Text
APPENDIX A NOTICE OF VIOLATION Carolina Power and Light Company License No. DPR-2 H. B. Robinson 2 Based on the NRC inspection on January 22-25, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below. These items have been categorized as described in correspon dence to you dated December 31, 1974.
A.
As required by 10 CFR 50.59(b),
a written safety evaluation must be maintained which provides the basis for the determination that a change in the facility as described in the safety analysis report does not involve an unreviewed safety question.
Contrary to the above, the safety evaluation for PJ-3.0, Containment Spray Nozzle Five Year Test, did not provide a written basis that the permanent removal of two blind flanges on the spray system piping did not involve an unreviewed safety question.
The blind flanges are described in the Final Safety Analysis Report by figures 5.2.2-6 and 6.2-1, and had been permanently removedduring the performance of PT-30 in November, 1975.
This is an infraction.
Z9 04 1000 30