NOTICE OF VIOLATION Southern California Edison Company Docket No.
50-361 San Onofre Unit 2 License No. NPF-10 During an NRC inspection conducted on December 1, 1992 through January 8, 1993, a violation of NRC requirements was identified. In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C, the violation is listed below:
A. Technical Specification 6.8.1 for San Onofre Nuclear Generating Station, Unit 2, requires that written procedures shall be established, implemented and maintained covering activities referenced in Appendix A of Regulatory Guide 1.-33, Revision 2. Appendix A of Regulatory Guide 1.33, Revision 2, specifies that safety related activities should be covered by written procedures, including procedures for access control to radiation areas including a radiation work permit system.
Section 6.3.2 of procedure S0123-VII-9.9, TCN 11-3, "Radiation Exposure Permit (REP) Program," requires that, "all personnel covered by the REP shall follow the requirements specified in the REP."
Revision 16 to REP-00700, "Visual Inspection; All Areas Except Containments," requires that the following protective clothing be worn for entry into contaminated areas: coveralls, cloth hood, rubber gloves, and cordero covers.
Contrary to the above, on December 17, 1992, Station Technical personnel entered a contaminated area surrounding Unit 2 High Pressure Safety Injection pump P017 to perform an inservice test without wearing the necessary protective clothing specified by the REP.
This is a Severity Level IV violation (Supplement IV) applicable to Unit
- 2.
Pursuant to the provisions of 10 CFR 2.201, Southern California Edison Company is hereby required to submit a written statement or explanation to the U.S.
Nuclear Regulatory Commission, ATTN:
Document Control Desk, Washington, DC 20555 with a copy to the Regional Administrator, Region V, and a copy to the NRC Senior Resident Inspector, San Onofre Nuclear Generating Station, within 30 days of the date of the letter transmitting this Notice. This reply should be clearly marked as a "Reply to a Notice of Violation" and should include for each violation: (1) the reason for the violation, or, if contested, the basis for disputing the violation, (2) the corrective steps that have been taken and the results achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the date when full compliance will be achieved.
If an adequate reply is not received within the time specified in this Notice, the Commission may issue an order or a demand for information as to why the 9302180063 930126 PDR ADOCK 05000206 Q
2 license should not be modified, suspended, or revoked or why such other action as may be proper should not be taken. Where good cause is shown consideration will be given to extending the response time.
Dated at Walnut Creek, California this 2(.."day of
'.s