complex but more appropriate and less conservative elastic-plastic fracture mechanics analysis. The fracture mechanics calculation is performed in addition to limit load because of the high constraint and resulting stress tri-axiality which might retard plastic flow sufficiently that failure would occur by fracture prior to collapse.

File No.: 1400734.301 Page 9 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, Inc.

8.0 CONCLUSION

S The results of the flaw evaluation documented in this report support the following conclusions:

1. The indications reported in the NMPl steam dryer support brackets 1-587A, 1-587B, 1-587C, and 1-587D are acceptable, as-is, for two additional cycles of operation.
2. There is considerable conservatism and margin built into the analysis. When a more realistic friction factor of 0.5 is used instead of the bounding 0.65 value, the Von Mises strain is approximately cut in half. This shows that there is additional margin to be gained for the current evaluation interval if a more realistic friction factor is used. However, an additional test run in ANSYS showed that when adding additional crack growth to the model, no significant amount of additional time could be gained by using a lower friction factor.

Considering the lack of detailed information regarding the amplitude of the possible recirculation pump VPF vibration and the appearance of active SCC growth in the steam dryer support brackets, SI recommends that Exelon:

1. Re-examine all four Steam dryer support brackets using both visual and UT methods during the next refueling outage to confirm that the behavior of the flaws remains bounded by the flaw growth evaluation documented in this report or to acquire the necessary inspection data to re-evaluate the flaws, as necessary.

File No.: 1400734.301 Revision: 0 Page 10 of 27 F0306-01R2

7jStructural Integrity Associates, Inc?

9.0 REFERENCES

1. SI Report 1100539.401, Revision 1, "Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation".
2. SI Calculation 1300596.30 1, Revision 0, "Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation - N1R22".
3. Mark's Standard Handbook for Mechanical Engineers, 11lh Edition.
4. American Society of Mechanical Engineers Boiler and Pressure Vessel Code:
a. Section XI, 2004 Ed., No Addenda.
b. Section XI, 2010 Ed., No Addenda.
5. RFO22 Inspection Photographs, SI File No. 1300596.204:
a. SD lug 50(A) top.jpg.
b. SD lug B top view.jpg.
c. SD Lug C top view.jpg.
d. SD Bracket 310 (D) top view.jpg
6. EPRI Letter 2012-024, "NRC Final Safety Evaluation of NDE Uncertainty." EPRI Proprietary.
7. EPRI Letter 2013-05 1, "New NDE Demonstration for UT Steam Dryer Support Bracket/Lug."
8. Design Input Request, Revision 1, SI File No. 1300596.200, UT Data.
9. Westinghouse Indication Notification Forms, SI File No. 1300596.202:
a. NMvPl-RFO-22-INF-13-05, Rev. 2, April 26, 2013
b. NMP1-RFO-22-INF-13-06, Rev. 0, April 26, 2013
c. NMP1-RFO-22-INF-13-07, Rev. 3, April 26, 2013
10. TR-105696-R1 1 (BWRVIP-03) Revision 11: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines. EPRI, Palo A lot, CA: 2008. 1016584. EPRI Proprietary.
11. BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals, EPRI Report 1016569, September 2008. EPRI Proprietary.
12. ANSYS Mechanical APDL and PrepPost, Release 14.5 (w/Service Pack 1), September 2012.

File No.: 1400734.301 Page 11 of 27 Revision: 0 F0306-01R2

Structural Integrity Associates, Inc? 1-587C 1-587 (Bune by -5I Note: When multiple wear marks are present, a conservative load application location is selected. Figure 1. RFO22 Inspection Photographs Showing Contact Locations on Top Surface of Support Brackets and Location of Load Application. File No.: 1400734.301 Revision: 0 Page 12 of 27 F0306-01R2

Structural Integrity Associates, IncJ Table 1: Summary of Steam Dryer Support Bracket Loads Load Service Level Value VDW =l5 kips DW A/BFllkp A H =5.0Okips Seismic (OBE & SSE) F2 = 5kips and Thermal BH = 16.25 kips B V~t*= 3.75 kips ________________F2

5 kips 343 llbs / 4 brackets

RIPD A/B857.75 lbs assumed negligible based FIV A/Bupon inspection results Fly AIBfrom bracket surfaces [1, ___Section 5.0]. Notes: 1. Service Level A = DW + Thermal + RIPD = SF(Vow +F 1 + F2 +RIPD) Service Level B = DW + Thermal + RIPD + Seismic (bounding of OBE and SSE) = SF (VDW + Vms + Fl + F2 + RIIPD + H)

2. Safety Factors (SFs) are taken from ASMIE Section XI [4]. For Service Level A, the SF is 2.7 for membrane stress and 2.3 for bending stress. For Service Level B, the SF is 2.4 for membrane stress and 2.0 for bending stress. These factors are used for the LEFM analysis, applying the appropriate SF to the appropriate stress. For the limit load analysis, bounding SFs of 2.7 for SLA and 2.4 for SLA applied to the loads in ANSYS.
3. RIPD loads are evaluated for Limit Load only and are oriented upward (opposite of DW).
4. VDW = Vertical force due to deadweight V~s= Vertical force due to seismic Fl1 = Friction force assumed to be caused by differential thermal expansion F2 = Friction force assumed to be caused by differential thermal expansion H = Horizontal force, including seismic File No.: 1400734.301 Revision: 0 Page 13 of 27 F0306-01R2

Structural Integrity Associates, Inc? I.01 ~Ie~I 61.91 1.70 _, 0.694 :*. 1-2.044 2*/ .04 l 0.24 2.50., 1-587A 1-587B UT EVT-1 Reported.... NDE Uncertainty__ End of Interval Size (SCC only)- Figure 2a. Overlay of RFO22 Inspection Data with NDE Uncertainty and 2 Cycles of SCC Growth File No.: 1400734.301 Revision: 0 Page 14 of 27 F0306-01R2

Structural Integrity Associates, Inc.* 2.50 8 1.13 1-587C 1-5 87D UT EVT-l Reported NDE Uncertainty__ End of Interval Size (SCC only)._ Figure 2b. Overlay of RFO22 Inspection Data with NDE Uncertainty and 2 Cycles of SCC Growth File No.: 1400734.301 Revision: 0 Page 15 of 27 F0306-01R2

~Structural Integrity Associates, Inc? 2.50 2.50 2.50 0.950 1.200 0.950_ ,//////.) C.) 1.210A CAS/1CAE/2CAE Bracket ABrceBBaktC (BondsBrcke D Fiue3 Edo ntra la/ofguain CnieedfrLmi odEvlain File No.: 1400734.301 Revision: 0 Page 16 of 27 F0306-01 R2

jjStructural Integrity Associates, Incj 2.50 1.210 + 2 + ~LEFM Crack Case 1 I Bounds Brackets A, B and D I ~ LEFM Crack Case 2 Bounds Bracket C Note: The element size used for the ANSYS analysis is 0.10 inches which results in a nodal dimensional accuracy of +/- 0.05 inches when defining the crack sizes in the FEM. Figure 4: Crack Cases Considered for LEFM Evaluation. File No.: 1400734.301 Revision: 0 Page 17 of 27 F0306-01R2

Structural Integrity Associates, lnc. Table 2: LEFM Results for Crack Cases Identified in Figure 4 Crack Case SL KIEQ, ks-n-K1, Aiowable, Acceptable ksi-in°5 (Y/N 78.28 + 33.00 = A 11.2 3.444" edge crack (with 1.404" removed) 112 with 0.950" edge crack 75.74 + 35.79 = B 111.53 150 4.63 + 33.51 = A 381 1.2 10" x 6.204" (a x c) corner crack381 combined with 1.684" edge crack 5.53 + 33.25 = B 38.78 File No.: 1400734.301 Revision: 0 Page 18 of 27 F0306-01R.2

~Structural Integrity Associates, Inc. 443g.3*74 139 , 3 232.t< 8 8042 386448 88<388* 53U87ORT 8<3-K3 FLA* EVALUATI A4 88<341 fl.4 11.21748 9321. 51 14.131 4*6.14.74 139341.3 23233,1 448P3 578444 287Y41< 378<2<2<T 899818 F1.A8 87WAL347TI 28<953 4 904. I-a)Right side view of the FEM showing Von Mises stress. Displacement scaling = 1 5X. b)Von Mises stress on crack plane, looking toward RPV surface. 3,,. AN~8~ AE~fl 8,80*.11<39 1<0836L <8<43<O -4*7t43<.2i,4 ]"!213.~l+ -4<381.4 -8t38 .5 <42"5 41*. 83"*4 10*1 8.81 207<3< 2.3EP 838<7OR 84.971<3 P1.W 8-AL9A7133N 8881I 878.81 2876 334<32<7 9988 8<-3.0 0 W3Wt<<84717T8 .*03017 c)Hydrostatic pressure on crack plane, looking d)Von Mises Strain on crack plane, looking toward toward RPV surface. JRPV surface. Figure 5: Limit Load Results for Steam Dryer Support Bracket Crack Case 1 -Service Level A - Bounds 1-587A, 1-587D - 2 Cycle SCC Growth. Table 3: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587A, 1-587D, Service Level A. Path P,+P3, Allowable, ________psi 1.5S=., psi Peak 15,780 J 40,050 File No.: 1400734.301 Revision: 0 Page 19 of 27 F0306-01R2

Structural Integrity Associates, Inc. 0m

4.30*20
06.

os 65401 OTIAF DOLED VUPPLKT BPRACKT FLAW/ !VLUATIU* $5;0 AV 03 534 4 043. O*tDO OTEA< DDYER OO0PUO*T BALD*'r FLA EV/ALI&TI(UI a)Right side view of the FEM showing Von Mises b)Von Mises stress on crack plane, looking toward stress. Displacement scaling -- 15X. RPV surface. Sue.4 0305.4 toward RPVsurface.1RV su1fa0e Figure 6: Limit Load Results for Steam Dryer Support Bracket Crack Case 1 -Service Level B - Bounds 1-587A, 1-587D - 2 Cycles SCC Growth. Table 4: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587A, 1-587D, Service Level B. Path Pm+Pb, Allowable, ________psi 1.5S.,pi Peak 16,420 40,050 File No.: 1400734.301 Revision: 0 Page 20 of 27 F0306-01 R2

VStructural Integrity Associates, In02: 97.4584 8594.72 28999.2 4422.62 D*'fi 34786.8KAr*E F 23972.!AT 9931 23; AN)~Y~ 28793.4 39 4 7. 12".2 Ž83 9892.9' 9 348. 9289 2 287! '935593 4t94l** 42Ž, SF .M RY} 23P* 24398.2E - 0933LAT~f a)Right side view of the FEM showing Von Mises stress. Displacement scaling = 1 5X. b)Von Mises stress on crack plane, looking toward RPV surface. AN~Y~ AI6~Y~' 721*S5 19963 999 .4299 36 793223 294994

  • 124 29949 2.

22920929 69.82228 22.88 59763.2Ar2935 g791*.*

9%42.*

42822 572F828 D9199 93299597 536:989 F2949 929AL02A1214

  • 2i.*5

,028527 c)Hydrostatic pressure on crack plane, looking toward RPV surface. d)Von Mises Strain on crack plane, looking toward RPV surface. Figure 7: Limit Load Results for Steam Dryer Support Bracket Crack Case 2 -Service Level A - Bounds 1-587B - 2 Cycles SCC Growth. Table 5: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587B, Service Level A. File No.: 1400734.301 Revision: 0 Page 21 of 27 F0306-01 R2

Structural Integrity Associates, IncY 35.5090 9Ž00,04 10443.' 4633.37 13433.4 23422 44429 Sa [TENO 99.009 33904?BACXZT 400W SVALOJATIOX AN*T¢ 5933399 44.39 44.93945.23 14.510445.0 23* 4.5****

  • 4.

1*49 STENO 093'ED 0001905T 9991*099T 7LAW RV*ALAT*OOC a)Right side view of the FEM showing Von Mises stress. Displacement scaling = 15X. b)Von Mises stress on crack plane, looking toward RPV surface. .0'+0 AII~Ybi 7000100 9Ž42 0,1 2 9.... 3 (*90 99II4I 94099 00T9440 7D30D 3L499,T 49W009ET 4020r 409AL4AT40445>99950DOE 09000 9202T402 f00T 4.00.. ~ 9 I¢*I.*?ZC*H Dr, YI*. SU.*eK'* *-',AC/<Ir't FIAW Ir';iLLOATIO* .2S*44

    • )6855 c)Hydrostatic pressure on crack plane, looking toward RPV surface.

d)Von Mises Strain on crack plane, looking toward RPV surface. Figure 8: Limit Load Results for Steam Dryer Support Bracket Crack Case 2 -Service Level B - Bounds 1-587B - 2 Cycles SCC Growth. Table 6: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587B, Service Level B. Path Pm+Pb, Allowable, __________psi 1.5S*, psi Peak 16,210 40,050 File No.: 1400734.301 Revision: 0 Page 22 of 27 F0306-01R2

Structural Integrity Associates, Inc' 5063 36333u SCSI -4.16 ,Ns* TOi STEA 06E4 5UP 1WR2E595~t FLAW EVAL AT 43,695 967.61 13l*.* 2 93 4 57. 49 i.6 344 3.3 24133.

  • 94 43405.

419?,TERM Eu OF 3UFFO3T B06i2FT FLAW AL'iASUAI3N a)Right side view of the FEM showing Von Mises stress. Displacement scaling = 15X. b)Von Mises stress on crack plane, looking toward RPV surface. .. ~C1-19 SC SURE?

  • PKE IAV*)

DMX -,0!I*65 SSZ "4:*0*.% Cii 're3F<~u63 559CR. 5963P 170204 FF330? SUP1ORT FROCKS? FLAW EVALUA3>304 TN? 4 30T41 FRYE? 30FF33T IF,.2E1 FLAu EVAI3IA3I 235 c)Hydrostatic pressure on crack plane, looking toward RPV surface. d)Von Mises Strain on crack plane, looking toward RPV surface. Figure 9: Limit Load Results for Steam Dryer Support Bracket Crack Case 3 -Service Level A - Bounds 1-587C - 2 Cycles SCC Growth. Table 7: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587C, Service Level A. Path Pm+Pb, Allowable, ,________psi 1.5S., psi Peak 15,910 40,050 File No.: 1400734.301 Revision: 0 Page 23 of 27 F0306-01 R2

StructuraliIntegrity Associates, Inc.* ANSY! AN5Y <*.2441 12*3 34 (32.4 i!415206<0.4 g6, 441124144344 <3<441+ 4<3403 SJP F 3*AC* T J F 4 VALBJAT<04 N

  • ,allZ*4 33<3<

43 3 4< '<.2341 1,3332.4 23<44.113.7< <<<<<.34 <4431.3 .3<3<39.4 43*1 343444< 34.33+ <3<33134.1 444+04<4< FLAW 443A33A3'3334 413433.3 411<3< <<<3M. 431.4,3 a)Right side view of the FEM showing Von Mises stress. Displacement scaling = 1 5X. b)Von Mises stress on crack plane, looking toward RPV surface.

  • Lq* =4
  • z =5c552,6 RNt) 441 -.

243 <7<4<44 ANWI) .3<444.1 44<4.44 2<30 444413 <4<4+41 4<3314< <34<3<344? 4<1+064< FLAW 40A<.3AT<344 4444 3 3 44444 <3 SUP 4<4+324444<3 FLAW LVXLUAT1344< .U224* c)Hydrostatic pressure on crack plane, looking toward RPV surface. d)Von Mises Strain on crack plane, looking toward RPV surface. Figure 10: Limit Load Results for Steam Dryer Support Bracket Crack Case 3 -Service Level B - Bounds 1-587C - 2 Cycles SCC Growth. Table 8: ASME B&PV Code Primary Local Membrane + Bending Stress Check, RPV Shell, Steam Dryer Support Bracket 1-587C, Service Level B. Pat Pm+Pb, Allowable, Pahpsi 1.5S,., psi Peak j 16,370 40,050 File No.: 1400734.301 Revision: 0 Page 24 of 27 F0306-01R2

~jStructural Integrity Associates, Inc.* DN)..0117C) I11. 9748 321.61 18631 4.56.74 13976.3 23205.% 54)01 11TEAM 06066 SUFIUIK '7RACKET FlAW EVALUAT1ON A~4sn Case 1 SLA~ ONOUDD.l 4501 .4.5CaseL 1 2*94*.6 37250.I 32595.3 41904.9 106.1 10539.4 27302.7 34S 4f4. 54)02171T629 160605 IUPI?36? 066K4)T )'AW EVALUATION PATSI Case 2 SLA SN) 4X 505600u ANSYh SLB! U 34550 72 9 0 934 10440." 46*34. 07 3039 4 3042 16.460) 4444.76 09079.4 20747.4 10747.7 4)04.41 14406.2 64231.1 44511.1 43140.0 N'1 *1040 ANVilS NUITXNYSI NAAOINZT 7S.AW NSAD¶IAY7NSN 2744t3.2 34045.0 32244.0 41447.5 Case 3 055.011")06) SLA 43.697 5 9679.61 19011.6

  • 99i. 4 396987.4 4f641.41 14497.6 24133.6 33769.4 43405.

54101I TUAMN216 1DRYER 7 SUPPORT 5RA .E LAWVAL.UA70)35 NODA 00-1 /L 4T054-Si STEP IAt; 1137) AN5Y* Case 3 SLB 1005 74.2041 10342.4 200305.1 30200.4 44104.0 5207.74 14445.5 24744.4 94047.7 44714.4 013421 ISLAM 00000 0ASYULUN 07*000? 70,443 10D0AT.D14 Figure 11: Orientation of Paths to Extract Linearized Stresses in RPV Shell. File No.: 1400734.301 Revision: 0 Page 25 of 27 F0306-01R2

~~j.StructuraI Integrity Associates, Inc.* ANSY5 11l4i NODA.L SOLUTION STE 2=1 SUB =8 TIMEJ=1 EPTOEQY (AVG) RSYS=0 DMX =.094609 SMNJ =.175E-05 SMX =. 306055 Case 2, SLB Friction =0.65 Strain = 30.6% .175E-05 .068014 .136026 .034008 .1.0202 .170032 NMPI STEAM DRYER SUPPORT BRACKET FLAW EVALUATION .20 40386 .27205 .306055 .238044 ANSYS NODAL SOLUTION RIAA STE 2=1 SUB =4 TIME=I EPTOEQV (AVG) D =05185 SMN =.193E-05 Sr.V =. 139336 .193E-05 .030965 .061828 .092891 .123854 .015483 .046447 .07741 .108373 .139336 NMPI STEAM DRYER SUPPORT BRACKET FLAW EVALUATION Case 2, SLB Friction = 0.5 Strain = 13.9% rvice Level B Figure 12: Comparison of Strain for Crack Case 2, Sei File No.: 1400734.301 Revision: 0 Page 26 of 27 F0306-01R2

Structural Integrity Associates, Inc. Table 9: Summary of Project Computer Files Filename Program Purpose Contains LEFM calculations for bracket LEFMof Backe-SL~xmc MatCADflaw stability for service level A loads Contains LEFM calculations for bracket LEFMof Backe-SL~xmc MatCADflaw stability for service level B loads Input file for limit load analysis of NMP1l_SB_BracketA-SLA.inp ANSYS crack case 1 (bracket A), service level A Input file for limit load analysis of NMP1l_SB_BracketA-SLB.inp ANSYS crack case 1 (bracket A), service level B Input file for limit load analysis of NMP1_SBBracketB-SLA.inp ANSYS crack case 2 (bracket B), service level A NMP1SBBackeB-SL~mpInput file for limit load analysis of NMPISBracktB-LB~ip ASYScrack case 2 (bracket B), service level B Input file for limit load analysis of NMP1_SBBracketC-SLA.inp ANSYS crack case 3 (bracket C), service level NMP1SBBackeC-SL~inpInput file for limit load analysis of NMP1SB racktC-LB~ip ASYScrack case 3 (bracket C), service level B Input file for limit load analysis of NMP1_SBBracketB-SLB-P5.inp ANSYS crack case 2 (bracket B), service level B using friction factor of 0.5 Input file to extract linearized stresses LinearCrack#_SL$.mac ANSYS in the vessel wall, where # is crack case 1, 2 or 3 and $ is service level A or B output file containing linearized stresses in the vessel wall, where # is crack case NM~lSDBR-P-rack-SL$lin1, 2 or 3 and $ is service level A (1) or S(2) File No.: 1400734.301 Revision: 0 Page 27 of 27 F0306-01R2

Structural Integrity Associates, Inc.* Appendix A STEAM DRYER SUPPORT BRACKET LEFM EVALUATION File No.: 1400734.301 Revision: 0 Page A-i of A-27 F0306-01!R2

Structulral Integrily Associates, IncY SERVICE LEVEL A V 5; ~qft. l J For the configuration shown above the stress intensity factor at the crack plane is determined by superposition of the following LEFM solutions found in The Stress Analysis of Cracks:

1. Edge cracked finite width plate subjected to in plane and out of plane shear stresses (pg. 73)
2. Semi-infinite 90 degree plate intersection with edge crack at intersection subjected to axial force, moment, and membrane stress (pg. 307).

From pg. 73: KU,.,soj ,(W* oo**-.-F, U .,() b '{lraX*2b} File No.: 1400734.301 Revision: 0 Page A-2 of A-27 F0306-0O! R2

Structural Integrity Associates, Inc.* KI-q"I-{.c-1a(A) + -*.(A) + FmAJ KII -- i*"a'cr.FIkcr(A) + -- "FIlp(A) + Ž1 F~lm(A))W A(a,W) -- a FIo-(A) =-,L* -.0 18 + 0.069-e 2{i] FJIao(A) = A*-* .5 0.067-e S.. -AI FHp(A) = 1 [ 9 + 0.6"-A - 0.6-e -A 3 JX-(1-A)2 Fllp(A) = 1 .[0.126- 024-A - 0.023-(1 - A:*j FIme(A) - 11.005 - 0.72-,.{AI) 3 FIm()- 1 -o + (,- A)(.(o7 - o.2 + o.SA2)] File No.: 1400734.301 Revision: 0 Page A-3 of A-27 F0306-01R2

Structural lntegrity Associates, IncY For Hoop orientation (i.e. circumferential orientation in RPV.) i"= 0,I..3 aj :=- in Range of crack sizes to evaluate. 1.211 W:= 2* in bw W03 15000 2.5-8 Tr = 7.50 S(500.-1+ 1500-.2.5)-(1252 + 42)0. 12 TIl = 1521 1.122 - 0.561-I- + 0.085- - I+0.- FII.*a-1-- b 1/'.161*[=l1.,82i KIIIi :=2 7T-FI Ei 1 4136.2 1.0467 k1.t118 I Flfl:= 2-b (~Jra. I File No.: 1400734.301 Revision: 0 Page A-4 of A-27 F0306-01R2

Structural Integrity Associates, lnc.* Killi.: 2.7T1 4 -i-FUli-213.44 1000-2 oa-7.125 10000 P:= 8 k 9184) (Pressure stress) (Force per unit thickness) a= 14978 P = 1250 M = 4844 psi lb in lb-in in 3250-2.5 + 5000-1.2.5 +i 9750-2.5 8 (Moment per unit thickness) F ~ ~f:=-.01 + 0.069-e l.{~!) Fi-:= 1~A1-.5-o.o6 ?-.ekl--J] Fifo-0-027 0.0239 0o.156.) (1-824'l Ik2 764) (0-145t Flp = lo0035l 00o~21) Flpi 1 f0.79 + 0.624-A1 - 0.062-e 11..j

  • (-

A*)2 File No.: 1400734.301 Revision: 0 Page A-5 of A-27 F0306-01 R2

Structural Integrity Associates, Inc.* FjKir.'2.5 -0.2e 6.288' / 6653/ Fi =~o I -0o31s>] F*.(, _Ai)2 '-0.743)] 2 2.71 23__MM.i KIi = -" -T7cr'Fko + ----- FIip.+ -¢2m. r23372'] ,,37165 j 112749 I \\9934) psi-4;i KI_2i.-= * ~{.7o"FIkTi + +-FII.i + J w I ? An equivalent KI may be given by:

=03 i~~

+ (u +Kii_2ij2 + 0.5n)2 1330001 K~eq- =40037/ t*41539) File No.: 1400734.301 Revision: 0 Page A-6 of A-27 FO306-01R2

Structural Integrity Associates, inc.* ~fvw -

    • P*VVV 46000 KIeq QI2 32000 180001 40001................................................

- "".s 0.85 0.89 0.94 0.98 1.03 1.07 1.12 1.16 1.21 1.25 Using a solution for a quarter elliptical crack in a finite body subjected to remote tension and bending loads (Raju and Newman): a :=1.210-in c:"= 6.204-in al = 0.195 C c-ff 0.775 g-in a 2 ffi 0A84 Using the a/c=0.2 graph in Figure 7 of NASA Technical Memorandum 85793 gives a maximum Fc at the deepest point. This value is approximnately 1.7. At the surface Fc would be approximaely 0.8. From Figure 8, using the same crude interpolation gives a FcHc=-0.7 at the surface and -0.75 at the deepest point. 1 ,.65 Q= 1.o99 File No.: 1400734.301 Revision: 0 Page A-7 of A-27 FO306-01R2

Structural Integrity Associates, Inc.e Remote bending stress is given as: Remote tension stress is given as: 6-M 6M lb Sb -.psi Sb>:= b.,2 4.2Y5 z& lb Sb= 1163-- .2 mn lb St=- 62.5-- .2 ttn P St = 2-b-t P lb St:-= 2.5- . 2 a Ksurface (St-0.8 + 0.75-Sb)-2.7 it-- Q a Kdeep := (St-li + 0.7-Sb)-2.7 i~- Q Ksurfae = lb 0.5n: .2. Kdee = 62o.*.! =°0. .2. In Note that the corner crack case gives a KI that is -10 smaller than the edge crack (5 versus 50). This solution does not consider torsional loading or shear and may be at the edges of the applicability of c/b; however, it gives an estimate of the benefit of more accurately treating the corner crack configuration. For Axial orientation (i~e. longitudinal axis of RPV) b -= W' a w Wv 2.5-8 in Range of crack sizes evaluated in (0.125) o.43 ) T= 750 " -=(5000-1 + 15000-2.5)-(1.252 + 42)0. 1(g2.5 Ti = 1521 File No.: 1400734.301 Revision: 0 Page A-8 of A-27 F0306-01R2

Structural Integrity Associates, lnc~ -~ 3 1.122 - + 0.085{2) + 0.180-~~~ RI. := a-I 1-- b 2-b ira.I FIlL I l.126""i t1.13o715 k,.037) (1,o7*, 11019 I Fifi ,:o I 10441,, L14717) 213.44 1000-2 10000 2-(Pressure stress) (Force per unit thickness) ar = 7489 P = 4000 psi lb In lb-in in 9750-5.5 + 15000-2.25 + 3250-1 M : AW'° 2.5 (Moment per unit thickness) M = 36250 1 0 'A.

12.

A. L.ois + o.06-e 1Ai-*j1 F~Icr 0.078"* S0.027 00o~21) Fr=0231 0.179) File No.: 1400734.301 Revision: 0 Page A-9 of A-27 F0306-01 R2

Structural Integrity Associates, Inc.* "i. = 1379 + 0.624-A. - 0.062-e 1. Fire. := 1 [o26- 04A1-9"03.1*A)5 IFm.[2t15 .2-(1.541 '/ 0o213l ko.o0.76) 6.o24l

  • -6027,/

F.7. o I (0356")j FJ-(,= - 0.2& (-A)f057 02A -(o_2j 02 f2 2.7P 2.3M I Fi.*.2.7u.F-o +---Ip + *- ~~ 20901" S42032) (14528')

  • ,9820)j psi-2 2.7P 2.3M -F "1'

U_2*.* : J.j7a.-* + -. Hlp+ w2 An equivalent KI may be givn by: v.= 03 KU 2 ( 1._*+K *2)2 1 0.5 k48939) File No.: 1400734.301 Revision: 0 Page A-l10 of A-27 F0306-01 R2

Structural Integrity Associates, Inc' 47600 KU_1352oo)~ KU_2 KI 22S00 10410 - 2000 1.3 1.5 1.8 2 23 2.5 2.8 3 33 . ].5 a Since Bracket B has through wall flaws on top and bottom, assume top flaw area is removed for shear stress calculation. W 6596 in b =W a (0.1s2"j k~o~s22) Tr = 909.642 15000 v2.5-6.596 3"*.'= (5000.1 + 1500-2).3)(1.252 + 42)0. 12 "di = 2605 File No.: 1400734.301 Revision: 0 Page A-11 of A-27 F0306-01R2

Sj~tructural Integrity Associates, Inc? 1 a. b 1.129Nj

1..27)

(4913")j 8135 k 10259) S1.143) k,2645o) 7r 8. 2-b I FlU1 := ~~.tat\\ 2-b, I 213.44 1000-I 2 m: 2-7.125 (Pressure 10000 (Force pet 2.5 9750-5.5 + 15000-2.25 + 3250-1 M* ~2.5 stress) runit thickness) C,- = 7489 P = 4000 M = 36250 psi lb in Ib-in in (Moment per unit thickness) 1--Aii. 0ig +0.o69.,

  • ,t-Ai J Fcri A.

1~r = .16 007-0.06 Nj{0.032I (0337"j 0.1,99/ \\o0.149) File No.: 1400734.301 Revision: 0 Page A-12 of A-27 F0306-.01!R2

~Structural Integrity Associates, Inc.* Fi.: 1 0t379 + 0.624-A. - 0.062-e t.-* - 2 Flip -o.,26-o0.2A.- oo.- " 1ie [.005 - 0.72-e Jxu 1.533" L2.953.) o.261 L4.799 x io-) =/6-°l6/ 8 s4) 0.213 Fl.:-,_.[-o2 + (1,- A*)4[o.577-o2. + o.8(A)2j 0213i:,:

  • .(, :,)
  • -.0.53 (2

2.7P 2.3M Fm KUI 2i.:= h-i2.T7-FIIai + -FlIip +

  • - -im I

I ".2 {27374* Ki= I,,* (13549'j 1,2148 k, 4859 ) 43959I ,.78276) psi-*/* An equivalent KI may be given by: ! '= 0.3 Kfoeq*.. [( + (K -,, +,2 1)2 + _:_L.,.(IIl°),_,, psi-4* File No.: 1400734.301 Revision: 0 Page A-13 of A-27 F0306-0 ! !

Structural Integrity Associates, Inc. The static fracture toughness for unirradiated stainless steel is taken from BWRVIP-76 as 150 ksi-inA0.5. The required structural factors for Level N*B conditions have already been accounted for in the equations above. Therefore, the allowable fracture toughness for stainless steel is given as: KIallowable =-150 ksi-m0"5 Considering a flaw oriented on either axis of the support bracket the applied stress intensity factor is less than the allowable fracture toughness. File No.: 1400734.301 Revision: 0 Page A-14 of A-27 F0306-01 R2

Structural Integrity Associates, Inc.* SERVICE LEVEL B V. af,

  • 1'i
  • g For the configuration shown above the stress intensity factor at the crack plane is determined by superposition of the following LEFM solutions found in The Stress Analysis of Cracks:
1. Edge cracked finite width plate subjected to in plane and out of plane shear stresses (pg~ 73)
2. Semi-infinite 90 degree plate intersection with edge crack at intersection subjected to axial force, moment, and membrane stress (pg. 307).

From pg 73, 1(1-- T-*-f-FU ~x+~ (aYe O.56l.fl~ + 0085.!'.! 180--I 1.122-k~b) kbJ FII ab Kill = r~-.~F.Fffl 2b i~a FIil -- tan - ~a 2b File No.: 1400734.301 Revision: 0 Page A-15 of A-27 F0306-01R2

~Structural Integrity Associates, Inc? K1,W = -- a()+ -Fm() Kf(A)= A-.S + 0.F069-e +.F-mA)J FI~{cr(A

  • F 56 k0(67-FIp(A) -

-L379 + 0.624-A - 0.062-c I-AJ F ,*-A)= [012 6 2-X2-1-A F*m(A) = 1110056-o.7.A-c oo-3 FIm(A) = 1_I-02 + 91 A) 4 ti7-o~ .4)

  1. %f -(iA)2 File No.: 1400734.301 Revision: 0 Page A-16 of A-27 F0306-01R2

Structural Integrity Associates, Inc.*' For Hoop orientation (i.e. circumferential orientation in RPV) i:ff 0,1.. 3 I' 11 W :- 2.5 b:=W A. "== - 18750 2.5-8 1i1 Range of crack sizes to evaluate, in (0321 038 1 0.= I "r = 937-5 I" =(16250-1 + 18750-2-5)-(I.252 + 42)0-12 Tir = 2259 1.122- 0-561]-1a + 0.0ss]- + j01s0 b 1.161 1182 I FLI = I 124 1252) K.IIIi := 2.4"r-*-FIIi 4140 = l4595.81 5441 1.0671 FIJI s I Fill.:- 2-b ira. ira. 2-b I File No.: 1400734.301 Revision: 0 Page A-17 of A-27 F0306-01 R2

jjStructural Integrity Associates, Inc.' KIlli := 2.4"rl-*-Fl]Ii r11824 k\\12125) a= 14978 213.44 1000-* 2 o" '== 7.125 (Pressure stress) psi 10000 (Force per unit thickness) M 3250-2.5 + 16250-1.25 + 9750-2.5 (Mmnpeuithcks) 8 P = 1250 M = 6602 lb im lb-rn in 1 -A-li - 12"5"j I-j*-II Fo-i := LO.01 + 0.069-e Fifoia:= 1-L0.156 -0.067-e

  • 'lA"J 0.027*

0l023 F ouo= I 0019o-0018) ! o226'j 2.0147 k2.764) ( 0-145" Flp = l0.0351 k0.021) "= 079+ 0.624-A. - 0.062-e 1.jj Fl~ip."16 2-. .2.1-A~ 13 K File No.: 1400734.301 Revision: 0 Page A-18 of A-27 F0306-01!R2

~jStructural Integrity Associates, lnc.? F.:= .L0 - 0.72-l-1 l 1 3 62gg8 [ 6.653 1 Fi = oI FJ~m + 1 -A~).[0577-02A~+ 08(A21 y-031]"

  • ,-~~- A

, *=+I,-2,-o-*, ,*) =**~ r.24 .f~ 2_4P 2.0MFii w w An equivalent KI may be given by:

=-03 (26039"/

129954 KI= 1 psi-j* (12086'* 80

  • 53 )

l35786 KIteq= I*0

  • .45958) psi4i~i File No.: 1400734.301 Revision: 0 Page A-19 of A-27 F0306-0O! R2

~jj~structurai Integrity Associates, Inc~ Structural teg ty ssoc ates, c. O~JAd K*Il 32000 KU_2 K.Il 1OO 40001 -I00(.s 0.85 0.89 0.94 0.98 1.03 1.07 1.12 1.16 1.21 1.25 Using a solution for a quarter elliptical crack in a finite body subjected to remote tension and bending loads (Raju and Newman): K=-"(St +H-Sb)-2.4 -FJ a I= .210-m c := 6204-ti a- = 0.195 C C -= 03775 8-m a 0.484 2.5-i Using the a/c=0.2 graph in Figure 7 of NASA Technical Memorandum 85793 gives a maximum Fc at the deepest point. This value is approximately 1.7. At the surface Fc would be approximately 0.8. From Figure 8, using the same crude interpolation gives a FcHc=~0.7 at the surface and -0.75 at the deepest point. -- 1.65 Q= 1.099 Revision: 0 Page A-20 of A-27 FO306-OI 12

~jStructural lntegrity Associates, Inc? Remote bending stress is given as: Remote tension stress is given as: 6-M 6-M lb Sb)= -- psi S bt b-t2 4-2.52 in2 P P lb St= St=--- 2-b-t 2.5-8. 2 lb -0.5 K~suif'ace = 5528-- -in Kdee = 5425--i in lb Sb = 1584-- tin lb St = 62.5-- in a Ksuiface (St-0.8 + 0.75.Sb).2.4 '~r--Q a Kdeep (SF1.7 + 0.7-Sb~-2.4 ~-- Q Note that the corner crack case gives a KI that is -'10 smaller than the edge crack (5 versus 50). This solution does not consider torsional loading or shear and may be at the edges of the applicability of c/b; however, it gives an estimate of the benefit of more accurately treating the corner crack configuration. For Axial orientation (i.e. longitudinal axis of RPV) I IL

=1.684 I "I W= S b

W a w 187501 T : N.'* 2.5-8 in Range of crack sizes evaluated m (0.125 '

  • , 043 )

T = 937.5 AWh + 2.5.8) 12 "rI = 2259 File No.: 1400734.301 Revision: 0 Page A-2 1 of A-27 F0306-01R2

S~tructu~ral Integrity Associates, Inc? 1.122 - 0.561-j + O.Oss5- + Ol b K*l= 2.4T 7 .. F.Ii IIi= a 2-b )

12&

158791 KI 89 304 (Lopoi I 1019oI 213.44 1000., 2 Mv, 2-7.125 10000 M:A 2..5 (Pressure stress) (Force per unit thickness) a- = 7489 P = 4000 psi lb lb-in in 9750-5.5 + 18750-2.25 + 3250-1 2.5 (Moment per unit thickness) M = 39625 1-AI - 12.5.] pil. F~o~i

=

-o018 + 0.069-e F~kri.= A.-L.56 - 0.067-e ~i 0.078" 0.027 0.29 1 FIao" =

0.

I 0.131 File No.: 1400734.301 Revision: 0 Page A-22 of A-27 F0306-01 R2

VStructural Integrity Associates, Inc.* 2 FI~ 1 f0.379 + 0.624-A. - 0.062-e "1-Ai1 - A o,-

  • .-)..t-2 FIIPi 1=

.[3 602.Ai.23( i 3. 1.541) 26.247) Fl~p = l°7 ~0.026" A~) k-o.57 KI f2 4 2.4cFk.+2P +2.OM.ien KUi 2. Wi-.4a"FJIa. +-.,FPi + 0 Flp Fim (19467") \\39239)

  • ,8579),

psi-,jm psi-'4'* An equivalent KI may be given by: iv -= 03 ,<-,eq---[(K*)2 + (K-,,+K 2-1f -L(m)2]°,_ 3t3249/I 48843) psi-*/ File No.: 1400734.301 Revision: 0 Page A-23 of A-27 F0306-01R2

Structural Integrity Associates, lnc. utJKIUu 47600 KIeq Kil 352oo Kil2 K2 2 8 OO i 10400 - 20001-1.3 1.5 1.8 2 2.3 2.5 2.8 3 3.3 3.5 Since Bracket B has through wall flaws on top and bottom, assume top flaw area is removed for shear stress calculation. W-.= 6.596 A6.J.* in a 18750 S2.5-6.596 __I.6.59.2.5+ 2.5-6.5963) 12 I 0.252"I ILoi22) Tr = 1.137 x I03 Til = 3869 File No.: 1400734.301 Revision: 0 Page A-24 of A-27 FO306-01R2

VStructural Integrity Associates, lnc.* 1.2- 0.561- ; + 0.0S5-t + 0.1g0-~ b KiIi

=2.4T-1

-FIil 1.129"I {7181 ri =l9039 11t399) 1t.143) 1t6617) l 21961tl AI= 27757/ 34*920) a. 2-b FUI.=-- 1 ~ ~2-b) 1 Killi := 2A~.4;rI-.FIm 213.44 2 a-':= ,w* 2.-7.125 10000 AM 2.5 (Pressure stress) (Force per unit thickness) cr = 7489 P = 4000 M = 36250 psi lb in lb-in in 9750-5.5 + 15000-2.25 + 3250-1 M= *t,* 2.5 (Moment per unit thickness) I 12.5-i ) A~ri .1=-_1.Lo 1o + 0.069-e 10-,. -Ni F Ia. -A 1[ 6 0.067-e

  • -i FlieA.

0.06] 0.032I (0337')

  • ,0.149)

File No.: 1400734.301 Revision: 0 Page A-25 of A-27 F0306-01 R2

jjStructural Integrity Associates, Inc2? F - 12( Ftp. -= 1 39+ 0.624-A. - 0.062-ej Fllip := 1 .[0.12 - 0.24-Ai - 0.023-(l -Ai5 II - A ) (1.33 '* 1k2.953) ( 0261 Fl.799 0.10"94 0.0183 >k i.4) 0.213 " Fil.:: .F-0o22+ 11,- A -[.1.F.57-o02.+ o.I:] * :?,

  • 2i*

4P* 20M**p '\\* I An equivalent KI may be given by: -= 0.3 23931) \\61194)

- 12030 10811 KU_2=3 psi-.'i*

File No.: 1400734.301 Revision: 0 Page A-26 of A-27 F0306-01!R2

Structural Integrity Associates, Inc.* The static fracture toughness for unirradiated stainless steel is taken from BWRVIP-76 as 150 ksi-inAO.5. The required structural factors for Level NfB conditions have already been accounted for in the equations above. Therefore, the allowable fracture toughness for stainless steel is given as: KI allowable :=150 ksi-in0* Considering a flaw oriented on either axis of the support bracket the applied stress intensity factor is less than the allowable fracture toughness. File No.: 1400734.301 Revision: 0 Page A-27 of A-27 F0306-01R2 EPRI affidavit to request withholding of proprietary information contained in "Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation -2014"

SI ELEcTRIC PowER SRESEARCH INSTITUTE NEIL WlLMSHURST Vice President andl Chief Nuclear Officer Ref. EPRI Project Number 669 May 19, 2015 Document Control Desk Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Request for Withholding of the following Proprietary Information Included in: "Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation-2014" included in Structural Integrity Associates, Inc. Report on Project "NMP1 Steam Dryer Support Bracket Flaw Evaluation" for Plant Nine Mile Point Nuclear Station, Unit 1. File No: 1400734.301 To Whom It May Concern: This is a request under 10 C.F.R. §2.390(a)(4) that the U.S. Nuclear Regulatory Commission ("NRC") withhold from public disclosure the report identified in the enclosed Affidavit consisting of the proprietary information owned by Electric Power Research Institute, Inc. ("EPRI") identified in the attached report. Proprietary and non-proprietary versions of the ReDort and the Affidavit in support of this request are enclosed. EPRI desires to disclose the Proprietary Information in confidence to assist the NRC review of the enclosed submittal to the NRC by Exelon. The Proprietary Information is not to be divulged to anyone outside of the NRC or to any of its contractors, nor shall any copies be made of the Proprietary Information provided herein. EPRI welcomes any discussions and/or questions relating to the information enclosed. If you have any questions about the legal aspects of this request for withholding, please do not hesitate to contact me at (704) 595-2732. Questions on the content of the Report should be directed to Andy McGehee of EPRI at (704) 502-6440. Sincerely, .. / Attachment(s) c: Sheldon Stuchell, NRC (sheldon.stuchell@nrc.gov) Together... Shaping the Future of Electricity 1300 West W.T. Harris Boulevard, Charlotte, NC 28262-8550 USA

  • 704.595.2732
  • Mobile 704.490.2653
  • nwilmshurst@epri.com

~*~*~* ESEARCH INSTITUTE AFFIDAVIT RE: Request for Withholding of the Following Proprietary Information Included In: "Nine Mile Point Unit 1 Steam Dryer Support Bracket Flaw Evaluation-2014" included in Structural Integrity Associates, Inc. Report on Project "NMP1 Steam Dryer Support Bracket Flaw Evaluation" for Plant Nine Mile Point Nuclear Station, Unit 1. File No: 1400734.301 I, Neil Wilmshurst, being duly sworn, depose and state as follows: I am the Vice President and Chief Nuclear Officer at Electric Power Research Institute, Inc. whose principal office is located at 1300 W WT Harris Blvd, Charlotte, NC. ("EPRr') and I have been specifically delegated responsibility for the above-listed report that contains EPRI Proprietary Information that is sought under this Affidavit to be withheld "Proprietary Information". I am authorized to apply to the U.S. Nuclear Regulatory Commission ("NRC") for the withholding of the Proprietary Information on behalf of EPRI. EPRI Proprietary Information is identified in the above referenced report by double brackets. An example of such identification is as follows: ((This sentence is an example.{E}}} Tables containing EPRI Proprietary Information are identified with double brackets before and after the object. In each case, the superscript notation {E} refers to this affidavit as the basis for the proprietary determination. EPRI requests that the Proprietary Information be withheld from the public on the following bases: Withholding Based Upon Privileqed And Confidential Trade Secrets Or Commercial Or Financial Information (see e..q., 10 C.F.R. § 2.390(a)(4):

a.

The Proprietary Information is owned by EPRI and has been held in confidence by EPRI. All entities accepting copies of the Proprietary Information do so subject to written agreements imposing an obligation upon the recipient to maintain the confidentiality of the Proprietary Information. The Proprietary Information is disclosed only to parties who agree, in writing, to preserve the confidentiality thereof.

b.

EPRI considers the Proprietary Information contained therein to constitute trade secrets of EPRI. As such, EPRI holds the Information in confidence and disclosure thereof is strictly limited to individuals and entities who have agreed, in writing, to maintain the confidentiality of the Information.

c.

The information sought to be withheld is considered to be proprietary for the following reasons. EPRI made a substantial economic investment to develop the Proprietary Information and, by prohibiting public disclosure, EPRI derives an economic benefit in the form of licensing royalties and other additional fees from the confidential nature of the Proprietary Information. If the Proprietary Information were publicly available to consultants and/or other businesses providing services in the electric and/or nuclear power industry, they would be able to use the Proprietary Information for their own commercial benefit and profit and without expending the substantial economic resources required of EPRI to develop the Proprietary Information.

d.

EPRI's classification of the Proprietary Information as trade secrets is justified by the Uniform Trade Secrets Act which California adopted in 1984 and a version of which has been adopted by over

forty states. The California Uniform Trade Secrets Act, California Civil Code §§3426 - 3426.11, defines a "trade secret" as follows: "'Trade secret' means information, including a formula, pattern, compilation, program device, method, technique, or process, that: (1) Derives independent economic value, actual or potential, from not being generally known to the public or to other persons who can obtain economic value from its disclosure or use; and (2) Is the subject of efforts that are reasonable under the circumstances to maintain its secrecy."

e.

The Proprietary Information contained therein are not generally known or available to the public. EPRI developed the Information only after making a determination that the Proprietary Information was not available from public sources. EPRI made a substantial investment of both money and employee hours in the development of the Proprietary Information. EPRI was required to devote these resources and effort to derive the Proprietary Information. As a result of such effort and cost, both in terms of dollars spent and dedicated employee time, the Proprietary Information is highly valuable to EPRI.

f.

A public disclosure of the Proprietary Information would be highly likely to cause substantial harm to EPRI's competitive position and the ability of EPRI to license the Proprietary Information both domestically and internationally. The Proprietary Information can only be acquired and/or duplicated by others using an equivalent investment of time and effort. I have read the foregoing and the matters stated herein are true and correct to the best of my knowledge, information and belief. I make this affidavit under penalty of perjury under the laws of the United States of America and under the laws of the State of North Carolina. Executed at 1300 W WT Harris Blvd being the premises and place of business of Electric Power Research Institute, Inc. Date:. 3-** 1* -Z~o,,i, Neil Wilmshurst (State of North Carolina) (County of Mecklenburg) Subscribed__,and sworn to (o,. affirmed) before me on this ]_9:Jdy of "7"l; 20_1' by .il1ugf 4)}v,l'A..** . proved to me on the basis of satisf,,'*tory evidence to be the person(s) who appeared before me. 'I/ Signature QIt/*i /.i (Seal), MyCommission Expires ~ay of ,0..}}