ML14030A276

From kanterella
Jump to navigation Jump to search
Final Report: Characterization of Unionid Communities Near the Braidwood Nuclear Station Kankakee River Discharge Location
ML14030A276
Person / Time
Site: Braidwood  
(NPF-072, NPF-077)
Issue date: 01/31/2009
From:
Ecological Specialists
To:
Exelon Nuclear, Office of Nuclear Reactor Regulation
Shared Package
ML14030A308 List:
References
Braidwood-389, Exelon Nuclear 2009b, RS-14-029
Download: ML14030A276 (18)


Text

Cxelo, A/'&-Ifor 82O0'7b Final Report:

Characterization of Unionid Communities near the Braidwood Nuclear Station Kankakee River Discharge Location Prepared for:

Exelon Nuclear Braidwood, IL Prepared by:

Ecological Specialists, Inc.

O'Fallon, Missouri K

January 2009 (ESI Project No.08-023)

08-023 January 2009 Acknowledgements Exelon provided funding for this study. Mr. John Petro coordinated the project for Exelon. Mr. Eric Belt directed the study and was field team leader and primary author of the report for Ecological Specialists, Inc. (ESI). Mr. Kendall Cranney (ESI) was the dive team supervisor; Ms. Rebecca Winterringer (ESI) and Mr. Nathan Wurmb provided diving and field assistance. Mr. Eric Rahm assisted in report preparation.

i

08-023 January 2009 Table of Contents 1.0 Introduction.....................................................................................................................................................................

1 2.0 M ethods...........................................................................................................................................................................

2 3.0 Results.............................................................................................................................................................................

3 4.0 Discussion.......................................................................................................................................................................

4 5.0 Literature Cited...............................................................................................................................................................

6 Figures Figure 2-1. Live unionids collected along sampling transects and qualitative and quantitative sample locations in the Kankakee River near the Braidwood Nuclear Station discharge location, October 2008...........................

9 Figure 3-1. Depth (m) and substrate observed along unionid sampling transects in the Kankakee River near the Braidwood N uclear Station discharge location, October 2008.................................................................

10 Tables Table 1-1. Unionids collected near the Braidwood Nuclear Station outfall for this and a recent study, Illinois, Kankakee River, 2008.....................................................................................................................................................

12 Table 3-1. Characteristics of unionids collected near the Braidwood Nuclear Station outfall, Illinois, Kankakee River, October 2008..................................................................................................................................................

13 Table 3-2. Depths, substrate, and number of live unionids collected along sample transects near Braidwood, Illinois, Kankakee River.............................................................................................................................................

14 ii

08-023 January 2009 1.0 Introduction Exelon's Braidwood Nuclear Station (Braidwood) is considering constructing a diffuser pipe across the Kankakee River to replace their existing discharge canal. A recent survey for unionids (freshwater mussels) in the Kankakee River near the proposed diffuser pipe location indicated unionids are present (HDR, 2008). However, the unionid survey was conducted with a mussel brail., which is useful for indicating the presence or absence of unionids, but does not yield adequate information with respect to distribution and species composition (Dunn, 2000). Also, since no dive sampling was conducted in the previous study, unionid habitat in the survey area was not evaluated in areas with depths >2m (see HDR, 2008). Braidwood requires unionid disltribution and species composition information to determine if unionids can be avoided during construction and operation of the diffuser pipe, and if unionids cannot be avoided, determine species composition and density information that could be used for an evaluation and biological assessment by the Illinois Department of Conservation and/or U.S. Fish and Wildlife Service.

The Kankakee River harbors a diverse unionid community that includes Illinois listed species. The unionid study in August 2008 (see HDR, 2008) resulted in 14 live unionid species (Table 1-1 ), including two Illinois listed species (Cyclonaias tuberculata and Venustaconcha ellipsiformnis). In addition, shells of two other Illinois listed species were encountered (Elliptio dilatata and Plethobasus cyphyus [also a candidate for federal listing]). Results from this study will supplement previous findings and more specifically characterize the unionid community and distribution within the potential impact area.

In-stream construction activity may disrupt the substrate and, consequently, the animals living in the substrate. Unionids within the area directly affected by construction could be crushed by equipment or permanently buried under excavation spoil. Disruption of the substrate could result in displacement of unionids to unsuitable habitat, which could lead to reduced fitness or death. Construction activities could also lead to altered flow patterns that may increase sedimentation, which is a putative source of unionid declines throughout North America (Fuller, 1974; Aldridge et al., 1987; Williams ei al., 1993; Box and Mossa, 1999). Construction impacts to unionids have successfully been mitigated by minimizing the area used for constructing and relocating unionids from areas of unavoidable impact (Dunn el al., 2000).

Ecological Specialists, Inc. was contracted to survey for unionids within the potential impact area proposed for construction of the diffuser. The objective of this unionid study was to determine the distribution, species composition (specifically Illinois listed species), and density ofunionids from approximately 100m upstream to 100m downstream of the proposed diffuser pipe location. This report summarizes the results of the unionid survey and the habitat conditions found in the project area. Fieldwork was conducted 21-22 October 2008.

I

08-023 January 2009 2.0 Methods Semi-quantitative, quantitative, and qualitative sampling methods were used to evaluate the unionid community in the Kankakee River potentially impacted by construction of the diffuser. The objective of semi-quantitative sampling was to determine unionid distribution. For semi-quantitative sampling, five 200m transects were placed perpendicular to the flow starting approximately 20-40m upstream of the proposed diffuser (Figure 2-1). Transect I was positioned about 10m from the right descending bank (RDB) and Transects 2-5 were spaced approximately 15-30m across the width of the river adjacent to Transect I. A diver traversed each transect, collecting all unionids within Im of the line in l0m sections for a total of 20 samples per transect.

The objective of qualitative sampling was to estimate species richness, while quantitative sampling was used to determine unionid density, species abundance, adult to juvenile distribution, and live to shell ratio. The effort required to find protected species is often considerable and they are rarely collected by brailing or in quantitative samples (Kovalak el al., 1986). Five 10 min qualitative samples and five 0.25m 2 quantitative whole substrate samples were collected in areas with higher densities and/or where listed species were present (.see Figure 2-1).

Live unionids were identified, counted and recorded as adult or juvenile (Lampsilines and Anodontines _<3yrs, Amblemines <5yrs; external annuli count). Species designated in Illinois as endangered, threatened, or of special concern were measured (mm) and aged (external annuli count). Depth (m) and substrate (Wentworth scale) were also recorded at each semi-quantitative and quantitative sample. Since water and/or air temperature was low, animals were returned to the substrate as quickly as possible.

2

08-023 January 2009 3.0 Results A total of 126 live unionids of 13 species were collected during the survey: Actinonaias ligamenuina (n=97), Amblemna plicala (n= 3), C. tuberculata (n=1), Elliptio dilitata (n=2), Fusconaiaflava (n= 1), Lampsilis cardium (n=2), Lasinigona costata (n=1), Leptodeafragilis (n=2), Megalonaias nervosa (n=2), Quadrula metanevra (n=1), Quadrula p. puslulosa (n=l), Utterbackia imbecillis (n=1), V. ellipsiformnis (n=2) (Table 3-1). Two species (C. tuberculata, and E. dilatata) are listed as Endangered and one as a species of Special Concern (1/. ellipsiformis) by the IDNR. No juvenile unionids were observed.

Unionids were sparsely scattered throughout the survey area, however all listed species were collected in the upstream half of the survey area within 50m of the right descending bank (RDB) (see Figure 2-1). The three listed species were along Transect 1, about 10-15m off the RDB within an area approximately 5-20m upstream and 0-15m downstream of the proposed diffuser (see Figure 2-1). An average of 1.2 unionids were collected per lOin 2 sample over the study area.

Only one live unionid (A. ligainentina) was collected from the five qualitative samples within the area that appeared denser and where listed species were collected along transects. Quantitative samples within the same area resulted in an average of 0.80unionids/m 2. The CPUE (number live unionids collected per collector per hour of effort) from the five qualitative samples was 12.1. This study's CPUE is similar to the CPUE values calculated from the August survey (17.3 upstream and 10.3 downstream of the existing outfall canal) (HDR, 2008).

Habitat varied little throughout the survey area with exception of shallower depths near the banks. River habitat within the survey area was a run. Depths along Transects 1 and 5 ranged from 0.8-2.1m while depths along Transects 2-4 ranged from 1.5-3.7m (Table 3-2; Figure 3-1). Substrate was generally a mix of boulder, cobble, gravel and sand. In general, more boulder and less gravel was observed near the center of the river along Transects 3 and 4 (see Figure 3-1).

No obvious correlation between unionid presence and habitat characteristics was observed.

3

08-023 January 2009 4.0 Discussion Habitat with the survey area is not typically ideal for unionids within the Kankakee River. Run habitats within the Kankakee River, like the habitat within this study's survey area, are not known to harbor abundant and species-rich unionid communities. In a 1978 unionid survey of 13 sites within the Kankakee River, unionid communities in pools or runs generally ranked low in abundance and diversity compared to areas with riffles and areas below dams (Suloway, 1981). A unionid study at two sites on the Kankakee River conducted by ESI in 2002 showed that of the two sites sampled, the site with the riffle/run habitat resulted in twice as many species and 17 times more live unionids than the site with a run habitat (ESI, 2003). Although this study's survey area appears to harbor a relatively moderate to high species richness, unionid abundance (density) was relatively low and unionids were scattered throughout the site.

A total of 17 species were collected live in the study area, including the Illinois T&E species C. luberculata, E. dilatata, Illinois Special Concern species V. ellipsiformis, and the Federal Candidate species P. cyplhyus (see Table 1-1). Unionids were scattered throughout the site in a low density in both this and the HDR (2008) study. However, two areas of higher unionid densities were found; on the left descending bank (LDB) upstream of the diffuser location (see HDR, 2008) and on the RDB directly in-line with the proposed diffuser (see Figure 2-1 ). Species such as Lampsilis siliquoidea, Lasmigona complanata, and Pyganodon grandis, were primarily limited to the silty area near the LDB, upstream of the diffuser location, which is typical habitat for these species. The freshly dead shell of P. cyphvus was also found along the LDB upstream of the discharge canal. Most of the Illinois T&E species, however, were found on the RDB.

Although the survey area harbors a relatively species-rich unionid community, unionid density is relatively low and no recruitment was observed. The low abundance of unionids may be due to the general lack of suitable substrate. By and large, substrate throughout the site appeared stable but did not contain much area with finer particles (i.e., sand and gravel) into which the unionids can burrow. Also, no juvenile unionids were observed suggesting little or no recruitment occurring within the survey area. Therefore, it is likely a denser, stable, and reproducing unionid community upstream, probably in a riffle habitat, seeds the study area. However, Illinois listed unionid species were present, and therefore impacts to unionids by construction and operation of the diffuser within the area should be minimized.

To limit impact on the unionid community, the diffuser should avoid the area within approximately 20m of the RDB and be placed at the most downstream angle allowed. Although unionids in this area are still relatively sparse, this area appeared to be the densest in general and harbored Illinois listed species. In addition, listed species are more likely present in areas where unionids are denser; and therefore, construction activities should avoid the area upstream of the current outfall canal along the left descending bank since results from the August survey suggest unionids also occur in higher densities in this area (see HDR, 2008).

4

08-023 January 2009 Since unionids were scattered throughout the survey area with no observable correlation of habitat to distribution, and Illinois listed species were encountered, listed species may occur throughout the survey area. Therefore, IDNR and USFWS should be consulted early in the permitting process to identify any Agency concerns with the diffuser construction and operation.

0 5

0 8-02 3 January 2009 5.0 Literature Cited Aldridge, D. W., B. S. Payne, and A. C. Miller. 1987. The effects of intermittent exposure to suspended solids and turbulence on three species of freshwater mussels. Environmental Pollution 45:17-28.

Box, J. M., and J. Mossa. 1999. Sediment, land use, and freshwater mussels: prospects and problems. Journal of the North A4merican Benthological Society 18:99-117.

Dunn, H. L. 2000. Development of strategies for sampling freshwater mussels (Bivalvia: Unionidae). Pages 161 to 168 in R. A. Tankersly, P. I. Warmolts, B. J. Armitage, P. D. Johnson, and R. S. Butler (eds.). Freshwater Mollusk Symposium Proceedings. Ohio Biological Survey, Columbus, OH. 274pp.

Dunn, H. L., B. S. Sietman, D. E. Kelner. 2000. Evaluation of recent Unionid (Bivahlia) relocations and suggestions forfiuture relocations and reintroductions. Proceedings of the first Freshwater Mollusk Conservation Society Symposium 1999.

Ecological Specialists, Inc. 2003. Unionid AMussel Survey of the Kankakee River at Two Proposed W"ater Intake Sites for the City of Joliet, Illinois. Prepared for EA Engineering, Science, and Technology. 19pp.

Fuller, S. L. H. 1974. Clams and Mussels (Mollusca: Bivalvia). Pages 215-273 in C. W. Hart and S. L. H. Fuller (eds).

The Pollution Ecology offreshi'ater Invertebrates. Academic Press, New York, USA.

HDR Engineering, Inc. 2008. Investigations to Determine Presence of State-Listed Species of Fish and Freshwater AMussels in the Kankakee River Near the Braidwood Nuclear Station W"armwater Discharge Channel. Prepared for Exelon Nuclear. 21 pp.

Illinois Endangered Species Protection Board. 2006. http://dnr.state.il.us/espb/datelist.htm Kovalak W. P., S. D. Dennis, J. M. Bates. 1986. Sampling effort required to find rare species offreshwater mussels.

Pages 46-59 in Isom BG. (ed) Rationale for Sampling and Interpretation of Ecological Data in the Assessment of Freshwater Ecosystems. American Society for Testing and Materials, Special Technical Publication No. 894.

Suloway, L. 1981. The Unionid (A'Iollusca: Bivalvia) Fauna of the Kankakee River in Illinois. The American Midland Naturalist 105 (2):233-239.

6

08-023 January 2009 Turgeon, D. D., J. F. Quinn, Jr., A. E. Bogan, E. V. Coan, F. G. Hochberg, W. G. Lyons, P. M. Mikkelsen, R. J. Neves, C. F. E. Roper, G. Rosenberg, B. Roth, A. Scheltema, F. G. Thompson, M. Vecchione and J. D. Williams.

1998. Common and scientific names of aquatic invertebrates from the United States and Canada: Mollusks.

2nd Edition. American Fisheries Society Special Publication 26, Bethesda Maryland. 526pp.

Wentworth, C. K. 1922. A scale of grade and class terms for clastic sediments. Journal of Geology 30:377-392.

Williams, J. D., M. L. Warren, Jr., K. S. Cummings, J. L. Harris, and R. J. Neves. 1993. Conservation status of freshwater mussels of the United States and Canada. Fisheries 18:6-22.

7

08-023 January 2009 Figures 8

'C 0o 009 0-0,)

ECOLOGICAL SPECIALISTS. INC.

Figure 2-1. Live unionids collected along sampling transects and qualitative and quantitative sample locations in the Kankakee River near the Braidwood Nuclear Station discharge location, October 2008.

To "[

0

0i 00 Go tj 0

08-023 January 2009 Tables II

08-023 January 2009 Table 1-I. Unionids collected near the Braidwood Nuclear Station outfall for this and a recent study, Illinois, Kankakee River, 2008.

Number Live' Number Live Collected Live (HDR, 2008)

(this study)

(ESI, 2008, HDR, 2008)

SPecies 2

Alasmidonta marginata D

0 Actinonaias ligamentina 115 97 X

Amblema plicata 28 13 X

Cyclonaias tuberculata (T)3 3

1 X

Elliptio dilatata (T)

R 2

X Fusconaiaflava WD 1

X Lampsilis cardium 3

2 X

Lampsilis siliquoidea 5

0 X

Lasmigona complanata 10 0

X Lasinigona costata 13 1

X Leptodeafragilis 3

2 X

Ligumia recta D

0 Megalonaias nervosa D

2 X

Plethobasus cyphus (E)

D 0

Pleurobeina sintoxia 5

0 X

Potamilus alatus D

0 Pyganodon grandis 3

0 X

Quadrula inetanevra 2

1 X

Quadrula p. pustulosa 12 1

X Strophitus undulatus D

0 Utterbackia imbecillis 7

1 X

Veinustaconcha ellipsiformis (SC) 1 2

X Total Live 210 126 Total Number of Live Species 14 13 Total Number of Live Species for Both Studies 17

'D=collected only a fresh-dead shell: R=collected as a relic shell (HDR, 2008) 2Turgeon et al.. 1998

'T=Illinois state-threatened: E=Illinois state-endangered; SC=lllinois Special Concern species (IESPB, 2006) 12

08-023 January 2009 Table 3-1. Characteristics of unionids collected near the Braidwood Nuclear Station outfall, Illinois, Kankakee River, October 2008.

Number Live Abundance

% Adult

% Juvenile' Age Length (annuli count)

(mm)

Species 2

Actinonaias ligamentina 97 77.0 100.0 0.0 Amblena plicata 13 10.3 100.0 0.0 Cyclonaias tuberculata (T)3 1

0.8 100.0 0.0 18 93 Elliptio dilatata (T) 2 1.6 100.0 0.0 13/15 100/90 Fusconaiaflava 1

0.8 100.0 0.0 Lanipsilis cardiutm 2

1.6 100.0 0.0 Lasmigona costata 1

0.8 100.0 0.0 Leptodeafragilis 2

1.6 100.0 0.0 Megalonaias netriosa 2

1.6 100.0 0.0 Quadrula inetanevra 1

0.8 100.0 0.0 Quadrula p. pustulosa 1

0.8 100.0 0.0 Utterbackia imbecillis 1

0.8 100.0 0.0 Venustaconcha ellipsiformis (SC) 2 1.6 100.0 0.0 15/17 72/76 Total Live 126 Total Number of Live Species 13

'Lampsilines and Anodontines _3yrs, Ambleniines _5yrs 2Turgeon et al.. 1998

-T=lllinois state-threatened; SC=1llinois Special Concern species 13

08-023 January 2009 Table 3-2. Depths, substrate, and number live unionids collected along sample transects near Braidwood, Illinois, Kankakee River. (page 1 of 2)

Distance Along Transect (m)

Substrate (%)

No. Live Transect Min.

Max.

Unionids Depth (m)

Bedrock Boulder Cobble Gravel Sand Silt Clay 0

10 2

1.2 0

50 0

25 25 0

0 10 20 1

1.2 0

25 25 25 25 0

0 20 30 1

1.2 0

50 20 20 10 0

0 30 40 7

1.5 0

50 25 10 15 0

0 40 50 2

1.5 30 40 0

10 20 0

0 50 60 0

1.5 0

50 30 10 10 0

0 60 70 3

1.5 0

50 30 10 10 0

0 70 80 0

1.5 0

50 30 10 10 0

0 80 90 4

2.1 0

0 30 30 30 10 0

90 100 1

1.8 0

25 25 25 25 0

0 100 110 3

1.8 0

75 10 10 5

0 0

110 120 2

1.5 0

75 10 10 5

0 0

120 130 1

1.5 0

10 20 20 50 0

0 130 140 3

1.5 0

10 30 30 30 0

0 140 150 0

1.5 0

70 10 10 10 0

0 150 160 0

1.5 0

60 10 10 10 10 0

160 170 0

1.5 0

25 0

25 25 25 0

170 180 1

1.5 0

10 25 25 25 15 0

180 190 0

1.5 0

60 20 10 10 0

0 190 200 3

1.2 0

80 10 5

5 0

0 2

0 10 7

1.5 0

50 20 20 10 0

0 10 20 0

1.5 0

50 20 20 10 0

0 20 30 3

1.5 0

50 20 20 10 0

0 30 40 0

3.0 0

0 10 20 70 0

0 40 50 2

3.0 0

0 0

0 100 0

0 50 60 0

3.0 50 0

0 0

50 0

0 60 70 2

3.0 0

50 0

40 10 0

0 70 80 0

2.4 0

30 30 30 10 0

0 80 90 1

1.5 0

30 30 30 10 0

0 90 100 5

2.4 0

30 30 30 10 0

0 100 110 4

3.0 0

30 30 30 10 0

0 110 120 4

2.7 0

20 0

30 50 0

0 120 130 0

3.0 0

0 0

0 100 0

0 130 140 0

3.0 0

0 0

20 80 0

0 140 150 1

3.0 100 0

0 0

0 0

0 150 160 n/a n/a n/a n/a n/a n/a n/a n/a n/a 160 170 4

3.0 0

40 30 20 10 0

0 170 180

  • 2 2.4 0

50 20 0

30 0

0 180 190 1

2.4 0

10 30 30 30 0

0 190 200 5

2.4 0

20 40 10 40 0

0 3

0 10 0

3.4 0

60 20 10 10 0

0 10 20 4

3.4 0

60 20 10 10 0

0 20 30 1

3.4 0

50 10 10 30 0

0 30 40 0

3.4 0

50 10 10 30 0

0 40 50 0

3.4 0

50 10 10 30 0

0 50 60 0

3.4 0

50 10 10 30 0

0 60 70 0

3.2 0

50 10 10 30 0

0 70 80 1

3.0 0

50 30 0

20 0

0 80 90 1

3.0 0

50 30 0

20 0

0 90 100 1

3.7 0

50 20 0

30 0

0 14

08-023 January 2009 Table 3-2. Depths, substrate, and number live unionids collected along sample transects near Braidwood, Illinois, Kankakee River. (page 2 of 2)

Distance Along Transect (m)

Substrate (%)

No. Live Transect Min.

Max.

Unionids Depth (m)

Bedrock Boulder Cobble Gravel Sand Silt Clay 3 (cont.)

100 110 5

3.7 0

20 20 0

30 0

0 110 120 2

3.4 0

30 40 0

20 0

0 120 130 1

3.4 0

30 40 0

20 0

0 130 140 2

3.0 0

30 40 0

20 0

0 140 150 0

3.0 0

50 20 0

30 0

0 150 160 0

3.7 0

50 20 0

30 0

0 160 170 2

3.7 0

50 20 0

30 0

0 170 180 0

3.7 0

70 30 0

0 0

0 180 190 0

3.4 0

20 50 0

30 0

0 190 200 0

3.4 0

50 0

0 50 0

0 4

0 10 0

2.4 0

50 30 10 10 0

0 10 20 2

2.4 0

50 30 10 10 0

0 20 30 1

2.4 0

50 30 10 10 0

0 30 40 0

2.4 0

50 30 10 10 0

0 40 50 1

2.4 0

30 50 10 10 0

0 50 60 1

2.7 90 0

0 10 0

0 0

60 70 0

2.7 0

20 50 10 20 0

0 70 80 0

2.7 0

20 50 10 20 0

0 80 90 2

2.7 0

20 50 30 0

0 0

90 100 0

2.7 0

20 40 30 10 0

0 100 110 0

3.0 0

0 30 60 10 0

0 110 120 0

3.0 0

0 10 80 10 0

0 120 130 0

2.1 0

40 30 20 10 0

0 130 140 1

2.1 0

20 50 20 10 0

0 140 150 0

1.8 0

50 30 10 10 0

0 150 160 1

n/a 0

50 30 10 10 0

0 160 170 0

1.5 0

60 30 10 0

0 0

170 180 0

2.1 0

50 20 20 10 0

0 180 190 0

2.1 0

50 20 20 10 0

0 190 200 0

2.1 0

50 20 20 10 0

0 5

0 10 3

1.2 0

50 20 10 20 0

0 10 20 1

1.2 0

50 20 10 20 0

0 20 30 5

1.5 0

50 20 10 20 0

0 30 40 0

1.5 0

50 30 10 20 0

0 40 50 1

1.5 0

30 30 10 30 0

0 50 60 0

2.1 0

30 30 10 30 0

0 60 70 0

1.5 0

30 30 10 50 0

0 70 80 0

1.5 0

40 30 10 20 0

0 80 90 0

1.2 20 30 20 20 10 0

0 90 100 0

1.2 0

40 20 20 20 0

0 100 110 0

1.2 0

40 20 20 20 0

0 110 120 2

1.2 0

30 30 10 30 0

0 120 130 0

0.9 0

30 30 10 30 0

0 130 140 0

0.8 0

30 30 10 30 0

0 140 150 1

0.8 0

40 20 10 30 0

0 150 160 1

0.8 0

30 30 20 20 0

0 160 170 0

0.8 0

50 20 20 10 0

0 170 180 0

0.8 0

50 20 20 10 0

0 180 190 2

0.8 0

50 20 20 10 0

0 190 200 0

0.8 0

50 20 20 10 0

0 15