Forwards Application for Amend to License DPR-13,consisting of Amend Application 198,revising TS Section 3.2, Chemical & Vol Control Sys to Reflect Increase in Amount of Trisodium Phosphate Stored in Containment Racks
ML13326A811
Person / Time
Site: San Onofre 
Issue date: 09/17/1991
From: Ray H
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML13326A812 List:
References
NUDOCS 9109190218
Download: ML13326A811 (2)


Text

Southern California Edison Company 23 PARKER STREET IRVINE, CALIFORNIA 92718 HAROLD B. RAY TELEPHONE SENIOR VICE PRESIDENT 714-458-4400 September 17, 1991 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:

Subject:

Docket No. 50-206 Amendment Application No. 198 San Onofre Nuclear Generating Station Unit 1

Reference:

Letter, F. R. Nandy, SCE to NRC, "Post Accident pH in Containment Sump," February 27, 1991 Enclosed is Amendment Application No. 198 to the Provisional Operating License DPR-13 for San Onofre Nuclear Generating Station, Unit 1. Amendment Application No. 198 consists of Proposed Change No. 244.

Proposed Change No. 244 is a request to revise Appendix A, Technical Specifications Section 3.2, "Chemical and Volume Control System"; Section 3.3.1, "Operating Status" for Safety Injection and Containment Spray Systems; Section 3.3.3, "Minimum Boron Concentration in the Refueling Water Storage Tank (RWST) and Safety Injection (SI) Lines and Minimum RWST Water Volume";

and Section 4.2.1, "Safety Injection and Containment Spray System Periodic Testing." A new Technical Specification Section 3.3.6, "Trisodium Phosphate (TSP) in the Containment Racks" is to be created.

The proposed change reflects an increase in the amount of trisodium phosphate (TSP) stored in the containment racks and incorporates into the Technical Specifications new limits for total boron inventory in the Reactor Coolant System, the RWST and the Boric Acid Storage Tank (BAST).

The proposed change is necessary due to changes in our calculations which now include the BAST, in addition to the RWST, as a potential source of borated water in the containment following design basis accidents. The BAST was not included in previous calculations that established Technical Specification limits for TSP and boron concentration in RWST and BAST.

Administrative controls have been implemented at SONGS 1 to ensure that the post-accident containment water pH is maintained within the limits required by the Technical Specifications. These controls are discussed in detail in the above-referenced letter. The proposed change, once approved, will supplant the administrative controls.

PEIR ADO CK O5O(D2

_P_PD

Administrative controls have been implemented at SONGS 1 to ensure that the post-accident containment water pH is maintained within the limits required by the Technical Specifications. These controls are discussed in detail in the above-referenced letter. The proposed change, once approved, will supplant the administrative controls.

If you have any comments or questions regarding this amendment application, please call me.

Very truly yours, Enclosure cc:

George Kalman, NRC Senior Project Manager, San Onofre Unit 1 J. 0. Bradfute, NRC Project Manager, San Onofre Unit 1 J. B. Martin, Regional Administrator, NRC Region V C. W. Caldwell, NRC Senior Resident Inspector, San Onofre Units 1, 2, & 3