Amends 113,113 & 110 to Licenses DPR-38,DPR-47 & DPR-55, Respectively,Revising Tech Specs to Allow Full Power Operation of Unit 3 During Fuel Cycle 7
ML15112B063
Person / Time
Site: Oconee  
(DPR-038, DPR-047, DPR-055)
Issue date: 09/29/1982
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Duke Power Co
Shared Package
ML15112B064 List:
References
DPR-38-A-113, DPR-47-A-113, DPR-55-A-110 NUDOCS 8210190154
Download: ML15112B063 (31)


Text

.

oq, UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 DUKE POWER COMPANY DOCKET 110.

50-269 OCONEE NUCLEAR STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.113 License No. DPR-38

1. The Nuclear Regulatory Commission (the Commission) has found that:

A The application for amendment by Duke Power Company (the licensee) dated flay 3, 1982, as revised August 11, 1922, and supplemented August 16, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as ame nded (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the pro visions of the Act, and the rules and regulations of the -Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satis fied.

2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph3.B of Facility Operating License No. DPR-38 is hereby amended to read as follows:

3.B Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 1i3are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

F 210190154 820929 PDR ADOCK 05000269 P

PDR

-2

3. This license amendment is effective as of the date of its.issuance.

FOR THE NUCLEAR REGULATORY COMMISSION hn' F. Stolz, Chief per ting Reactors Branch #4 i sion of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: September 29, 1982

01 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON. D. C. 20555 DUKE POWER COMPANY DOCKET NO.

50-270 OCONEE NUCLEAR STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 113 License No.

DPR-47

1. The Nuclear Regulatory Commission (the Commission) has found that:

A. The application for amendment by Duke Power Company (the licensee) dated flay 3, 1982, as revised August 11, 1982, and supplemented August 16, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the pro visions of the Act, and the rules and regulations of the-Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satis fied.

2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 3.B of Facility Operating License No. DPR-47 is hereby amended to read as follows:

3.B Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 113are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

-2

3. This license amendment is effective as of the date of its.issuance.

FOR THE NUCLEAR REGULATORY COMMISSION hn F. Stolz, Chief per ting Reactors Branch 4 i sion of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: September 29, 1982

UNITED STATES NUCOAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 DUKE POWER COMPANY DOCKET NO. 50- 287 OCONEE NUCLEAR STATION, UNIT NO. 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 110 License No.

DPR-55

1. The Nuclear Regulatory Commission (the Commission) has found that:

A. The application for amendment by Duke Power Company (the licensee) dated fay 3, 1982, as revised August 11, 1932, and supplemented August 16, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act)., and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the pro visions of the Act, and the rules and regulations of the -Commission; C. There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satis fied.

2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 3.B of Facility Operating License No. DPR-55 is hereby amended to read as follows:

3.B Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 110are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

  • g.

gS

-2

3. This license amendment is effective as of the date of its.issuance.

FOR THE NUCLEAR REGULATORY COMMISSION hin F. Stolz, Chief per ting Reactors Branch #4 i sion of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: September 29, 1982

ATTACHMENTS TO LICENSE AMENDMENTS AMENDMENT NO.113 TO DPR-38 AMENDMENT NO.113 TO DPR-47 AMENDMENT NO.110 TO DPR-55 DOCKETS NOS.

50-269, 50-270 AND 50-287 Replace the following pages of the Appendix "A Technical Specifications wit th atachd pges The revised pages are identified by aendmient numbers and contain vertical lines indicating the area of change.

Remove Payes insert Pages 2.1-2 2.1-2 2.1-3b 2.1-3b 2.1-3b 2.1-3d 2.1-6 2.1-6 2.1-9 2.1-9 2.1-12 2.1-12 2.3-10 2.3-10 3.2-2 3.2-2 3.5-9 3.5-9 3.5-17 3.5-17 3.5-17 3.5-17a 3.5-17a 3.5-17b 3.5-17b 3.5-20 3.5-20 3.5-20a 3.5-20a 3.5-20b 3.5-20b 3.5-20c 3.5-20d 3.5-20e 3.5-23e 3.5-23 3.5-23 3.5-?3a 3.5-23a 3.5-23b 3.5-23b 3.5-26 3.5-26 3.5-26a 3.5-26a 3.5-26b 3.5-26b

a can be related to DNB through the use of the BAW-2 correlation (1).

The BAW-2 correlation has been developed to predict DNB and the location of DNB for axially uniform and non-uniform heat flux distributions. The local DNB ratio (DNBR), defined as the ratio of the heat flux that would cause DNB at a particular core location to the actual heat flux, is indicative of the margin to DNB. The minimum value of the DNBR, during steady-state operation, normal operational transients, and anticipated transients is limited to 1.30. A DNBR of 1.30 corresponds to a 95 percent probability at a 95 percent confidence level that DNB will not occur; this is considered a conservative margin to DNB for all operating conditions. The difference between the actual core outlet pressure and the indicated reactor coolant system pressure has been considered in determining the core protection safety limits.

The difference in these two pressures is nominally 45 psi; however, only a 30 psi drop was assumed in reducing the pressure trip setpoints to correspond to the elevated location where the pressure is actually measured.

The curve presented in Figure 2.1-1A represents the conditions at which a minimum DNBR of 1.30 is predicted for the maximum possible thermal power (112 percent) when four reactor coolant pumps are operating (minimum reactor coolant flow is 106.5 percent of 131.3 x 106 lbs/hr).

This curve is based on the combination of nuclear power peaking factors, with potential effects of fuel densification and rod bowing, which result in a more conservative DNBR than any other shape that exists during normal operation.

The curves of Figure 2.1-2A are based on the more restrictive of two thermal limits and include the effects of potential fuel densification and rod bowing:

1.

The 1.30 DNBR limit produced by the combination of the radial peak, axial peak and position of the axial peak that yields no less than a 1.30 DNBR.

2.

The combination of radial and axial peak that causes central fuel melting at the hot spot. The limit is 20.05 kw/ft for Unit 1.

Power peaking is not a directly observable quantity and therefore limits have been established on the bases of the reactor power imbalance produced by the power peaking.

The specified flow rates of Figure 2.1-3A correspond to the expected minimum flow rates with four pumps, three pumps, and one pump in each loop, respectively.

The curve of Figure 2.1-lA is the most restrictive of all possible reactor coolant pump-maximum thermal power combinations shown in Figure 2.1-3A.

The magnitude of the rod bow penalty applied to each fuel cycle is equal to or greater than the necessary burnup dependent DNBR rod bow penalty for the ap plicable cycle minus a credit of 1% for the flow area reduction factor used in the hot channel analysis. All plant operating limits are based on a minimum DNBR criteria of 1.30 plus the amount necessary to offset the reduction in DNBR due to fuel rod bow.

Amendments Nos.

113, 113, & 110 2.1-2

1.

The 1.30 DNBR limit produced by the combination of the radial peak, axial peak and position of the axial peak that yields no less than a 1.30 DNBR.

2.

The combination of radial and axial peak that causes central fuel melting at the hot spot. The limit is 20.15 kw/ft for Unit 2.

Power peaking is not a directly observable quantity, and, therefore, limits have been established on the bases of the reactor power imbalance produced by the power peaking.

The specified flow rates of Figure 2.1-3B correspond to the expected minimum flow rates with four pumps, three pumps, and one pump in each loop, respectively.

The curve of Figure 2.1-1B is the most restrictive of all possible reactor coolant pump-maximum thermal power combinations shown in Figure 2.1-3B.

The magnitude of the rod bow penalty applied to each fuel cycle is equal to or greater than the necessary burnup dependent DNBR rod bow penalty for the ap plicable cycle minus a credit of 1% for the flow area reduction factor used in the hot channel analysis. All plant operating limits are based on a minimum DNBR criteria of 1.30 plus the amount necessary to offset the reduction in DNBR due to fuel rod bow.

(3)

The maximum thermal power for three-pump operation is 90.606 percent due to a power level trip produced by the flux-flow ratio 74.7 percent flow x 1.08 =

80.68 percent power plus the maximum calibration and instrument error. The maximum thermal power for other coolant pump conditions is produced in a

similar manner.

For each curve of Figure 2.1-3B, a pressure-temperature point above and to the left of the curve would result in a DNBR greater than 1.30 or a local quality at the point of minimum DNBR less than 22 percent for that particular reactor coolant pump situation. The curve of Figure 2.1-lB is the most restrictive of all possible reactor coolant pump-maximum thermal power combinations shown in Figure 2.1-3B.

References (1) Correlation of Critical Heat Flux in a Bundle Cooled by Pressurizer Water, BAW-10000, March 1970.

(2) Oconee 2, Cycle 4 - Reload Report, BAW-1491, August 1978.

(3) Oconee 2, Cycle 6 -

Reload Report, BAW-1691, August 1981.

Amendments ilos.. 113 113

& 110 2.1-3b

2.

The combination of radial and axial peak that causes central fuel melting at the hot spot. The limits for Unit 3 are 20.5 kw/ft for fuel rod burn up less than or equal to 10,000 MWD/MTU and 21.5 kw/ft - after 10,000 MWD/TU.

Power peaking is not a directly observable quantity, and, therefore, limits have been established on the bases of the reactor power imbalance produced by the power peaking.

The specified flow rates of Figure 2.1-3C correspond to the expected minimum flow rates witb four pumps, three pumps, and one pump in each loop, respectively.

The magnitude of the rod bow penalty applied to each fuel cycle is equal to or greater than the necessary burnup dependent DNBR rod bow penalty for the ap plicable cycle minus a credit of 1% for the flow area reduction factor used in the hot channel analysis. All plant operating limits are based on a minimum DNBR criteria of 1.30 plus the amount necessary to offset the reduction in DNBR due.to fuel rod bow. (4)

The maximum thermal power for three-pump operation is 90.65 percent due to a power level trip produced by the flux-flow ration 74.7 percent flow x 1.08 =

80.7 percent power plus the maximum calibration and instrument error (Reference 4).

The maximum thermal power for other coolant pump conditions are produced in a similar manner.

For each curve of Figure 2.1-3C a pressure-temperature point above and to the left of the curve would result in a DNBR greater than 1.30 or a local quality at the point of minimum DNBR less than 22 percent for that particular reactor coolant pump situation. The curve of Figure 2.1-1C is the most restrictive of all possible reactor coolant pump-maximum thermal power combinations shown in Figure 2.1-3C.

References (1) Correlation of Critical Heat Flux in a Bundle Cooled by Pressurized Water, BAW-10000, March 1970.

(2) Oconee 3, Cycle 3 -

Reload Report -

BAW-1453, August 1977.

(3). Amendment 1 - Oconee 3, Cycle 4 -

Reload Report -.BAW-1486, June 12, 1978.

(4) Oconee 3, Cycle 7 -

Reload Report -

DPC-RD-2001, Revision 1, July 1982.

kiendments Nos.

113,113

, &110 2.1-3d

2400 ACCEPT4BLE OPERATION 2200

-2000 6

10000 UNACCEPTABLE OPERATION 1600 580 600 620 640 660 Reactor Coolant Core Outlet Temperature,oF CORE PROTECTION SAFETY LIMITS UNIT 3 ounPowE, OCONEE NUCLEAR STATION Figure 2.1-1C Amendments lOs. 113, 113.

&110 2.1-6

THERMAL POWER LEVEL,%

Ml =0.529

-120

(-32.5,1.12.0)

(33.0,112.0)

M2= -1.864 I ACCEPTABLE

(-49.5,103.0) 4 PUMP OPERATION (3., 0.64)

(-32.5t90.64)

(3 3.0, 0.64 ACCEPTAB LEI

(-49.5,81.64) 3 & 4 PUMP

-80 (49.5,81.25)

OPE RATION

(-32. 163.26)

(33.0163.26) 1

-60 (49.5,59.89)

I ACCEPTABLE

(-49.5,54.76)

(-4.554.6)1 2,3, & 4 PUMP I

OPERATION

- 40 (49.5,32.51)

-20 1III II

-60

-40

-20 20 40 60 REACTOR POWER IMBALANCE;%

IMT CORE PROTECTION SAFETY LIM7' UNIT 3 KEPOWER OCONEE NUCLEAR STATION Figure 2.1-2C Amendments Nos.

113,

113, &110 2.1-9

g g

2400 ACCEPT BLE

/

2200 OPERATION

/

  • 4 PUMPIN 2000' 0

/22PUMP 3 3PUMP UNACCEPTABLE OPERATFION 1600 580 600 620 640 660 Reactor Coolant Core Outlet Temperature, OF PUMPS COOLANT POWER TYPE OF LIMIT OPERATING FLOW (GPM)

(% FP) 4 374,880(100%)

112.0 DNBR

.3 280,035(74.7%)

90.7 DNBR 2

183,690(49.0%)

63.63 DNBR/QUALITY CORE PROTECTION SAFETY LIMITS UNIT 3 o

OCONEE NUCLEAR STATION Figure 2.1-3C Amendments NOS.

1136 113, 110 2.1-12

THERMAL POWER LEVEL,%

M = 0.755

(-10.5,108.0)

(16.5,108.0)

M2= -1.89 ACCE 'TABLE 4 1 PUMP C PE RATION1 II-100

(-33.5,90.6)

(-10.51,80.6)

(16.5t,80.6)

(33.5,75.9) 0CCEPT ABLE 3 & 4 IPUMP C PE RATION

(-33.5,63.2).

I-60

(-10.51,52.9)

(16.5152.9)

APCEPT BLE 2,3, &

" (33.5,48.5)

PUMP CPERATIONI 1

40

(-33.5,35.5)

.1 I

20 (33.5,20.8)

I I

.I

-60

-40

-20 20 40 60 REACTOR POWER IMBALANCE,%

PROTECTIVE SYSTEM MAXIMUM ALLOWABLE SETPOINTS UNIT 3 OCONEE NUCLEAR STATION Figure 2.3-2C Amendments Nos.

114 113 &110 2-3-10

Bases The high pressure injection system and chemical addition system provide con trol of the reactor coolant system boron concentration.(1)

This is normally accomplished by using any of the three high pressure injection pumps in series with a boric acid pump associated with either the boric acid mix tank or the concentrated boric acid storage tank. An alternate method of boration will be the use of the high pressure injection pumps taking suction directly from the borated water storage tank.(2)

The quantity of boric acid in storage in the concentrated boric acid storage tank or the boralted water storage tank is sufficient to borate the reactor coolant system to a 1% Ak/k subcritical margin at cold conditions (700 F) with the maximum worth stuck rod and no credit for xenon at the worst time in core life. The current cycles for each unit were analyzed with the most limiting case selected as the basis for all three units. Since only the present cycles were analyzed, the specifications will be re-evaluated with each reload.. A minimum of 1020 ft3 of 8,700 ppm boric acid in the concentrated boric acid storage tank, or a minimum of 350,000 gallons of 1835 ppm boric acid in the borated water storage tank (3) will satisfy the requirements. The volume re quirements include a 10% margin and, in addition, allow for a deviation of 10 EFPD in the cycle length. The specification assures that two supplies are available whenever the reactor is critical so that a single failure will not prevent boration to a cold condition. The required amount of boric acid can be added in several ways. Using only one 10 gpm boric acid pump taking suction from the concentrated boric acid storage tank would require approximately 12.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> to inject the required boron. An alternate method of addition is to inject boric acid from the borated water storage tank using the makeup pumps.

The required boric acid can be injected in less than six hours using only one of the makeup pumps.

The concentration of boron in the concentrated boric acid storage tank may be higher than the concentration which would crystallize at ambient conditions.

For this reason, and to assure a flow of boric acid is available when needed, these tanks and their associated piping will be kept at least 100 F above the crystallization temperature for the concentration present. The boric acid concentration of 8,700 ppm in the concentrated boric acid storage tank cor responds to a crystallization temperature of 770 F and therefore a temperature requirement of 870F. Once in the high pressure injection system, the concen trate is sufficiently well mixed and diluted so that normal system temperatures assure boric acid solubility.

REFERENCES (1) FSAR, Section 9.1; 9.2 (2) FSAR, Figure 6.2 (3) Technical Specification 3.3 Amendments Nos. 113, 113, & 110 3.2-2

f.

If the maximum positive quadrant power tilt exceeds the Maximum Limit of Table 3.5-1, the reactor shall be shut down within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

Subsequent reactor operation is permitted for the purpose of measurement, testing, and corrective action provided the ther mal power and the Nuclear Overpower Trip Setpoints allowable for the reactor coolant pump combination are restricted by a reduc tion of 2% of thermal power for each 1% tilt for the maximum tilt observed prior to shutdown.

g.

Quadrant power tilt shall be monitored on a minimum frequency of once every 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> during power operation above 15% full power.

3.5.2.5 Control Rod Positions

a.

Technical Specification 3.1.3.5 does not prohibit the exercising of individual safety rods as required by Table 4.1-2 or apply to inoperable safety rod limits in Technical Specification 3.5.2.2.

b.

Except for physics tests, operating rod group overlap shall be 25% t 5% between two sequential groups.

If this limit is ex ceeded, corrective measures shall be taken immediately to achieve an acceptable overlap. Acceptable overlap shall be attained within two hours or the reactor shall be placed in a hot shutdown condition within an additional 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

c.

Position limits are specified for regulating and axial power shaping control rods. Except for physics tests or exercising control rods, the regulating control rod insertion/withdrawal limits are specified on figures 3.5.2-lAl, 3.5.2-1A2, and 3.5.2-1A3 (Unit 1); 3.5.2-IBI, 3.5.2-1B2, and 3.5.2-1B3 (Unit 2); 3.5.2-1C1, 3.5.2-1C2, and 3.5.2-1C3 (Unit 3) for four pump operation, on figures 3.5.2-2A1, 3.5.2-2A2, and 3.5.2-2A3 (Unit 1); 3.5.2-2B1, 3.5.2-2B2, and 3.5.2-2B3 (Unit 2); figures 3.5.2-2C1, 3.5.2-2C2, and 3.5.2-2C3 (Unit 3) for three pump operation, and on figures 3.5.2-2A4, 3.5.2-2A5, and 3.5.2-2A6 (Unit 1); 3.5.2-2B4, 3.5.2-2B5, and 3.5.2-2B6 (Unit 2); figures 3.5.2-2C4, 3.5.2-2C5, and 3.5.2-2C6 (Unit 3) for two pump operation. Also, excepting physics tests or exercising control rods, the axial power shaping control rod insertion/withdrawal limits are specified on figures 3.5.2-4A1, 3.5.2-4A2, and 3.5.2-4A3 (Unit 1); 3.5.2-4B1, 3.5.2-4B2, and 3.5.2-4B3 (Unit 2); 3.5.2-4C1, 3.5.2-4C2, and 3.5.2-4C3 (Unit 3).

If the control rod position limits are exceeded, corrective measures shall be taken immediately to achieve an acceptable control rod position. An acceptable control rod positiontshall then be attained within two hours. The minimum shutdown margin required by Specification 3.5.2.1 shall be maintained at all times.

Amendments Nos.

11

113,

& 110 3.5-9

Power Level (300,102) 100-(150.102)

CUTOFF 100% F P 8,.1 (27592) 802 SHUTDOWN (270,80)

MARGIN LIMIT RESTRICTED OPERATION

.60 UNACCEPTABLE OPERATION (90,50)

(200,50)

.40 ACCEPTABLE OPERATION 20 (40,15)

(90,15)

(0,1) 0 50 100 150 200 250 300 ROD INDEX.%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 BANK 6 0

25 50 75 100 BANK 7 ROD POSITION LIMITS FOR FOUR-PUMP OPERATION FROM 0 TO 50 (+10, -0) EFPD UUNIT 3 DUpwrw OCONEE NUCLEAR STATION Figure 3.5.2-ICI Amendments Nos.

113,

113& 110 3.5-17

POWER LEVEL (275,102 (300,1021 CUTOFF*100% FP SHUTDOWN (260.92)

MARGIN LIMIT RESTRICTED OPERATION UNACCEPTABLE

60.

OPERATION (90,50)

(200,50)

ACCEPTABLE OPERATION 20 (40,15)

(90,15) 0.10) 0.5)

(0,1 0

50 100 150 200 250 300 ROD INDEX.%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 SANK 6 0

25 50 75 100 BANK 7 ROD POSITION LIMITS FOR FOUR-PUMP 'OPERATION FROM 50 (+10, -0) TO 200 (+10) EFPD UNIT 3 POWE OCONEE NUCLEAR STATION Figure 3.5.2-1C2 Amendments Nos.

113, 113, &110 3.5-17a

POWER LEVEL CUTOFF=100% FP (300,102)

(220102)(275102) 100 (26092) 80.

(250,80)

RESTRICTED UNACCEPTABLE OPE RATION OPERATION 60 (160,50)

(200,50)

C L) 40 SHUTDOWN ACCEPTABLE MARGIN OPERATION LIMIT 20 (100,15) 0.5) 0 50 100 150 200 250 300 ROD INDEX,%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 BANK6 0

25 50 75 100 BANK7 ROD POSITION LIMITS FOR FOUR-PUMP OPERATION AFTER 200 (+10) EFPD UNIT 3 OCONEE NUCLEAR STATION Figure 3.5.2-1C3 Amendments Nos.

113, 113

, & 110 3.5-17b

100 80 (130377) 60 UNACCEPTABLE o

OPERATION RESTRICTED (90,50)

OPERATION (200.50) 0

~40 SHUTDOWN MARGIN ACCEPTABLE LIMIT OPERATION 20 (30,15)

(90,15)

(0,10)

(0,5) 0~

0 50 100 150 200 250 300 ROD INDEX,%WD 0

25 50 75 100 BANKS 0

25 50 75 100 BANK6 0

25 50 75 100 I

I

  • I BANK7 ROD POSIT!ON LIMITS FOR THREE-PUMP OPERATION FROM 0 TO 50 (+10, -0) EFPD UNIT 3 2KPoown; OCONEE NUCLEAR STATION Figure 3.5.2-2CI Mendments Nos.

113, 113, & 110 3.5-20

100 (130,77)

(245,77)

(300,77)

UNACCEPTABLE OPERATION RESTRICTED 0

(OPERATION (90,50)

(0,0 O

S40 SHUTDOWN MARGIN LIMIT ACCEPTABLE OPERATION 20 (30,15)

(90,.15)

(0,10)t (0,5) 0 50 100 150 200 250 3<)

ROD INDEX,%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 BANK6 0

25 50 75 100 BANK7 ROD POSITION LIMITS FOR THREE-PUMP OPERATION FROM 50 (+10,

-0)

TO 200 +10 EFPD UNIT 3 OCONEE NUCLEAR STATION Figure 3.5.2-2C2 Amendments Nos. 113, 113, &110 3.5-20a

100 RESTRICTED

/OPERATION (2 10.w7 (2577)

(300,77) 60 U

(160,50)

UNACCEPTABLE (200,50)

OPERATION S40 LU SHUTDOWN ACCEPTABLE MARGIN OPERATION LIMIT 20 (100, 15)

(0.5h 0

50 100 150 200 250 300 ROD INDEX.%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 BANK 6 0

25 50 75 100 BANK 7 ROD POSITION LIMITS FOR THREE-PUMP OPERATION AFTER 200 t10 EFPD UNIT 3 noow~it OCONEE NUCLEAR STATION Figure 3.5.2-2C3 Amendments Nos. 113, 113, & 110 3.5-20b

100*

0o 60 (205,52)

(300.52)

(80.52)

(200,50) 40 SHUTDOWNRESTRICTED MARGIN ACCEPTABLE LIMIT OPERATION 20 UNACCEPTABLE OPERATION (50,15)

(90,15)

(0.10)<

(0.5) 0 0

50 100 150 200 250 300 ROD INDEX.%WD 0

25 50 75 100 BANK 5 0

25 50 75 100 BANKAN 0

25 50 75 100 BANK 7 ROD POSTION LIMITS FOR TWO-PUMP OPERATION FROM 0 TO 50 (+10, -0) EF O UNIT 3 Ou[PwER OCONEE NUCLEAR STATION Ficure 3.5.2-2C Amendnents Nos.

113,113, &110 3520

100 804 (203,52)

(300.52)

(80,52)

(200,50) 40 a

SHUDOWN RESTRICTED SHUTDOWN OPERATION ACCEPTABLE MARGIN ACPAL LIMIT OPERATION 20-UNACCEPTABLE OPERATION (015 (0.10)

(0,5)<

0 50 100 150 200 250 300 ROD INDEX.%WD 0

25 50 75 100 BK 5

BANK 5 0

25 50 75 100 BANK 6 0

25 50 75 100 BANK 7 ROD POSITION LIMITS FOR TWO-PUMP OPERATION FROM 50 (+10, -0) TO 200 +/-10 EFPD UNIT 3 o

OCONEE NUCLEAR STATION Figure 3.5.2-2'5 Amendments Nos. 113, 113, & 110

100 80 RESTRICTED 6D -

OPERATION (170,52)

(203.52)

(300,52 UNACCEPTABLE (200,50i c

OPERATION

~4C SHUTDOWN ACCEPTABLE MARGIN OPERATION LIMIT.

20*\\

(0,5)<

0i 50 100 150 200 250 300 ROD INDEX,%WO 0

25 50 75 100 BANK 5 0

25 50 75 100 BANK 6 0

25 50 75 100 BANK 7 ROD POSITION LIMITS FOR TWO-PUMP OPERA.T ION AFTER 200 -t10 EFPD.

UN IT 3

'DUEownI11 OCONEE NUCLEA^R STATION Figure 3.5c.2--2C6 Amendments 1N0s.113.113

& 110 3.5-20e

REACTOR POWER,%FP

(-22.2,102.0)

(25.0,102.0) 100

(-24.5,92.0)

ACCEP ABLE (30.0,92.0)

OPERATION

(-30.0,80.0) 80 60 RESTRICTED OPERATION RESTRICTED OPERATION 40 20

-100

-80

-60

-40

-20 0

20 40 60 80 100 IMBALANCE,%

OPERATIONAL POWER IMBALANCE ENVELOPE FROM 0 TO 50 (+10, -0) EFPD UNIT 3 ourw OCONEE NUCLEAR STATION Figure 3.5.2-3d1 Amendments Nos.

11 113,

&110 3.5-23

REACTOR POWER,%FP

(-28.3,102.0) o (25.0,102.0)

ACCEPfABLE

(-30.0,92.0)

A C

AL (30.0,92.0)

OPERATION so 60 RESTRICTED OPERATION RESTRICTED OPERATION

-40 20

-100

-80

-60

-40

-20 0

20 40 60 80 100 IMBALANCE,%

OPERATIONAL POWER IMBALANCE ENVELOPE FROM 50 (+10, -0) TO 200 t10 E7PD UNI1T 3 tit oIwE)

OCONEE NUCLEAR STATION Figure 3.5.2-3C2 Amendments Nos.113,113, & 110 3.5-23a

REACTOR POWER,%FP

(-30.0,102.0)

(25.0,102.0) 100

(-35.0,92.0)

ACCE ABLE (30.0,92.0)

OPER TION 80 60 RESTRICTED OPERATION RESTRICTED OPERATION 40 20

-100

-80

-60

-40

-20 0

20 40 60 80 100 IMBALANCE,%

OPERATIONAL POWER IMBALANCE ENVELOPE AFTER 200 +/-10 EFPD UNIT 3 aLro

?OR OCONEE NUCLEAR STATION Figure 3.5.2-3C)

Amendments Nos.113, 113, & 110 3.5-23b

10010,102

/(r.400102 (6.0,92) 80 -(0.80)

(40,80)

RESTRICTED OPERATION 60 -(60,60)

ACCEPTABLE OPERATION 20 0

20 40 60 80 100 APSR POSITION,%WD APSR POSITION LIMITS FOR OPERATION4 FROM 0 TO 200 +10 EFPD UNIT 3 OUKIpowu OCONEE NUCLEAR STATION rFigure 3.5.2-nc]

Amendments Nos.

113, 113, &110 3.5-26

10(10.0, 102)

-(39.0, 102) 100 RESTRICTED OPERATION 60 (60,60)

S60 ACCEPTABLE OPERATION (100,40) 20 0*

0 20 40 60 80 100 APSR POSITION,%WD APSR POSITIO4 L!MITS FOR OPERATION AFTER 200 +10 EFPD

'UKroPw i OCONEE NUCLEAR STATION Figure 3.5.2-4c2 Amendments Nos.

113, 113, & 110 3.5-26a

Figure 3.5.2-4c3 Deleted during Oconee Unit 3, Cycle 7 Operation Amendments Nos.113 113, & 110 3.5-26b