MONTHYEARML15040A7202015-03-12012 March 2015 Request for Withholding Information from Public Disclosure for Peach Bottom Atomic Power Station, Unit No. 2 Project stage: Withholding Request Acceptance ML15083A5592015-03-24024 March 2015 Extended Power Uprate: Response to Replacement Steam Dryer Requests for Additional Information Project stage: Other ML15033A4892015-03-27027 March 2015 NRC Staff Review of Replacement Steam Dryer Re-Benchmarking to Support Extended Power Uprate Power Ascension Project stage: Approval ML15086A3332015-03-27027 March 2015 Request for Additional Information Regarding Replacement Steam Dryer Analysis, Exelon Generation Company, Llc. Peach Bottom Atomic Power Station - Unit 2 Project stage: RAI ML15096A0082015-04-0505 April 2015 Extended Power Uprate: Response to Replacement Steam Dryer Requests for Additional Information Project stage: Other ML15084A3422015-04-0606 April 2015 Request for Withholding Information from Public Disclosure for Peach Bottom Atomic Power Station, Unit No. 2 Project stage: Withholding Request Acceptance ML15099A7482015-04-0909 April 2015 Power Ascension Hold at 104% of 3514 Mwt Project stage: Other ML15110A0982015-04-10010 April 2015 E-Mail Peach Bottom Unit 2 - Power Ascension Hold at 104% of 3514 Mwt Project stage: Other ML15091A1342015-04-16016 April 2015 Summary of Closed Meeting Held on March 26, 2015, with Exelon Generation Company, LLC to Discuss Steam Dryer Analysis for Peach Bottom Atomic Power Station, Unit No. 2 Project stage: Meeting ML15125A1682015-04-25025 April 2015 Power Ascension - 108% Hold Point Decision Project stage: Other ML15127A5182015-05-0505 May 2015 Draft Request for Additional Information (Tac No. MF4792) Project stage: Draft RAI ML15127A5262015-05-0505 May 2015 Draft Request for Additional Information (Attachment 2) Project stage: Draft RAI ML15110A0852015-05-12012 May 2015 Request for Withholding Information from Public Disclosure for Peach Bottom Atomic Power Station, Unit No. 2 Project stage: Withholding Request Acceptance ML15135A4372015-05-15015 May 2015 Approval of Steam Dryer Methodology and Resumption of EPU Power Ascension Project stage: Other ML15135A4022015-05-15015 May 2015 Extended Power Uprate: Response to Replacement Steam Dryer Request for Additional Information Project stage: Request ML15127A2082015-05-19019 May 2015 Approval of Revision to Methodology for Establishing Replacement Steam Dryer Strain Limits Project stage: Other ML15196A6372015-07-15015 July 2015 Error Identified in Letter from Exelon to NRC Re Predicted Strain Ratios Provided in Response to Request for Additional Information (RAI-11) Project stage: Response to RAI 2015-04-05
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24250A1062024-09-0606 September 2024 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC - Fleet Request - Proposed Alternative to Utilize Code Case OMN-32 (L-2024-LLR-0030) ML24197A0162024-07-12012 July 2024 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC - Fleet Request - License Amendment Request to Adopt TSTF-591 ML24185A1782024-07-0303 July 2024 NRC Email Response to Peach Bottoms Request for Alternative Schedule to Complete Decommissioning Beyond 60 Years of Permanent Cessation of Operations ML24163A3522024-05-15015 May 2024 Meeting Feedback from May 14, 2024, Meeting with Constellation on Peach Bottom Atomic Power Station Units Nos. 2 and 3 ML24131A0612024-05-10010 May 2024 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Proposed Alternative to Utilize Code Case OMN-32 (L-2024-LLR-0030) ML24122B5072024-05-0101 May 2024 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-591, Revision 0 ML24088A3192024-03-28028 March 2024 Audit Plan Associated with Peach Bottom, Unit 1 - 10 CFR 50.82(a)(3) Alternate Decommissioning Schedule ML24002A7132023-12-29029 December 2023 Supplement - Peach Bottom Security Rule Exemption Request – ISFSI Docket No. Reference (EPID L-2023-LLE-0032) (Updated) (Email) ML23352A3242023-12-18018 December 2023 Acceptance of Requested Licensing Action Request for Alternative Schedule to Complete Decommissioning Beyond 60 Years of Permanent Cessation of Operations (EPID L- 2023-LLN-0004) ML23331A9112023-11-22022 November 2023 Supplement - Peach Bottom Security Rule Exemption Request – ISFSI Docket No. Reference ML23304A0182023-10-30030 October 2023 NRR E-mail Capture - Final RCI - Constellation Energy Generation, LLC - Peach Bottom 2 & 3 - Exemption from Security Rule (L-2023-LLE-0032) ML23264A7992023-09-21021 September 2023 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC – Fleet Request – License Amendment Request to Adopt TSTF-580, Revision 1 ML23237B3972023-08-24024 August 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative Request to Use Updated BWRVIP Guidelines ML23163A2292023-06-12012 June 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-580, Revision 1 ML22354A2622022-12-20020 December 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Request to Use Certain Provisions of the 2019 Edition of the ASME BPV Code, Section XI ML22325A0052022-11-18018 November 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-273-A, Revision 2 ML22200A0782022-07-19019 July 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request to Use Honeywell Mururoa V4F1 R Supplied Air Suits ML22118A3312022-04-28028 April 2022 NRR E-mail Capture - Peach Bottom - Formal RAI for Proposed Alternative I5R-14, Revision 1 ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22024A1852022-01-24024 January 2022 Acceptance for Review of Relief Request Associated with Reactor Pressure Vessel N-16A Nozzle Repair ML22020A0642022-01-13013 January 2022 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21301A0672021-10-28028 October 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-541 ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21252A0482021-09-0707 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21215A3502021-08-0303 August 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-554 ML21154A0132021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0112021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0142021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21134A0152021-05-14014 May 2021 Acceptance Ventilation Filter Testing LAR ML21117A0442021-04-26026 April 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21084A2532021-03-24024 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Transfer Application ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) ML21091A1782021-02-0202 February 2021 Ti 2515/194 Inspection Documentation Request ML21033A8552021-02-0202 February 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request to Expand the Use ASME Codes Cases N-878 and N-880 ML21012A1302021-01-12012 January 2021 Request for Additional Information - TSTF-505 ML20357A0972020-12-21021 December 2020 Request for Additional Information - TSTF-505 ML20350B5582020-12-14014 December 2020 NRR E-mail Capture - Exelon Generation Company, LLC -Alternative Request for Documentation of Replacement of Pressure Retaining Bolting ML20343A3492020-12-0707 December 2020 Acceptance of Requested Licensing Action: Peach Bottom Relief Request for N-16 Nozzle ML20324A6472020-11-19019 November 2020 Acceptance of Requested Licensing Action: Peach Bottom One-time Exemption App. B Sect. VI.C.3.(I)(1) Force on Force (COVID-19) ML20314A0282020-11-0606 November 2020 Verbal Relief for Penetration Nozzle ML20283A7722020-10-0909 October 2020 Submittal of Pennsylvania Letter Requesting Exemption from Biennial Exercise Requirements for Pennsylvania Nuclear Power Plants in Calendar Year 2020 ML20276A0762020-10-0202 October 2020 Acceptance of Requested Licensing Action, One-Time Acceptance for Review - Peach Bottom of Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements Due to COVID-19 Pandemic ML20266G3032020-09-22022 September 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Request to Use Paragraph IWA-5120 of the 2017 Edition of the ASME B&PV Code, Section XI ML20239A7982020-08-25025 August 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet License Amendment Request to Adopt TSTF-568, Revision 2 ML20217L3462020-08-0404 August 2020 Audit Plan Regarding License Amendment Request to Implement Riskinformed Extended Completion Times (L-2020-LLA-0120) ML20191A0182020-07-0101 July 2020 NRR E-mail Capture - Exelon Fleet RR for SPI for Appendix J Valves ML20178A1392020-06-26026 June 2020 Acceptance Review for Peach Bottom - License Amendment Request for TSTF-505 ML20153A7042020-06-0101 June 2020 NRR E-mail Capture - Preliminary RAI for Fleet Request to Use Alternative OMN-26 2024-09-06
[Table view] |
Text
From: Broaddus, Doug Sent: Friday, April 10, 2015 7:05 PM To: 'Scot.Greenlee@exeloncorp.com' Cc: Uhle, Jennifer; Evans, Michele; Lund, Louise; Wilson, George; Lubinski, John; Li, Yong; Manoly, Kamal; Basavaraju, Chakrapani; Bower, Fred; Barber, Scott; Hansell, Samuel; Smith, Brian; Modes, Michael; Ken Ainger; Ennis, Rick
Subject:
RE: Peach Bottom Unit 2 - Power Ascension Hold at 104% of 3514 MWt Mr. Greenlee, This email is a follow-up to the April 9, 2015, email from Mr. Rick Ennis (attached) which conveyed the results of NRCs review of the Peach Bottom Unit 2 steam dryer performance evaluations at 104% of 3514 MWt in accordance with license condition 2.C(15)(a).4.g, and our conference call with you this evening concerning our review of the additional performance information provided to the NRC earlier today.
As we discussed with you on the call, the NRC staff has determined that the additional performance information provides reasonable assurance regarding the structural integrity of the steam dryer up to 108% of 3514 MWt. Therefore, the NRC staff has no objection to the resumption of power ascension for PBAPS Unit 2 to the next hold point specified in license condition 2.C(15) (i.e., 108% of 3514 MWt). Further power ascension of PBAPS Unit 2 beyond 108% of 3514 MWt will be contingent upon continued demonstration of the structural integrity of the replacement steam dryer in accordance with the provisions in license condition 2.C(15).
In addition, during the call you agreed that Exelon will provide the following additional information no later than the date that the steam dryer evaluation, performed based on data collected at 108% of 3514 MWt, is provided to the NRC in accordance with license condition 2.C(15):
- 1. Exelon will provide the measured strain trending data for the non-MSLA frequency range (0-50 Hz), and MSLA frequency range (50-250 Hz) at 108% of 3514 MWt, analogous to the data provided in response to the NRC staff question #9 regarding the steam dryer evaluation performed based on data collected at 104% of 3514 MWt.
- 2. To provide further indication into the level of conservatism in Exelons revised methodology for the non-MSLA evaluation, Exelon will apply the approach discussed in RAI 10-S1 to a narrow frequency band (35 to 40 Hz) in the NMSL frequency range, and compare it with the corresponding results for the same narrow frequency range extracted from the response to RAI 10.
As we also discussed in the call, Rick Ennis will schedule an additional call with your staff early next week concerning RAI 10-S1.
Please let me know if you have any questions.
Doug Douglas A. Broaddus Chief, Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Phone: 301-415-8124; email: Doug.Broaddus@nrc.gov From: Ennis, Rick Sent: Thursday, April 09, 2015 4:14 PM To: Ken Ainger Cc: Uhle, Jennifer; Evans, Michele; Lund, Louise; Wilson, George; Broaddus, Doug; Lubinski, John; Ross-Lee, MaryJane; Li, Yong; Manoly, Kamal; Breach, Michael; Basavaraju, Chakrapani; Vik Shah; Stephen Hambric; Samir Ziada; Bower, Fred; Barber, Scott; Hansell, Samuel; Smith, Brian; Modes, Michael; David Neff; Rommel, John C.:(GenCo-Nuc); Kevin Borton (kevin.borton@exeloncorp.com)
Subject:
Peach Bottom Unit 2 - Power Ascension Hold at 104% of 3514 MWt Importance: High
- Ken, The NRCs letter dated March 27, 2015 (ADAMS Accession No. ML15033A489), approved the power ascension of Peach Bottom Unit 2 from 100% of 3514 MWt to 104% of 3514 MWt. As discussed in that letter, further power ascension beyond 104% of 3514 MWt will be contingent upon continued demonstration of the structural integrity of the steam dryer in accordance with the provisions in license condition 2.C(15). In addition, the staffs letter stated that additional information (detailed in the enclosure to the letter) needs to be provided to help inform the staffs decision on the acceptability of power ascension beyond 104% of 3514 MWt. This request for additional information (RAI-10) was provided in draft form to Exelon on March 19, 2015. In addition, the RAI was discussed during a meeting between Exelon and the NRC on March 26, 2015. The RAI pertained to Exelons request for NRC approval of a proposed change in the steam dryer analysis methodology as described in Exelons letter February 3, 2015, as supplemented by letter dated March 24, 2015 (ADAMS Accession Nos. ML15034A573 and ML15083A559, respectively). The request for NRC approval of the change in methodology is required in accordance with license condition 2.C(15)(d).
In my email dated April 6, 2015, at 8:02 am, I confirmed receipt of Exelons evaluations for the 104% of 3514 MWt hold point for the Peach Bottom Unit 2 power ascension. That email also confirmed receipt of Exelons letter dated April 5, 2015 (ADAMS Accession No. ML15096A007),
which provided a response to RAI-10 associated with the proposed change in the steam dryer analysis methodology dated February 3, 2015. The April 6, 2015 email started a 96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> period for NRC review of the 104% evaluations in accordance with license condition 2.C(15)(a).4.g.
On April 7, 2015, the NRC staff sent Exelon questions regarding the steam dryer evaluation at 104% as well as on the response to RAI-10 contained in Exelons April 5, 2015, letter. A call to clarify the staffs questions was held with Exelon on April 8, 2015. During the call, the staff expressed concerns regarding the response to RAI-10. These concerns relate to issues discussed in detail during the meeting with Exelon on March 26, 2015. In order to address
these concerns, the staff indicated that it needed Exelon to formally docket a response to a supplemental RAI question designated as RAI 10-S1.
Given that Exelons response to RAI-10 did not provide sufficient information to provide the NRC with reasonable assurance regarding the structural integrity of the steam dryer at higher power levels, the staff has determined that power ascension above 104% of 3514 MWt is not warranted at this time. The staff will reconsider this determination following submittal of the response to RAI 10-S1.
Please let me know if you have any questions.
- Thanks, Rick