ML13331A792

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-13,allowing Operation Until 851130 Refueling Outage for Steam Generator Insp.Rev Based on Conclusions of 850319 1985 Reevaluation of Steam Generator Interval,Mar 1985
ML13331A792
Person / Time
Site: San Onofre 
Issue date: 04/09/1985
From: Baskin K, Holcombe J
SAN DIEGO GAS & ELECTRIC CO., SOUTHERN CALIFORNIA EDISON CO.
To:
Shared Package
ML13331A791 List:
References
NUDOCS 8504110320
Download: ML13331A792 (6)


Text

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION Application of SOUTHERN CALIFORNIA EDISON

)

COMPANY and SAN DIEGO GAS & ELECTRIC COMPANY )

for a Class 104(b) License to Acquire,

)

DOCKET NO. 50-206 Possess, and Use a Utilization Facility as

)

Part of Unit No. 1 of the San Onofre Nuclear )Amendment Application No. 128 Generating Station

)

SOUTHERN CALIFORNIA EDISON COMPANY and SAN DIEGO GAS & ELECTRIC COMPANY, pursuant to 10 CFR 50.90, hereby submit Amendment No. 128.

This amendment consists of Proposed Change No. 150 to Provisional Operating License No. DPR-13.

Proposed Change No. 150 revises Provisional Operating License No. DPR-13, Section 3, "Contents and Conditions."

Provisional Operating License No. DPR-13, Section 3, "Contents and Conditions," Condition 3.E, "Steam Generator Inspection," currently requires an interim steam generator inspection 6 equivalent full power months of operation from the backfitting outage that ended on November 27, 1984.

Implementation of the current Condition 3.E would require 3-4 week inspection outage, currently scheduled to begin on May 3, 1985.

Proposed Change No. 150 is a request to revise Condition 3.E, "Steam Generator Inspections," to allow operation until the scheduled November 30, 1985 refueling outage when a steam generator inspect-ion will be performed. This revision is based upon the conclusions of the report entitled "1985 Re-evaluation of Steam Generator Inspection Interval, March 1985", provided by SCE's letter dated March 19, 1985.

9504110320 850409 PDR ADOCK 05000206 P

PDR

-2 In the event of conflict, the information in Amendment Application No. 128 supersedes the information previously submitted.

Based on the safety analysis provided in the Description of Proposed Change and Safety Analysis, it is concluded that (1) this proposed change does not involve an unreviewed safety question as defined in 10 CFR 50.59, nor does it present significant hazards considerations not described or implicit in the Final Safety Analysis, and (2) there is reasonable assurance that the health and safety of the public will not be endangered by the proposed change.

Pursuant to 10 CFR 170.12, as revised in 49 FR 21293 dated May 21, 1984, the review of the Proposed Change contained in Amendment Application No. 128 has been determined to require a fee of $150.00. The fee of $150.00 was previously remitted with SCE's letter dated March 19, 1985.

-3 Subscribed on this

§ day of

___4____/_/__

Respectfully submitted, SOUTHERN CALIFORNIA EDISON COMPANY By Z

/rJ&

Kenneth P. Baskin Vice President Subsc!Lbed and swornoo before me this

~~ day of_____

OFFICIAL SEAL AGNES CRABTREE NOTARY PUBLIC -

CALIrORNI4 PRINCIPAL OFFICL ;N LOS ANGELES COUNTY My Commission Expires Aug. 27, 1986 Nota ublic in and for the County of Los A eles, State of California Charles R. Kocher James A. Beoletto Attorneys for Southern California Edison Company By James Beol-e to

-4 Subscribed on this 'FtW day of

,44 Respectfully submitted, SAN DIEGO GAS & ELECTRIC COMPANY J. C. Holcombe Vice President Subscribed and sworn to before me this day of OFrICIAL SEAL LORA INE E. GRAY N OTARY PU 2 - CALIFORNIA y Cm m:ss i On Exp. A, il 6, 1985 Na y Public In and for eC nty of San Diego, State of Californi David R. Pigott Samuel B. Casey

-Orrick, Herrington & Sutcliffe Attorneys for San Diego Gas & Electric Company ByDvd.Pot David R. Pigott

-2 J. Rengel Atomic Power Division Westinghouse Electric Corporation Box 355 Pittsburgh, Pennsylvania 15230 A. I. Gaede 23222 Cheswald Laguna Nigel, California 92677 Frederick E. John, Executive Director California Public Utilities Commission 5050 State Building San Francisco, California 94102 Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555 James.eorlnads\\

Assis t t Counsel Souther California Edison Company

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of SOUTHERN

)

CALIFORNIA EDISON COMPANY

)

and SAN DIEGO GAS & ELECTRIC

)

Docket No. 50-206 COMPANY (San Onofre Nuclear

)

Generating Station Unit No. 1 CERTIFICATE OF SERVICE I hereby certify that a copy of Amendment No. 128 was served on the following by deposit in the United States Mail, postage prepaid, on the 9th day of April 1985.

Henry 3. McGurren, Esq.

Staff Counsel U.S. Nuclear Regulatory Commission Washington, D.C.

20545 David R. Pigott, Esq.

Samuel B. Casey, Esq.

Orrick, Herrington & Sutcliffe 600 Montgomery Street San Francisco, California 94111 John V. Morowski Bechtel Power Corporation P.O. Box 60860, Terminal Annex Los Angeles, California 90060 Michael L. Mellor, Esq.

Thelen, Marrin, Johnson & Bridges Two Embarcadero Center San Francisco, California 94111 Huey Johnson Secretary for Resources State of California 1416 Ninth Street Sacramento, California 95814 Janice E. Kerr, General Counsel California Public Utilities Commission 5066 State Building San Francisco, California 94102