March 9, 1990W Docket No.

50-261 Mr.

Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

PRESSURE-TEMPERATURE LIMITS RELATING TO GENERIC LETTER 88-11 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO. 71542)

By letter dated December 22, 1988, you responded to Generic Letter 88-11 which requires the licensee to use Regulatory Guide 1.99, Revision 2, to calculate the nil-ductility reference temperature of reactor vessel beltline materials. The reference temperature relates to pressure-temperature limits in Technical Specifications. In the letter, you requested approval of calculation of reference temperature using data from surveillance capsules T and V before submitting revised pressure-temperature limits.

We have completed the review of the request. Based on our evaluation, we approve the calculation of reference temperature using the surveillance capsule data. We expect you to proceed with the generation of revised heatup and cooldown curves and low-temperature overpressure protection setpoints based on the surveillance capsule data.

Sincerely, Orignal signed by:

Ronnie H. Lo, Senior Project Manager Project Directorate II-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION See attached page OFC :LA:P y :PM:PDII-1

D:PDII NAME :PA
RLo: Sw/4 :EAdensa DATE:
3/

/90 3/ 90 OFFICIAL RECORD COPY Document Name:

LTR EURY 71542 PD ADu'CK 050W26 1 P

Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. R. E. Jones, General Counsel Mr.

Dayne H. Brown, Director Carolina Power & Light Company Department of Environmental, P. 0. Box 1551 Health and Natural Resources Raleigh, North Carolina 27602 Division of Radiation Protection P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff -

NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Manager, Robinson Nuclear Project H. B. Robinson Steam Electric Plant Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsville, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr.

Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. R. Morgan

Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550

DISTRIBUTION Docket File NRC PDR Local PDR S. Varga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B-20 R. Lo 14-B-20 OGC (For inform. Only) 15-8-18 E. Jordan MNBB-3302 ACRS (10)

P-315 ROBINSON FILE