November 20, 19980 Mr. William R. McCollum, Jr.

Vice President, Oconee Nuclear Site Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3, LICENSE RENEWAL APPLICATION

Dear Mr. McCollum:

By letter dated July 6, 1998, Duke Energy Corporation (Duke) submitted for the U.S. Nuclear Regulatory Commission's (NRC's) review an application pursuant to 10 CFR Part 54, to renew the operating licenses for the Oconee Nuclear Station (Oconee), Units 1, 2, and 3. Exhibit A to the application is the Oconee Nuclear Station License Renewal Technical Information Report (OLRP-1001), which contains the technical information required by 10 CFR Part 54. The NRC staff is reviewing the information contained in OLRP-1001 and has identified, in the enclosure, areas where additional information is needed to complete its review. Specifically, the enclosed questions are from the Reactor Systems Branch regarding Section 1.5.2 of OLRP-1001.

Please provide a schedule by letter, electronic mail, or telephonically for the submittal of your responses within 30 days of the receipt of this letter. Additionally, the staff would be willing to meet with Duke prior to the submittal of the responses to provide clarifications of the staff's requests for additional information.

Sincerely, original signed by:

PDR ADOCK 05000269 k Joseph M. Sebrosky, Project Manager P

License Renewal Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosure:

Request for Additional Information cc w/encl: See next page DISTRIBUTION: See next page

\\a DOCUMENT NAME:G:\\SEBROSKY\\RAI13.WPD OFFICE LA PM:PDLR PDLR:D NAME LBerry JSebrosky:sg ClGrimes DATE 11/)q /98 11/1(1/98 11/

/98 Z

OFFICIAL RECORD COPY

DISTRIBUTION: Hard copy Docket File PUBLIC PDLR RF JSebrosky M. EI-Zeftawy ACRS T2E26 E-mail; F. Miraglia C. Jackson J.Roe D. Matthews C. Grimes T. Essig G. Lainas J. Strosnider G. Bagchi H. Brammer T. Hiltz G. Holahan S. Newberry C. Gratton L. Spessard R. Correia R. Latta J. Peralta J. Moore R. Weisman M. Zobler E. Hackett A. Murphy T. Martin D. Martin W. McDowell S. Droggitis PDLR Staff M. Banic G. Hornseth H. Berkow D. LaBarge L. Plisco C. Ogle R. Trojanowski M. Scott C. Julian R. Architzel J. Wilson R. Wessman E. Sullivan R. Gill, Duke D. Walters, NEI

Oconee Nuclear Station (License Renewal) cc:

Paul R. Newton, Esquire Duke Energy Corporation Mr. J. E. Burchfield 422 South Church Street Compliance Manager Mail Stop PB-05E Duke Energy Corporation Charlotte, North Carolina 28201-1006 Oconee Nuclear Site P. 0. Box 1439 J. Michael McGarry, Ill, Esquire Seneca, South Carolina 29679 Anne W. Cottingham, Esquire Winston and Strawn Ms. Karen E. Long 1400 L Street, NW.

Assistant Attorney General Washington, DC 20005 North Carolina Department of Justice P. O. Box 629 Mr. Rick N. Edwards Raleigh, North Carolina 27602 Framatome Technologies Suite 525 L. A. Keller 1700 Rockville Pike Manager - Nuclear Regulatory Licensing Rockville, Maryland 20852-1631 Duke Energy Corporation 526 South Church Street Manager, LIS Charlotte, North Carolina 28201-1006 NUS Corporation 2650 McCormick Drive, 3rd Floor Mr. Richard M. Fry, Director Clearwater, Florida 34619-1035 Division of Radiation Protection North Carolina Department of Senior Resident Inspector Environment, Health, and U. S. Nuclear Regulatory Commission Natural Resources 7812B Rochester Highway 3825 Barrett Drive Seneca, South Carolina 29672 Raleigh, North Carolina 27609-7721 Regional Administrator, Region II Gregory D. Robison U. S. Nuclear Regulatory Commission Duke Energy Corporation Atlanta Federal Center Mail Stop EC-12R 61 Forsyth Street, SW, Suite 23T85 P. 0. Box 1006 Atlanta, Georgia 30303 Charlotte, North Carolina 28201-1006 Virgil R. Autry, Director Robert L. Gill, Jr.

Division of Radioactive Waste Management Duke Energy Corporation Bureau of Land and Waste Management Mail Stop EC-12R Department of Health and P. 0. Box 1006 Environmental Control Charlotte, North Carolina 28201-1006 2600 Bull Street RLGILL@DUKE-ENERGY.COM Columbia, South Carolina 29201-1708 Douglas J. Walters County Supervisor of Oconee County Nuclear Energy Institute Walhalla, South Carolina 29621 1776 I Street, NW Suite 400 Washington, DC 20006-3708 Chattooga River Watershed Coalition DJW@NEI.ORG P. 0. Box 2006 Clayton, GA 30525

REQUEST FOR ADDITIONAL INFORMATION OCONEE NUCLEAR STATION, UNITS 1. 2. AND 3 LICENSE RENEWAL APPLICATION, EXHIBIT A OLRP-1001 Section No.

1.5.2 Generic Safety Issue 23 - Reactor Coolant Pump Seal Failures 1.5.2-1 The application states that an aging management review is not required for the reactor coolant pump seals because they are generally replaced "approximately every four operating cycles" or "approximately every two operating cycles" depending on the component. The license renewal rule allows a component to be eliminated from an aging management review if it is subject to periodic replacement, based on a qualified life or a specified time period. Please describe the controlled replacement program which establishes a specific replacement frequency or interval (or upper limit replacement interval), based on a qualified life or a specified time period.

Enclosure