Forwards Amend 109 to License DPR-13,safety Evaluation & Notice of Issuance.Amend Revises Control Room Emergency Air Treatment Sys Surveillance Requirements to Include Testing w/newly-added Duct Heaters
ML13316B118
Person / Time
Site: San Onofre 
Issue date: 09/26/1988
From: Trammell C
Office of Nuclear Reactor Regulation
To: Baskin K
Southern California Edison Co
Shared Package
ML13316B119 List:
References
TAC-65857 NUDOCS 8810110308
Download: ML13316B118 (7)


Text

September 26, 1988 Docket No. 50-206 DISTRIBUTION Docket Fie (50-206)

NRC & LPDRs BGrimes Mr. Kenneth P. Baskin PD5 Reading TBarnhart (4)

Vice President GHolahan EButcher Southern California Edison Company JLee ACRS (10) 2244 Walnut Grove Avenue OGC-WF GPA/PA Post Office Box 800 DHagan ARM/LFMB Rosemead, California 91770 EJordan WJones CTrammell CNichols

Dear Mr. Baskin:

SUBJECT:

ISSUANCE OF AMENDMENT NO.109 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 65857)

The Commission has issued the enclosed Amendment No.109 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated May 27, 1987.

The amendment revises the Control Room Emergency Air Treatment System surveil lance requirements to (1) include testing with the newly-added duct heaters and (2) more closely follow the Standard Technical Specifications and current regulatory guidance for charcoal filter surveillance. The amendment also allows for suspension of pressurizer power-operated relief valve (PORV) block valve exercising during periods when the block valve is closed due to an inoperable PORV.

A copy of our related Safety Evaluation is also enclosed. The enclosed related Notice of Issuance has been forwarded to the Office of the Federal Register for publication.

Sincerely, original signed by Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

1. Amendment No. 109 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclosures:

See next page DFJ/PD5

/PD5 OGCW-127/o DRSP/D:PD5 UTammell:dr I

LeW GWKnighton

/88 q /

V88

,///88

/

88 OFFICIAL RECORD COPY 8S10110308 SSO926 PDR ADOCK 05000206 P

PDC

September 26, 1988 Docket No. 50-206 DISTRIBUTION Docket File (50-206)

NRC & LPDRs BGrimes Mr. Kenneth P. Baskin PD5 Reading TBarnhart (4)

Vice President GHolahan EButcher Southern California Edison Company JLee ACRS (10) 2244 Walnut Grove Avenue OGC-WF GPA/PA Post Office Box 800 DHagan ARM/LFMB Rosemead, California 91770 Edordan Wdones CTrammell CNichols

Dear Mr. Baskin:

SUBJECT:

ISSUANCE OF AMENDMENT NO. 109 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 65857)

The Commission has issued the enclosed Amendment No.109 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated May 27, 1987.

The amendment revises the Control Room Emergency Air Treatment System surveil lance requirements to (1) include testing with the newly-added duct heaters and (2) more closely follow the Standard Technical Specifications and current regulatory guidance for charcoal filter surveillance.

The amendment also allows for suspension of pressurizer power-operated relief valve (PORV) block valve exercising during periods when the block valve is closed due to an inoperable PORV.

A copy of our related Safety Evaluation is also enclosed. The enclosed related Notice of Issuance has been forwarded to the Office of the Federal Register for publication.

Sincerely, original signed by Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects

III, IV, V and Special Projects

Enclosures:

1. Amendment No. 109 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/eSnclosures:

See next page7 CharlseM.lramme GWSnighonrjc aae PD I

/PD5 OG C&'7' DRSP/D:PD5 1 a

~m ie 1 rojec Di rctrat VWng 11 1/88 U8

/88/V88 OFFICIAL RECORD COPY

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 September 26, 1988

  • d cket No. 50-206 Mr. Kenneth P. Baskin Vice President Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770

Dear Mr. Baskin:

SUBJECT:

ISSUANCE OF AMENDMENT NO.109 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 65857)

The Commission has issued the enclosed Amendment No.109 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated May 27, 1987.

The amendment revises the Control Room Emergency Air Treatment System surveil lance requirements to (1) include testing with the newly-added duct heaters and (2) more closely follow the Standard Technical Specifications and current regulatory guidance for charcoal filter surveillance. The amendment also allows for suspension of pressurizer power-operated relief valve (PORV) block valve exercising during periods when the block valve is closed due to an inoperable PORV.

A copy of our related Safety Evaluation is also enclosed. The enclosed related Notice of Issuance has been forwarded to the Office of the Federal Register for publication.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

Enclosures:

1. Amendment No.109 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclosures:

See next page

Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Mr. Jack McGurk, Acting Chief General Counsel Radiological Health Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office Bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Mr. Hans Kaspar, Executive Director Orrick, Herrington & Sutcliffe Marine Review Committee, Inc.

600 Montgomery Street 531 Encinitas Boulevard, Suite 105 San Francisco, California 94111 Encinitas, California 92024 Mr. Robert G. Lacy Mr. Dennis M. Smith, Chief Manager, Nuclear Radiological Programs Division San Diego Gas & Electric Company Governor's Office of Emergency Svcs.

P. 0. Box 1831 State of California San Diego, California 92112 2800 Meadowview Road Sacramento, California 95832 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596

REDIS*UTED: OCTOBER 11, 1988 September 26, 1988 Docket No. 50-206 DISTRIBUTION Do -cket File (50-206)

NRC & LPDRs -

BGrimes Mr. Kenneth P. Baskin PD5 Reading TBarnhart (4)

Vice President GHolahan EButcher Southern California Edison Company

--JLee ACRS (10) 2244 Walnut Grove Avenue OGC-WF GPA/PA Post Office Box 800 DHagan ARM/LFMB Rosemead, California 91770 EJordan Wones CTrammuell CNichols

Dear Mr. Baskin:

SUBJECT:

ISSUANCE OF AMENDMENT NO. 109 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 65857)

The Commission has issued the enclosed Amendment No.109 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated May 27, 1987.

The amendment revises the Control Room Emergency Air Treatment System surveil lance requirements to (1) include testing with the newly-added duct heaters and (2) more closely follow the Standard Technical Specifications and current regulatory guidance for charcoal filter surveillance.

The amendment also allows for suspension of pressurizer power-operated relief valve (PORV) block valve exercising during periods when the block valve is closed due to an inoperable PORV.

A copy of our related Safety Evaluation is also enclosed. The enclosed related Notice of Issuance has been forwarded to the Office of the Federal Register for publication.

Sincerely, oriinal signed by Charles M. Trammiell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

Enclosures:

1. Amendment No. 109 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclosures:S See next page\\

4 /

I DJ /P5 b"/PD5 OGCt2IYA DRSP/D:PD5 ChrlsaM aell:dr mSm4L el GWKnighton

/88

< P 1,/88

/88 l

8 OFFICIAL RECORD COPY 1Y m9 to

STRIBUTED: OCTOBER 11, 1988 UNITED STATES 0

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 September 26, 1988 ocket No. 50-206 Mr. Kenneth P. Baskin Vice President Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770

Dear Mr. Baskin:

SUBJECT:

ISSUANCE OF AMENDMENT NO.109 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 65857)

The Commission has issued the enclosed Amendment No.109 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated May 27, 1987.

The amendment revises the Control Room Emergency Air Treatment System surveil lance requirements to (1) include testing with the newly-added duct heaters and (2) more closely follow the Standard Technical Specifications and current regulatory guidance for charcoal filter surveillance. The amendment also allows for suspension of pressurizer power-operated relief valve (PORV) block valve exercising during periods when the block valve is closed due to an inoperable PORV.

A copy of our related Safety Evaluation is also enclosed. The enclosed related Notice of Issuance has been forwarded to the Office of the Federal Register for publication.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

Enclosures:

1. Amendment No.109 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclosures:

See next page

Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Mr. Jack McGurk, Acting Chief General Counsel Radiological Health Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office Bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Mr. Hans Kaspar, Executive Director Orrick, Herrington & Sutcliffe Marine Review Committee, Inc.

600 Montgomery Street 531 Encinitas Boulevard, Suite 105 San Francisco, California 94111 Encinitas, California 92024 Mr. Robert G. Lacy Mr. Dennis M. Smith, Chief Manager, Nuclear Radiological Programs Division San Diego Gas & Electric Company Governor's Office of Emergency Svcs.

P. 0. Box 1831 State of California San Diego, California 92112 2800 Meadowview Road Sacramento, California 95832 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596