JAN 0 7 1988 Docket No. 50-261 DISTRIBUTION Docket File ACRS (10)
Mr. E. E. Utley NRC & Local PDRs Senior Executive Vice President PD 21 r/f Power Supply and Engineering & Construction S. Varga Carolina Power & Light Company G. Lainas Post Office Box 1551 P. Anderson Raleigh, North Carolina 27602 K. Eccleston OGC-B
Dear Mr. Utley:
E. Jordan J. Partlow
SUBJECT:
EXTENDED BURNUP TOPICAL REPORT XN-NF-87-17 (TAC NO. 55156)
By letter dated March 20, 1987, Carolina Power & Light Company (CP&L) submitted a topical report entitled "Mechanical Design Report for H. B. Robinson Extended Burnup Assemblies" (XN-NF-87-17). This report described fuel assembly design for extended burnup based on the approved generic topical report XN-NF-82-06, Rev. 1 (Qualification of ANF Fuel for Estimated Burnup Report).
We have completed our review of your submittal for extended fuel burnup for H. B. Robinson, Unit No. 2, and conclude that topical report XN-NF-87-17 is acceptable for extended burnup licensing applications at the H. B. Robinson facility.
The enclosed Safety Evaluation Report documents our findings.
Sincerely, Kenneth T. Eccleston, Sr. Project Manager Project Directorate II-1 Division of Reactor Projects I/II
Enclosure:
As stated cc w/enclosure:
See next page LA:
PM:P4 RPR 0
DRP PAnd r KEccleston/dsf EAdensam 1/ /88 1/-j /88 1/7/88 6801140044 880107 PDR ADOCK 05000261 P
Mr. E. E. Utley Carolina Power & Light Company H. B. Robinson 2 cc:
Mr. R. E. Jones, General Counsel Mr. Dayne H. Brown, Chief Carolina Power & Light Company Radiation Protection Branch P. 0. Box 1551 Division of Facility Services Raleigh, North Carolina 27602 Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008 Mr. McCuen Morrell, Chairman Darlington County Board of Supervisors Mr. Robert P. Gruber County Courthouse Executive Director Darlington, South Carolina 29535 Public Staff - NCUC P.O. Box 29520 Mr. H. A. Cole Raleigh, North Carolina 27626-0520 Special Deputy Attorney General State of North Carolina P.O. Box 629 Raleigh, North Carolina 27602 Mr. D. E. Hollar Associate General Counsel Carolina Power and Light Company P.O. Box 1551 Raleigh, North Carolina 27602 U.S. Nuclear Regulatory Commission Resident Inspector's Office H. B. Robinson Steam Electric Plant Route 5, Box 413 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Suite 2900 101 Marietta Street Atlanta, Georgia 30303 Mr. R. Morgan General Manager H. B. Robinson Steam Electric Plant Post Office Box 790 Hartsville, South Carolina 29550 Mr. Avery Upchurch, Chairman Triangle J Council of Governments 100 Park Drive Post Office Box 12276 Research Triangle Park, NC 27709