Text
G-1
,tREGL,
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION V
1990 N. CALIFORNIA BOULEVARD
SUITE 202, WALNUT CREEK PLAZA
WALNUT CREEK, CALIFORNIA 94596
MY 23 lk
Docket No. 50-206
Southern California Edison Company
P. 0. Box 800
2244 Walnut Grove Avenue
Rosemead, California 91770
Attention:
Dr. L. T. Papay, Vice President
Advanced Engineering
Gentlemen:
Subject: NRC Investigation at San Onofre Unit 1
This refers to the investigation conducted by Messrs. Joukoff and North of
this office on April 23-25, 1980 of activities authorized by NRC License
No. DPR-13, and to the discussion of our findings held by Mr. North with
Mr. Curran and other members of your staff at the conclusion of the investigation.
The investigation was an examination of certain allegations made with
respect to radiation protection practices at San Onofre Unit 1. Within
these areas, the investigation consisted of selective examinations of
procedures and representative records, interviews with personnel, and
observations by the inspectors.
Based on the results of this investigation, it appears that one of your
activities was not conducted in full compliance with NRC requirements,
as set forth in the Notice of Violation, enclosed herewith as Appendix A.
This item of noncompliance has been categorized into a level as described
in our correspondence to all NRC licensees dated December 31, 1974.
This notice is sent to you pursuant to the provisions of Section 2.201,
of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal
Regulations. Section 2.201 requires you to submit to this office,
within twenty (20) days of your receipt of this notice, a written statement
or explanation in reply including (1) corrective steps which have been
taken by you and the results achieved; (2) corrective steps which will
be taken to avoid further violations; and (3) the date when full compliance
will be achieved.
soori1o Pl
.Southern California Edison Company
-2-
MAY 2; 4
'
In accordance with Section 2.790 of the NRC's "Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter and
the enclosed investigation report will be placed in the NRC's Public
Document Room. If this report contains any information that you believe
to be proprietary, it is necessary that you submit a written application
to this office, within 20 days of the date of this letter, requesting
that such information be withheld from public disclosure. The application
must include a full statement of the reasons why it is claimed that the
information is proprietary. The application should be prepared so that
any proprietary information identified is contained in an enclosure to
the application, since the application without the enclosure will also
be placed in the Public Document Room. If we do not hear from you in
this regard within the specified period, the report will be placed in
the Public Document Room.
Should you have any questions concerning this investigation, we will be
glad to discuss them with you.
Sincerely,
H. E. Book, Chief
Fuel Facility and Materials
Safety Branch
A. Appendix A - Notice of Violation
B. IE Investigation Report
No. 50-206/80-13
cc w/o enclosure B:
R. Dietch, Vice President
Nuclear Engineering and Operations, SCE