January 12, 1990 Docket No. 50-261 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company P.O. Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

REVIEW OF 60-DAY RESPONSE TO GENERIC LETTER 88-20, INDIVIDUAL PLANT EXAMINATIONS (IPE) - H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO. 74460)

Generic Letter 88-20 requires, in part, that each operating reactor licensee and construction permit holder: (1) identify the approach and method selected for performing the IPE, (2) describe the method to be used, and (3) identify the schedule for performing the IPE and submitting the results to the NRC.

This information was to be submitted to the NRC within 60 days of issuance of Supplement 1 of the generic letter.

We have reviewed your letter dated October 31, 1989 submitted in response to the reporting requirements of the generic letter. We conclude that your IPE approach, methodology and schedule are acceptable. We anticipate that any possible additional analysis or reporting requirements, such as those from external events or from the Containment Performance Improvement Program, will not have any adverse effect on your schedule. However, if your schedule should change, please notify the NRC of the proposed change and the reason for the change.

Should you have any questions concerning the requirements of the generic letter, please contact Mr. Michael L. Boyle, NRR at (301) 492-1308 or Mr. John H. Flack, RES at (301) 492-3979.

Sincerely, Original Signed By:

Ronnie Lo, Senior Project Manager Project Directorate II-1 Division of Reactors Projects I/II Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION 9001220078 900112 See attach page PDR ADOCK 05000261 F

PDC OFC

PDI

.PDII-1

PDII-1 NAME :PAn e
RLo:sw
ETourign V:

DATE :1/f/&90

1/P/90
1/,L/90 OFFICIAL RECORD COPY Document Name: ROB IPE LTR

Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. R. E. Jones, General Counsel Mr. Dayne H. Brown, Chief Carolina Power & Light Company Radiation Protection Branch P. 0. Box 1551 Division of Facility Services Raleigh, North Carolina 27602 Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff -

NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Manager, Robinson Nuclear Project H. B. Robinson Steam Electric Plant Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsville, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. R. Morgan Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550

DISTRIBUTION Docket File NRC PDR Local PDR S. Varga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B-20 R. Lo 14-B-20 OGC (For inform. Only) 15-B-18 E. Jordan MNBB-3302 M. Boyle 13-H-3 J. Flack NLS324 ACRS (10)

P-315 Robinson File