~Entergy GNRO-2014/00079 November 13,2014 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Entergy Operations, Inc.

P. O. Box 756 Port Gibson, MS 39150.

Kevin Mulligan Site Vice President Tel. (601) 437-7500

SUBJECT:

REFERENCES:

Dear Sir or Madam:

Request for Additional Information Regarding Request for Adoption of TSTF-423, Revision 1, Change In Technical Specification End States (CE-NPSD-1186)

Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29 1.

Letter: Grand Gulf Nuclear Station Unit 1, Application for Technical Specification Changes; Technical Specification Task Force (TSTF)

Improved Standard Technical Specification Change Traveler, TSTF-423, Technical Specification End States (GNRO-2013/00065)

(ML13316B024) 2.

NRC Electronic Letter: Grand Gulf Nuclear Station, Unit 1, Request for Additional Information Regarding Technical Specification Task Force Traveler (TSTF) - 423 (TAC No. MF3175) 3.

Letter: Grand Gulf Nuclear Station Unit 1, Request for Additional Information Regarding Request for Adoption of TSTF-423, Revision 1, Change In Technical Specification End States (CE-NPSD-1186)

(GNRO-2014/00067)

In Reference 1 Entergy Operations Inc. (Entergy) submitted a request for an amendment to the

\\

Technical Specifications (TS) for the Grand Gulf Nuclear Station (GGNS), Unit 1.

During the review of this request the Nuclear Regulatory Commission (NRC) identified the need to reference the commitments contained in the standard TSTF. As discussed, Entergy proposed to include the reference with the current listing of the License Conditions.

Currently the GGNS Operating License has 39 conditions on pages 4 through 16 of the document. Entergy proposes to add a new condition referencing the commitments required by the standard TSTF safety evaluation. This new commitment will be included in Updated Final Safety Analysis Report (UFSAR) Section 16, "Technical Specifications." The proposed license condition also includes the provision to evaluate changes to the commitment through the use of the 10 CFR 50.59 process.

GNRO-2014/00079 Page 2 of 2 The proposed changes to the Operating License are in Attachment 1. Attachment 2 contains the regulatory commitments in this letter.

If you have any questions or require additional information, please contact James Nadeau at 601-437-2103.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 13th day of November, 2014.

Sincerely,

~L KJM/ram'r'

~....J. ----")_----~

Attachments:

1. Proposed License Condition
2. Regulatory Commitment U.S. Nuclear Regulatory Commission ATIN: Mr. A. Wang, NRR/DORL Mail Stop OWFN/8 G14 11555 Rockville Pike Rockville, MD 20852-2378 NRC Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150 U. S. Nuclear Regulatory Commission ATIN: Marc L. Dapas (w/2)

Regional Administrator, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 to GNRO-2014/00079 Proposed License Condition

GNRO-2014/00079 Attachment 1 Proposed License Condition Commitments made as required by standard TSTF safety evaluation, as discussed in the notice of availability, will be maintained as described in UFSAR Section 16, Technical Specifications. This condition applies to the following TSTFs as approved.

TSTF-423 Changes to the commitments can be made in accordance with the 10 CFR 50.59 process.

to GNRO-2014/00079 Regulatory Commitment

GNRO-2014/00079 Attachment 2 List of Regulatory Commitment The following table identifies the action committed to by Entergy in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.

Type (Check One)

Scheduled Commitment One-Continuing Completion Time Date Action Compliance Commitments made as required by standard TSTF safety evaluation, as discussed Upon in the notice of availability, will X

Implementation be maintained as described in UFSAR Section 16, Technical Specifications.