Requests Addl Info Re 881229 Amend Application 161, Concerning Increased Surveillance Intervals for Reactor Protection Sys Testing Re Containment Spray Actuation Instrumentation,Including Confirmation of Methodology
ML13316B423
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 10/31/1989
From: Trammell C
Office of Nuclear Reactor Regulation
To: Ray H
Southern California Edison Co
References
TAC-71806 NUDOCS 8911130281
Download: ML13316B423 (4)


Text

-

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 October 31, 1989 Docket No. 50-206 Mr. Harold B. Ray Vice President Southern California Edison Company Irvine Operations Center 23 Parker Irvine, California 92718 Dedr Mr. Ray:

SUBJECT:

AMENDMENT APPLICATION 161 REGARDING INCREASED SURVEILLANCE INTERVALS FOR RPS TESTING FOR SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 1 (TAC NO. 71806)

In reviewing your Amendment Application 161 dated December 29, 1988, regarding containment spray actuation instrumentation, we have determined that the following additional information is needed to continue our review. In order to maintain our review schedule, your response is requested within 90 days of your receipt of this letter.

Rkquest for Additional Information 1.' In addressing the NRC's imposed conditions for acceptance of these changes to the Technical Specifications, you have failed to confirm that the instrument setpoint methodology includes sufficient adjustments to offset the drift anticipated as a result of less frequent surveillance. At this time, you should have sufficient data to draw a conclusion as to whether or not the current set point allowance also conservatively bounds anticipated drift over a quarterly surveillance interval. A review of "as found" and "as left" data from prior surveillance should be completed in order to confirm that sufficient adjustments will be made to offset quarterly drift.

2. Your proposed Action 2 for Reactor Trip System Instrumentation in table 3.5.1-1 is not consistent with the description of changes on page 2 of the application. You have proposed to change Action 2 part (a) to read " The inoperable channel is placed in the tripped condition within six hours". This change, from one to six hours, is not reflected in the Description of Changes. Please indicate this change on the Description of Changes, or provide an alternate Action 2, in which part (a) would not be changed, for incorporation to the Technical Specification.

OFa!

8911130281 891031 PDR ADOCK 05000206 P

PNU)

Mr. Harold October 31, 1989

3. On page 2 of your Amendment Application, it is stated that there are no changes to the Existing Technical Specification for "Power Range, Neutron Flux, Overpower Trip". This is inaccurate, as the corresponding action statement for this functional unit in table 3.5.1-1 is Action 2. You have requested to change Action 2, dnd, therefore, there is a change to the existing Technical Specification. This change should be noted in the description of changes in your application.
4. In table 4.1.1 of the proposed Technical Specification note #7 has been added to the table notation. This note is not referenced anywhere on table 4.1.1. Please remove this note from the table notation of your proposed Technical Specifications if it will not be referenced. Otherwise, change table 4.1.1 accordingly to incorporate this notation.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is riot required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

October 31, 1989 Mr. Harold B. Ray

- 2

3. On page 2 of your Amendment Application, it is stated that there are no changes to the Existing Technical Specification for "Power.Range, Neutron Flux, Overpower Trip". This is inaccurate, as the corresponding action statement for this functional unit in table 3.5.1-1 is Action 2. You have requested to change Action 2, and, therefore, there is a change to the existing Technical Specification. This change should be noted in the description of changes in your application.
4. In table 4.1.1 of the proposed Technical Specification note #7 has been added to the table notation. This note is not referenced anywhere on table 4.1.1. Please remove this note from the table notation of your proposed Technical Specifications if it will not be referenced. Otherwise, change table 4.1.1 accordingly to incorporate this notation.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, original signed by Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects cc:

w/enclosure:

See next page DISTRIBUTION Docket File CTrammell NRC & LPDRs-OGC PDV Reading EJordan MVirgilio Bwadame JZwolinski ACRS (10)

AD/Region FC V

DR P/PV
DV IAME

.rammell

AA
sg
G ighton :

ATE :105 /89

10

/89

10/

/89 OFFICIAL RECORD COPY Document Name: AMENDMENT APPLICATION 161

Mr. Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc David R. Pigott Mr. F. B. Marsh, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street P. 0. Box 60860 San Francisco, California 94111 Terminal Annex Los Angeles, California 90060 Mr. Robert G. Lacy Manager, Nuclear San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific highway Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don Womeldorf Chief Environmental Management California Department of Health 714 P Street, Room 616 Sacramento, California 95814