UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 17, 1998 Mr. W. R. McCollum, Jr.
Vice President, Oconee Site Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679
SUBJECT:
THIRD 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN REQUEST FOR RELIEF NO. 98-01 FOR OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (TAC NOS. MA1334, MA1335, AND MA1336)
Dear Mr. McCollum:
By letter dated March 25, 1998, Duke Energy Corporation (Duke) submitted Request for Relief No. 98-01, seeking relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (ASME Code)Section XI to take credit for limited ultrasonic examinations on the Pressurizer-to-Head weld and specific Letdown Cooler Heat Exchanger Nozzle-to-Vessel welds. Duke found that the examination coverage of the subject Unit 1 welds did not meet the 90 percent examination requirements of the Code and, for all three units, achievement of greater than 90 percent examination coverage for these welds is impractical.
Based on the information provided, the staff and its contractor, the Idaho National Engineering and Environmental Laboratory, concluded that certain inservice examinations are impractical to perform to the extent required by the ASME Code at Oconee Nuclear Station, Units 1, 2, and 3.
As explained in the enclosed Safety Evaluation and Technical Letter Report (as part of and attached to the Safety Evaluation), the staff has concluded that pursuant to Title 10 of the Code of Federal Regulations, Section 50.55a(g)(6)(i) relief is granted for Relief Request No. 98-01.
The licensee has submitted this request for Units 1, 2, and 3; however, only the Unit 1 examinations have been completed to-date. The licensee expects similar limitations and results to apply to the volumetric examinations performed on the same welds for Units 2 and 3.
PR A
030314 9117 PDR ADOCK 05000269 G
PUR ILE C N7 EE
W. R. McColum, Jr.
- 2 If the coverages achieved ard the same or more conservative (greater coverage), no further action is required. However, if the coverage is less than reported in this request, a new request for relief must be submitted.
Sincerely, bert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects - I/Il Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/encl: See next page
0 W. R. McCollum, Jr. November 17, 1998 If the coverages achieved are the same or more conservative (greater coverage), no further action is required. However, if the coverage is less than reported in this request, a new request for relief must be submitted.
Sincerely, ORIGINAL SIGNED BY:
Herbert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/ehcl: See next page Distribution:
e-mail TLH-3 (SE only)
COgle, Ril Docket File GHilI (6)
HBerkow PUBLIC ACRS LBerry PD 11-2 Rdg.
MTschiltz, EDO DLaBarge JZwolinski LPlisco, RII Document Name:
G:\\OCONEE\\OCOA2013.RR To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE PDII 2/
PDII-2/
- PK NAME DLa
- cn LBerry CHBe DATE I 5'/98 I)
/98
/198
///1/98 OFFICIAL RECORD COPY
Oconee Nuclear Station cc:
Mr. Paul R. Newton Mr. J. E. Burchfield Legal Department (PBO5E)
Compliance Manager Duke Energy Corporation Duke Energy Corporation 422 South Church Street Oconee Nuclear Site Charlotte, North Carolina 28201-1006 P. 0. Box 1439 Seneca, South Carolina 29679 J. Michael McGarry, III, Esquire Winston and Strawn Ms. Karen E. Long 1400 L Street, NW.
Assistant Attorney General Washington, DC 20005 North Carolina Department of Justice Mr. Rick N. Edwards P. 0. Box 629 Framatome Technologies Raleigh, North Carolina 27602 Suite 525 1700 Rockville Pike L. A. Keller Rockville, Maryland 20852-1631 Manager - Nuclear Regulatory Licensing Manager, LIS "Duke Energy Corporation, NUS Corporation 526 South Church Street 2650 McCormick Drive, 3rd Floor Charlotte, North Carolina 28201-1006 Clearwater, Florida 34619-1035 Mr. Richard M. Fry, Director Senior Resident Inspector Division of Radiation Protection U. S. Nuclear Regulatory North Carolina Department of Commission Environment, Health, and 7812B Rochester Highway Natural Resources Seneca, South Carolina 29672 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Regional Administrator, Region II U. S. Nuclear Regulatory Commission Mr. Steven P. Shaver Atlanta Federal Center Senior Sales Engineer 61 Forsyth Street, S.W., Suite 23T85 Westinghouse Electric Company Atlanta, Georgia 30303 5929 Carnegie Blvd.
Suite 500 Virgil R. Autry, Director Charlotte, North Carolina 28209 Division of Radioactive Waste Management Bureau of Land and Waste Management Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201-1708 County Supervisor of Oconee County Walhalla, South Carolina 29621