Text
CATEGORY 2
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9804020369
DOC.DATE: 98/03/25 NOTARIZED: NO
DOCKET #
FACIL:50-269 Oconee Nuclear Station, Unit 1, Duke Power Co.
05000269
50-270 Oconee Nuclear Station, Unit 2, Duke Power Co.
05000270
- 50-287
Oconee Nuclear Station, Unit 3, Duke Power Co.
05000287
AUTH.NAME.
AUTHOR AFFILIATION
JAUDON,J.P.
Region 2 (Post 820201)
RECIP.NAME
RECIPIENT AFFILIATION
MCCOLLUM,W.R.
Duke Power Co.
C
SUBJECT: Forwards insp repts 50-269/98-04,50-270/98-04 & 50-287/98-04
on 980302-05 & notice of violation.
A
DISTRIBUTION CODE: IE01F COPIES RECEIVED:LTR j
ENCL
SIZE: 4/7t 3
T
TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response
E
NOTES:
G
RECIPIENT
COPIES
RECIPIENT
COPIES
ID CODE/NAME
LTTR ENCL
ID CODE/NAME
LTTR ENCL
0
PD2-2 PD
1
1
LABARGE,D
1
1
R
INTERNAL: ACRS
2
2
AEOD/SPD/RAB
1
1
AEOD/T.,.C-
1
1
DEDRO
1
1
Y
'ENpTER<
1
1
NRR/DRCH/HHFB
1
1
NRR/DRPM/PECB
1
1
NRR/DRPM/PERB
1
1
NUDOCS-ABSTRACT
1
1
OE DIR
1
1
2
OGC/HDS2
1
1
RGN2
FILE
01
1
1
O
ERNAL: LITCO BRYCE,J H
1
1
NOAC
1
1
NRC PDR
1
1
NUDOCS FULLTEXT
1
1
D
0
C
U
M
E
LOADEDFROM
NRC FLOPPY
N
T
NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE.
TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS
O
OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION,
CONTACT THE DOCUMENT CONTROL
DESK (DCD) ON EXTENSION 415-2083
TOTAL NUMBER OF COPIES REQUIRED: LTTR
19
ENCL
19
March 25, 1998
Duke Energy Corporation
ATTN:
Mr. W. R. McCollum
Vice President
Oconee Site
P. 0. Box 1439
Seneca, SC 29679
SUBJECT:
NRC INSPECTION REPORT 50-269/98-04, 50-270/98-04, AND 50-287/98-04
Dear Mr. McCollum:
The refers to the inspection conducted on March 2-5, 1998, at your Oconee
facility. The enclosed report presents the results of that inspection.
Areas examined during the inspection are identified in the report. Within
these areas, the inspection consisted of selective examinations of procedures
and representative records, interviews with personnel, and observation of
activities in progress.
.
Based on the results of this inspection, a repeat violation of NRC
requirements was identified and is cited in the enclosed Notice of Violation
(Notice). The circumstances surrounding the violation are described in detail
in the enclosed report. The violation is of concern because it is a repeat of
a problem involving failure to secure Safeguards Information.
Please note you are required to respond to this letter and should follow the
instructions specified in the enclosed Notice when preparing your response.
The NRC will use your response, in part, to determine whether further
enforcement action is necessary to ensure compliance with regulatory
requirements.
Repetitive violations are addressed in the NRC's "Statement of Policy and
Procedure for NRC Enforcement Actions," (Enforcement Policy), NUREG-1600
Section IV.B. The Enforcement Policy allows the severity level of a violation
to be increased if the violation can be considered repetitive. For example, a
Severity Level IV violation could be increased to Severity Level III with the
attending escalated enforcement action. However, in this case, we have
decided not to increase the severity level of the violation because of the
immediate corrective action that was taken, the low safety significance and
your overall satisfactory performance in this area.
9804020369 980325
PDR ADOCK 05000269
G
2
According to 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this
letter, and its enclosures will be placed in the NRC Public Document Room
(PDR).
Sincerely,
Johns P. Jaudon. Director
Division of Reactor Safety
Docket Nos. 50-269. 50-270, 50-287
License Nos. DPR-38, DPR-47. DPR-55
Enclosure: 1. Notice of Violation
2. NRC Inspection Report Nos. 50-269/98-04, 50-270/98-04, AND
50-287/98-04
cc w/encls:
J. E. Burchfield
Compliance
.Duke
Energy Corporation
P. 0. Box 1439
Seneca, SC 29679
Paul R. Newton
Duke Energy Corporation
422 South Church Street
Charlotte, NC 28242-0001
Robert P. Gruber
Executive Director
Public Staff - NCUC
P. 0. Box 29520
Raleigh. NC 27626-0520
Robert B. Borsum
Framatome Technologies
1700 Rockville Pike, Suite 525
Rockville, MD 20852
(cc w/encls - See page 3)
3
.
(cc w/encls cont'd)
J. Michael McGarry, III, Esq.
Winston and Strawn
1400 L Street. NW
Washington, D. C. 20005
Mel Fry. Acting Director
Division of Radiation Protection
N. C. Department of Environmental
Health & Natural Resources
3825 Barrett Drive
Raleigh, NC 27609-7721
Max Batavia, Chief
Bureau of Radiological Health
S. C. Department of.Health and
Environmental Control
2600 Bull Street
Columbia, SC 29201
County Supervisor of
Oconee County
Walhalla, SC 29621
Manager, LIS
NUS Corporation
2650 McCormick Drive
Clearwater, FL 34619-1035
G. A. Copp
Licensing - EC050
Duke Energy Corporation
P. 0. Box 1006
Charlotte, NC 28201-1006
Karen E. Long
Assistant Attorney General
N. C. Department of Justice
P. 0. Box 629
Raleigh, NC 27602
Distribution w/encls:
D. LaBarge. NRR
R. Carroll. RII
Distribution w/encls cont'd - See page 4:
4
.
Distribution w/encls cont'd:
-C Payne, RII
PUBLIC
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
78128 Rochester Highway
Seneca, SC 29672
OFFICE
RII: RS
RII:DRP
RII: RS
\\
SIGNATURE
"'k,.
A
b
ws
COGLE /
GBE
__________
COM__L_
DATE
3/
/98
3/
/98
3/
/98
3/
4-/98
3/
VS
/98
3/
/98
3/
/98
COPY?
NO
S
NO
YES
NO
NO
YES
NO
YES
NO
YES
NO
OFFII
RECORD CO
NAME:
S:\\DRS\\SIB\\INPUTS\\OC098-04.WWS