2014 DCPP REMP Analysis Results Appendix C 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Cobalt-60 2.36E-01 2.13E+OO 1.23E+OO pCi/L 7C2 Rattlesnake Canyon(351324002) - SW 19-Jun-14 Cobalt-60
-6.82E-02 2.28E+OO 1.38E+OO pCi/L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Cobalt-60 5.06E-01 1.96E+OO 1.17E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Cobalt-60 3.85E-01 2.61 E+OO 1.79E+OO pCi/L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Cobalt-60 4.39E-02 2.35E+OO 1.41E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Cobalt-60 1.01 E-02 1.98E+OO 1.16E+OO pCi/L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Cobalt-60 5.79E-01 1.95E+OO 1.14E+OO pCi/L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Cobalt-60 2.92E-01 2.27E+OO 1.35E+OO pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 lodine-131 3.75E+OO 5.25E+OO 3.43E+OO pCi/L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 lodine-131 7.92E-01 3.48E+OO 2.03E+OO pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 lodine-131
-3.74E-01 4.27E+OO 2.63E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 lodine-131
-5.65E-01 3.10E+OO 1.84E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 lodine-131
-6.90E-03 3.36E+OO 2.26E+OO pCi!L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 lodine-131 1.56E+OO 3.87E+OO 2.40E+OO pCi!L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 lodine-131
-4.01 E-01 4.03E+OO 2.42E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 lodine-131
-3.79E-01 4.24E+OO 2.58E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 lodine-131 2.07E+OO 5.03E+OO 3.10E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 lodine-131 1.90E-01 3.74E+OO 2.21 E+OO pCi/L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 lodine-131 7.64E-01 3.30E+OO 1.95E+OO pCi!L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 lodine-131 7.20E-01 4.30E+OO 2.62E+OO pCi!L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Iron-55
-3.83E+01 7.73E+01 5.27E+01 pCi/L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Iron-55
-4.97E+01 9.03E+01 6.39E+01 pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Iron-55
-1.33E+01 8.71 E+01 6.38E+01 pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Iron-55
-8.84E-01 9.89E+01 6.86E+01 pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Iron-55 6.72E+OO 7.57E+01 5.43E+01 pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Iron-55
-3.25E+01 6.08E+01 3.95E+01 pCi!L 7C2 Rattlesnake Canyon(3531 00003) - SW 15-Jul-14 Iron-55
-2.13E+01 1.10E+02 7.97E+01 pCi!L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Iron-55
-1.74E+01 9.66E+01 7.02E+01 pCi/L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Iron-55
-3.05E+01 7.78E+01 5.04E+01 pCi!L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Iron-55 5.28E+01 7.77E+01 5.91 E+01 pCi/L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Iron-55 5.32E+OO 7.97E+01 5.55E+01 pCi/L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Iron-55 1.94E+01 4.86E+01 3.41 E+01 pCi/L 7C2 Rattlesnake Canyon(342317003) - SW 27-Jan-14 Iron-59 2.56E-01 5.57E+OO 3.26E+OO pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Iron-59
-4.39E-01 3.85E+OO 3.16E+OO pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Iron-59 1.54E-01 4.52E+OO 2.68E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Iron-59
-1.17E+OO 3.30E+OO 2.42E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Iron-59 6.64E-01 4.38E+OO 2.61 E+OO pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Iron-59
-1.82E+OO 4.45E+OO 3.71E+OO pCi/L 7C2 Rattlesnake Canyon(3531 00003) - SW 15-Jul-14 Iron-59 1.12E+OO 4.11E+OO 2.45E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Iron-59
-1.27E+OO 4.83E+OO 3.64E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Iron-59
-6.80E-02 4.90E+OO 2.90E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Iron-59
-3.37E-01 4.14E+OO 2.53E+OO pCi/L 7C2 Rattlesnake Canyon(360977001)- SW 5-Nov-14 Iron-59
-3.60E-02 3.64E+OO 2.22E+OO pCi/L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Iron-59
-1.44E+OO 4.78E+OO 3.02E+OO pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Lanthanum-140
-3.09E+OO 4.45E+OO 3.27E+OO pCi/L Page 28 of 92
2014 DCPP REMP Analysis Results Appendix C 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Lanthanum-140 5.25E-01 2.85E+OO 1.90E+OO pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Lanthanum-140
-1.64E+OO 3.34E+OO 2.26E+OO pCi!L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Lanthanum-140 2.51E+OO 2.85E+OO 2.40E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Lanthanum-140
-8.09E-01 3.12E+OO 2.14E+OO pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Lanthanum-140
-1.62E+OO 2.86E+OO 2.36E+OO pCi/L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Lanthanum-140 7.11E-01 3.29E+OO 1.90E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Lanthanum-140
-4.56E-01 3.69E+OO 2.21 E+OO pCi/L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Lanthanum-140 2.36E-01 4.16E+OO 2.42E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Lanthanum-140
-2.18E+OO 3.01 E+OO 2.26E+OO pCi!L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Lanthanum-140 1.51 E-02 2.92E+OO 1.75E+OO pCi/L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Lanthanum-140
-3.71 E-01 3.45E+OO 2.45E+OO pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Manganese-54 2.42E-01 2.66E+OO 2.20E+OO pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Manganese-54
-1.03E+OO 1.62E+OO 1.29E+OO pCi/L 7C2 Rattlesnake Canyon(345420003)- SW 24-Mar-14 Manganese-54
-5.88E-01 2.04E+OO 1.25E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Manganese-54
-1.37E-01 1.70E+OO 1.04E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Manganese-54
-1.12E-01 1.84E+OO 1.10E+OO pCi!L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Manganese-54 9.24E-01 2.17E+OO 1.29E+OO pCi/L 7C2 Rattlesnake Canyon(353100003) ~ SW 15-Jul-14 Manganese-54 6.08E-01 1.83E+OO 1.08E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Manganese-54 4.73E-01 2.19E+OO 1.31 E+OO pCi/L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Manganese-54 3.13E-01 2.16E+OO 1.30E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Manganese-54 2.44E-01 1.79E+OO 1.05E+OO pCi!L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Manganese-54 4.40E-01 1.71 E+OO 1.01 E+OO pCi/L 7C2 Rattlesnake Canyon(363121 002)- SW 8-Dec-14 Manganese-54 4.70E-01 2.09E+OO 1.21 E+OO pCi/L 7C2 Rattlesnake Canyon(342317003) - SW 27-Jan-14 Nickel-63 8.16E+OO 3.54E+01 2.15E+01 pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Nickel-63 1.44E+01 2.98E+01 1.86E+01 pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Nickel-63 3.54E+OO 3.42E+01 2.05E+01 pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Nickel-63 1.07E+OO 3.29E+01 1.96E+01 pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Nickel-63 2.1 OE+01 2.92E+01 1.87E+01 pCi!L 7C2 Rattlesnake Canyon(351324002) - SW 1 9-Jun-14 Nickel-63
-9.93E+OO 2.97E+01 1.72E+01 pCi/L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Nickel-63 2.46E+01 3.16E+01 2.04E+01 pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Nickel-63 3.74E+OO 3.41 E+01 2.05E+01 pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Nickel-63
-1.33E+01 3.87E+01 2.25E+01 pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Nickel-63
-1.32E+OO 2.96E+01 1.76E+01 pCi/L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Nickel-63 9.61E+OO 3.42E+01 2.07E+01 pCi!L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Nickel-63 9.11 E+OO 2.79E+01 1.71E+01 pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Niobium-95 2.45E-01 2.63E+OO 1.56E+OO pCi/L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Niobium-95 6.52E-02 1.88E+OO 1.09E+OO pCi!L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Niobium-95 3.41 E-01 2.20E+OO 1.32E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Niobium-95
-4.51 E-01 1.74E+OO 1.09E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Niobium-95
-5.59E-01 1.76E+OO 1.27E+OO pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Niobium-95 1.10E+OO 2.12E+OO 1.32E+OO pCi!L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Niobium-95 1.20E+OO 1.97E+OO 1.22E+OO pCi/L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Niobium-95 8.66E-01 2.32E+OO 1.40E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Niobium-95
-3.36E-01 2.20E+OO 1.36E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Niobium-95 5.34E-01 2.07E+OO 1.21 E+OO pCi/L Page 29 of 92
2014 DCPP REMP Analysis Results Appendix C 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Niobium-95 1.61 E+OO 1.63E+OO 1.62E+OO pCi!L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Niobium-95 1.20E+OO 2.12E+OO 1.61 E+OO pCi!L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Potassium-40 3.29E+02 2.49E+01 5.42E+01 pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Potassium-40 3.44E+02 1.67E+01 4.64E+01 pCi!L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Potassium-40 3.54E+02 2.14E+01 5.16E+01 pCi!L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Potassium-40 3.65E+02 1.65E+01 4.89E+01 pCi!L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Potassium-40 3.20E+02 2.04E+01 5.26E+01 pCi!L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Potassium-40 3.38E+02 2.18E+01 4.88E+01 pCi/L 7C2 Rattlesnake Canyon(3531 00003) - SW 15-Jul-14 Potassium-40 3.40E+02 1.88E+01 4.57E+01 pCi!L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Potassium-40 3.90E+02 2.08E+01 5.21 E+01 pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Potassium-40 3.57E+02 2.18E+01 5.20E+01 pCi!L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Potassium-40 3.42E+02 2.04E+01 5.19E+01 pCi/L 7C2 Rattlesnake Canyon(360977001)- SW 5-Nov-14 Potassium-40 3.61E+02 1.61 E+01 4.49E+01 pCi/L 7C2 Rattlesnake Canyon(363121 002)- SW 8-Dec-14 Potassium-40 3.32E+02 1.94E+01 5.07E+01 pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Total Strontium
-2.27E+OO 2.88E+OO 1.61 E+OO pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Total Strontium
-6.30E-01 5.11 E+OO 3.02E+OO pCi!L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Total Strontium
-3.23E-01 3.51 E+OO 2.08E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Total Strontium
-4.14E+OO 3.07E+OO 1.68E+OO pCi!L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Total Strontium 8.45E-01 2.84E+OO 1.74E+OO pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Total Strontium 1.96E+OO 2.29E+OO 1.50E+OO pCi!L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Total Strontium 1.33E+OO 2.26E+OO 1.43E+OO pCi!L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Total Strontium
-2.38E+OO 2.22E+OO 1.22E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Total Strontium
-2.68E+OO 3.29E+OO 1.86E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Total Strontium 5.76E-01 3.18E+OO 1.92E+OO pCi!L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Total Strontium 6.86E-01 2.94E+OO 1.78E+OO pCi!L 7C2 Rattlesnake Canyon(363121 002)- SW 8-Dec-14 Total Strontium
-5.1 OE-01 4.18E+OO 2.47E+OO pCi!L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Tritium 1.60E+01 2.41 E+02 1.45E+02 pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Tritium
-8.47E+01 2.68E+02 1.56E+02 pCi!L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Tritium 1.21 E+02 2.41 E+02 1.52E+02 pCi!L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Tritium 1.87E+02 2.64E+02 1.70E+02 pCi!L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Tritium
-1.74E+01 2.27E+02 1.34E+02 pCi!L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Tritium 9.08E+01 2.53E+02 1.56E+02 pCi/L 7C2 Rattlesnake Canyon(3531 00003) - SW 15-Jul-14 Tritium
-8.95E+OO 2.55E+02 1.51 E+02 pCi!L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Tritium 4.44E+01 2.26E+02 1.37E+02 pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Tritium
-9.17E+01 2.69E+02 1.56E+02 pCi!L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Tritium 1.66E+02 2.44E+02 1.58E+02 pCi/L 7C2 Rattlesnake Canyon(360977001)- SW 5-Nov-14 Tritium 2.12E+02 2.60E+02 1.70E+02 pCi/L 7C2 Rattlesnake Canyon(363121002)- SW 8-Dec-14 Tritium
-4.08E+01 2.70E+02 1.59E+02 pCi/L 7C2 Rattlesnake Canyon(342317003)- SW 27-Jan-14 Zinc-65
-2.25E+OO 5.96E+OO 3.84E+OO pCi/L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Zinc-65 2.28E+OO 3.80E+OO 2.61E+OO pCi/L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Zinc-65
-1.67E+OO 4.49E+OO 2.90E+OO pCi/L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-14 Zinc-65 2.80E-01 3.49E+OO 2.36E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Zinc-65 7.20E-01 4.52E+OO 2.70E+OO pCi/L 7C2 Rattlesnake Canyon(351324002)- SW 19-Jun-14 Zinc-65
-5.13E-01 4.82E+OO 2.92E+OO pCi!L 7C2 Rattlesnake Canyon(3531 00003)- SW 15-Jul-14 Zinc-65
-3.34E+OO 3.44E+OO 2.81E+OO pCi/L ---
Page 30 of 92
2014 DCPP REMP Analysis Results Appendix C 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Zinc-65 3.91 E-01 4.52E+OO 3.08E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Zinc-65 8.74E-01 5.26E+OO 3.09E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Zinc-65
-2.53E+OO 4.49E+OO 3.93E+OO pCi!L I
7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Zinc-65
-6.54E-01 4.05E+OO 2.53E+OO pCi!L 7C2 Rattlesnake Canyon(363121 002)- SW 8-Dec-14 Zinc-65
-1.05E+OO 4.30E+OO 3.15E+OO pCi!L 7C2 Rattlesnake Canyon(342317003) - SW 27-Jan-14 Zirconium-95
-9.80E-01 4.57E+OO 3.31 E+OO pCi!L 7C2 Rattlesnake Canyon(343846003) - SW 24-Feb-14 Zirconium-95 1.16E+OO 3.33E+OO 1.95E+OO pCi!L 7C2 Rattlesnake Canyon(345420003) - SW 24-Mar-14 Zirconium-95
-6.57E-02 3.98E+OO 2.42E+OO pCi!L 7C2 Rattlesnake Canyon(346578003) - SW 7-Apr-:14 Zirconium-95
-1.50E+OO 2.91 E+OO 1.96E+OO pCi/L 7C2 Rattlesnake Canyon(348878002) - SW 12-May-14 Zirconium-95 5.12E-01 3.71E+OO 2.47E+OO pCi/L 7C2 Rattlesnake Canyon(351324002) - SW 19-Jun-14 Zirconium-95
-3.53E-01 3.61 E+OO 2.22E+OO pCi/L 7C2 Rattlesnake Canyon(3531 00003) - SW 15-Jul-14 Zirconium-95
-2.01 E+OO 3.00E+OO 2.10E+OO pCi!L 7C2 Rattlesnake Canyon(354812002)- SW 11-Aug-14 Zirconium-95
-3.40E-01 4.08E+OO 2.48E+OO pCi!L 7C2 Rattlesnake Canyon(356752001)- SW 8-Sep-14 Zirconium-95
-1.65E+OO 3.77E+OO 2.50E+OO pCi/L 7C2 Rattlesnake Canyon(359457002) - SW 15-0ct-14 Zirconium-95
-9.84E-01 3.38E+OO 2.10E+OO pCi!L 7C2 Rattlesnake Canyon(360977001) - SW 5-Nov-14 Zirconium-95 2.96E-02 3.12E+OO 1.84E+OO pCi/L 7C2 Rattlesnake Canyon(363121 002)- SW 8-Dec-14 Zirconium-95 6.58E-01 3.73E+OO 2.46E+OO pCi!L 7D1 Avila Gate-Air Charcoal Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 7D1 Avila Gate(340937009)- AC 3-Jan-14 lodine-131 1.33E-03 1.13E-02 6.60E-03 pCi/m3 7D1 Avila Gate(341469009)- AC 11-Jan-14 lodine-131 2.64E-03 1.39E-02 7.86E-03 pCilm3 7D1 Avila Gate(341857009)- AC 18-Jan-14 lodine-131 3.56E-04 9.43E-03 5.65E-03 pCilm3 7D1 Avila Gate(342138009)- AC 25-Jan-14 lodine-131
-5.35E-03 1.68E-02 1.08E-02 pCilm3 7D1 Avila Gate(342582009)- AC 1-Feb-14 lodine-131
-5.02E-03 9.31 E-03 6.87E-03 pCi!m3 7D1 Avila Gate(343015009)- AC 8-Feb-14 lodine-131
-1.00E-03 1.25E-02 7.50E-03 pCi/m3 7D1 Avila Gate(343355009)- AC 15-Feb-14 lodine-131
-2.12E-03 8.58E-03 5.61 E-03 pCi/m3 7D1 Avila Gate(343769009)- AC 22-Feb-14 lodine-131
-1.06E-03 1.05E-02 6.33E-03 pCi/m3 7D1 Avila Gate(344077009)- AC 1-Mar-14 lodine-131 3.20E-03 1.25E-02 7.18E-03 pCi!m3 7D1 Avila Gate(344522009)- AC 8-Mar-14 lodine-131 3.62E-04 8.69E-03 5.20E-03 pCi/m3 7D1 Avila Gate(344947008)- AC 15-Mar-14 lodine-131
-2.04E-03 9.66E-03 6.26E-03 pCi!m3 7D1 Avila Gate(345381009)- AC 22-Mar-14 lodine-131 5.39E-04 1.11 E-02 6.58E-03 pCi/m3 7D1 Avila Gate(345737009)- AC 29-Mar-14 lodine-131 3.62E-03 9.87E-03 5.70E-03 pCilm3 7D1 Avila Gate(346448009)- AC 5-Apr-14 lodine-131 3.78E-04 1.11 E-02 6.59E-03 pCilm3 7D1 Avila Gate(346883009)- AC 12-Apr-14 lodine-131
-4.35E-03 9.80E-03 6.85E-03 pCilm3 7D1 Avila Gate(347387006)- AC 19-Apr-14 lodine-131
-3.54E-03 1.01 E-02 6.61 E-03 pCilm3 7D1 Avila Gate(347862009)- AC 26-Apr-14 lodine-131
-1.57E-04 1.01 E-02 6.16E-03 pCi!m3 7D1 Avila Gate(348342009)- AC 3-May-14 lodine-131
-1.73E-03 9.27E-03 5.90E-03 pCi/m3 7D1 Avila Gate(348779009)- AC 10-May-14 lodine-131
-6.27E-03 8.93E-03 6.54E-03 pCi!m3 7D1 Avila Gate(349262009)- AC 17-May-14 lodine-131
-4.70E-03 1.23E-02 8.40E-03 pCilm3 7D1 Avila Gate(349563009)- AC 24-May-14 lodine-131 2.05E-03 1.09E-02 6.14E-03 pCilm3 7D1 Avila Gate(350052009)- AC 31-May-14 lodine-131 8.54E-04 9.56E-03 5.66E-03 pCi!m3 7D1 Avila Gate(350455009)- AC 7-Jun-14 lodine-131 6.36E-03 1.27E-02 7.76E-03 pCilm3 7D1 Avila Gate(350986009)- AC 14-Jun-14 lodine-131 3.40E-03 9.46E-03 5.96E-03 pCilm3 701 Avila Gate(351433009)- AC 21-Jun-14 lodine-131 2.35E-03 1.23E-02 7.76E-03 pCilm3 Page 31 of 92
2014 DCPP REMP Analysis Results Appendix C 701 Avila Gate(351789009)- AC 28-Jun-14 lodine-131 3.27E-03 2.25E-02 1.31E-02 pCi/m3 701 Avila Gate(352368009)- AC 5-Jul-14 lodine-131 3.00E-04 9.52E-03 5.57E-03 pCilm3 701 Avila Gate(352849015)- AC 12-Jul-14 lodine-131
-2.27E-03 7.97E-03 5.03E-03 pCilm3 701 Avila Gate(353399009)- AC 19-Jul-14 lodine-131 3.16E-03 1.03E-02 5.80E-03 pCilm3 701 Avila Gate(353786009)- AC 26-Jul-14 lodine-131
-4.34E-03 8.28E-03 6.01 E-03 pCilm3 701 Avila Gate(354272009)- AC 2-Aug-14 lodine-131 1.07E-03 8.82E-03 5.02E-03 pCilm3 701 Avila Gate(354689009)- AC 9-Aug-14 lodine-131 1.03E-03 1.36E-02 7.85E-03 pCi/m3 701 Avila Gate(355193009)- AC 16-Aug-14 lodine-131 9.59E-04 1.17E-02 6.96E-03 pCilm3 701 Avila Gate(355650009)- AC 23-Aug-14 lodine-131
-6.84E-05 1.38E-02 8.26E-03 pCilm3 701 Avila Gate(356013009)- AC 30-Aug-14 lodine-131
-8.45E-04 1.64E-02 9.96E-03 pCilm3 701 Avila Gate(356629009)- AC 6-Sep-14 lodine-131 3.61 E-03 1.64E-02 9.26E-03 pCilm3 701 Avila Gate(357003009)- AC 13-Sep-14 lodine-131 2.24E-03 9.22E-03 5.20E-03 pCilm3 701 Avila Gate(357441009)- AC 20-Sep-14 lodine-131 5.66E-03 1.03E-02 5.84E-03 pCilm3 701 Avila Gate(357901 009)- AC 27-Sep-14 lodine-131 2.12E-03 1.29E-02 8.48E-03 pCilm3 701 Avila Gate(358659009)- AC 4-0ct-14 lodine-131
-2.37E-03 9.61 E-03 6.25E-03 pCilm3 701 Avila Gate(359172009)- AC 11-0ct-14 lodine-131 3.23E-03 1.20E-02 6.93E-03 pCi/m3 701 Avila Gate(359686009)- AC 18-0ct-14 lodine-131 7.76E-03 1.17E-02 6.76E-03 pCi/m3 701 Avila Gate(360173009)- AC 25-0ct-14 lodine-131
-1.27E-03 1.50E-02 9.29E-03 pCilm3 701 Avila Gate(360704009)- AC 1-Nov-14 lodine-131
-5.97E-03 8.13E-03 6.29E-03 pCilm3 701 Avila Gate(361184009)- AC 8-Nov-14 lodine-131 3.35E-03 9.35E-03 5.17E-03 pCilm3 701 Avila Gate(361687009)- AC 15-Nov-14 lodine-131 7.15E-04 1.06E-02 6.25E-03 pCilm3 701 Avila Gate(362077009)- AC 22-Nov-14 lodine-131 8.26E-03 1.86E-02 1.06E-02 pCilm3 701 Avila Gate(362293009)- AC 28-Nov-14 lodine-131
-9.01 E-04 1.88E-02 1.14E-02 pCilm3 701 Avila Gate(362893009)- AC 6-Dec-14 lodine-131 2.22E-03 1.11 E-02 6.39E-03 pCi/m3 701 Avila Gate(363523009)- AC 13-Dec-14 lodine-131
-1.03E-03 1.53E-02 9.30E-03 pCi/m3 701 Avila Gate(363779009)- AC 20-Dec-14 lodine-131
-4.85E-04 1.70E-02 1.01 E-02 pCi/m3 701 Avila Gate(363946009)- AC 26-Dec-14 lodine-131
-8.01 E-03 8.27E-03 7.09E-03 pCilm3 701 Avila Gate-Air Particulate Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 701 Avila Gate(340937002)- AP 3-Jan-14 BETA 1.06E-01 1.03E-03 1.05E-02 pCilm3 701 Avila Gate(341469002)- AP 11-Jan-14 BETA 4.57E-02 1.33E-03 1.05E-02 pCi/m3 701 Avila Gate(341857002)- AP 18-Jan-14 BETA 7.79E-02 1.24E-03 1.20E-02 pCilm3 701 Avila Gate(342138002)- AP 25-Jan-14 BETA 9.73E-02 1.34E-03 1.34E-02 pCilm3 701 Avila Gate(342582002)- AP 1-Feb-14 BETA 1.46E-02 1.32E-03 1.07E-02 pCi/m3 701 Avila Gate(343015002)- AP 8-Feb-14 BETA 2.57E-02 1.35E-03 1.01 E-02 pCilm3 701 Avila Gate(343355002)- AP 15-Feb-14 BETA 2.22E-02 1.38E-03 9.90E-03 pCilm3 701 Avila Gate(343769002)- AP 22-Feb-14 BETA 3.17E-02 1.32E-03 1.06E-02 pCilm3 701 Avila Gate(344077002)- AP 1-Mar-14 BETA 1.42E-02 1.64E-03 1.34E-02 pCilm3 701 Avila Gate(344522002)- AP 8-Mar-14 BETA 2.49E-02 1.25E-03 1.16E-02 pCilm3 701 Avila Gate(344947002)- AP 15-Mar-14 BETA 2.95E-02 1.35E-03 1.05E-02 pCilm3 701 Avila Gate(345381002)- AP 22-Mar-14 BETA 2.97E-02 1.36E-03 1.27E-02 pCi/m3 701 Avila Gate(345737002)- AP 29-Mar-14 BETA 1.25E-02 1.23E-03 9.14E-03 pCilm3 701 Avila Gate(346448002)- AP 5-Apr-14 BETA 2.60E-02 1.32E-03 9.39E-03 pCilm3 701 Avila Gate(346883002)- AP 12-Apr-14 BETA 2.92E-02 1.28E-03 9.89E-03 pCi/m3 Page 32 of 92
2014 DCPP REMP Analysis Results Appendix C 701 Avila Gate(347387002)- AP 19-Apr-14 BETA 3.1 OE-02 1.36E-03 9.33E-03 pCi!m3 701 Avila Gate(347862002)- AP 26-Apr-14 BETA 2.40E-02 1.45E-03 9.92E-03 pCi!m3 701 Avila Gate(348342002)- AP 3-May-14 BETA 2.99E-02 1.41 E-03 1.05E-02 pCi/m3 701 Avila Gate(348779002)- AP 10-May-14 BETA 1.19E-02 1.49E-03 9.05E-03 pCi!m3 701 Avila Gate(349262002)- AP 17-May-14 BETA 3.03E-02 1.46E-03 1.12E-02 pCi!m3 701 Avila Gate(349563002)- AP 24-May-14 BETA 9.73E-03 1.28E-03 8.33E-03 pCi/m3 701 Avila Gate(350052002)- AP 31-May-14 BETA 1.92E-02 1.27E-03 1.09E-02 pCi!m3 701 Avila Gate(350455002)- AP 7-Jun-14 BETA 1.08E-02 1.80E-03 1.26E-02 pCi!m3 701 Avila Gate(350986002)- AP 14-Jun-14 BETA 1.90E-02 1.18E-03 8.79E-03 pCi!m3 701 Avila Gate(351433002)- AP 21-Jun-14 BETA 1.40E-02 1.37E-03 9.56E-03 pCi!m3 701 Avila Gate(351789002)- AP 28-Jun-14 BETA 7.30E-03 1.44E-03 1.10E-02 pCi!m3 701 Avila Gate(352368002)- AP 5-Jul-14 BETA 1.16E-02 1.42E-03 8.64E-03 pCi/m3 701 Avila Gate(352849002)- AP 12-Jul-14 BETA 1.14E-02 1.29E-03 1.09E-02 pCi/m3 701 Avila Gate(353399002)- AP 19-Jul-14 BETA 2.29E-02 1.29E-03 1.13E-02 pCi!m3 701 Avila Gate(353786002)- AP 26-Jul-14 BETA 1.80E-02 1.26E-03 1.11 E-02 pCi/m3 701 Avila Gate(354272002)- AP 2-Aug-14 BETA 1.87E-02 1.39E-03 9.82E-03 pCi/m3 701 Avila Gate(354689002)- AP 9-Aug-14 BETA 1.91 E-02 1.34E-03 1.02E-02 pCi!m3 701 Avila Gate(355193002)- AP 16-Aug-14 BETA 1.66E-02 1.38E-03 9.20E-03 pCi!m3 701 Avila Gate(355650002)- AP 23-Aug-14 BETA 1.95E-02 1.33E-03 9.99E-03 pCi!m3 701 Avila Gate(356013002)- AP 30-Aug-14 BETA 2.51 E-02 1.32E-03 1.06E-02 pCi!m3 701 Avila Gate(356629002)- AP 6-Sep-14 BETA 2.77E-02 1.31 E-03 1.02E-02 pCi!m3 701 Avila Gate(357003002)- AP 13-Sep-14 BETA 5.31 E-02 1.31 E-03 1.07E-02 pCi!m3 701 Avila Gate(357441002)- AP 20-Sep-14 BETA 3.12E-02 1.19E-03 9.04E-03 pCi/m3 701 Avila Gate(357901 002)- AP 27-Sep-14 BETA 2.51 E-02 1.34E-03 1.01 E-02 pCi/m3 701 Avila Gate(358659002)- AP 4-0ct-14 BETA 5.80E-02 1.26E-03 1.16E-02 pCi/m3 701 Avila Gate(359172002)- AP 11-0ct-14 BETA 4.02E-02 1.37E-03 9.79E-03 pCi/m3 701 Avila Gate(359686002)- AP 18-0ct-14 BETA 1.33E-02 1.35E-03 9.96E-03 pCi!m3 701 Avila Gate(360173002)- AP 25-0ct-14 BETA 2.33E-02 1.35E-03 1.13E-02 pCi/m3 701 Avila Gate(360704002)- AP 1-Nov-14 BETA 3.03E-02 1.28E-03 1.18E-02 pCi/m3 701 Avila Gate(361184002) - AP 8-Nov-14 BETA 5.05E-02 1.38E-03 1.15E-02 pCi!m3 701 Avila Gate(361687002)- AP 15-Nov-14 BETA 5.96E-02 1.34E-03 1.17E-02 pCilm3 701 Avila Gate(362077002)- AP 22-Nov-14 BETA 2.49E-02 1.64E-03 1.27E-02 pCi!m3 701 Avila Gate(362293002)- AP 28-Nov-14 BETA 4.95E-02 1.45E-03 1.09E-02 pCi!m3 701 Avila Gate(362893002)- AP 6-0ec-14 BETA 2.06E-02 1.11 E-03 9.15E-03 pCi/m3 701 Avila Gate(363523002)- AP 13-0ec-14 BETA 1.40E-02 1.55E-03 1.11 E-02 pCi/m3 701 Avila Gate(363779002)- AP 20-0ec-14 BETA 6.37E-03 1.60E-03 1.27E-02 pCi!m3 701 Avila Gate(363946002)- AP 26-0ec-14 BETA 1.79E-02 1.34E-03 1.09E-02 pCi!m3 701 Avila Gate(347208002)- AP 14-Feb-14 Beryllium-?
1.17E-01 9.83E-03 2.16E-02 pCi!m3 701 Avila Gate(353206002)- AP 17-May-14 Beryllium-?
8.61 E-02 6.77E-03 1.61E-02 pCi!m3 701 Avila Gate(359403002)- AP 16-Aug-14 Beryllium-?
8.02E-02 1.28E-02 2.12E-02 pCi/m3 701 Avila Gate(365208002)- AP 15-Nov-14 Beryllium-?
9.96E-02 1.67E-02 2.71E-02 pCilm3 701 Avila Gate(347208002)- AP 14-Feb-14 Cesium-134
-4.41 E-05 6.77E-04 4.21 E-04 pCilm3 701 Avila Gate(353206002)- AP 17-May-14 Cesium-134 2.23E-04 6.87E-04 3.86E-04 pCi/m3 701 Avila Gate(359403002)- AP 16-Aug-14 Cesium-134 2.55E-04 7.59E-04 4.21 E-04 pCilm3 701 Avila Gate(365208002)- AP 15-Nov-14 Cesium-134 3.67E-04 1.50E-03 8.51 E-04 pCilm3 Page 33 of 92
2014 DCPP REMP Analysis Results Appendix C 7D1 Avila Gate(347208002)- AP 14-Feb-14 Cesium-137 2.79E-05 5.88E-04 4.03E-04 pCi/m3 7D1 Avila Gate(353206002)- AP 17-May-14 Cesium-137 1.94E-04 5.96E-04 3.36E-04 pCi/m3 7D1 Avila Gate(359403002)- AP 16-Aug-14 Cesium-137 1.94E-04 5.35E-04 2.89E-04 pCi/m3 7D1 Avila Gate(365208002)- AP 15-Nov-14 Cesium-137
-6.21 E-04 8.37E-04 6.86E-04 pCi/m3 7D3 Avila Pier-Market Fish Sample Name
- Date Collected Nuclide Result MDC 2 Sigma TPU Units 7D3 Avila Pier(346801001)- FH Market 8-Apr-14 Cesium-134
-4.06E-01 4.14E+OO 2.48E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Cesium-134 2.36E+OO 5.77E+OO 3.52E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Cesium-134
-3.82E-01 4.90E+OO 3.99E+OO pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Cesium-137 5.58E+OO 4.04E+OO 3.68E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Cesium-137 6.69E+OO 4.84E+OO 5.01 E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Cesium-137 4.42E+OO 5.12E+OO 3.45E+OO pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Cobalt-58 3.85E-01 4.21 E+OO 2.47E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Cobalt-58
-2.69E+OO 5.06E+OO 3.45E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Cobalt-58
-9.21 E-01 4.56E+OO 2.82E+OO pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Cobalt-60 2.37E+OO 4.91 E+OO 2.89E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Cobalt-60
-1.56E+OO 4.83E+OO 3.69E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Cobalt-60
-2.26E+OO 4.65E+OO 3.12E+OO pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Iron-59 1.12E+OO 1.04E+01 7.15E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Iron-59 2.54E+OO 1.27E+01 7.51 E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Iron-59
-1.58E+OO 1.02E+01 6.88E+OO pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Manganese-54 6.81 E-01 4.04E+OO 2.36E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Manganese-54
-3.41 E+OO 4.87E+OO 3.96E+OO pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Manganese-54
-1.15E+OO 4.04E+OO 2.56E+OO pCi/kg 7D3 Avila Pier(346801001)- FH Market 8-Apr-14 Potassium-40 2.80E+03 3.54E+01 2.73E+02 pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Potassium-40 3.40E+03 4.37E+01 3.23E+02 pCi/kg 7D3 Avila Pier(360354003)- FH Market 28-0ct-14 Potassium-40 3.97E+03 4.20E+01 3.72E+02 pCi/kg 7D3 Avila Pier(346801 001)- FH Market 8-Apr-14 Zinc-65 5.74E+OO 1.05E+01 6.51 E+OO pCi/kg 7D3 Avila Pier(353828001)- FH Market 29-Jul-14 Zinc-65
-3.80E+OO 1.25E+01 7.83E+OO pCi/kg 7D3 Avila Pier(360354003) - FH Market 28-0ct-14 Zinc-65
-2.53E+OO 1.13E+01 7.95E+OO pCi/kg Page 34 of 92
2014 DCPP REMP Analysis Results Appendix C 7E1 Avila Valley Barn-Vegetation Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 7E1 Avila Valley Barn(346801 002)- VG Brdleaf 8-Apr-14 Cesium-134 1.44E+OO 4.22E+OO 2.42E+OO pCi/kg 7E1 Avila Valley Barn(353828002)- VG Brdleaf 29-Jul-14 Cesium-134 2.71E+OO 5.94E+OO 4.20E+OO pCi/kg 7E1 Avila Valley Barn(360804003)- VG Brdleaf 4-Nov-14 Cesium-134 1.38E+OO 6.96E+OO 4.03E+OO pCi/kg 7E1 Avila Valley Barn(346801 002)- VG Brdleaf 8-Apr-14 Cesium-137 8.83E-01 3.91E+OO 2.27E+OO pCilkg 7E1 Avila Valley Barn(353828002)- VG Brdleaf 29-Jul-14 Cesium-137
-7.63E-02 5.40E+OO 3.79E+OO pCi/kg 7E1 Avila Valley Barn(360804003)- VG Brdleaf 4-Nov-14 Cesium-137
-3.28E+OO 6.12E+OO 5.30E+OO pCilkg 7E1 Avila Valley Barn(346801 002)- VG Brdleaf 8-Apr-14 lodine-131 2.17E+OO 6.82E+OO 4.07E+OO pCi/kg 7E1 Avila Valley Barn(353828002)- VG Brdleaf 29-Jul-14 lodine-131
-2.10E+OO 9.35E+OO 5.67E+OO pCi!kg 7E1 Avila Valley Barn(360804003)- VG Brdleaf 4-Nov-14 lodine-131 6.13E+OO 1.81 E+01 1.77E+01 pCilkg 7E1 Avila Valley Barn(346801 002)- VG Brdleaf 8-Apr-14 Potassium-40 1.98E+03 3.19E+01 2.02E+02 pCi!kg 7E1 Avila Valley Barn(353828002)- VG Brdleaf 29-Jul-14 Potassium-40 1.51 E+03 5.48E+01 1.78E+02 pCi/kg 7E1 Avila Valley Barn(360804003)- VG Brdleaf 4-Nov-14 Potassium-40 2.62E+03 4.78E+01 2.71 E+02 pCi/kg 7G1 Arroyo Grande-Vegetation Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 7G1 Arroyo Grande(344064002)- VG Brdleaf 4-Mar-14 Beryllium-?
1.43E+02 7.60E+01 6.69E+01 pCi/kg 7G1 Arroyo Grande(363443003)- VG Brdleaf 15-Dec-14 Beryllium-?
3.55E+02 4.72E+01 6.37E+01 pCi/kg 7G1 Arroyo Grande(341390002)- VG Brdleaf 13-Jan-14 Cesium-134
-7.17E-01 8.17E+OO 7.32E+OO pCi!kg 7G1 Arroyo Grande(342580002) - VG Brdleaf 4-Feb-14 Cesium-134
-8.75E-01 1.05E+01 6.15E+OO pCilkg 7G1 Arroyo Grande(344064002) - VG Brdleaf 4-Mar-14 Cesium-134 1.37E+OO 9.66E+OO 5.82E+OO pCi/kg 7G1 Arroyo Grande(346436002)- VG Brdleaf 8-Apr-14 Cesium-134 3.06E+OO 6.76E+OO 4.05E+OO pCi!kg 7G1 Arroyo Grande(348318002)- VG Brdleaf 6-May-14 Cesium-134
-1.84E+OO 1.14E+01 7.14E+OO pCi/kg 7G1 Arroyo Grande(350126002)- VG Brdleaf 3-Jun-14 Cesium-134 2.64E+OO 5.97E+OO 3.52E+OO pCilkg 7G1 Arroyo Grande(352360003)- VG Brdleaf 8-Jul-14 Cesium-134 5.62E+OO 9.85E+OO 6.76E+OO pCi/kg 7G1 Arroyo Grande(354262002)- VG Brdleaf 5-Aug-14 Cesium-134
-7.99E-01 7.77E+OO 7.25E+OO pCi/kg 7G1 Arroyo Grande(355958003)- VG Brdleaf 2-Sep-14 Cesium-134
-1.09E+OO 9.36E+OO 6.44E+OO pCi/kg 7G1 Arroyo Grande(358519003)- VG Brdleaf 6-0ct-14 Cesium-134
-3.49E+OO 1.03E+01 6.80E+OO pCilkg 7G1 Arroyo Grande(360563003)- VG Brdleaf 3-Nov-14 Cesium-134 1.79E-02 1.01 E+01 7.02E+OO pCi/kg 7G1 Arroyo Grande(363443003) - VG Brdleaf 15-Dec-14 Cesium-134 4.27E+OO 6.94E+OO 3.91 E+OO pCi/kg 7G1 Arroyo Grande(341390002)- VG Brdleaf 13-Jan-14 Cesium-137 1.93E+OO 8.88E+OO 6.02E+OO pCi/kg 7G1 Arroyo Grande(342580002)- VG Brdleaf 4-Feb-14 Cesium-137 4.83E+OO 1.04E+01 6.40E+OO pCi/kg 7G1 Arroyo Grande(344064002)- VG Brdleaf 4-Mar-14 Cesium-137 3.30E-01 9.08E+OO 5.44E+OO pCi/kg 7G1 Arroyo Grande(346436002) - VG Brdleaf 8-Apr-14 Cesium-137 2.56E+OO 6.87E+OO 5.63E+OO pCi/kg 7G1 Arroyo Grande(348318002)- VG Brdleaf 6-May-14 Cesium-137 7.68E+OO 1.10E+01 1.31E+01 pCi/kg 7G1 Arroyo Grande(350126002)- VG Brdleaf 3-Jun-14 Cesium-137 2.37E+OO 6.02E+OO 3.68E+OO pCilkg 7G1 Arroyo Grande(352360003)- VG Brdleaf 8-Jul-14 Cesium-137 2.72E+OO 8.71 E+OO 5.90E+OO pCi/kg 7G1 Arroyo Grande(354262002)- VG Brdleaf 5-Aug-14 Cesium-137
-4.60E+OO 7.56E+OO 5.35E+OO pCilkg 7G1 Arroyo Grande(355958003)- VG Brdleaf 2-Sep-14 Cesium-137
-2.03E+OO 8.33E+OO 5.24E+OO pCilkg 7G1 Arroyo Grande(358519003)- VG Brdleaf 6-0ct-14 Cesium-137 1.19E+OO 1.05E+01 6.27E+OO pCi/kg 7G1 Arroyo Grande(360563003) - VG Brdleaf 3-Nov-14 Cesium-137 6.48E-01 9.61 E+OO 1.16E+01 pCi/kg 7G1 Arroyo Grande(363443003)- VG Brdleaf 15-Dec-14 Cesium-137
-1.45E+OO 6.20E+OO 3.81E+OO pCilkg 7G1 Arroyo Grande(341390002)- VG Brdleaf 13-Jan-14 lodine-131
-5.73E+OO 9.23E+OO 6.48E+OO pCi!kg Page 35 of 92
2014 DCPP REMP Analysis Results Appendix C 7G1 Arroyo Grande(342580002)- VG Brdleaf 4-Feb-14 lodine-131
-1.98E+OO 1.15E+01 6.87E+OO pCi/kg 7G1 Arroyo Grande(344064002)- VG Brdleaf 4-Mar-14 lodine-131 6.24E+OO 1.53E+01 1.06E+01 pCi/kg 7G1 Arroyo Grande(346436002)- VG Brdleaf 8-Apr-14 lodine-131 2.81E+OO 7.49E+OO 4.70E+OO pCi/kg 7G1 Arroyo Grande(348318002)- VG Brdleaf 6-May-14 lodine-131
-2.16E+OO 1.54E+01 9.31E+OO pCi/kg 7G1 Arroyo Grande(350126002)- VG Brdleaf 3-Jun-14 lodine-131
-2.88E-01 9.21E+OO 5.43E+OO pCi/kg 7G1 Arroyo Grande(352360003)- VG Brdleaf 8-Jul-14 lodine-131 6.57E-01 1.09E+01 6.53E+OO pCi/kg 7G1 Arroyo Grande(354262002)- VG Brdleaf 5-Aug-14 lodine-131
-2.75E+OO 9.65E+OO 5.94E+OO pCi/kg 7G1 Arroyo Grande(355958003)- VG Brdleaf 2-Sep-14 lodine-131 8.03E-01 1.39E+01 8.46E+OO pCi/kg 7G1 Arroyo Grande(358519003)- VG Brdleaf 6-0ct-14 lodine-131 3.35E+OO 1.36E+01 8.28E+OO pCi/kg 7G1 Arroyo Grande(360563003)- VG Brdleaf 3-Nov-14 lodine-131 4.57E-01 1.30E+01 7.89E+OO pCi/kg 7G1 Arroyo Grande(363443003)- VG Brdleaf 15-Dec-14 lodine-131 3.23E+OO 1.11E+01 6.73E+OO pCi/kg 7G1 Arroyo Grande(342580002)- VG Brdleaf 4-Feb-14 Potassium-40 3.93E+03 7.43E+01 4.11 E+02 pCi/kg 7G1 Arroyo Grande(344064002)- VG Brdleaf 4-Mar-14 Potassium-40 3.03E+03 8.00E+01 3.45E+02 pCi/kg 7G1 Arroyo Grande(346436002) - VG Brdleaf 8-Apr-14 Potassium-40 2.19E+03 6.10E+01 2.47E+02 pCi/kg 7G1 Arroyo Grande(348318002)- VG Brdleaf 6-May-14 Potassium-40 3.57E+03 8.71E+01 3.98E+02 pCi/kg 7G1 Arroyo Grande(350126002)- VG Brdleaf 3-Jun-14 Potassium-40 2.70E+03 4.84E+01 2.88E+02 pCi/kg 7G1 Arroyo Grande(352360003)- VG Brdleaf 8-Jul-14 Potassium-40 2.55E+03 8.16E+01 3.02E+02 pCi/kg 7G1 Arroyo Grande(354262002)- VG Brdleaf 5-Aug-14 Potassium-40 2.94E+03 8.25E+01 3.29E+02 pCi/kg 7G1 Arroyo Grande(355958003)- VG Brdleaf 2-Sep-14 Potassium-40 2.63E+03 6.82E+01 3.03E+02 pCi/kg 7G1 Arroyo Grande(358519003)- VG Brdleaf 6-0ct-14 Potassium-40 3.69E+03 9.78E+01 4.07E+02 pCi/kg 7G1 Arroyo Grande(360563003)- VG Brdleaf 3-Nov-14 Potassium-40 3.66E+03 9.17E+01 3.97E+02 pCi/kg 7G1 Arroyo Grande(363443003)- VG Brdleaf 15-Dec-14 Potassium-40 3.11 E+03 5.89E+01 3.20E+02 pCi/kg 8S1 Target Range-Air Charcoal Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S1 Target Range(340937011)- AC 3-Jan-14 lodine-131 4.44E-03 9.05E-03 6.87E-03 pCi/m3 8S1 Target Range(341469011)- AC 11-Jan-14 lodine-131 4.70E-03 1.12E-02 6.45E-03 pCi/m3 8S1 Target Range(341857011)- AC 18-Jan-14 lodine-131 1.22E-02 2.24E-02 1.31E-02 pCi/m3 8S1 Target Range(342138011)- AC 25-Jan-14 lodine-131 2.26E-03 1.01 E-02 5.87E-03 pCi/m3 8S1 Target Range(342582011)- AC 1-Feb-14 lodine-131
-6.85E-04 1.12E-02 6.96E-03 pCi/m3 8S1 Target Range(343015011)- AC 8-Feb-14 lodine-131
-2.62E-03 1.12E-02 7.25E-03 pCi/m3 8S1 Target Range(343355011)- AC 15-Feb-14 lodine-131 2.42E-03 1.03E-02 5.92E-03 pCi/m3 8S1 Target Range(343769011)- AC 22-Feb-14 lodine-131
-4.64E-03 9.31 E-03 6.44E-03 pCi/m3 8S1 Target Range(344077011)- AC 1-Mar-14 lodine-131 5.43E-03 1.08E-02 6.45E-03 pCi/m3 8S1 Target Range(344522011)- AC 8-Mar-14 lodine-131
-5.77E-04 1.04E-02 6.38E-03 pCi/m3 8S1 Target Range(34494701 0)- AC 15-Mar-14 lodine-131
-3.55E-03 7.33E-03 5.35E-03 pCi/m3 8S1 Target Range(345381 011)- AC 23-Mar-14 lodine-131 8.09E-04 9.38E-03 5.41 E-03 pCi/m3 8S1 Target Range(345737011)- AC 29-Mar-14 lodine-131 2.68E-03 9.44E-03 5.51 E-03 pCi/m3 8S1 Target Range(346448011)- AC 5-Apr-14
. lodine-131
-2.11 E-04 1.31E-02 7.75E-03 pCi/m3 8S1 Target Range(346883011)- AC 12-Apr-14 lodine-131 6.06E-03 1.20E-02 7.61 E-03 pCi/m3 8S1 Target Range(347387003)- AC 19-Apr-14 lodine-131 6.63E-03 8.93E-03 7.37E-03 pCi/m3 8S1 Target Range(347862011)- AC 26-Apr-14 lodine-131
-3.51 E-02 4.29E-02 3.52E-02 pCi/m3 8S1 Target Range(348342011) - AC 3-May-14 lodine-131
-2.62E-03 1.20E-02 7.44E-03 pCi/m3 8S1 Target Range(348779011)- AC 10-May-14 lodine-131
-3.14E-03 9.74E-03 6.29E-03 pCi/m3 8S1 Target Range(349262011)- AC 17-May-14 lodine-131 3.21 E-03 1.77E-02 1.01 E-02 pCi/m3 Page 36 of 92
2014 DCPP REMP Analysis Results Appendix C 8S1 Target Range(349563011)- AC 24-May-14 lodine-131
-3.48E-03 9.11E-03 6.21 E-03 pCi/m3 8S1 Target Range(350052011)- AC 31-May-14 lodine-131
-5.79E-04 9.91 E-03 5.94E-03 pCi/m3 8S1 Target Range(350455011) - AC 7-Jun-14 lodine-131
-7.58E-04 1.18E-02 7.23E-03 pCilm3 8S1 Target Range(350986011)- AC 14-Jun-14 lodine-131 1.85E-03 7.99E-03 4.66E-03 pCilm3 8S1 Target Range(351433011)- AC 21-Jun-14 lodine-131
-8.85E-04 1.02E-02 6.22E-03 pCi/m3 8S1 Target Range(351789011)- AC 28-Jun-14 lodine-131
-5.48E-04 1.59E-02 9.56E-03 pCi/m3 8S1 Target Range(352368011)- AC 5-Jul-14 lodine-131
-5.51 E-03 1.53E-02 1.04E-02 pCilm3 8S1 Target Range(35284901 0)- AC 12-Jul-14 lodine-131
-2.30E-03 9.60E-03 7.07E-03 pCilm3 8S1 Target Range(353399011)- AC 19-Jul-14 lodine-131
-7.01 E-03 1.24E-02 1.02E-02 pCi/m3 8S1 Target Range(353786011)- AC 26-Jul-14 lodine-131
-3.94E-03 1.10E-02 7.63E-03 pCilm3 8S1 Target Range(354272011)- AC 2-Aug-14 lodine-131
-3.91 E-04 1.14E-02 6.89E-03 pCilm3 8S1 Target Range(354689011)- AC 9-Aug-14 lodine-131 3.09E-03 1.24E-02 6.97E-03 pCilm3 8S1 Target Range(355193011)- AC 16-Aug-14 lodine-131 4.00E-04 1.29E-02 7.79E-03 pCi/m3 8S1 Target Range(355650011)- AC 23-Aug-14 lodine-131
-5.85E-03 2.01 E-02 1.29E-02 pCi/m3 8S 1 Target Range(356013011) - AC 30-Aug-14 lodine-131 7.80E-03 1.43E-02 8.33E-03 pCilm3 8S1 Target Range(356629011)- AC 6-Sep-14 lodine-131 5.07E-03 1.48E-02 9.10E-03 pCi/m3 8S1 Target Range(357003011)- AC 13-Sep-14 lodine-131 6.09E-03 2.07E-02 1.20E-02 pCilm3 8S1 Target Range(357441011)- AC 20-Sep-14 lodine-131
-6.67E-04 1.49E-02 8.83E-03 pCilm3 8S1 Target Range(357901 011)- AC 27-Sep-14 lodine-131 8.85E-04 1.57E-02 9.74E-03 pCi/m3 8S1 Target Range(358659011)- AC 4-0ct-14 lodine-131 3.01 E-03 1.36E-02 7.67E-03 pCilm3 8S1 Target Range(359172011)- AC 11-0ct-14 lodine-131
-7.99E-04 9.51 E-03 5.89E-03 pCi/m3 8S1 Target Range(359686011)- AC 18-0ct-14 lodine-131 6.78E-04 9.83E-03 5.70E-03 pCi/m3 8S1 Target Range(360173011)- AC 25-0ct-14 lodine-131 1.51 E-04 1.12E-02 6.74E-03 pCilm3 8S1 Target Range(360704011)- AC 1-Nov-14 lodine-131 4.21 E-04 9.35E-03 5.96E-03 pCi/m3 8S1 Target Range(361184011)- AC 8-Nov-14 lodine-131 9.56E-05 1.34E-02 8.03E-03 pCilm3 8S1 Target Range(361687011)- AC 15-Nov-14 lodine-131
-3.11 E-03 6.86E-03 5.00E-03 pCi/m3 8S1 Target Range(362077011)- AC 22-Nov-14 lodine-131 6.97E-03 1.07E-02 6.15E-03 pCi/m3 8S1 Target Range(362293011)- AC 28-Nov-14 lodine-131
-4.04E-03 1.27E-02 8.23E-03 pCilm3 8S1 Target Range(362893011)- AC 6-Dec-14 lodine-131 2.55E-03 1.50E-02 8.55E-03 pCilm3 8S1 Target Range(363523011)- AC 13-Dec-14 lodine-131 4.02E-03 1.19E-02 7.59E-03 pCilm3 8S1 Target Range(363779012)- AC 20-Dec-14 lodine-131
-5.82E-03 1.46E-02 1.04E-02 pCi/m3 8S1 Target Range(363946012)- AC 26-Dec-14 lodine-131
-4.37E-03 1.27E-02 8.43E-03 pCilm3 8S1 Target Range-Air Carbon 14 Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S1 Target Range(341293001)- AC14 3-Jan-14 Carbon-14
-2.60E-07 4.71 E-07 2.76E-07 uCilm3 8S1 Target Range(341720001)- AC14 11-Jan-14 Carbon-14
-6.76E-08 5.69E-07 3.38E-07 uCilm3 8S1 Target Range(342040001)- AC14 18-Jan-14 Carbon-14
-2.69E-08 4.91 E-07 2.92E-07 uCilm3 8S1 Target Range(342382001)- AC14 25-Jan-14 Carbon-14 2.68E-08 5.18E-07 3.09E-07 uCilm3 8S1 Target Range(342814001)- AC14 1-Feb-14 Carbon-14 1.80E-07 5.63E-07 3.39E-07 uCi/m3 8S1 Target Range(343015015)- AC14 8-Feb-14 Carbon-14 3.84E-08 5.58E-07 3.33E-07 uCilm3 8S1 Target Range(343355015)- AC14 15-Feb-14 Carbon-14
-4.71 E-08 6.14E-07 3.65E-07 uCilm3 8S1 Target Range(343769015)- AC14 22-Feb-14 Carbon-14
-1.84E-09 6.57E-07 3.91 E-07 uCilm3 8S1 Target Range(344077015)- AC14 1-Mar-14 Carbon-14 1.31E-07 6.42E-07 3.85E-07 uCi/m3 8S1 Target Range(344522015)- AC14 8-Mar-14 Carbon-14
-2.46E-07 7.11E-07 4.19E-07 uCilm3 Page 37 of 92
2014 DCPP REMP Analysis Results Appendix C 8S1 Target Range(344947013)- AC14 15-Mar-14 Carbon-14
-2.76E-07 5.76E-07 3.38E-07 uCi/m3 8S1 Target Range(345381015)- AC14 23-Mar-14 Carbon-14
-2.93E-07 6.39E-07 3.75E-07 uCi/m3 8S1 Target Range(345737015)- AC14 29-Mar-14 Carbon-14 3.90E-07 5.25E-07 3.20E-07 uCi/m3 8S1 Target Range(346448015)- AC14 5-Apr-14 Carbon-14 2.87E-07 5.90E-07 3.57E-07 uCi/m3 8S1 Target Range(346883015)- AC14 12-Apr-14 Carbon-14
-3.89E-07 6.48E-07 3.79E-07 uCi/m3 8S1 Target Range(347387015)- AC14 19-Apr-14 Carbon-14 3.79E-07 5.26E-07 3.21 E-07 uCi/m3 8S1 Target Range(347862015)- AC14 26-Apr-14 Carbon-14 2.20E-06 3.26E-06 1.99E-06 uCi/m3 8S1 Target Range(348342015)- AC14 3-May-14 Carbon-14 9.56E-08 4.63E-07 2.78E-07 uCi/m3 8S1 Target Range(348779015)- AC14 10-May-14 Carbon-14 3.07E-d7 5.32E-07 3.23E-07 uCi/m3 8S1 Target Range(349262015)- AC14 17-May-14 Carbon-14 4.30E-07 5.95E-07 3.63E-07 uCi/m3 8S1 Target Range(349563015)- AC14 24-May-14 Carbon-14 3.68E-07 5.34E-07 3.25E-07 uCi/m3 8S1 Target Range(350052015)- AC14 31-May-14 Carbon-14 4.29E-07 5.48E-07 3.34E-07 uCi/m3 8S1 Target Range(350455015)- AC14 7-Jun-14 Carbon-14 3.09E-08 7.72E-07 4.60E-07 uCi/m3 8S1 Target Range(350986015)- AC14 14-Jun-14 Carbon-14
-9.23E-09 5.05E-07 3.01 E-07 uCi/m3 8S1 Target Range(351433015)- AC14 21-Jun-14 Carbon-14
-1.67E-07 5.68E-07 3.35E-07 uCi/m3 8S1 Target Range(351789015)- AC14 28-Jun-14 Carbon-14
-3.22E-07 6.70E-07 3.93E-07 uCi/m3 8S1 Target Range(352368015)- AC14 5-Jul-14 Carbon-14
-3.32E-07 6.91 E-07 4.05E-07 uCi/m3 8S1 Target Range(352849014)- AC14 12-Jul-14 Carbon-14 8.70E-08 7.03E-07 4.20E-07 uCi/m3 8S1 Target Range(353399015)- AC14 19-Jul-14 Carbon-14
-3.35E-07 5.87E-07 3.43E-07 uCi/m3 8S1 Target Range(353786015)- AC14 26-Jul-14 Carbon-14
-2.37E-08 6.08E-07 3.62E-07 uCi/m3 8S1 Target Range(354272015)- AC14 2-Aug-14 Carbon-14
-4.77E-07 5.67E-07 3.29E-07 uCi/m3 8S1 Target Range(354689016)- AC14 9-Aug-14 Carbon-14
-2.76E-07 7.26E-07 4.27E-07 uCi/m3 8S1 Target Range(355193016)- AC14 16-Aug-14 Carbon-14
-6.04E-07 8.31 E-07 4.83E-07 uCi/m3 8S1 Target Range(355650016)- AC14 23-Aug-14 Carbon-14
-7.58E-08 7.25E-07 4.30E-07 uCi/m3 8S1 Target Range(356013016) -AC14 30-Aug-14 Carbon-14 3.46E-07 8.16E-07 4.93E-07 uCi/m3 8S1 Target Range(356629016)- AC14 6-Sep-14 Carbon-14
-1.17E-07 7.98E-07 4.73E-07 uCi/m3 8S1 Target Range(357003016)- AC14 13-Sep-14 Carbon-14 5.07E-07 7.79E-07 4.75E-07 uCi/m3 8S1 Target Range(357441 016)- AC14 21-Sep-14 Carbon-14
-1.34E-07 6.82E-07 4.04E-07 uCi/m3 8S1 Target Range(357901016)- AC14 28-Sep-14 Carbon-14 2.85E-07 5.79E-07 3.51 E-07 uCi/m3 8S1 Target Range(358659016)- AC14 4-0ct-14 Carbon-14
-1.81 E-07 6.34E-07 3.74E-07 uCi/m3 8S1 Target Range(359172016)- AC14 11-0ct-14 Carbon-14 4.58E-07 5.84E-07 3.56E-07 uCi/m3 8S1 Target Range(359686016)- AC14 18-0ct-14 Carbon-14
-8.53E-08 6.27E-07 3.72E-07 uCi/m3 8S1 Target Range(360173016)- AC14 25-0ct-14 Carbon-14
-4.60E-07 6.34E-07 3.69E-07 uCi/m3 8S1 Target Range(360704016)- AC14 1-Nov-14 Carbon-14
-1.89E-07 6.53E-07 3.85E-07 uCi/m3 8S1 Target Range(361184016) -AC14 8-Nov-14 Carbon-14 9.63E-08 6.96E-07 4.16E-07 uCi/m3 8S1 Target Range(361687016)- AC14 15-Nov-14 Carbon-14
-2.15E-07 7.03E-07 4.15E-07 uCi/m3 8S1 Target Range(362077016)- AC14 22-Nov-14 Carbon-14
-4.44E-07 8.37E-07 4.90E-07 uCi/m3 8S1 Target Range(362293016)- AC14 28-Nov-14 Carbon-14
-4.15E-08 6.90E-07 4.11 E-07 uCi/m3 8S1 Target Range(362893016)- AC14 6-Dec-14 Carbon-14
-1.82E-07 5.82E-07 3.44E-07 uCi/m3 8S1 Target Range(363523016)- AC14 13-Dec-14 Carbon-14
-1.40E-09 6.56E-07 3.91 E-07 uCi/m3 8S1 Target Range(363779016)- AC14 20-Dec-14 Carbon-14
-5.82E-07 7.32E-07 4.26E-07 uCi/m3 8§_1_Ta~g~t__Ba_Q_ge(3639460_1_6)- AC14 26-Dec-14 Carbon-14 1.84E-07 6.30E-07 3.79E-07 uCi/m3 Page 38 of 92
2014 DCPP REMP Analysis Results Appendix C 8S1 Target Range-Air Particulate Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S1 Target Range(340937004)- AP 3-Jan-14 BETA 1.11 E-01 1.01 E-03 1.05E-02 pCi/m3 8S1 Target Range(341469004)- AP 11-Jan-14 BETA 4.04E-02 1.31 E-03 1.02E-02 pCi/m3 8S1 Target Range(341857004)- AP 18-Jan-14 BETA 8.59E-02 1.25E-03 1.23E-02 pCi/m3 8S1 Target Range(342138004)- AP 25-Jan-14 BETA 9.29E-02 1.38E-03 1.35E-02 pCi/m3 8S1 Target Range(342582004) - AP 1-Feb-14 BETA 1.23E-02 1.32E-03 1.07E-02 pCi/m3 8S1 Target Range(343015004)- AP 8-Feb-14 BETA 1.14E-02 1.33E-03 9.58E-03 pCi/m3 8S1 Target Range(343355004)- AP 15-Feb-14 BETA 1.96E-02 1.37E-03 9.78E-03 pCi/m3 8S1 Target Range(343769004)- AP 22-Feb-14 BETA 2.79E-02 1.32E-03 1.05E-02 pCi/m3 8S1 Target Range(344077004)- AP 1-Mar-14 BETA 1.32E-02 1.32E-03 1.. 08E-02 pCi/m3 8S1 Target Range(344522004)- AP 8-Mar-14 BETA 2.27E-02 1.28E-03 1.18E-02 pCi/m3 8S1 Target Range(344947004)- AP 15-Mar-14 BETA 2.77E-02 1.30E-03 1.01 E-02 pCi/m3 8S1 Target Range(345381004)- AP 23-Mar-14 BETA 2.27E-02 1.31 E-03 1.21E-02 pCi/m3 8S1 Target Range(345737004)- AP 29-Mar-14 BETA 8.24E-03 1.18E-03 8.69E-03 pCi/m3 8S1 Target Range(346448004)- AP 5-Apr-14 BETA 2.12E-02 1.27E-03 8.92E-03 pCi/m3 8S1 Target Range(346883004)- AP 12-Apr-14 BETA 2.84E-02 1.26E-03 9.72E-03 pCi/m3 8S1 Target Range(347387011)- AP 19-Apr-14 BETA 2.06E-02 1.32E-03 8.76E-03 pCi/m3 8S1 Target Range(347862004)- AP 26-Apr-14 BETA 2.09E-02 7.86E-03 5.09E-02 pCi/m3 8S1 Target Range(348342004)- AP 3-May-14 BETA 2.39E-02 1.34E-03 9.86E-03 pCi/m3 8S1 Target Range(348779004)- AP 10-May-14 BETA 1.84E-02 1.49E-03 9.25E-03 pCi/m3 8S1 Target Range(349262004) - AP 17-May-14 BETA 2.13E-02 1.39E-03 1.06E-02 pCi/m3 8S1 Target Range(349563004)- AP 24-May-14 BETA 1.02E-02 1.30E-03 8.51 E-03 pCi/m3 8S1 Target Range(350052004)- AP 31-May-14 BETA 1.31E-02 1.20E-03 1.02E-02 pCi/m3 8S1 Target Range(350455004)- AP 7-Jun-14 BETA 1.22E-02 1.78E-03 1.25E-02 pCi/m3 8S1 Target Range(350986004)- AP 14-Jun-14 BETA 1.35E-02 1.13E-03 8.33E-03 pCi/m3 8S1 Target Range(351433004)- AP 21-Jun-14 BETA 7.12E-03 1.36E-03 9.35E-03 pCi/m3 8S1 Target Range(351789004)- AP 28-Jun-14 BETA 4.38E-03 1.46E-03 1.11 E-02 pCi/m3 8S1 Target Range(352368004)- AP 5-Jul-14 BETA 1.11 E-02 1.44E-03 8.73E-03 pCi/m3 8S1 Target Range(352849004)- AP 12-Jul-14 BETA 8.66E-03 1.33E-03 1.11 E-02 pCi/m3 8S1 Target Range(353399004)- AP 19-Jul-14 BETA 1.86E-02 1.32E-03 1.14E-02 pCi/m3 8S1 Target Range(353786004)- AP 26-Jul-14 BETA 1.42E-02 1.27E-03 1.11 E-02 pCi/m3 8S1 Target Range(354272004)- AP 2-Aug-14 BETA 1.71 E-02 1.38E-03 9.72E-03 pCi/m3 8S1 Target Range(354689004) - AP 9-Aug-14 BETA 1.18E-02 1.34E-03 9.96E-03 pCi/m3 8S1 Target Range(355193004)- AP 16-Aug-14 BETA 1.38E-02 1.39E-03 9.18E-03 pCi/m3 8S1 Target Range(355650004)- AP 23-Aug-14 BETA 1.99E-02 1.33E-03 1.01 E-02 pCi/m3 8S1 Target Range(356013004)- AP 30-Aug-14 BETA 1.72E-02 1.35E-03 1.06E-02 pCi/m3 8S1 Target Range(356629004)- AP 6-Sep-14 BETA 2.68E-02 1.33E-03 1.03E-02 pCi/m3 8S1 Target Range(357003004)- AP 13-Sep-14 BETA 4.51 E-02 1.32E-03 1.06E-02 pCi/m3 8S1 Target Range(357441004)- AP 20-Sep-14 BETA 2.77E-02 1.21 E-03 9.09E-03 pCi/m3 8S1 Target Range(357901 004)- AP 27-Sep-14 BETA 2.13E-02 1.36E-03 1.01 E-02 pCi/m3 8S1 Target Range(358659004)- AP 4-0ct-14 BETA 5.72E-02 1.26E-03 1.15E-02 pCi/m3 8S1 Target Range(359172004)- AP 11-0ct-14 BETA 3.48E-02 1.42E-03 9.97E-03 pCi/m3 8S1 Target Range(359686004)- AP 18-0ct-14 BETA 1.79E-02 1.32E-03 9.88E-03 pCi/m3 Page 39 of 92
2014 DCPP REMP Analysis Results Appendix C 8S1 Target Range(360173004)- AP 25-0ct-14 BETA 2.16E-02 1.33E-03 1.12E-02 pCi/m3 8S1 Target Range(360704004)- AP 1-Nov-14 BETA 2.75E-02 1.37E-03 1.25E-02 pCilm3 8S1 Target Range(361184004)- AP 8-Nov-14 BETA 4.49E-02 1.37E-03 1.13E-02 pCilm3 8S1 Target Range(361687004)- AP 15-Nov-14 BETA 5.00E-02 1.37E-03 1.17E-02 pCilm3 8S1 Target Range(362077004)- AP 22-Nov-14 BETA 2.41 E-02 1.67E-03 1.29E-02 pCi/m3 8S1 Target Range(362293004)- AP 28-Nov-14 BETA 4.80E-02 1.45E-03 1.08E-02 pCilm3 8S1 Target Range(362893004)- AP 6-Dec-14 BETA 1.77E-02 1.11 E-03 9.12E-03 pCilm3 8S1 Target Range(363523004)- AP 13-Dec-14 BETA 1.34E-02 1.28E-03 9.15E-03 pCilm3 8S1 Target Range(363779005)- AP 20-Dec-14 BETA 1.01 E-02 1.67E-03 1.33E-02 pCi!m3 8S1 Target Range(363946005)- AP 26-Dec-14 BETA 2.1 OE-02 1.42E-03 1.16E-02 pCi/m3 8S1 Target Range(347208004)- AP 14-Feb-14 Beryllium-?
1.22E-01 1.17E-02 2.31 E-02 pCilm3 8S1 Target Range(353206004)- AP 17-May-14 Beryllium-?
8.84E-02 8.41 E-03 1.63E-02 pCilm3 8S1 Target Range(359403004)- AP 16-Aug-14 Beryllium-?
7.86E-02 1.13E-02 1.79E-02 pCilm3 8S1 Target Range(365208004)- AP 15-Nov-14 Beryllium-?
9.94E-02 1.16E-02 2.33E-02 pCilm3 8S1 Target Range(347208004)- AP 14-Feb-14 Cesium-134
-2.13E-04 9.22E-04 6.17E-04 pCilm3 8S1 Target Range(353206004)- AP 17-May-14 Cesium-134 3.72E-05 5.93E-04 3.45E-04 pCilm3 8S1 Target Range(359403004)- AP 16-Aug-14 Cesium-134 2.38E-04 8.54E-04 4.67E-04 pCilm3 8S1 Target Range(365208004)- AP 15-Nov-14 Cesium-134 4.13E-04 1.19E-03 6.54E-04 pCi/m3 8S1 Target Range(347208004)- AP 14-Feb-14 Cesium-137
-1.03E-04 5.42E-04 3.56E-04 pCi/m3 8S1 Target Range(353206004)- AP 17-May-14 Cesium-137 2.18E-05 4.74E-04 2.75E-04 pCi/m3 8S1 Target Range(359403004)- AP 16-Aug-14 Cesium-137 1.11 E-04 6.05E-04 3.58E-04 pCilm3 8S1 Target Range(365208004)- AP 15-Nov-14 Cesium-137
-3.71 E-04 7.95E-04 5.85E-04 pCi/m3 8S2 SW Site Boundary -Air Charcoal Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S2 SW Site Boundary(34093701 0) - AC 3-Jan-14 lodine-131 1.43E-03 7.55E-03 4.23E-03 pCilm3 8S2 SW Site Boundary(34146901 0) - AC 11-Jan-14 lodine-131
-2.18E-03 1.01 E-02 6.41 E-03 pCi/m3 8S2 SW Site Boundary(34185701 0) - AC 18-Jan-14 lodine-131 9.23E-03 9.23E-03 6.76E-03 pCi/m3 8S2 SW Site Boundary(34213801 0)- AC 25-Jan-14 lodine-131 1.46E-03 1.09E-02 6.19E-03 pCilm3 8S2 SW Site Boundary(34258201 0) - AC 1-Feb-14 lodine-131
-9.62E-04 8.84E-03 5.58E-03 pCi/m3 8S2 SW Site Boundary(34301501 0)- AC 8-Feb-14 lodine-131
-2.67E-03 1.23E-02 7.90E-03 pCilm3 8S2 SW Site Boundary(34335501 0) - AC 15-Feb-14 lodine-131
-1.02E-03 9.40E-03 5.78E-03 pCilm3 8S2 SW Site Boundary(34376901 0) - AC 22-Feb-14 lodine-131
-6.77E-03 9.55E-03 8.04E-03 pCilm3 8S2 SW Site Boundary(34407701 0) - AC 1-Mar-14 lodine-131
-2.58E-03 9.53E-03 6.14E-03 pCilm3 8S2 SW Site Boundary(34452201 0) - AC 8-Mar-14 lodine-131
-2.82E-04 9.36E-03 5.59E-03 pCi/m3 8S2 SW Site Boundary(344947009)- AC 15-Mar-14 lodine-131
-2.92E-03 8.50E-03 5.56E-03 pCilm3 8S2 SW Site Boundary(345381010)- AC 22-Mar-14 lodine-131 4.11 E-03 1.16E-02 6.57E-03 pCilm3 8S2 SW Site Boundary(34573701 0)- AC 29-Mar-14 lodine-131 3.17E-03 1.03E-02 6.00E-03 pCilm3 8S2 SW Site Boundary(34644801 0)- AC 5-Apr-14 lodine-131
-1.51 E-03 1.87E-02 1.14E-02 pCilm3 8S2 SW Site Boundary(34688301 0) - AC 12-Apr-14 lodine-131 5.45E-03 1.23E-02 6.98E-03 pCilm3 8S2 SW Site Boundary(347387007) - AC 19-Apr-14 lodine-131
-4.09E-04 1.00E-02 5.96E-03 pCi/m3 8S2 SW Site Boundary(34786201 0)- AC 26-Apr-14 lodine-131 2.05E-03 1.05E-02 6.02E-03 pCilm3 8S2 SW Site Boundary(34834201 0) - AC 3-May-14 lodine-131 2.62E-04 7.97E-03 4.67E-03 pCi/m3 8S2 SW Site Boundary(34877901 0) - AC 10-May-14 lodine-131
-2.60E-03 1.30E-02 8.48E-03 pCilm3 8S2 SW Site Boundary(34926201 0)- AC 17-May-14 lodine-131
___ I --
2.27E-02 3.11E-02 1.95E-02 pCi/m3 Page 40 of 92
2014 DCPP REMP Analysis Results Appendix C 8S2 SW Site Boundary(34956301 0) - AC 24-May-14 lodine-131
-7.20E-04 1.1 OE-02 6.78E-03 pCi/m3 8S2 SW Site Boundary(35005201 0) - AC 31-May-14 lodine-131
-3.50E-03 1.47E-02 9.25E-03 pCi/m3 8S2 SW Site Boundary(35045501 0) - AC 7-Jun-14 lodine-131
-1.73E-03 1.25E-02 7.59E-03 pCi/m3 8S2 SW Site Boundary(35098601 0) - AC 14-Jun-14 lodine-131 4.09E-03 1.10E-02 6.25E-03 pCi/m3 8S2 SW Site Boundary(3514330 1 0) - AC 21-Jun-14 lodine-131 1.06E-03 1.78E-02 1.04E-02 pCi/m3 8S2 SW Site Boundary(35178901 0)- AC 28-Jun-14 lodine-131 4.35E-03 1.59E-02 8.98E-03 pCi/m3 8S2 SW Site Boundary(35236801 0) - AC 5-Jul-14 lodine-131
-6.20E-03 5.56E-03 5.58E-03 pCi/m3 8S2 SW Site Boundary(352849009) - AC 12-Jul-14 lodine-131 3.53E-03 9.88E-03 5.42E-03 pCi/m3 8S2 SW Site Boundary(35339901 0) - AC 19-Jul-14 lodine-131 2.54E-03 1.83E-02 1.07E-02 pCi/m3 8S2 SW Site Boundary(35378601 0)- AC 26-Jul-14 lodine-131
-1.76E-03 9.28E-03 6.03E-03 pCi/m3 8S2 SW Site Boundary(35427201 0) - AC 2-Aug-14 lodine-131 1.64E-03 9.09E-03 5.84E-03 pCi/m3 8S2 SW Site Boundary(35468901 0) - AC 9-Aug-14 lodine-131
-4.09E-03 7.79E-03 5.40E-03 pCi/m3 8S2 SW Site Boundary(355193010) - AC 16-Aug-14 lodine-131
-2.88E-03 1.18E-02 7.61 E-03 pCi/m3 8S2 SW Site Boundary(35565001 0)- AC 23-Aug-14 lodine-131 5.39E-03 2.63E-02 1.52E-02 pCi/m3 8S2 SW Site Boundary(35601301 0) - AC 30-Aug-14 lodine-131 1.05E-03 9.05E-03 5.30E-03 pCi/m3 8S2 SW Site Boundary(35662901 0) - AC 6-Sep-14 lodine-131
-4.65E-03 1.34E-02 8.81 E-03 pCi/m3 8S2 SW Site Boundary(35700301 0) - AC 13-Sep-14 lodine-131
-1.41 E-05 9.79E-03 5.85E-03 pCi/m3 8S2 SW Site Boundary(357 44101 0) - AC 20-Sep-14 lodine-131
-8.50E-04 9.30E-03 5.64E-03 pCi/m3 8S2 SW Site Boundary(357901 01 0)- AC 27-Sep-14 lodine-131
-3.92E-03 1.38E-02 9.32E-03 pCi/m3 8S2 SW Site Boundary(35865901 0)- AC 4-0ct-14 lodine-131
-5.96E-04 8.55E-03 5.16E-03 pCi/m3 8S2 SW Site Boundary(35917201 0) - AC 11-0ct-14 lodine-131 5.06E-03 1.19E-02 7.06E-03 pCi/m3 8S2 SW Site Boundary(35968601 0) - AC 18-0ct-14 lodine-131 7.78E-03 1.18E-02 6.89E-03 pCi/m3 8S2 SW Site Boundary(36017301 0) - AC 25-0ct-14 lodine-131
-8.15E-04 1.49E-02 9.25E-03 pCi/m3 8S2 SW Site Boundary(36070401 0) - AC 1-Nov-14 lodine-131
-9.28E-03 1.60E-02 1.19E-02 pCi/m3 8S2 SW Site Boundary(36118401 0) - AC 8-Nov-14 lodine-131
-2.78E-03 1.03E-02 6.74E-03 pCi/m3 8S2 SW Site Boundary(36168701 0) - AC 15-Nov-14 lodine-131 2.17E-03 1.03E-02 5.92E-03 pCi/m3 8S2 SW Site Boundary(36207701 0) - AC 22-Nov-14 lodine-131 1.27E-02 2.13E-02 9.29E-03 pCi/m3 8S2 SW Site Boundary(36229301 0) - AC 28-Nov-14 lodine-131
-2.86E-03 1.42E-02 8.89E-03 pCi/m3 8S2 SW Site Boundary(36289301 0)- AC 6-Dec-14 lodine-131
-4.16E-03 8.94E-03 6.30E-03 pCi/m3 8S2 SW Site Boundary(36352301 0) - AC 13-Dec-14 lodine-131 5.22E-03 1.43E-02 8.26E-03 pCi/m3 8S2 SW Site Boundary(36377901 0) - AC 20-Dec-14 lodine-131
-6.84E-03 1.45E-02 9.73E-03 pCi/m3 8S2 SW Site Boundary(36394601 0) - AC 26-Dec-14 lodine-131
-1.64E-03 1.07E-02 6.75E-03 pCi/m3 s s2 sw site8oundary ~ Air Particulate- ------- --- -- - --------*-
. *-----~---- --- - ------
Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S2 SW Site Boundary(340937003) - AP 3-Jan-14 BETA 1.09E-01 1.04E-03 1.07E-02 pCi/m3 8S2 SW Site Boundary(341469003) - AP 11-Jan-14 BETA 4.03E-02 1.31 E-03 1.02E-02 pCi/m3 8S2 SW Site Boundary(341857003) - AP 18-Jan-14 BETA 7.83E-02 1.25E-03 1.21E-02 pCi/m3 8S2 SW Site Boundary(342138003)- AP 25-Jan-14 BETA 9.04E-02 1.39E-03 1.36E-02 pCi/m3 8S2 SW Site Boundary(342582003) - AP 1-Feb-14 BETA 1.04E-02 1.33E-03 1.07E-02 pCi/m3 8S2 SW Site Boundary(343015003) - AP 8-Feb-14 BETA 1.76E-02 1.35E-03 9.86E-03 pCi/m3 I
8S2 SW Site Boundary(343355003) - AP 15-Feb-14 BETA 1.52E-02 1.38E-03 9.74E-03 pCi/m3 8S2 SW Site Boundary(343769003) - AP 22-Feb-14 BETA 2.27E-02 1.33E-03 1.05E-02 pCi/m3 8S2 SW Site Boundary(344077003) - AP 1-Mar-14 BETA 1.31E-02 1.35E-03 1.11 E-02 pCi/m3 8S2 SW Site Boundary(344522003)- AP 8-Mar-14 BETA 2.53E-02 1.28E-03 1.19E-02 pCi/m3 Page 41 of 92
2014 DCPP REMP Analysis Results Appendix C 8S2 SW Site Boundary(344947003)- AP 15-Mar-14 BETA 2.80E-02 1.34E-03 1.04E-02 pCilm3 8S2 SW Site Boundary(345381003)- AP 22-Mar-14 BETA 2.43E-02 1.36E-03 1.26E-02 pCi/m3 8S2 SW Site Boundary(345737003) - AP 29-Mar-14 BETA 1.02E-02 1.26E-03 9.34E-03 pCilm3 8S2 SW Site Boundary(346448003) - AP 5-Apr-14 BETA 2.40E-02 1.34E-03 9.46E-03 pCi!m3 8S2 SW Site Boundary(346883003) - AP 12-Apr-14 BETA 3.07E-02 1.31 E-03 1.01 E-02 pCilm3 8S2 SW Site Boundary(347387013) - AP 19-Apr-14 BETA 2.03E-02 1.39E-03 9.17E-03 pCilm3 8S2 SW Site Boundary(347862003) - AP 26-Apr-14 BETA 1.73E-02 1.45E-03 9.75E-03 pCilm3 8S2 SW Site Boundary(348342003) - AP 3-May-14 BETA 2.96E-02 1.44E-03 1.07E-02 pCilm3 8S2 SW Site Boundary(348779003) - AP 10-May-14 BETA 1.70E-02 1.55E-03 9.61 E-03 pCilm3 8S2 SW Site Boundary(349262003) - AP 17-May-14 BETA 1.98E-02 1.49E-03 1.13E-02 pCilm3 8S2 SW Site Boundary(349563003) - AP 24-May-14 BETA 1.07E-02 1.31 E-03 8.54E-03 pCilm3 8S2 SW Site Boundary(350052003) - AP 31-May-14 BETA 1.88E-02 1.31 E-03 1.12E-02 pCilm3 8S2 SW Site Boundary(350455003) - AP 7 -Jun-14 BETA 1.45E-02 1.80E-03 1.27E-02 pCilm3 8S2 SW Site Boundary(350986003) - AP 14-Jun-14 BETA 1.44E-02 1.18E-03 8.65E-03 pCi/m3 8S2 SW Site Boundary(351433003)- AP 21-Jun-14 BETA 1.07E-02 1.41 E-03 9.73E-03 pCi/m3 8S2 SW Site Boundary(351789003)- AP 28-Jun-14 BETA 5.12E-03 1.47E-03 1.12E-02 pCilm3 i
8S2 SW Site Boundary(352368003) - AP 5-Jul-14 BETA 1.33E-02 1.44E-03 8.83E-03 pCi/m3 8S2 SW Site Boundary(352849003) - AP 12-Jul-14 BETA 7.15E-03 1.33E-03 1.11 E-02 pCilm3 8S2 SW Site Boundary(353399003) - AP 19-Jul-14 BETA 1.76E-02 1.32E-03 1.13E-02 pCilm3 8S2 SW Site Boundary(353786003) - AP 26-Jul-14 BETA 1.63E-02 1.30E-03 1.14E-02 pCilm3 8S2 SW Site Boundary(354272003) - AP 2-Aug-14 BETA 1.47E-02 1.42E-03 9.95E-03 pCilm3 8S2 SW Site Boundary(354689003) - AP 9-Aug-14 BETA 1.41 E-02 1.37E-03 1.03E-02 pCilm3 8S2 SW Site Boundary(355193003)- AP 16-Aug-14 BETA 6.27E-03 1.42E-03 9.16E-03 pCi!m3 8S2 SW Site Boundary(355650003) - AP 23-Aug-14 BETA 1.88E-02 1.35E-03 1.01 E-02 pCi/m3 8S2 SW Site Boundary(356013003) - AP 30-Aug-14 BETA 1.73E-02 1.35E-03 1.07E-02 pCi/m3 8S2 SW Site Boundary(356629003) - AP 6-Sep-14 BETA 2.61 E-02 1.34E-03 1.05E-02 pCilm3 8S2 SW Site Boundary(357003003) - AP 13-Sep-14 BETA 5.22E-02 1.34E-03 1.09E-02 pCilm3 8S2 SW Site Boundary(357 441 003) - AP 20-Sep-14 BETA 2.39E-02 1.21 E-03 9.01 E-03 pCi/m3 8S2 SW Site Boundary(357901 003)- AP 27-Sep-14 BETA 2.07E-02 1.38E-03 1.03E-02 pCilm3 8S2 SW Site Boundary(358659003) - AP 4-0ct-14 BETA 6.01 E-02 1.30E-03 1.19E-02 pCilm3 8S2 SW Site Boundary(359172003)- AP 11-0ct-14 BETA 3.47E-02 1.44E-03 1.01 E-02 pCilm3 8S2 SW Site Boundary(359686003) - AP 18-0ct-14 BETA 1.47E-02 1.35E-03 9.98E-03 pCilm3 8S2 SW Site Boundary(360173003)- AP 25-0ct-14 BETA 1.92E-02 1.34E-03 1.12E-02 pCi/m3 8S2 SW Site Boundary(360704003) - AP 1-Nov-14 BETA 3.59E-02 1.37E-03 1.27E-02 pCilm3 8S2 SW Site Boundary(361184003) - AP 8-Nov-14 BETA 4.95E-02 1.41 E-03 1.17E-02 pCi!m3 8S2 SW Site Boundary(361687003) - AP 15-Nov-14 BETA 4.97E-02 1.38E-03 1.18E-02 pCi!m3 8S2 SW Site Boundary(362077003) - AP 22-Nov-14 BETA 1.79E-02 1.68E-03 1.28E-02 pCilm3 8S2 SW Site Boundary(362293003) - AP 28-Nov-14 BETA 4.61 E-02 1.46E-03 1.09E-02 pCilm3 8S2 SW Site Boundary(362893003) - AP 6-Dec-14 BETA 1.68E-02 1.12E-03 9.12E-03 pCilm3 8S2 SW Site Boundary(363523003) - AP 13-Dec-14 BETA 1.29E-02 1.29E-03 9.26E-03 pCilm3 8S2 SW Site Boundary(363779003) - AP 20-Dec-14 BETA 6.42E-03 1.66E-03 1.31E-02 pCi/m3 8S2 SW Site Boundary(363946003) - AP 26-Dec-14 BETA 1.40E-02 1.37E-03 1.11 E-02 pCi/m3 8S2 SW Site Boundary(347208003) - AP 14-Feb-14 Beryllium-?
1.13E-01 1.14E-02 2.09E-02 pCi/m3 8S2 SW Site Boundary(353206003) - AP 17-May-14 Beryllium-?
8.56E-02 8.22E-03 1.64E-02 pCilm3 8S2 SW SI!e Boundary(359403003) - AP 16-Aug-14 Beryllium-?
1.10E-01 9.28E-03 1.98E-02 pCilm3 Page 42 of 92
2014 DCPP REMP Analysis Results Appendix C 8S2 SW Site Boundary(365208003) - AP 15-Nov-14 Beryllium-?
8.95E-02 1.04E-02 1.84E-02 pCilm3 8S2 SW Site Boundary(347208003)- AP 14-Feb-14 Cesium-134 1.31 E-04 6.29E-04 3.59E-04 pCi/m3 8S2 SW Site Boundary(353206003) - AP 17-May-14 Cesium-134
-2.80E-05 5.58E-04 3.31 E-04 pCi/m3 8S2 SW Site Boundary(359403003) - AP 16-Aug-14 Cesium-134
-2.92E-04 6.88E-04 4.92E-04 pCilm3 8S2 SW Site Boundary(365208003) - AP 15-Nov-14 Cesium-134
-1.37E-04 4.63E-04 3.05E-04 pCi/m3 8S2 SW Site Boundary(347208003)- AP 14-Feb-14 Cesium-137 5.22E-05 5.10E-04 2.93E-04 pCi/m3 8S2 SW Site Boundary(353206003) - AP 17-May-14 Cesium-137
-4.75E-05 5.34E-04 3.35E-04 pCilm3 8S2 SW Site Boundary(359403003) - AP 16-Aug-14 Cesium-137 3.37E-05 6.68E-04 3.92E-04 pCilm3 8S2 SW Site Boundary(365208003)- AP 15-Nov-14 Cesium-137
-9.12E-05 4.83E-04 3.04E-04 pCilm3 8S3 DCSF96-1 -Groundwater Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units 8S3 DCSF96-1(345131003)- GW 17-Mar-14 BETA 5.64E+OO 1.72E+OO 1.57E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 BETA 2.43E+OO 1.07E+OO 8.91 E-01 pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 BETA 3.87E+OO 1.37E+OO 1.17E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 BETA 6.90E+OO 1.39E+OO 1.57E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Barium-140 4.27E-01 3.14E+OO 2.12E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Barium-140 1.32E+OO 3.08E+OO 1.80E+OO pCi/L 8S3 DCSF96-1(355458002)- GW 20-Aug-14 Barium-140
-1.08E+OO 3.29E+OO 2.14E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Barium-140 2.79E-01 2.70E+OO 1.60E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Cesium-134 4.42E-01 2.02E+OO 2.19E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Cesium-134 7.98E-02 1.77E+OO 1.03E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Cesium-134
-5.48E-01 2.11 E+OO 1.29E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Cesium-134
-3.56E-01 1.79E+OO 1.10E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Cesium-137 9.93E-01 1.91 E+OO 1.20E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Cesium-137 2.20E-01 1.69E+OO 1.17E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Cesium-137 1.02E+OO 2.09E+OO 1.29E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Cesium-137 2.33E-01 1.73E+OO 1.01 E+OO pCi/L 8S3 DCSF96-1 (345131 003)- GW 17-Mar-14 Cobalt-58 4.97E-01 1.85E+OO 1.08E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Cobalt-58
-2.65E-01 1.52E+OO 9.17E-01 pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Cobalt-58
-3.40E-01 1.96E+OO 1.18E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Cobalt-58 1.04E+OO 1.63E+OO 1.27E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Cobalt-60
-1.27E-01 1.72E+OO 1.03E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Cobalt-60
-4.68E-01 1.60E+OO 1.00E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Cobalt-60
-1.56E+OO 1.93E+OO 1.68E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Cobalt-60
-6.54E-01 1.56E+OO 1.07E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 lodine-131 1.79E+OO 4.03E+OO 2.46E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 lodine-131
-3.92E-01 3.16E+OO 1.87E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 lodine-131 6.84E-01 3.54E+OO 2.15E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 lodine-131
-1.24E-01 3.15E+OO 1.89E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Iron-55
-1.95E+01 8.29E+01 6.03E+01 pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Iron-55 1.26E+02 1.41 E+02 1.06E+02 pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Iron-55 9.03E+OO 7.08E+01 4.99E+01 pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Iron-55 4.31 E+01 7.73E+01 5.79E+01 pCi/L 8S3DCSF96-1(345131003)- GW 17-Mar-14 Iron-59
-2.51 E+OO 3.11 E+OO 2.44E+OO pCi/L Page 43 of 92
2014 DCPP REMP Analysis Results Appendix C 8S3 DCSF96-1 (349032002)- GW 13-May-14 Iron-59 1.61 E+OO 3.41 E+OO 2.06E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Iron-59 6.12E-01 4.24E+OO 2.52E+OO pCi!L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Iron-59
-1.36E+OO 3.18E+OO 2.05E+OO pCi!L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Lanthanum-140 4.27E-01 3.14E+OO 2.12E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Lanthanum-140 1.32E+OO 3.08E+OO 1.80E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Lanthanum-140
-1.08E+OO 3.29E+OO 2.14E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Lanthanum-140 2.79E-01 2.70E+OO 1.60E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Manganese-54
-5.63E-01 1.75E+OO 1.28E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Manganese-54
-5.56E-02 1.59E+OO 1.08E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Manganese-54
-4.06E-01 1.82E+OO 1.11 E+OO pCi/L 8S3 DCSF96-1 (360258003) - GW 27-0ct-14 Manganese-54 4.34E-01 1.69E+OO 1.01 E+OO pCi!L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Nickel-63 7.23E+OO 3.43E+01 2.09E+01 pCi!L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Nickel-63 8.45E+OO 3.07E+01 1.87E+01 pCi/L 8S3 DCSF96-1(355458002)- GW 20-Aug-14 Nickel-63 2.83E+01 3.81 E+01 2.44E+01 pCi!L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Nickel-63 5.66E+OO 3.16E+01 1.91 E+01 pCi/L 8S3 DCSF96-1 (345131 003)- GW 17-Mar-14 Niobium-95 3.63E-01 1.85E+OO 1.08E+OO pCi/L 8S3 DCSF96-1(349032002)- GW 13-May-14 Niobium-95 8.08E-01 1.78E+OO 1.06E+OO pCi!L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Niobium-95 1.48E+OO 2.20E+OO 1.38E+OO pCi/L 8S3 DCSF96-1(360258003)- GW 27-0ct-14 Niobium-95
-2.60E-01 1.68E+OO 1.02E+OO pCi!L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Total Strontium 1.23E-01 2.44E-01 1.52E-01 pCi!L 8S3 DCSF96-1 (349032002) - GW 13-May-14 Total Strontium 4.79E-02 1.64E-01 9.96E-02 pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Total Strontium
-6.89E-02 1.39E-01 7.94E-02 pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Total Strontium
-1.22E-01 4.04E-01 2.36E-01 pCi!L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Tritium 5.11 E+OO 2.41 E+02 1.44E+02 pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Tritium 9.25E+01 2.11 E+02 1.33E+02 pCi!L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Tritium
-9.16E+01 2.91 E+02 1.69E+02 pCi!L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Tritium 4.34E+01 2.54E+02 1.54E+02 pCi/L 8S3 DCSF96-1 (345131 003)- GW 17-Mar-14 Zinc-65
-2.03E-02 3.79E+OO 2.30E+OO pCi!L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Zinc-65
-1.75E-02 3.35E+OO 2.02E+OO pCi/L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Zinc-65 1.22E+OO 4.19E+OO 2.49E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Zinc-65
-3.21 E-01 3.33E+OO 2.29E+OO pCi/L 8S3 DCSF96-1(345131003)- GW 17-Mar-14 Zirconium-95 4.51 E-01 3.20E+OO 1.87E+OO pCi/L 8S3 DCSF96-1 (349032002)- GW 13-May-14 Zirconium-95
-2.94E-01 2.80E+OO 1.66E+OO pCi!L 8S3 DCSF96-1 (355458002)- GW 20-Aug-14 Zirconium-95 3.17E-01 3.53E+OO 2.05E+OO pCi/L 8S3 DCSF96-1 (360258003)- GW 27-0ct-14 Zirconium-95
-2.02E-01 2.93E+OO 1.76E+OO pCi/L AVA Avila Beach-Beach Sand Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units AVA Avila Beach(343203003)- SO 11-Feb-14 Barium-140 1.59E+01 1.15E+02 6.31 E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Barium-140
-1.95E+01 1.01 E+02 6.46E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Barium-140
-2.25E+01 8.58E+01 5.73E+01 pCilkg AVA Avila Beach(343203003)- SO 11-Feb-14 Bismuth-214 4.03E+02 8.40E+01 1.18E+02 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Cesium-134 1.00E+01 6.16E+01 3.38E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Cesium-134 2.63E+01 1.06E+02 6.14E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Cesium-134 2.23E+01 6.86E+01 3.71 E+01 pCilkg Page 44 of 92
2014 DCPP REMP Analysis Results Appendix C AVA Avila Beach(343203003)- SO 11-Feb-14 Cesium-137 5.50E-01 5.37E+01 3.17E+01 pCilkg AVA Avila Beach(345659001)- SO 27-Mar-14 Cesium-137 5.22E+OO 9.52E+01 5.42E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Cesium-137 3.82E+01 3.82E+01 3.96E+01 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Cobalt-58
-3.81 E+01 3.76E+01 3.44E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Cobalt-58 8.83E+OO 8.83E+01 5.08E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Cobalt-58 1.12E+01 6.31 E+01 3.46E+01 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Cobalt-60
-1.36E+01 5.66E+01 3.78E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Cobalt-60 3.77E+OO 8.26E+01 4.85E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Cobalt-60
-1.75E+01 4.46E+01 3.13E+01 pCi!kg AVA Avila Beach(343203003)- SO 11-Feb-14 Iron-55
-9.46E+03 1.68E+04 1.14E+04 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Iron-55
-1.74E+03 1.04E+04 7.51 E+03 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Iron-55 1.08E+03 1.16E+04 7.87E+03 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Iron-59 6.89E+01 1.64E+02 1.01 E+02 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Iron-59 7.14E+01 1.97E+02 8.77E+01 pCi/kg AVA Avila Beach(35691 0002)- SO 11-Sep-14 Iron-59 1.53E+01 1.22E+02 6.90E+01 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Lanthanum-140 1.59E+01 1.15E+02 6.31 E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Lanthanum-140
-1.95E+01 1.01 E+02 6.46E+01 pCilkg AVA Avila Beach(356910002)- SO 11-Sep-14 Lanthanum-140
-2.25E+01 8.58E+01 5.73E+01 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Lead-214 4.77E+02 8.23E+01 1.37E+02 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Manganese-54
-2.37E+01 5.80E+01 3.82E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Manganese-54
-5.53E+01 7.1 OE+01 6.46E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Manganese-54 8.45E+OO 5.55E+01 3.05E+01 pCi!kg AVA Avila Beach(343203003)- SO 11-Feb-14 Nickel-63
-6.24E+02 2.30E+03 1.34E+03 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Nickel-63 1.60E+02 2.56E+03 1.53E+03 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Nickel-63 3.34E+02 1.99E+03 1.21 E+03 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Niobium-95 2.57E+01 7.03E+01 5.21 E+01 pCilkg AVA Avila Beach(345659001)- SO 27-Mar-14 Niobium-95
-4.45E+01 8.57E+01 5.82E+01 pCilkg AVA Avila Beach(356910002)- SO 11-Sep-14 Niobium-95 9.86E+OO 6.01 E+01 3.72E+01 pCilkg AVA Avila Beach(343203003)- SO 11-Feb-14 Potassium-40 1.27E+04 O.OOE+OO 1.86E+03 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Potassium-40 1.41E+04 8.16E+02 1.94E+03 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Potassium-40 1.24E+04 2.57E+02 1.77E+03 pCilkg AVA Avila Beach(343203003)- SO 11-Feb-14 Total Strontium 1.41 E+02 7.33E+02 4.61 E+02 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Total Strontium
-2.41 E+03 1.24E+03 3.92E+02 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Total Strontium
-1.37E+02 6.61 E+02 3.69E+02 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Zinc-65 2.96E+01 1.28E+02 8.02E+01 pCi!kg AVA Avila Beach(345659001)- SO 27-Mar-14 Zinc-65 1.04E+02 2.19E+02 9.96E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Zinc-65
-2.82E+01 1.31 E+02 8.35E+01 pCi/kg AVA Avila Beach(343203003)- SO 11-Feb-14 Zirconium-95 3.48E+01 1.08E+02 5.79E+01 pCi/kg AVA Avila Beach(345659001)- SO 27-Mar-14 Zirconium-95 5.30E+OO 1.64E+02 9.49E+01 pCi/kg AVA Avila Beach(356910002)- SO 11-Sep-14 Zirconium-95
5.40E+01 1.03E+02 5.50E+01 pCi/kg Page 45 of 92
2014 DCPP REMP Analysis Results Appendix C BCM Blanchard Cow Meat Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Cesium-134 3.01 E+OO 4.75E+OO 3.62E+OO pCi/kg BCM Blanchard Cow Meat(350522001) - MT 5-Jun-14 Cesium-134
-9.35E-01 3.70E+OO 2.26E+OO pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Cesium-134
-2.69E+OO 5.02E+OO 4.36E+OO pCi/kg BCM Blanchard Cow Meat(360804001) - MT 4-Nov-14 Cesium-134
-8.35E-01 5.26E+OO 3.59E+OO pCi/kg BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Cesium-137 2.43E+OO 4.29E+OO 2.51 E+OO pCi/kg BCM Blanchard Cow Meat(350522001)- MT 5-Jun-14 Cesium-137 4.36E-01 3.73E+OO 2.75E+OO pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Cesium-137 1.91 E+OO 4.92E+OO 2.96E+OO pCi/kg BCM Blanchard Cow Meat(360804001) - MT 4-Nov-14 Cesium-137
-4.80E+OO 4.53E+OO 4.67E+OO pCi/kg I
BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Cobalt-58 1.11E-01 4.39E+OO 2.64E+OO pCi/kg BCM Blanchard Cow Meat(350522001) - MT 5-Jun-14 Cobalt-58
-1.13E+OO 3.69E+OO 3.08E+OO pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Cobalt-58 1.60E-01 4.61E+OO 2.78E+OO pCi/kg BCM Blanchard Cow Meat(360804001)- MT 4-Nov-14 Cobalt-58
-4.81 E-01 4.62E+OO 2.81 E+OO pCi/kg BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Cobalt-60 1.83E+OO 4.81 E+OO 2.82E+OO pCi/kg BCM Blanchard Cow Meat(350522001)- MT 5-Jun-14 Cobalt-60
-1.64E+OO 3.67E+OO 2.47E+OO pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Cobalt-60
-7.16E-01 5.24E+OO 3.23E+OO pCi/kg BCM Blanchard Cow Meat(360804001) - MT 4-Nov-14 Cobalt-60
-1.71 E+OO 5.65E+OO 3.66E+OO pCi/kg BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 lodine-131
-9.94E-01 5.56E+OO 3.32E+OO pCi/kg BCM Blanchard Cow Meat(350522001)- MT 5-Jun-14 lodine-131 9.62E-01 6.76E+OO 3.99E+OO pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 lodine-131 2.35E+OO 5.47E+OO 3.35E+OO pCi/kg BCM Blanchard Cow Meat(360804001) - MT 4-Nov-14 lodine-131
-1.08E+OO 8.88E+OO 5.46E+OO pCi/kg BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Potassium-40 2.50E+03 3.89E+01 2.68E+02 pCi/kg BCM Blanchard Cow Meat(350522001)- MT 5-Jun-14 Potassium-40 2.51 E+03 3.03E+01 2.54E+02 pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Potassium-40 2.81 E+03 4.1 OE+01 2.70E+02 pCi/kg BCM Blanchard Cow Meat(360804001)- MT 4-Nov-14 Potassium-40 2.96E+03 4.66E+01 2.88E+02 pCi/kg BCM Blanchard Cow Meat(344644003) - MT 13-Mar-14 Total Strontium
-3.85E+01 5.37E+01 3.03E+01 pCi/kg BCM Blanchard Cow Meat(350522001)- MT 5-Jun-14 Total Strontium 1.54E+01 4.87E+01 3.00E+01 pCi/kg BCM Blanchard Cow Meat(355617001)- MT 26-Aug-14 Total Strontium
-2.32E+OO 4.58E+01 2.72E+01 pCi/kg BCM Blanchard Cow Meat(360804001) - MT 4-Nov-14 Total Strontium
-2.75E+01 4.49E+01 2.60E+01 pCi/kg CBA Cambria Moonstone Beach - Beach Sand Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units CBA Cambria Moonstone Beach(343203006) - SO 11-Feb-14 Actinium-228 5.66E+02 1.28E+02 1.94E+02 pCi/kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Barium-140
-8.53E+01 4.74E+01 7.35E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SO 11-Sep-14 Barium-140
-2.15E+01 4.93E+01 3.69E+01 pCi/kg CBA Cambria Moonstone Beach(343203006)- SO 11-Feb-14 Bismuth-214 4.13E+02 8.63E+01 1.33E+02 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SO 11-Sep-14 Bismuth-214 4.60E+02 8.94E+01 1.25E+02 pCi/kg CBA Cambria Moonstone Beach(343203006) - SO 11-Feb-14 Cesium-134 7.30E+01 7.56E+01 5.94E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SO 11-Sep-14 Cesium-134 1.79E+01 5.69E+01 3.07E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SO 11-Feb-14 Cesium-137 4.29E+01 4.29E+01 3.16E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SO 11-Sep-14 Cesium-137 4.40E+01 4.40E+01 2.76E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Cobalt-58
-1.97E+01 4.30E+01 3.06E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Cobalt-58
-1.50E+01 3.25E+01 2.62E+01 pCi/kg Page 46 of 92
2014 DCPP REMP Analysis Results Appendix C CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Cobalt-60 2.40E+OO 5.79E+01 3.36E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Cobalt-60
-4.46E+OO 4.79E+01 2.95E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Iron-55
-1.12E+04 1.35E+04 9.21E+03 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Iron-55
-6.51 E+03 8.59E+03 5.55E+03 pCi!kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Iron-59 4.78E+01 1.16E+02 5.11E+01 pCi!kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Iron-59
-5.00E+01 6.38E+01 5.42E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Lanthanum-140
-8.53E+01 4.74E+01 7.35E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Lanthanum-140
-2.15E+01 4.93E+01 3.69E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Lead-212 3.90E+02 8.77E+01 1.03E+02 pCi!kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Lead-212 4.64E+02 6.73E+01 9.85E+01 pCi/kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Lead-214 4.08E+02 9.47E+01 1.56E+02 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Lead-214 6.70E+02 2.10E+02 1.37E+02 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Manganese-54
-3.23E+01 3.50E+01 3.14E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Manganese-54
-7.56E+OO 4.62E+01 2.73E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Nickel-63
-8.1 OE+02 2.03E+03 1.17E+03 pCi!kg CBA Cambria Moonstone Beach(35691 0005) - SD 11-Sep-14 Nickel-63 4.61 E+02 2.14E+03 1.30E+03 pCi/kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Niobium-95
-4.12E+OO 4.94E+01 2.93E+01 pCi/kg CBA Cambria Moonstone Beach(35691 0005) - SD 11-Sep-14 Niobium-95 5.37E+01 5.96E+01 4.60E+01 pCi/kg CBA Cambria Moonstone Beach(343203006) - SD 11-Feb-14 Potassium-40 5.02E+03 3.55E+02 9.86E+02 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Thallium-208 1.76E+02 4.35E+01 6.34E+01 pCi!kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Total Strontium
-2.70E+02 6.45E+02 3.35E+02 pCi/kg CBA Cambria Moonstone Beach(35691 0005)- SD 11-Sep-14 Total Strontium
-2.15E+02 1.08E+03 6.20E+02 pCi/kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Zinc-65 5.29E+OO 1.14E+02 7.48E+01 pCi/kg CBA Cambria Moonstone Beach(356910005)- SD 11-Sep-14 Zinc-65
-2.18E+01 8.94E+01 6.75E+01 pCi/kg CBA Cambria Moonstone Beach(343203006)- SD 11-Feb-14 Zirconium-95
-1.50E+01 7.33E+01 4.61 E+01 pCi!kg CBA Cambria Moonstone Beach(356910005)- SD 11-Sep-14 Zirconium-95
-2.22E+01 6.56E+01 5.15E+01 pCi!kg CCM Control Location Cow Meat (Hearst Ranch or Northern CA)
Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units CCM Control Cow Meat(343090002) - MT 12-Feb-14 Cesium-134
-8.25E-01 5.13E+OO 3.08E+OO pCi/kg CCM Control Cow Meat(346801 003) - MT 8-Apr-14 Cesium-134 1.93E+OO 4.49E+OO 2.66E+OO pCi/kg CCM Control Cow Meat(354260001)- MT 4-Aug-14 Cesium-134 1.75E+OO 4.96E+OO 3.46E+OO pCi/kg CCM Control Cow Meat(360804004) - MT 4-Nov-14 Cesium-134
-3.51 E-01 4.92E+OO 3.24E+OO pCi!kg CCM Control Cow Meat(343090002) - MT 12-Feb-14 Cesium-137 2.26E+OO 4.76E+OO 2.81 E+OO pCilkg CCM Control Cow Meat(346801 003) - MT 8-Apr-14 Cesium-137
-1.37E+OO 3.92E+OO 2.75E+OO pCilkg CCM Control Cow Meat(354260001)- MT 4-Aug-14 Cesium-137
-2.22E+OO 4.26E+OO 3.32E+OO pCi/kg CCM Control Cow Meat(360804004) - MT 4-Nov-14 Cesium-137 3.87E+OO 4.19E+OO 3.15E+OO pCi/kg CCM Control Cow Meat(343090002) - MT 12-Feb-14 Cobalt-58
-7.84E-01 4.45E+OO 2.69E+OO pCi/kg CCM Control Cow Meat(346801 003) - MT 8-Apr-14 Cobalt-58
-7.76E-01 3.63E+OO 2.23E+OO pCi/kg CCM Control Cow Meat(354260001)- MT 4-Aug-14 Cobalt-58
-8.32E-01 4.55E+OO 3.20E+OO pCi/kg CCM Control Cow Meat(360804004)- MT 4-Nov-14 Cobalt-58 1.31 E+OO 4.62E+OO 2.70E+OO pCi/kg CCM Control Cow Meat(343090002) - MT 12-Feb-14 Cobalt-60 3.78E+OO 6.10E+OO 3.74E+OO pCi/kg CCM Control Cow Meat(346801 003)- MT 8-Apr-14 Cobalt-60 6.88E-01 3.93E+OO 2.25E+OO pCi/kg CCM Control Cow Meat(354260001)- MT 4-Aug-14 Cobalt-60 4.96E-01 5.33E+OO 3.19E+OO pCi/kg CCM Control Cow Meat(360804004)- MT 4-Nov-14 Cobalt-60 1.01 E+OO 5.27E+OO 3.06E+OO pCi/kg Page 47 of 92
2014 DCPP REMP Analysis Results Appendix C CCM Control Cow Meat(343090002) - MT 12-Feb-14 lodine-131
-1.63E+OO 6.12E+OO 3.90E+OO pCi!kg CCM Control Cow Meat(346801 003)- MT 8-Apr-14 lodine-131
-4.73E-01 6.99E+OO 4.17E+OO pCilkg CCM Control Cow Meat(354260001)- MT 4-Aug-14 lodine-131
-2.62E+OO 5.77E+OO 3.75E+OO pCi/kg CCM Control Cow Meat(360804004)- MT 4-Nov-14 lodine-131
-2.15E+OO 8.19E+OO 5.22E+OO pCi/kg CCM Control Cow Meat(343090002) - MT 12-Feb-14 Potassium-40 2.98E+03 4.29E+01 3.05E+02 pCilkg CCM Control Cow Meat(346801 003)- MT 8-Apr-14 Potassium-40 2.27E+03 4.30E+01 2.33E+02 pCi!kg CCM Control Cow Meat(354260001)- MT 4-Aug-14 Potassium-40 2.82E+03 4.30E+01 2.74E+02 pCilkg CCM Control Cow Meat(360804004)- MT 4-Nov-14 Potassium-40 2.40E+03 4.39E+01 2.40E+02 pCi/kg CCM Control Cow Meat(343090002) - MT 12-Feb-14 Total Strontium 2.35E+01 2.95E+01 1.95E+01 pCilkg CCM Control Cow Meat(346801 003)- MT 8-Apr-14 Total Strontium 1.55E+01 3.90E+01 2.43E+01 pCilkg CCM Control Cow Meat(354260001) - MT 4-Aug-14 Total Strontium
-8.81 E+OO 3.53E+01 2.06E+01 pCilkg CCM Control Cow Meat(360804004)- MT 4-Nov-14 Total Strontium
-8.75E+OO 4.04E+01 2.38E+01 pCi!kg CY A Cayucos Beach - Beach Sand Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units CYA Cayucos Beach(343203005) - SO 11-Feb-14 Barium-140 2.99E+01 9.35E+01 5.09E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Barium-140 2.08E+OO 8.69E+01 4.96E+01 pCilkg CYA Cayucos Beach(343203005)- SO 11 -Feb-14 Bismuth-214 2.69E+02 8.08E+01 8.58E+01 pCi/kg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Cesium-134 1.76E+01 4.39E+01 2.45E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Cesium-134
-2.30E+01 9.22E+01 5.81 E+01 pCilkg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Cesium-137 2.64E+01 4.82E+01 2.75E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Cesium-137 9.51 E+OO 7.92E+01 4.39E+01 pCi/kg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Cobalt-58
-1.96E+OO 4.54E+01 2.66E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Cobalt-58 2.46E+01 9.16E+01 5.07E+01 pCilkg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Cobalt-60
-1.48E+01 3.57E+01 2.48E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Cobalt-60
-3.21 E+01 6.65E+01 5.79E+01 pCilkg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Iron-55
-1.13E+04 1.37E+04 9.28E+03 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Iron-55
-9.34E+02 1.00E+04 6.74E+03 pCi!kg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Iron-59
-5.29E+OO 8.80E+01 5.17E+01 pCi/kg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Iron-59 3.94E+OO.
1.52E+02 8.68E+01 pCi!kg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Lanthanum-140 2.99E+01 9.35E+01 5.09E+01 pCi/kg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Lanthanum-140 2.08E+OO 8.69E+01 4.96E+01 pCi/kg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Lead-212 2.95E+02 5.89E+01 8.08E+01 pCi/kg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Lead-212 3.77E+02 1.06E+02 1.14E+02 pCilkg CYA Cayucos Beach(343203005)..: SO 11-Feb-14 Manganese-54 1.29E+OO 3.78E+01 2.19E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Manganese-54
-1.75E+OO 6.23E+01 4.29E+01 pCilkg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Nickel-63 6.54E+01 2.22E+03 1.33E+03 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Nickel-63 3.25E+02 2.04E+03 1.23E+03 pCilkg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Niobium-95 2.21E+01 4.51 E+01 2.55E+01 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Niobium-95 3.36E+OO 7.81 E+01 4.47E+01 pCi/kg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Potassium-40 8.44E+03 2.97E+02 1.17E+03 pCi/kg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Potassium-40 8.95E+03 5.45E+02 1.71E+03 pCilkg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Total Strontium
-6.51 E+01 6.57E+02 3.79E+02 pCilkg CYA Cayucos Beach(356910004)- SO 11-Sep-14 Total Strontium
-9.34E+01 8.85E+02 5.15E+02 pCi/kg CYA Cayucos Beach(343203005)- SO 11-Feb-14 Zinc-65 2.71 E+01 8.60E+01 5.42E+01 pCi!kg Page 48 of 92
2014 DCPP REMP Analysis Results Appendix C CYA Cayucos Beach(356910004)- SO 11-Sep-14 Zinc-65
-3.11 E+01 1.61 E+02 1.00E+02 pCi/kg CYA Cayucos Beach(343203005) - SO 11-Feb-14 Zirconium-95
-1.13E+01 6.27E+01 3.82E+01 pCi/kg CYA Cayucos Beach(356910004)- SO_
11-Sep-14 Zirconium-95
-6.04E+OO 1.14E+02 6.72E+01 pCi/kg DCM Diablo Cove Marine -Aquatic Vegetation Algae Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(342255005) - AV Algae 28-Jan-14 Cesium-134 8.42E-01 1.16E+01 6.86E+OO pCi/kg DCM Diablo Cove Marine(349258006) - AV Algae 19-May-14 Cesium-134
-2.50E+OO 9.07E+OO 6.26E+OO pCi/kg DCM Diablo Cove Marine(353262002) - AV Algae 17-Jul-14 Cesium-134
-3.58E-01 7.74E+OO 4.58E+OO pCi/kg DCM Diablo Cove Marine(360799004) - AV Algae 4-Nov-14 Cesium-134 1.96E+OO 9.52E+OO 5.55E+OO pCi/kg DCM Diablo Cove Marine(342255005) - AV Algae 28-Jan-14 Cesium-137
-6.1 OE-01 1.15E+01 7.51 E+OO pCi/kg DCM Diablo Cove Marine(349258006) - AV Algae 19-May-14 Cesium-137 2.94E+OO 8.61 E+OO 5.63E+OO pCi/kg DCM Diablo Cove Marine(353262002) - AV Algae 17-Jul-14 Cesium-137 2.25E+OO 8.43E+OO 5.20E+OO pCi/kg DCM Diablo Cove Marine(360799004)- AV Algae 4-Nov-14 Cesium-137
-1.65E+OO 8.99E+OO 6.06E+OO pCi/kg DCM Diablo Cove Marine(342255005) - AV Algae 28-Jan-14 Cobalt-58 2.69E+OO 1.03E+01 6.02E+OO pCi/kg DCM Diablo Cove Marine(349258006) - AV Algae 19-May-14 Cobalt-58
-5.53E-01 8.18E+OO 5.62E+OO pCi/kg DCM Diablo Cove Marine(353262002) - AV Algae 17-Jul-14 Cobalt-58 1.25E+OO 8.16E+OO 5.37E+OO pCi/kg DCM Diablo Cove Marine(360799004)- AV Algae 4-Nov-14 Cobalt-58 1.11E+OO 9.10E+OO 5.35E+OO pCi/kg DCM Diablo Cove Marine(342255005) - AV Algae 28-Jan-14 Cobalt-60
-5.35E+OO 1.24E+01 8.14E+OO pCi/kg DCM Diablo Cove Marine(349258006) - AV Algae 19-May-14 Cobalt-60 2.63E+OO 9.62E+OO 5.53E+OO pCi/kg DCM Diablo Cove Marine(353262002) - AV Algae 17-Jul-14 Cobalt-60
-6.95E-01 7.76E+OO 4.97E+OO pCi/kg DCM Diablo Cove Marine(360799004) - AV Algae 4-Nov-14 Cobalt-60 3.62E+OO 1.14E+01 6.63E+OO pCi/kg DCM Diablo Cove Marine(349258006) - AV Algae 19-May-14 Potassium-40 2.67E+03 6.90E+01 3.22E+02 pCi/kg DCM Diablo Cove Marine(353262002) - AV Algae 17-Jul-14 Potassium-40 3.58E+03 6.95E+01 3.94E+02 pCi/kg DCM Diablo Cove Marine(360799004)- AV Algae 4-Nov-14 Potassium-40 3.83E+03 6.96E+01 4.15E+02 pCi/kg
~--
DCM Diablo Cove Marine -Aquatic Vegetation Kelp Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(342255006)- AV Kelp 27-Jan-14 Cesium-134 2.30E-01 1.22E+01 7.33E+OO pCi/kg DCM Diablo Cove Marine(346440001)- AV Kelp 7-Apr-14 Cesium-134
-3.39E+OO 1.49E+01 9.40E+OO pCilkg DCM Diablo Cove Marine(352953004)- AV Kelp 15-Jul-14 Cesium-134
-6.16E+OO 1.85E+01 1.30E+01 pCi/kg DCM Diablo Cove Marine(359262001) - AV Kelp 15-0ct-14 Cesium-134 4.32E-01 1.90E+01 1.34E+01 pCi/kg DCM Diablo Cove Marine(342255006) - AV Kelp 27-Jan-14 Cesium-137
-2.96E+OO 1.24E+01 7.92E+OO pCi/kg DCM Diablo Cove Marine(346440001)- AV Kelp 7-Apr-14 Cesium-137 3.98E+OO 1.53E+01 9.58E+OO pCi/kg DCM Diablo Cove Marine(352953004)- AV Kelp 15-Jul-14 Cesium-137 5.79E-01 1.63E+01 9.82E+OO pCi/kg DCM Diablo Cove Marine(359262001) - AV Kelp 15-0ct-14 Cesium-137 4.55E+OO 1.75E+01 1.03E+01 pCi/kg DCM Diablo Cove Marine(342255006) - AV Kelp 27-Jan-14 Cobalt-58
-9.79E-01 1.07E+01 6.54E+OO pCi/kg DCM Diablo Cove Marine(346440001) - AV Kelp 7-Apr-14 Cobalt-58
-1.96E+OO 1.27E+01 7.89E+OO pCi/kg DCM Diablo Cove Marine(352953004)- AV Kelp 15-Jul-14 Cobalt-58
-7.05E+OO 1.69E+01 1.09E+01 pCi/kg DCM Diablo Cove Marine(359262001) - AV Kelp 15-0ct-14 Cobalt-58 9.17E+OO 1.83E+01 1.28E+01 pCi/kg DCM Diablo Cove Marine(342255006) - AV Kelp 27-Jan-14 Cobalt-60
-4.82E+OO 1.25E+01 8.21E+OO pCi/kg DCM Diablo Cove Marine(346440001) - AV Kelp 7-Apr-14 Cobalt-60 9.74E+OO 1.71E+01 1.37E+01 pCi/kg DCM Diablo Cove Marine(352953004)- AV Kelp 15-Jul-14 Cobalt-60
-2.98E+OO 2.09E+01 1.49E+01 pCi/kg I
I DCM Diablo Cove Marine(359262001) - AV Kelp 15-0ct-14 Cobalt-60
-5.44E+OO 2.13E+01 1.35E+01 pCi/kg DCM Diablo Cove Marine(342255006) - AV Kelp 27-Jan-14 Potassium-40 1.45E+04 8.14E+01 1.36E+03 pCi/kg_
Page 49 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(346440001) - AV Kelp 7-Apr-14 Potassium-40 1.16E+04 1.20E+02 1.12E+03 pCi/kg DCM Diablo Cove Marine(352953004)- AV Kelp 15-Jul-14 Potassium-40 1.71 E+04 1.14E+02 1.67E+03 pCi/kg DCM Diablo Cove Marine(359262001) - AV Kelp 15-0ct-14 Potassium-40 1.54E+04 1.48E+02 1.45E+03 pCi/kg DCM Diablo Cove Marine - Fish Perch Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(343132001)- FH Perch 17 -Jan-14 Cesium-134
-5.41 E-01 5.19E+OO 3.09E+OO pCilkg DCM Diablo Cove Marine(349673001) - FH Perch 23-May-14 Cesium-134
-1.43E+OO 5.92E+OO 3.58E+OO pCi/kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Cesium-134
-1.15E+OO 4.01E+OO 2.46E+OO pCi/kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Cesium-134
-6.63E-01 5.41 E+OO 4.80E+OO pCilkg DCM Diablo Cove Marine(343132001)- FH Perch 17-Jan-14 Cesium-137 2.42E+OO 5.24E+OO 3.23E+OO pCi/kg DCM Diablo Cove Marine(349673001)- FH Perch 23-May-14 Cesium-137 7.40E+OO 5.04E+OO 4.79E+OO pCi/kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Cesium-137 2.48E+OO 3.72E+OO 3.21 E+OO pCilkg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Cesium-137 8.92E+OO 4.52E+OO 5.15E+OO pCi/kg DCM Diablo Cove Marine(343132001)- FH Perch 17 -Jan-14 Cobalt-58 9.43E-01 6.09E+OO 3.54E+OO pCilkg DCM Diablo Cove Marine(349673001) - FH Perch 23-May-14 Cobalt-58
-6.05E-01 5.52E+OO 3.26E+OO pCi/kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Cobalt-58
-5.74E-01 3.67E+OO 2.19E+OO pCilkg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Cobalt-58 6.48E-01 5.02E+OO 2.98E+OO pCi/kg DCM Diablo Cove Marine(343132001)- FH Perch 17-Jan-14 Cobalt-60
-3.41 E+OO 5.04E+OO 3.62E+OO pCilkg DCM Diablo Cove Marine(349673001) - FH Perch 23-May-14 Cobalt-60 8.26E-01 5.41 E+OO 3.21 E+OO pCi!kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Cobalt-60 1.81E-01 4.41 E+OO 3.31 E+OO pCi!kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Cobalt-60 4.13E+OO 6.18E+OO 4.10E+OO pCi/kg DCM Diablo Cove Marine(343132001)- FH Perch 17 -Jan-14 Iron-59
-7.23E-01 1.86E+01 1.12E+01 pCi/kg DCM Diablo Cove Marine(349673001)- FH Perch 23-:May-14 Iron-59 1.31 E+OO 1.25E+01 7.40E+OO pCi/kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Iron-59 1.46E-01 9.20E+OO 5.45E+OO pCi/kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Iron-59
-8.99E-01 1.19E+01 6.99E+OO pCi!kg DCM Diablo Cove Marine(343132001)- FH Perch 17-Jan-14 Manganese-54
-5.78E-01 5.29E+OO 3.16E+OO pCi/kg DCM Diablo Cove Marine(349673001)- FH Perch 23-May-14 Manganese-54
-5.55E-01 5.54E+OO 3.28E+OO pCi/kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Manganese-54
-7.68E-01 3.61 E+OO 2.18E+OO pCi/kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Manganese-54 1.09E-02 4.85E+OO 3.28E+OO pCi/kg DCM Diablo Cove Marine(34313200 1) - FH Perch 17 -Jan-14 Potassium-40 3.76E+03 5.00E+01 3.71E+02 pCilkg DCM Diablo Cove Marine(349673001)- FH Perch 23-May-14 Potassium-40 3.60E+03 4.45E+01 3.46E+02 pCi/kg DCM Diablo Cove Marine(355525008)- FH Perch 21-Aug-14 Potassium-40 3.35E+03 3.54E+01 3.12E+02 pCi/kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Potassium-40 3.80E+03 4.41 E+01 3.62E+02 pCi/kg DCM Diablo Cove Marine(343132001)- FH Perch 17-Jan-14 Zinc-65 3.88E+OO 1.48E+01 8.84E+OO pCi/kg DCM Diablo Cove Marine(349673001) - FH Perch 23-May-14 Zinc-65 2.69E+OO 1.25E+01 8.50E+OO pCi!kg DCM Diablo Cove Marine(355525008) - FH Perch 21-Aug-14 Zinc-65 9.90E-02 9.22E+OO 6.31 E+OO pCi/kg DCM Diablo Cove Marine(361289001)- FH Perch 11-Nov-14 Zinc-65 7.91 E+OO 1.40E+01 8.64E+OO pCi/kg Page 50 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine - Rockfish Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Cesium-134
-1.78E-01 4.86E+OO 2.90E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Cesium-134 1.67E+OO 4.81E+OO 3.24E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Cesium-134 2.82E-01 6.82E+OO 3.97E+OO pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Cesium-134
-1.22E+OO 4.03E+OO 2.99E+OO pCi/kg DCM Diablo Cove Marine(343132002) - FH Rockfsh 17-Jan-14 Cesium-137
-4.77E+OO 5.26E+OO 4.46E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Cesium-137 3.07E+OO 4.49E+OO 4.81 E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Cesium-137 9.65E-01 6.21 E+OO 3.71E+OO pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Cesium-137 1.31 E+OO 3.57E+OO 4.52E+OO pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Cobalt-58 2.79E+OO 5.61 E+OO 3.50E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Cobalt-58
-1.40E+OO 4.73E+OO 2.99E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Cobalt-58 1.54E+OO 7.19E+OO 4.18E+OO pCi/kg DCM Diablo Cove Marine(361289002) - FH Rockfsh 11-Nov-14 Cobalt-58 1.77E+OO 4.19E+OO 2.55E+OO pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Cobalt-60 1.50E-01 5.03E+OO 2.96E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Cobalt-60
-8.76E-01 5.47E+OO 3.31 E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Cobalt-60
-2.01E+OO 6.33E+OO 4.08E+OO pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Cobalt-60
-2.27E+OO 4.02E+OO 2.80E+OO pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Iron-59
-6.24E+OO 1.52E+01 1.01 E+01 pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Iron-59 5.51 E+OO 1.28E+01 7.86E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Iron-59
-2.90E+OO 1.69E+01 1.03E+01 pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Iron-59
-1.70E+OO 9.88E+OO 5.99E+OO pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Manganese-54
-6.47E-01 4.68E+OO 2.84E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Manganese-54
-3.99E+OO 4.32E+OO 3.39E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Manganese-54 2.85E+OO 6.20E+OO 3.71E+OO pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Manganese-54
-6.53E-01 3.59E+OO 2.23E+OO pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Potassium-40 3.59E+03 3.98E+01 3.50E+02 pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Potassium-40 3.45E+03 4.14E+01 3.42E+02 pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Potassium-40 3.53E+03 5.21 E+01 3.53E+02 pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Potassium-40 3.33E+03 3.86E+01 3.09E+02 pCi/kg DCM Diablo Cove Marine(343132002)- FH Rockfsh 17-Jan-14 Zinc-65 4.33E+OO 1.19E+01 6.96E+OO pCi/kg DCM Diablo Cove Marine(349673002) - FH Rockfsh 23-May-14 Zinc-65
-1.04E-01 1.23E+01 7.47E+OO pCi/kg DCM Diablo Cove Marine(355525007) - FH Rockfsh 21-Aug-14 Zinc-65 9.55E+OO 1.61 E+01 8.44E+OO pCi/kg DCM Diablo Cove Marine(361289002)- FH Rockfsh 11-Nov-14 Zinc-65
-5.37E+OO 9.72E+OO 6.58E+OO pCi/kg DCM Diablo Cove Marine-Intertidal Mussel Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(342255001)- IM 28-Jan-14 Cesium-134
-5.98E-01 4.78E+OO 2.85E+OO pCi/kg DCM Diablo Cove Marine(349258002)- IM 19-May-14 Cesium-134
-9.05E-03 3.48E+OO 2.08E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Cesium-134 1.12E+OO 3.75E+OO 2.17E+OO pCi/kg DCM Diablo Cove Marine(360799003) - IM 4-Nov-14 Cesium-134 3.31 E-01 4.03E+OO 2.35E+OO pCi/kg DCM Diablo Cove Marine(342255001) - IM 28-Jan-14 Cesium-137 2.21E+OO 4.85E+OO 2.97E+OO pCi/kg DCM Diablo Cove Marine(349258002) - IM 19-May-14 Cesium-137 2.39E+OO 3.53E+OO 2.23E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Cesium-137 2.15E+OO 3.63E+OO 2.29E+OO pCi/kg Page 51 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(360799003) - IM 4-Nov-14 Cesium-137 1.17E+OO 3.67E+OO 3.68E+OO pCi/kg DCM Diablo Cove Marine(342255001) - IM 28-Jan-14 Cobalt-58 9.41 E-03 4.31 E+OO 2.52E+OO pCi/kg DCM Diablo Cove Marine(349258002) - IM 19-May-14 Cobalt-58 1.29E+OO 3.44E+OO 2.05E+OO pCi/kg DCM Diablo Cove Marine(353262001) - IM 17-Jul-14 Cobalt-58 1.23E-01 3.33E+OO 2.22E+OO pCi/kg DCM Diablo Cove Marine(360799003)- IM 4-Nov-14 Cobalt-58 1.19E+OO 4.22E+OO 2.46E+OO pCi/kg DCM Diablo Cove Marine(342255001)- IM 28-Jan-14 Cobalt-60 8.44E-01 5.02E+OO 2.90E+OO pCi/kg DCM Diablo Cove Marine(349258002)- IM 19-May-14 Cobalt-60 8.07E-01 3.93E+OO 3.30E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Cobalt-60 1.78E+OO 4.11E+OO 2.46E+OO pCi/kg DCM Diablo Cove Marine(360799003) -1M 4-Nov-14 Cobalt-60 3.61 E+OO 4.52E+OO 3.45E+OO pCi/kg DCM Diablo Cove Marine(342255001)- IM 28-Jan-14 Iron-59 6.68E-01 9.77E+OO 5.82E+OO pCi/kg DCM Diablo Cove Marine(349258002)- IM 19-May-14 Iron-59 1.21 E+OO 7.85E+OO 4.73E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Iron-59
-4.89E+OO 6.82E+OO 5.06E+OO pCi/kg DCM Diablo Cove Marine(360799003) - IM 4-Nov-14 Iron-59
-3.14E+OO 8.80E+OO 5.90E+OO pCi/kg DCM Diablo Cove Marine(342255001) - IM 28-Jan-14 Manganese-54
-6.80E-01 4.36E+OO 2.62E+OO pCi/kg DCM Diablo Cove Marine(349258002) - IM 19-May-14 Manganese-54
-1.89E-02 3.18E+OO 1.91 E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Manganese-54 1.10E+OO 3.50E+OO 2.04E+OO pCilkg DCM Diablo Cove Marine(360799003)- IM 4-Nov-14 Manganese-54 6.09E-01 3.70E+OO 2.20E+OO pCi/kg DCM Diablo Cove Marine(342255001)- IM 28-Jan-14 Potassium-40 2.06E+03 4.07E+01 2.22E+02 pCi/kg DCM Diablo Cove Marine(349258002)- IM 19-May-14 Potassium-40 1.73E+03 2.83E+01 1.77E+02 pCi/kg DCM Diablo Cove Marine(353262001)- IM 17 -Jul-14 Potassium-40 1.27E+03 2.62E+01 1.34E+02 pCi!kg DCM Diablo Cove Marine(360799003)- IM 4-Nov-14 Potassium-40 1.47E+03 3.44E+01 1.62E+02 pCi/kg DCM Diablo Cove Marine(342255001)- IM 28-Jan-14 Zinc-65
-1.41 E+OO 1.05E+01 6.46E+OO pCi/kg DCM Diablo Cove Marine(349258002)- IM 19-May-14 Zinc-65
-8.79E-02 8.25E+OO 5.36E+OO pCi/kg DCM Diablo Cove Marine(353262001)- IM 17-Jul-14 Zinc-65 3.97E-01 8.24E+OO 5.61 E+OO pCi/kg DCM Diablo Cove Marine(360799003)- IM 4-Nov-14 Zinc-65
-1.68E+OO 9.33E+OO 5.78E+OO pCi/kg DCM Diablo Cove Marine - Ocean Sediment Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Barium-140
-1.59E+01 1.29E+02 8.42E+01 pCi!kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Bismuth-214 6.44E+02 1.08E+02 1.58E+02 pCi/kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Cesium-134 4.13E+01 8.98E+01 5.00E+01 pCi/kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Cesium-137 2.39E+01 6.84E+01 3.72E+01 pCi!kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Cobalt-58 2.14E+01 8.12E+01 4.50E+01 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Cobalt-60
-1.24E+01 5.56E+01 3.63E+01 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Iron-55
-5.22E+03 1.46E+04 1.00E+04 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Iron-59
-5.82E+01 1.23E+02 9.36E+01 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Lanthanum-140
-1.59E+01 1.29E+02 8.42E+01 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Lead-214 8.31 E+02 3.07E+02 1.89E+02 pCi/kg DCM Diablo Cove Marine(343203001) - SO 5-Feb-14 Manganese-54
-7.06E+OO 5.77E+01 3.53E+01 pCi!kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Nickel-63 1.57E+02 2.24E+03 1.34E+03 pCilkg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Niobium-95
-1.31 E+01 8.32E+01 5.01 E+01 pCilkg DCM Diablo Cove Marine(343203001) - SO 5-Feb-14 Potassium-40 9.65E+03 6.36E+02 1.67E+03 pCi/kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Total Strontium
-4.99E+02 7.46E+02 3.59E+02 pCi/kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Zinc-65 1.07E+OO 1.54E+02 1.07E+02 pCi/kg DCM Diablo Cove Marine(343203001)- SO 5-Feb-14 Zirconium-95
-3.20E+01 9.53E+01 6.41E+01 pCi/kg Page 52 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine - Seawater Sample Name Date Collected Nuclide Result MDC 2 Sigma TPU Units DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 BETA 1.72E+02 9.92E+01 7.33E+01 pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 BETA 1.64E+02 8.28E+01 6.45E+01 pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 BETA 2.22E+02 2.13E+02 1.37E+02 pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 BETA 2.70E+02 1.66E+02 1.16E+02 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 BETA 1.67E+02 9.46E+01 6.87E+01 pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 BETA 4.09E+02 1.30E+02 1.14E+02 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 BETA 1.95E+02 8.58E+01 7.00E+01 pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 BETA 4.00E+02 1.30E+02 1.13E+02 pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 BETA 3.22E+02 1.70E+02 1.22E+02 pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 BETA 1.24E+02 1.09E+02 7.39E+01 pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 BETA 3.29E+02 1.09E+02 9.70E+01 pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 BETA 3.30E+02 1.27E+02 1.03E+02 pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Barium-140 5.88E-01 4.01 E+OO 2.33E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Barium-140 6.52E-01 3.85E+OO 2.24E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Barium-140 1.39E+OO 4.31 E+OO 2.49E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Barium-140 1.07E+OO 3.07E+OO 1.81 E+OO pCi/L DCM Diablo Cove Marine(348878003)- SW 12-May-14 Barium-140 2.72E-01 3.62E+OO 2.45E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Barium-140 5.83E-01 2.90E+OO 1.96E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Barium-140
-8.93E-01 2.86E+OO 2.12E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Barium-140
-7.77E-02 3.60E+OO 2.16E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Barium-140
-4.36E-01 3.43E+OO 2.29E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Barium-140
-9.50E-01 3.05E+OO 2.28E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Barium-140
-9.09E-01 3.34E+OO 2.47E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Barium-140 4.17E-03 3.14E+OO 1.87E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Cesium-134
-5.16E-01 2.43E+OO 1.48E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Cesium-134
-5.87E-01 2.22E+OO 1.36E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Cesium-134
-6.11 E-01 2.83E+OO 1.71E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Cesium-134 6.50E-03 1.93E+OO 1.14E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Cesium-134 7.80E-01 2.28E+OO 1.50E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Cesium-134
-2.69E-01 1.73E+OO 1.16E+OO pCi/L DCM Diablo Cove Marine(3531 00002) - SW 15-Jul-14 Cesium-134
-1.34E-01 1.71E+OO 1.01 E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Cesium-134 1.33E+OO 2.21 E+OO 1.57E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Cesium-134 3.08E-01 2.02E+OO 1.18E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Cesium-134 1.18E+OO 2.26E+OO 1.62E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Cesium-134 6.05E-01 2.26E+OO 1.45E+OO pCi/L DCM Diablo Cove Marine(363121 003)- SW 8-Dec-14 Cesium-134
-1.82E-01 1.89E+OO 1.16E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Cesium-137 1.04E+OO 2.52E+OO 1.54E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Cesium-137
-9.82E-03 2.19E+OO 1.52E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Cesium-137
-1.05E+OO 2.64E+OO 3.04E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Cesium-137 9.54E-01 1.82E+OO 2.27E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Cesium-137 1.84E+OO 2.30E+OO 1.33E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Cesium-137
-6.82E-01 2.29E+OO 1.90E+OO pCi/L Page 53 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Cesium-137
-1.55E+OO 1.98E+OO 1.76E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Cesium-137 2.88E-01 2.12E+OO 1.27E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Cesium-137
-6.81 E-01 1.91 E+OO 1.20E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Cesium-137 8.86E-01 2.30E+OO 1.38E+OO pCi/L DCM Diablo Cove Marine(360977002)- SW 5-Nov-14 Cesium-137 1.78E+OO 2.00E+OO 2.09E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Cesium-137 5.85E-01 1.92E+OO 1.11E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Cobalt-58
-5.11 E-01 2.25E+OO 1.59E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Cobalt-58 8.58E-01 2.19E+OO 1.29E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Cobalt-58
-9.01 E-01 2.44E+OO 1.80E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Cobalt-58
-2.43E-01 1.72E+OO 1.04E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Cobalt-58
-7.06E-01 2.06E+OO 1.54E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Cobalt-58
-3.14E-01 1.65E+OO 1.12E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Cobalt-58 4.50E-01 1.58E+OO 1.05E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Cobalt-58
-8.90E-01 1.92E+OO 1.44E+OO pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Cobalt-58 9.42E-01 2.02E+OO 1.21 E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Cobalt-58
-1.23E+OO 1.91 E+OO 1.37E+OO pCi/L DCM Diablo Cove Marine(360977002)- SW 5-Nov-14 Cobalt-58
-4.55E-01 2.09E+OO 1.32E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Cobalt-58 1.22E+OO 1.96E+OO 1.22E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Cobalt-60 1.23E+OO 2.71 E+OO 1.65E+OO pCi/L DCM Diablo Cove Marine(343846002)- SW 24-Feb-14 Cobalt-60 4.12E-02 2.34E+OO 1.41 E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Cobalt-60
-1.76E+OO 2.42E+OO 1.80E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Cobalt-60
-4.40E-01 1.85E+OO 1.14E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Cobalt-60
-3.56E-01 2.08E+OO 1.52E+OO pCi/L DCM Diablo Cove Marine(351324003) - SW 19-Jun-14 Cobalt-60 4.60E-01 1.87E+OO 1.09E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Cobalt-60
-1.14E-01 1.67E+OO 1.03E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Cobalt-60
-1.13E+OO 2.05E+OO 1.39E+OO pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Cobalt-60
-1.20E+OO 1.77E+OO 1.28E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Cobalt-60 7.77E-01 2.46E+OO 1.46E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Cobalt-60
-5.04E-01 2.11 E+OO 1.31 E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Cobalt-60 1.22E-01 1.99E+OO 1.16E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 lodine-131 1.10E+OO 4.10E+OO 2.40E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 lodine-131 1.04E+OO 4.24E+OO 2.59E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 lodine-131
-9.31 E-01 4.84E+OO 2.90E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 lodine-131 9.77E-01 3.21 E+OO 1.91 E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 lodine-131 1.53E-01 4.10E+OO 2.47E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 lodine-131 1.39E+OO 3.28E+OO 1.99E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 lodine-131 1.08E+OO 3.59E+OO 2.14E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 lodine-131 7.09E-01 3.58E+OO 2.18E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 lodine-131
-6.41 E-01 4.25E+OO 2.58E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 lodine-131
-1.93E+OO 3.88E+OO 2.59E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 lodine-131 1.02E+OO 4.00E+OO 2.74E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 lodine-131 1.07E+OO 3.40E+OO 2.25E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Iron-55 4.79E+OO 1.04E+02 7.13E+01 pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Iron-55
-5.80E+01 9.33E+01 6.55E+01 pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-11__ ---
Iron-55
-2.29E+01 8.40E+01 6.13E+01 pCi/L Page 54 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Iron-55 1.68E+01 9.60E+01 6.79E+01 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Iron-55
-1.29E+01 7.49E+01 5.28E+01 pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Iron-55 1.44E+01 6.51 E+01 4.52E+01 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Iron-55
-9.03E+01 1.14E+02 7.87E+01 pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Iron-55
-1.37E+01 9.25E+01 6.73E+01 pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Iron-55 4.00E+01 7.93E+01 5.58E+01 pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Iron-55 1.96E+01 7.92E+01 5.80E+01 pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Iron-55
-1.14E+01 7.53E+01 5.17E+01 pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Iron-55 1.63E+01 4.33E+01 3.06E+01 pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Iron-59
-2.27E-01 5.31E+OO 3.21 E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Iron-59 2.31 E+OO 4.76E+OO 2.89E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Iron-59
-1.96E+OO 5.73E+OO 4.28E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Iron-59
-3.66E-01 3.72E+OO 2.29E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Iron-59
-5.94E-02 4.27E+OO 2.95E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Iron-59 9.23E-01 3.68E+OO 2.21 E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Iron-59
-9.20E-01 3.66E+OO 2.67E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Iron-59
-4.27E-01 4.29E+OO 2.62E+OO pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Iron-59
-2.05E-01 4.21 E+OO 2.56E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Iron-59 1.28E+OO 5.02E+OO 3.37E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Iron-59
-9.04E-01 4.36E+OO 2.66E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Iron-59
-3.33E-01 3.87E+OO 2.36E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Lanthanum-140 5.88E-01 4.01E+OO 2.33E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Lanthanum-140 6.52E-01 3.85E+OO 2.24E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Lanthanum-140 1.39E+OO 4.31 E+OO 2.49E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Lanthanum-140 1.07E+OO 3.07E+OO 1.81 E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Lanthanum-140 2.72E-01 3.62E+OO 2.45E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Lanthanum-140 5.83E-01 2.90E+OO 1.96E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Lanthanum-140
-8.93E-01 2.86E+OO 2.12E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Lanthanum-140
-7.77E-02 3.60E+OO 2.16E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Lanthanum-140
-4.36E-01 3.43E+OO 2.29E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 La nth an um-140
-9.50E-01 3.05E+OO 2.28E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Lanthanum-140
-9.09E-01 3.34E+OO 2.47E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Lanthanum-140 4.17E-03 3.14E+OO 1.87E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Manganese-54 1.16E+OO 2.25E+OO 1.35E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Manganese-54
-1.16E+OO 1.82E+OO 1.26E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Manganese-54
-4.23E-01 2.68E+OO 1.61 E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Manganese-54 7.47E-02 1.69E+OO 9.99E-01 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Manganese-54
-4.73E-01 2.09E+OO 1.32E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Manganese-54
-3.32E-01 1.59E+OO 9.80E-01 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Manganese-54 7.17E-02 1.61 E+OO 1.09E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Manganese-54 1.51 E-01 1.97E+OO 1.15E+OO pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Manganese-54 3.01 E-03 1.72E+OO 1.02E+OO pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Manganese-54 5.93E-02 2.24E+OO 1.35E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Manganese-54
-7.01 E-01 2.13E+OO 1.32E+OO pCi/L DCM Diablo Cove Marir1e(363121003)- SW 8-Dec-14 Manganese-54 2.35E-01 1.73E+OO 1.01 E+OO pCi/L Page 55 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Nickel-63
-1.33E+01 3.86E+01 2.24E+01 pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Nickel-63 6.56E+OO 3.04E+01 1.84E+01 pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Nickel-63 3.45E+OO 3.44E+01 2.07E+01 pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Nickel-63 2.51E+OO 3.38E+01 2.03E+01 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Nickel-63
-1.08E+OO 2.96E+01 1.76E+01 pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Nickel-63 2.32E+01 3.26E+01 2.07E+01 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Nickel-63 2.63E+01 3.53E+01 2.27E+01 pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Nickel-63
-1.93E+01 3.67E+01 2.11E+01 pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Nickel-63
-2.02E+01 3.88E+01 2.23E+01 pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Nickel-63
-9.58E+OO 3.05E+01 1.79E+01 pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Nickel-63
-1.28E+01 3.58E+01 2.09E+01 pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Nickel-63 7.76E+OO 2.88E+01 1.75E+01 pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Niobium-95 1.08E+OO 2.53E+OO 1.50E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Niobium-95 3.44E-01 2.18E+OO 1.52E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Niobium-95 3.84E-01 2.79E+OO 1.68E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Niobium-95
-3.58E-01 1.87E+OO 1.14E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Niobium-95 7.90E-01 2.23E+OO 1.34E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Niobium-95 1.16E-01 1.76E+OO 1.03E+OO pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Niobium-95
-3.98E-01 1.65E+OO 1.01 E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Niobium-95 1.88E+OO 1.88E+OO 1.34E+OO' pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Niobium-95 6.43E-01 2.11 E+OO 1.24E+OO pCi/L DCM Diablo Cove Marine(359457003)- SW 15-0ct-14 Niobium-95
-6.38E-01 2.11 E+OO 1.34E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Niobium-95 1.62E+OO 2.32E+OO 1.67E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Niobium-95 2.88E-01 1.71 E+OO 1.94E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Potassium-40 3.47E+02 2.46E+01 5.26E+01 pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Potassium-40 3.59E+02 1.86E+01 5.05E+01 pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Potassium-40 3.62E+02 2.33E+01 5.29E+01 pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Potassium-40 3.42E+02 1.79E+01 4.67E+01 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Potassium-40 3.65E+02 1.96E+01 5.18E+01 pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Potassium-40 3.45E+02 1.61 E+01 4.55E+01 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Potassium-40 3.33E+02 1.44E+01 4.28E+01 pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Pbtassium-40 3.12E+02 1.74E+01 5.17E+01 pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Potassium-40 3.46E+02 1.88E+01 4.98E+01.
- pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Potassium-40 3.23E+02 2.04E+01 5.13E+01 pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Potassium-40 3.19E+02 1.97E+01 4.48E+01 pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Potassium-40 3.43E+02 1.63E+01 4.68E+01 pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Total Strontium 1.65E+OO 2.00E+OO 1.30E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Total Strontium
-1.66E+OO 2.98E+OO 1.70E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Total Strontium 3.11 E+OO 3.91 E+OO 2.53E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Total Strontium
-3.17E+OO 3.49E+OO 1.95E+OO pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Total Strontium 5.63E-01 3.86E+OO 2.32E+OO pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Total Strontium
-4.41 E-02 1.67E+OO 9.91 E-01 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Total Strontium
-4.55E-01 3.57E+OO 2.11E+OO pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Total Strontium 2.02E+OO 2.62E+OO 1.71 E+OO pCi/L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Total Strontium
-2.22E-01 2.80E+OO 1.66E+OO pCi/L Page 56 of 92
2014 DCPP REMP Analysis Results Appendix C DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Total Strontium 2.99E+OO 3.65E+OO 2.36E+OO pCi/L I
DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Total Strontium
-3.1 OE-01 2.50E+OO 1.47E+OO pCi/L DCM Diablo Cove Marine(363121 003)- SW 8-Dec-14 Total Strontium 4.79E-02 3.66E+OO 2.18E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Tritium 1.21 E+02 2.47E+02 1.55E+02 pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Tritium 1.15E+01 2.65E+02 1.59E+02 pCi!L i
DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Tritium 5.79E+01 2.45E+02 1.49E+02 pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Tritium
-2.21 E+OO 2.59E+02 1.54E+02 pCi/L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Tritium
-8.73E+01 2.29E+02 1.31 E+02 pCi/L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Tritium
-1.83E+01 2.56E+02 1.51 E+02 pCi/L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Tritium 8.44E+01 2.53E+02 1.56E+02 pCi/L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Tritium 5.64E+01 2.23E+02 1.37E+02 pCi/L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Tritium
-1.71 E+02 2.75E+02 1.56E+02 pCi/L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Tritium 1.40E+02 2.48E+02 1.58E+02 pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Tritium
-1.83E+01 2.59E+02 1.53E+02 pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Tritium 1.45E+01 2.69E+02 1.61 E+02 pCi!L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Zinc-65
-2.15E+OO 4.98E+OO 3.32E+OO pCi/L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Zinc-65
-4.69E+OO 3.95E+OO 3.49E+OO pCi!L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Zinc-65
-2.53E+OO 5.33E+OO 4.15E+OO pCi!L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Zinc-65 8.53E-02 3.89E+OO 2.36E+OO pCi!L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Zinc-65
-2.57E+OO 4.28E+OO 2.98E+OO pCi!L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Zinc-65 1.21 E+OO 3.72E+OO 2.56E+OO pCi!L DCM Diablo Cove Marine(353100002)- SW 15-Jul-14 Zinc-65 1.22E+OO 3.61E+OO 2.45E+OO pCi!L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Zinc-65
-2.48E+OO 4.04E+OO 3.31 E+OO pCi!L DCM Diablo Cove Marine(356752003) - SW 8-Sep-14 Zinc-65
-4.54E-01 4.10E+OO 2.53E+OO pCi!L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Zinc-65 1.01 E+OO 4.63E+OO 3.12E+OO pCi!L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Zinc-65 1.61 E+OO 4.35E+OO 2.91 E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Zinc-65 7.01 E-02 3.80E+OO 2.65E+OO pCi/L DCM Diablo Cove Marine(342317002)- SW 27-Jan-14 Zirconium-95
-6.40E-01 4.13E+OO 2.46E+OO pCi!L DCM Diablo Cove Marine(343846002) - SW 24-Feb-14 Zirconium-95 1.04E+OO 3.82E+OO 2.30E+OO pCi/L DCM Diablo Cove Marine(345420002) - SW 24-Mar-14 Zirconium-95
-1.79E-01 4.78E+OO 2.91 E+OO pCi/L DCM Diablo Cove Marine(346578002) - SW 7-Apr-14 Zirconium-95 1.01 E-01 3.18E+OO 1.87E+OO pCi!L DCM Diablo Cove Marine(348878003) - SW 12-May-14 Zirconium-95 4.35E-01 3.58E+OO 2.13E+OO pCi!L DCM Diablo Cove Marine(351324003)- SW 19-Jun-14 Zirconium-95 9.77E-01 3.14E+OO 1.85E+OO pCi!L DCM Diablo Cove Marine(3531 00002)- SW 15-Jul-14 Zirconium-95 8.49E-01 2.96E+OO 1.72E+OO pCi!L DCM Diablo Cove Marine(354812003)- SW 11-Aug-14 Zirconium-95
-6.87E-01 3.54E+OO 2.13E+OO pCi!L DCM Diablo Cove Marine(356752003)- SW 8-Sep-14 Zirconium-95 8.62E-01 3.59E+OO 2.10E+OO pCi!L DCM Diablo Cove Marine(359457003) - SW 15-0ct-14 Zirconium-95
-7.32E-01 3.75E+OO 2.33E+OO pCi/L DCM Diablo Cove Marine(360977002) - SW 5-Nov-14 Zirconium-95 2.05E+OO 4.00E+OO 2.81 E+OO pCi/L DCM Diablo Cove Marine(363121003)- SW 8-Dec-14 Zirconium-95 9.15E-01 3.58E+OO 2.14E+OO pCi!L Page 57 of 92