Forwards SER Accepting Proposed Testing Schedule & Alternate Method for Verifying Valve Operability as Proposed by VRR 3 & 13
ML13302B829
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 03/11/1992
From: Quay T
Office of Nuclear Reactor Regulation
To: Cotton G, Ray H
Shared Package
ML13302B830 List:
References
TAC-M81947, TAC-M81948, NUDOCS 9203180248
Download: ML13302B829 (3)


Text

.

March 11, 1992 Docket Nos. 50-361 and 50-362 Mr. Harold B. Ray Mr. Gary D. Cotton Senior Vice President Senior Vice President Southern California Edison Company Engineering and Operations Irvine Operations Center San Diego Gas & Electric Co.

23 Parker Street 101 Ash Street Irvine, California 92718 San Diego, California 92112 Gentlemen:

SUBJECT:

INSERVICE TESTING PROGRAM FOR PUMPS AND VALVES AT SAN ONOFRE UNITS 2 AND 3 (TAC NOS. M81947 AND M81948)

The NRC staff review of the San Onofre Nuclear Generating Station Inservice Testing Program (IST) for Pumps and Valves at Units 2 and 3 is documented by Safety Evaluation Reports dated September 24, 1990, and October 2, 1991.

Our Safety Evaluation Report dated September 24, 1990, granted interim relief from the IST program for containment sump check valves 24-003-C-724 and 24-004-C-724 and for containment spray check valves 8-004-C-406 and 8-006-C-406. By letter dated October 28, 1991, the Southern California Edison Company provided additional information to support the relief requests for these valves, VRR Nos. 3 and 13, and to make them a permanent part of the IST program for Units 2 and 3.

The enclosed Safety Evaluation Report concludes that the proposed testing schedule and the alternate method for verifying valve operability as proposed by VRR Nos. 3 and 13 is acceptable. These relief requests are hereby granted.

Sincerely, iginal Signed By: Harry Rood heodore R. Quay, Director Project Directorate V Division of Reactor Projects III/IV/V Office of Nuclear Reactor.Regulation

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DISTRIBUTION:

Dc File]

NRC/Local PDRs PDV r/f BBoger MVirgilio TQuay DFoster JBradfute GKalman OGC(15B18)

ACRS(10)(P315)

RZimmerman,RV PDV p/f OFC PDV/LA

PDV/PM PDV/D NAME DFoster
G an TQuay DATE

/1/92 l3 /a'92

-3

/92 Document Name:

IST81947.LTR 9203180248 920311 PDR ADOCK 05000361 PDPDRV T~uay

00 0

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 11, 1992 Docket Nos. 50-361 and 50-362 Mr. Harold B. Ray Mr. Gary D. Cotton Senior Vice President Senior Vice President Southern California Edison Company Engineering and Operations Irvine Operations Center San Diego Gas & Electric Co.

23 Parker Street 101 Ash Street Irvine, California 92718 San Diego, California 92112 Gentlemen:

SUBJECT:

INSERVICE TESTING PROGRAM FOR PUMPS AND VALVES AT SAN ONOFRE UNITS 2 AND 3 (TAC NOS. M81947 AND M81948)

The NRC staff review of the San Onofre Nuclear Generating Station Inservice Testing Program (IST) for Pumps and Valves at Units 2 and 3 is documented by Safety Evaluation Reports dated September 24, 1990, and October 2, 1991.

Our Safety Evaluation Report dated September 24, 1990, granted interim relief from the IST program for containment sump check valves 24-003-C-724 and 24-004-C-724 and for containment spray check valves 8-004-C-406 and 8-006-C-406. By letter dated October 28, 1991, the Southern California Edison Company provided additional information to support the relief requests for these valves, VRR Nos. 3 and 13, and to make them a permanent part of the IST program for Units 2 and 3.

The enclosed Safety Evaluation Report concludes that the proposed testing schedule and the alternate method for verifying valve operability as proposed by VRR Nos. 3 and 13 is acceptable. These relief requests are hereby granted.

Sincerely, Theodore R. Quay, Director Project Directorate V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/enclosure:

See next page

Messrs. Ray and Cotton San Onofre Nuclear Generating Southern California Edison Company Station, Unit Nos. 2 and 3 cc:

James A. Beoletto, Esq.

Mr. Richard J. Kosiba, Project Manager Southern California Edison Company Bechtel Power Corporation Irvine Operations Center 12440 E. Imperial Highway 23 Parker Street Norwalk, California 90650 Irvine, California 92718 Mr. Robert G. Lacy Chairman, Board of Supervisors Manager, Nuclear Department County of San Diego San Diego Gas & Electric Company 1600 Pacific Highway, Room 335 P. 0. Box 1831 San Diego, California 92101 San Diego, California 92112 Alan R. Watts, Esq.

Mr. John Hickman Rourke & Woodruff Senior Health Physicist 701

1.

Parker St. No. 7000 Environmental Radioactive Mgmt. Unit Orange, California 92668-4702 Environmental Management Branch State Department of Health Services Mr. Sherwin Harris 714 P Street, Room 616 Resource Project Manager Sacramento, California 95814 Public Utilities Department City of Riverside Resident Inspector/San Onofre NPS 3900 Main Street cSo U.S. Nuclear Regulatory Commission Riverside, California 92522 Post Office Box 4329 San Clemente, California 92674 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations ABS Combustion Engineering Nuclear Power Mayor 12300 Twinbrook Parkway, Suite 330 City of San Clemente Rockville, Maryland 20852 100 Avenida Presidio San Clemente, California 92672 Mr. Phil Johnson Regional Administrator, Region V U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Walnut Creek, California 94596 Mr. Don J. Womeldorf Chief, Environmental Management Branch California Department of Health Services 714 P Street, Room 616 Sacramento, California 95814