Amend Application 185 to License DPR-13,consisting of Proposed Change 227,revising Auxiliary Feedwater Sys Min Flow Requirements to Minimize Probability of Water Hammer & Damage to Steam Generators & Feedwater Piping
ML13331A453
Person / Time
Site: San Onofre 
Issue date: 07/03/1990
From: Ray H
Southern California Edison Co
To:
Shared Package
ML13331A452 List:
References
NUDOCS 9007060201
Download: ML13331A453 (5)


Text

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION Application of SOUTHERN CALIFORNIA EDISON COMPANY and SAN DIEGO GAS & ELECTRIC COMPANY DOCKET NO. 50-206 for a Class 104(b) License to Acquire, Possess, and Use a Utilization Facility as Amendment No. 185 Part of Unit No. 1 of the San Onofre Nuclear Generating Station SOUTHERN CALIFORNIA EDISON COMPANY and SAN DIEGO GAS & ELECTRIC COMPANY, pursuant to 10 CFR 50.90, hereby submit Amendment Application No. 185.

This amendment consists of Proposed Change No. 227 to Provisional Operating License No. DPR-13. Proposed Change No. 227 modifies the Technical Specifications incorporated in Provisional Operating License No. DPR-13 as Appendix A.

Proposed Change No. 227 is a request to revise the Auxiliary Feedwater System minimum flow requirements identified in Technical Specification 3.4.3. The auxiliary feedwater flow venturis will be replaced with new venturis to limit auxiliary feedwater flow to less than 150 gpm per steam generator under all post-trip or post-accident conditions. This will minimize the probability of a water hammer and subsequent damage to the steam generators and feedwater lines. As a result of the venturi replacement the auxiliary feedwater system minimum flow requirements will be reduced. This proposed change also requests an exemption from the technical specifications to allow a flow verification test of the steam driven auxiliary feedwater pump in MODE 1.

900706'0201 90)070:,3 PDR ADOCK (05000206 P

PDC

I-2 In the event of conflict, the information in Amendment Application No. 185 supersedes the information previously submitted.

Based on the significant hazards analysis provided in the Description of Proposed Change and Significant Hazards Consideration Analysis of Proposed Change No. 227, it is concluded that (1) the proposed change does not involve a significant hazards consideration as defined in 10 CFR 50.92, and (2) there is reasonable assurance that the health and safety of the public will not be endangered by the proposed change.

Subscribed on this __)_

day of

, 1990.

Respectfully submitted, SOUTHERN CALIFORNIA EDISON COMPANY By:

Hay/old B. Ray Senior Vice Presige Subsc ibed and sworn t before me this 3

day of

/9A Notary Public in and for the State of California NOTARY PUBLIC STATE OF CALIFORNIA County of Orange CONNIE R. MESSINA My Cohmission Exp. 5/13/94 James A. Beoletto Attorney for Southern California Edison Company By:

  • al g~et

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of SOUTHERN CALIFORNIA

)

EDISON COMPANY and SAN DIEGO GAS &

)

Docket No. 50-206 ELECTRIC COMPANY (San Onofre Nuclear

)

Generating Station, Unit No. 1)

)

CERTIFICATE OF SERVICE I hereby certify that a copy of Amendment Application No. ian_

was served on the following by deposit in the United States Mail, postage prepaid, on the 5th day of July

, 1990.

David R. Pigott, Esq.

Samuel B. Casey, Esq.

Orrick, Herrington & Sutcliffe 600 Montgomery Street San Francisco, California 94111 Charles W. Lacey Senior Vice President Bechtel Power Corporation 12440 East Imperial Highway Norwalk, California 90650 Michael L. Mellor, Esq.

Thelen, Marrin, Johnson & Bridges Two Embarcadero Center San Francisco, California 94111 Huey Johnson Secretary for Resources State of California 1416 Ninth Street Sacramento, California 95814 Janice E. Kerr, General Counsel California Public Utilities Commission 5066 State Building San Francisco, California 94102

S S

-2 C.

J.

Craig Manager U.S. Nuclear Projects I ESSD Westinghouse Electric Corporation Post Office Box 355 Pittsburgh, Pennsylvania 15230 A. I. Gaede 23222 Cheswald Drive Laguna Niguel, California 92677 Frederick E. John, Executive Director California Public Utilities Commission 5050 State Building San Francisco, California 94102