Proposed Tech Specs Removing 3.25 Surveillance Limit from Spec 4.0.2
ML13331A430
Person / Time
Site: San Onofre 
Issue date: 06/11/1990
From:
SOUTHERN CALIFORNIA EDISON CO.
To:
Shared Package
ML13331A428 List:
References
NUDOCS 9006140197
Download: ML13331A430 (3)


Text

ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATIONS

-7,001-4C)1-17 9006AI11 FDR pniCKO5O2c)

P:

4.0 SURVEILLANCE REQUIREMENTS (GENERAL)

APPLICABILITY:

Applies to the surveillance requirements to be implemented in these specifications.

OBJECTIVE:

To define the conditions under which the surveillance requirements of Section 4 Specifications are applicable.

SPECIFICATION:

4.0.1 Surveillance Requirements shall be met during the OPERATIONAL MODES or other conditions specified for individual Limiting Conditions for Operation unless otherwise stated in an individual Surveillance Requirement.

4.0.2 Each Surveillance Requirement shall be performed within the specified surveillance interval with a maximum allowable extension not to exceed 25% of the specified surveillance interval.

4.0.3 Failure to perform a Surveillance Requirement within the specified time interval shall constitute a failure to meet the OPERABILITY requirements for a Limiting Condition for Operation. Exceptions to these requirements are stated in the individual Specifications. Surveillance Requirements do not have to be performed on inoperable equipment.

4.0.4 Entry into an OPERATIONAL MODE or other specified condition shall not be made unless the Surveillance Requirement(s) associated with the Limiting Condition for Operation have been performed within the stated surveillance interval or as otherwise specified.

BASIS:

Specification 4.0.1 provides that surveillance activities necessary to insure the Limiting Conditions for Operation are met and will be performed during the OPERATIONAL MODES or other conditions for which the limiting Conditions for Operation are applicable. Provisions for additional surveillance activities to be performed without regard to the applicable OPERATIONAL MODES or other conditions are provided in the individual Surveillance Requirements. Surveillance Requirements for, Special Test Exceptions need only be performed when the Special Test Exception is being utilized as an exception to an individual specification.

SAN ONOFRE - UNIT 1 4.0-1 AMENDMENT NO:

83, 130

Specification 4.0.2 establishes the limit for which the specified time interval for Surveillance Requirements may be extended. It permits an allowable extension of the normal surveillance interval to facilitate surveillance scheduling and consideration of plant operating conditions that may not be suitable for conducting the surveillance; e.g., transient conditions or other ongoing surveillance or maintenance activities. It also provides flexibility to accommodate the length of a fuel cycle for surveillances that are performed at each refueling outage and are specified with an 18-month surveillance interval.

It is not intended that this provision be used repeatedly as a convenience to extend surveillance intervals beyond that specified for surveillances that are not performed during refueling outages. The limitation of specification 4.0.2 is based on engineering judgment and the recognition that the most probable result of any particular surveillance being performed is the verification of conformance with the Surveillance Requirements. This provision is sufficient to ensure that the reliability ensured through surveillance activities is not significantly degraded beyond that obtained from the specified surveillance interval.

The provisions of specification 4.0.3 set forth the criteria for determination of compliance with the OPERABILITY requirements of the Limiting Conditions for Operation. Under this criteria, equipment, systems or components are assumed to be OPERABLE if the associated surveillance activities have been satisfactorily performed within the specified time interval.

Nothing in this provision is to be construed as defining equipment, systems or components, OPERABLE, when such items are found or known to be inoperable although still meeting the Surveillance Requirements.

Specification 4.0.4 ensures that the surveillance activities associated with a Limiting Condition for Operation have been performed within the specified time interval prior to entry into an, OPERATIONAL MODE or other applicable condition. The intent of this provision is to ensure that surveillance activities have been satisfactorily demonstrated on a current basis as required to meet the OPERABILITY requirements of the Limiting Condition for Operation.

Under the terms of this specification, for example, during initial plant startup or following extended plant outages, the applicable surveillance activities must be performed within the stated surveillance interval prior to placing or returning the system or equipment into OPERABLE status.

SAN ONOFRE - UNIT 1 4.0-2 AMENDMENT NO:

83, 130