GNRO-2014/00024, Response to Request for Additional Information Regarding Maximum Extended Load Line Limit Plus Amendment Request, Dated 2/6/2014

From kanterella
(Redirected from ML14069A103)
Jump to navigation Jump to search

Response to Request for Additional Information Regarding Maximum Extended Load Line Limit Plus Amendment Request, Dated 2/6/2014
ML14069A103
Person / Time
Site: Grand Gulf 
Issue date: 03/10/2014
From: Kevin Mulligan
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GNRO-2014/00024, TAC MF2798
Download: ML14069A103 (18)


Text

~Entergy contains PROPRIETARY information GNRO-2014/00024 March 10, 2014 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Entergy Operations, Inc.

P. O. Box 756 Port Gibson, MS 39150 Kevin MUlligan Site Vice President Grand Gulf Nuclear Station Tel. (601) 437-7400

SUBJECT:

Response to Request for Additional Information Regarding Maximum Extended Load Line Limit Plus Amendment Request, dated 2/6/2014.

Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 Licen$e No. NPF-29

REFERENCES:

1 Electronic Request for Additional Information Regarding Maximum Extended Load Line Limit Plus Amendment Request Dated 2/6/2014 (TAC MF2798) 2 Entergy Letter, "Maximum Extended Load Line Limit Analysis Plus (MELLLA+) License Amendment Request," GNRO-2013/00012, dated September 25,2013 (ADAMS Accession No. ML13269A140).

Dear Sir or Madam:

Entergy Operations, Inc. is providing in the Enclosures a response to the Reference 1 Request for Additional Information (RAI). contains proprietary information as defined by 10 CFR 2.390. General Electric-Hitachi (GEH), as the owner of the proprietary information, has executed the enclosed affidavit, which identifies that the enclosed proprietary information has been handled and classified as proprietary, is customarily held in confidence,' and has been withheld from public disclo.sure. The proprietary information was provided to Entergy in a GEH transmittal that is referenced by the affidavit. The proprietary information has been faithfully reproduced in the enclosed such that the affidavit remains applicable. GEH hereby requests that the enclosed proprietary information be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390 and 9.17.

Information that is not considered proprietary is provided in Enclosure 2. Enclosure 3 contains an affidavit which identifies that the information contained in Enclosure 1 has been handled and classified as proprietary to GEH. On behalf of GEH, Entergy requests that Enclosure 1 be withheld from public disclosure in accordance with 10 CFR 2.390(b)(1).

When Enclosure 1 is removed from this letter, the entire document is NON-PROPRIETARY

GNRO-2014/00024 Page 2 of 2 This letter contains no new commitments. If you have any questions or require additional information, please contact Mr. Jeffery Seiter at 601-437-2344 Sincerely,

)60L

--_ ------"L_----_

KJM~as

~

Enclosures:

1 Proprietary Responses to the Request for Additional Information 2 Non-Proprietary Responses to the Request for Additional Information 3 GEH Affidavit for Enclosure 1 cc: with Enclosures U.S. Nuclear Regulatory Commission ATTN: Mr. Marc L. Dapas Regional Administrator, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 U.S. Nuclear Regulatory Commission ATTN: Mr. A. Wang, NRR/DORL Mail Stop OWFN/8 G14 11555 Rockville Pike Rockville, MD 20852-2378 NRC Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150 State Health Officer Mississippi Department of Health P. O. Box 1700 Jackson, MS 39215-1700 to GNRO-2014/00024 Non-Proprietary Responses to the Request for Additional Information

GEH-GGNS-AEP-636 Responses to Requests for Additional Information in Support of GGNS MELLLA+LAR Non-Proprietary Information - Class I (Public)

NON-PROPRIETARY NOTICE This is a non-proprietary version of Enclosure 1 of GEH-GGNS-AEP-636 which has the proprietary information removed.

Portions of the document that have been removed are indicated by an open and closed bracket as shown here ((

)).

Non-Proprietary Infonnation - Class I (Public)

GEH-GGNS-AEP-636 RAJ 1 Page 1 of 10 Section 9.3.3 of Attachment 4 states that zirconium credit will be used in the Shumway correlation. The NRC staffhas reviewed the zirconium data described in letter dated September 9, 2013 (ADAMS Accession No. ML13253A105), from GE Hitachi Nuclear Energy and has the following questions a.

Fresh fuel that has little or no oxide at the start ofthe transient and thefresh fuel is often in the more reactive part ofthe core; therefore, it is the data ofinterest. Figure 6 ofthe September 9, 2013, letter has many data sets provided together on it.

Provide a plot showing clean zirconium separate from all the other data including SS, Inconel, zirconium oxide and any data that would be expected to have oxidizedzirconium.

b.

In the September 9, 2013 letter, much ofthe Hoffman (FKZ) data that has a rapid cooling rate early in the experiment that may have been incorrectly interpreted as quench.

A closer examination ofthe data shows this initial cooling was due to startup ofthe test and that quench occurred much later at significantly lower temperatures.

In addition, because ofhigh temperatures during the tests and pre-conditioning ofthe rods, the rods are likely have thick oxide layer thicknesses that are not representative offuel in a commercial reactor undergoing an Anticipated Transient without Scram with Instability (ATWS-I) event.

Provide a plot sho~ing the data considered valid by the licensee for justifying Shumway as implemented in TRACG for the intended application (e.g. ATWS-I under MELLLA +).

Textual justification to support the choice of the selected data and exclusion ofthe other data should be providedfocusing on comparing the applicable test conditions to the plant application conditions to support a conclusion that the data is applicable.

GEH Response to Parts (a) and (b)

Other materials were included in the original Figure 6 of Reference 1-1 to illustrate that the Shumway correlation matches very nicely the trend in both the data and the correlation from Henry over a wide range of material thennal properties and water pressures. Data for zirconium (Zr) with or without oxide is limited for the reasons cited in Reference 1-1 so consideration of collaborative evidence using other materials is essential and commonly practiced in designing experiments. Another key point being made in Reference 1-1 is that the presence of zirconium dioxide (Zr02) increases the value for Tmin and this credit is conservatively not utilized by the Shumway correlation.

As requested in Part (a) of the RAI, data for stainless steel (SS) and Inconel have been removed from the original Figure 6 of Reference 1-1 together with the correlation curves pertaining to these materials and zirconium dioxide. The revised plot is provided in Figure 1-1. The solid red curve in Figure 1-1 is for the Shumway correlation using unoxidized zircaloy properties and no credit for the void tenn. The correlation as implemented in TRACG compares very well to the data shown by solid red circles that was characterized by Peterson and Bajorek (Reference 1-3) for clean zirca10y samples. There were no data points on the, original figure that were specific to Zr02 although many of Hofmann's data points (Reference 1-2) were from zircaloy cladding that had some oxide layer on the surface as indicated by the figure legends. Fresh fuel does have less oxide at the start of the transient than fuel that has been exposed; however, the assertion that Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 2 of 10 fresh boiling water reactor (BWR) fuel is "often in the more reactive part of the core; therefore, it is the data of interest" is not accurate. The hot rods in the hot fuel bundles in the core are of interest. The location in the core is not important. It is the highest power fuel bundles that are important.

It is the highest reactivity fuel bundles that generally results in the highest power.

Because of the presence of gadolinium, the peak reactivity for a typical BWR fuel bundle occurs at an exposure between 10 and 20 GWdlMTU which occurs roughly for fuel towards the end of its first cycle.

Oxide accumulates slowly as a function of exposure during normal BWR operations.

The exposure argument is not relevant because the amount of pre-transient oxide remains low because the normal BWR clad operating temperature is low and there is very limited oxygen available to form an oxide. Based on measured oxide data, the maximum pre-transient oxide is less than ((

)) even for exposures as high as ((

)).

Initial oxide amounts for the Hofmann (FKZ) tests were carefully created using controlled pre-transient conditioning at high temperatures with cooling supplied mainly by argon to limit the oxygen available for oxidation.

Nominal pre-transient oxide layers from 0 to 350 Jlm were studied and the amount of oxide predicted by calculations was confirmed by measurements. For the pre-oxidized specimens, steam was mixed with the argon to provide an oxygen source and the time and temperature were controlled to achieve the desired amount of oxidation.

Any additional oxide formation during the transient tests has been estimated for each test by integrating the Cathcart reaction rate equation from the beginning of the transient to the quench time using an average of the reaction rates at the initial and final conditions.

The oxide production rate increases exponentially with temperature but also decreases inversely proportional to the accumulated oxide thickness. The time at the high temperature where oxygen from water is also available to form oxide was relatively short so the incremental amounts of oxide formed during the Hofmann transients are relatively small once some oxide has formed.

The original Figure 6 from Reference 1-1 was constructed by reviewing more than 85 data traces from Hofmann and rejecting all but those where the quench was obvious. The original usable set included seven for zero oxide, 16 for 100 Jlm oxide and 24 at 300 Jlm oxide.

Part (b) of the RAI asserts that "initial cooling was due to startup of the test and that quench occurred much later at significantly lower temperatures."

It is true that early temperature decreases recorded for the thermo-couples at the upper and middle elevations can easily be misinterpreted as a quench when in fact the rapid temperature reduction may be due to a sudden*

increase in steam cooling as quenching occurred at a lower elevation.

All data traces were critically reviewed again with attention on whether the temperature reduction rate was maintained at a high or increasing value after the time the quench temperature was recorded.

Also the time of the quench has been recorded.

Quench times less than 5.0 seconds are not expected for the thermo-couples at the center and upper elevations. Temperature traces that did not meet this additional scrutiny were rejected.

Most notably, six of the seven original temperature traces with zero oxide were eliminated so that only one trace remained (and it is questionable as suggested by the red highlighting in Table 1-1). The more objective criteria were also applied to the traces that had 100 Jlm and 300 Jlm pre-transient oxides which resulted in the removal of a few traces and the addition of a few others. The revised statistics are presented in Table 1-1.

In view of the standard deviations, there is no statistically significant difference in the quench temperatures as the initial oxide increases from 100 to 300 Jlm. The key-points are that the Hofmann data supports the material property dependence in the Shumway correlation Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 3 of 10 and assuming clean zircaloy in the application of the correlation results in a Tmin value that is conservatively below the data.

Table 1-1 Oxide (flm) 0 100 16 469 839 554 574 97 300-24 389 809 539 562 124 All 40 389 839 539 567 113 Details for forty-two (42) temperature traces from Hofmann are presented in Table 1-2 to facilitate independent critical review of how the data traces in Reference 1-2 were processed.

The two data points shaded in red in Table 1-2 are unbelievably high and significantly different from all the other values in the table. These values are from two thermo-couples (TICs) at the lowest elevation so an early quench time is expected. The temperature traces from which these points were obtained appear to indicate a liquid quench; however, it is also possible that the traces are indicating that these TICs detached from the rod or failed in some other way. These two red data points are not shown in Figure 1-1 and they are not considered in the statistics in Table 1-1.

Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 4 of 10 Table 1-2 Details for Hofmann TQ Values Quench Initial Transient Page Figure(s)

Elevation Curve Time Oxide Oxide s

106 3.15 3.16 lower LI007 1 800 5.1 689 100 1.9 107 3.17 3.18 center CI007 1 720 9.0 609 100 3.4 108 3.19 3.20 u

er UI007 1 680 17.1 569 100 6.3 108 3.19 3.20 u

er U31056 1 600 14.0 489 100 5.2 115 3.33 3.34 lower L0507 1 950 1.8 839 100 0.2 115 3.33 3.34 lower L29056 1 750 2.6 639 100 0.3 116 3.35 3.36 center C0507 1 750 6.6 639 100 0.7 116 3.35 3.36 center C29056 1 650 9.0 539 100 0.9 117 3.37 3.38 u

er U0507 1 650 9.6 539 100 1.0 117 3.37 3.38 u

er U29056 1 730 10.0 619 100 1.0 124 3.51. 3.52 lower L04066 1 680 2.2 569 100 0.0 124 3.51. 3.52 lower L0607 1 580 4.0 469 100 0.1 125 3.53 3.54 center C04066 1 590 7.6 479 100 0.2 125 3.53 3.54 center C0607 1 630 7.0 519 100 0.1 126 3.55 3.56 u

er U04066 1 630 7.8 519 100 0.2 126 3.55 3.56 u

er U0607 1 580 8.7 469 100 0.2 i~[

Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 5 of 10 Table 1-2 includes the details for 24 experiments that had 300 flm of pre-transient oxide (shaded rows).

As requested, these points have not been included in Figure 1-1 since the amount by which the quench temperature would be reduced, to determine an equivalent clean zirconium temperature from the data, for significant amounts of Zr02 has not been well established. There is no consensus in the literature regarding how thick the oxide must be before the impact on the minimum stable film temperature becomes significant. The statistics in Table 1-1 suggest there is no statistically significant difference in the quench temperatures as the initial oxide increases from 100 to 300 flm.

Dhir (Reference 1-7) acknowledges that the "effect of oxidation on quenching behavior is most difficult to quantify."

In several places Dhir states that the quenching temperature on oxidized zircaloy surfaces were 50 to 80 K higher than on fresh surfaces but does not indicate the amount of oxide required to cause this difference. Even if all the Hofmann 100 flm data points in Figure 1-1 were shifted downward by 80 K all data points would still be above the curve for clean zircaloy from the Shumway correlation.

This observation supports the conclusion that the Shumway correlation (as applied) is conservatively low for the intended applications.

Wendelstorf and others in Reference 1-8 applied a thin sheet approximation that shows how the presence of an oxide layer impacts the effective heat transfer coefficient (HTCeff) near the surface of the oxidized metal.

The work was motivated by the need to understand how oxide impacts the spray cooling of steel but the theory is applicable also to Zr and Zr02. For stainless steel Wendelstorf concludes that "the theoretical effect of thin homogeneous and adhesive oxide layers on heat transfer is significant only for layers of 100 flm thickness and above."

His conclusion is based on how much HTCeff is reduced as oxide increases. A similar statement can be made for Zr and Zr02 by adapting the approach used in Reference 1-8 to the fuel cladding geometry and the properties of Zr and Zr02. It should be noted that for a low convective heat transfer coefficient such as that for film boiling that the resistance of the Zr02 layer is not a major contributor to the overall thermal resistance from the fuel pellet surface to the coolant. For a high convective heat transfer coefficient such as that for nucleate boiling the presence of a Zr02 layer has a higher percentage impact on the overall thermal resistance but still produces relatively small absolute changes in the temperature difference from the fuel pellet surface to the coolant.

Figure 6 of Reference 1-1 included 61 data points from Peterson and Bajorek (Reference 1-3).

Of the total 61 data points, 24 were characterized as clean or unoxidized and 37 were labeled as oxidized.

Reference 1-3 focused on how oxidization changes the surfac'1 roughness and characterized the test samples in this way. No oxide thickness values were documented. For the 37 points that were labeled as oxidized samples, there were 13 points where the roughness values were more than a factor of three higher than the unoxidized values indicating the presence of substantial amounts of oxide.

These 13 points have been removed and are not present in Figure 1-1. All 24 of the original points for unoxidized samples have been retained.

Another 24 points for the so-called oxidized samples had average roughness values (1.6 flm) that were less than the unoxidized samples (1.7 flm). These samples were retained because they could not have had any significant amounts of oxide and still had such a low roughness. The two different data sets from Peterson and Bajorek independently support the suggestion from Wendelstorf that thin oxide layers do not significantly affect the overall heat transfer.

It is expected that the Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 6 of 10 lightly oxidized data from Reference 1-3 should have a slightly higher quench temperature (see Figure 1-1).

Figure 6 of Reference 1-1 included ten data points from GEAP-13112 (Reference 1-4).

The maximum stated oxide in the GEAP-13112 report was estimated as 1.8 mil (45.7 Jlm).

All GEAP-13112 points have been removed from Figure 1-1 but not because of the amount of oxide.

Although the quench temperatures do indicate the ability to rewet the dry cladding surface from an elevated temperature following a LOCA, quenching by spray from high-void conditions as used in the GEAP-13112 tests is not representative of the quenching that occurs in an ATWSI scenario.

It is for this reason that the ten data points from GEAP-13112 previously shown in Figure 6 of Reference 1-1 have been omitted from Figure 1-1.

For purposes of evaluating the modeling of Tmin for applicability to ATWSI originating from MELLLA+ conditions, the most representative zircaloy data is that from the Halden experiments (References 1-5 and 1-6). Because the GEH implementation of the Shumway correlation does not credit void fraction or oxidation, the two most important parameters for Tmin applicability are the pressure and wall material property.

Most data shown in Figure 1-1 are at low pressures relative to a MELLLA+ ATWSI analysis. Because no depressurization is expected in an ATWSI event, the pressure range is approximately 7 to 8 MPa. The Halden data were recorded for fluid pressures ranging from 6.5 to 6.9 MPa using a zircaloy BWR fuel rod segment.

Also, the average heat fluxes in the Halden tests correspond well to those expected in an ATWSI scenario after the power is reduced by reducing core flow. Boiling transitions experienced in the Halden tests were a result of the low flow, which is the same causal mechanism for boiling transition during an ATWSI. The cooling as liquid flow was suddenly restored in the tests also emulates the cooling that occurs when flow upsurges during an ATWSI flow oscillation. These conditions in a BWR fuel channel are generic for ATWSI power/flow conditions where large oscillations can occur. The only distinction being that the more reactive control rod line for MELLLA+ used in the plant calculations is more likely to result in higher channel power and earlier onset of instability as the core flow is reduced.

All of the Halden data described and presented in Reference 1-1 has been retained here in Figure 1-1 because it is judged, based on the discussion above, that the Halden test conditions are the most representative of the conditions expected in an ATWSI scenario for MELLLA+ conditions once the power and flow oscillations grow to the point that boiling transitions occur and could result in cladding temperatures that approach or exceed Tmin.

There is no indication in the Halden reports how much oxide accumulated during the tests. The accumula'ted amount has been calculated by considering the number of boiling transition (BT) events, the maximum temperature for each event, and the duration of each event for each rod segment. The amount of oxide produced during a BT event averaged 2.4 Jlm with a minimum to maximum range of 0.2 to 6.9 Jlm. The highest value was calculated for a segment conservatively assumed to have zero initial oxide. The maximum accumulated oxide for the series of tests was less than 50 Jlm for the rod segment that experienced the most BT events.

These calculated numbers should be considered as rough estimates to support the conclusion that the accumulated oxide amounts were not excessive and thus the Halden data points support the conclusion that the Shumway correlation as applied is conservative. Note that even the minimum Halden data point is 166 K above what is predicted by the Shumway correlation for unoxidized zircaloy.

Non-Proprietary Infonnation - Class I (Public)

GEH-GGNS-AEP-636 Page 7 of 10

\\

In Figure 1-1, the solid red curve obtained from the Shumway correlation using zircaloy material properties is below essentially all of the zircaloy TQ values extracted from References 1-2 through 1-6. The data supports the conclusion that the Shumway correlation is conservative for the intended applications in the TRACG code.

There are several plausible explanations (not related to oxide) for why the Shumway correlation is conservatively lower than the bulk of the data.

For the correlated curve, the Reynolds number was assumed to be zero because the experiments did not provide sufficient infonnation to detennine the experimental flow; however, the Reynolds number dependence is small in the Shumway correlation and accounting for it would not affect the conclusion that the Shumway correlation is conservative for the intended applications. The Shumway correlation (solid red curve) was also evaluated assuming that a = 1 so no credit would be realized from the tenn [1 +(1-a )2] in the correlation. This tenn has been judged to have inadequate experimental support because in Shumway's words it is based on "a small amount of unpublished Semiscale void data" and the "accuracy of the void effect is untested".

Especially for t!J.e cases of the Hofmann and Halden data the quench occurs for a much lower void fraction than 1.0 just based on how the liquid water was forced into the test section. It is also likely that a credit for liquid subcooling is observed in the data that is not represented in the Shumway correlation. As an upper bound on the temperature prediction from the Shumway correlation, a value of a = 0 was assumed to obtain the dashed red curve in Figure 1-1. The dashed curve is in reasonable agreement with the Hofmann and Halden quench temperature data; however, in applications of the Shumway correlation in TRACG analyses the tenn [1 +(1-a )2] is conservatively replaced by 1.0 because of the inadequate experimental support for this tenn.

Summary The Shumway correlation for Tmin properly accounts for a wide range of material properties and water pressures as evidenced by the comparisons to data in Figure 6 of Reference 1-1.

As requested, the collaborating data for other materials has been removed from this document leaving only zircaloy. All the zircaloy data points from Figure 6 of Reference 1-1 were reviewed to evaluate if they were applicable for the intended purpose of supporting the use of the Shumway correlation for unoxidized zircaloy to calculate Tmin used in ATWSI calculations. The zircaloy data from GEAP-13112 (Reference 1-4) was excluded because quenching occurred by spray cooling into a steam environment from above whereas quenching in an ATWSI occurs by liquid water.

The thickness of the zirconium dioxide (Zr02) that was initially present in the specimens or that accumulated during the tests was also considered. The data points that were retained contained a total accumulated Zr02 layer of less than 120 J.lm. All the Hofmann data (Reference 1-2) traces were carefully scrutinized to ensure proper recording of the quench temperatures.

Hofmann data obtained from specimens with an initial 300 J.lm Zr02 layer was removed even though this data does not indicate an increase in quench temperatures relative to the data obtained from the samples where the initial Zr02 layer was 100 J.lm. The Peterson and Bajorek (Reference 1-3) data with roughness values above the clean zircaloy roughness values were also removed because high roughness values imply a thick Zr02 layer that was not quantified by the researchers. The remaining zircaloy data was plotted in Figure 1-1 along with two examples of the Shumway correlation for zircaloy properties.

Shumway at 0% voids corresponding to liquid water quench provides reasonable agreement with the Hofmann and Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 Page 8 of 10,

Halden (References 1-5 and 1-6) data; nevertheless, the more conservative form of the Shumway correlation without crediting the void term is what is used in TRACG to estimate Tmin for zircaloy.

This implementation is justified because it provides a value of Tmin that is lower than most of the zircaloy data as shown in Figure 1-1.

Lower values of Tmin are more conservative because they delay the return to nucleate boiling and thus result in higher and more conservative calculated values for the wall temperature (Tw).

((

))

Figure 1-1 References Shumway Correlation Compared to Zircaloy Data versus Pressure 1-1 Use of the Shumway Tmin correlation with Zircaloy for TRACG Analyses, Letter J.F.

Harrison (GEH) to NRC Document Control Desk, MFN 13-073 (ADAMS Accession No. MLI3253AI05), September 9,2013.

1-2 Hofmann, P. et aI., Quench Behavior of Zircaloy Fuel Rod Cladding Tubes: Small-Scale Experiments and Modeling of the Quench Phenomena, FZKA 6208, Forschungszentrum Karlsruhe, March 1999.

1-3 Peterson, L.J. and S.M. Bajorek; Experimental Investigation of Minimum Film Boiling Temperature for Vertical Cylinders at Elevated Pressure; Proceedings of leONE10 1ath; Arlington, VA; April 14-18, 2002.

1-4 Duncan, J.D. and J.E. Leonard, Thermal Response and Cladding Performance of an Internally Pressurized Zircaloy-Clad Simulated BWR Fuel Bundle Cooled by Spray Under Loss-of-Coolant Conditions, GEAP-13112, April 1971.

1-5 McGrath, M., Minutes of the Fourth Workshop on Dry-out Fuel Behaviour Tests (IFA-613), HWR-499, OECD Halden Reactor Project, April 1997.

Non-Proprietary Infonnation - Class I (Public)

GEH-GGNS-AEP-636 Page 9 of 10 1-6 Ianiri, R., The Third Dryout Fuel Behaviour Test Series in IFA-613, HWR-552, GECD Halden Reactor Project, February 1998.

1-7 Dhir, V.K. et aI., Quenching Studies on a Zircaloy Rod Bundle, Journal of Heat Transfer, Vol. 103, pp. 293-299, May 1981.

1-8 Wendelstorf, R. et aI., Effect of Oxide Layers on Spray water Cooling Heat Transfer at High Surface Temperatures, Journal of Heat and Mass Transfer, Vol. 51, pp. 4892-4901, 2008.

Non-Proprietary Information - Class I (Public)

GEH-GGNS-AEP-636 RAI2 Page 10 of 10 Section 9.3.3 ofAttachment 10 states:

The plant-specific ATWS stability calculation was performed using the NRC-approved neutronic and thermal-hydraulic codes... TRACG04.

An error in the code was corrected by letter from GE Hitachi Nuclear Energy to the staff dated October 15, 2013 titled "Updated TRACG Quench Front Model Description and Qualification", which is currently under staff review.

In the October 15, 2013 letter, GE noted:

The quench front model has been updated to correct an error in the quench front heat transfer coefficient for bottom rejlo0 ding, and to better capture the heat transfer ahead ofand behind the quenchfront.

Please clarify which quench model is being used in the application.

GEM Response The ATWSI cases documented in Section 9.3.3 of the M+SAR were performed with the corrected quench model described in the letter from James F. Harrison (GEH) to the NRC Document Control

Desk, "Updated TRACG Quench Front Model Description and Qualification," MFN-13-085, October 15,2013.

to GNRO-2014/00024 GEH Affidavit for Enclosure 1

GE-Hitachi Nuclear Energy Americas LLC AFFIDAVIT I, Peter M. Yandow, state as follows:

(1)

I am the Vice President, NPP/Services Licensing, Regulatory Affairs, GE-Hitachi Nuclear Energy Americas LLC ("GEH"), and have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld, and have been authorized to apply for its withholding.

(2)

The information sought to be withheld is contained in Enclosure 1 of GEH letter, GEH-GGNS-AEP-636, "GEH Responses to MELLLA+

Requests for Additional Information," dated March 4, 2014.

The GEH proprietary information in Enclosure 1, which is entitled "Responses to Requests for Additional Information in Support of GGNS MELLLA+ LAR," is identified by a dotted underline inside double square brackets.

((It\\i~.

~~}.)J~.J)._<;~j~__~JJ.~~~mp.l~~~~?.J]

Figures and large objects are identified with double square brackets before and after the object.

In each case, the superscript notation

{3} refers to Paragraph (3) of this affidavit, which provides the basis for the proprietary determination.

(3)

In making this application for withholding of proprietary information of which it is the owner or licensee, GEH relies upon the exemption from disclosure set forth in the Freedom ofInformation Act ("FOIA"), 5 U.S.C. Sec. 552(b)(4), and the Trade Secrets Act, 18 U.S.C.

Sec. 1905, and NRC regulations 10 CFR 9.17(a)(4), and 2.390(a)(4) for trade secrets (Exemption 4). The material for which exemption from disclosure is here sought also qualifies under the narrower definition of trade secret, within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975 F.2d 871 (D.C. Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F.2d 1280 (D.C. Cir. 1983).

(4)

The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs (4)a. and (4)b. Some examples of categories of information that fit into the definition ofproprietary information are:

a.

Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by GEH's competitors without license from GEH constitutes a competitive economic advantage over other companies; b.

Information that, if used by a competitor, would reduce their expenditure of resources or improve their competitive position in the

design, manufacture,
shipment, installation, assurance ofquality, or licensing of a similar product; c.

Information that reveals aspects of past, present, or future GEH customer-funded development plans and programs, resulting in potential products to GEH; d.

Information that discloses trade secret or potentially patentable subject matter for which it may be desirable to obtain patent protection.

Affidavit for GEH-GGNS-AEP-636 Page 1 of3

GE-Hitachi Nuclear Energy Americas LLC (5)

To address 10 CFR 2.390(b)(4), the information sought to be withheld is being submitted to NRC in confidence. The information is of a sort customarily held in confidence by GEH, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by GEH, not been disclosed publicly, and not been made available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary or confidentiality agreements that provide for maintaining the information in confidence. The initial designation of this information as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in the following paragraphs (6) and (7).

(6)

Initial approval of proprietary treatment of a document is made by the manager of the originating component, who is the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge, or who is the person most likely to be subject to the terms under which it was licensed to GEH.

(7)

The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist, or other equivalent authority for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside GEH are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary or confidentiality agreements.

(8)

The information identified in paragraph (2), above, is classified as proprietary because it contains detailed results and conclusions regarding supporting evaluations of the safety-significant changes necessary to demonstrate the regulatory acceptability of the Maximum Extended Load Line Limit Analysis Plus analysis for a GEH Boiling Water Reactor

("BWR"). The analysis utilized analytical models and methods, including computer codes, which GEH has developed, obtained NRC approval of, and applied to perform evaluations of Maximum Extended Load Line Limit Analysis Plus for a GEH BWR.

The development of the evaluation processes along with the interpretation and application of the analytical results is derived from the extensive experience and information databases that constitute a major GEH asset.

(9)

Public disclosure of the information sought to be withheld is likely to cause substantial harm to GEH's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of GEH's comprehensive BWR safety and technology base, and its commercial value extends beyond the original development cost.

The value of the technology base goes beyond the extensive physical database and analytical methodology and includes development of the expertise to determine and apply the appropriate evaluation process. In addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.

Affidavit for GEH-GGNS-AEP-636

': Page 2 of3

GE-Hitachi Nuclear Energy Americas LLC The research, development, engineering, analytical and NRC review costs comprise a substantial investment of time and money by GEH. The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial. GEH's competitive advantage will be lost if its competitors are able to use the results of the GEH experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to GEH would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive GEH of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing and obtaining these very valuable analytical tools.

I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.

Executed on this 4th day ofMarch 2014.

Peter M. Yandow Vice President, NPP/Services Licensing Regulatory Affairs GE-Hitachi Nuclear Energy Americas LLC 3901 Castle Hayne Road Wilmington, NC 28401 Affidavit for GEH-GGNS-AEP-636 Page 3 of3 IJ