ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 (REV_071 814)

Facility:

McGuire Date of Examination:

8/2014 Exam Level (circle one):

RO (only) / SRO(l) I SRO (U)

Operating Test No.:

N14-1 Control Room Systems@ (8 for RO; 7 for SRO-l; 2 or 3 for SRO-U, including 1 ESF)

Type Code*

Safety System / JPM Title Function A.

061 AuxiliarylEmergency Feedwater (AFW) System [061 A2.07 (3.4/3.5)]

S,M,A,EN 4S CA Suction Source Realignment B.

APE 032 Loss of Source Range NI [032 AA2.05 (2.9/3.2)]

S,D,L,A 7

Respond to a Source Range Nuclear Instrumentation Failure C.

006 Emergency Core Cooling System [006 A1.13 (3.513.7)]

S,M,EN 2

Increase Pressure in Cold Leg Accumulator IA D.

EPE E05 Loss of Secondary Heat Sink [E05 EA1.1 (4.1/4.0)]

S,M,A,EN 4P Establish NC System Feed and Bleed E.

APE 057 Loss of Vital AC Bus [057 AA2.18 (3.1/3.1)]

S,N,A 6

Restore Letdown during a Loss of EVDA/EKVA F.

APE 024 Emergency Boration [024 AA2.04 (3.4/4.2)]

S,M,A 1

Emergency Borate the NCS G.

E02 SI Termination [E02 EA1.1 (4.0/3.9)]

S,P,D,A,EN 3

Isolate the NV S/I Flowpath While Terminating Safety Injection H.

008 Component Cooling Water System [008 Al.01 (2.8/2.9)]

S,D 8

KC Pump Functional Verification In-Plant Systems@ (3 for RO; 3 for SRO-l; 3 or 2 for SRO-U)

I.

003 Reactor Coolant Pump System [003 A2.02 (3.7/3.9)]

D,R 4P Shift Seal Injection Filters J.

APE 065 Loss of Instrument Air [065 AAI.04 (3.513.4)]

D,E 8

Ensure Proper Response of Diesel VI Compressors on Loss of VI K.

001 Control Rod Drive System [001 A2.l0 (3.4/3.9)]

D,L 1

Start up the Unit 1A Motor Generator Set NUREG-1 021, Revision 9

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 (REV_071 814)

All RO and SRO-l control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

Type Codes Criteria for RO / SRO-l I SRO-U (A)lternate path 4-6 (6) /4-6 (6) / 2-3 (2)

(C)ontrol room (D)irect from bank 9 (6) / 8 (5) /

4 (3)

(E)mergency or abnormal in-plant 1 (1) / 1 (1) /

1 (1)

(EN)gineered Safety Feature

/

I 1 (2) (Control Room System)

(L)ow-Power / Shutdown 1 (2) / 1 (2) /

1 (1)

(N)ew or (M)odified from bank including 1(A) 2 (5) /

2 (5) /

1 (2)

(P)revious 2 exams 3(1) /

3(1)/

2 (0) (Randomly Selected)

(R)CA 1(1)/1(1)/1(1)

(S)imulator JPM Summary JPM A This is a modified Bank JPM. The operator will be told that Unit 1 has just tripped from 100%

power, due to seismic activity and that the crew is now implementing EP/1/A/5000/ES-0.1 (Reactor Trip Response).

The operator will be directed to monitor the ES-0.1 Foldout Page. The operator will be expected monitor the ES-0.1 Foldout Page, determine that Item #2 is applicable and use Generic Enclosure 20 (CA Suction Source Realignment) to realign the suction of the CA Pumps from the non-safety related to the safety-related source (RN).

During the course of this action, the operator will recognize that the RN Supply to the 1 B MDCA Pump cannot be established (Alternate Path), and stop the pump.

JPM B This is a Bank JPM. The operator will be told that Unit 1 is in the process of performing a Unit Start-Up, that Control Bank A has been pulled to 50 steps withdrawn, that Mode 2 has just been declared, that Source Range count rate is approximately 60 CPS, and that SR channel N-31 has failed low, but that SR channel N-32 is still OPERABLE. The operator will also be told that AP/1/A15500/16 Case I (Source Range Malfunctions) has been entered. The operator will be directed to remove the failed SR channel (N-31) from service by performing AP/1/A15500/16 (Malfunction of Nuclear Instrumentation), Case I

(Source Range Malfunctions). The operator will be expected to place the Source Range N31 Level Trip Bypass Switch to Bypass, and ensure that Source Range N32 is selected on the NIS Recorder. When the only other channel of SR Nuclear Instrumentation fails high and the reactor does not trip (Alternate Path), the operator will recognize that a reactor trip is required and then manually trip the Reactor.

JPM C This is a Modified Bank JPM. The operator will be told that the plant is at 100% power, and that the IA Cold Leg Accumulator Abnormal Press Alarm has been received.

The operator will be directed to respond to the alarm in accordance with the Annunciator Response Procedure. The operator will be expected to address the MCB Annunciator 1AD-9, E-1, select Enclosure 4.3 of OP/1!A/6200/009 to be performed, align N2 to the 1A CLA and raise pressure to greater than 610 psig and less than or equal to 639 psig.

NUREG-1 021, Revision 9

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 (REV 071814)

JPM D This is a modified Bank JPM. The operator will be told that a Reactor Trip on Lo-Lo S/G Level has occurred due to the loss of both Main Feedwater Pumps, that the CA System will not start, that EP/1IAI5000IFR-H.l (Loss of Secondary Heat Sink) has been implemented, and that Feed and Bleed initiation criteria has been met. The operator will be directed to initiate an NC System Feed and Bleed by performing Steps 22 through 28 of EP/1/A15000/FR-H.1 (Loss of Secondary Heat Sink). When the operator attempts to verify that a high pressure injection flowpath exists, it will be observed that the Safety Injection signal fails to manually actuate (Alternate Path).

The operator will be expected to manually start equipment as needed to establish an RCS feed and bleed flowpath such that all NCPs are off, High Pressure Injection flow is established through NI-9/10 and two Pzr PORVs are open.

JPM E This is a New JPM.

The operator will be told that with Unit 1 performing a reactor startup, the plant trips due to an electrical malfunction.

The crew is currently in EP/1IA/5000/ES-0.1 (Reactor Trip Response). The operator will be directed to perform AP/11A15500/15 (Loss of Vital or Aux Control Power), while the crew continues with this procedure.

The operator will be expected to use AP/11A15500/15 (Loss of Vital or Aux Control Power) to determine that normal letdown is not available (Alternate Path), and place excess letdown in service in accordance with EP/1/A/5000/G-1 (Generic Enclosures), Enclosure 2 (Establishing Excess Letdown).

JPM F This is a Modified Bank JPM.

The operator will be told that with the plant at power, a Reactor Makeup System failure has resulted automatic Control Rod insertion, that MCB Annunciator 1AD-2, A9, CONTROL ROD BANK LO

LIMIT, has
alarmed, that AP/1/A/5500/38 (Emergency Boration) has been entered, and that the 18 BA Transfer Pump is OOS.

The operator will be directed to initiate Emergency Boration by performing Step 12 of AP/11A15500138 (Emergency Boration).

After the operator starts the 1A BA Transfer Pump, Panel 1EXMA will de-energize, also de-energizing the 1A BA Transfer Pump (Alternate Path). The operator will be expected to establish Emergency Boration from the FWST.

JPM G This is a Bank JPM. The operator will be told that a plant transient at Unit 1 has resulted in a reactor trip from power and a Safety Injection actuation, that Safety Injection Termination criteria has been met and that the crew is implementing EP/1/A/5000/ES-1.1 (Safety Injection Termination).

The operator will be directed to isolate the NV S/I flowpath in accordance with Step 6

of EP/1/A/5000/ES-1.1 (Safety Injection Termination). While performing this task the operator will recognize that one NV Pump Recirculation Valve cannot be opened (Alternate Path). The operator will be expected to attempt to isolate NV S/I flow per EP/1/A1500/ES-1.1, recognize that this cannot be accomplished and complete Generic Enclosure 18 (Aligning Normal Charging With NV Recirc Path Isolated) to realign the NV system for normal charging, close the SI Injection valves and then maintain a minimum amount of charging flow to avoid overheating the NV Pumps.

JPM H This is a Bank JPM. The operator will be placed in a 100% power steady-state condition on Unit 1 with B Train components in service.

The operator will be told that it has become necessary to perform a Functional Verification of the A Train KC Pumps.

The operator will be directed to conduct a Functional Verification of the A Train KC Pumps in accordance with Enclosure 4.5 (KC Pump Functional Verification (Bump Start)) of OP/1/A6400/005 (Component Cooling Water System) using the 1A1 KC Pump.

The NUREG-1 021, Revision 9

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 (REV 071814) operator will be expected to start and stop the 1A1 K Pump, and adjust system flows both before and after pump operation.

JPM I

This is a Bank JPM.

The operator will be told that the plant is operating at power and MCB Annunciator 1AD-7, NC PUMP SEAL INJ LO FLOW, has just alarmed.

The operator will be directed to place lB seal injection filter in service by performing OPI1/A/62001001C (Chemical And Volume Control System Filters) Enclosure 4.2 (Shifting Seal Water Injection Filters and Assisting Maintenance in Change Out), Section 3.5.

The operator will be expected to place the lB seal injection filter in service per OP/11A16200/OO1C. This JPM may also be performed on Unit 2.

JPM J This is a Bank JPM. The operator will be placed in a situation with both Units at 100%

power when a leak develops in the VI system.

The operator will be told that API1/A15500/22, Loss of VI, has been implemented up to step 5.d, and that VI header pressure is 75 PSIG and going down. The operator will be directed to ensure that Diesel VI compressors are running per Enclosure 4 (Diesel VI Compressor Operation) of AP/1/A15500/22.

During the performance of this Enclosure, the G VI Diesel Air Compressor will fail to start the first time that a manual start is attempted. The operator will be expected to take action to in accordance with the Enclosure and re-start the G VI Diesel Air Compressor.

JPM K This is a Bank JPM. The operator will be told that a unit start-up is in progress on Unit 1 and that all requirements for entering Mode 2 are met. The operator will be directed to start the 1A M/G Set per OP/1/A16150/008 (Rod Control) Enclosure 4.1 (M/G Startup) for post maintenance inspection. The operator will be expected to start the 1A M/G Set per OP/1/A/61 50/008.

NUREG-1 021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIMJPMA 2014 Systems

- Control Room JPM A (Rev_071414)

NUREG 1021, Revision 9

Appendix C Page 2 of 11 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

CA Suction Source Realignment JPM No.:

2014 Systems

- Control Room JPM A (Alternate Path)

KJA

Reference:

061 A2.07 (3.4/3.5)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

Initial Conditions:

Unit 1 has just tripped from 100% power, due to seismic activity.

The crew is now implementing EP/1/A15000/ES-0.1 (Reactor Trip Response).

Initiating Cue:

The CRS has directed you to monitor the ES-0.1 Foldout Page and take required actions, if any.

Task Standard:

The operator will monitor the ES-0.1 Foldout Page, determine that Item

  1. 2 is applicable and use Generic Enclosure 20 (CA Suction Source Realignment) to realign the suction of the CA Pumps from the non safety related to the safety-related source (RN). During the course of this action, the operator will recognize that RN Supply to the 1 B MDCA Pump cannot be established, and stop the pump.

Required Materials:

None General

References:

EP/1/A15000/E-0 (Reactor Trip or Safety Injection), Rev 33 2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 3 of 1 1 Form ES-C-i Job Performance Measure Worksheet EPI1/AI5000IES-O.1 (Reactor Trip Response), Rev 37 EP/l IA/50001G-1 (Generic Enclosures), Rev 36 OMP 4-3 (Use of Abnormal and Emergency Procedures), Rev 37 Handouts:

Handout 1: EPI1IAI5000IES-O.1 Foldout Page.

Time Critical Task:

NO Validation Time:

15 minutes 2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 4 of 1 1 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset simulator to 10-39(100%).

2.

Place Simulator in RUN.

3.

Ensure that the B Train of RN is in operation.

4.

Insert REM-CA0O18B=0 to ensure that 1CA-188 (18 CA Pump Suction from lB RN Isol) will not OPEN.

5.

Insert (CA) PLP-078 = 1.48 (Simulates Leak in CAST).

6.

Override ON OBE Exceeded Annunciator (1AD-13 E-7). (1AD13_E07 = ON) 7.

Manually trip the reactor and perform the actions of EP/1/A15000/E-0, and transition to EP/1/A!5000/ES-01.

8.

Ensure both MDCA Pumps are running, acknowledge and silence all annunciators, and Freeze the Simulator.

OR 1.

Reset to lC-244 (April, 2014) 2.

Momentarily go to RUN to acknowledge Alarms then place Simulator in FREEZE.

3.

Leave Simulator in FREEZE until operator is ready to begin.

NOTE:

The BoothlFloor Instructor will need to control BOP during the performance of this JPM and ENSURE that SI Actuation is NOT needed.

2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 5 of 1 1 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (EPI1 /A15000/ES-0. 1 Foldout Page)

1. S/I Actuation Criteria:

IF NC subcooling based on core exit T/Cs is less than 0°F OR Pzr level cannot be maintained greater than 4%, THEN initiate S/I and GO TO EP/i/A/5000/E-0 (Reactor Trip Or Safety Injection).

IF S/I actuation occurs, THEN GO TO EP/i /A/50001E-0 (Reactor Trip Or Safety Injection).

2. CA Suction Sources:

IF CA Storage Tank (water tower) goes below 1.5 ft, THEN perform EPI1IAI5000IG-1 (Generic Enclosures), Enclosure 20 (CA Suction Source Realignment).

The operator observes NCS Subcooling Monitors and determines that subcooling is > 0°F.

The operator observes Pzr Level and determines that Pzr Level can be maintained > 4%.

The operator observes the SI Actuation Status Lights and determines that SI is NOT actuated.

The operator CAST Level, determines that level is <

1.5 feet, and addresses Generic Enclosure 20.

  • 1 Simulator Instructor NOTE: Leave Simulator in FREEZE until operator is ready to begin.

2014 Systems - Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 6 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 2

(Enclosure 20, Note prior to The operator reads the Step 1) If control room Note and proceeds.

indication of CA storage tank (water tower) has failed, local indication is available in turbine bldg, 760, 1 B-24.

(Step 1) Align A train RN to The operator observes the CA suction as follows:

iA RN Pump Red status light LIT, Green status light (Step 1.a) Start 1A RN OFF; and motor amps at pump.

88 amps, and determines the 1A RN Pump is running.

  • 4 (Step 1.b) OPEN 1 RN-69A The operator presses the (iA RN Assured Supply To 1 RN-69A OPEN pushbutton Ui CA Isol).

and observes the Red status light LIT, Green status light OFF.

The operator will acknowledge alarm on 1AD-5.

  • 5 (Step 1.c) OPEN 1 CA-i 5A The operator presses the (iA CA Pump Suction From ICA-15A OPEN pushbutton iA RN Isol) and observes the Red status light LIT, Green status light OFF.

The operator will acknowledge alarm on lAD-S.

  • 6 (Step 1.d) OPEN 1 CA-86A The operator presses the (Ui TD CA Pump Suction 1CA-86A OPEN pushbutton From 1A RN Isol).

and observes the Red status light LIT, Green status light OFF.

The operator will acknowledge alarm on i AD-5.

2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 7 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Step 2) Align B train RN to CA suction as follows:

(Step 2.a)OPEN1RN-162B The operator presses the (lB RN Assured Supply To 1RN-i62B OPEN Ui CA Isol).

pushbutton and observes the Red status light LIT, Green status light OFF.

The operator will acknowledge alarm on iAD-5.

8 (Step2.b)OPEN 1CA-i8B Theoperatorpressesthe (lB CA Pump Suction From 1CA-18B OPEN pushbutton 1 B RN Isol).

and observes the Green status light remains LIT, Red status light OFF (Alternate Path).

The operator proceeds to the RNO.

g (Step 2.b RNO) IF 18 CA The operator presses the pump is on, THEN stop lB RESET Pushbuttons and MD CA pump as follows:

observes RESET status lights LIT for both Train A (Step 2.b RNO 1) Reset S/I.

and B SI. (Already RESET) 10 (Step 2.b RNO 2) Reset 1 B The operator presses the Sequencer.

Sequencer RESET and observes RESET status lights LIT Pushbuttons for both Train A and B.

(Already RESET)

  • 1 1 (Step 2.b RNO 3) Stop 1 B The operator presses the CA pump.

STOP pushbutton for the 18 MDCA Pump and observes the Green status light LIT, Red status light OFF; and that motor amps drop to 0.

2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 8 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 12 (Step 2.b RNO 4) IF lB CA The operator observes that pump still on,....

the lB MDCA Pump is OFF, and proceeds.

13 (Step 2.c) OPEN 1 CA-i 1 6B The operator presses the (Ui TD CA Pump Suction 1CA-116B OPEN From 1 B RN Isol).

pushbutton and observes the Red status light LIT, Green status light OFF.

The operator will acknowledge alarm on 1 AD-5.

14 (Note prior to Step 3) The The operator reads the next step isolates non-NOTE and proceeds.

safety CA suction sources from 1A CA Pump.

  • 15 (Step 3) CLOSE 1 CA-i iA The operator presses the (iA CA Pump Suction Isol).

1CA-11A CLOSE pushbutton and observes the Green status light LIT, Red status light OFF.

16 (Step 4) Isolate non-safety CA suction sources from 1 B The operator presses the CA pump as follows:

1CA-9B CLOSE pushbutton and observes the Green (Step 4.a) CLOSE 1CA-9B status light LIT, Red status (1 B CA Pump Suction light OFF.

Isol).

17 (Step 4.b) IF 1CA-9B stays The operator recognizes in intermediate position for that 1 CA-9B is CLOSED more than 15 seconds, and proceeds.

THEN 2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 9 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS 18 ELEMENTS (Step 5) Isolate non-safety CA suction sources from TD CA pump as follows:

(Step 5.a) Check the following valves

- OPEN:

1RN-69A (1A RN Assured Supply To Ui CA Isol) 1CA-86A (Ui TD CA Pump Suction From 1A RN Isol).

STANDARD The operator observes the 1 RN-69A Red status light LIT, Green status light OFF.

The operator observes the 1CA-86A Red status light LIT, Green status light OFF.

S/U COMMENTS REQUIRED FOR UNSAT 19 (Step 5.b) GO TO Step 5.d.

The operator proceeds to Step 5.d.

  • 20 (Step 5.d) CLOSE 1 CA-The operator presses the 7AC (Ui TD CA Pump 1 CA-7AC CLOSE Suction Isol).

pushbutton and observes the Green status light LIT, Red status light OFF.

21 (Step 6) WHEN time allows, THEN....

Cue:

Another operator will complete the remaining steps.

Terminating Cue:

STOP TIME:

Evaluation on this JPM is complete.

2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Page 10 of 1 1 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM A Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM A NUREG 1021, Revision 9

Appendix C Form ES-C-I JPM CUE SHEET NlTIAL CONDITIONS:

Unit 1 has just tripped from 100% power, due to seismic activity.

The crew is now implementing EP/1/A/5000/ES-0.l (Reactor Trip Response).

INITIATING CUE:

The CRS has directed you to monitor the ES-0.1 Foldout Page and take required actions, if any.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM B 2014 Systems

- Control Room JPM B (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 13 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Respond to a Source Range JPM No.:

2014 Systems

- Control Nuclear Instrumentation Failure Room JPM B (Alternate Path)

K/A

Reference:

APE 032 AA2.05 (2.9/3.2)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

Initial Conditions:

Unit 1 is in the process of performing a Unit Start-Up.

Mode 2 has just been declared.

Control Bank A has been pulled to 50 steps withdrawn.

Source Range count rate is approximately 60 CPS.

SR channel N-31 has failed low.

SR channel N-32 is still OPERABLE.

AP/1/A/5500/16 Case I (Source Range Malfunctions) has been entered.

Initiating Cue:

The CRS has directed you to remove the failed SR channel (N-31) from service by performing AP/1/A/5500/16 (Malfunction of Nuclear Instrumentation), Case I (Source Range Malfunctions).

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 3 of 13 Form ES-C-i Job Performance Measure Worksheet Task Standard:

The operator will place the Source Range N31 Level Trip Bypass Switch to Bypass, and ensure that Source Range N32 is selected on the NIS Recorder. When the only other channel of SR Nuclear Instrumentation fails high and the reactor does not trip, the operator will recognize that a reactor trip is required and then manually trip the Reactor.

Required Materials:

None General

References:

AP111A15500116 (Malfunction of Nuclear Instrumentation), Rev 14 OPI1/AI6100IO1OA (Annunciator Response For Panel 1FO-1) Rev 14, ARP1 FO1/A-6, S/R HI Flux Rx Trip EPI1IA/N5000/E-O (Reactor Trip or Safety Injection), Rev 33 McGuire Technical Specifications, LCO 3.3.1 (RTS Instrumentation),

Amendment 184/i 66 Handouts:

Handout 1: AP/i/A15500/16 Malfunction of Nuclear Instrumentation, Case I

Time Critical Task:

NO Validation Time:

11 minutes 2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 4 of 13 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset Simulator to IC-26 (Mode 2, Normal operating temp/press, CBA at 50 steps withdrawn.)

2.

Insert Mal ENB-2A (SR Channel 31 Failure); Select = 0, Activate 3.

Insert Mal IPE001A (Failure of Auto Reactor Trip A train) 4.

Insert Mal IPEO01 B (Failure of Auto Reactor Trip B train) 5.

Insert Mal ENB-002B (SR Channel 32 Failure); Set = 1 e+006, Set to Trigger 1.

6.

Freeze Simulator.

7.

GotoRUN.

8.

Place Audio Count Rate and Startup Rate selectors to SR N-32 prior to implementing this JPM.

OR 1.

Reset Simulator to Temporary Snap IC-245 (April, 2014).

NOTE:

During the performance of the JPM, the Simulator Driver will be required to activate Trigger #1 when the operator places the operable Source Range Channel to record on the NIS Recorder in API6 Case I, step 14.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 5 of 13 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Caution prior to Step 1)

The operator reads Caution Pulling S/R control power and proceeds.

fuses anytime the S/R is energized will result in a reactor trip unless the affected channel is blocked in SSPS (SIR TRAIN (A/B)

TRIP BLKD HI VOLTAGE OFF status light on 1SI-18 is lit).

2 (Caution prior to Step 1)

The operator reads Caution Pulling S/R instrument and proceeds.

power fuses with the S/R energized will result in a reactor trip unless:

Affected channel LEVEL TRIP switch is in BYPASS OR Affected channel is blocked in SSPS (S/R TRAIN (A/B) TRIP BLKD HI VOLTAGE OFF status light on 1SI-i8 is lit).

3 (Note prior to Step 1) Audio The operator reads Note count rate is only supplied and proceeds.

from S/R channels N-31 or N-32.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 6 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 4

(Note prior to Step 1) In The operator reads Note Mode 6, the W/R Neutron and proceeds.

Flux Monitors can be used as S/R neutron flux indication.

5 (Step 1) Check at least one The operator recognizes that of the following S/R SR Channel N32 is Channels

- OPERABLE OPERABLE as identified in the initial conditions.

N-3i OR N-32 6

(Step 2) Announce The operator makes a page occurrence on paging announcement indicating system.

that SR Channel N31 has failed.

Cue If asked, the U2 RO makes the page announcement.

7 (Step 3) Check unit status The operator recognizes IN MODE 6.

from initial conditions that the plant is in Mode 2 and proceeds to the RNO.

8 (Step 3 RNO) GO TO Step The operator proceeds to 6.

Step 6.

9 (Step 6) Check S/R The operator determines detector(s)

- HIGH from initial conditions that VOLTAGE the plant is in Mode 2 and INADVERTENTLY proceeds to the RNO.

APPLIED AT POWER (ABOVE P-b).

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 7 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 10 (Step 6 RNO) GO TO Step The operator proceeds to 7.

Step 7.

1 1 (Step 7) Check SIR HI The operator observes MOB FLUX AT SHUTDOWN Annunciator 1AD2ID3 and alarm (1AD-2, D-3)

- DARK determines that the window is DARK.

12 (Step 8) Monitor available The operator observes hR Channels and W/R Neutron Flux is below the Neutron Flux Monitors IIR Channels scale.

The operator observes that WIR Monitor indications are stable.

13 (Step 9) Check if failure has The operator determines occurred on any of the from initial conditions that N-following S/R Channels:

31 has failed.

N-31 The operator observes SR OR Channel N31 indication at N-32 0.

14 (Step 10) Check at least The operator recognizes that one of the following S/R SR Channel N32 is channels OPERABLE OPERABLE as identified in the initial conditions.

N-3i OR The operator observes SR N-32 Channel N32 is reading 60 CPS.

15 (Step 1 1) Check unit status The operator determines

- IN MODE 3, 4, 5, 6 OR from initial conditions that NO MODE the plant is in Mode 2 and proceeds to the RNO.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 8 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT i6 (Step ii RNO) IF in Mode 2 The operator determines below P-6, THEN suspend unit is in Mode 2 and below operations involving positive P-6 (10 -10 lR amps), and reactivity additions.

observes rod withdrawal has stopped.

Startup has been pended 17 (Step 12) Perform the following actions on the failed S/R drawer:

(Step 12.a) Place the The operator places the N3i LEVEL TRIP switch to Level Trip switch to BYPASS BYPASS and observes Level Trip light is LIT.

(Step 12.b) Check LEVEL TRIP BYPASS light

- LIT (Step 12.c) Place the HIGH The operator recognizes that FLUX AT SHUTDOWN the High Flux at Shutdown switch to BLOCK.

Switch is in the BLOCK position.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 9 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 18 (Step 13) Check the following S/R indications:

(Step 13.a) Check SIR The operator observes MCB OR hR TRIP BYPASS Annunciator 1AD2/E2 and alarm (1AD-2, E-2) determines that the window LIT.

is LIT.

(Step 13.b) Check the failed channels status light on 1SI-i9:

The operator observes the iIN-31B S/R N31 Trip Bypass status light CHANNEL I is LIT.

TRIP BYPASS

- LIT OR 1IN-32B S/R CHANNEL II TRIP BYPASS LIT.

(Step i3.c) Check unit The operator proceeds to status

- IN MODE,

the Ste 13 c RNO 5, 6, OR NO MODE.

19 (step 13.c RNO) Perform The operator recognizes that the following:

the plant is in Mode 2 below P-6, and proceeds to Step (step i3.c RNO 1) IF unit 13.d.

status in Mode 2 below P-6, THEN GO TO Step 1 3.d.

20 (Step i3.d) Check SIR HI The operator observes MCB FLUX ALM BLOCKED Annunciator 1AD2/D2 and alarm (1AD-2, D-2)

- LIT.

determines that the window is LIT.

  • 21 (Step 14) Place operable The operator places the NIS S/R channel to record on Recorder Switch to the S2 NIS Recorder.

position.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 10 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT NOTE:

Simulator Driver Operate Trigger #1.

This will cause the SIR HI FLUX RX TRIP alarm on IFO-1!A5 (An automatic Reactor Trip should occur, however, the RPS has failed. The Operator may address the Annunciator Response Procedure, however, it is expected that the reactor will be manually tripped)

Examiner NOTE: (Alternate Path) It is expected that the operator will Trip the Reactor.

  • 22 (Step 2) Check Reactor The operator manually trips Trip the reactor.

All rod bottom lights

LIT NOTE: The remainder of the operator actions will be Reactor trip and bypass performed from memory breakers OPEN The operator observes all Rod Bottom lights are LIT I/R amps GOING (green).

DOWN The operator observes Reactor Trip Breaker green status lights are LIT.

The operator observes that both hR SUR indications are trending down 23 (Step 3) Check Turbine Trip All throttle valves The operator observes the CLOSED Four STAT lights for throttle valves are LIT.

24 (Step 4) Check 1 ETA and The operator observes that 1 ETB

- ENERGIZED UV STAT lights for 1 ETA and 1 ETB are DARK.

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 1 1 of 13 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 25 (Step 5) Check if S/I is actuated:

(Step 5.a) SAFETY INJECTION ACTUATED The operator observes that status light (1sI-18)

- LIT.

S/I actuate light is DARK.

26 (Step 5.a RNO) Perform the following:

(Step 5.a RNO 1)

Check if S/I is required:

Operator observes that Pzr pressure is greater than Pzr pressure less than 2200 and stable and that 1845 Containment pressure is.15 OR PSIG and stable; and Containment pressure reports that Safety Injection greater than 1 PSIG is NOT required.

Cue:

The CRS acknowledges the report.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Page 12 of 13 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM B Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM B NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

Unit 1 is in the process of performing a Unit Start-Up.

Mode 2 has just been declared.

Control Bank A has been pulled to 50 steps withdrawn.

Source Range count rate is approximately 60 CPS.

SR channel N-31 has failed low.

SR channel N-32 is still OPERABLE.

API1/A/5500116 Case I (Source Range Malfunctions) has been entered.

INITIATING CUE:

The CRS has directed you to remove the failed SR channel (N-3i) from service by performing AP/i/A15500/16 (Malfunction of Nuclear Instrumentation), Case I (Source Range Malfunctions).

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM C 2014 Systems

- Control Room JPM C (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 15 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Increase Pressure in Cold Leg JPM No.:

2014 Systems

- Control Accumulator 1A Room JPM C K/A

Reference:

006 A1.13 (3.5/3.7)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

Initial Conditions:

The plant is at power.

MCB Annunciatoi i,-J-9, E-1, A COLD LEG ACCUMULATOR ABNORMAL PRESS, has just alarmed.

Initiainn e Rntrr1 f,, i1(P nriinritnr I flQ I CflI fl I

Task Standard:

The operator will address the MCB Annunciator 1 AD-9, E-1, select.3 of OP/i!A!6200/009 to be performed, align N2 to the 1A CLA and raise pressure to greater than 610 psig and less than or equal to 639 psig.

Required Materials:

None General

References:

OP/i/A16100/0i0 J (Annunciator Response For Panel 1AD-9), Rev 56 OP/i !A/6200!009 (Accumulator Operation), Rev 106 2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 3 of 15 Form ES-C-i Job Performance Measure Worksheet SOMP 01-07 (Control Room Oversight), Rev 1 AD-OP-ALL-i 000 (Conduct of Operations), Rev 1 McGuire Technical Specification LCO 3.5.1 (Accumulators), Amendment 218 Handouts:

None Time Critical Task:

NO Validation Time:

25 minutes 2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 4 of 15 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset the Simulator to IC-39 100% Power, MOL 2.

Open 1 N 1-50 and throttle open the manual loader for 1 Nl-83 to bring CLA A down to the low pressure alarm setpoint (approximately 590 psig) 3.

Close lNl-50 and lNl-83 4.

Freeze the Simulator OR 1.

Reset Simulator to Temporary Snap lC-250 (April, 2014) 2.

Momentarily place Simulator in Run to acknowledge alarms.

3.

Leave Simulator in FREEZE until operator is ready to begin.

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 5 of 15 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 1

(ARP

- Immediate Actions)

The operator observes the Monitor for accumulator 1A CLA pressure on OAC pressure and level changes.

M1A0634, or 1NIP-5040/5050, to be 580 psig.

The operator observes the iA CLA level on the OAC or 1 NIL-504015050, to be normal.

2 (ARP Supplementary The operator informs the Actions 1) Investigate all CRS that the crew must leakage paths.

investigate all leak paths.

As the CRS, indicate that the Work Control Center will be directed to perform this action 2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 6 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 3

(ARP Supplementary The operator informs the Actions 2) Refer to Tech CRS that the Technical Specs.

Specifications must be evaluated.

AS tne CRS, indicate that they will evaluate the Technical Specifications.

NOTE: If the operator addresses Technical Specifications, As the CRS, indicate that they will evaluate the Technical Specifications, and direct them to continue.

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 7 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 4

  • 4 (ARP Supplementary The operator informs the Actions 3) Refer to CRS that the crew must OPI1/A162001009 refer to 0P111A16200/009.

(Accumulator Operation) for adjusting accumulator pressure.

is tneiw. astc me

]HI1I(][ W11lL iIZIIGfl wifhiri fhi rrarv1.ir i recommended.

The operator informs the CRS that the crew must perform Enclosure 4.3 (Adjusting Accumulator Pressure) of 0P111A162001009.

Cue:

If asked, as the CRS state that the IA CLA pressure should be raised to 615+/-

psig.

Examiner Note:

If another Enclosure within OPIIIA!62001009 is selected, the JPM will be failed when the operator first manipulates the MCB in an Enclosure other than 4.3 (i.e. if the operator corrects the incorrect selection of Enclosures prior to manipulation of the MCB, the JPM is NOT necessarily failed).

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 8 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 5

(ARP Supplementary The operator observes the Actions 4) Check DCS DCS Workstation alarms Workstation alarms.

and report any recent alarm activity.

6 (Step 2i) GN System The operator calls the Work aligned per Control Center and asks if OP/O/B16450/008 (Nitrogen the GN System aligned per System).

OP/O/B/64501008.

Cue:

As the WCC Supervisor, state that the GN System is aligned per the procedure.

7 (Step 2.2) CLA Level within The operator informs the proper Tech Spec range.

CRS that the 1 CLA level must be within the Technical Specification Limit.

Cue:

As the CRS, state that the IA CLA must be between 6870 and 7342 gallons.

The operator observes the 1A CLA level on the OAC or 1 NIL-504015050, to be within this range.

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 9 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 8

(Step 3.1) Evaluate all The operator calls the Work outstanding R&Rs that may Control Center and asks if impact the performance of the all outstanding R&Rs this procedure.

have been evaluated for the 1A CLA.

Cue:

As the WCC Supervisor, state that there are no outstanding R&Rs associated with the IA CLA.

  • 9 (Step 3.2) Perform the The operator proceeds to Section 3.3.

following sections as applicable:

Examiner Note:

Section 3.3, Increasing If another Section within Accumulator Pressure.3 is selected, the JPM will be failed Section 3.4, Decreasing when the operator first Accumulator Pressure manipulates the MCB in a Section other than 3.3 (i.e.

Section 3.5, Adjusting if the operator corrects Accumulator Pressure via the incorrect selection of Equalization the appropriate Section prior to manipulation of the MCB, the JPM is NOT necessarily failed).

10 (NOTE prior to Step 3.3) IF The operator reads the CLAs have been completely NOTE, recognizes that it depressurized, CLA does NOT apply, and Nitrogen Heater is required.

proceeds.

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 10 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQU IRED FOR UNSAT 1 1 (Step 3.3) Increasing CLA pressure (Step 3.3.1) Ensure 1NI-83 The operator observes the (CL Accum N2 Hdr Atmos 1 Nl-83 controller output at Vent Isol) closed.

0%.

12 (Step 3.3.2) IF required, The operator recognizes start Unit 1 & 2 NI that the heaters are NOT Accumulator N2 HTR...

required (Per the Note prior to Step 3.3), and proceeds.

Cue:

If the operator addresses the issue to the CRS, as the CRS, state that the heater is NOT required.

  • 13 (Step 3.3.3) Open 1 NI-47A The operator presses the (Rx Bldg N2 Supply Isol) 1NI-47A OPEN pushbutton and observes the Red status light LIT, Green status light OFF.

The operator acknowledges Annunciator B-3 on the ESF Monitor Light Panel as an expected alarm.

14 (NOTEs prior to Step 3.3.4)

The operator reads the To maintain Tech Spec NOTEs and proceeds.

operability, only one CLA at a time can have associated liquid fill valve, gas fill valve, or sample valve open.

If LTOP in service, only A or B CLA can have associated liquid fill valve, gas fill valve, or sample valve open at a time.

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

(Step 3.3.4) IF increasing pressure in A CLA, perform the following:

(Step 3.3.4.1) Adjust 650 psig Nitrogen regulator at Bulk Nitrogen House to a Pressure adequate for makeup to A CLA:

1GN-38 (650 psig Nitrogen Hdr Press Reg)

OR 1GN-41 (650 psig Nitrogen Hdr Press Backup Reg)

(Step 3.3.4.2) Open 1 N 1-50 (A CL Accum N2 Supply Isol).

The operator contacts an AO, and directs that Nitrogen pressure be adjusted to 650 psig.

Cue:

The AO reports that IGN 38 has been adjusted so that Nitrogen pressure is 650 psig.

The operator presses the lNl-50 OPEN pushbutton and observes the Red status light LIT, Green status light OFF.

Appendix C Page 11 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 15 2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

(Step 3.3.4.3) After CLA at desired pressure, back out 650 psig Nitrogen Regulator at Bulk Nitrogen House.

3.3.4.4) Close lNl-50 (A CL Accum N2 Supply Isol).

The operator observes the 1A CLA pressure on OAC M1A0634, or 1NIP-5040/5050, to be >610 psig but 639 psig.

TechSpecHi Alarm Hi Alarm Lo Tech Spec LO The operator contacts the AC, and directs that 1GN-38 be backed out.

Cue:

Simulator Instructor:

REM-GNOO4O = 0 REM-GN0037 = 0 The AO reports that IGN 38 has been backed out.

The operator presses the 1NI-50 CLOSE pushbutton and observes the Green status light LIT, Red status light OFF.

(Step 3.3.5) If increasing pressure in B CLA The operator recognizes that the B CLA pressure is NOT being raised, and proceeds.

(Step 3.3.6) If increasing pressure in C CLA The operator recognizes that the C CLA pressure is NOT being raised, and proceeds.

STEPS Appendix C Page 12 of 15 Form ES-C-i PERFORMANCE INFORMATION ELEMENTS STANDARD 17 S/U COMMENTS REQUIRED FOR UNSAT 1GN-38 (650 psig Nitrogen Hdr Press Reg)

OR 639 psig 633 psig 590 psig

>585 Dsia 1GN-41 (650 psig Nitrogen Hdr Press Backup Reg) 2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 13 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 21 (Step 3.3.7) If increasing The operator recognizes pressure in D CLA,.....

that the D CLA pressure is NOT being raised, and proceeds.

22 (Step 3.3.8) Close 1 NI-47A The operator presses the (Rx Bldg N2 Supply Isol) 1 NI-47A CLOSE pushbutton and observes the Green status light LIT, Red status light OFF.

The operator observes that Annunciator B-3 on the ESF Monitor Light Panel is DARK.

23 (Step 3.3.9) If required, turn The operator recognizes off Unit 1 & 2 NI Accum N2 that the step does NOT HTR apply, and proceeds.

Anathr nnriftr will continue witntnis tasx.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Page 14 of 15 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM C Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM C NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

The plant is at 1 00% power.

MCB Annunciator 1AD-9, E-1, A COLD LEG ACCUMULATOR ABNORMAL PRESS, has just alarmed.

INITIATING CUE:

Respond to MCB Annunciator 1AD-9, E-1, A COLD LEG ACCUMULATOR ABNORMAL PRESS, in accordance with the Annunciator Response Procedure.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM 0 2014 Systems

- Control Room JPM D (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 14 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Establish NC System Feed and JPM No.:

2014 Systems

- Control Bleed Room JPM D (Alternate Path)

K/A

Reference:

EPE E05 EA1.1 (4.1/4.0)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

Initial Conditions:

A Reactor Trip on Lo-Lo SIG Level has occurred due to the loss of both Main Feedwater Pumps.

The CA System will not start.

EP/1/A15000/FR-H.1 (Loss of Secondary Heat Sink) has been implemented.

Feed and Bleed initiation criteria has been met.

Initiating Cue:

The CRS has directed you to initiate an NC System Feed and Bleed by performing Steps 22 through 28 of EP/1/A15000/FR-H.i (Loss of Secondary Heat Sink).

Task Standard:

The operator establishes an RCS feed and bleed flowpath such that all NCPs off, High Pressure Injection flow is established through NI-9/10 and two Pzr PORVs are open.

Required Materials:

None 2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 3 of 14 Form ES-C-i Job Performance Measure Worksheet General

References:

EP/1/A/5000/FR-H.1 (Loss of Secondary Heat Sink), Rev. 17 AD-OP-ALL-i 000 (Conduct of Operations), Rev 1 Handouts:

Handout 1: EP/1/A!5000/FR-H.1 (Loss of Secondary Heat Sink) marked up for place-keeping through Step 5.

Time Critical Task:

NO Validation Time:

5 minutes 2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 4 of 14 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset to IC-39, 100%, MOL.

2.

Insert the following malfunctions:

IPEOO1A, Reactor fails to trip in AUTO, Train A IPEOO1B, Reactor fails to trip in AUTO, Train B DEHOO3A, Turbine fails to trip in AUTO CAOO4A, MDCA Pump A fails to start CAOO4B, MDCA Pump B fails to start CAOO5, TDCA Pump fails to start ISEOO2A, Failure of SI to Actuate in AUTO and MANUAL, Train A ISEOO2B, Failure of SI to Actuate in AUTO and MANUAL, Train B 3.

Place Simulator in Run and acknowledge Annunciator Alarms.

4.

Manually Trip both Feed Pumps.

5.

Allow at least 3 S/Gs to decrease below 24% WR level.

6.

Manually trip the reactor and turbine 7.

Ensure that EP/1/A/5000/FR-H.1 is completed through Step 5. (E-0 to FR-S.1 to FR H.1) 8.

Freeze the Simulator.

OR 1.

Reset Simulator to Temporary Snap IC-247 (April, 2014) 2.

Momentarily place Simulator in Run to acknowledge alarms.

3.

Leave Simulator in FREEZE until operator is ready to begin.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 5 of 14 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT Simulator Instructor NOTE: Leave Simulator in FREEZE until operator is ready to begin.

(Step 22) Perform Steps 23 The operator reads the step through 27 quickly to and proceeds.

establish NC heat removal by NC feed and bleed.

  • 2 (Step 23) Ensure all NC The operator presses the Pumps OFF.

STOP pushbutton for the iA NCP Pump and observes the Green status light is LIT, and Red status light is OFF.

The operator presses the STOP pushbutton for the 1 B NCP Pump and observes the Green status light is LIT, and Red status light is OFF.

The operator presses the STOP pushbutton for the 1C NCP Pump and observes the Green status light is LIT, and Red status light is OFF.

The operator presses the STOP pushbutton for the 1D NCP Pump and observes the Green status light is LIT, and Red status light is OFF.

2014 Systems - Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 6 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 3 (Step 24) Initiate S/I.

The operator presses the S/I INITIATE pushbuttons for Train A and Train B, and observes that the SI Actuation status light remains DARK.

4 (Step 25) Check NV PMPS The operator observes NI-TO COLD LEG FLOW

1 NVP-6080 at 0 gpm, and INDICATING FLOW.

determines that there is NO flow from the NV Pumps, and proceeds to the Step 25 RNO. (Alternate Path) 5 (Step 25 RNO) Perform the The operator observes the following:

iA NV Pump Green status light is LIT, and determines (Step 25 RNO a) Start NV that the pump is OFF.

Pumps.

The operator presses the iA NV Pump START pushbutton and observes the Red status light is LIT, Green status light is OFF, and amperage indicated, and determines that the 1A NV Pump is running.

The operator observes the 1 B NV Pump Red status light is LIT, Green status light is OFF, and amperage indicated, and determines that the 1 B NV Pump is running.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 7 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 6 (Step 25 RNO b) Start NI The operator observes the Pumps.

iA NI Pump Green status light is LIT, and determines that the pump is OFF.

The operator presses the 1A NI Pump START pushbutton and observes the Red status light is LIT, Green status light is OFF, and amperage indicated, and determines that the iA NI Pump is running.

The operator observes the lB NI Pump Green status light is LIT, and determines that the pump is OFF.

The operator presses the lB NI Pump START pushbutton and observes the Red status light is LIT, Green status light is OFF, and amperage indicated, and determines that the 1 B NI Pump is running.

NOTE:

Starting one of these pumps satisfies the critical nature of this Step.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 8 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 7 (Step 25 RNO c) OPEN the The operator observes the following valves:

INV-221A Green status light is LIT, and determines 1NV-221A (Ui NV that the valve is CLOSED.

Pump Suct From FWST Isol)

The operator presses the 1 NV-221A OPEN pushbutton and observes 1 NV222B (Ui NV Pump the Red status light is LIT, Suct From FWST Isol)

Green status light is OFF, and determines that 1 NV 221A is OPEN.

The operator observes the 1 NV-222B Green status light is LIT, and determines that the valve is CLOSED.

The operator presses the 1 NV-222B OPEN pushbutton and observes the Red status light is LIT, Green status light is OFF, and determines that 1 NV 222B is OPEN.

NOTE:

Opening one of these valves satisfies the critical nature of this Step.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 9 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 8 (Step 25 RNO d) CLOSE The operator observes the the following valves:

1NV-141A Red status light is LIT, and determines that 1NV-i4lA (Ui VCT the valve is OPEN.

Outlet Isol).

The operator presses the 1NV-i4iA CLOSE 1NV-i42B(U1 VCT pushbutton and observes Outlet Isol).

the Green status light is LIT, Red status light is OFF, and determines that 1NV-l4iA is CLOSED.

The operator observes the 1NV-142B Red status light is LIT, and determines that the valve is OPEN.

The operator presses the 1NV-i42B CLOSE pushbutton and observes the 1NV-i42B Green status light is LIT, Red status light is OFF, and determines that 1NV-142B is CLOSED.

NOTE:

Opening one of these valves satisfies the critical nature of this Step.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

(Step 25 RNO e) OPEN the following valves:

1NI-9A(NC Cold Leg The operator observes the lNl-9A Green status light is LIT, and determines that 1NV-9A is CLOSED.

The operator presses the 1NI-9A OPEN pushbutton and observes the Red status light is LIT, Green status light is OFF.

The operator observes the 1NI-1OB Green status light is LIT, and determines that 1NV-10B is CLOSED.

The operator presses the 1NI-1OB OPEN pushbutton and observes the Red status light is LIT, Green status light is OFF.

(Step 25 RNO f) IF NV S/I flowpath is established, AND NV Pump is on THEN GO TO Step 26.

The operator observes 1 NVP-6080 at 300 gpm, and determines that there is flow from the NV Pumps, and proceeds to Step 26.

Appendix C Page 10 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 9 I nj.).

iNl-1OB (NC Cold Leg I nj.).

NOTE:

Opening one of these valves satisfies the critical nature of this Step.

10 2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 1 1 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 1 1 (Step 26) Establish NC System bleed path as follows:

(Step 26.a) Check all Pzr The operator observes the PORV isolation valves

1 NC-31 B Red status light is OPEN.

LIT, and determines that 1NC-31B is OPEN.

The operator observes the 1NC-33A Red status light is LIT, and determines that 1NC-33A is OPEN.

The operator observes the 1 NC-35B Red status light is LIT, and determines that 1 NC-35B is OPEN.

  • 12 (Step 26.b) Select OPEN The operator rotates the on two Pzr PORVs that 1 NC-32B, 34A or 36B have an open Pzr PORV control switch clockwise, isolation valve, and observes the Red status light LIT.

The operator rotates the 1NC-32B, 34Aor36B control switch clockwise, and observes the Red status light LIT.

13 (Step 26.c) Align N2 to Pzr PORVs by OPENING the following valves:

The operator presses the 1 NI-430A (Emerg N2 1 NI-430A OPEN From CLA To 1 NC-pushbutton and observes 34A).

the Red status light is LIT, Green status light is OFF.

1 NI-431 B (Emerg N2 The operator presses the From CLAT0 1NC-32B lNl-431B OPEN

& 36B).

pushbutton and observes the Red status light is LIT, Green status light is OFF.

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 12 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 14 (Step 26.d) Check power to The operator observes the all Pzr PORV isolation RED status light LIT for all valves AVAILABLE, three PORV Isolation Valves, and determines that power is available to each.

15 (Step 27) Check two Pzr The operator observes the PORVs and associated 1 NC-32B, 34A or 36B RED isolation valves OPEN.

status light LIT for two of the three PORVs, and determines that two valves are OPEN.

  • 16 (Step 28) Isolate NV Recirc flowpath as follows:

(Step 28.a) CLOSE the following valves:

The operator presses the 1NV-i5OB (Ui NV 1NV-i SOB CLOSE Pump Recirc Isol).

pushbutton and observes the Green status light is LIT, Red status light is OFF.

1NV-151A (Ui NV The operator presses the Pump Recirc Isol).

1NV-l5iA CLOSE pushbutton and observes the Green status light is LIT, Red status light is OFF.

17 (Step 28.b) Maintain NV The operator reports to the recirc valves closed unless CRS that Steps 22-28 of directed to open by EPI1IAI500IFR-H.1 have subsequent steps.

been performed.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Page 13 of 14 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM D Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM D NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

A Reactor Trip on Lo-Lo SIG Level has occurred due to the loss of both Main Feedwater Pumps.

The CA System will not start.

EP/1/A15000/FR-H.1 (Loss of Secondary Heat Sink) has been implemented.

Feed and Bleed initiation criteria has been met.

INITIATING CUE:

The CRS has directed you to initiate an NC System Feed and Bleed by performing Steps 22 through 28 of EPI1IAJ5000IFR-H.i (Loss of Secondary Heat Sink).

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM E 20i4 Systems

- Control Room JPM E (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 14 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Restore Letdown during a Loss of JPM No.:

2014 Systems

- Control EVDAIEKVA Room JPM E (Alternate Path)

K/A

Reference:

APE 057 AA2.i8 (3.1/3.1)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

Initial Conditions With Unit 1 performing a reactor startup, the plant trips due to an electrical malfunction.

The crew is currently in EP/i/A15000/ES-0.i (Reactor Trip Response).

Initiating Cue:

The CRS has directed you to perform AP/1/A15500/15 (Loss of Vital or Aux Control Power), while the crew continues with ES-0.i.

Task Standard:

The operator will use AP/i/A15500/15 (Loss of Vital orAux Control Power) to determine that normal letdown is not available, and place excess letdown in service in accordance with EP/1/A15000/G-i (Generic Enclosures), Enclosure 2 (Establishing Excess Letdown).

Required Materials:

None General

References:

AP/1/A/5500/15 (Loss of Vital orAux Control Power), Rev 26 EP/1/A15000/G-1 (Generic Enclosures), Rev 36 2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 3 of 14 Form ES-C-i Job Performance Measure Worksheet EPI1IAI5000IES-O.i (Reactor Trip Response), Rev 36 OMP 4-3 (Use of Abnormal and Emergency Procedures), Rev 37 SOMP 01-07 (Control Room Oversight), Rev 1 Handouts:

None Time Critical Task:

NO Validation Time:

15 minutes 2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 4 of 14 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset simulator to 10-12 (Reactor Startup in progress Reactor Subcritical).

2.

Place in RUN 3.

Insert MAL-EPLO02A (Loss of EVDAILoss of EVKA).

4.

Manually trip the Reactor.

5.

Acknowledge alarms.

6.

Freeze the Simulator.

OR 1.

Reset to 10-248 (April, 2014) 2.

Momentarily go to RUN to acknowledge Alarms then place Simulator in FREEZE.

3.

Leave Simulator in FREEZE until operator is ready to begin.

NOTE:

The Simulator Instructor will need to silence non-pertinent alarms as the JPM is performed.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 5 of 14 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT Simulator Instructor NOTE: Leave Simulator in FREEZE until operator is ready to begin.

(Step 1) Check ND

- IN The operator observes a RHR MODE.

plant startup was in progress and recognizes that RHR is NOT in service.

2 (Step 1 RNO) GO TO Step The operator proceeds to 4.

Step 4.

(Step 4) Check letdown

- IN The operator observes SERVICE.

Letdown flow to be 0, and determines that Letdown is not in service.

(Step 4 RNO) Reduce The operator adjusts 1 NV-charging to minimum while 238 and 1 NV-241 as maintaining the following:

needed to establish at least 6 GPM to each NC pump

. At least 6 GPM to each seal, and to maintain Pzr NC pump seal level at program.

. Pzr level at programmed level.

(Step 5) Check position of The operator observes that all MSIVs (using control the MSIV Green status board indications or status lights are LIT.

lights)

- OPEN.

6 (Step 5 RNO) IF any MSIV The operator observes that is CLOSED THEN perform the Reactor Trip Breaker the following:

Green status lights are LIT, and proceeds to Step 6.

IF reactor is tripped, THEN GO TO Step 6.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

(Step 6 RNO) Perform the following:

(Step 6 RNO a) IF letdown isolated, THEN have available operator restore letdown PER one of the following while continuing with this procedure:

IF letdown orifice valves have power, THEN establish normal letdown PER EPI1/A15000/G-l (Generic Enclosures), (Establishing Normal Letdown).

OR IF unable to restore normal letdown, THEN establish excess letdown PER EP/1IAI5000IG-1 (Generic Enclosures), Enclosure 2 (Establishing Excess Letdown)

(Generic Enclosure 2, Step

1) Check KC System alignment:

(Step 1.a) Containment pressure HAS REMAINED BELOW 3 PSIG.

The operator observes the 1 NV-457A and 1 NV-458A Green and Red status lights are OFF, and determines that Excess Letdown must be placed in service (Alternate Path).

The operator proceeds to EPI1/A/50001G-1, (Establishing Excess Letdown).

The operator observes Containment Pressure on OAC (or equivalent), and determines that Containment Pressure has remained less than 3 psig.

Appendix C Page 6 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQU IRED FOR UNSAT (Step 6) Check Vital AC The operator observes the panelboard 1 EKVA top row of channel status energized as follows:

lights and recognizes that they are LIT, and proceeds Top row of channel status to the Step 6 RNO.

lights NORMAL.

  • 8 If the operator informs the CRS of the selected path chosen to restore Letdown, as the CRS, acknowledge the choice.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 7 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 10 (Step 1.b) All KC pumps -

The operator observes the ON.

both 1B1 and 182 KC Pump Green status lights are LIT, Red status lights are OFF, and recognizes that only the A Train KC Pumps are ON.

(Step 1.b RNO 1) IF either train KC pumps off, THEN perform the following:

CLOSE from control room or dispatch operator to CLOSE the following valves on idle train:

A Train:

1 KC-230A (Tm A Rx Bldg Non Ess Sup Isol) (aux bldg, 750+12, JJ-55, above north end of KC HX 1A).

1 KC-3A (Tm A Rx Bldg Non Ess Ret Isol) (aux bldg, 733+8, HH-55, north of column HH-55).

OR B Train:

The operator observes that the B Train is the Idle Train.

1 KC-228B (Tm B Rx Bldg Non Ess Sup Isol) (aux The operator observes the bldg, 750+18, JJ-55, above IKC-228B Green status middle of KC HX 1 B).

light is LIT, Red status light is OFF.

1KC-18B (Tm B Rx Bldg Non Ess Ret Isol) (aux bldg, 739+9, HH-56, north of KC The operator observes the 1KC-18B Green status light Pump 181).

is LIT, Red status light is OFF.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 8 of 14 Form ES-C-I PERFORMANCE INFORMATION STEPS 12 ELEMENTS (Step 1.b RNO 2) WHEN idle train isolated from Reactor Bldg header per step above, THEN OPEN the following valves on operating train:

A Train:

1 KC-3A (Tm A Rx Bldg Non Ess Ret Isol).

1 KC-230A (Tm A Rx Bldg Non Ess Sup lsol).

OR B Train:

1KC-18B (Tm B Rx Bldg Non Ess Ret lsol).

1KC-228B (Tm B Rx Bldg Non Ess Sup Isol).

STANDARD The operator observes the 1 KC-3A Red status light is LIT, Green status light is OFF.

The operator observes the 1 KC-230A Red status light is LIT, Green status light is OFF.

S/U COMMENTS REQUIRED FOR UNSAT 13 (Step 1.b RNO 3) Do not The operator reads the step continue until KC aligned to and continues.

Reactor Bldg header.

  • 14 (Step 1.c) OPEN 1 KC-305B The operator presses the (Ui KC To Excess L/D Hx OPEN pushbutton for 1 KC Cont Outside Isol).

305B, and observes the Red status light is LIT, Green status light is OFF.

15 (Step I.d) Check KC Surge The operator observes Tank levels

- STABLE.

1 KCP 5630 and 5640 and determines that the KC Surge Tank levels are stable, and proceeds.

  • 16 (Step l.e) OPEN 1KC-315B The operator presses the (Ui Excess L/D Hx KC Ret OPEN pushbutton for 1KC-Hdr Cont Otsd Isol).

315B, and observes the Red status light is LIT, Green status light is OFF.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 9 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 17 (Step 1.f) Check The operator observes containment pressure

Containment Pressure on HAS REMAINED BELOW 3 OAC (or equivalent), and PSIG.

determines that Containment Pressure has remained less than 3 psig.

18 (Step 2) Pressurize excess letdown line as follows:

The operator observes the (Step 2.a) Place 1 NV-27B 1 NV-27B White VCT status (Ui Excess L/D Hx Outlet light is LIT.

3-Way Cntrl) to VCT position.

19 (Note prior to Step 2.b)

The operator reads the Opening and then closing Note and proceeds.

1NV-26B (Ui Excess LID Hx Outlet Cntrl) in the next steps will reduce the possibility of water hammer by ensuring that the excess letdown line is filled with water.

20 (Step 2.b) OPEN 1 NV-26B The operator rotates the (Ui Excess L/D Hx Outlet adjust knob clockwise on Cntrl).

1 NV-26B Manual Loader, and observes the controller output at 100%.

21 (Step 2.c) Wait 2 minutes.

The operator waits 2 minutes before continuing.

p 2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 10 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 22 (Step 2.d) CLOSE 1 NV-26B The operator rotates the (Ui Excess L/D Hx Outlet adjust knob counter Cntrl).

clockwise on 1 NV-26B Manual Loader, and observes the controller output at 0%.

23 (Step 3) Check the following The operator observes the valves

- CLOSED:

1 NV-94AC Red status light LIT, Green status light is 1NV-94AC (Ui NC Pumps OFF.

Seal Water Return Cont Inside Isol)

The operator observes the 1 NV-95B Red status light 1NV-95B (Ui NC Pumps LIT, Green status light is Seal Water Return Cont OFF.

Outside Isol).

The operator proceeds to Step 3 RNO.

24 (Step 3 RNO) IF both The operator proceeds to valves open, THEN GO TO Step 10.

Step 10.

25 (Step 10) Check reactor -

The operator observes that SUBCRITICAL.

all Rods are fully inserted; and determines that the reactor is subcritical.

  • 26 (Step 1 1) OPEN the The operator presses the following valves:

OPEN pushbutton for 1 NV 24B, and observes the Red 1NV-24B (1C NC Loop To status light is LIT, Green Excess L/D Hx Isol) status light is OFF.

1 NV-25B (1 C NC Loop To The operator presses the Excess L/D Hx Isol).

OPEN pushbutton for 1 NV 25B, and observes the Red status light is LIT, Green status light is OFF.

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 11 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 27 (Step 12) Slowly OPEN The operator rotates the 1 NV-26B (Ui Excess L/D adjust knob clockwise on Hx Outlet Cntrl) while 1 NV-26B Manual Loader, maintaining Excess letdown and observes the controller Hx temperature less than output at 100%.

200°F.

28 (Step 13) Check the following valves

- CLOSED:

The operator observes the 1NI-185A (iA ND Pump iNI-i85A Green status light Suction From Cont Sump LIT, Red status light is OFF.

Isol)

The operator observes the iNl-i 848 (lB ND Pump 1NI-185A Green status light Suction From Cont Sump LIT, Red status light is OFF.

Isol).

29 (Step 14) Notify Chemistry The operator contacts that excess letdown is in Chemistry and notifies them

service, that Excess letdown is in service.

Cue Chemistry acknowledges 2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 12 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 30 (Step 15) WHEN time The operator contacts allows, THEN notify Engineering and notifies engineering to document them that Excess letdown is transients on letdown and in service.

charging.

Cue:

Engineering acknowledges.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

20i4 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Page 13 of 14 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM E Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM E NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

With Unit 1 performing a reactor startup, the plant trips due to an electrical malfunction.

The crew is currently in EPI1IAI5000IES-O.i (Reactor Trip Response).

INITIATING CUE:

The CRS has directed you to perform AP111A15500115 (Loss of Vital or Aux Control Power), while the crew continues with ES-O.1.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM F 2014 Systems

- Control Room JPM F (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 1 1 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Emergency Borate the NCS JPM No.:

2014 Systems

- Control Room JPM F (Alternate Path)

K/A

Reference:

APE 024 AA2.04 (3.4/4.2)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout AP111A15500138 marked up through Step 11.

Initial Conditions:

With the plant at power, a Reactor Makeup System failure has resulted in an automatic Control Rod insertion.

MCB Annunciator 1AD-2, A9, CONTROL ROD BANK LO LIMIT, has alarmed.

The crew has entered AP/1/A15500/38 (Emergency Boration) and completed the procedure through Step 11.

The 1 B BA Transfer Pump is OOS.

Initiating Cue:

The CRS has directed you to initiate Emergency Boration starting with Step 12 of AP/1/A/5500138 (Emergency Boration).

Task Standard:

The operator establishes Emergency Boration flow from the FWST.

Required Materials:

None 2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 3 of 1 1 Form ES-C-i Job Performance Measure Worksheet General

References:

OP/1/A/6100/O1O C (Annunciator Response for Panel 1AD2), Rev.

63 AP111A15500138 (Emergency Boration), Rev. 11 OP/1/A/6100!O1O L (Annunciator Response for Panel 1AD-2), Rev.

76 Handouts:

API1IAI5500I38 (Emergency Boration), marked up through Step 11.

Time Critical Task:

NO Validation Time:

5 minutes 2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 4 of 1 1 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset to IC-39 (100% Steady-state) 2.

Place Simulator in Run and acknowledge Annunciator Alarms.

3.

Enter MALF-NCOO1

= 1010, ramped at 180 seconds, and allow Controls Rods to auto insert until MCB Annunciator 1AD-2, A9, has alarmed.

4.

Stabilize plant at < 100% power (NOTE; AFD is NOT within Spec).

5.

Insert the following:

LOA-NV044, BORIC ACID XFR PUMP lB RACKOUT (Control Switch in STOP) 6.

Place the 1A BA Transfer Pump Control Switch in AUTO with Pump OFF.

7.

Perform Steps 1-11 of AP/1/A!5500/38.

8. Acknowledge alarms and Freeze the Simulator.

OR 1.

Reset Simulator to Temporary Snap IC-249 (April, 2014) 2.

Place Red Tag Sticker on 1 B Boric Acid Transfer Pump.

3.

Momentarily place Simulator in Run for at LEAST 30 seconds to acknowledge alarms.

4.

Leave Simulator in FREEZE until operator is ready to begin.

NOTE: The Simulator Instructor will be required to insert a Malfunction immediately after JPM Step 5.

2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 5 of 1 1 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial Conditions/Cue (Last Page of this JPM), and Handout AP111A15500138 marked up through Step 11.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT Simulator Instructor NOTE: Leave Simulator in FREEZE until operator is ready to begin.

(Step 12) Initiate The operator observes Red emergency boration as status light LIT, Green follows:

status light OFF for the 1 B NV Pump.

(Step i2.a) Check iAor lB NV pump-AVAILABLE 2

(Step 12.b) Check any NV The operator observes Red pump-ON.

status light LIT, Green status light OFF for the 1 B NV Pump, and that amperage is at normal running amps.

3 (Step 12.c) Check the following boric acid system component AVAILABLE.

The operator observes Boric Acid Storage Tank 1 NVP-5740 and determines that 1 BAT level is 64%. (Or equivalent, i.e. observes the OAC)

Boric Acid Transfer pump.

The operator observes 1NVP-6070 and determines that 2 BAT level is 62%.

(Or equivalent, i.e. observes the OAC)

The operator observes Green status light LIT, Red status light OFF for the 1A BA Transfer Pump.

2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 6 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQU IRED FOR UNSAT 4

(Step 12.d) OPEN 1NV-The operator presses the 265B (Boric Acid to NV OPEN pushbutton for 1 NV Pumps).

265B, and observes Red status light LIT, Green status light OFF.

5 (Step i2.e) Ensure a boric The operator rotates the acid transfer pump is Control Switch to START running.

for the iA BA Transfer Pump, and observes Red status light LIT, Green status light OFF.

Simulator Instructor:

2 Seconds after the operator starts the IA BA Transfer Pump, Insert MAL-ELXA (IELXA De energizes causing a loss of the IA BA Transfer Pump [Via IEMXA])

NOTE: lAD-Il, A2 and A3 will alarm on the loss of IELXA. The operator will address these ARPS and dispatch an AO to locally investigate.

Cue:

If the operator announces these alarms to the CRS, as the CRS, state that another operator will address the ARPs.

6 (Step 1 2.f) Check boration flow using one of the following methods:

The operator observes IF i NV-265B is open, 1 NVP-5440 (Or equivalent, THEN check i.e. OAC) observes 5 gpm, EMERGENCY BORATION and determines that FLOW ESTABLISHED.

Emergency Boration Flow is NOT established, and proceeds to RNO.

(ALTERNATE PATH) 2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 7 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 7

(Step 12.f RNO) Perform The operator recognizes the following:

that the 1 B BA Transfer Pump is OOS, and (Step 1 2.f RNO 1) Start proceeds.

second boric acid transfer pump.

  • 8 (Step 12.f RNO 2) IF boration flow cannot be established, THEN align NV pump suction to FWST as follows:

(Step 12.f RNO 2.a) OPEN the following valves:

The operator observes that the 1 NV-221A status lights 1NV-221A (NV Pumps Suct are both OFF.

From FWST)

The operator presses the OPEN pushbutton for 1 NV 222B, and observes Red 1 NV-222B (NV Pumps Suct status light LIT, Green From FWST).

status light OFF.

NOTE:

The opening of INV-222B will satisfy the Critical nature of the step.

2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 8 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U

  • 9 (Step 12.f RNO 2.b) CLOSE The operator observes that the following valves:

the 1 NV-i 41A status lights are both OFF.

1NV-i4lA (VCT Outlet Isol)

The operator presses the CLOSE pushbutton for 1NV-i42B (VCT Outlet 1NV-142B, and observes lsol).

Green status light LIT, Red status light OFF.

NOTE:

The Closing of INV-142B will satisfy the Critical nature of the step.

10 (Step 12.f RNO 2.c) GO TO The operator proceeds to Step 15 Step 15.

1 1 (Step 15) Align Normal Charging flowpath as follows:

(Step 15.a) Ensure one of the following NC loop isolation valves is OPEN:

1 NV-i 3B (NV Supply to A The operator observes the NC Loop Isol) 1NV-i3B Red status light LIT, Green status light OFF.

OR 1 NV-i 6A (NV Supply to D NC Loop Isol).

COMMENTS REQUIRED FOR UNSAT 2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

Appendix C Page 9 of 1 1 Form ES-C-i PERFORMANCE INFORMATION 12 (Step 15.b) Check both of the following valves-OPEN:

1 NV-244A (Charging Line The operator observes the Cont Outside Isol)

NV Graphic on the OAC and determines that 1 NV 244A status lights are OFF.

1 NV-245B (Charging Line Cont Outside Isol).

The operator observes the INV-245B Red status light LIT, Green status light OFF.

S/U COMMENTS REQUIRED FOR UNSAT STEPS ELEMENTS STANDARD Terminating Cue:

STOP TIME:

Evaluation on this JPM is complete.

2014 Systems

- Control Room JPM F NUREG 1021, Revision 9

AppendixC Page lOof 11 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM F Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems - Control Room JPM F NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

With the plant at power, a Reactor Makeup System failure has resulted in an automatic Control Rod insertion.

MCB Annunciator 1AD-2, A9, CONTROL ROD BANK LO LIMIT, has alarmed.

The crew has entered API1IAI5500I38 (Emergency Boration) and completed the procedure through Step ii.

The 1 B BA Transfer Pump is OOS.

INITIATING CUE:

The CRS has directed you to initiate Emergency Boration starting with Step 12 of AP!1IA!5500138 (Emergency Boration).

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM G 2014 Systems

- Control Room JPM G (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 12 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Isolate the NV S/I Flowpath While JPM No.:

2014 Systems

- Control Terminating Safety Iniection Room JPM G (Alternate Path)

K/A

Reference:

E02 EA1.1 (4.0/3.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Ensure Handout I is placed on CRS Desk.

Provide Candidate with Initial Conditions/Cue (Last Page of this JPM).

Initial Conditions:

A plant transient at Unit 1 has resulted in a reactor trip from power and a Saf ty I jection actuati n.

Safety Inj Dtio Termination C Iteria has been met and the crew is implemen ng

P/1/AI5000/E -1.1 (Safety Injection Termination).

Initiating Cue:

The CRS has directed you to isolate the NV S/I flowpath in accordance with Step 6 of EP/1/A15000/ES-1.1 (Safety Injection Termination).

Task Standard:

The operator will attempt to isolate NV S/I flow per EP/i/A/500!ES-i.1, recognize that this cannot be accomplished and complete Generic 8 to realign the NV system for normal charging, close the SI Injection valves and then maintain a minimum amount of charging flow to avoid overheating the NV Pumps.

Required Materials:

None 2014 Systems - Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 3 of 12 Form ES-C-i Job Performance Measure Worksheet General

References:

EPI1IAI5000IES-i.1 (Safety Injection Termination), Rev 26 EPIiIAI5000IG-i (Generic Enclosures), Rev 36 Handouts:

Handout 1: EPI1IAI5000IES-1.1 (Safety Injection Termination) marked up through Step 5, open on the CRS Desk.

Handout 2: Blank Copy of EPI1IAI5000IG-1 (Generic Enclosures),

Generic Enclosure 18 (Aligning Normal Charging With NV Recirc Path Isolated).

Time Critical Task:

NO Validation Time:

12 minutes 2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 4 of 12 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset the Simulator to IC-39 (100%)

2.

Insert MAL-ISEO06A = BLK_BOTH (Failure of MSI Signal Train A)

Insert MAL-ISEOO6B = BLK_BOTH (Failure of MSI Signal Train B)

Insert MAL-SM009 (Main Steam Header Break)

(Event requiring SI initially, but as transient progresses will lead to implementation of SI Termination).

3.

Manually close MSIVs when NC pressure decreases to less than 2000 psig.

4.

Ensure that 1NV-i5OB and 1NV-151A are CLOSED (Simulating closure of valves on E-0 Foldout Page requirement to close. NOT re-opened per Foldout Page as of yet) 5.

Insert REM-NVO151A = 0 (1NV-151A (Ui NV Pump Recirc Iso!) is stuck CLOSED).

6.

Perform all EP actions up to through step 5 of EP/1/A15000/ES-i.1, and markup CRS Desk copy of procedure.

7.

Ensure that NC System pressure is 2000 psig and rising.

8.

Stabilize plant conditions and Freeze the Simulator OR 1.

Reset Simulator to Temporary Snap IC-227 (April, 2014) 2.

Momentarily place Simulator in Run to acknowledge alarms.

3.

Leave Simulator in FREEZE until operator is ready to begin.

NOTE:

During the performance of this JPM, the Simulator Instructor will need to monitor unrelated alarms and silence as needed.

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 5 of 12 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Ensure Handout I is placed on CRS Desk.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT Simulator Instructor NOTE: Leave Simulator in FREEZE until operator is ready to begin.

(Step 6) Isolate NV S/I The operator observes the flowpath as follows:

1NV-221A Red status light is LIT, and Green status (Step 6.a) Check the light is OFF.

following valves

- OPEN:

1 NV-221A (Ui NV Pump The operator observes the Suct From FWST Iso!)

1NV-222B Red status light is LIT, and Green status 1 NV-222B (Ui NV Pump light is OFF.

Suct From FWST Isol).

2 (Step 6.b) Check the The operator observes the following valves

- OPEN:

1NV-150B Green status 1NV-150B (Ui NV Pump light is LIT, and Red status Recirc Isol) light is OFF.

1NV-i5lA(U1 NV Pump The operator observes the Recirc Iso!).

1NV-151A Green status light is LIT, and Red status light is OFF.

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

(Step 6.b RNO b) Perform the following:

(Step 6.b RNO b.1) OPEN valves.

(Step 6.b RNO b.2) IF both valves open, THEN (Step 6.b RNO b.3)

Dispatch operator to OPEN affected valve(s).

1 NV-i 50B (aux bldg, 7i6+8, HH-55, room 627, NV pump room iA, west of pump motor) 1NV-i5iA (aux bldg, 71 6+9, HH-55, room 627, NV pump room 1A, west of pump motor).

The operator presses the 1NV-150B OPEN pushbutton and observes the Red status light is LIT, and Green status light is OFF.

The operator presses the 1NV-i5iA OPEN pushbutton and observes the Green status light remains LIT, and Red status light remains OFF.

(Alternate Path)

The operator recognizes that both valves are NOT open and continues.

The operator contacts an AO and directs that they open 1NV-151A locally.

Cue:

The AO acknowledges.

Appendix C Page 6 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 3

5 2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 7 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 6

(Step 6.b RNO b.4) Realign The operator proceeds to charging PER Generic Enclosure 18.

EPI1IAI5000/G-i (Generic Enclosures) Enclosure 18 Examiner Note (Aligning Normal Charging With NV Recirc Path When the operator Isolated) locates the G-1 Notebook, orovide the ooerator with 7

(Enclosure 18, Step 1)

The operator observes Check VI header pressure

0VIP-5090 and determines GREATER THAN 60 PSIG.

that VI header pressure is 108 psig.

8 (Step 2) Check NC pump The operator observes seal injection flow 1 NVP-5300, 5310, 5320 GREATER THAN OR and 5330 and determines EQUAL TO 6 GPM TO that Seal Injection flow to EACH NC PUMP.

each NCP is greater than 6 gpm.

9 (Step 3) GO TO Step 8.

The operator proceeds to Step 8.

  • 10 (Step 8) CLOSE 1 NV-241 The operator adjusts the (Ui Seal Water Inj Flow 1NV-241 Manual Loader Control).

counter-clockwise until the Manual Loader output equals 0%.

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 8 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQU IRED FOR UNSAT 1 1 (Step 9) Check one of the The operator observes the following valves

- OPEN:

INV-13B Red status light is 1NV-13B (Ui NVSupplyTo LIT and the Green status 1A NC Loop Isol) ig i5 OR 1NV-16A (Ui NV Supply To Examiner NOTE 1D NC Loop Isol)

INV-16A is CLOSED 12 (Step 10) Check 1NV-2iA The operator observes the (Ui NV Supply to Ui Aux iNV-2iA Green status light PZR Spray Isol)

- CLOSED.

is LIT, and the Red status light is OFF.

  • 13 (Step 1 1) OPEN the The operator presses the following valves:

1 NV-244A OPEN 1NV-244A lJ Ch pushbutton and observes Hdr Cont Outside Isol) e e

5 a us ig is Green status light OFF.

1 NV-245B (Ui Charging The operator presses the Hdr Cont Outside Isol).

i NV-245B OPEN pushbutton and observes the Red status light is LIT, Green status light OFF.

  • 14 (Step 12) Establish The operator presses the charging pump minimum Blue M pushbutton on the flow as follows:

1 NV-238 SLIMS.

(Step 12.a) Place 1NV-238 (Ui Charging Hdr Control) controller in manual.

15 (Step 12.b) Check NC The operator observes NC pressure

- LESS THAN System pressure is greater 1800 PSIG.

than 1800 psig.

20i4 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 9 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 16 (Step i2.b RNO b) Perform The operator presses the the following:

1 NV-238 SLIMS OUTPUT (Step 12.b RNO b.1) Fully Raise pushbutton until OPEN 1NV-238 (Ui SLIMS output is at 100%.

Charging Hdr Control).

17 (Step 12.b RNO b.2) IF The operator recognizes 1 NV-238 cannot be that this step is NOT operated from the Control applicable and continues.

Room 18 (Step i2.b RNO b.3) IF NC The operator observes NC pressure less than 2000 System pressure is greater PSIG than 2000 psig.

  • 19 (Step i2.b RNO b.4)

The operator adjusts the THROTTLE 1NV-24i (Ui 1NV-241 Manual Loader Seal Water Inj Flow Control) clockwise until the Manual to 50% OPEN.

Loader output equals 50%.

20 (Step 12.b RNO b.5) IF The operator recognizes 1 NV-24i cannot be that this step is NOT operated from the Control applicable and continues.

Room 21 (Step 12.b RNO b.6) GO The operator proceeds to TOStepl3.

Step 13.

  • 22 (Step 13) CLOSE the The operator presses the following valves:

1 NI-9A CLOSE pushbutton and observes the Green 1NI-9A (NC Cold Leg Inj From NV) status light is LIT, Red status light is OFF.

1NI-1OB (NC Cold Leg Inj The operator presses the From NV).

1NI1OB CLOSE pushbutton and observes the Green status light is LIT, Red status light is OFF.

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 10 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 23 (Caution prior to Step 14)

The operator reads the Failure to maintain charging Caution and proceeds.

flow above 80 GPM will result in inadequate NV pump miniflow protection.

This limit applies to all subsequent EPs.

  • 24 (Step 14) THROTTLE The operator observes charging nd seal injction Charging flow (1NVP5630) to maintain the following:

and adjusts to be between Charging flow between 80 80-200 gpm.

GPM and 200 GPM Seal injection flow 6-10 The operator observes GPM per NC pump.

1NVP-5300, 5310, 5320 and 5330 and adjusts Seal Injection flow to each NCP is between 6-10 gpm.

25 (Step 15) RETURN TO The operator reports that procedure and step in NV S/I Flow has been effect.

isolated per Generic 8.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Page 11 of 12 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM G Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM G NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

A plant transient at Unit 1 has resulted in a reactor trip from power and a Safety Injection actuation.

Safety Injection Termination criteria has been met and the crew is implementing EP/i IAJ5000IES-1.1 (Safety Injection Termination).

INITIATING CUE:

The CRS has directed you to isolate the NV S/I flowpath in accordance with Step 6 of EPI1IAI5000IES-1.1 (Safety Injection Termination).

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet SIM JPM H 2014 Systems

- Control Room JPM H (Rev_071714)

NUREG 1021, Revision 9

Appendix C Page 2 of 12 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

KC Pump Functional Verification JPM No.:

2014 Systems

- Control Room JPM H K/A

Reference:

008 Al.01 (2.8/2.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom Simulator X

Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

Initial Conditions:

Unit 1 is at 100% power.

The 1A1 KC Pump was previously tagged out for an Oil Change.

The R&R has been cleared and the Breaker Racked In.

AO (Mike) is at the 1A1 KC Pump ready for pump testing, with a copy of the procedure in hand.

The lA RN Pump is running for OTG testing later today.

Initiating Cue:

The CRS has directed you to conduct a Functional Verification of the 1A1 KC Pump in accordance with Enclosure 4.5 (KC Pump Functional Verification (Bump Start)) of OP/i/A16400/005 (Component Cooling Water System).

Task Standard:

The operator will conduct a Functional Verification of the A Train KC Pumps in accordance with Enclosure 4.5, KC Pump Functional Verification (Bump Start), of OP/i /A/6400/005, Component Cooling Water System, using the 1A1 KC Pump.

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 3 of 12 Form ES-C-i Job Performance Measure Worksheet Required Materials:

None General

References:

OPI1IAJ6400I005 (Component Cooling Water System), Rev 102 Handouts:.5 (KC Pump Functional Verification (Bump Start)) of OP/i /A164001005 (Component Cooling Water System) marked up as follows:

Step 21 Initialed.

Step 3.1 Checkbox checked.

Step 3.2 Section 3.3 Checkbox checked.

Time Critical Task:

NO Validation Time:

8 minutes 2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 4 of 12 Form ES-C-i Job Performance Measure Worksheet SIMULATOR OPERATIONAL GUIDELINES 1.

Reset simulator to lC-39, 100% Power 2.

Place in RUN and allow time to stabilize 3.

Ensure B Train of equipment is in service.

4.

Start the iA RN Pump.

5.

Freeze the Simulator OR i.

Reset Simulator to Temporary Snap IC-251 (April, 2014).

2.

Momentarily place Simulator in Run to acknowledge alarms/Reset SLIMS.

3.

Leave Simulator in FREEZE until operator is ready to begin.

2014 Systems - Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 5 of 12 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Step 3.3) A Train KC Pump Functional Verification (Step 3.3.1) IF RN NOT The operator observes RN available to supply 1A KC System and determines that Pump Motor Coolers AND sufficient RN System flow 1A KC HX exists to supply 1A KC Pump Motors and HX.

2 (Note prior to Step 3.3.2)

The operator reads the Operation of 1KC-149 (A Note and rwoceeds KF HX Outlet Flow) or 1KC-156 (B KF HX Outlet Flow) to maintain KCto KFHX flow less than 500 gpm will result in erratic flow control.

  • 3 (Step 3.3.2) Adjust B Train The operator observes KC flow to 6000-7000 gpm I KCP-5540 at 5200 gpm.

by throttling one or more of the following:

The operator throttles one 1 KC-1 49 (A KF HX Outlet or more valves as Flow) necessary to achieve 6000-7000 gpm of B Train KC 1KC-156 (B KF HX Outlet flow.

Flow) 1 KC-56A (KC to A ND HX) 1KC-81B (KC to B ND HX) 2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 6 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Step 3.3.3) IF desired to The operator directs AO to operate iAl KC Pump for vent iAi KC Pump using functional, perform the 1KC-21.

following:

(Step 3.3.3.1) Vent iAl KC Pump using 1KC-2i (1A1 cue:

KC Pump Overflow Isol).

AO (Mike) reports IAI KC Pump has been vented.

  • 5 (Step 3.3.3.2) Select Auto The operator rotates on 1 KC-51A (Train A Recirc Control Switch clockwise to AUTO on 1KC-51A.

Isol).

6 (Step 3.3.3.3) Check 1 KC-The operator observes the 5iA (Train A Recirc Isol) i KC51A Red status light LIT, and Green status light open.

OFF.

(Note prior to Step 3.3.3.4)

The operator reads the KC Pumps should operate Note, and proceeds.

at least 10 seconds.

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 7 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 8 (Step 3.3.3.4) Start iAi KC The operator makes Pump announcement concerning pump start.

Icaminr Nnt I ri I

NU I a critical Sffifl.

The operator presses the lAi KC Pump START pushbutton.

The operator observes:

Red status light LIT for iAl KCPump.

Motor amps increase.

1 KCP-5530 increases to 2500 gpm.

MCB Annunciator lAD-b, B-i, NCDT HX OUTLET HI FLOW, may momentarily alarm as an expected alarm on pumps start.

txaminer Note:

As flow increases in A KC Train, IKC-5lAwilI automatically close.

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 8 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 9 (Step 3.3.3.5) AFTER 10 After 10 seconds of pump seconds elapsed AND run time, the operator running current has rotates 1KC-51A Control stabilized, select CLOSE on Switch counter-clockwise to 1 KC-51A (Train A Recirc CLOSE position.

Isol).

  • 10 (Step 3.3.3.6) Stop 1A1 KC The operator depresses the Pump iAl KC Pump STOP pushbutton.

The operator observes:

Green status light UT for lAi KCPump.

Motor amps decrease to 0.

1 KCP-5530 decreases to 0 gpm.

1 1 (Step 3.3.3.7) Check NO The operator directs AO to reverse rotation of 1A1 KC check for reverse rotation of Pump.

pump.

12 (Step 3.3.4) IF desired to The operator recognizes operate 1A2 KC Pump for that it is NOT desired to functional operate 1A2 KC Pump, and proceeds.

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 9 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 13 (Note prior to Step 3.3.5)

The operator reads the Operation of 1 KC-1 49 (A Note, and proceeds.

KF HX Outlet Flow) or 1 KC 156 (B KF HX Outlet Flow) to maintain KC to KF HX flow less than 500 gpm will result in erratic flow control.

  • 14 (Step 3.3.5) Adjust B Train The operator throttles the KC flow as desired by valve previously throttled throttling one or more of the open in Step 3.3.2 as following:

necessary to achieve 5200 gpm of B Train KC 1KC-149 (A KF HX Outlet flow (original flowrate) on Flow) 1 KCP5540.

1 KC-156 (B KF HX Outlet Flow) 1 KC-56A (KC to A ND HX) 1KC-818 (KCto B ND HX) 15 (Step 3.3.6) Check the following open:

I KC-394A (1A NC Pump The operator observes Thermal Barrier Outlet Isol) valves and notes that Red 1 KC-345A (1 B NC Pump status light is LIT, and the Thermal Barrier Outlet Isol)

Green status light is OFF for each valve.

1KC-364B (1C NC Pump Thermal Barrier Outlet Isol) 1KC-413B (iD NC Pump Thermal Barrier Outlet Isol) 2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page 10 of 12 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 16 (Step 3.3.7) If it is desired to The operator places an NA stop 1A RN Pump in this step.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Page ii of 12 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems

- Control Room JPM H Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems

- Control Room JPM H NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

Unit 1 is at 100% power.

The 1A1 KC Pump was previously tagged out for an Oil Change.

The R&R has been cleared and the Breaker Racked In.

AO (Mike) is at the 1A1 KC Pump ready for pump testing, with a copy of the procedure in hand.

The 1A RN Pump is running for OTG testing later today.

INITIATING CUE:

The CRS has directed you to conduct a Functional Verification of the 1A1 KC Pump in accordance with Enclosure 4.5 (KC Pump Functional Verification (Bump Start)) of OP/i /A/64001005 (Component Cooling Water System).

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet In-Plant JPM I Unit I 2014 Systems In-Plant JPM I (Rev_071814)

NUREG 1021, Revision 9

Appendix C Page 2 of 14 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Shift Seal Iniection Filters JPM No.:

20i4 Systems In-Plant JPM I

K/A

Reference:

003 A2.02 (3.7/3.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

X Actual Performance:

Classroom Simulator Plant X

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidatewith Initial ConditionslCue (Last Page ofthis JPM), and Handout 1.

RP has been informed that Seal Injection Filter lB will be placed in service.

All initial conditions have been verified and R & Rs have been evaluated.

Initiating Cue:

The CRS directs you to place i B seal injection filter in service by performing OP/1/AI6200IOOiC (Chemical And Volume Control System Filters) Enclosure 4.2 (Shifting Seal Water Injection Filters and Assisting Maintenance in Change Out), Section 3.5.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

Task Standard:

The operator will place the 1 8 Seal Filter in service in accordance with Section 3.5 of Enclosure 4.2 of OPIi/A/6200/OOiC.

201 4 Systems In-Plant JPM I NUREG 1 02i

, Revision 9

Appendix C Page 3 of 14 Form ES-C-i Job Performance Measure Worksheet Required Materials:

PPE (Hardhat, Safety Glasses, Hearing Protection, Safety Shoes etc.)

General

References:

OPIiIAI6iOOIOiO H (Annunciator Response for Panel 1AD-7), Rev 64 OP/i/A/6200/00i C (Chemical and Volume Control System Filters), Rev 33 Handouts:

Handout 1: Enclosure 4.2 (Shifting Seal Injection Filters and Assisting in Maintenance Change out) of OP/i/A16200/OOi C (Chemical and Volume Control System Filters); marked up through Step 3.4 to select the performance of Section 3.5.

Time Critical Task:

NO Validation Time:

16 minutes 2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 4 of 14 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial Conditions!Cue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 1

(Caution prior to Step 3.5.1)

The operator reads the Placing Seal Water Injection Caution and proceeds.

Filter in service could result in a Boron dilution of the NC System. R.M.

2 (Step 3.5.1) Notify The operator recognizes that Radwaste Chemistry of Radwaste has been notified input to WEFT (Waste (Initial Conditions), and Evaporator Feed Tank) and proceeds.

to monitor tank levels while draining.

3 (Step 3.5.2) Notify Shift RP The operator recognizes that that 1 B Seal Water Injection RP has been notified (Initial Filter will be placed in Conditions), and proceeds.

service and to monitor for changing dose rates in affected areas. {SOER 01 01 Recommendation}.

4 (Step 3.5.3) Ensure closed The operator attempts to 1 NV-307 (1 B Seal Water rotate the i NV-307 Injection Filter Drn Isol).

Handwheel in the clockwise direction, and recognizes that the Handwheel will not rotate.

Cue When Handwheel is clockwise, Handwhe NOT move 2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 5 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 5 (Step 3.5.4) Open:

For each of the following:

iNV-306 (lB Seal 1NV-306 Water Injection Filter Overflow & Vent lsol) 1 NV309 1NV-304 1 NV-309 (Unit 1 Seal Water Injection Filter The operator rotates the Drain To WEFT Isol)

Handwheel in the counter clockwise direction until the 1NV-304 (lB Seal Handwheel stops rotating.

Water Injection Filter Flush Supply Isol)

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

  • 6 (Step 3.5.5) Throttle open The operator rotates the 1 NV-303 (Unit 1 Seal Water 1 NV-303 Handwheel in the Injection Filter Flush Supply counter-clockwise direction.

Isol) until one of the following met:

I Cue:

Water observed in overflow I When Handwheel is rotated sight glass (1NVFG611O) counter-clockwise, water is (733+6, JJ53 Wall) observed in sight glass.

OR The operator stops valve WEFT (Waste Evaporator manipulation.

Feed Tank) level trend (M2A0574) increasing 2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 6 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 7 (Step 3.5.6) HOLD until For each of the following:

water observed in overflow sight glass OR WEFT 1 NV309 (Waste Evaporator Feed 1 NV306 Tank) level trend 1 NV303 increasing, THEN close:

1NV-304 The operator rotates the 1NV-309 (Unit 1 Seal Handwheel in the clockwise Water Injection Filter direction until the Handwheel Drain To WEFT Isol) stops rotating.

1 NV-306 (1 B Seal Water Injection Filter Cue*

Overflow & Vent Isol) 1 NV-303 (Unit 1 Seal When Handwheel is rotated Water Injection Filter clockwise, Handwheel Flush Supply Isol) rotates, and then stops 1 NV-304 (1 B Seal (1r full travel).

Water Injection Filter Flush Supply Isol) 8 (Step 3.5.7) Establish and The operator establishes maintain constant communication with the Unit communication between 1 BOP.

Control Room and operators in the field while Cue:

operating Seal Water Injection Filter isolation Acknowledge as the BOP

valves, via radio.

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 7 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Step 3.5.8) Notify Control The operator contacts the Room of the following:

Control room and makes the Monitor VCT level while notifications.

shifting/draining Seal Water Injection filters Continuously monitor Cue:

NCP seal flows Acknowledge as the BOP.

Place WEFT level (M2A0574) on trend and monitor to verify proper filter isolation (potential leakby to WEFT). {PIP M-i 1-6538}

10 (Note prior to Step 3.5.9)

The operator reads the Note Due to the potential for and proceeds.

moving foreign material to NC Pumps, the following steps will slowly and alternately throttle the inlet valves until both fully opened. {PIP M-09-0950}

  • 1 1 (Step 3.5.9) Perform the The operator rotates the following:

1 NV-491 Handwheel in the counter-clockwise direction (Step 3.5.9.1) Slowly 90° throttle 1 NV-491 (1 B Seal Water Injection Filter Inlet Isol) 1/4 of a turn open OR Cue enough to initially break Handwheel is rotated valve off seat.

counter-clockwise 90 2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 8 of 14 Form ES-C-i PERFORMANCE INFORMA11ON STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 12 (Step 3.5.9.2) Slowly The operator rotates the throttle 1NV-246 (18 Seal 1NV-246 Handwheel in the Water Injection Filter Inlet counter-clockwise direction Isol) 1/8 of a turn open.

45°.

Cue:

Handwheel is rotated counter-clockwise 45°.

13 (Step 3.5.9.3) WHEN either The operator reads the step, valve in Step 3.5.9.1 or and proceeds.

3.5.9.2 reaches full open, slowly open other valve until full open.

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 9 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 14 (Step 3.5.9.4) Repeat Steps The operator rotates the 3.5.9.1 and 3.5.9.2 until 1NV-491 Handwheel in the both valves full open.

counter-clockwise direction, and/or rotates the 1 NV-246 Handwheel in the counter clockwise direction.

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

The operator rotates the 1 NV-491 Handwheel in the counter-clockwise direction, and/or rotates the 1 NV-246 Handwheel in the counter clockwise direction.

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

15 (Step 3.5.10) IF directed to The operator recognizes that this step after 18 Seal this Step does NOT apply, Water Injection Filter has and proceeds.

been filled, vented, and checked for leaks by aminer Note:

Maintenance (Step 3.8.13.11) he operator performs s step, rather than acing an NA, provide es as appropriate.

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 10 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 16 (Step 3.5.11) Slowly open The operator rotates the 1NV-492 (lB Seal Water 1NV-492 Handwheel in the Injection Filter Outlet Isol).

counter-clockwise direction.

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

17 (Step 3.5.12) Establish flow The operator reads the Note through Seal Water and proceeds.

Injection Filter 1 B as follows:

(Note prior to Step 3.5.12.1) IF all NC Pump seal cooling is lost, seal injection should remain isolated if NC Pump Lower Bearing or Seal Outlet temperatures have exceeded their operating limits. {ERG DW94-il}

18 (Step 3.5.12.1) IF all NC The operator recognizes that Pump cooling has been lost this Step does NOT apply, (thermal barrier and seal and proceeds.

injection) 2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page ii of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 19 (Step 3.5.12.2) IF NC Pump The operator contacts the Ui Seal Injection is less than 6 BOP and requests Seal gpm per pump Injection flow rate to each NCP.

Cue:

As the UI BOP report that the Seal Injection flow to each NCP is 8 gpm.

20 (Note prior to Step 3.5.12.3)

The operator reads the Note As 1 B Seal Water Injection and proceeds.

Filter flowpath is established, a noted drop in If operator observes D/P DP should occur on 1A Seal gauges.

Water Injection Filter

{PIP M1310088}

Cue:

IA Filter DP is 41 PSID.

lB Filter DP is I PSID.

21 (Step 3.5.12.3) IF NC Pump The operator slowly rotates seal injection flow is greater the 1 NV-247 Handwheel in than 6 gpm per pump, the counter-clockwise slowly open 1 NV-247 (1 B direction.

Seal Water Injection Filter Outlet Isol).

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

22 (Note prior to Step 3.5.12.4)

The operator reads the Note Seal Injection filter may and proceeds.

NOT indicate tiP when both Seal Injection filters are in service.

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 12 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 23 (Step 3.5.12.4) Check flow The operator observes indicated through lB Seal 1NVPG564O.

Water Injection Filter via presence of DP on Cue:

1 NVPG564O.

OR Filter DP is 5 PSID.

Monitor lB Seal Injection The operator reads the Step FilterP as 1A Seal and proceeds.

Injection Filter is removed from service.

Cue:

Another operator will continue with this procedure.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 13 of 14 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems In-Plant JPM I

Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

Unit i is operating at 100% power.

MCB Annunciator 1AD-7, NC PUMP SEAL INJ LO FLOW, has just alarmed.

It is planned to shift Seal Injection Filters.

Radwaste has already been informed they will receive waste input.

RP has been informed that Seal Injection Filter i B will be placed in service.

All initial conditions have been verified and R & Rs have been evaluated.

INITIATING CUE:

The CRS directs you to place lB seal injection filter in service by performing OP/i/A16200/OOiC (Chemical And Volume Control System Filters) Enclosure 4.2 (Shifting Seal Water Injection Filters and Assisting Maintenance in Change Out), Section 3.5.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet In-Plant JPM I Unit2 2014 Systems In-Plant JPM I (Rev_071814)

NUREG 1021, Revision 9

Appendix C Page 2 of 14 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Shift Seal Injection Filters JPM No.:

2014 Systems In-Plant JPM I K/A

Reference:

003 A2.02 (3.7/3.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

X Actual Performance:

Classroom Simulator Plant X

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

Task Standard:

The operator will place the 2B Seal Filter in service in accordance with Section 3.5 of Enclosure 4.2 of OP/2/A16200/OOiC.

20i4 Systems In-Plant JPM I

NUREG iO2i, Revision 9

Appendix C Page 3 of 14 Form ES-C-i Job Performance Measure Worksheet Required Materials:

PPE (Hardhat, Safety Glasses, Hearing Protection, Safety Shoes etc.)

General

References:

OPI2IAI6iOOIOiO H (Annunciator Response for Panel 2AD-7), Rev 55 0P121A162001001 C (Chemical and Volume Control System Filters), Rev 38 Handouts:

Handout 1: Enclosure 4.2 (Shifting Seal Injection Filters and Assisting in Maintenance Change out) of 0P12/A/6200/OOi C (Chemical and Volume Control System Filters); marked up through Step 3.4 to select the performance of Section 3.5.

Time Critical Task:

NO Validation Time:

16 minutes 2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 4 of 14 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Caution prior to Step 3.5.1)

The operator reads the Placing Seal Water Injection Caution and proceeds.

Filter in service could result in a Boron dilution of the NC System. R.M.

2 (Step 3.5.1) Notify The operator recognizes that Radwaste Chemistry of Radwaste has been notified input to WEFT (Waste (Initial Conditions), and Evaporator Feed Tank) and proceeds.

to monitor tank levels while draining.

3 (Step 3.5.2) Notify Shift RP The operator recognizes that that 2B Seal Water Injection RP has been notified (Initial Filter will be placed in Conditions), and proceeds.

service and to monitor for changing dose rates in affected areas. {SOER 01-01 Recommendation).

4 (Step 3.5.3) Ensure closed The operator attempts to 2NV-307 (2B Seal Water rotate the 2NV-307 Injection Filter Drn lsol).

Handwheel in the clockwise direction, and recognizes that the Handwheel will not rotate.

Cue:

When Handwheel is rotated clockwise, Handwheel will NOT move.

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 5 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 5 (Step 3.5.4) Open:

For each of the following:

2NV-306 (2B Seal 2NV-306 Water Injection Filter Overflow & Vent Isol) 2NV309 2NV-304 2NV-309 (Unit 2 Seal Water Injection Filter The operator rotates the Drain To WEFT Isol)

Handwheel in the counter clockwise direction until the 2NV-304 (2B Seal Handwheel stops rotating.

Water Injection Filter Flush Supply Isol)

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

  • 6 (Step 3.5.5) Throttle open The operator rotates the 2NV-303 (Unit 2 Seal Water 2NV-303 Handwheel in the Injection Filter Flush Supply counter-clockwise direction.

Isol) until one of the following met:

Cue:

Water observed in overflow When Handwheel is rotated sight glass (2NVFG6110) counter-clockwise, water is (733+5, JJ-59 Wall) observed in sight glass.

OR The operator stops valve WEFT (Waste Evaporator manipulation.

Feed Tank) level trend (M2A0574) increasing 2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 6 of 14 Form ES-C-I PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 7 (Step 3.5.6) HOLD until For each of the following:

water observed in overflow sight glass OR WEFT (Waste Evaporator Feed 2NV303 Tank) level trend 2NV309 increasing, THEN close:

2NV-306 2NV-304 2NV-303 (Unit 2 Seal The operator rotates the Water Injection Filter Handwheel in the clockwise Flush Supply Isol) direction until the Handwheel 2NV-309 (Unit 2 Seal stops rotating.

Water Injection Filter Drain To WEFT Isol)

Cue 2NV-306 (2B Seal Water Injection Filter When Handwheel is rotated Overflow & Vent Isol) clockwise, Handwheel 2NV-304 (2B Seal rotates, and then stops Water Injection Filter (After full travel).

Flush Supply lsol) 8 (Step 3.5.7) Establish and The operator establishes maintain constant communication with the Unit communication between 2 BOP.

Control Room and operators in the field while Cue:

operating Seal Water Injection Filter isolation Acknowledge as the BOP

valves, via radio.

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 7 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQU IRED FOR UNSAT (Step 3.5.8) Notify Control The operator contacts the Room of the following:

Control room and makes the Monitor VCT level while notifications.

shifting/draining Seal Water Injection filters Continuously monitor Cue:

NCP seal flows AND immediately notify Acknowledge as the BOP.

Operators in the field of any NCP seal injection flow changes.

Place WEFT level (M2A0574) on trend and monitor to verify proper filter isolation (potential leakby to WEFT). {PIP M-1 1-6538) 10 (Note prior to Step 3.5.9)

The operator reads the Note Due to the potential for and proceeds.

moving foreign material to NC Pumps, the following steps will slowly and alternately throttle the inlet valves until both fully opened. {PIP M-09-0950}

  • 11 (Step 3.5.9) Perform the The operator rotates the following:

2NV-491 Handwheel in the counter-clockwise direction (Step 3.5.9.1) Slowly 90°.

throttle 2NV-491 (28 Seal Water Injection Filter Inlet Isol) 1/4 of a turn open OR Cue:

enough to initially break Handwheel is rotated valve off seat. (2NV-491 counter-clockwise 900.

takes 12-14 turns to fully stroke valve) 2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 8 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 12 (Step 3.5.9.2) Slowly The operator rotates the throttle 2NV-246 (2B Seal 2NV-246 Handwheel in the Water Injection Filter Inlet counter-clockwise direction Isol) 1/8 of a turn open.

45°.

(2NV-246 takes 1.25

- 2 turns to fully stroke valve)

Cue:

Handwheel is rotated counter-clockwise 45°.

13 (Step 3.5.9.3) WHEN either The operator reads the step, valve in Step 3.5.9.1 or and proceeds.

3.5.9.2 reaches full open, slowly open other valve until full open.

2014 SystemsIn-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 9 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 14 (Step 3.5.9.4) Repeat Steps The operator rotates the 3.5.9.1 and 3.5.9.2 until 2NV-49i Handwheel in the both valves full open.

counter-clockwise direction, and/or rotates the 2NV-246 Handwheel in the counter clockwise direction.

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

The operator rotates the 2NV-491 Handwheel in the counter-clockwise direction, and/or rotates the 2NV-246 Handwheel in the counter clockwise direction.

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

15 (Step 3.5.10) IF directed to The operator recognizes that this step after 28 Seal this Step does NOT apply, Water Injection Filter has and proceeds.

been filled, vented, and checked for leaks by Examiner Note:

Maintenance (Step 3.8.13.11)

If the operator performs this step, rather than placing an NA, provide cues as appropriate.

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 10 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 16 (Step 3.5.11) Slowly open The operator rotates the 2NV-492 (2B Seal Water 2NV-492 Handwheel in the Injection Filter Outlet Isol).

counter-clockwise direction.

(2NV-492 takes 12-14 turns to fully stroke valve)

Cue:

When Handwheel is rotated counter-clockwise, Handwheel rotates, and then stops (After full travel).

17 (Step 3.5.12) Establish flow The operator reads the Note through Seal Water and proceeds.

Injection Filter 2B as follows:

(Note prior to Step 3.5.12.1) IF all NC Pump seal cooling is lost, seal injection should remain isolated if NC Pump Lower Bearing or Seal Outlet temperatures have exceeded their operating limits. {ERG DW 94-1 i}

18 (Step 3.5.12.1) IF all NC The operator recognizes that Pump cooling has been lost this Step does NOT apply, (thermal barrier and seal and proceeds.

injection) 2014 Systems In-Plant JPM I NUREG 1021, Revision 9

(Step 3.5.12.3) IF NC Pump seal injection flow is greater than 6 gpm per pump, slowly open 2NV-247 (2B Seal Water Injection Filter Outlet Isol). (2NV-247 takes 1.25-2 turns to fully stroke valve)

The operator slowly rotates the 2NV-247 Handwheel in the counter-clockwise direction.

When Handwheel is rotated 22 (Note prior to Step 3.5.12.4)

The operator reads the Note Seal Injection filter may and proceeds.

NOT indicate tP when both Seal Injection filters are in service.

Appendix C Page 11 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U I

COMMENTS I

REQUIRED

_FOR UNSAT 19 (Step 3.5.12.2) IF NC Pump The operator contacts the U2 Seal Injection is less than 6 BOP and requests Seal gpm per pump Injection flow rate to each NCP.

Cue:

As the U2 BOP report that the Seal Injection flow to each NCP is 8 gpm.

20 (Note prior to Step 3.5.12.3)

The operator reads the Note As 2B Seal Water Injection and proceeds.

Filter flowpath is established, a noted drop in If operator observes D/P DP should occur on 2A Seal gauges.

Water Injection Filter

{PIP M1310088}

Cue:

2A Filter DP is 41 PSID.

2B Filter DP is 1 PSID.

21 counter-clockwise, Handwheel rotates, and then stops (After full travel).

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Page 12 of 14 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 23 (Step 3.5.12.4) Check flow The operator observes indicated through 2B Seal 2NVPG5640.

Water Injection Filter via presence of DP on Cue:

2NVPG5640.

OR Filter DP is 5 PSID.

Monitor 28 Seal Injection The operator reads the Step FilterP as 2A Seal and proceeds.

Injection Filter is removed from service.

ue:

Another operator will ontinue with this rocedure.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems In-Plant JPM I

NUREG 1021, Revision 9

Appendix C Page 13 of 14 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems In-Plant JPM I Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems In-Plant JPM I NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

Unit 2 is operating at 100% power.

MOB Annunciators 2AD-7 J-i, NO PUMP SEAL INJ LO FLOW, and 2AD-7 L-4, SEAL WATER INJ FILTER HI D/P, have just alarmed.

It is planned to shift Seal Injection Filters.

Radwaste has already been informed they will receive waste input.

RP has been informed that Seal Injection Filter 2B will be placed in service.

All initial conditions have been verified and R & Rs have been evaluated.

INITIATING CUE:

The ORS directs you to place 2B seal injection filter in service by performing OP/2/A16200/OOi 0 (Chemical And Volume Control System Filters) Enclosure 4.2 (Shifting Seal Water Injection Filters and Assisting Maintenance in Change Out), Section 3.5.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet In-Plant JPM J 2014 Systems In-Plant JPM J (Rev_071814)

NUREG 1021, Revision 9

Appendix C Page 2 of 1 1 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Ensure Proper Response of Diesel JPM No.:

2014 Systems In-VI Compressors on Loss of VI Plant JPM J K/A

Reference:

APE 065 AAI.04 (3.5/3.4)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

X Actual Performance:

Classroom Simulator Plant X

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and when candidate locates procedure located on column 2B32, Unit 2 TB, near exit door leading to Diesel VI compressors, provide a copy of Handout 1.

Initial Conditions:

Units I nd 2 t I 1)0% nnwr whn lck dvlnns in th VI E

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

Task Standard:

The operator will start the G VI compressor per Enclosure 4 (Diesel VI Compressor Operation) of AP/1 /A15500/22.

Required Materials:

PPE (Hardhat, Safety Glasses, Hearing Protection, Safety Shoes etc.)

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Page 3 of ii Form ES-C-i Job Performance Measure Worksheet General

References:

API1/A15500122 (Loss of VI), Rev 33 Handouts:

Handout i: Enclosure 4 (Diesel VI Compressor Operation) of APIiIAI5500I22 (Loss of VI)

Time Critical Task:

NO Validation Time:

7 minutes 2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Page 4 of ii Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and when candidate locates procedure located on column 2B32, Unit 2 TB, near exit door leading to Diesel VI compressors, provide a copy of Handout 1.

START TIME:

Cue:

Upon arriving at the scene, the following conditions exist:

H VI Compressor is running.

G VI Compressor is NOT running.

REQUIRED STEPS ELEMENTS STANDARD S/U COMMENTS FOR UNSAT (Step 1) On running compressors, ensure associated compressor switches are in the following positions:

The operator observes Auto/Off-Reset the switches for H VI selector switch in AUTO.

Compressor.

HIGH/LOW selector switch, in HIGH.

STARTNVARM UP/RUN selector switch in RUN.

Cue:

As operator checks each switch:

AutolOff-Reset selector switch is in AUTO HIGH/LOW selector switch is in HIGH.

STARTIWARM UP/RUN switch is in RUN.

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

(Step 2.c) Ensure the START/WARM-UP/RUN selector switch is in RUN.

The operator ensures the START/WARM-UP/RU N selector switch is in RUN.

(AS FOUND = RUN)

Cue:

STARTIWARM-UP!RUN switch is in RUN.

Appendix C Page 5 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 2

(Note prior to Step 2)

The operator reads the Several G and H VI Note and proceeds.

Compressor gauges will not function until the associated ENGINE SWITCH is placed in the ON position in the following steps.

  • 3 (Step 2) IF G VI The operator places the Compressor is off, THEN Auto/Off-Reset selector perform the following:

switch in OFF-RESET.

(Step 2.a) Place the (AS FOUND = AUTO)

Auto/Off-Reset selector switch in OFF-RESET.

(Step 2.b) Ensure the The operator ensures the H IGH/LOW selector HI GH/LOW selector switch, is in HIGH.

switch, is in HIGH.

(AS FOUND = HIGH) 2014 Systems In-Plant JPM J NUREG 1021, Revision 9

(Step 2.d) Place ENGINE SWITCH in ON.

The operator places the ENGINE SWITCH in ON.

(Step 2.e) IF Diesel compressor fails to start within approximately 15 seconds, THEN perform the following:

(Step 2.e.1)) Place Engine switch in OFF.

The operator places the ENGINE SWITCH in OFF.

Appendix C Page 6 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 6

(Note prior to Step 2.d)

The operator reads the Engine will start after a 5 to Note and proceeds.

10 second time delay in next step.

7 Cue:

ENGINE SWITCH rotated clockwise to ON.

15 seconds have elapsed and the engine is NOT running.

Examiner Note: Allow the next two steps to be read before giving the 2 minutes have elapsed cue.

Cue:

Two minutes have elapsed.

The operator returns to Step 2.e.4.

Appendix C Page 7 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT (Step 2.e.2)) Do not attempt The operator waits 2 to start G VI compressor minutes.

until 2 minutes have elapsed.

10 (Step 2.e.3)) IF H VI The operator proceeds to compressor is off, THEN Step 3.

start H VI compressor PER step 3 while waiting to start G VI compressor.

1 1 (Step 2.e.4)) WHEN 2 The operator will proceed to minutes have elapsed, step 2.d.

THEN observe note prior to Step 2.d and RETURN TO Step 2.d.

Cue:

H VI Compressor is running.

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Page 8 of 11 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 12 (Step 2.d) Place ENGINE The operator reads the SWITCH in ON.

Note prior to Step 12.d and proceeds.

The operator places the ENGINE SWITCH in 13 (Step 3) IF H VI compressor The operator checks the is off, THEN perform the status of the H VI following...

Compressor.

Cue:

The H VI Compressor is running.

The operator determines that the H VI Compressor is running and proceeds to step 4.

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Page 9 of 1 1 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 14 (Step 4) WHEN time allows, The operator proceeds to THEN check running.12.

parameters PER OP/01A164501005 (Instrument Air system),.12 (Response to Auto/Emergency Start of G and/or H VI Compressor).

Cue:

Another operator will check the running parameters when time allows.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Page 10 of 1 1 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems In-Plant JPM J Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems In-Plant JPM J NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

Units 1 and 2 are at 100% power when a leak develops in the VI system.

AP111A15500122, Loss of VI, has been implemented up to step 4.c.

VI header pressure is 75 PSIG and going down.

INITIATING CUE:

Ensure Diesel VI compressors are running per Enclosure 4 (Diesel VI Compressor Operation) of API1IAI5500I22.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

NUREG 1021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet In-Plant JPM K 2014 Systems In-Plant JPM K (Rev_071814)

NUREG 1021, Revision 9

Appendix C Page 2 of 15 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Start up the Unit 1A Motor JPM No.:

2014 Systems In-Generator Set Plant JPM K K/A

Reference:

001 A2.iO (3.4/3.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

X Actual Performance:

Classroom Simulator Plant X

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout I.

Initii flnrfinn A Unit I strtun i n nrnnres with the niant in Mnrie 3 er Another operator has verified that Breaker 1 LXF-O1A, Control Rod Drive Set No.1A, is racked in to the CONNECT position.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

Task Standard:

The operator will start the iA M/G Set per Section 3.3 of Enclosure 4.1 of OPI1/A161501008.

Required Materials:

PPE (Hardhat, Safety Glasses, Hearing Protection, Safety Shoes etc.)

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 3 of 15 Form ES-C-i Job Performance Measure Worksheet General

References:

OP/11A161501008 (Rod Control), Rev 80 Handouts:

Handout 1: Enclosure 41 (M/G Startup) of OPI1IAJ61 50/008 (Rod Control), marked up so that steps 3.1 and 3.2 are complete; and such that Steps 3.3.2 and 33.5 are marked NA.

Time Critical Task:

NO Validation Time:

15 minutes 2014 Systems In-Plant JPM K NUREG 1021, Revision 9

(Note prior to Step 3.3.2) 0P111A16250/003 A (Restoring Slave Relays to Normal) requires closing and opening RTBs. MG sets may be running as long as Generator Circuit Breaker Control remains open and will NOT be closed during restoration of Slave Relays.

(Step 3.3.2) IF in Mode 5

The operator reads the Note and proceeds.

The operator recognizes that the plant is in Mode 3 (Initial Conditions), and that this Step does NOT apply.

Appendix C Page 4 of 15 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial ConditionslCue (Last Page of this JPM), and Handout 1.

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 1

(Note prior to Step 3.3.1)

The operator reads the Note Steps 3.3.1

- 3.3.5 may be and proceeds.

performed concurrently.

2 (Step 3.3.1) IF lB MG Set The operator recognizes that is NOT running the lB M/G set is operating (Initial Conditions), and that this Step does NOT apply.

3 2014 Systems In-Plant JPM K NUREG 1021, Revision 9

(Step 3.3.3.2) Ensure the following open:

Circuit Breaker Control on Motor for Generator No. 1 Circuit Breaker Control on Generator for Generator No. 1 The operator observes the 1A M/G Set Motor Breaker Control Switch.

Cue:

Green status light is LIT.

The operator observes the 1A M/G Set Generator Breaker Control Switch.

Cue:

Green status light is LIT.

(Step 3.3.3.3) Ensure 1 LXF O1A (Control Rod Drive MG Set No. 1A) racked to CONNECT per OP/O/AJ63501008 (Operation of Station Breakers).

The operator recognizes that another operator has verified that Breaker 1LXF-O1A is racked in to the CONNECT position (Initial Cue) and proceeds.

Appendix C Page 5 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 5

(Step 3.3.3) Perform the The operator observes the following:

1A M/G Set Generator (Step 3.3.3.1) Ensure tag Breaker Control Switch.

removed from Circuit Breaker Control on Cue:

Generator for Generator No. 1.

There are no tags present.

6 2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 6 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 8

(Step 3.3.4) IF iA MG Set The operator contacts to be started for Maintenance/Work Control.

maintenance, notify Maintenance that 1A MG Cue:

Set will be started.

Bobby Smith of Maintenance has been notified at current time and date.

(Step 3.3.5) IF startinglA The operator recognizes that MG Set with 1 B MG set the 1 B M/G set is operating NOT running (Initial Conditions), and that this Step does NOT apply.

Examiner Note: DO NOT allow operator to open I KS panel. A picture of the panel internals is provided on Page 14 of this JPM. Have the operator proceed to the panel, and then provide the picture as a reference. The picture shows the switch in the OPEN position.

10 (Note prior to Step 3.3.6)

The operator reads the Note 1 KS is located inside and proceeds.

Generator No. 2 panel, 4 ft from floor (access from top front panel).

1 1 (Step 3.3.6) Check open The operator observes the 1KS (3 pole grounding 1KS Switch (Picture).

switch).

Cue:

The I KS Switch is in the position as shown in the picture.

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 7 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 12 (Step 3.3.7) Push in to The operator pushes the 1A release from Pull Out MIG Set Generator Control position Circuit Breaker Switch inward.

Control on Generator for Generator No. 1.

(Inal Position = Pull-To-Cue:

The Control Switch is released from the PULL OUT position.

13 (Step 3.3.8) Push in to The operator pushes the 1A release from Pull Lamp Cut M/G Set Motor Control Switch Out position Circuit inward.

Breaker Control on Motor for Generator No. 1.

Cue:

The Control Switch is released from the PULL LAMP CUT OUT position.

14 (Step 3.3.9) Place The operator observes the Generator No. 1 Voltage 1A M/G Set Voltage Adjust Adjust potentiometer in 12 Potentiometer.

oclock position.

Cue:

The potentiometer is set at the 12 oclock position.

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 8 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT 15 (Step 3.3.10) Ensure The operator observes the Synchronize switch OFF.

Synchronize Switch position.

Cue:

The Synchronize Switch is in the OFF position.

  • 16 (Step 3.3.11) Close Motor The operator places the iA Circuit Breaker Control on M1G Set Motor Control Switch Generator No. 1.

to the ON position.

Cue:

The Switch is rotated to the closed position, the red light is lit and the sound of the motor increasing in speed is heard.

17 (Step 3.3.12) Allow 15 The operator waits 15 seconds to obtain full rated seconds.

speed.

Cue:

The sound of the motor speed is steady.

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 9 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 18 (Step 3.3.13) Depress and The operator depresses and HOLD Gen Field Flash holds the GEN FIELD FLASH pushbutton.

pushbutton.

Cue:

Generator Line Volts indication starts to rise.

  • 19 (Step 3.3.14) AFTER The operator observes Generator Line Volts Generator Line Volts meter.

stops rising (230

- 260 volts), release Gen Field Flash pushbutton.

Cue:

Generator Line Volts is stable at 245 volts.

The operator releases the GEN FIELD FLASH pushbutton.

20 (Note prior to Step 3.3.15)

The operator reads the Note The intent of the following and proceeds.

step is to check for dead spots on the voltage adjust potentiometer. An erratic voltage output (voltage jump high or low) is an unexpected response.

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 10 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS FOR UNSAT (Step 3.3.15) Cycle The operator rotates the Voltage Adjust Voltage Adjust Potentiometer potentiometer from 250 clockwise.

VAC to 270 VAC (to verify no erratic voltage CueS response).

Generator Line Volts is stable at 270 volts and stable 22 (Step 3.3.16) IF erratic The operator recognizes that voltage output observed the Generator Line Voltage is NOT erratic, and that this Step does NOT apply.

  • 23 (Step 3.3.17) Obtain 260 The operator rotates the volts on Generator Line Voltage Adjust Potentiometer Volts by rotating the M/G counter-clockwise.

Set Voltage Adjust potentiometer Cue Generator Line Volts is stable at 260 volts and stable.

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page ii of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT Examiner Note: DO NOT allow operator to open RTB Breaker Cubicle Doors during this JPM.

(Step 3.3.18) IF desired to close Generator No. 1 Generator Circuit Breaker Control for equipment check out, perform the following:

(Step 3.3.18.1) Check Reactor Trip Breakers open.

(Step 3.3.18.2) Ensure MG1A CiA Control Rod Drive MG Set Bkr) racked to CONNECT per OPIO/A/63501008 (Operation of Station Breakers).

The operator performs one of the following:

Opens (Simulates) the RTB Breaker Doors and observes status flags.

OR Calls the Control Room and requests the status of the Reactor Trip Breakers.

Cue:

If the RTB status flags are observed locally, state Cabinet doors are opened, status flags for both breakers are Green.

If the operator calls the Control Room, report that the Unit I OATC indicates that both Unit I RTBs are OPEN.

The operator recognizes that another operator has verified that Breaker 1LXF-O1A is racked in to the CONNECT position (Initial Cue) and proceeds.

24 2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 12 of 15 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS FOR UNSAT

  • 26 (Step 3.3.18.3) Close The operator places the 1A Generator No. 1 M/G Set Generator Control Generator Circuit Breaker Switch to the ON position.

Control.

Cue:

The Switch is rotated to the closed position, Red status light is LIT.

27 (Step 3.3.18.4) HOLD until The operator reports that the equipment checkout 1A M/G Set is ready for complete, THEN trip Maintenance.

Generator No. 1 Generator Circuit Breaker

Cue.

Control Another Operator will work with Maintenance to complete equipment checkout.

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 13 of 15 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Systems In-Plant JPM K Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Page 14 of 15 Form ES-C-i VERIFICATION OF COMPLETION 2014 Systems In-Plant JPM K NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET INITIAL CONDITIONS:

A Unit 1 startup is in progress with the plant in Mode 3.

All requirements for entering Mode 2 have been met.

The 1 B Rod Control MIG Set is running.

INITIATING CUE:

The CRS directs you to start the 1A M/G Set per OP/11A161501008 (Rod Control) Enclosure 4.1 (M/G Startup) for post maintenance inspection.

Another operator has verified that Breaker 1LXF-O1A, Control Rod Drive Set No.1A, is racked in to the CONNECT position.

NOTE: No plant equipment should be operated during the performance of this JPM. All actions must be SIMULATED.

NUREG 1021, Revision 9

ES-301 Administrative Topics Outline Form ES-301-1 (Rev_0731 14)

Facility:

McGuire Date of Examination:

8/2014 Examination Level:

RO Operating Test Number:

N14-1 Administrative Topic Type Code*

Describe activity to be performed (see Note) 2.1.25 (3.9)

Ability to interpret reference materials, such Conduct of Operations as graphs, curves, tables, etc.

M, R JPM:

Calculate Dilution Needed for a Specified Rod Change 2.1.4 (3.3)

Knowledge of individual licensed operator Conduct of Operations responsibilities related to shift staffing, such as medical requirements, no-solo N R operation, maintenance of active license

status, 10CFR55, etc.

JPM:

Determine License Status 2.2.12 (3.7)

Knowledge of Surveillance Procedures.

Equipment Control D, R JPM:

Perform NC Loop Operability Verification in Mode 4 2.3.1 1 (3.8)

Ability to control radiation releases Radiation Control M,R JPM:

Perform a Unit Vent Flow Calculation of a Containment Air Release NOTE:

All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (0) (S)imulator, (0) or Class(R)oom (4)

(D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes) (0)

(N)ew or (M)odified from bank (> 1) (3)

(P)revious 2 exams ( 1; randomly selected) (0)

NUREG-1 021, Revision 9

ES-301 Administrative Topics Outline Form ES-301-1 (Rev_0731 14)

RO Admin JPM Summary Ala This is a modified Bank JPM.

The operator will be given a set of initial conditions and told that it is desired to insert the Bank D Control Rods about 45 steps.

The Operator will be to determine the amount of reactor makeup water needed to obtain the desired Control Rod Height.

The operator is expected to calculate a dilution of 2390+/-150 gallons is required to make the specified rod height change.

Al b This is a New JPM. The operator will be told that they are a Licensed Reactor Operator who is currently not routinely standing watch in the Control Room, that their supervisor has directed them to stand watch as needed to maintain their license active, and will be provided with a recent work history.

The operator will be directed to complete NSD Form 512-1 to track the maintenance of their license for this quarter, and to identify additional requirements, if any, that must be met this quarter to maintain their license active. The operator will be expected to record the completion of the qualifying watches, on Form 512-1 in accordance with the attached KEY, and identify that 2 additional 12-hour shifts must be stood as either the Ui RO, Ui BOP, U2 RO or U2 BOP by 9/30/14 to maintain the license active.

A2 This is a Bank JPM.

The operator will be told that the Plant is in Mode 5 with NCS Temperature at 188°F and stable, and will be provided with current plant data regarding the decay heat removal systems.

The operator will be directed to perform Enclosure 13.5 (NC Loop Operability Verification in Mode 4) of PTI1/A14600/003 C (Weekly Surveillance Items),

in preparation to transition to Mode 4.

The operator will be expected to complete Enclosure 13.5 in accordance with the Attached KEY. This is the same JPM as the SRO Exam.

A3 This is a modified Bank JPM.

The operator will be told that GWR Package # 2014013 for Unit 1 Containment Air Release is currently in use to conduct a series of Containment air releases, and that during the first release, conducted using Enclosure 4.2 (Air Release Mode With VQ Flow Monitor Operable) of OP/1/A/6450/017 (Containment Air Addition and Release), the Unit 1 VQ Monitor became inoperable. The operator will be told that the crew stopped the release and continued the air release using Enclosure 4.3 (Air Release Mode with VQ Flow Monitor Inoperable) of OP/1/A16450/017 (Containment Air Addition and Release), and that three previous releases have been made; including the one which was made with the Unit 1 VQ Flow Monitor in operation.

Finally, the operator will be provided with the pertinent data for the current (

4 th) release, and then be directed to calculate the volume released for the current release and to determine the total volume released from the Containment during all releases.

The operator will be expected to calculate the volume of air released from the Containment during the final release, and determine the total volume of air released in the series of four releases.

This is the same JPM as the SRO Exam.

NUREG-1 021, Revision 9

Appendix C Job Performance Measure Form ES-C-i Worksheet JPMAIaRO 2014 Admin

- JPM Ala RO (REV_071414)

NUREG 1021, Revision 9

Appendix C Page 2 of 8 Form ES-C-i Job Performance Measure Worksheet Facility:

McGuire Task No.:

Task

Title:

Calculate Dilution Needed for a JPM No.:

2014 Admin

- JPM Ala Specified Rod Change RO K/A

Reference:

2.1.25 (3.9)

Examinee:

NRC Examiner:

Facility Evaluator:

Date:

Method of testing:

Simulated Performance:

Actual Performance:

X Classroom X

Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Provide Candidate with Initial ConditionslCue (Last Page of this JPM).

Initial Conditions:

Unit #1 Reactor Power is at 100%, Steady State, for several days.

The QAC is not available to determine amount of dilution.

Core burnup is 260 EFPD.

NC Boron Concentration = 688 PPM.

Present Control Rods Bank D at 220 steps.

Desired Rod Height is Control Rods Bank D at 175 steps Initiating Cue:

The CRS has directed you to determine the amount of reactor makeup water needed to obtain the desired Control Rod Height Task Standard:

The operator will calculate a dilution of 2390+/-150 gallons is required to make the specified rod height change.

Required Materials:

Calculator General

References:

QP/1/A16150/009 (Boron Concentration Control), Rev 124 QP/l/A16l00/022 (Unit 1 Data Book) Cycle 21, Rev 481 2014 Admin

- JPM Ala RO NUREG 1021, Revision 9

AppendlxC Page3of8 FormES-C-1 Job Performance Measure Worksheet Handouts:

None Time Critical Tasic NO ValIdation lime:

45 mInutes 2Ol4Mmln-JPMAIaRO NUREG 1021, RevIsion 9

Appendix C Page 4 of 8 Form ES-C-i PERFORMANCE INFORMATION (Denote Critical Steps with an asterisk*)

Provide Candidate with Initial Conditions/Cue (Last Page of this JPM).

START TIME:

STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 1 (OPI1/A16150/009, Step Initial inserted 3.4) Determine amount of reactivity worth =

reactor makeup water needed to obtain desired Wpcm boron concentration using McGuire Data Book, OAC, Reactor Group Guidance, or plant parameters (T-Ave, Steam Pressure, Xenon worth, etc.). (R.M.)

Operator determines 220 steps integral rod worth using the 251-350 EFPD column of OP/i/A16i 00/22,.3, Table 6.3.3, IRW in Overlap, HFP, Equilibrium Xe.

  • 2 Operator determines 175 Desired Rod height steps integral rod worth inserted reactivity using the 251-350 EFPD worth =

column of OP/i/A/6i00/22, 161 pcm.3, Table 6.3.3, IRW in Overlap, HFP, Equilibrium Xe.

2014 Admin

- JPM Al a RO NUREG 1021, Revision 9

Appendix C Page 5 of 8 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 3 Operator determines the Change in reactivity to change in reactivity be compensated due to required for the rod rod insertion =

insertion 161 pcm

-9 pcm 152 pcm

  • 4 Using OP/i/A16100/22, Operator determines the.3, Graph Differential Boron Worth 6.11 Differential Boron from the graph to be Worth (HFP, ARO, Eq

- (6.49-6.50)

Xe, Eq Sm, Unit 1 Cycle pcmlppm

22) determines the Differential Boron Worth for present conditions (250-300 EFPD) 5 Using the Differential Operator determines the Boron Worth and the change in Boron Change in reactivity, Concentration to be =

determines the change in 152 i - 6.49 to 6.50 Boron Concentration pcm/ppm

=

-23.42 to 23.38 rn 6

Operator determines Change in Boron =

Boron Concentration 688 23.42 to 23.38 required ppm

= 664.58 to 664.62 ppm 2014 Admin

- JPM Al a RO NUREG 1021, Revision 9

Appendix C Page 6 of 8 Form ES-C-i PERFORMANCE INFORMATION STEPS ELEMENTS STANDARD S/U COMMENTS REQUIRED FOR UNSAT

  • 7 Using OP111A16100122, Using Present Boron.3 Section 5.1 Concentration 688 ppm Boron and Dilution and the Desired Boron Tables, determines the Concentration of 665 Reactor Makeup Water ppm, determines from addition Table that change from 690-665 ppm will require the addition of 2489 gallons of reactor makeup water.

OR Calculation:

67388 x Ln(688/665) =

2291 gallons.

Total Makeup Water to add =2390+150 gallons (2240-2540 gallons).

Terminating Cue:

Evaluation on this JPM is complete.

STOP TIME:

2014 Admin

- JPM Ala RO NUREG 1021, Revision 9

Appendix C Page 7 of 8 Form ES-C-i VERIFICATION OF COMPLETION Job Performance Measure No.:

2014 Admin

- JPM Ala RO Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Result:

SAT UNSAT Examiners Signature:

Date:

2014 Admin

- JPM Ala RO NUREG 1021, Revision 9

Appendix C Form ES-C-i JPM CUE SHEET Initial Conditions:

Unit #1 Reactor Power is at i 00%, Steady State, for several days.

The QAC is not available to determine amount of dilution.

Core burnup is 260 EFPD.

NC Boron Concentration = 688 PPM.

Present Control Rods Bank D at 220 steps.

Desired Rod Height is Control Rods Bank D at i 75 steps.

INITIATING CUE:

The CRS has directed you to determine the amount of reactor makeup water needed to obtain the desired Control Rod Height.

NUREG 1021, Revision 9