- Entergy Enteray Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Tel (914) 254-6700 Lawrence Coyle Site Vice President NL-15-013 January 28, 2015 U.S. Nuclear Regulatory Commission Document Control Desk 11545 Rockville Pike, TWFN-2 F1 Rockville, MD 20852-2738
SUBJECT:
REFERENCES:
Re-Submittal of NETCO Report NET-300067-01, "Criticality Safety Analysis of the Indian Point Unit 2 Spent Fuel Pool with Credit for Inserted Neutron Absorber Panels," for NRC Review and Approval Indian Point Nuclear Generating Unit No. 2 Docket No. 50-247 License No. DPR-26
- 1.
Entergy letter to NRC, "Submittal of NETCO Report NET-300067-01, "Criticality Safety Analysis of the Indian Point Unit 2 Spent Fuel Pool with Credit for Inserted Neutron Absorber Panels," for NRC Review and Approval Indian Point Nuclear Generating Unit No. 2," (NL 083) dated November 13, 2014
- 2.
NRC letter to Entergy, "Indian Point Nuclear Generating Unit No. 2 -
Supplemental Information Needed for Acceptance of Requested Licensing Action Re: Spent Fuel Pool Criticality Analysis," dated January 21, 2015
Dear Sir or Madam:
By letter dated November 13, 2014 (Reference 1), Entergy Nuclear Operations, Inc. submitted to the NRC copies of the Proprietary and Non-Proprietary versions of the NETCO document "Criticality Safety Analysis of the Indian Point Unit 2 Spent Fuel Pool with Credit for Inserted Neutron Absorber Panels." The criticality safety analysis, NET-300067-01 had been submitted for NRC review and approval prior to a future license amendment request (LAR).
On January 16, 2015, a telephone conference call between the NRC staff and representatives for Entergy was held. In accordance with LIC-109, the staff's reviewers performed an acceptance review of NET-300067-01 and identified concerns regarding the depletion code validation methodology used in the criticality safety analysis. Furthermore, the "Extended ISG-8" approach was not consistent with the guidance provided in DSS-ISG-2010-01 regarding depletion code validation. The NRC documented their acceptance review concerns in a letter to Entergy dated January 21, 2015 (Reference 2).
A0o/
NL-15-013 Docket No. 50-247 Page 2 of 2 Based upon the above, Entergy has determined that it will revise and re-submit the criticality safety analysis for NRC's review and approval. The revised criticality safety analysis will address the NRC's concerns regarding the depletion code validation methodology and will be provided no later than March 4, 2015.
There is a new commitment being made by Entergy in this submittal which is identified in the attachment to this letter.
If you have any questions or require additional information, please contact Mr. Robert W. Walpole, Regulatory Assurance Manager at (914) 254-6710.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on
/'Z Sincerely, iy LC/r/
Attachment:
List of Regulatory Commitments cc:
Mr. Daniel H. Dorman, Regional Administrator, NRC Region I Mr. Douglas Pickett, NRC, Sr. Project Manager, Division of Reactor Licensing Ms. Bridget Frymire, New York State Dept. of Public Service Mr. John B. Rhodes, President and CEO NYSERDA NRC Resident Inspector's Office
NL-15-013 Docket No. 50-247 Attachment Page 1 of 1 List of Regulatory Commitments The following table identifies those actions committed to by Entergy in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
TYPE (Check One)
SCHEDULED COMMITMENT ONE-CONTINUING COMPLETION DATE TIMENIN TIME COMPLIANCE (If Required)
ACTION Entergy will revise the IP2 SFP criticality safety analysis report (NET-300067-01) to address the NRC's concerns regarding the depletion
[/]
March 4, 2015 code validation methodology. The revised report will be provided to the NRC no later than March 4, 2015.