Docket No. 50-261

License No. DPR-23

Carolina Power and Light Company

ATTN:

Mr. Lynn W. Eury

Executive Vice President

Power Supply

P. 0. Box 1551

Raleigh, NC 27602

Gentlemen:

SUBJECT:

NOTICE OF VIOLATION

(NRC INSPECTION REPORT NO. 50-261/90-13)

This refers to the Nuclear Regulatory Commission (NRC)

inspection conducted by

W. M. Sartor on June 17-21,

1990.

The inspection included a review of

activities authorized for your H. B. Robinson facility. At the conclusion of

the inspection, the findings were discussed with those members of your staff

identified in the enclosed Inspection Report.

Areas examined during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel,

and observation of

activities in progress.

The inspection findings indicate that certain activities appeared to violate

NRC requirements.

The violation, references to pertinent requirements,

and

elements to be included in your response are described in the enclosed Notice

of Violation.

Your attention is directed to the commitment for prompt corrective action,

a drill to demonstrate the effectiveness of the corrective action, and

management meeting referenced in Paragraph 11.

Since that commitment, further

discussions have delayed the management meeting to a later date.

If your

understanding of the commitment differs from that presented, please let us know

immediately.

The responses directed by this letter and its enclosures are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, Pub. L. No.96-511.

2 C)

900727

ADR

OC 0:00

'26

F; * C

Carolina Power and Light Company

2

Should you have any questions concerning this letter, please contact us.

Sincerely,

ORiGINAL SIGW) 5Y

DOUGLAS M. COtUE

J. Philip Stohr, Director

Division of Radiation Safety

and Safeguards

Enclosures:

1. Notice of Violation

2. NRC Inspection Report

cc w/encls:

C. R. Dietz, Manager

Robinson Nuclear Project Department

H. B. Robinson Steam Electric Plant

P. 0. Box 790

Hartsville, SC 29550

R. E.

Morgan, Plant General Manager

H. B. Robinson Steam Electric Plant

P. 0. Box 790

Hartsville, SC 29550

Heyward G. Shealy, Chief

Bureau of Radiological Health

Dept. of Health and Environmental

Control

2600 Bull Street

Columbia, SC 29201

Dayne H. Brown, Director

Division of Radiation Protection

N. C. Department of Environment,

Health & Natural Resources

P. 0. Box 27687

Raleigh, NC 27611-7687

McCuen Morrell, Chairman

Darlington County Board of Supervisors

County Courthouse

Darlington, SC 29535

(cc w/encls: Cont'd on page 3)

Carolina Power and Light Company

3

(cc w/encls:

cont'd)

Richard E. Jones, General Counsel

Carolina Power and Light Company

P. 0. Box 1551

Raleigh, NC 27602

H. A. Cole

Special Deputy Attorney General

State of North Carolina

P. 0. Box 629

Raleigh, NC 27602

Robert Gruber

Executive Director

Public Staff -

NCUC

P. 0. Box 29520

Raleigh, NC 27626-0520

bcc w/encls:

Document Control Desk

R. A. Erickson, NRR/PEPB

J. Heard, FEMA, RGN IV

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

Route 5, Box 413

Hartsville, SC 29550.

R4

SS

S

RII:DRSS

RII DRP

O

WSartor

WRankin

DCollins

\\ (IDa ce

7/,4/90

7//0/90

7/ /90

7/4\\/90