ML14275A049
ML14275A049 | |
Person / Time | |
---|---|
Site: | Cook ![]() |
Issue date: | 08/01/2014 |
From: | Mcneil D NRC/RGN-III/DRS/OLB |
To: | Indiana Michigan Power Co |
References | |
Download: ML14275A049 (58) | |
Text
CONTROL ROOM JPM a Facility: DC Cook Task No: ______
Task
Title:
Place Hydrogen Recombiner in Service (ALTERNATE PATH)
Job Performance Measure No: CR JPM a K/A
Reference:
___028 A4.01___
Examinee: NRC Examiner: _____________________
Facility Evaluator: Date: _____________________________
Method of testing:
Simulated Performance _______________ Actual Performance ________X__________
Classroom ______________ Simulator _____X________ Plant __________
Task Standard: Place a hydrogen recombiner in service. The first one will not reach temperature and the second one must be placed in service.
Required Materials: 02-OHP-4023.-005, Placing Hydrogen Recombiners in Service.
General
References:
2-OHP 4030-214-031, Rev. 26, Operations Weekly Surveillance Checks, Read to the examinee:
Initial Conditions: The plant suffered a LOCA. All necessary mitigation actions per EOPs have been performed. Seven hours have elapsed since the onset of the LOCA. Hydrogen concentration in the containment is approximately 3%.
Initiating Cue: You are directed to place the hydrogen recombiners in service in accordance with 02-OHP-4023.-005, Placing Hydrogen Recombiners in Service.
Time Critical Task: No Validation Time: 20 Minutes
Appendix C Job Performance Measure Worksheet Standard: IT HAS BEEN 7 HOURS S CUE: If Required, IT HAS BEEN 7 HO LOCA SAT: UNSAT:
COMMENT:
Standard: CHECKS 600V BUSES 21B AND 21C ARE ENERGIZED, OR CHECKS LIGHTS (HR1 & HR2) ENE SAT: UNSAT:
COMMENT:
Standard: VERIFY CONTAINMENT R FANS RUNNING -CEQ FANS
- 2-HV-CEQ-1 RUNNING
- 2-HV-CEQ-2 RUNNING SAT: UNSAT:
COMMENT:
Appendix C Job Performance Measure Worksheet Standard: VERIFY DAMPERS OPEN SUCTION DAMPERS FOR RUNNIN
- 2-VMO-101 OPEN
- 2-VMO-102 OPEN SAT: UNSAT:
COMMENT:
Standard: VERIFY CEQ FAN CCW V
- 2-CCM-430 OPEN
- 2-CCM-431 OPEN
- 2-CCM-432 OPEN
- 2-CCM-433 OPEN SAT: UNSAT:
COMMENT:
Standard: VERIFY POWER ADJUST SAT: UNSAT:
COMMENT:
Standard: PLACE BOTH CONTROL RUN:2-HRI AND 2-HR2 CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: RAISE BOTH POWER AD OBTAIN 5 kW CRITICAL STEP SAT: UNSAT:
COMMENT:
Appendix C Job Performance Measure Worksheet Standard: MAINTAIN POWER AT 5 MINUTES (TIME COMPRESSION)
CUE: 10 Minutes Have Passed - Tem CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: RAISE POWER ADJUSTE kW MAINTAIN POWER AT 10 KW F (TIME COMPRESSION)
CUE: 10 Minutes Have Passed - Tem CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: RAISE ONE POWER ADJ 20 kW MAINTAIN POWER AT 20 kW (TIME COMPRESS)
CUE: 5 Minutes Have Passed - Tem CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: USING THE VALUE OF T PRESSURE (2.28 PSIG) THE APPLI THE HEATER POWER TARGET VA 1 OF SUP.005, PAGE 7 (HR1=67-67.5, HR2=58-58.5)
CRITICAL STEP SAT: UNSAT:
COMMENT:
Appendix C Job Performance Measure Worksheet Standard: APPLICANT ATTEMPTS ADJUSTER TO OBTAIN THE REQU ABOVE.
CRITICAL STEP SAT: UNSAT:
COMMENT:
NOTE: The Power Adjuster Knob wil the first recombiner to reach 23 KW PAGE Standard: APPLICANT DETERMINE REPEATED ADJUSTER WILL NOT FUNCTION T CRITICAL STEP SAT: UNSAT:
COMMENT:
NOTE: IF THE APPLICANT INFORM CANNOT RAISE KW TO THE DESIR THEM WHAT THEY RECOMMEND.
APPEAR NOT TO HAVE DETERMIN SECOND H2 RECOMBINER, CUE T RECOMBINER MUST BE PLACED I SAT: UNSAT:
COMMENT:
Standard: RAISE THE SECOND HY RECOMBINER POWER TO 20 kW A FOR 5 MINUTES (TIME COMPRESS CUE: 5 Minutes Have Passed - Tem CRITICAL STEP SAT: UNSAT:
COMMENT:
Appendix C Job Performance Measure Worksheet USING THE VALUE OF THE CONTA PRESSURE (2.28 PSIG) THE APPLI THE HEATER POWER TARGET VA 1 OF SUP.005, PAGE 7 THE SELECTED VALUE SHOULD B THAT SELECTED FOR THE FIRST (HR1=67-67.5, HR2=58-58.5)
CRITICAL STEP PAGE SAT: UNSAT:
REPEATED COMMENT:
Standard: RAISE POWER ADJUSTE REQUIRED POWER ABOVE, CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: LOG HYDROGEN CONC HYDROGEN RECOMBINER POWER ATTACHMENT A OF SUP.005, HYD RECOMBINER LONG-TERM MONIT SAT: UNSAT:
COMMENT:
Appendix C Job Performance Measure Worksheet Attached for Reference ONLY Based on 2.28 Psig in Containment HR1=67-67.5 HR2=58-58.5
CONTROL ROOM JPM b Facility: DC Cook Task No: ______
Task
Title:
Transfer to cold leg recirculation (Alternate Path)
Job Performance Measure No: ___CR JPM b K/A
Reference:
__EPE.011.EA1.11_
Examinee: NRC Examiner: _____________________
Facility Evaluator: Date: _____________________________
Method of testing:
Simulated Performance _______________ Actual Performance _______X_________
Classroom ______________ Simulator _____X_______ Plant __________
Task Standard: The operator will stop both trains of CTS and RHR, re-align the West train for recirculation flow, and secure spray additive tank flow Required Materials: 2-OHP-4023-ES-1.3 completed through step 5 General
References:
2-OHP-4023-ES-1.3 REV.16 Read to the examinee:
Initial Conditions: A reactor trip and safety injection have occurred on Unit 2 due to a large break LOCA. 2-OHP-4023-E-0. 2-OHP-4023-E-1, and 2-OHP-4023-ES-1.3 have been implemented. 2-OHP-4023-ES-1.3 has been completed through step 5. You are an extra RO.
Initiating Cue:
The US directs you to continue actions of 2-OHP-4023-ES-1.3, starting at step 6.
Report when step 6 is complete. You may review previously completed steps of 2-OHP-4023-ES-1.3 prior to starting the JPM.
Time Critical Task: Yes (PMP-4075-TCA-001 Attachment 1 & 29)
Validation Time: 15 MINUTES
CONTROL ROOM JPM b EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator stops East CTS pump and places control switch in lockout.
Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator stops East RHR pump and places control switch in lockout.
Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator verifies both pumps stopped.
SAT: UNSAT:
COMMENT:
NOTE: Step not critical due to failure of 2-ICM-305 to open.
STANDARD: Operator initiates valve closure for both valves SAT: UNSAT:
COMMENT:
EVALUATOR NOTE:
Mark time West CTS and RHR pumps are stopped to evaluate time critical action (Re-start RHR and CTS pumps within 5 minutes of stopping them for switchover to the containment recirculation sump).
TIME STANDARD: Operator stops West CTS pump and places control switch in lockout.
Critical Step SAT: UNSAT:
COMMENT:
CONTROL ROOM JPM b EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator stops West RHR pump and places control switch in lockout.
Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator verifies both pumps stopped.
SAT: UNSAT:
COMMENT:
STANDARD: CS Operator initiates valve closure for both valves Critical Step SAT: UNSAT:
COMMENT:
NOTE: Step not critical due to failure of 2-ICM-305 to open.
STANDARD: Operator restores control power to ICM-305 SAT: UNSAT:
COMMENT:
CONTROL ROOM JPM b EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
NOTE: Step not critical due to failure of 2-ICM-305 to open.
STANDARD: Operator verifies IMO-215 and IMO-310 are full closed before proceeding SAT: UNSAT:
COMMENT:
STANDARD: Operator attempts to open ICM-305 (unsuccessful) and transitions to step 6.n (does not start East RHR/CTS pumps)
Critical Step SAT: UNSAT:
COMMENT:
CONTROL ROOM JPM b EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator restores control power to ICM-306 Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator verifies IMO-225 and IMO-320 are full closed before proceeding Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator opens ICM-306 and verifies valve is full open Critical Step SAT: UNSAT:
COMMENT:
CONTROL ROOM JPM b EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator starts the West RHR and West CTS pump within 5 minutes of stopping the pumps Critical Step SAT: UNSAT:
COMMENT:
EVALUATOR: Record time that West RHR/CTS pumps are started:
TIME ______________
STANDARD: Operator resets the CTS actuation Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator closes IMO-202 and IMO-204 within 5 minutes of starting the pumps in recirculation lineup. (Att. 29)
Critical Step SAT: UNSAT:
COMMENT:
EVALUATOR: Record time that IMO-202 and IMO-204 are closed:
TIME ______________
STANDARD: Operator closes eductor supply valves Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator verifies the West RHR pump is running normally on the recirculation sump.
SAT: UNSAT:
COMMENT:
Terminating CUE: The JPM is complete.
CONTROL ROOM JPM c Facility: DC Cook Task No: ______
Task
Title:
Synchronize the Main Turbine Generator to the grid Job Performance Measure No: _CR JPM c_ K/A
Reference:
___045 A4.02__
Examinee: NRC Examiner: _____________________
Facility Evaluator: Date: _____________________________
Method of testing:
Simulated Performance _______________ Actual Performance _______X__________
Classroom ______________ Simulator _______X_____ Plant __________
Task Standard: The main turbine generator is synchronized to the grid.
Required Materials: 1-OHP-4021-050-001, Rev. 60, Turbine Generator Normal Startup and Operation Turbine Generator Normal Startup and Operation Steps 4.16.25 thru 4.16.30 General
References:
1-OHP-4021-050-001 Read to the examinee:
Initial Conditions: Unit 1 is performing a start-up. The turbine is at 1800 rpm and all of the preparations are completed for synchronizing to the grid. You are the extra RO.
Initiating Cue: You are directed to synchronize the main generator to the grid using 1-OHP-4021-050-001, Rev. 60, Turbine Generator Normal Startup and Operation, using AUTO starting on Step 4.16.25.
Time Critical Task: No Validation Time: 20 minutes Page 1 of 5
Appendix C Job Performance Measure Form ES-C-1 Worksheet EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
Standard: Switch is in Manual CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Raise turbine speed using the Speed and Load Changer until synchroscope is rotating slowly in the FAST direction.
SAT: UNSAT:
COMMENT:
Standard: Verify Bus Gen Line Frequency recorder indicates between 59.5 and 60.5 Hz.
SAT: UNSAT:
COMMENT:
Page 2 of 5
Appendix C Job Performance Measure Form ES-C-1 Worksheet EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
Standard: Adjust the Generator & Start Voltage 2 - 3 volts
> the Run & 345 kV Bus Voltage using the Generator Voltage Reg Manual Adjust.
SAT: UNSAT:
COMMENT:
Standard: Place the following Voltage Selector Switches in - OFF:
- Generator & Start
- Run & 345 kV Bus CRITICAL STEP SAT: UNSAT:
COMMENT:
NA Page 3 of 5
Appendix C Job Performance Measure Form ES-C-1 Worksheet EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
NA Standard: CB-O1 Synch Selector switch in - AUTO CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Place the CB-O1 control switch in - CLOSE CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Verify white "SYNCH PERMISSIVES MET" lamp - LIT SAT: UNSAT:
COMMENT:
Page 4 of 5
Appendix C Job Performance Measure Form ES-C-1 Worksheet EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
Standard: Verify CB O1 breaker is CLOSED SAT: UNSAT:
COMMENT:
Standard: Selector switch to - OFF CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Verify Generator Paralleled and MW rising to ~
50MW SAT: UNSAT:
COMMENT:
Standard: CB-O Synch Selector switch in - MAN CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Place the CB-O control switch in - CLOSE CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Place GEN SYNC MASTER CLOSE - CLOSE CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Verify CB O breaker is CLOSED SAT: UNSAT:
COMMENT:
Standard: Selector switch to - OFF SAT: UNSAT:
COMMENT Terminating cue: JPM IS COMPLETE Page 5 of 5
CONTROL ROOM JPM d Facility: DC Cook Task No: ______
Task
Title:
Fill ECCS Accumulator 1-2 Job Performance Measure No: _CR JPM d K/A
Reference:
_006 A1.13 _
Examinee: NRC Examiner: _____________________
Facility Evaluator: Date: _____________________________
Method of testing:
Simulated Performance _______________ Actual Performance _______X__________
Classroom ______________ Simulator ______X_______ Plant __________
Task Standard: The accumulator is filled to within Tech Spec requirements Required Materials: 1-OHP-4021-008-004, Rev. 20, ADJUSTING THE LEVEL OF AN ACCUMULATOR - Attachment 3 1-OHP-4023-008-007 Operation of the Safety Injection Pumps General
References:
1-OHP-4021-008-004 Read to the examinee:
Initial Conditions: ANNUNCIATOR #106 RESPONSE: RESIDUAL HEAT REMOVAL, DROP 17 is in alarm for Accumulator low level.
Initiating Cue: The Shift Manager has directed you to return the accumulator to the normal level in accordance with 1-OHP-4021-008-004, , ATTACHMENT 3 Rev. 20, ADJUSTING THE LEVEL OF AN ACCUMULATOR.
The Starting Team is standing by to start the South SI pump in accordance with 02-OHP-4021-008-007 and to assist with Local Operations.
Time Critical Task: No Validation Time: 20 Minutes Page 1 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
NOTE: Prerequisites has been verified as met Page 2 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Operator checks the #12 Accumulator box.
SAT: UNSAT:
COMMENT:
Standard: Operator verifies RCS pressure is greater than 1700 psig.
SAT: UNSAT:
COMMENT:
Standard: Operator verifies valve 1-ICM-265 is OPEN SAT: UNSAT:
COMMENT:
Page 3 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
(NOTE: Accumulator pressure regulation should NOT be required.)
Operator should mark step 4.4 as N/A with initial and date.
CUE: (If asked) Accumulator pressure control is NOT required at this time.
Page 4 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Operator reports that South SI pump is INOPERABLE CUE: US acknowledges South SI pump is INOPERABLE.
Standard: Operator directs AEO to CLOSE valve 1-SI-111S.
CRITICAL STEP NOTE: When the Aux Tour AEO is directed to CLOSE 1-SI-111S, then BOOTH Operator must enter MRF SIR13 to 0)
CUE: AEO reports 1-SI-111S is CLOSE SAT: UNSAT:
COMMENT:
NOTE: Provide a copy of 1-OHP 4021.008.007 to operator.
CUE: Local operator actions have been completed and verified.
Standard: Start South SI Pump CRITICAL STEP SAT: UNSAT:
COMMENT:
Page 5 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Operator reports that South SI pump is INOPERABLE CUE: US acknowledges South SI pump is INOPERABLE.
Operator directs AEO to CLOSE valve 1-SI-111S.
CUE: AEO reports valve 1-SI-111S is Already CLOSED.
Standard: Start South SI Pump CRITICAL STEP SAT: UNSAT:
COMMENT:
CUE: AEO has verified recirculation flow of 55 gpm within 5 seconds of start.
Page 6 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
CUE: AEO reports that all local indications are SAT for pump operation. {Vibration is lower than TDB 15.2 limits; lube oil pressure is
> 10 psig}
CUE: AEO reports local temperatures are NORMAL and NO excessive hot spots exist.
Operator returns to procedure in effect for raising Accumulator Level at Step 4.7.
Page 7 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Repeated Page Standard: Operator directs AEO to OPEN valve 1-SI-111S.
CRITICAL STEP NOTE: When the Aux Tour AEO is directed to OPEN 1-SI-111S, then BOOTH Operator must enter MRF SIR13 to 100)
CUE: AEO reports 1-SI-111S is OPEN SAT: UNSAT:
COMMENT:
Page 8 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Close IMO-270 SI Discharge Xtie CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Operator directs AEO to OPEN valve 1-IRV-60.
CRITICAL STEP NOTE: When the Aux Tour AEO is directed to OPEN 1-IRV-60, then BOOTH Operator must enter MRF U1_SIR21 to OPEN)
CUE: AEO reports 1-IRV-60 is OPEN SAT: UNSAT:
COMMENT:
CUE: STA will enter time and date of Tech Spec entry.
CUE: US directs you to fill the No. 2 Accumulator to 945 ft³ Standard: Open 1-IRV-121 CRITICAL STEP SAT: UNSAT:
COMMENT:
Page 9 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Close 1-IRV-121 CRITICAL STEP SAT: UNSAT:
COMMENT:
Page 10 of 11
CONTROL ROOM JPM d EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Operator directs AEO to CLOSE valve 1-IRV-60.
CRITICAL STEP NOTE: When the Aux Tour AEO is directed to CLOSE 1-IRV-60, then BOOTH Operator must enter MRF U1_SIR12 to CLOSE)
CUE: AEO reports 1-IRV-60 is CLOSED SAT: UNSAT:
COMMENT:
CUE: Independent verification has been performed satisfactory CUE: STA will enter the time and date for exiting Tech Spec.
THIS JPM IS COMPLETE.
Page 11 of 11
CONTROL ROOM JPM e Facility: DC Cook Task No: ______
Task
Title:
PRESSURIZER HEATER CAPACITY TEST Job Performance Measure No: _CR JPM e K/A
Reference:
____010 A4.02 ____
Examinee: NRC Examiner: _________________
Facility Evaluator: Date: _________________________
Method of testing:
Simulated Performance _______________ Actual Performance _____X___________
Classroom ______________ Simulator _____X________ Plant __________
Task Standard: Pressurizer heater capacity test is completed.
Required Materials: 2-OHP-4030-202-040, Rev. 000, PRESSURIZER HEATER CAPACITY TEST General
References:
2-OHP-4030-202-040 Read to the examinee:
Initial Conditions: Plant is at 100% with all equipment functioning normally Initiating Cue: You are the extra RO on shift. The Unit Supervisor directs you to perform a pressurizer heater capacity test in service in accordance with 2-OHP-4030-202-040, Rev. 000, Pressurizer Heater Capacity Test.
Time Critical Task: No Validation Time: 15 minutes Page 1 of 6
EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
CUE: ALL Prerequisites are Met Standard: Direct AEO to Check 21PHA-4 Welding Receptacles Breaker - OPEN SAT: UNSAT:
COMMENT:
CUE: 21PHA-4 Welding Receptacles Breaker isOPEN Page 2 of 6
EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Verifiy Open Breakers:
- 21PHA6 - SCR
- 21PHA2
- 21PHA3
- 21PHA5 SAT: UNSAT:
COMMENT:
Standard: Verify T21A6 is CLOSED SAT: UNSAT:
COMMENT:
Standard: Verify 0 AMPS SAT: UNSAT:
COMMENT:
Standard: Close the Breakers:
- 21PHA2
- 21PHA3
- 21PHA5 CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Record AMP Reading SAT: UNSAT:
COMMENT:
Standard: Return Controls to Normal:
CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Verify Difference > 25 Amps SAT: UNSAT:
COMMENT:
Page 3 of 6
EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
CUE: 21PHA-4 Welding Receptacles Breaker isOPEN as required Standard: Verifiy Open Breakers:
- 21PHC6 - SCR
- 21PHC2
- 21PHC3
- 21PHC5 SAT: UNSAT:
COMMENT:
Standard: Verify T21D9 is CLOSED SAT: UNSAT:
COMMENT:
Standard: Verify 0 AMPS SAT: UNSAT:
COMMENT:
Standard: Close the Breakers:
- 21PHA2
- 21PHA3
- 21PHA5 CRITICAL STEP SAT: UNSAT:
COMMENT:
Standard: Record AMP Reading SAT: UNSAT:
COMMENT:
Standard: Return Controls to Normal:
CRITICAL STEP Page 4 of 6
EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Standard: Verify Difference > 25 Amps SAT: UNSAT:
COMMENT:
Terminating Cue: The JPM is Complete.
Page 5 of 6
EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Page 6 of 6
CONTROL ROOM JPM f Facility: DC Cook Task No: ______
Task
Title:
CONTAINMENT PRESSURE RELIEF (ALTERNATE PATH)
Job Performance Measure No: _ CR JPM f K/A
Reference:
_029 A1.03 3.0/3.3_
Examinee: NRC Examiner: _________________
Facility Evaluator: Date: _________________________
Method of testing:
Simulated Performance _______________ Actual Performance _____X___________
Classroom ______________ Simulator _____X________ Plant __________
Task Standard: CONTAINMENT PRESSURE IS REDUCED.
Required Materials: 2-OHP.4021.028.004 Operation of the Containment Pressure Relief System General
References:
2-OHP.4021.028.004 Operation of the Containment Pressure Relief System Read to the examinee:
Initial Conditions: Unit 2 is operating at 100% power. Containment pressure has risen due to previous problems associated with containment cooling. Pressure is
+0.18 psig and the Unit Supervisor directed that containment pressure be reduced in accordance with 2-OHP 4021-028-004, Operation of the Containment Pressure Relief System There are no abnormal RCS leak rates. All radiation monitors are operable. Containment pressure relief system absolute and charcoal filters are operable.
Initiating cue: The Unit Supervisor has directed you to relieve containment pressure to less than 0.00 psig in accordance with 2-OHP 4021-028-004, Operation of the Containment Pressure Relief System Time Critical Task: No Validation Time: 15 Minutes Page 1 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
CUE: Containment pressure relief system absolute and charcoal filters are operable.
Standard: Candidate Reviews Precautions & Limitations SAT: UNSAT:
COMMENT:
CUE: All radiation monitors are operable Page 2 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Page 3 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
Information in this note is typically reviewed and discussed in task briefing.
NOTE: Not part of JPM.
CUE: None of the planned evolution activities are scheduled during the time we will be performing the pressure relief.
{NOTE: JPM starts here.}
STANDARD: Operator verifies that all listed monitors are functioning properly SAT: UNSAT:
CUE: If asked, AEO reports that 2-VFS-2521 is operating within the Normal range.
STANDARD: Operator determines that ALL channels are OPERABLE SAT: UNSAT:
Page 4 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
N/A N/A NOTE: This is typically reviewed and discussed as part of the task briefing.
CUE: Shift Manager deems NONE of these actions as necessary.
Page 5 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
NOTE: Data is recorded on Section A of Data Sheet 1 (FYI Page 13 of JPM)
STANDARD: Enter Next CPR number CUE: Next Containment Pressure Relief Number is 14-0058 SAT: UNSAT:
STANDARD: Record Vent Flow from 2-VFR-2510 or 2-VFR-315 on recorder 2-MR-54 and circles source Critical step SAT: UNSAT:
STANDARD: Record Containment Pressure Critical step SAT: UNSAT:
STANDARD: Record Radiation Monitor readings Critical step SAT: UNSAT:
STANDARD: Perform Source Check on 2-ERS-2305 Critical step SAT: UNSAT:
STANDARD: Perform Source Check on 2-ERS-2405 Critical step SAT: UNSAT:
STANDARD: Verify all Trip block switches in NORMAL SAT: UNSAT:
Page 6 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
STANDARD: Initial Data Sheet 1 SAT: UNSAT:
N/A CUE: If Required, Audible alarm is Available N/A NOTE: These contingencies may be reviewed by the Operator.
They will be used later in this JPM and are repeated when appropriate.
Page 7 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
CUE: If asked, 2-VFC-207 Containment Pressure Relief Flow controller is set at 500 cfm.
STANDARD: CS Places 2-VCR-107 to OPEN.
Critical step SAT: UNSAT:
STANDARD: CS Places 2-VCR-207 to OPEN and holds.
Critical step SAT: UNSAT:
CUE: After VCR-107 and VCR-207 are open, US directs you to start HV-CPR-1, CNTMT Pressure Relief Vent Unit.
STANDARD: CS 2-HV-CPR-1 Fan switch is placed in START.
{NOTE: Rad Alarm on VRS-2501 in ~30 secs)
Critical step SAT: UNSAT:
N/A STANDARD: Operator records start time in Section B SAT: UNSAT:
Page 8 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
PAGE REPEATED (ALTERNATE PATH BEGINS HERE)
STANDARD: Operator reports HI Alarm on VRA-2501 SAT: UNSAT:
STANDARD: Operator places 2-HV-CPR-1 fan to STOP Critical step SAT: UNSAT:
STANDARD: Operator places 2-VCR-107 to CLOSE SAT: UNSAT:
STANDARD: Operator places 2-VCR-207 to CLOSE Critical step SAT: UNSAT:
STANDARD: Operator records unit vent flow rate SAT: UNSAT:
STANDARD: Operator request RP recalculate High alarm setpoint SAT: UNSAT:
EVALUATOR: JPM is COMPLETE Page 9 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
NOTE: Included for information only.
Page 10 of 11
CONTROL ROOM JPM f EXPECTED ACTIONS CUES/STANDARDS (Critical Steps in bold)
NOTE: Included for information only.
Page 11 of 11
CONTROL ROOM JPM g Facility: DC Cook Task No: ______
Task
Title:
Respond to High Control Room Radiation (ALTERNATE PATH)
Job Performance Measure No: _CR JPM g_ K/A
Reference:
____ P2.3.13__
Examinee: NRC Examiner: _____________________
Facility Evaluator: Date: _____________________________
Method of testing:
Simulated Performance _______________ Actual Performance
______X____________
Classroom ______________ Simulator _____X________ Plant __________
Task Standard: Control Room ventilation has been isolated.
Required Materials: None-Use Simulator Control Room procedures General
References:
02-OHP-4021-028-014, OPERATION OF THE CONTROL ROOM AIR CONDITIONING AND PRESSURIZATION/CLEANUP FILTER SYSTEMS, Rev 37 12-OHP-4024-139, ANNUNCIATOR #139 RESPONSE EBERLINE RADIATION, Rev. 16 Read to the examinee:
Initial Conditions: Unit 1 has experienced an accident which has resulted in several unexpected radiation monitor alarms within the Auxiliary Building. ERS-8401, Unit 2 Control Room Area Monitor High alarm (Red) has just been received.
Initiating Cue: You have been directed to respond to the ERS-8401 Red alarm using the alarm response procedure. Report when all actions have been completed.
This is a Time Critical JPM (20 minutes)
Validation Time: 10 MINUTES Page 1 of 7
CONTROL ROOM JPM g EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
NOTE: The Operator may manipulate equipment based on failure of an auto action to occur. This will satisfy the critical steps as long as the equipment is properly aligned at the end of the JPM STANDARD: Operator reviews automatic actions and determined they did not occur SAT: UNSAT:
COMMENT:
(NOTE : ONLY ONE pressurization fan should be left running MAY be Stopped at Step 4.4 in 2OHP-4021-028-014)
Page 2 of 7
CONTROL ROOM JPM g EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator determines the alarm is unexpected and sounds the Containment Evacuation alarm using the switch located on the Flux/Rod Control Panel.
Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator determines automatic actions did not occur and that Control Room ventilation must be manually aligned.
SAT: UNSAT:
COMMENT:
(NOTE : ONLY ONE pressurization fan should be left running MAY be Stopped at Step 4.4 in 2OHP-4021-028-014)
Page 3 of 7
CONTROL ROOM JPM g EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
NOTE:
No actions required, included for Evaluator reference Page 4 of 7
CONTROL ROOM JPM g EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
STANDARD: Operator closes both outside air dampers Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator partially opens ONE Control Room Pressurization/Cleanup Intake Damper Critical Step SAT: UNSAT:
COMMENT:
STANDARD: Operator starts ONE Control Room pressurization fan Critical Step SAT: UNSAT:
COMMENT:
(NOTE : ONLY ONE pressurization fan should be left running)
STANDARD: Operator determines that OHI-4016 Data Sheet 1 should be completed CUE: Another operator will be responsible to complete Data Sheet 1 SAT: UNSAT:
COMMENT:
STANDARD: STOPS ONE Control Room pressurization fan if both were running/started Critical Step - ONLY ONE pressurization fan is left running SAT: UNSAT:
COMMENT:
Page 5 of 7
CONTROL ROOM JPM g EXPECTED ACTIONS CUES/STANDARDS (Critical Step in bold)
NOTE: The following step is not critical since ERS-7401 operated as designed STANDARD: Operator notifies Unit 1 to manually place the Unit 1 Control Room ventilation system in the pressurization mode CUE: Acknowledge the direction and report that automatic actions associated with ERS-7401 occurred and properly aligned the ventilation systems SAT: UNSAT:
COMMENT:
STANDARD: Operator notifies RP of the alarm and requests verification of 12-THP-6010-RPP-708 CUE: RP acknowledges communication SAT: UNSAT:
COMMENT:
Termination Cue: When operator reports completion of alarm response actions.
Page 6 of 7
CONTROL ROOM JPM g Page 7 of 7
CONTROL ROOM JPM h Facility: DC Cook Task No: ______
Task
Title:
Perform Emergency Boration due to Shutdown Margin Not Met (ALTERNATE PATH)
Job Performance Measure No: CR JPM h K/A
Reference:
___024 A1.17___
Examinee: NRC Examiner: _________________
Facility Evaluator: Date: _________________________
Method of testing:
Simulated Performance _______________ Actual Performance ______X_______
Classroom ______________ Simulator _____X________ Plant __________
Task Standard: Operator has established Emergency Boration to the RCS.
Required Materials: 01-OHP-4021.-005-007, Operation of Emergency Boration Flow Paths General
References:
01-OHP-4021-005-007, R4, Operation of Emergency Boration Flow Paths Read to the examinee:
Task Briefing: You are the Reactor Operator. The crew has just performed 1-OHP-4021-001-012, Determination of Reactor Shutdown Margin and discovered that Shutdown Margin has NOT been met.
The Unit Supervisor directs you to initiate Emergency Boration to the RCS in accordance with 1-OHP-4021-005-007, Operation Of Emergency Boration Flow Paths, using the Preferred Method.
Time Critical Task: No Validation Time: 20 Minutes Page 1 of 5
CONTROL ROOM JPM h EXPECTED ACTIONS CUES/STANDARDS (CS Indicates Critical Standard)
STANDARD: Operator Places Speed Selector for operating Boric Acid Transfer pump in FAST. (May place both Speed Selectors in FAST)
SAT: UNSAT:
STANDARD: Operator Verifies BA Transfer Pump Recirculation valves are closed.
SAT: UNSAT:
STANDARD: Operator verifies 1-QRV-411 and 1-QRV-412 are closed.
SAT: UNSAT:
STANDARD: (CS) Operator attempts to open 1-QMO-410.
SAT: UNSAT:
STANDARD: Operator identifies failed 1-QMO-410, and no flow on 1-QFI-410 SAT: UNSAT:
CUE: If asked, as Unit Supervisor direct the candidate to complete the boration using another method.
CONTROL ROOM JPM h EXPECTED ACTIONS CUES/STANDARDS (CS Indicates Critical Standard)
Note: Step 4.1.2 is N/A (The IMO-910 and IMO-911 valves will fail to open if the operator attempts to use this flowpath.)
CUE: Blender is NOT aligned to CVCS HUT or RWST.
STANDARD: (CS) Operator Verifies Speed Selector for operating Boric Acid Transfer pump in FAST. (Previously placed in FAST Speed)
SAT: UNSAT:
STANDARD: Operator verifies following closed:
12-QRV-420, Middle BAT Recirc l-QRV-410, North BA Tank Recirc 1-QRV-451, Blender To VCT 1-QRV-412, Prim Water to Blender SAT: UNSAT:
CONTROL ROOM JPM h EXPECTED ACTIONS CUES/STANDARDS (CS Indicates Critical Standard)
STANDARD: (CS) Operator Opens 1-QRV-400 and 1-QRV-411.
SAT: UNSAT:
STANDARD: (CS) Operator Verifies Flow at 1-QFC-411 Is Greater Than 36 gpm.
SAT: UNSAT:
STANDARD: Operator verifies at least ONE Charging Pump running.
SAT: UNSAT:
STANDARD: Operator verifies open the following 1-QMO-200 and l-QMO-201.
SAT: UNSAT:
STANDARD: Operator verifies open OR throttled 1-QRV-251 and 1-QRV-200 SAT: UNSAT:
STANDARD: Operator verifies open EITHER 1-QRV-61 OR 1-QRV-62.
SAT: UNSAT:
CUE: QRV-200 is NOT failed closed Note: Step 4.2.3 is N/A
CONTROL ROOM JPM h EXPECTED ACTIONS CUES/STANDARDS (CS Indicates Critical Standard)
Note: Step 4.2.4 is N/A STANDARD:Operator Verifies Flow at 1-QFI-200 Is Greater Than 50 gpm..
SAT: UNSAT:
Note: Step 4.2.6 is N/A STANDARD: Operator Diverts Letdown as required to maintain VCT level and pressure.
SAT: UNSAT:
TERMINATION CUE: This JPM is complete.