APPENDIX A NOTICE OF VIOLATION Carolina Power and Light Company Docket No. 50-261 H. B. Robinson 2 License No. DPR-23 As a result of the inspection conducted on June 11 - July 10, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980),

the following violation was identified.

10 CFR 50.59 allows the licensee to make changes to the facility and procedures as described in the safety analysis report, without prior Commission approval, unless the change constitutes an unreviewed safety question. A proposed changeis deemed to involve an unreviewed safety question if a possibility for an accident or malfunction of a different type than any evaluated previously in the safety analysis report may be created.

Additionally the licensee shall maintain records of such changes to the facility and procedures, including a written safety evaluation which provides the bases for the determination that the change 'does not involve an unreviewed safety question, and shall furnish at least annually a report containing a brief description of such changes including a summary of the safety evaluation of each.

Contrary to the above, these requirements were not met in that:

(1) Modification 383, which installed increased-capacity waste condensate tanks located outside the auxiliary building with unmonitored, unvalved vents to atmosphere, was not adequately reviewed to reach the conclusion that it did not constitute an unreviewed safety question.

(2) Modification 383, a change to the facility as described in the FSAR and implemented in 1978, has not been reported to the Commission.

(3) The licensee did not adequately review the safety implications of the transfer of untreated waste water to E Waste Condensate Tank on November 27, 1980 and its subsequent storage there.

This is a Severity Level IV Violation (Supplement I.D.1.).

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, including: (1) admission or denial of the alleged viola tion; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be given to extending your response time for good PiU AsxKi 050CW 11.t

Carolina Power & Light Company 2

Docket No. 50-261 Notice of Violation License No. DPR-23 cause shown. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

Date: JUL22 1881