ML14030A267

From kanterella
Jump to navigation Jump to search
Investigations to Determine Presence of State-Listed Species of Fish and Freshwater Mussels in the Kankakee River Near the Braidwood Nuclear Station Warmwater Discharge Channel
ML14030A267
Person / Time
Site: Braidwood  
Issue date: 10/31/2008
From:
HDR Engineering
To:
Exelon Nuclear, Office of Nuclear Reactor Regulation
Shared Package
ML14030A308 List:
References
RS-14-029
Download: ML14030A267 (34)


Text

INVESTIGATIONS TO DETERMINE PRESENCE OF STATE-LISTED SPECIES OF FISH AND FRESHWATER MUSSELS IN THE KANKAKEE RIVER NEAR THE BRAIDWOOD NUCLEAR STATION WARMWATER DISCHARGE CHANNEL Prepared for EXELON NUCLEAR Braidwood, IL HDR Engineering, Inc.

10207 Lucas Drive Woodstock, IL 60098 October 2008

Braidwood Nuclear Station State-listed Species Investigation Table of Contents 1.0 Introduction...........................................................................................................................

1 1.1 Background..........................................................................................................................

1 1.2 Objectives.............................................................................................................................

2 2.0 M ethods...................................................................................................................................

2 2.1 Fish Sampling......................................................................................................................

2 2.1.1 Electrofishing........................................................................................................

2 2.1.2 Seining...........................................................................................................................

3 2.1.3 Sample Processing.....................................................................................................

3 2.1.4 W ater Quality M easurements...................................................................................

4 2.2 M ussel Sampling....................................................................................................................

4 3.0 Results and Discussion.......................................................................................................

9 3.1 Fish Survey..........................................................................................................................

9

3. 1.1 Electrofishing........................................................................................................

9 3.1.2 Seining........................................................................................................................

10 3.1.3 W ater Quality..............................................................................................................

10 3.2 M ussel Survey....................................................................................................................

11 4.0 Sum m ary.............................................................................................................................

18 5.0 References............................................................................................................................

20 i

Rrnidfwnnf AT.rionr Vtntin.

1.0 INTRODUCTION

1.1 BACKGROUND

Exelon Generation Company is proposing to replace the existing Braidwood Nuclear Station Cooling Pond discharge (shoreline discharge channel) with a diffuser pipe placed on the bottom of the Kankakee River extending across the river near the location of the current discharge channel.

The exact location will be selected following a series of engineering tests to be conducted in the river.

A preliminary review of fish and freshwater mussel studies conducted in this general reach of the river indicated that fish monitoring, including the proposed area for diffuser pipe placement, has been conducted annually for the past 30 years (with the exception of 1980)(HDRILMS, 2008); but that, while several freshwater mussel surveys had been conducted in the river between Kankakee and Wilmington in the past, none had been conducted at the proposed site.

The historical fisheries data indicate that pallid shiner (Notopis amnis) and river redhorse (Moxostoma carinatum), which are currently listed as endangered and threatened, respectively, by the state of Illinois, have been collected in this vicinity over the period of record.

No fish species currently listed as threatened or endangered by the Federal government were collected during the past 30 years.

The Kankakee River supports some of Illinois' most diverse and abundant mussel populations with 27 extant and 40 historical species (Cummings and Mayer 1997; Tiemann et al. 2007). It was surveyed several times for mussels in the 20th century including: 1909 (Wilson and Clark 1912); 1956 and 1960 (M.R. Matteson unpublished; INHS Mollusk Collection); and 1978 (Suloway 1981). Page et al. (1992) regard the mussel populations of the Kankakee River to be of national importance.

Several freshwater mussel species currently listed as either endangered or threatened by the state of Illinois were collected during these earlier surveys. No freshwater mussel I

Rn*,*A

  • nh.ln 1-nt-f;
  • tnfo-l;efo,* *no*.;oe lnl,*el';rrnt;nn species currently listed as threatened or endangered by the Federal government has been reported in this reach of the Kankakee River (Kramer, personal communication, 2008).

1.2 OBJECTIVES Field sampling programs were designed to collect both fish and freshwater mussels in the vicinity of the proposed diffuser site with the objectives of describing these aquatic communities and determining presence/absence of state-listed species. These data can be used to help determine whether conservation will be needed during the temporary construction disturbance and/or the permanent displacement of habitat by the diffuser pipe.

2.0 METHODS 2.1 FISH SAMPLING The fisheries component of the special studies described in this report searched for state-listed aquatic species in the vicinity of the Braidwood Nuclear Station intake and discharge using electrofishing and seining. Sampling was conducted in conjunction with the summer fish monitoring program that has been conducted annually since 1977 (excluding 1980 when sampling was not conducted).

Methods were consistent with the long-term monitoring program to provide a basis for comparison to the historic data base, if necessary.

2.1.1 ELECTROFISHING Electrofishing was conducted using a boat-mounted boom-type electrofisher utilizing a 5000-watt, 230-volt-AC, 10-amp, three-phase Model GDP-5000 Multiquip generator equipped with volt/amp meters and a safety-mat cutoff switch.

The electrode array consisted of three pairs of stainless steel cables (1.5-m long, 6.5 mm in diameter) arranged 1.5-m apart and suspended perpendicular to the longitudinal axis of the boat 1.5-m off the bow. Each of the three electrodes was powered by one of the phases. Electrofishing samples were collected on 4 August 2008.

Im 2

Rrnidwnnd Nurivar.4tntinn

.qtntp.li*tpd.qnprla* Inmo*flontinn Sampling was conducted at five locations in the Kankakee River and at one site in Horse Creek (Location 2; Figure 2-1). Each sampling location (except Location 2) consisted of two stations, designated by the location number and "R" or "L", indicating the right or left side of the river as one looks upstream (Figure 2-1 & Table 2-1). Electrofishing was conducted for 30 minutes along the shoreline on each side of the river at each sampling location. Because of the close proximity of Locations 3 and 4 of the monitoring program, sampling boundaries for those locations are smaller and sampling duration is reduced accordingly to 15 minutes. In addition, Location 2 was blocked by a large tree that had fallen across the middle of the sampling area prohibiting sample collection on the upper reach. of the sampling _area. As a result, sampljng at__this. location was reduced to 15 minutes. Electrofishing was conducted such that the first "run" at each location was in a downstream direction through the middle of the shocking zone. The second "run" was conducted in an upstream direction, adjacent to the first "run" and as close to the bank as water depth allowed. The third "run", if necessary, was made in a downstream direction outside of, but adjacent to, the two previous runs (Figure 2-2). Sampling was restricted to the hours between one-half hour after sunrise to one-half hour before sunset.

2.1.2 SEINING Shoreline seining was used as a second collection method at each sampling location. Seine samples were collected on 5 August 2008. Seine dimensions were 25 ft by 4 ft of 3/16-inch ace mesh, with a 4-ft by 4-ft bag of 3/16-inch ace mesh. Two seine hauls were made at each station (Figure 2-1). Each haul was made in a upstream direction covering approximately 15 meters of shoreline, with the second haul being conducted upstream of the first. An additional seine haul was made at location 4L. Seining was restricted to the hours commencing one-half hour after sunrise to one-half hour before sunset.

2.1.3 SAMPLE PROCESSING All state-listed fish (i.e., pallid shiner and river redhorse) were identified and enumerated.

River redhorse specimens were measured for total length (mm) and weighed (g) individually.

Rn 3

R-;A-"J AT QM14-

  • tnte.lleto*l *nerlee l.voeHon*..

Rrni~u~nn MueloarVtn Han tato.icto Q-ori*o Innfdfltion 2.1.4 WATER QUALITY MEASUREMENTS Three physicochemical parameters (temperature, dissolved oxygen [DO], and pH) were measured in conjunction with the sampling program. These data were collected prior to each sampling effort. Additionally, conductivity was measured prior to each electrofishing collection. All of the physicochemical measurements were taken at mid-depth in the water column.

Temperature (°C), dissolved oxygen (ppm), and conductivity (gmhos) were measured using an YSI Model 85 handheld oxygen, conductivity, salinity, and temperature meter. A Cole-Parmer pH Testerl was used to determine pH. All instruments were calibrated prior to the sampling event.

2.2 MUSSEL SAMPLING The Kankakee River at the Braidwood Station discharge channel was investigated for the presence of freshwater mussels on 8 August 2008.

Field crew consisted of Illinois Natural History Survey (INHS) personnel J.S. Tiemann, K.S. Cummings, C.A. Mayer, C.A. Phillips, A.R. Kuhns, J.L. Sherwood, and D.M. Ellington, as well as Chicago Academy of Science staff S. Clark. Sampling consisted of two phases (Strayer and Smith 2003). Phase I was hand-picking along shoreline (yellow area in Figure 2-3) by six people for 2.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, which is equivalent to 15 person-hours total.

During the time search, live individuals and valves of dead specimens were collected in a random manner, covering all substrate types. Phase 2 consisted of nine 220-m brail runs in the center of the river (red lines in Figure 2-3); the brail was retrieved several times throughout the length of a run to check for mussels and to clean debris from the brail hooks. Live individuals were counted by area (e.g., north shore, south shore upstream of effluent pipe, south shore downstream of effluent pipe, and brail) and returned to the river upstream of the discharge channel. Voucher specimens of each species were retained and deposited in the INHS Mollusk Collection, Champaign, Illinois. Shell material was classified as live, dead (valves with tissue present or shiny nacre and intact periostracum), or relict (valves with chalky nacre and worn periostracum) based on condition of best specimen found.

EM 4

AT..

I- - -

FIGURE 2-1.

FISH SAMPLING LOCATIONS IN THE KANKAKEE RIVER NEAR BRAIDWOOD STATION fm

R-W.-

A AT ef-f;-

  • ftat1.c~tnA Vnoniae ln.,nctlnntinn TABLE 2-1.

FISH SAMPLING LOCATIONS IN THE KANKAKEE RIVER NEAR BRAIDWOOD NUCLEAR STATION LOCATION DESCRIPTION 1

Approximately 1000 m upstream of the Station's cooling pond make-up water intake structure. This sampling transect is not influenced by intake or discharge of cooling pond water.

2 Located in Horse Creek from its confluence with the Kankakee River to approximately 300 m upstream. Horse Creek represents a potential fish spawning area for Kankakee River fishes.

3 Located in the area of Braidwood Station's intake structure.

4 Located in the area of Braidwood Station's discharge structure. This area may be affected by discharges from the cooling pond.

5 Located approximately 300 m downstream form the discharge structure.

This site represents near-field recovery from possible impacts associated with discharge from the cooling pond.

6 Located approximately 1.6 km downstream from the discharge structure, this location represents far-field recovery from possible impacts associated with discharge from the cooling pond.

.6

Rrnldwn*t N.rlpar g#n*nn lR--idwnnn ANuclor SQtationn tt..itAVo-o nonn UPSTREAM BOUNDARY CURRENT DIRECTION 77 BOAT I.

THIRD RUN FIRST RUN SECOND RUN V

DOWNSTREAM BOUNDARY FIGURE 2-2.

ILLUSTRATION OF ELECTROFISHING BOAT PATH DURING SAMPLING IN THE BRAIDWOOD STATION MONITORING AREA HE

R*n;Aun*,l M.*lanr *tnt;,*n

  • tntD.fic#Dd.*nD*'iDe Invo*tiantinn Q-to-lictod Cnagiov Invactionifign FIGURE 2-3.

KANKAKEE RIVER AT THE BRAIDWOOD STATION DISCHARGE CHANNEL SOUTHERN EDGE RESTHAVEN. WILL COUNTY, ILLINOIS (41.252104, -88.133355). RED LINES (NINE LINES IN CHANNEL) INDICATE WHERE BRAILING OCCURRED AND YELLOW LINES (ALONG SHORE)

INDICATE WHERE HAND-PICKING OCCURRED (PHOTO TAKEN FROM GOOGLE EARTH ON 11 AUGUST 2008) im 8

D JA-,

A W..

1.

cf-f;-

C.-

1.1-1-1 J*-

7-fl.

aW UV LfllVU

.J W l&

UC(SU.,

a Al, rcjiriaiu.

3.0 RESULTS AND DISCUSSION Fish and freshwater mussel field surveys were conducted August 4 - 8, 2008. River conditions were typically low flow, clear water during the early part of the week when the fish surveys were completed and a rising river with less clarity near the end of the week when the mussel survey was completed.

3.1 FISH SURVEY 3.1.1 ELECTROFISHING A total of 1,308 fish comprised of 45 taxa (43 species) were collected by electrofishing at the six sampling locations (Table 3-1). Theseý collections were dominated by longear sunfish (26.5%), spotfin shiner (13.1%), bluntnose minnow (11.7%), rock bass (5.3%),

smallmouth bass (4.8%), and largemouth bass (4.8%).

In the two locations (3 and 4) that will be most affected by the project, a total of 31 taxa were collected, dominated by longear sunfish (31.1%), spotfin shiner (10.7%), rock bass (10.5%), sand shiner (9.2%), golden redhorse (6.5%), and smallmouth bass (6.5%). The species composition at these locations was similar to that of the entire study area.

Electrofishing was attempted in the channel portion of the river at: locations 3 and 4; but no fish were collected. It was deemed that the water was too deep and fish were moving ahead of the three phase AC field.

Two pallid shiners were collected by electrofishing, one at station 5L and one at station 5R. Both were taken approximately 300 m (- 975 ft) downstream from the discharge channel in an area described as the near-field recovery zone for the discharge and well over 200 m (- 650 ft) downstream from the immediate impact zone of the proposed project. Both specimens were taken in areas where a sand bar drops off quickly to deeper water.

One large river redhorse was collected approximately 1000 m (- 3250 ft) upstream from the discharge channel at Station 1L. This was the first river redhorse collected in the IM 9

R-W., ýA AT Qmf;-

Prni~~u~nnA 3 1 1n-lsnr--tistnn Qtto.,o Voies Inveslatiinn vicinity during the past five years. Redhorse spp collected were all young of year which are difficult to identify to species at this size. Based on adults collected during the past five years, it is doubtful that any of these young of year were river redhorse.

None of the three state-listed specimens were taken in the immediate proximity of the proposed project and will not pose a regulatory effect on the permitting process. Exelon may wish to apply for an incidental take permit as a precautionary measure because fish are motile and tend to occupy different areas under different flow conditions.

3.1.2 SEINING A total of 686 fish comprised of 22 taxa (20 species) were collected by seining at the six sampling locations (Table 3-2).

These collections were dominated by spotfin shiner (36.2%), bluntnose minnow (15.3%), striped shiner (11.7%), sand shiner (9.0%), and Johnny darter (8.3%). These five species composed 80.5% of the total collection. All percent composition information is approximate based on approximately 30 meters

(-I 00ft) of shoreline being sampled.

Collections in locations 3 and 4 yielded 61.2% of the total catch with 49.1% of the total catch being taken at station 4R, which is just downstream of the discharge channel.

Station 4R composed 86.7% of the total spotfin shiner catch, 58.8% of the striped shiner collection, 33.9% of the sand shiners taken, 26.7% of the bluntnose minnows harvested, but 0.0% of the Johnny darters collected. These contributions are likely the combination of attractive bottom habitat and Warmwater discharge from-the cooling lake.

No threatened or endangered species were collected during the seining phase of the survey.

3.1.3 WATER QUALITY Ancillary water quality data collected during the fish survey are presented in Appendix A.

10

D_14 A AT..

I-C# IJ--

00 (WWUJ c

ar n4iU aJIW~i&

35iLiIVLI 2ELL SIZ 11veusluI 3.2 MUSSEL SURVEY Six special-status species have been recorded from the Kankakee River in Illinois, one of which has been reported from near the Braidwood Station discharge channel (Table 3-3).

Included in the six are three state endangered species (Simpsonaias ambigua, Plethobasus cyphyus, and Epioblasma triquetra) and three state threatened species (Cyclonaias tuberculata, Elliptio dilatata, and Ligumia recta).

A summary of the historical occurrence of these six. species is given below. (The INHS report, as submitted, is provided in Appendix B.)

Simpsonaias ambigua, salamander mussel, has been recorded in Illinois from creeks as well as large rivers (Howard 1951; Cummings and Mayer 1997; Illinois Natural History Survey (INHS) Mollusk Collection). It appears to be restricted to spaces under bedrock ledges or large, flat rocks, or in cracks in bedrock in fast-flowing reaches. Moderately fresh shells (but no live specimens) have been collected from the Kankakee River as recently as 1991 (INHS Mollusk Collection). Existing records may not reflect the actual historical or present range of this species because, unless its microhabitat is searched specifically, S. ambigua is likely to be overlooked.

Plethobasus cyphyus, sheepnose, was formerly widespread in the medium-sized to large rivers of Illinois (Cummings and Mayer 1997; INHS Mollusk Collection). Currently this species is known in Illinois from small, isolated populations in the Wabash, Kankakee, and Mississippi rivers. Within the last 10 years, live individuals have been found in the Kankakee River at Wilmington (1984), Custer Park (1986), Kankakee (1988), and Aroma Park (2004) (INHS Mollusk Database).

Cyclonaias tuberculata, purple wartyback,_was historically widely distributed in Illinois, including the Kankakee River (Cummings and Mayer 1997; INHS Mollusk Collection).

Since 1980, it has been found alive in the Kankakee River at the IL Rte 53 bridge (1984),

Wilmington (1984), Kankakee River State Park (1994), US Hwy 45 bridge (1987),

Custer Park (2000), Langham Island (2000), Aroma Park (2004), and the 1-55 bridge (2008) (INHS Mollusk Database).

11

R-;J-I A7..

1-Ci-#;-

cf-#-

14*ý#-l F_.-#;__#:__

Elliptio dilatata, spike, was historically widely distributed in Illinois, including the Kankakee River (Cummings and Mayer 1997; INHS Mollusk Collection). Since 1980, it has been found alive in the Kankakee River at the US Hwy 45 bridge (1987), Custer Park (1988), Des Plaines Wildlife Conservation Area (1991), Momence (2000), and Aroma Park (2004) (INHS Mollusk Database).

Epioblasma triquetra, snuffbox, has been recorded in Illinois from creeks as well as large rivers (Cummings and Mayer 1997; INHS Mollusk Collection). Currently this species is known in Illinois from a small, isolated population in the Embarras River and hasn't been collected alive in the Kankakee River (INHS Mollusk Database).

Ligumia recta, black sandshell, was formerly widespread in the medium-sized to large rivers of Illinois, including the Kankakee River (Cummings and Mayer 1997; EINHS Mollusk Collection). Since 1980, it has been found alive in the Kankakee River at the US Hwy 45 bridge (1987) Wilmington (1999), Kankakee River State Park (1994), Custer Park (2000), Momence (2000), Langham Island (2000), Aroma Park (2004), and the 1-55 bridge (2008) (INHS Mollusk Database).

As with other areas of the Kankakee River, the area in the immediate vicinity of the Braidwood Station discharge channel supports a diverse and abundant fauna. A total of 212 live individuals from 15 species were collected alive during the survey conducted on August 8, 2008; included in this total were three live purple wartybacks (C. tuberculata),

which is state-threatened (Table 3-3). An additional eight species were collected as shell only, including fresh-dead Sheepnose (P. cyphyus), which is state-endangered, relict sipke (E. dilatata) and Black snashell (L. recta), both of which are state-threatened (Table 3-3). The majority of live individuals collected were found while brailing in the channel portion of the river (20 individuals from three species, including one purple wartyback or while hand-picking the south shore upstream of the effluent pipe (156 individuals from 15 species including two purple wartybacks. No individuals were found on the north shore, and only 36 individuals from five species were found on the south shore 12

R-W.- l~w AT-Qf,-H-t;*

141ý#_#

7-4-

downstream of the discharge channel. The fresh-dead sheepnose was found on the south shore upstream of the discharge channel while the relict spike and black sandshell were found on the south shore both upstream and downstream of the discharge channel.

Habitat (silted-sand with small patches of mud and gravel) at the south shore upstream of the discharge channel proved to be conducive for large mussel populations, while habitat at the north shore (mud and rip-rap) was not conducive for freshwater mussels. The habitat along the south shore downstream of the discharge channel (silted-sand with large fluctuations in water temperature) suggested that this area was mostly unsuitable for freshwater mussels. Because of depth issues (>2 in), habitat in the center channel could not be assessed, but mussels were encountered in river channel areas upstream of the Braidwood Station discharge channel.

Collection of three live purple wartyback specimens (state-threatened) near the south shore and in the center channel upstream of the discharge channel indicates that the habitat in the area proposed for the diffuser supports this species. Collection of one fresh-dead sheepnose shell (state-endangered) does not make the case for presence of live sheepnose in the immediate vicinity for two reasons. First, it is extremely difficult to determine when the animal died. Second, it is not possible to determine where the animal died. This portion of the Kankakee River experienced two major floods within the seven months prior to this survey. It is very possible that this shell may have been deposited in this area during the flooding that occurred during June 2008.

Based on the findings-of the freshwater mussel survey, Exelon needs to initiate discussions with Illinois DNR focusing on application for an incidental take permit for purple wartyback during the construction phase of the project and to define the agency's position regarding the fresh-dead sheepnose mussel.

13

D-418..

18 AT..

I--

C CtntoJctol VO,.;OC ~M.WC6~nhnn 00 c

r n

TABLE 3-1 FISH CAPTURED BY ELECTROFISHING IN THE KANKAKEE RIVER AND HORSE CREEK Braidwood Station - August 4, 2008 TAXON 1La 1Ra 2

3Lb 3R" 4Lb 4R 5La 5Ra 6La 6Ra Totalc Longnose gar 2

5 2

1 10 0.8 Gizzard shad 1

1 2

1 2

2 9

0.7 Grass pickerel 1

1 1

3 0.2 Carp 9

3 12 0.9 Hornyhead chub 2

1 3

0.2 Golden shiner 1

1 0.1 Redfin shiner 1

1 1

3 0.2 Pallid shiner 1

1 2

0.2 Ghost shiner 2

2 0.2 Striped shiner 1

4 1

3 2

11 0.8 Rosyface shiner 1

1 0.1 Mimic shiner 1

1 2

0.2 Spotfin shiner 12 18 9

4 30 19 31 33 16 172 13.1 Sand shiner 2

1 2

31 6

12 2

2 58 4.4 Bluntnose minnow 8

1 24 4

8 12 43 24 20 9

153 11.7 Bullhead minnow 3

4 9

1 25 9

1 4

56 4.3 Creek chub 3

1 4

0.3 Carpsucker spp.

4 4

0.3 River carpsucker 1

2 1

4 0.3 Quillback 1

1 0.1 Bigmouth buffalo 1

1 0.1 Northern hog sucker 1

1 0.1 Spotted sucker 2

3 5

0.4 Redhorse spp.

1 22 1

24 1.8 Silver redhorse 2

2 1

5 0.4 River redhorse I

1 0.1 Golden redhorse 1

2 1

11 3

11 14 9

5 2

59 4.5 Shorthead redhorse 1

1 0.1 Channel catfish 2

1 1

5 9

0.7 14

.,i Rrmidwnnd Aharlonr.Vt~nt Braidwood Nuclear Vit-fi-n TABLE 3-1 (Continued)

FISH CAPTURED BY ELECTROFISHING IN THE KANKAKEE RIVER AND HORSE CREEK Braidwood Station - August 4, 2008 TAXON 1La 1Ra 2b 3Lb 31b 4Lb 4RO 5La 5Ra 6La 6Ra TOTALC Brook silverside 3

14 17 1.3 Rockbass 3-5 4

5 13 18 6

1 5

5 4

69 5.3 Green sunfish I

1 0.1 Pumpkinseed 1

1 2

0.2 Orangespotted sunfish 3

3 6

10 1

3 1

27 2.1 Bluegill 1 '

6 2

3 6

11 5

10 3

47 3.6 Longear sunfish 40 52 29 29

.22 53 21 24 26 27 23 346 26.5 Smallmouth bass 3

4 4

7 7

4 8

12 5

6 3

63 4.8 Largemouth bass 3

3 1

1 1

48 2

1 3

63 4.8 Black crappie

4.

1 1

2 8

0.6 Johnny darter

1 1

12 1

3 4

1 5

28 2.1 Logperch 2

2 3

7 0.5 Blackside darter 1

1 1

1 7

0.5 Slenderhead darter

,o2 1

3 0.2 Banded darter 1 1 1

2 0.2 Freshwater drum 1

1 0.1 Total fish 92 72 148 60 82 161 99 227 153 129 85 1308 Total Taxa 18 12 20 14 15 19 12 21 24

.14 20 45 CPE (fish/hr) 184.0-144.0 592.0, 240.0 328.0 644.0 396.0 454.0 306.0 258.0 170.0 307.8 a Based on 0.50 hrs effort b Based on 0.25 hrs effort Based on 4.25 hrs effort 15

R-W.,

.4 AT..

1-J State-listed Q-ies Investiantion TABLE 3-2 FISH CAPTURED BY MINNOW SEINE IN THE KANKAKEE RIVER AND HORSE CREEK Braidwood Station - August 5, 2008 TAXON IL IR 2

3L 3R 4L 4R 5L 5R 6L 6R TOTAI Grass pickerel 1

1 2

0.3 Golden shiner Hornyhead chub Striped shiner Rosyface shiner Mimic shiner Spotfin shiner Sand shiner Bluntnose minnow Bullhead minnow Creek chub Carpsucker spp.

Redhorse spp.

2 20 3

47 7

1 1

2 4

7 1

10 6

3 3

5 21 4

4 15 2

215 9

21 25 3

28 29 1

23 3

1 1

4 2

21 1

165 2

2 5

5 1

3 80 4

8 248 62 105 35 6

1 9

4 13 7

1 2

1 9

3 15 2

57 8

0.1 0.4 11.7 0.6 1.2 36.2 9.0 15.3 5.1 0.9 0.1 1.3 0.6 1.9 1.0 0.1 0.3 0.1 0.7 0.4 2.2 0.3 8.3 1.2 Blackstripe topminnow Brook silverside 8

2 7

Sunfish spp.

Rock bass Orangespotted sunfish Bluegill Longear sunfish Smallmouth bass Largemouth bass Black crappie Johnny darter Blackside darter Slenderhead darter Total Fish Total Taxa I

11 1

I 2

1 1

4 1

1 1

3 8

1 I

2 9

9 22 6

55 9

1 9

16 1

1 0

0 45 9

30 4

8 5

337 13 123 15 50 12 18 8

11 6

686 22 16

Rrns'dwlnn ANurlenr Q#nti~nn

  • tnt*_l;etDrl *nD*;D*

lnu*et;*nt;nn R-W-ood Nwi-Q-ti-n Cf-0. 1,W.A Q.

Table 3-3 Freshwater mussel (Bivalvia: Unionidae) known from the Kankakee River, Will County, Illinois Also included are those species found as incidental encounters during fish surveys (data marked with an "X" and are from INHS Mollusk Collection, Champaign). "L" are number of individuals found alive, "D" are those collected only a fresh-dead shell, and "R" are those discovered only as relict shell. Special status includes ST = state-threatened and SE = state-endangered.

Subfamily Anodontinae Ambleminae Lampsilinae Scientific name Alasmidonta marginata Lasmigona complanata Lasmigona costata Pyganodon grandis Simpsonaias ambigua SE Strophitus undulatus Utterbackia imbecillis Amblema plicata Cyclonaias tuberculata ST Elliptio dilatata ST Fusconaiaflava Megalonaias nervosa Plethobasus cyphyus SE Pleurobema sintoxia Quadrula metanevra Quadrula pustulosa Quadrula quadrula Actinonaias ligamentina Epioblasma triquetra SE Lampsilis cardium Lampsilis siliquoidea Leptodea fragilis Ligumia recta ST Potamilus alatus Potamilus ohiensis Toxolasma parvus Venustaconcha ellipsiformis Villosa iris SE Common name Elktoe White heelsplitter Flutedshell Giant floater Salamander mussel Creeper Paper pondshell Threeridge Purple wartyback Spike Wabash pigtoe Washboard Sheepnose Round pigtoe Monkeyface Pimpleback Mapleleaf Mucket Snuffbox Plain pocketbook Fatmucket Fragile papershell Black sandshell Pink heelsplitter Pink papershell Lilliput Ellipse Incidental take X

X X

X X

X X

2008 survey D

1OL 13 L 3L R

7L 28 L 3L R

D D

D 5L 2L 12L 2L 115 L 3L 5L 3L R

D IL X

X Rainbow FM 17

4 AT..

I_

C C.-

U-4 J*__ 7-4__

4.0

SUMMARY

Exelon Generation Company is proposing to place a warmwater diffuser pipe in/on the bottom of the Kankakee River near the existing warmwater discharge channel on the south shoreline of the river near the Braidwood Nuclear Station.

Fisheries have been monitored in this vicinity since 1977 and the monitoring program has collected both pallid shiner (state-endangered) and river redhorse (state-threatened) in this area on certain occasions over the 30-year program.

Freshwater mussels have been surveyed several times in nearby reaches of the Kankakee River during the 2 0 th century, but never in the proposed project area. Several state-listed mussel species were collected during these surveys.

HDR Engineering (HDR) was retained to conduct fish and freshwater mussel survey in the vicinity of the proposed diffuser pipe location to determine presence/absence of state-listed fish and mussel species in this area.

HDR and its predecessor LMS has been conducting the fish monitoring program since 1995 and has the 30+ year historical data base on file. HDR subcontracted the freshwater mussel survey to Illinois Natural History Survey, the recognized experts on freshwater mussels in the state.

Both the fisheries and the mussel surveys were conducted during the period August 4-8, 2008. Two pallid shiners (state-endangered) were collected approximately 300 m downstream of the discharge channel (over 600 ft downstream of the proposed diffuser pipe site) and one river redhorse (state-threatened) was taken approximately 1000 m upstream of the diffuser channel (over 3000 ft upstream of the proposed diffuser pipe site).

Three live specimens of the mussel purple wartyback were collected within 100 ft upstream of the discharge channel (two near shore and one in the central river channel).

One fresh-dead sheepnose shell (state-endangered) was collected near the south shoreline 18

Braidwood Nuclear Station State-listed Species Investization within 100 ft upstream of the discharge channel and relic shells of spike and black sandshell (both state-threatened) were collected both upstream and downstream of the discharge channel along the south shoreline of the river.

HDR recommends that Exelon enter into discussions with the Illinois DNR regarding application for the incidental taking of pallid shiner, river redhorse, purple wartyback, and possibly sheepnose during the construction phase of the proposed project. The fish species, in particular, are motile and may occupy different areas of the river under different flow conditions and at different times of the year.

19

R-1.4.1 11 All, 1ý ý ef-f;-

V~ntoJictaA Cnnnio~. ~nrncflcnflnn

5.0 REFERENCES

Cummings, K.S., and C.A. Mayer. 1997. Distributional checklist and status of Illinois freshwater mussels (Mollusca: Unionacea).

pp. 129-145 in K.S. Cummings, A.C.

Buchanan, C.A. Mayer, and T.J. Naimo, eds.

Conservation and management of freshwater mussels II: Initiatives for *the future.

Proceedings of a UMRCC Symposium, 16-18 October 1995, St. Louis Missouri.

Upper Mississippi River Conservation Committee, Rock Island, Illinois. 293 pp.

HDR/LMS.

2008. Braidwood Station Kankakee River fish monitoring program, 2007.

Annual report submitted to Exelon Nuclear February 2008.

Howard, A.D.

1951.

A river mussel parasitic on a salamander.

Natural History Miscellanea 77:1-6.

Illinois Endangered Species Protection Board.

2005.

Checklist of endangered and threatened animals and plants of Illinois. Illinois Endangered Species Protection Board, Springfield.

Kramer, K. USF&WS. pers. comm. August 20, 2008.

Page, L.M., K.S. Cummings, C.A. Mayer, S.L. Post, and M.E. Retzer.

1992.

Biologically significant streams. An evaluation of the streams of Illinois based on aquatic biodiversity.

Illinois Natural History Survey, Center for Biodiversity, Technical Report. 1992(1):vi + 485 pp.

Strayer, D.L. and D.R. Smith. 2003. A Guide to Sampling Freshwater Mussel Populations. American Fisheries Society, Monograph 8, Bethesda, Maryland. 103 p.

Suloway, L. 1981. The unionid (Mollusca: Bivalvia) fauna of the Kankakee River in Illinois. American Midland Naturalist 105(2):233-239.

Tiemann, J.S., K.S. Cummings, and C.A. Mayer. 2007. Updates to the distributional checklist and status of Illinois freshwater mussels (Mollusca:

Unionacea).

Transactions of the Illinois State Academy of Science 100:107-123.

Turgeon, D.D., J.F. Quinn, Jr., A.E. Bogan, E.V. Coan, F.G. Hochberg, W.G. Lyons, P.M. Mikkelsen, R.J. Neves, C.F.E. Roper, G. Rosenberg, B. Roth, A. Scheltema, F.G. Thompson, M. Vecchione, and J.D. Williams. 1998. Common and scientific names of aquatic invertebrates from the United States and Canada: Mollusks. 2nd Edition. American Fisheries Society, Special Publication 26:ix-526.

Wilson, C.B., and H.W. Clark. 1912. The mussel fauna of the Kankakee basin. Report and Special Papers of the U.S. Fish Commission. [Issued separately as U.S. Bureau of Fisheries Document 758]. 1911:1-52 + I map.

20

APPENDIX A ANCILLARY WATER QUALITY DATA COLLECTED DURING FISHERIES SURVEY A-1

TABLE A-1.

ANCILLARY MEASUREMENTS RECORDED CONCURRENTLY WITH ELECTROFISHING SAMPLES FROM THE KANKAKEE RIVER AND HORSE CREEK Braidwood Nuclear Station - August 4, 2008 IL IR 2

3L 3R 4L 4R 5L 5R 6L 6R PARAMETER Time 1355 1310 1445 1535 0745 1630 0655 1135 1030 0835 0940 Temperature (°C) 26.9 26.9 27.6 27.5 27.2 28.5 29.1 27.2 27.8 27.2 27.4 Dissolved oxygen (ppm) 8.76 8.20 10.96 11.12 11.47 12.09 10.06 9.96 10.17 11.3 11.30 pH 8.1 8.2 8.4 8.3 8.4 8.6 8.7 8.3 8.4 8.3 8.3 Conductivity (Vmhos/cm) 620 612 625 615 607 624 747 597 690 633 624 A-2

TABLE A-2.

ANCILLARY MEASUREMENTS RECORDED CONCURRENTLY WITH SEINING SAMPLES FROM THE KANKAKEE RIVER AND HORSE CREEK Braidwood Nuclear Station - August 5, 2008 IL IR 2

3L 3R 4L 4R 5L 5R 6L 6R PARAMETER Time 1310 1250 1215 1120 1020 1040 1000 0855 0835 0730 0750 Temperature (CC) 27.0 26.6 25.2 26.6 26.5 26.6 28.9 26.3 27.3 25.9 26.6 Dissolved oxygen (ppm) 10.20 8272 7.41 10.25 10.10 9.80 8.60 9.70 9.06 9.55 9.83 pH 8.3 8.2 8.0 8.4 8.4 8.5 8.7 8.4 8.4 8.3 8.3 Conductivity (jimhos/cm) 566 565 562 573 563 564 784 569 672 609 606 A-3

APPENDIX B FRESHWATER MUSSEL SURVEY REPORT SUBMITTED BY ILLINOIS NATURAL HISTORY SURVEY B-1

ILLINOIS. NATURAL HISTORY SURVEY MEMORANDUM TO:

Bruce Lippincott HDR Engineering, Inc. (HDR) 10207 Lucas Road Woodstock, IL 60098 FROM:

Jeremy S. Tiemann, Field Biologist Illinois Natural History Survey (INHS) 1816 South Oak Street Champaign, IL 61820 DATE:

11 August 2008

SUBJECT:

Freshwater mussel survey of the Kankakee River near the Braidwood Nuclear Station blowdown discharge channel INTRODUCTION This memorandum is submitted in response to a request by Bruce Lippincott (HDR) to Jeremy Tiemann (INHS) dated 30 June 2008 for a freshwater mussel survey to be conducted in the area of the Braidwood Nuclear Station blowdown discharge channel (herein, Braidwood Station discharge channel) in the Kankakee River, Will County, Illinois. Exelon Generation proposes to engineer and design a blowdown pipe discharge to be installed in the open channel line of the Kankakee River. This memorandum summarizes the results of the freshwater mussel survey conducted on 8 August 2008. Nomenclature used for freshwater mussels discussed in this memorandum follows Turgeon et al. (1998), and also includes changes discovered since its date of publication, original spelling, or priority of names. The current statuses of threatened and endangered species discussed in this memorandum are taken from Illinois Endangered Species Protection Board (IESPB) (2005).

The objectives of this survey were to determine presence/absence of state-listed freshwater mussel species and describe the freshwater mussel assemblages and their densities, particularly those of special status, in the reach of the Kankakee River from B-2

approximately 100-ft upstream of the Braidwood Station discharge channel to approximately 200-ft downstream of this location. Freshwater mussels were collected by both timed searches and area searches (Strayer and Smith 2003). Data should be sufficient to make decisions regarding incidental take permit application or more extensive mitigation approaches.

PROJECT LOCATION Sampling for freshwater mussels was conducted in the immediate vicinity of the Kankakee River at the Braidwood Station discharge channel, southern edge Resthaven. Will County, Illinois (41.252104, -88.133355) (Figure 1).

B-3

Figure 1. Kankakee River at the Braidwood Station discharge channel southern edge Resthaven. Will County, Illinois (41.252104, -88.133355). Red lines (nine lines in channel) indicate where brailing occurred and yellow lines (along shore) indicate where hand-picking occurred. Photo taken from Google Earth on 11 August 2008.

B-4

BACKGROUND The Kankakee River supports some of Illinois' most diverse and abundant mussel populations with 27 extant and 40 historical species (Cummings and Mayer 1997; Tiemann et al. 2007). It has been surveyed several times for mussels in this century including: 1909 (Wilson and Clark 1912); 1956 and 1960 (M.R. Matteson unpublished; INHS Mollusk Collection); and 1978 (Suloway 1981). Page et al. (1992) regard the mussel populations of the Kankakee River to be of national importance.

The unionid mussel fauna in the Kankakee River at the Braidwood Station discharge channel had not been examined by a formal freshwater mussel survey until the present study; however, incidental encounters had been picked up while conducting fish surveys in the area, including one state listed species (Table 1). The Kankakee River here at the Braidwood Station discharge channel is free flowing and offers a wide variety of habitats for freshwater mussels to colonize.

Threatened and Endangered Mussels in the Kankakee River Six special-status species have been recorded from the Kankakee River in Illinois, one of which has been reported from near the Braidwood Station discharge channel (Table 1).

Included in the six are three state endangered species (Simpsonaias ambigua, Plethobasus cyphyus, and Epioblasma triquetra) and three state threatened species (Cyclonaias tuberculata, Elliptio dilatata, and Ligumia recta).

A summary of the historical occurrence of these six species is given below.

Simpsonaias ambigua, salamander mussel, has been recorded in Illinois from creeks as well as large rivers (Howard 1951; Cummings and Mayer 1997; INHS Mollusk Collection). It appears to be restricted to spaces under bedrock ledges or large, flat rocks, or in cracks in bedrock in fast-flowing reaches. Moderately fresh shells (but no live specimens) have 'been collected from the Kankakee River as recently as 1991 (INHS Mollusk Collection). Existing records may not reflect the actual historical or present range of this species because, unless its microhabitat is searched specifically, S. ambigua, is likely to be overlooked.

Plethobasus cyphyus, sheepnose, was formerly widespread in the medium-sized to large rivers of Illinois (Cummings and Mayer 1997; INHS Mollusk Collection). Currently this species is known in Illinois from small, isolated populations in the Wabash, Kankakee, and Mississippi rivers. Within the last 10 years, live individuals have been found in the Kankakee River at Wilmington (1984), Custer Park (1986), Kankakee (1988), and Aroma Park (2004) (INHS Mollusk Database).

Cyclonaias tuberculata, purple wartyback, was historically widely distributed in Illinois, including the Kankakee River (Cummings and Mayer 1997; INHS Mollusk Collection).

Since 1980, it has been found alive in the Kankakee River at the IL Rte 53 bridge (1984),

Wilmington (1984), Kankakee River State Park (1994), US Hwy 45 bridge (1987),

B-5

Custer Park (2000), Langham Island (2000), Aroma Park (2004), and the 1-55 bridge (2008) (INHS Mollusk Database).

Elliptio dilatata, spike, was historically widely distributed in Illinois, including the Kankakee River (Cummings and Mayer 1997; INHS Mollusk Collection). Since 1980, it has been found alive in the Kankakee River at the US Hwy 45 bridge (1987), Custer Park (1988), Des Plaines Wildlife Conservation Area (1991), Momence (2000), and Aroma Park (2004) (INHS Mollusk Database).

Epioblasma triquetra, snuffbox, has been recorded in Illinois from creeks as well as large rivers (Cummings and Mayer 1997; INHS Mollusk Collection). Currently this species is known in Illinois from a small, isolated population in the Embarras River and hasn't been collected alive in the Kankakee River (INHS Mollusk Database).

Ligumia recta, black sandshell, was formerly widespread in the medium-sized to large rivers of Illinois, including the Kankakee River (Cummings and Mayer 1997; INHS Mollusk Collection). Since 1980, it has been found alive in the Kankakee River at the US Hwy 45 bridge (1987) Wilmington (1999), Kankakee River State Park (1994), Custer Park (2000), Momence (2000), Langham Island (2000), Aroma Park (2004), and the 1-55 bridge (2008) (INHS Mollusk Database).

METHODS The Kankakee River at the Braidwood Station discharge channel was investigated for the presence of freshwater mussels on 8 August 2008. Field crew consisted of ENHS personnel J.S. Tiemann, K.S. Cummings, C.A. Mayer, C.A. Phillips, A.R. Kuhns, J.L. Sherwood, and D.M. Ellington, as well as Chicago Academy of Science staff S. Clark. Sampling consisted of two phases (Strayer and Smith 2003). Phase I was handing picking along shoreline (yellow area in Figure 1) by six people for 2.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, which is equivalent to 15 person-hours total. During the time search, live individuals and valves of dead specimens were collected in a random manner, covering all substrate types. Phase 2 consisted of nine 220-m brail runs in the center of the river (red lines in Figure 1); the brail was retrieved several times throughout the length a run to check for mussels and to clean debris from the hooks. Live individuals were counted by area (e.g., north shore, south shore upstream of effluent pipe, south shore downstream of effluent pipe, and brail) and returned to the river upstream of the effluent pipe. Voucher specimens of each species were retained and deposited in the MNHS Mollusk Collection, Champaign. Shell material will be classified as live, dead (valves with tissue present or shiny nacre and intact periostracum), or relict (valves with chalky nacre and worn periostracum) based on condition of best specimen found.

RESULTS AND DISCUSSION As with other areas of the Kankakee River, the area in the immediate vicinity of the Braidwood Station discharge channel supports a diverse and abundant fauna. A total of B-6

212 live individuals from 15 species were collected alive during the 2008 survey; included in this total were three live C. tuberculata, which is state-threatened (Table 1).

An additional eight species were collected as shell only, including fresh-dead P. cyphyus which is state-endangered, relict E. dilatata and L. rectaboth of which are state-threatened (Table 1). The majority of live individuals collected were found while brailing (20 individuals from three species, including one C. tuberculata) or while hand-picking the south shore upstream of the effluent pipe (156 individuals from 15 species including two C. tuberculata). No individuals were found on the north shore, and only 36 individuals from five species were found on the south shore downstream of the effluent pipe). The fresh-dead P. cyphyus was found on the south shore both upstream of the effluent pipe while the relict E. dilatata and L. recta were found on the south shore both upstream and downstream of the effluent pipe.

Habitat (silted-sand with small patches of mud and gravel) at the south shore upstream of the effluent pipe proved to be conducive for large mussel populations, while habitat at the north shore (mud and rip-rap) and south shore downstream of the effluent pipe (silted-sand with large fluctuations in water temperature) suggested that this area was mostly unsuitable for freshwater mussels. Because of depth issues (>2 m), habitat in the center channel could not be assessed, but mussels were encountered in areas upstream of the Braidwood Station discharge channel.

B-7

Table 1. Freshwater mussel (Bivalvia: Unionidae) known form the Kankakee River, Will County, Illinois. Also included are those species found as incidental encounters during fish surveys (data marked with an "X" and are from INHS Mollusk Collection, Champaign) and those collected during the 2008 freshwater mussel survey of the Braidwood Station discharge channel. "L" are number of individuals found alive, "D" are those collected only a fresh-dead shell, and "R" are those discovered only as relict shell. Special status includes ST = state-threatened and SE = state-endangered.

Subfamily Scientific name Common name Incidental 2008 take survey Anodontinae Alasmidonta marginata Lasmigona complanata Ambleminae Lampsilinae Lasmigona costata Pyganodon grandis Simpsonaias ambigua SE Strophitus undulatus Utterbackia imbecillis Amblema plicata Cyclonaias tuberculata ST Elliptio dilatata ST Fusconaiaflava Megalonaias nervosa Plethobasus cyphyus SE Pleurobema sintoxia Quadrula metanevra Quadrula pustulosa Quadrula quadrula Actinonaias ligamentina Epioblasma triquetra SE Lampsilis cardium Lampsilis siliquoidea Leptodea fragilis Ligumia rectaST Potamilus alatus-Potamilus ohiensis Toxolasma parvus Venustaconcha ellipsiformis Villosa iris SE Elktoe-White heelsplitter Flutedshell Giant floater Salamander mussel Creeper Paper pondshell Threeridge Purple wartyback Spike Wabash pigtoe Washboard Sheepnose Round pigtoe Monkeyface Pimpleback Mapleleaf Mucket Snuffbox Plain pocketbook Fatmucket Fragile papershell Black sandshell Pink heelsplitter Pink papershell Lilliput Ellipse X

X X

X X-X 13L 3L R

7L 28 L 3L R

D D

D 5L 2L 12L 2L 115L 3L 5L 3L R

D X

D 1OL X

X 1L Rainbow

  • B-8

LITERATURE CITED Cummings, K.S., and C.A. Mayer. 1997. Distributional checklist and status of Illinois freshwater mussels (Mollusca: Unionacea). pp. 129-145 in K.S. Cummings, A.C.

Buchanan, C.A. Mayer, and T.J. Naimo, eds. Conservation and management of freshwater mussels II: Initiatives for the future. Proceedings of a UMRCC Symposium, 16-18 October 1995, St. Louis Missouri. Upper Mississippi River Conservation Committee, Rock Island, Illinois. 293 pp.

Howard, A.D. 1951. A river mussel parasitic on a salamander. Natural History Miscellanea 77:1-6.

Illinois Endangered Species Protection Board. 2005. Checklist of endangered and threatened animals and plants of Illinois. Illinois Endangered Species Protection Board, Springfield.

Page, L.M., K.S. Cummings, C.A. Mayer, S.L. Post, and M.E. Retzer. 1992.

Biologically significant streams. An evaluation 'of the streams of Illinois based on aquatic biodiversity. Illinois Natural History Survey, Center for Biodiversity, Technical Report. 1992(l):vi + 485 pp.

Strayer, D.L. and D.R. Smith. 2003. A Guide to Sampling Freshwater Mussel Populations. American Fisheries Society, Monograph 8, Bethesda, Maryland. 103 p.

Suloway, L. 1981. The unionid (Mollusca: Bivalvia) fauna of the Kankakee River in Illinois. American Midland Naturalist 105(2):233-239.

Tiemann, J.S., K.S. Cummings, and C.A. Mayer. 2007. Updates to the distributional checklist and status of Illinois freshwater mussels (Mollusca: Unionacea).

Transactions of the Illinois State Academy of Science 100:107-123.

Turgeon, D.D., J.F. Quinn, Jr., A.E. Bogan, E.V. Coan, F.G. Hochberg, W.G. Lyons, P.M. Mikkelsen, R.J. Neves, C.F.E. Roper, G. Rosenberg, B. Roth, A. Scheltema, F.G. Thompson, M. Vecchione, and J.D. Williams. 1998. Common and scientific names of aquatic invertebrates from the United States and Canada: Mollusks. 2nd Edition. American Fisheries Society, Special Publication 26:ix-526.

Wilson, C.B., and H.W. Clark. 1912. The mussel fauna of the Kankakee basin. Report and Special Papers of the U.S. Fish Commission. [Issued separately as U.S. Bureau of Fisheries Document 758]. 1911:1-52 + 1 map.

B-9